{{#Wiki_filter:SAFEGUARDS | {{#Wiki_filter:SAFEGUARDS INFORMATION June 15, 2006 EA 06-116 EA 06-117 Mr. Theodore Sullivan Site Vice President - Vermont Yankee Entergy Nuclear Vermont Yankee, LLC P.O. Box 0500 185 Old Ferry Road Brattleboro, VT 05302-0500 | ||
==SUBJECT:== | ==SUBJECT:== | ||
ISSUANCE OF ORDERS FOR INTERIM SAFEGUARDS AND | ISSUANCE OF ORDERS FOR INTERIM SAFEGUARDS AND SECURITY COMPENSATORY MEASURES AND FOR IMPLEMENTATION OF ADDITIONAL SECURITY MEASURES ASSOCIATED WITH ACCESS AUTHORIZATION FOR VERMONT YANKEE NUCLEAR POWER STATION INDEPENDENT SPENT FUEL STORAGE INSTALLATION | ||
==Dear Mr. Thayer:== | ==Dear Mr. Thayer:== | ||
The U.S. Nuclear Regulatory Commission (NRC or the Commission) has issued the enclosed Orders (Enclosures 1 and 3) which modify the general license for your independent spent fuel storage installation (ISFSI), to require compliance with the specified: interim compensatory measures (ICMs) for security and safeguards (Enclosure 2)(Attachment 1 to ); and additional security measures (ASMs) associated with access authorization (Enclosure 4)(Attachment 1 to Enclosure 3). Enclosure 5 is an NRC Regulatory Information Summary regarding the NRC Threat Advisory and Protective Measures System for ISFSIs. | |||
Enclosures 2, 4, and 5 contain Safeguards Information (SGI). | |||
The Commission has determined that additional security measures are required, since the events of September 11, 2001, and has concluded that the security measures should be embodied in Orders, consistent with the established regulatory framework. The requirements of the enclosed Orders must be in place before first receipt of spent fuel and initial operations at your ISFSI. | |||
SAFEGUARDS INFORMATION WARNING: Violation of Section 147 of the Atomic Energy Act, "Safeguards Information," | |||
is subject to Civil and Criminal Penalties. | |||
NOTICE: Upon removal of Enclosures 2, 4, and 5 to the Letter, this document and the enclosed Orders (Enclosures 1 and 3) are DECONTROLLED. | |||
SAFEGUARDS INFORMATION T. Sullivan The Orders do not obviate the need for licensees to continue to meet and maintain the effectiveness of existing security measures taken in response to the events of September 11, 2001. The requirements will remain in effect until the Commission determines otherwise. | |||
SAFEGUARDS | The enclosed Orders call for responses and actions within specified time frames. With respect to the notices and submission required by Sections III.B and III.C of the Orders, for any requirement of the ICMs or ASMs (SGI attachments to the Orders) that requires an analysis or is contingent on completion of another requirement of the ICMs or ASMs, it will be a sufficient response if the licensee states in its 20-day submission: | ||
(1) | |||
SAFEGUARDS INFORMATION SAFEGUARDS | That completion of the requirement depends upon completion of an analysis or other requirement; (2) | ||
The expected date of completion of the analysis or other requirement; and, (3) | |||
That, on such completion, the licensee will promptly submit the results of such analysis or inform NRC of the completion of the other requirement and the actions thereafter proposed, with respect to the requirement at issue, as well as the projected date of completion. | |||
If Entergy Nuclear Vermont Yankee, LLC wishes to preserve its right to request a hearing on any requirement, contingent on completion of an analysis or other requirement, a request for an extension of time to request a hearing must be filed within 20 days of the date of these Orders, in accordance with Section IV of the Orders. Such a request may seek a reasonable period of time to request a hearing beyond the date that the staff informs the licensee whether the actions proposed and completion date for the requirement(s), contingent on an analysis or other requirement, are satisfactory. | |||
Please note that letters of response to Sections III.B and III.C of the Orders should be addressed to the ATTN: Document Control Desk, Director, Spent Fuel Project Office, Office of Nuclear Material Safety and Safeguards. Answers to the Orders should be addressed to the Secretary, Office of the Secretary of the Commission, as stated in Section IV of the Orders. | |||
Please contact Paul J. Kelley, Jr., at 301-415-6101, for the ICM Order, or Bradley Baxter, at 301-415-6742, for the ASM Order, in the Office of Nuclear Security and Incident Response; or Christopher M. Regan, at 301-415-1179, of my staff, to facilitate resolution of any issues related to compliance with the requirements in the enclosed Orders, or to facilitate answering any other questions you may have. The enclosed Orders have been forwarded to the Office of the Federal Register, for publication. | |||
SAFEGUARDS INFORMATION | |||
SAFEGUARDS INFORMATION T. Sullivan The material in Enclosures 2, 4, and 5 contains SGI, as defined by 10 CFR 73.21, and its disclosure to unauthorized individuals is prohibited by Section 147 of the Atomic Energy Act of 1954, as amended. Therefore, the material will not be made available electronically, for public inspection, in the NRC Public Document Room, or from NRCs Agencywide Documents Access and Management System, accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. | |||
Sincerely, | |||
/RA/ | /RA/ | ||
Jack R. Strosnider, | Jack R. Strosnider, Director Office of Nuclear Material Safety and Safeguards Docket No: | ||
72-59 | |||
==Enclosures:== | ==Enclosures:== | ||
| Line 39: | Line 54: | ||
: 3. ASM Order | : 3. ASM Order | ||
: 4. Attachment 1 to Enclosure 3, ASMs for ISFSI (SGI) | : 4. Attachment 1 to Enclosure 3, ASMs for ISFSI (SGI) | ||
: 5. Regulatory Issue Summary 2002-12D (SGI)cc: | : 5. Regulatory Issue Summary 2002-12D (SGI) cc: w/Enclosures 1 and 3 only, see next page. | ||
SAFEGUARDS INFORMATION SAFEGUARDS | SAFEGUARDS INFORMATION | ||
Jack R. Strosnider, Director Office of Nuclear Material Safety and | SAFEGUARDS INFORMATION T. Sullivan SAFEGUARDS INFORMATION The material in Enclosures 2, 4, and 5 contains SGI, as defined by 10 CFR 73.21, and its disclosure to unauthorized individuals is prohibited by Section 147 of the Atomic Energy Act of 1954, as amended. Therefore, the material will not be made available electronically, for public inspection, in the NRC Public Document Room, or from NRCs Agencywide Documents Access and Management System, accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. | ||
Sincerely, | |||
/RA/ | |||
Jack R. Strosnider, Director Office of Nuclear Material Safety and Safeguards Docket No: 72-59 | |||
==Enclosures:== | ==Enclosures:== | ||
| Line 49: | Line 67: | ||
: 3. ASM Order | : 3. ASM Order | ||
: 4. Attachment 1 to Enclosure 3, ASMs for ISFSI (SGI) | : 4. Attachment 1 to Enclosure 3, ASMs for ISFSI (SGI) | ||
: 5. Regulatory Issue Summary 2002-12D (SGI)cc:w/Enclosures 1 and 3 only, see next page. | : 5. Regulatory Issue Summary 2002-12D (SGI) cc: | ||
DISTRIBUTION | w/Enclosures 1 and 3 only, see next page. | ||
DISTRIBUTION: | |||
NRC File Ctr NMSS r/f NSIR r/f MBurrell, OE RVirgilio, STP RLorson, RI/DRS OEWEB SFPO r/f PKelley, NSIR BMorency, NRR CAnderson, RI/DRP OEMAIL DNS r/f BBaxter, NSIR MMiller, RI/NMSS Robert Price PKG ML061600398 OFFICE: | |||
SFPO E | |||
SFPO:LA C | |||
Tech Ed SFPO:SC OE OGC NAME: | |||
CRegan E. Ziegler EKraus M. Wong MJohnson JGoldberg DATE: | |||
4/26 /06 4/27/06 5/8/06 4/28/06 5/4/06 5/12/06 OFFICE: | |||
D:DNS SFPO:DD SFPO:D NMSS:D NAME: | |||
GTracy WRuland EBrach JStrosnider DATE: | |||
5 /18 /06 6/9/06 6/9/06 6 / 15 /06 C = COVER E = COVER & ENCLOSURE (non-SGI only) | |||
N = NO COPY OFFICIAL RECORD COPY}} | |||
Latest revision as of 08:30, 15 January 2025
| ML061640280 | |
| Person / Time | |
|---|---|
| Site: | Vermont Yankee File:NorthStar Vermont Yankee icon.png |
| Issue date: | 06/15/2006 |
| From: | Strosnider J Office of Nuclear Material Safety and Safeguards |
| To: | Ted Sullivan Entergy Nuclear Vermont Yankee |
| Regan C NMSS/SFPO (301) 415-1179 | |
| Shared Package | |
| ML061600398 | List: |
| References | |
| EA-06-116, EA-06-117 | |
| Download: ML061640280 (5) | |
Text
SAFEGUARDS INFORMATION June 15, 2006 EA 06-116 EA 06-117 Mr. Theodore Sullivan Site Vice President - Vermont Yankee Entergy Nuclear Vermont Yankee, LLC P.O. Box 0500 185 Old Ferry Road Brattleboro, VT 05302-0500
SUBJECT:
ISSUANCE OF ORDERS FOR INTERIM SAFEGUARDS AND SECURITY COMPENSATORY MEASURES AND FOR IMPLEMENTATION OF ADDITIONAL SECURITY MEASURES ASSOCIATED WITH ACCESS AUTHORIZATION FOR VERMONT YANKEE NUCLEAR POWER STATION INDEPENDENT SPENT FUEL STORAGE INSTALLATION
Dear Mr. Thayer:
The U.S. Nuclear Regulatory Commission (NRC or the Commission) has issued the enclosed Orders (Enclosures 1 and 3) which modify the general license for your independent spent fuel storage installation (ISFSI), to require compliance with the specified: interim compensatory measures (ICMs) for security and safeguards (Enclosure 2)(Attachment 1 to ); and additional security measures (ASMs) associated with access authorization (Enclosure 4)(Attachment 1 to Enclosure 3). Enclosure 5 is an NRC Regulatory Information Summary regarding the NRC Threat Advisory and Protective Measures System for ISFSIs.
Enclosures 2, 4, and 5 contain Safeguards Information (SGI).
The Commission has determined that additional security measures are required, since the events of September 11, 2001, and has concluded that the security measures should be embodied in Orders, consistent with the established regulatory framework. The requirements of the enclosed Orders must be in place before first receipt of spent fuel and initial operations at your ISFSI.
SAFEGUARDS INFORMATION WARNING: Violation of Section 147 of the Atomic Energy Act, "Safeguards Information,"
is subject to Civil and Criminal Penalties.
NOTICE: Upon removal of Enclosures 2, 4, and 5 to the Letter, this document and the enclosed Orders (Enclosures 1 and 3) are DECONTROLLED.
SAFEGUARDS INFORMATION T. Sullivan The Orders do not obviate the need for licensees to continue to meet and maintain the effectiveness of existing security measures taken in response to the events of September 11, 2001. The requirements will remain in effect until the Commission determines otherwise.
The enclosed Orders call for responses and actions within specified time frames. With respect to the notices and submission required by Sections III.B and III.C of the Orders, for any requirement of the ICMs or ASMs (SGI attachments to the Orders) that requires an analysis or is contingent on completion of another requirement of the ICMs or ASMs, it will be a sufficient response if the licensee states in its 20-day submission:
(1)
That completion of the requirement depends upon completion of an analysis or other requirement; (2)
The expected date of completion of the analysis or other requirement; and, (3)
That, on such completion, the licensee will promptly submit the results of such analysis or inform NRC of the completion of the other requirement and the actions thereafter proposed, with respect to the requirement at issue, as well as the projected date of completion.
If Entergy Nuclear Vermont Yankee, LLC wishes to preserve its right to request a hearing on any requirement, contingent on completion of an analysis or other requirement, a request for an extension of time to request a hearing must be filed within 20 days of the date of these Orders, in accordance with Section IV of the Orders. Such a request may seek a reasonable period of time to request a hearing beyond the date that the staff informs the licensee whether the actions proposed and completion date for the requirement(s), contingent on an analysis or other requirement, are satisfactory.
Please note that letters of response to Sections III.B and III.C of the Orders should be addressed to the ATTN: Document Control Desk, Director, Spent Fuel Project Office, Office of Nuclear Material Safety and Safeguards. Answers to the Orders should be addressed to the Secretary, Office of the Secretary of the Commission, as stated in Section IV of the Orders.
Please contact Paul J. Kelley, Jr., at 301-415-6101, for the ICM Order, or Bradley Baxter, at 301-415-6742, for the ASM Order, in the Office of Nuclear Security and Incident Response; or Christopher M. Regan, at 301-415-1179, of my staff, to facilitate resolution of any issues related to compliance with the requirements in the enclosed Orders, or to facilitate answering any other questions you may have. The enclosed Orders have been forwarded to the Office of the Federal Register, for publication.
SAFEGUARDS INFORMATION
SAFEGUARDS INFORMATION T. Sullivan The material in Enclosures 2, 4, and 5 contains SGI, as defined by 10 CFR 73.21, and its disclosure to unauthorized individuals is prohibited by Section 147 of the Atomic Energy Act of 1954, as amended. Therefore, the material will not be made available electronically, for public inspection, in the NRC Public Document Room, or from NRCs Agencywide Documents Access and Management System, accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
Sincerely,
/RA/
Jack R. Strosnider, Director Office of Nuclear Material Safety and Safeguards Docket No:
72-59
Enclosures:
- 1. ICM Order
- 3. ASM Order
- 5. Regulatory Issue Summary 2002-12D (SGI) cc: w/Enclosures 1 and 3 only, see next page.
SAFEGUARDS INFORMATION
SAFEGUARDS INFORMATION T. Sullivan SAFEGUARDS INFORMATION The material in Enclosures 2, 4, and 5 contains SGI, as defined by 10 CFR 73.21, and its disclosure to unauthorized individuals is prohibited by Section 147 of the Atomic Energy Act of 1954, as amended. Therefore, the material will not be made available electronically, for public inspection, in the NRC Public Document Room, or from NRCs Agencywide Documents Access and Management System, accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
Sincerely,
/RA/
Jack R. Strosnider, Director Office of Nuclear Material Safety and Safeguards Docket No: 72-59
Enclosures:
- 1. ICM Order
- 3. ASM Order
- 5. Regulatory Issue Summary 2002-12D (SGI) cc:
w/Enclosures 1 and 3 only, see next page.
DISTRIBUTION:
NRC File Ctr NMSS r/f NSIR r/f MBurrell, OE RVirgilio, STP RLorson, RI/DRS OEWEB SFPO r/f PKelley, NSIR BMorency, NRR CAnderson, RI/DRP OEMAIL DNS r/f BBaxter, NSIR MMiller, RI/NMSS Robert Price PKG ML061600398 OFFICE:
SFPO E
SFPO:LA C
CRegan E. Ziegler EKraus M. Wong MJohnson JGoldberg DATE:
4/26 /06 4/27/06 5/8/06 4/28/06 5/4/06 5/12/06 OFFICE:
D:DNS SFPO:DD SFPO:D NMSS:D NAME:
GTracy WRuland EBrach JStrosnider DATE:
5 /18 /06 6/9/06 6/9/06 6 / 15 /06 C = COVER E = COVER & ENCLOSURE (non-SGI only)
N = NO COPY OFFICIAL RECORD COPY