r-puhuc service company ce omende | |||
~. | |||
16805 Weld County Road 191/2, Platteville, Colorado 80651 | |||
_c | |||
.i November 30, 1979 Fort St. Vrain Unit No. 1 P-79285 Mr. Karl V. Seyfrit, Director Nuclear Regulatory Commission Region IV Office of Inspection and Enforcement 611 Ryan Plaza Driva Suite 1000 Arlington, Texas 76012 Docket No. 50-267 | |||
r- | |||
_c | |||
Nuclear Regulatory Commission Region IV Office of Inspection and Enforcement 611 Ryan Plaza Driva Suite 1000 Arlington, Texas | |||
==SUBJECT:== | ==SUBJECT:== | ||
| Line 33: | Line 28: | ||
==REFERENCE:== | ==REFERENCE:== | ||
: 1) P-78107 | : 1) P-78107 2) | ||
P-79225 | |||
==Dear Mr. Seyfrit:== | ==Dear Mr. Seyfrit:== | ||
The above referenced letters transmitted to your office information pertaining to System 21 control and instrumentation classes and func-tional test categories. Continued review of the information avail-able indicates that some discrepancies existed in the tables included in the referenced letters. | The above referenced letters transmitted to your office information pertaining to System 21 control and instrumentation classes and func-tional test categories. Continued review of the information avail-able indicates that some discrepancies existed in the tables included in the referenced letters. | ||
The new tables attached reflect changes and additions necessary to update the information for your records. For purposes of clarifica-tion to the tables, Safety-Related Type 3 applies to instruments which must only maintain their pressure boundary following a seismic event. See Attachment 1 for further clarification. | The new tables attached reflect changes and additions necessary to update the information for your records. | ||
For purposes of clarifica-tion to the tables, Safety-Related Type 3 applies to instruments which must only maintain their pressure boundary following a seismic event. See Attachment 1 for further clarification. | |||
If you have any questions, please contact me at (303) 571-7436. | If you have any questions, please contact me at (303) 571-7436. | ||
Very truly yours, | Very truly yours, | ||
& 7Yuudn Don Warembourg v | |||
Manager, Nuclear Production 1706 280 DW/alk 8 0 01090 Et6 | |||
ATTACHMENT 1 The following instrument classes are used: | ATTACHMENT 1 The following instrument classes are used: | ||
Class A - Instruments defined by document 90-SR-6-2, May 12, 1978, as being | Class A - Instruments defined by document 90-SR-6-2, May 12, 1978, as being | ||
" safety related." This safety related classification will extend | |||
"... to components which must function during or following a seismic event," and "... components which must function only following a seismic event." | |||
All these instruments are presently being cali-brated annually under ADM-14 (annual calibration program). | |||
Class B - Instruments presently calibrated annually by plant personnel. | Class B - Instruments presently calibrated annually by plant personnel. | ||
These instruments, along with Class A, are listed on the master calibration schedule. | These instruments, along with Class A, are listed on the master calibration schedule. | ||
Class C - Instruments calibrated by surveillance tests as outlined in the Technical Specifications. | Class C - Instruments calibrated by surveillance tests as outlined in the Technical Specifications. | ||
Class D - Instruments that are not presently calibrated on an annual basis and are used for local indication and/or system performance diag-nosis only. | Class D - Instruments that are not presently calibrated on an annual basis and are used for local indication and/or system performance diag-nosis only. | ||
Class F - Instruments that can't be calibrated because of inaccessibility. | Class F - Instruments that can't be calibrated because of inaccessibility. | ||
| Line 61: | Line 54: | ||
Type 2 - Applies to components which must function only following a seismic event. | Type 2 - Applies to components which must function only following a seismic event. | ||
Type 3 - Applies to instruments which must only maintain their pressure boundary following a seismic event. | Type 3 - Applies to instruments which must only maintain their pressure boundary following a seismic event. | ||
1706 281 | 1706 281 TABLE 1 INSTRUMENT CLASS CHANGES Old New Instrument Class Class Remarks SV-2105 B | ||
A ZI-2105 B | |||
D Oscilloscope used for diagnosis only. | |||
ZI-2106 B | |||
D Oscilloscope used for diagnosis only. | |||
HV-2109-1 A | |||
TABLE 1 INSTRUMENT CLASS CHANGES Old | HV-2109-2 A | ||
ZI-2106 | HV-2110-1 A | ||
HV-2109-1 | HV-2110-2 A | ||
ZI-2111 Change to ZI-2111-1 ZI-2111-1 B | |||
A | ZI-2112-1 B | ||
HV-2110-1 | HV-2115-1 A | ||
HV-2115-2 A | |||
SV-2115 - | |||
Change to ZI-2111-1 ZI-2111-1 | B A | ||
HV-2116-1 A | |||
HV-2116-2 A | |||
Type 3 safety related, on calibration XEP-2135 A | |||
B schedule. | |||
Type 3 safety related, on calibration XEP-2136 A | |||
B schedule. | |||
Type 3 safety related, on calibration XEP-2136 | FE-2141 A | ||
FE-2141 | Flow element, no calibration FI-2141 A | ||
Flow element, no calibration FI-2141 | B Type 3 safety related FE-2142 A | ||
Flow element, no calibration FT-2142 A | |||
FE-2142 | B Type 3 safety related XPS-2142 B | ||
Flow element, no calibration FT-2142 | Power suop1v, no calibration PM-2143-1 3 | ||
Loop 1 oneumatic booster, no calibration PM-2143-2 B | |||
XPS-2142 | Looo 1 pneumatic booster, no calibration 1706 282 TABLE 1 (continued) | ||
Power suop1v, no calibration PM-2143-1 | Old New Instru:xnt Class Class Remarks u | ||
Loop 1 oneumatic booster, no calibration PM-2143-2 | PDIC-2143 lA B | ||
Looo 1 pneumatic booster, no calibration 1706 282 | Tvoe 3 safety related PM-2144-1 B | ||
Loop 2 oneumatic boos ter, no ca14bration PM-2144-2 B | |||
Looo 2 pneu=atic booster, no calibration PDIC-2144 A | |||
B Type 3 safety related LS-2145 A | |||
B Type 3 safety related LS-2146 A | |||
B Tvoe 3 safety related PDT-?l47 A | |||
TABLE 1 (continued) | B Tvoe 3 safety related PDT-2148 A | ||
Old | B Tvoe 3 safety related FE-2151 A | ||
PDIC-2143 | |||
Loop 2 oneumatic boos ter, no ca14bration PM-2144-2 | |||
Looo 2 pneu=atic booster, no calibration PDIC-2144 | |||
LS-2146 | |||
Flow element, no caldbration i | Flow element, no caldbration i | ||
FIC-2151 | FIC-2151 A | ||
A | B f Type 3 safety related FIS-2151 A | ||
B Tvoe 3 safety related HV-2152 A | |||
PDS-2152 | PDS-2152 A | ||
B Tvoe 3 safety related HV-2153-1 A | |||
HV-2153-2 A | |||
HV-2154-1 A | |||
HV-2154-2 A | |||
Flow element, no e=14bration FT-2167 | FE-2167 A | ||
Flow element, no e=14bration FT-2167 A | |||
XEP-2167 | B Tyne 3 safety related XEP-2167 B | ||
2PS-2167 p | |||
Power sucolv, no entibration FC-2168 | Power sucolv, no entibration FC-2168 B | ||
B FE- | FE-2168 A | ||
Flow element, no calibration | Flow element, no calibration 1706 283 TABLE 1 (continued) | ||
Old New Instrument Class Class Remarks FI-2168 A | |||
B Tvoe 3 safety related FV-2168 A | |||
PS-2168 B | |||
Power sucolv, no calibration FSHL-2168 B | |||
Not on schedule. | |||
Calibrated by Llectricians. | |||
FE-2169 A | |||
Flev element, no en14bration FI-2169 A | |||
B Tne 3 safety related FV-2169 A | |||
ES-2169 B | |||
Power sucolv, ro calibrdtion FSHL-2169 B | |||
Not on schedule. | |||
Calibrated by Electricians. | |||
FE-2170 A | |||
Flow element, no en14bration FI-2170 A | |||
B Tvoe 3 safety related PS-2170 B | |||
Power supply, no calibration | |||
~ | |||
FSHL-2170 B | |||
Not on schedule ~. | |||
Calibrated by Electr1~ ians. | |||
c FE-2171 A | |||
Flov element, no calibration FT-2171 A | |||
B Tvoe 3 safety related PS-2171 B | |||
Power sucolv, no en14bration FSHL-2171 B | |||
Not on schedule. | |||
Calibrated by Electricians. | |||
FE-2172 A | |||
Flow element, no calibration Fr-2172 A | |||
B Type 3 safety related PS-2172 B | |||
Power supoly, no calibration FSHL-2172 B | |||
Not on schedule. | |||
Calibrated by Electricians. | |||
FE-2173 A | |||
Flow element, no calibration FI-2173 A | |||
B Tvoe 3 safety related 1706 284 | |||
~ | |||
TABLE 1 (continued) | TABLE 1 (continued) | ||
Old | Old New Instrument Class Class Remarks XPS-2173 B | ||
Power sunoly, no calibration FSHL-2173 B | |||
Power | Not on schedule. | ||
FE- | Calibrated by Electricians. | ||
FE-2174 A | |||
Power sucolv, | Flow element, no calibration FT-2174 A | ||
Not on schedule. Calibrated by Electricians. | B Tvoe 3 safety related Power sucolv, no calibration IPS-2174 B | ||
FSEL-2174 B | |||
Not on schedule. | |||
Calibrated by Electricians. | |||
PDS-2179 B | |||
Not on schedule. | |||
Not on schedule | Calibrated by Electricians. | ||
FE- | IPS-2179 B | ||
Flov element, no calibration FT- | Power sucoly, no calibration PDS-2).81 B | ||
Not on schedule. | |||
Calibrated hv Electricians. | |||
Not on schedule. Calibrated by Electricians. | IPS-2181 1B Power sucolv, no calibration PDS-2182 B | ||
Not on schedule. | |||
Flow element, no calibration | Calibrated by Electricians. | ||
IPS-2182 B | |||
Power sucolv, no calibration FE-2183 A | |||
Flov element, no calibration FT-2183 A | |||
FE- | B Type 3 safety related ISEL-2183 B | ||
Not on schedule. | |||
Calibrated by Electricians. | |||
_FE-2184 A | |||
Flow element, no calibration FT-2184 A | |||
1706 | B Spe 3 safety related ISHL-2184 B | ||
Not on schedule. | |||
Calibrated bv Electricians. | |||
Flou e'lement, no calibration FE-2185 A | |||
. | FT-2185 A | ||
B Tvoe 3 safety related FSHL-2185 lB Not on schedule. | |||
Calibrated by Electricians. | |||
FE-2186 A | |||
Flov element, no calibration FT-2186 A | |||
B Tvoe 3 safety related 1706 285 TABLE 1 (continued) | |||
Old New Instru:sent Class Class Remarks ISHL-2186 B | |||
Not on schedule. | |||
Calibrated by Electricians. | |||
HV-2187-1 A | |||
HV-2187-2 A | |||
HV-2187-3 A | |||
HV-2187-4 A | |||
~ | |||
HV-2187-5 A | |||
HV-2187-6 A | |||
HV-2187-7 A | |||
HV-2187-8 A | |||
HV-2187-9 t | |||
HV-2188-1 A | |||
HV-2188-2 A | |||
HV-2188-3 | |||
~A HV-2188-4 A | |||
HV-2188-5 A | |||
HV-2188-6 A | |||
HV-2188-7 A | |||
HV-2188-8 A | |||
HV-2188-9 A | |||
HV-2189-1 A | |||
HV-2189-2 A | |||
HV-2189-3 A | |||
HV-2189-4 A | |||
1706 286 TABLE 1 (continued) | |||
Old New Instrument Class Class Remarks HV-2189-5 A | |||
HV-2189-6 A | |||
HV-2189-7 A | |||
HV-2189-8 A | |||
HV-2189-9 A | |||
HV-2190-1 A | |||
HV-2190-2 A | |||
HV-2190-3 A | |||
HV-2190-4 A | |||
HV-2190-5 A | |||
HV-2190-6 A | |||
HV-2190-7 A | |||
HV-2190-8 A | |||
HV-2190-9 A | |||
HV-2193 A | |||
HV-2194 A | |||
PM-21105 B | |||
XPS-21118 B | |||
Power sucoly, no calibration LSHL-21124 3 | |||
Not on schedule. | |||
Calibrated by Electricians. | |||
LT-21135 A | |||
B Tvoe 3 safety related LT-21136 A | |||
B Tvoe 3 safety related FSH-21137 B | |||
Alarm switch, no calibration FSH-21138 B | |||
Alarm switch, no calibration 1706 287 | |||
~ | |||
TABLE 1 (continued) | TABLE 1 (continued) | ||
Old | Old New Instrtment Class Class Panarks | ||
_ FSH-21139 B | |||
Alarm switch, no calibration FSH-21140 B | |||
Aha switch, no calibration HV-21142-2 A | |||
HV-21142-4 A | |||
HV-21143 A | |||
Not | PCV-21144 B | ||
Not on schedule SE-21162-1 A | |||
F Soeed probe inacessible SE-21162-2 A | |||
Not on schedule. Calibrated | F Speed probe inacessible PDC-21185 A | ||
B Not safety related PDC-21186 A | |||
B Not safety related PDC-21187 A | |||
B Not safety related PDC-21188 A | |||
B Not safety related PDIS-21190 A | |||
B Not safety related HV-21191-1 A | |||
HV-21191-2 A | |||
HV-21191-3 A | |||
HV-21191-4 A | |||
HV-21192-1 A | |||
HV-21192-2 A | |||
HV-21192-3 A | |||
HV-21192-4 A | |||
1706 288 TABLE 1 (continued) | |||
Old New Ins trumnt Class Class Ems.rks HV-21193-1 A | |||
HV-21193-2 A | |||
HV-21193-3 A | |||
- | HV-21193-4 A | ||
HV-21194-1 A | |||
HV-21194-2 A | |||
HV-21194-3 A | |||
HV-21194-4 A | |||
HV-21203-1 A | |||
HV-21203-2 A | |||
HV-21203-3 A | |||
HV-21203-4 A | |||
HV-21204-1 A | |||
HV-21204-2 A | |||
HV-21204-3 A | |||
HV-21204-4 A | |||
HV-21205-1 A | |||
HV-21205-2 A | |||
HV-21205-3 A | |||
HV-21205-4 A | |||
HV-21206-1 A | |||
HV-21206-2 A | |||
HV-21206-3 A | |||
HV-21206-4 A | |||
1706 289 TABLE 1 (continued) | |||
Old New Instrument Class Class Re= arks FIS-21208 A | |||
B Tvoe 3 safety related FIS-21209 A | |||
B Type 3 safety related HV-21213 A | |||
HV-21214 A | |||
LS-21217 A | |||
B Tvoe 3 safety related LS-21218 A | |||
B Tvoe 3 safety related HV-21225 A | |||
HV-21226 A | |||
FIS-21229 A | |||
B Type 3 safety related HV-21233 A | |||
LSH-21234 A | |||
B Tvpe 3 safety related HV-21235 A | |||
LSH-21235 A | |||
B | |||
' Tvoe 3 safety related HV-21236 A | |||
LSH-21236 A | |||
B Tvoe 3 safety related PI-21241 A | |||
D Local indicators PI-21242 A | |||
D Local indicators PI-21243 A | |||
B Not safety related PT-21443 A | |||
B Tvoe 3 safety related PI-21244 A | |||
B Not safety related PT-21244 A | |||
B Troe 3 safety related HV-21252-1 A | |||
HV-21252-2 A | |||
1706 290 TABLE 1 (continued) | |||
Old New Ins tru: ant Class Class Remarks HV-21252-5 A | |||
HV-21257 A | |||
HV-21258 A | |||
HV-21259 A | |||
A HV-21260 TE-21265-1 thru -15 F | |||
TE-21266-1 thru -15 F | |||
TE-2126 7-1 thru -15 F | |||
TE-21268-1 thru -15 F | |||
TE-21272-1 thru -175 F | |||
HV-212 77-1 A | |||
HV-21277-2 A | |||
HV-21277-3 K | |||
HV-21277-4 A | |||
HV-21277-5 A | |||
HV-21277-6 A | |||
HV-21277-7 A | |||
PI-21283 A | |||
B Not safety related PSL-21283 B | |||
Not on schedule. | |||
Calibrated by. Electricians. | |||
PI-21284 A | |||
B Not safety related PT-21284 A | |||
B Type 3 safety related PSL-21284 3 | |||
Not on schedule. | |||
Calibrated by Electricians. | |||
PI-21285 C | |||
Does not exist 1706 291 TABLE 1 (continued) | |||
Old New Instrumnt Class Class Rc= arks PT-21285-1 A | |||
B Tvoe 3 safety related PSL-21285 C | |||
Added this instrument PSL-21285-1 A | |||
B Type 3 safety related PT-21286-1 A | |||
B Type 3 safety related PDI-212 86-3 C | |||
~ | |||
PSL-21286 C | |||
LS-21287 A | |||
B Tvoe 3 safety related LS-21288 A | |||
B Type 3 safety related Differential pressure transmitters, Type PDT-21291 A | |||
D 3 safety related Dif ferential pressure transmitters, Type PM-21292 A | |||
D 3 safety reloted Differential pressure transmitters, Type PDT-21293 A | |||
D 3 safety related Differential pressure transmitters, Type PM-21294 A | |||
D 3 safety related Differential pressure transmitters, Type PM-21295 A | |||
D 3 safety related Differential pressure transmitters, Type PM-21296 A | |||
D 3 safety related PS-21313 A | |||
B Tyne 3 safety related PS-21314 A | |||
B Tyne 3 safety related | |||
,PS-21315 A | |||
B Tvoe 3 safety related PS-21316 A | |||
B Tvoe 3 safety related HV-21335 A | |||
HV-21336 A | |||
HV-21337 A | |||
HV-21338 A | |||
PDT-21339 A | |||
B Tvoe 3 sa fety related 1706 292 TAB 1E 1 (continued) | |||
Old New Instrumnt Class Class Remarks | |||
__PDT-21340 A | |||
B Tvoe 3 safety related PDT-21341 A | |||
B Tyne 3 safety related PDT-21342 A | |||
B Tvoe 3 safety related HV-21345 A | |||
i HV-21346 L-A HV-21347 A | |||
HV-21348 A | |||
HV-21349 A | |||
HV-21350 A | |||
HV-21351 A | |||
HV-21352 A | |||
HV-21353 A | |||
'HV-21354 A' | |||
HV-21355 A | |||
PS-21356 A | |||
B Tyne 3' safety related PS-21357 A | |||
B Type 3 safety related PS-21358 A | |||
B Tvoe 3 safety related PS-21359 A | |||
B Tvoe 3 safety related PS-21360 A | |||
B Type 3 safety related HV-21362 A | |||
PS-21363 A | |||
Tvoe 3 safety related HV-21364 A | |||
PS-21365 A | |||
Tvoe 3 safety related 1706 293 TABLE 1 (continued) | |||
Old New Instrument Class Class Remarks TI-21373 D | |||
TI-21374 D | |||
PI-21375 D | |||
PI-21376 D | |||
FIS-21377 A | |||
B Tvoe 3 safety related FIS-21378 A | |||
B Tvoe 3 safety related FIS-21379 A | |||
B Tvoe 3 safety related FIS-21380 A | |||
B Tvoe 3 safety related TI-21387 D | |||
PDT-21389 A | |||
B Troe 3 safety related PDT-21390 A | |||
B Tyne 3 safety related PUr-21391 A | |||
B Tvoe 3 safety related PDT-21392 A | |||
B~ | |||
Tvoe 3 safety related PDIS-21393 C | |||
PDIS-21399 A | |||
D Differential oressure indicator on strainer Differential pressure on =1scellaneous PDIS-21400 A | |||
D ecuiement Differential pressure on t 'scellaneous PDIS-21401 A | |||
D ecutoment Differential pressure on miscellaneous PDIS-21402 A | |||
D eautoment Differential pressure on miscellaneous PDIS-21403 A | |||
D ecuipment | |||
~ | |||
PDI-21411 C | |||
Control room indicator IPS-21411 C | |||
Power sucolv PDI-21412 C | |||
Control room indicator IPS-21412 C | |||
Power suoul-1706 294 | |||
~ | |||
TABLE 1 (continued) | TABLE 1 (continued) | ||
Old | Old New Instrument Class Class Rer: arks PDI-21413 C | ||
Control room indicator IPS-21413 C | |||
Power sucolv PDI-21414 C | |||
Control room indicator IPS-21414 C | |||
Power sunolv HV-21415-1 A | |||
EV-21415-2 A | |||
HV-21416-1 A | |||
HV-21416-2 A | |||
P DT-21417 A | |||
B Tvoe 3 safety related PDT-21418 A | |||
B Tvoe 3 safety related PDT-21419 A | |||
B Tvoe 3 safety related PDT-21420 A | |||
B Tvoe 3 safety related LIS-21474 A | |||
B Tvoe 3 safety related LIS-21475 A | |||
B Tyne 3 safety related LIS-21476 A | |||
B Tvpe 3 safety related LIS-21477 A | |||
B Tvoe 3 safety related PM-21484 B | |||
PI-21487-1 A | |||
B Tvoe 3 safety related PI-23 487-2 A | |||
B Tvoe 3 safety related PI-21487-3 A | |||
B Tvoe 3 safety related 1 | |||
PI-21487-4 A | |||
lB Tvoe 3 safety related i | |||
PI-21487-5 A | |||
I B Tvoe 3 safety related PI-21487-6 A | |||
B Tvoe 3 safety related 1706 295 | |||
Control room indicator IPS-21413 | |||
Power sucolv PDI-21414 | |||
Control room indicator IPS-21414 | |||
Power sunolv HV-21415-1 | |||
A | |||
EV-21415-2 | |||
PI-21487-3 | |||
PI-21487-4 | |||
PI-21487-5 | |||
1706 295 | |||
~ | ~ | ||
TABLE 1 (continued) | TABLE 1 (continued) | ||
Old | Old New Instrument Class Class Rararks PI-21487-7 A | ||
Sight glass, no calibration | B Troe 3 safety related PI-21487-8 A | ||
B Tyne 3 safety related LG-21498-1 A | |||
LS-21498-1 | Sight glass, no calibration LG-21498-2 A | ||
Sight class, no calibration LS-21499-1 | Sight glass, no calibration LS-21498-1 A | ||
Sight class, no calibration LG-21500-2 | B Tyne 3 safety related LS-2149 8-2 A | ||
B Tyne 3 safe.tv related LG-21499-1 A | |||
Sicht class, no calibration LG-21499-2 A | |||
Sight class, no calibration LS-21499-1 A | |||
B Tvoe 3 safety related LS-21499-2 A | |||
B Tyne 3 safety related LG-21500-1 A | |||
Sight class, no calibration LG-21500-2 A | |||
Sicht class, no calibration | Sicht class, no calibration | ||
'IS-21500-1 A | |||
Sicht class, no r nlibration LG-21501-2 | B-Troe 3 safety related LS-21500-2 A | ||
Sicht glass, no calibration LS-21501-1 | B Tvoe 3 safety related LG-21501-1 A | ||
PI-21507 | Sicht class, no r nlibration LG-21501-2 A | ||
Sicht glass, no calibration LS-21501-1 A | |||
B Tvoe 3 safety related LS-21501-2 A | |||
B Tvoe 3 safety related PS-21503 A | |||
B Tvoe 3 safety related PI-21507 B | |||
D Local indicator PI-21508 B | |||
D Local indicator 1706 296 | |||
TMU 2 FUNCTIONAL TEST CATEGORY CHMGE Old New Instrument Categorv Catecorv Remarks Instruments like this on other circu-lator are required to be functionally XSL-2110 1 | |||
3 tested. | |||
Other instruments in this control loop LAL-2137 3 | |||
are alreadv functionally tested. | |||
Other instruments in this control | Other instruments in this control loop LAL-2138 3 | ||
are alreadv functionally tested. | |||
Other instruments in this control | Other instruments in this control loop LAH-2145 3 | ||
are already functionally tested. | |||
Other instruments in this control | Other instruments in this control loop LAH-2146 3 | ||
are alreadv functionally tested. | |||
Other instruments in this control | Other instruments in this control loop PDS-2152 3 | ||
are alreadv functionally tested. | |||
Other instruments in this control | i Other instruments in this control loop PDAH-2152 l3 are already functionally tested. | ||
Other instruments in this control loop FSHL-2167 3 | |||
i Other instruments in this control | are already functionally tested. | ||
l3 | This device was not shown on the in-PDAE-2180 3 | ||
Other instruments in this control | strument list. | ||
Valve function not important to system PV-21120-1 3 | |||
This device was not shown on the in-PDAE-2180 | 2 ope ration. | ||
Other instruments in this control loop LAHL-21121 1-3 are already functionally tested. | |||
Valve function not important to system PV-21120-1 | Other instruments in this control loop LSE-21121 3 | ||
Other instruments in this control loop LAHL-21121 1- | are alreadv functionally tested. | ||
Other instruments in this control loop LSE-21121 | Other instruments in this control loop LAHL-21122 3 | ||
are alreadv functionally tested. | |||
Other instruments in this control loop LAHL-21122 | Other instruments in this control loop LSE-21122 3 | ||
are alreadv functionally tested. | |||
Other instruments in this control loop LSE-21122 | Other instruments in this control loop LAE-21123 3 | ||
are already functionally tested. | |||
Other instruments in this control loop LAE-21123 | Other instruments in this control loop LSHL-21123 3 | ||
are already functionally tested. | |||
Other instruments in this control loop LSHL-21123 | Other instruments in this control loop LEL-21124 3 | ||
are already functionally tested. | |||
Other instruments in this control loop LSE-21124 3 | |||
Other instruments in this control loop LEL-21124 | are already functionally tested. | ||
Valve function is adequately tested by PCV-21131 3 | |||
Other instruments in this control loop LSE-21124 | 1 normal operation. | ||
Other instruments in this control loop LAE-21135 3 | |||
Valve function is adequately tested by PCV-21131 | are already functionally tested. | ||
Other instruments in this control loop LAE-21135 | 1706 297 TABLE 2 (continued) | ||
Old New Ins tru:nent Category Categorv pama rks Other instru:nents in this control loop LAHL-21136 3 | |||
are alreadv functionally tested. | |||
HC-21185 3 | |||
1706 297 | |||
TABLE 2 (continued) | |||
Old | |||
HC-21185 | |||
Instru:nent does not aHst. | Instru:nent does not aHst. | ||
Instrument is not calibrated, but 2PS-21185 | Instrument is not calibrated, but 2PS-21185 3 | ||
needs functional testing. | |||
Instrument is noe calibrated, but IPS-21186 | Instrument is noe calibrated, but IPS-21186 3 | ||
needs functional testing. | |||
Instruznent is not calibrated, but IPS-21187 | Instruznent is not calibrated, but IPS-21187 3 | ||
needs functional testing. | |||
Instrument is not calibrated, but IPS-21188 3 | |||
Instrument is not calibrated, but IPS-21188 | needs functional testing. | ||
Other instruments in this control loop HV-21233 3 | |||
Other instruments in this control loop HV-21233 | are already functionally tested. | ||
Other instruments in this control loop HV-21234 3 | |||
Other instruments in this control loop HV-21234 | are alreadv functionally tes ted. | ||
Other instruments in this control loop HV-21235 3 | |||
Other instruments in this control loop HV-21235 | are alreadv functionally tested. | ||
Other instruments in this control loop HV-21236 3 | |||
Other instruments in this control loop HV-21236 | are already functionally tested. | ||
Other instruments in this control loop PAL-21283 3 | |||
Other instruments in this control loop PAL-21283 | are already functionally tested. | ||
Other instruments in this control loop PAL-21284 3 | |||
Other instruments in this control loop PAL-21284 | are already functionally tested. | ||
Other instruments in this control loop PAL-21285 3 | |||
Other instruments in this control loop PAL-21285 | are already functionally tested. | ||
Other instruments in this control loop PAL-21286 3 | |||
Other instruments in this control loop PAL-21286 | are already functionally tested. | ||
Other instruments in this control loop LAL-21287 3 | |||
Other instruments in this control loop LAL-21287 | are already functionally tested. | ||
Other instruments in this control loop LAL-21288 3 | |||
Other instruments in this control loop LAL-21288 | are already functionally tested. | ||
Instrument is Type 3, therefore needs 7S-21333 3 | |||
Instrument is Type 3, therefore needs 7S-21333 | |||
no functional test. | no functional test. | ||
Otherrinstruments in this control looE LAHL-21494 | Otherrinstruments in this control looE LAHL-21494 3 | ||
are alreadv functionally tested. | |||
Other instruments in this control loop LAHL-21498 | Other instruments in this control loop LAHL-21498 3 | ||
are already functionally tested. | |||
Other instruments in tnis control loop | Other instruments in tnis control loop 3 | ||
are already functionally tested. | |||
Other instruments in this control loop PDSHL-21518 | PDAHL-21518 Other instruments in this control loop PDSHL-21518 3 | ||
! are already fun ctionally tested. | |||
Other instruments in this control loop PDAHL-21526 | Other instruments in this control loop PDAHL-21526 3 | ||
are already functionally tested. | |||
Other instruments in this control loop PDSHL-21526 | Other instruments in this control loop PDSHL-21526 3 | ||
are already functionally tested. | |||
Other instruments in this control loop | Other instruments in this control loop 3 | ||
are already functionally tested. | |||
1706 298 | PDAHL-21529 1706 298 | ||
.~ | |||
TABLE 2 (continued) | TABLE 2 (continued) | ||
Old | Old New Ins trument Categorv Categorv Re-a-ks Other instruments in this control loop PDSHL-21529 3 | ||
are already functionally tested. | |||
Other instrumen ts in tais control loop PDAHL-21530 | Other instrumen ts in tais control loop PDAHL-21530 3 | ||
are already functionally tested. | |||
Other instruments in this control loop PDSHL-21530 | Other instruments in this control loop PDSHL-21530 3 | ||
are already functionally tes ted. | |||
s | s | ||
~ | |||
1706 299 o | |||
1706 299 | ~ | ||
TABLE 3 INSTRUMENTS HEQUIRING A FINCTIONAL TEST BUT CANNOT BE TESTED BECAUSE PLANT CONDITIONS PROHIBIT THE IMPLEMENTATION OF THE FINCTIONAL TEST HC-21417 HC-21418 PDC-21417-1 PDC-21418-1 PDC-21417-2 PDC-21418-2 PDI-21417 PDI-21418 PDM-21417-1 PDM-21418-1 PDM-21417-2 PDM-21418-2 PDM-21417-3 PDM-21418-3 PDM-21417-4 PDM-21418-4 PDI-21417 PDT-21418 IEP-21417 IEP-21418 IPS-21417 IPS-21418 1706 300 | |||
o | |||
PDM-21417-2 | |||
PDM-21417-3 | |||
1706 300 | |||
_}} | _}} | ||
Latest revision as of 21:08, 3 January 2025
| ML19257A851 | |
| Person / Time | |
|---|---|
| Site: | Fort Saint Vrain |
| Issue date: | 11/30/1979 |
| From: | Warembourg D PUBLIC SERVICE CO. OF COLORADO |
| To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| Shared Package | |
| ML19257A845 | List: |
| References | |
| P-79285, NUDOCS 8001090226 | |
| Download: ML19257A851 (21) | |
Text
.
r-puhuc service company ce omende
~.
16805 Weld County Road 191/2, Platteville, Colorado 80651
_c
.i November 30, 1979 Fort St. Vrain Unit No. 1 P-79285 Mr. Karl V. Seyfrit, Director Nuclear Regulatory Commission Region IV Office of Inspection and Enforcement 611 Ryan Plaza Driva Suite 1000 Arlington, Texas 76012 Docket No. 50-267
SUBJECT:
System 21 Instrument Calibration
REFERENCE:
- 1) P-78107 2)
P-79225
Dear Mr. Seyfrit:
The above referenced letters transmitted to your office information pertaining to System 21 control and instrumentation classes and func-tional test categories. Continued review of the information avail-able indicates that some discrepancies existed in the tables included in the referenced letters.
The new tables attached reflect changes and additions necessary to update the information for your records.
For purposes of clarifica-tion to the tables, Safety-Related Type 3 applies to instruments which must only maintain their pressure boundary following a seismic event. See Attachment 1 for further clarification.
If you have any questions, please contact me at (303) 571-7436.
Very truly yours,
& 7Yuudn Don Warembourg v
Manager, Nuclear Production 1706 280 DW/alk 8 0 01090 Et6
ATTACHMENT 1 The following instrument classes are used:
Class A - Instruments defined by document 90-SR-6-2, May 12, 1978, as being
" safety related." This safety related classification will extend
"... to components which must function during or following a seismic event," and "... components which must function only following a seismic event."
All these instruments are presently being cali-brated annually under ADM-14 (annual calibration program).
Class B - Instruments presently calibrated annually by plant personnel.
These instruments, along with Class A, are listed on the master calibration schedule.
Class C - Instruments calibrated by surveillance tests as outlined in the Technical Specifications.
Class D - Instruments that are not presently calibrated on an annual basis and are used for local indication and/or system performance diag-nosis only.
Class F - Instruments that can't be calibrated because of inaccessibility.
The following type definitions are used for equipment and instruments other than valves:
Type 1 - Applies to components which must function both during and fol-loving a seismic event.
Type 2 - Applies to components which must function only following a seismic event.
Type 3 - Applies to instruments which must only maintain their pressure boundary following a seismic event.
1706 281 TABLE 1 INSTRUMENT CLASS CHANGES Old New Instrument Class Class Remarks SV-2105 B
A ZI-2105 B
D Oscilloscope used for diagnosis only.
ZI-2106 B
D Oscilloscope used for diagnosis only.
HV-2109-1 A
HV-2109-2 A
HV-2110-1 A
HV-2110-2 A
ZI-2111 Change to ZI-2111-1 ZI-2111-1 B
ZI-2112-1 B
HV-2115-1 A
HV-2115-2 A
SV-2115 -
B A
HV-2116-1 A
HV-2116-2 A
Type 3 safety related, on calibration XEP-2135 A
B schedule.
Type 3 safety related, on calibration XEP-2136 A
B schedule.
FE-2141 A
Flow element, no calibration FI-2141 A
B Type 3 safety related FE-2142 A
Flow element, no calibration FT-2142 A
B Type 3 safety related XPS-2142 B
Power suop1v, no calibration PM-2143-1 3
Loop 1 oneumatic booster, no calibration PM-2143-2 B
Looo 1 pneumatic booster, no calibration 1706 282 TABLE 1 (continued)
Old New Instru:xnt Class Class Remarks u
PDIC-2143 lA B
Tvoe 3 safety related PM-2144-1 B
Loop 2 oneumatic boos ter, no ca14bration PM-2144-2 B
Looo 2 pneu=atic booster, no calibration PDIC-2144 A
B Type 3 safety related LS-2145 A
B Type 3 safety related LS-2146 A
B Tvoe 3 safety related PDT-?l47 A
B Tvoe 3 safety related PDT-2148 A
B Tvoe 3 safety related FE-2151 A
Flow element, no caldbration i
FIC-2151 A
B f Type 3 safety related FIS-2151 A
B Tvoe 3 safety related HV-2152 A
PDS-2152 A
B Tvoe 3 safety related HV-2153-1 A
HV-2153-2 A
HV-2154-1 A
HV-2154-2 A
FE-2167 A
Flow element, no e=14bration FT-2167 A
B Tyne 3 safety related XEP-2167 B
2PS-2167 p
Power sucolv, no entibration FC-2168 B
FE-2168 A
Flow element, no calibration 1706 283 TABLE 1 (continued)
Old New Instrument Class Class Remarks FI-2168 A
B Tvoe 3 safety related FV-2168 A
PS-2168 B
Power sucolv, no calibration FSHL-2168 B
Not on schedule.
Calibrated by Llectricians.
FE-2169 A
Flev element, no en14bration FI-2169 A
B Tne 3 safety related FV-2169 A
ES-2169 B
Power sucolv, ro calibrdtion FSHL-2169 B
Not on schedule.
Calibrated by Electricians.
FE-2170 A
Flow element, no en14bration FI-2170 A
B Tvoe 3 safety related PS-2170 B
Power supply, no calibration
~
FSHL-2170 B
Not on schedule ~.
Calibrated by Electr1~ ians.
c FE-2171 A
Flov element, no calibration FT-2171 A
B Tvoe 3 safety related PS-2171 B
Power sucolv, no en14bration FSHL-2171 B
Not on schedule.
Calibrated by Electricians.
FE-2172 A
Flow element, no calibration Fr-2172 A
B Type 3 safety related PS-2172 B
Power supoly, no calibration FSHL-2172 B
Not on schedule.
Calibrated by Electricians.
FE-2173 A
Flow element, no calibration FI-2173 A
B Tvoe 3 safety related 1706 284
~
TABLE 1 (continued)
Old New Instrument Class Class Remarks XPS-2173 B
Power sunoly, no calibration FSHL-2173 B
Not on schedule.
Calibrated by Electricians.
FE-2174 A
Flow element, no calibration FT-2174 A
B Tvoe 3 safety related Power sucolv, no calibration IPS-2174 B
FSEL-2174 B
Not on schedule.
Calibrated by Electricians.
PDS-2179 B
Not on schedule.
Calibrated by Electricians.
IPS-2179 B
Power sucoly, no calibration PDS-2).81 B
Not on schedule.
Calibrated hv Electricians.
IPS-2181 1B Power sucolv, no calibration PDS-2182 B
Not on schedule.
Calibrated by Electricians.
IPS-2182 B
Power sucolv, no calibration FE-2183 A
Flov element, no calibration FT-2183 A
B Type 3 safety related ISEL-2183 B
Not on schedule.
Calibrated by Electricians.
_FE-2184 A
Flow element, no calibration FT-2184 A
B Spe 3 safety related ISHL-2184 B
Not on schedule.
Calibrated bv Electricians.
Flou e'lement, no calibration FE-2185 A
FT-2185 A
B Tvoe 3 safety related FSHL-2185 lB Not on schedule.
Calibrated by Electricians.
FE-2186 A
Flov element, no calibration FT-2186 A
B Tvoe 3 safety related 1706 285 TABLE 1 (continued)
Old New Instru:sent Class Class Remarks ISHL-2186 B
Not on schedule.
Calibrated by Electricians.
HV-2187-1 A
HV-2187-2 A
HV-2187-3 A
HV-2187-4 A
~
HV-2187-5 A
HV-2187-6 A
HV-2187-7 A
HV-2187-8 A
HV-2187-9 t
HV-2188-1 A
HV-2188-2 A
HV-2188-3
~A HV-2188-4 A
HV-2188-5 A
HV-2188-6 A
HV-2188-7 A
HV-2188-8 A
HV-2188-9 A
HV-2189-1 A
HV-2189-2 A
HV-2189-3 A
HV-2189-4 A
1706 286 TABLE 1 (continued)
Old New Instrument Class Class Remarks HV-2189-5 A
HV-2189-6 A
HV-2189-7 A
HV-2189-8 A
HV-2189-9 A
HV-2190-1 A
HV-2190-2 A
HV-2190-3 A
HV-2190-4 A
HV-2190-5 A
HV-2190-6 A
HV-2190-7 A
HV-2190-8 A
HV-2190-9 A
HV-2193 A
HV-2194 A
PM-21105 B
XPS-21118 B
Power sucoly, no calibration LSHL-21124 3
Not on schedule.
Calibrated by Electricians.
LT-21135 A
B Tvoe 3 safety related LT-21136 A
B Tvoe 3 safety related FSH-21137 B
Alarm switch, no calibration FSH-21138 B
Alarm switch, no calibration 1706 287
~
TABLE 1 (continued)
Old New Instrtment Class Class Panarks
_ FSH-21139 B
Alarm switch, no calibration FSH-21140 B
Aha switch, no calibration HV-21142-2 A
HV-21142-4 A
HV-21143 A
PCV-21144 B
Not on schedule SE-21162-1 A
F Soeed probe inacessible SE-21162-2 A
F Speed probe inacessible PDC-21185 A
B Not safety related PDC-21186 A
B Not safety related PDC-21187 A
B Not safety related PDC-21188 A
B Not safety related PDIS-21190 A
B Not safety related HV-21191-1 A
HV-21191-2 A
HV-21191-3 A
HV-21191-4 A
HV-21192-1 A
HV-21192-2 A
HV-21192-3 A
HV-21192-4 A
1706 288 TABLE 1 (continued)
Old New Ins trumnt Class Class Ems.rks HV-21193-1 A
HV-21193-2 A
HV-21193-3 A
HV-21193-4 A
HV-21194-1 A
HV-21194-2 A
HV-21194-3 A
HV-21194-4 A
HV-21203-1 A
HV-21203-2 A
HV-21203-3 A
HV-21203-4 A
HV-21204-1 A
HV-21204-2 A
HV-21204-3 A
HV-21204-4 A
HV-21205-1 A
HV-21205-2 A
HV-21205-3 A
HV-21205-4 A
HV-21206-1 A
HV-21206-2 A
HV-21206-3 A
HV-21206-4 A
1706 289 TABLE 1 (continued)
Old New Instrument Class Class Re= arks FIS-21208 A
B Tvoe 3 safety related FIS-21209 A
B Type 3 safety related HV-21213 A
HV-21214 A
LS-21217 A
B Tvoe 3 safety related LS-21218 A
B Tvoe 3 safety related HV-21225 A
HV-21226 A
FIS-21229 A
B Type 3 safety related HV-21233 A
LSH-21234 A
B Tvpe 3 safety related HV-21235 A
LSH-21235 A
B
' Tvoe 3 safety related HV-21236 A
LSH-21236 A
B Tvoe 3 safety related PI-21241 A
D Local indicators PI-21242 A
D Local indicators PI-21243 A
B Not safety related PT-21443 A
B Tvoe 3 safety related PI-21244 A
B Not safety related PT-21244 A
B Troe 3 safety related HV-21252-1 A
HV-21252-2 A
1706 290 TABLE 1 (continued)
Old New Ins tru: ant Class Class Remarks HV-21252-5 A
HV-21257 A
HV-21258 A
HV-21259 A
A HV-21260 TE-21265-1 thru -15 F
TE-21266-1 thru -15 F
TE-2126 7-1 thru -15 F
TE-21268-1 thru -15 F
TE-21272-1 thru -175 F
HV-212 77-1 A
HV-21277-2 A
HV-21277-3 K
HV-21277-4 A
HV-21277-5 A
HV-21277-6 A
HV-21277-7 A
PI-21283 A
B Not safety related PSL-21283 B
Not on schedule.
Calibrated by. Electricians.
PI-21284 A
B Not safety related PT-21284 A
B Type 3 safety related PSL-21284 3
Not on schedule.
Calibrated by Electricians.
PI-21285 C
Does not exist 1706 291 TABLE 1 (continued)
Old New Instrumnt Class Class Rc= arks PT-21285-1 A
B Tvoe 3 safety related PSL-21285 C
Added this instrument PSL-21285-1 A
B Type 3 safety related PT-21286-1 A
B Type 3 safety related PDI-212 86-3 C
~
PSL-21286 C
LS-21287 A
B Tvoe 3 safety related LS-21288 A
B Type 3 safety related Differential pressure transmitters, Type PDT-21291 A
D 3 safety related Dif ferential pressure transmitters, Type PM-21292 A
D 3 safety reloted Differential pressure transmitters, Type PDT-21293 A
D 3 safety related Differential pressure transmitters, Type PM-21294 A
D 3 safety related Differential pressure transmitters, Type PM-21295 A
D 3 safety related Differential pressure transmitters, Type PM-21296 A
D 3 safety related PS-21313 A
B Tyne 3 safety related PS-21314 A
B Tyne 3 safety related
,PS-21315 A
B Tvoe 3 safety related PS-21316 A
B Tvoe 3 safety related HV-21335 A
HV-21336 A
HV-21337 A
HV-21338 A
PDT-21339 A
B Tvoe 3 sa fety related 1706 292 TAB 1E 1 (continued)
Old New Instrumnt Class Class Remarks
__PDT-21340 A
B Tvoe 3 safety related PDT-21341 A
B Tyne 3 safety related PDT-21342 A
B Tvoe 3 safety related HV-21345 A
i HV-21346 L-A HV-21347 A
HV-21348 A
HV-21349 A
HV-21350 A
HV-21351 A
HV-21352 A
HV-21353 A
'HV-21354 A'
HV-21355 A
PS-21356 A
B Tyne 3' safety related PS-21357 A
B Type 3 safety related PS-21358 A
B Tvoe 3 safety related PS-21359 A
B Tvoe 3 safety related PS-21360 A
B Type 3 safety related HV-21362 A
PS-21363 A
Tvoe 3 safety related HV-21364 A
PS-21365 A
Tvoe 3 safety related 1706 293 TABLE 1 (continued)
Old New Instrument Class Class Remarks TI-21373 D
TI-21374 D
PI-21375 D
PI-21376 D
FIS-21377 A
B Tvoe 3 safety related FIS-21378 A
B Tvoe 3 safety related FIS-21379 A
B Tvoe 3 safety related FIS-21380 A
B Tvoe 3 safety related TI-21387 D
PDT-21389 A
B Troe 3 safety related PDT-21390 A
B Tyne 3 safety related PUr-21391 A
B Tvoe 3 safety related PDT-21392 A
B~
Tvoe 3 safety related PDIS-21393 C
PDIS-21399 A
D Differential oressure indicator on strainer Differential pressure on =1scellaneous PDIS-21400 A
D ecuiement Differential pressure on t 'scellaneous PDIS-21401 A
D ecutoment Differential pressure on miscellaneous PDIS-21402 A
D eautoment Differential pressure on miscellaneous PDIS-21403 A
D ecuipment
~
PDI-21411 C
Control room indicator IPS-21411 C
Power sucolv PDI-21412 C
Control room indicator IPS-21412 C
Power suoul-1706 294
~
TABLE 1 (continued)
Old New Instrument Class Class Rer: arks PDI-21413 C
Control room indicator IPS-21413 C
Power sucolv PDI-21414 C
Control room indicator IPS-21414 C
Power sunolv HV-21415-1 A
EV-21415-2 A
HV-21416-1 A
HV-21416-2 A
P DT-21417 A
B Tvoe 3 safety related PDT-21418 A
B Tvoe 3 safety related PDT-21419 A
B Tvoe 3 safety related PDT-21420 A
B Tvoe 3 safety related LIS-21474 A
B Tvoe 3 safety related LIS-21475 A
B Tyne 3 safety related LIS-21476 A
B Tvpe 3 safety related LIS-21477 A
B Tvoe 3 safety related PM-21484 B
PI-21487-1 A
B Tvoe 3 safety related PI-23 487-2 A
B Tvoe 3 safety related PI-21487-3 A
B Tvoe 3 safety related 1
PI-21487-4 A
lB Tvoe 3 safety related i
PI-21487-5 A
I B Tvoe 3 safety related PI-21487-6 A
B Tvoe 3 safety related 1706 295
~
TABLE 1 (continued)
Old New Instrument Class Class Rararks PI-21487-7 A
B Troe 3 safety related PI-21487-8 A
B Tyne 3 safety related LG-21498-1 A
Sight glass, no calibration LG-21498-2 A
Sight glass, no calibration LS-21498-1 A
B Tyne 3 safety related LS-2149 8-2 A
B Tyne 3 safe.tv related LG-21499-1 A
Sicht class, no calibration LG-21499-2 A
Sight class, no calibration LS-21499-1 A
B Tvoe 3 safety related LS-21499-2 A
B Tyne 3 safety related LG-21500-1 A
Sight class, no calibration LG-21500-2 A
Sicht class, no calibration
'IS-21500-1 A
B-Troe 3 safety related LS-21500-2 A
B Tvoe 3 safety related LG-21501-1 A
Sicht class, no r nlibration LG-21501-2 A
Sicht glass, no calibration LS-21501-1 A
B Tvoe 3 safety related LS-21501-2 A
B Tvoe 3 safety related PS-21503 A
B Tvoe 3 safety related PI-21507 B
D Local indicator PI-21508 B
D Local indicator 1706 296
TMU 2 FUNCTIONAL TEST CATEGORY CHMGE Old New Instrument Categorv Catecorv Remarks Instruments like this on other circu-lator are required to be functionally XSL-2110 1
3 tested.
Other instruments in this control loop LAL-2137 3
are alreadv functionally tested.
Other instruments in this control loop LAL-2138 3
are alreadv functionally tested.
Other instruments in this control loop LAH-2145 3
are already functionally tested.
Other instruments in this control loop LAH-2146 3
are alreadv functionally tested.
Other instruments in this control loop PDS-2152 3
are alreadv functionally tested.
i Other instruments in this control loop PDAH-2152 l3 are already functionally tested.
Other instruments in this control loop FSHL-2167 3
are already functionally tested.
This device was not shown on the in-PDAE-2180 3
strument list.
Valve function not important to system PV-21120-1 3
2 ope ration.
Other instruments in this control loop LAHL-21121 1-3 are already functionally tested.
Other instruments in this control loop LSE-21121 3
are alreadv functionally tested.
Other instruments in this control loop LAHL-21122 3
are alreadv functionally tested.
Other instruments in this control loop LSE-21122 3
are alreadv functionally tested.
Other instruments in this control loop LAE-21123 3
are already functionally tested.
Other instruments in this control loop LSHL-21123 3
are already functionally tested.
Other instruments in this control loop LEL-21124 3
are already functionally tested.
Other instruments in this control loop LSE-21124 3
are already functionally tested.
Valve function is adequately tested by PCV-21131 3
1 normal operation.
Other instruments in this control loop LAE-21135 3
are already functionally tested.
1706 297 TABLE 2 (continued)
Old New Ins tru:nent Category Categorv pama rks Other instru:nents in this control loop LAHL-21136 3
are alreadv functionally tested.
HC-21185 3
Instru:nent does not aHst.
Instrument is not calibrated, but 2PS-21185 3
needs functional testing.
Instrument is noe calibrated, but IPS-21186 3
needs functional testing.
Instruznent is not calibrated, but IPS-21187 3
needs functional testing.
Instrument is not calibrated, but IPS-21188 3
needs functional testing.
Other instruments in this control loop HV-21233 3
are already functionally tested.
Other instruments in this control loop HV-21234 3
are alreadv functionally tes ted.
Other instruments in this control loop HV-21235 3
are alreadv functionally tested.
Other instruments in this control loop HV-21236 3
are already functionally tested.
Other instruments in this control loop PAL-21283 3
are already functionally tested.
Other instruments in this control loop PAL-21284 3
are already functionally tested.
Other instruments in this control loop PAL-21285 3
are already functionally tested.
Other instruments in this control loop PAL-21286 3
are already functionally tested.
Other instruments in this control loop LAL-21287 3
are already functionally tested.
Other instruments in this control loop LAL-21288 3
are already functionally tested.
Instrument is Type 3, therefore needs 7S-21333 3
no functional test.
Otherrinstruments in this control looE LAHL-21494 3
are alreadv functionally tested.
Other instruments in this control loop LAHL-21498 3
are already functionally tested.
Other instruments in tnis control loop 3
are already functionally tested.
PDAHL-21518 Other instruments in this control loop PDSHL-21518 3
! are already fun ctionally tested.
Other instruments in this control loop PDAHL-21526 3
are already functionally tested.
Other instruments in this control loop PDSHL-21526 3
are already functionally tested.
Other instruments in this control loop 3
are already functionally tested.
PDAHL-21529 1706 298
.~
TABLE 2 (continued)
Old New Ins trument Categorv Categorv Re-a-ks Other instruments in this control loop PDSHL-21529 3
are already functionally tested.
Other instrumen ts in tais control loop PDAHL-21530 3
are already functionally tested.
Other instruments in this control loop PDSHL-21530 3
are already functionally tes ted.
s
~
1706 299 o
~
TABLE 3 INSTRUMENTS HEQUIRING A FINCTIONAL TEST BUT CANNOT BE TESTED BECAUSE PLANT CONDITIONS PROHIBIT THE IMPLEMENTATION OF THE FINCTIONAL TEST HC-21417 HC-21418 PDC-21417-1 PDC-21418-1 PDC-21417-2 PDC-21418-2 PDI-21417 PDI-21418 PDM-21417-1 PDM-21418-1 PDM-21417-2 PDM-21418-2 PDM-21417-3 PDM-21418-3 PDM-21417-4 PDM-21418-4 PDI-21417 PDT-21418 IEP-21417 IEP-21418 IPS-21417 IPS-21418 1706 300