ENS 42140: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) Created page by program invented by Mark Hawes |
StriderTol (talk | contribs) Created page by program invented by StriderTol |
||
| Line 16: | Line 16: | ||
| event date = 11/14/2005 11:41 EST | | event date = 11/14/2005 11:41 EST | ||
| last update date = 11/14/2005 | | last update date = 11/14/2005 | ||
| title = Cladding Failure | | title = Cladding Failure to One Spent Fuel Rod Found During Inspection of Spent Fuel in the Spent Fuel Pool | ||
| event text = On November 14, 2005, WBN was operating at 100% power and an inspection of spent fuel stored in the spent fuel pool (SFP) was being performed. The inspection confirmed that an opening existed in one rod (P9) located in G45 fuel assembly. This assembly is a 17 x 17 Vantage +/Performance + (V+/P+) fuel assembly and it has been used in the core during two previous cycles. The inspection noted some rod cladding failure different than what could be expected. | | event text = On November 14, 2005, WBN was operating at 100% power and an inspection of spent fuel stored in the spent fuel pool (SFP) was being performed. The inspection confirmed that an opening existed in one rod (P9) located in G45 fuel assembly. This assembly is a 17 x 17 Vantage +/Performance + (V+/P+) fuel assembly and it has been used in the core during two previous cycles. The inspection noted some rod cladding failure different than what could be expected. | ||
TVA is making a non-emergency notification in accordance with 10 CFR 50.72(b)(3)(ii)(A). For this event, the cladding failure could be considered to exceed expected values. | TVA is making a non-emergency notification in accordance with 10 CFR 50.72(b)(3)(ii)(A). For this event, the cladding failure could be considered to exceed expected values. | ||
Latest revision as of 21:19, 1 March 2018
| Where | |
|---|---|
| Watts Bar Tennessee (NRC Region 2) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
| LER: | 05000390/LER-2005-002 G45 Fuel Assembly Clad Damage (Preliminary Report) |
| Time - Person (Reporting Time:+2.47 h0.103 days <br />0.0147 weeks <br />0.00338 months <br />) | |
| Opened: | Rick O'Rear 19:09 Nov 14, 2005 |
| NRC Officer: | John Mackinnon |
| Last Updated: | Nov 14, 2005 |
| 42140 - NRC Website
| |