ENS 42851: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
Line 16: Line 16:
| event date = 09/20/2006 CDT
| event date = 09/20/2006 CDT
| last update date = 09/21/2006
| last update date = 09/21/2006
| title = Irradiator Source Temporarily Stuck In The Exposed Position
| title = Irradiator Source Temporarily Stuck in the Exposed Position
| event text = On the night of 8/28- 8/29/2006 the large irradiator was being used for an all night procedure.  The principle investigator for the irradiator was present to conclude the operation on the morning of August 29.  At the time designated for source retraction, the irradiator source in fact did not retract to the stowed position.  The source actuation system uses air pressure to expose the source and spring force to stow the source.  The principle investigator tried to house the source by operating the "override" button.  The source remained exposed.  After approximately 15 minutes the source returned to the housed condition with no operator action. The irradiator will not be used until J.L. Shepard [the manufacturer] is contacted and the cause identified and corrected.  The source is currently stowed.  
| event text = On the night of 8/28- 8/29/2006 the large irradiator was being used for an all night procedure.  The principle investigator for the irradiator was present to conclude the operation on the morning of August 29.  At the time designated for source retraction, the irradiator source in fact did not retract to the stowed position.  The source actuation system uses air pressure to expose the source and spring force to stow the source.  The principle investigator tried to house the source by operating the "override" button.  The source remained exposed.  After approximately 15 minutes the source returned to the housed condition with no operator action. The irradiator will not be used until J.L. Shepard [the manufacturer] is contacted and the cause identified and corrected.  The source is currently stowed.  
The irradiator is an 8800 Curie  Cs-137 self shielded irradiator.
The irradiator is an 8800 Curie  Cs-137 self shielded irradiator.

Revision as of 22:18, 1 March 2018

ENS 42851 +/-
Where
University Of Iowa
Iowa City, Iowa (NRC Region 3)
License number: 0037-1-52-Aab
Organization: Iowa Department Of Public Health
Reporting
Agreement State
Time - Person (Reporting Time:+12.28 h0.512 days <br />0.0731 weeks <br />0.0168 months <br />)
Opened: Dan Mcghee
17:17 Sep 20, 2006
NRC Officer: Jason Kozal
Last Updated: Sep 21, 2006
42851 - NRC Website
Loading map...