Line 16: Line 16:
| event date = 01/23/2007 12:44 EST
| event date = 01/23/2007 12:44 EST
| last update date = 01/23/2007
| last update date = 01/23/2007
| title = Reactor Trip Due To Feedwater Regulating Valve Failure
| title = Reactor Trip Due to Feedwater Regulating Valve Failure
| event text = An automatic reactor scram occurred resulting from loop #2 steam generator low level.  The main feedwater regulating valve 2-FCV-3-48 failed closed when the air supply line to the valve severed.  A significant leak had been identified and efforts to repair had been initiated.  All systems responded as designed.  The plant is stable on Auxiliary Feed Water (AFW) and steam generator cooling [to the condenser via steam dump valve] while repairs to the failed air line are planned.
| event text = An automatic reactor scram occurred resulting from loop #2 steam generator low level.  The main feedwater regulating valve 2-FCV-3-48 failed closed when the air supply line to the valve severed.  A significant leak had been identified and efforts to repair had been initiated.  All systems responded as designed.  The plant is stable on Auxiliary Feed Water (AFW) and steam generator cooling [to the condenser via steam dump valve] while repairs to the failed air line are planned.
All control rods fully inserted into the core.  No steam generator or pressurizer relief valves lifted during the transient.  The licensee notified the NRC Resident Inspector.
All control rods fully inserted into the core.  No steam generator or pressurizer relief valves lifted during the transient.  The licensee notified the NRC Resident Inspector.

Latest revision as of 22:17, 1 March 2018

ENS 43115 +/-
Where
Sequoyah Tennessee Valley Authority icon.png
Tennessee (NRC Region 2)
Reporting
10 CFR 50.72(b)(2)(iv)(B), RPS Actuation

10 CFR 50.72(b)(3)(iv)(A), System Actuation
Time - Person (Reporting Time:+-3 h-0.125 days <br />-0.0179 weeks <br />-0.00411 months <br />)
Opened: Larry Pruett
14:44 Jan 23, 2007
NRC Officer: Bill Gott
Last Updated: Jan 23, 2007
43115 - NRC Website