ENS 45321: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 08/25/2009 14:30 EDT | | event date = 08/25/2009 14:30 EDT | ||
| last update date = 09/01/2009 | | last update date = 09/01/2009 | ||
| title = Agreement State - Surface Contamination Levels | | title = Agreement State - Surface Contamination Levels in Excess of Limits | ||
| event text = The following was received via facsimile: | | event text = The following was received via facsimile: | ||
An empty Type B, 30 gallon drum container was shipped on August 20, 2009 via public carrier from NSSI Sources and Services Inc. from Houston, Texas. It was delivered on August 25, 2009 to a Los Alamos National Laboratory (LANL) job site within a building at Penn State University in State College, PA. The shipping container was found to have external removable alpha contamination in excess of the US DOT limits noted in 49 CFR 173. LANL personnel informed their management and the carrier. Steps were also taken to verify that the contamination did not originate at Penn State. The individual truck that delivered the package to Penn State was surveyed by LANL personnel at about 2100 on 8/25/09. No contamination was found in the truck or the driver's area. There was no risk to any personnel at this facility due to this event. The first wipe found removable alpha contamination well in excess of the 2.2 dpm/centimeter squared DOT limit. After hours of decon, the removable contamination on the shipping containers was still over the limit. Onsite measurements noted little or no associated gamma radiation, and a sample was sent to LANL for alpha spectrum analysis. The material has been tentatively identified as curium-244 (Cm-244). | An empty Type B, 30 gallon drum container was shipped on August 20, 2009 via public carrier from NSSI Sources and Services Inc. from Houston, Texas. It was delivered on August 25, 2009 to a Los Alamos National Laboratory (LANL) job site within a building at Penn State University in State College, PA. The shipping container was found to have external removable alpha contamination in excess of the US DOT limits noted in 49 CFR 173. LANL personnel informed their management and the carrier. Steps were also taken to verify that the contamination did not originate at Penn State. The individual truck that delivered the package to Penn State was surveyed by LANL personnel at about 2100 on 8/25/09. No contamination was found in the truck or the driver's area. There was no risk to any personnel at this facility due to this event. The first wipe found removable alpha contamination well in excess of the 2.2 dpm/centimeter squared DOT limit. After hours of decon, the removable contamination on the shipping containers was still over the limit. Onsite measurements noted little or no associated gamma radiation, and a sample was sent to LANL for alpha spectrum analysis. The material has been tentatively identified as curium-244 (Cm-244). |
Latest revision as of 22:11, 1 March 2018
Where | |
---|---|
Pennsylvania State University State College, Pennsylvania (NRC Region 1) | |
Organization: | Pa Bureau Of Radiation Protection |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+171.97 h7.165 days <br />1.024 weeks <br />0.236 months <br />) | |
Opened: | David Allard 22:28 Sep 1, 2009 |
NRC Officer: | Charles Teal |
Last Updated: | Sep 1, 2009 |
45321 - NRC Website
| |