ENS 46770: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 04/18/2011 CDT
| event date = 04/18/2011 CDT
| last update date = 04/20/2011
| last update date = 04/20/2011
| title = Agreement State Report - Malfunctioning Gauge Involving A 2 Curie Cesium-137 Source
| title = Agreement State Report - Malfunctioning Gauge Involving a 2 Curie Cesium-137 Source
| event text = The following was received from the state via fax:
| event text = The following was received from the state via fax:
On April 18, 2011, a gauge malfunction occurred at the licensee's facility during a device installation on a process vessel.  When the 2 Curie Cesium-137 source was inserted into the vessel, the chain connecting the source to the nuclear gauge broke allowing the source to travel to the bottom of the insertion tube.  The source being at the  bottom of the insertion tube is its normal operating position.  A radiation survey was conducted by the licensee indicating radiation levels were normal.  The device was removed from the vessel, [and] the source [was] retrieved from inside of the vessel.  The device and the 2 sources were taken by the service company to their facility for repair.  There was no additional radiation exposure to any members of the general public or radiation workers due to this incident.  Gauge information:  TFS model 5220 containing (2) 2-Ci Cesium-137 sources. Device SN: B-36. Source SNs: MB-3946 and MB 3956.   
On April 18, 2011, a gauge malfunction occurred at the licensee's facility during a device installation on a process vessel.  When the 2 Curie Cesium-137 source was inserted into the vessel, the chain connecting the source to the nuclear gauge broke allowing the source to travel to the bottom of the insertion tube.  The source being at the  bottom of the insertion tube is its normal operating position.  A radiation survey was conducted by the licensee indicating radiation levels were normal.  The device was removed from the vessel, [and] the source [was] retrieved from inside of the vessel.  The device and the 2 sources were taken by the service company to their facility for repair.  There was no additional radiation exposure to any members of the general public or radiation workers due to this incident.  Gauge information:  TFS model 5220 containing (2) 2-Ci Cesium-137 sources. Device SN: B-36. Source SNs: MB-3946 and MB 3956.   

Latest revision as of 22:07, 1 March 2018

ENS 46770 +/-
Where
Bp Products North America
Texas City, Texas (NRC Region 4)
License number: L00254
Organization: Texas Department Of Health
Reporting
Agreement State
Time - Person (Reporting Time:+60.63 h2.526 days <br />0.361 weeks <br />0.0831 months <br />)
Opened: Karen Blanchard
17:38 Apr 20, 2011
NRC Officer: Joe O'Hara
Last Updated: Apr 20, 2011
46770 - NRC Website