ENS 49348: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 09/13/2013 CDT | | event date = 09/13/2013 CDT | ||
| last update date = 09/16/2013 | | last update date = 09/16/2013 | ||
| title = Agreement State Report - Radiography Camera Source Fails | | title = Agreement State Report - Radiography Camera Source Fails to Retract | ||
| event text = On September 16, 2013, the licensee notified the Agency [Texas Department of Health] that on September 13, 2013, one of its radiography crews had been unable to retract a Iridium-192 source back into a SPEC 150 exposure device at a temporary work site in Tilden, Texas. Following the first exposure of the morning, the source pigtail would not retract fully into the device. An authorized person performed the source retrieval. This individual received 20 millirem and the individual that assisted him received 10 millirem. No member of the public received any exposure as a result of this event. | | event text = On September 16, 2013, the licensee notified the Agency [Texas Department of Health] that on September 13, 2013, one of its radiography crews had been unable to retract a Iridium-192 source back into a SPEC 150 exposure device at a temporary work site in Tilden, Texas. Following the first exposure of the morning, the source pigtail would not retract fully into the device. An authorized person performed the source retrieval. This individual received 20 millirem and the individual that assisted him received 10 millirem. No member of the public received any exposure as a result of this event. | ||
The licensee's radiation safety officer inspected the inside of the source guide tube using a tube scope and found that the coil in the source guide tube was pushed out into the inside of the tube where the connector fitting was crimped onto the guide tube. The connector had just been replaced by a local service company. An investigation into this event is ongoing. Information will be provided as it is obtained in accordance with SA-300. | The licensee's radiation safety officer inspected the inside of the source guide tube using a tube scope and found that the coil in the source guide tube was pushed out into the inside of the tube where the connector fitting was crimped onto the guide tube. The connector had just been replaced by a local service company. An investigation into this event is ongoing. Information will be provided as it is obtained in accordance with SA-300. |
Revision as of 20:59, 1 March 2018
Where | |
---|---|
Mistras Group Inc. La Porte, Texas (NRC Region 4) | |
License number: | Lo6369 |
Organization: | Texas Department Of Health |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+80.97 h3.374 days <br />0.482 weeks <br />0.111 months <br />) | |
Opened: | Karen Blanchard 13:58 Sep 16, 2013 |
NRC Officer: | Pete Snyder |
Last Updated: | Sep 16, 2013 |
49348 - NRC Website | |