ENS 51105: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 05/29/2015 22:10 YDT | | event date = 05/29/2015 22:10 YDT | ||
| last update date = 05/30/2015 | | last update date = 05/30/2015 | ||
| title = Radiography Source Stuck | | title = Radiography Source Stuck in Guide Tube | ||
| event text = The equipment supporting the collimator, guide tube, and extension tube fell from a height of 9 feet causing the guide tube to become entangled in the piping below. [The guide tubes fell on equipment below and the short radius bends prevented source retrieval.] | | event text = The equipment supporting the collimator, guide tube, and extension tube fell from a height of 9 feet causing the guide tube to become entangled in the piping below. [The guide tubes fell on equipment below and the short radius bends prevented source retrieval.] | ||
Equipment Involved: | Equipment Involved: |
Latest revision as of 21:47, 1 March 2018
Where | |
---|---|
Mistras Group Prudhoe Bay, Alaska (NRC Region 4) | |
License number: | 12-16559-02 |
Organization: | Mistras Group |
Reporting | |
10 CFR 30.50(b)(2), Licensed Material Protection Equipment Failure | |
Time - Person (Reporting Time:+9.48 h0.395 days <br />0.0564 weeks <br />0.013 months <br />) | |
Opened: | Jeremy Dunning 15:39 May 30, 2015 |
NRC Officer: | Mark Abramovitz |
Last Updated: | May 30, 2015 |
51105 - NRC Website
| |