ENS 51747: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by Mark Hawes) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
| event date = 02/20/2016 03:30 EST | | event date = 02/20/2016 03:30 EST | ||
| last update date = 02/20/2016 | | last update date = 02/20/2016 | ||
| title = Degraded Condition Discovered | | title = Degraded Condition Discovered on Pressurizer Safety Relief Valve Weld | ||
| event text = During the CCNPP [Calvert Cliff Nuclear Power Plant] Unit 1 Refueling, [an ultrasonic test] examination of the Unit 1 dissimilar metal weld (DMW) of the pressurizer safety relief valve RV-201 safe end weld found an indication that is approximately 80 percent though-wall, inside diameter connected axial flaw in weld #4-SR-1006-1. | | event text = During the CCNPP [Calvert Cliff Nuclear Power Plant] Unit 1 Refueling, [an ultrasonic test] examination of the Unit 1 dissimilar metal weld (DMW) of the pressurizer safety relief valve RV-201 safe end weld found an indication that is approximately 80 percent though-wall, inside diameter connected axial flaw in weld #4-SR-1006-1. | ||
This is an ASME Class 1 component and Unit 1 has entered the requirements of Technical Requirements Manual (TRM) 15.4.3.A. | This is an ASME Class 1 component and Unit 1 has entered the requirements of Technical Requirements Manual (TRM) 15.4.3.A. |
Latest revision as of 20:45, 1 March 2018
Where | |
---|---|
Calvert Cliffs Maryland (NRC Region 1) | |
Reporting | |
10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
LER: | 05000317/LER-2016-002 |
Time - Person (Reporting Time:+0.7 h0.0292 days <br />0.00417 weeks <br />9.5886e-4 months <br />) | |
Opened: | Ervin Lyson 09:12 Feb 20, 2016 |
NRC Officer: | Howie Crouch |
Last Updated: | Feb 20, 2016 |
51747 - NRC Website
| |