| title = Agreement State Report - Shutter Failure To Close
| title = Agreement State Report - Shutter Failure to Close
| event text = The following was excerpted from information received from the State of New Jersey by email:
| event text = The following was excerpted from information received from the State of New Jersey by email:
Event Narrative: On November 7, 2016, during the six-month shutter checks, the pneumatically operated shutter on the Vega source holder Phillips 66-Bayway Tag # PBL002 (source capsule S/N 0321CG)  failed to close when tested.  Several attempts were made wherein the shutter position indicator seemed to move slightly.  It was concluded that the issue was not a failure of the air system controlling the pneumatic shutter actuator.  The manufacturer was contacted to assess the problem.
Event Narrative: On November 7, 2016, during the six-month shutter checks, the pneumatically operated shutter on the Vega source holder Phillips 66-Bayway Tag # PBL002 (source capsule S/N 0321CG)  failed to close when tested.  Several attempts were made wherein the shutter position indicator seemed to move slightly.  It was concluded that the issue was not a failure of the air system controlling the pneumatic shutter actuator.  The manufacturer was contacted to assess the problem.

Latest revision as of 20:43, 1 March 2018

ENS 52351 +/-
Where
Phillips 66
Linden, New Jersey (NRC Region 1)
License number: 506897
Organization: Nj Rad Prot And Rel Prevention Pgm
Reporting
Agreement State
Time - Person (Reporting Time:+-1.92 h-0.08 days <br />-0.0114 weeks <br />-0.00263 months <br />)
Opened: Ed Truskowski
16:50 Nov 7, 2016
NRC Officer: Vince Klco
Last Updated: Dec 1, 2016