ML20249C718: Difference between revisions
StriderTol (talk | contribs) (StriderTol Bot insert) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| (One intermediate revision by the same user not shown) | |||
| Line 13: | Line 13: | ||
| document type = CORRESPONDENCE-LETTERS, OUTGOING CORRESPONDENCE | | document type = CORRESPONDENCE-LETTERS, OUTGOING CORRESPONDENCE | ||
| page count = 4 | | page count = 4 | ||
| project = TAC:M99526 | |||
| stage = Other | |||
}} | }} | ||
=Text= | =Text= | ||
{{#Wiki_filter:- _ _ _ _ . _ _ _ - - _ _ - _ _ _ _ - _ _ - - _ _ . | {{#Wiki_filter:- _ _ _ _. _ _ _ - - _ _ - _ _ _ _ - _ _ - - _ _. | ||
r) | r)'' | ||
June 25, 1998 l | June 25, 1998 l | ||
r | r | ||
- 4 Mr. Lee Liu - | |||
.ChIirmin of ths Boird and Chief Executive Officer - | |||
. lES Utilities Inc. | |||
200 First Street, SE. | 200 First Street, SE. | ||
~ P.O. Box 351 - | |||
Cedar Rapids, IA 52406-0351 - | Cedar Rapids, IA 52406-0351 - | ||
| Line 30: | Line 33: | ||
==Dear Mr. Liu:== | ==Dear Mr. Liu:== | ||
By {{letter dated|date=May 16, 1997|text=letter dated May 16,1997}}, IES Utilities Inc. submitted Revision:18 of the Duane Amold | |||
By letter dated May 16,1997, IES Utilities Inc. submitted Revision:18 of the Duane Amold | ~ Energy Center (DAEC) Quality Assurance Program Description. Included in this revision was a change to the Updated Final Safety Analysis Report (UFSAR) Table 3.2-1, where the | ||
" Equivalent ASME B&PV Code Class" column for the emergency service water piping classification was changed from "3" to " '." _During its review, the NRC staff expressed concern that this column could be misleading even though footnote "h" in the table describes this column as an "Information Only" column. Based on discussions with the staff, IES Utilities Inc. made a revised submittal on June 11,1998, which stated that the " Equivalent ASME B&PV Code Class" column will be deleted from UFSAR Table 3.2-1 in the next UFSAR update scheduied for November 1998. | |||
The staff has completed its review and determined that Revision 18 of the DAEC QAPD as - | The staff has completed its review and determined that Revision 18 of the DAEC QAPD as - | ||
' updated by the June 11,1998 submittal, continues to comply with the criteria of Appendix B to 10 CFR Part 50, and is therefore acceptable. | |||
If you should have any questions regarding this matter, please contact me at (301) 415-1373. | If you should have any questions regarding this matter, please contact me at (301) 415-1373. | ||
i Sincerely, Original signed by: | i Sincerely, Original signed by: | ||
Richard J. Laufer, Project Manager | Richard J. Laufer, Project Manager Project Directorate 111-3 Division of Reactor Projects lil/lV Office of Nuclear Reactor Regulation Docket No. 50-331 | ||
Docket No. 50-331 | { | ||
cc: See next page f | s cc: See next page f h h ky QQ Distnbution : | ||
Distnbution : | N h 8 | ||
Docket File | ) | ||
Docket File GGrant, Rlli. | |||
PD3-3 Reading' | EGA1 | ||
- PUBLIC ACRS OGC PD3-3 Reading' RBellamy DOCUMENT NAME: G:\\DUANEARN\\DA99526.LTR | |||
l DATE' | *See Previous Concurrence l | ||
To receive.a copy of this document, indicate in the box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy OFFICE PM:PD33 L | |||
LA:PD33 - | |||
f | Q., EMEB C HQMB C | ||
NAME RLaufer W EBamhill Pfe. | |||
DTerao* | |||
SBlack* | |||
l DATE' G/d/98 L,(l698 6/ 24/98 6/24/98 OFFICIAL RECORD COPY 9907010083 990625 PDR ADOCK 05000331 f | |||
-.-----._.--________I____----__ | |||
I | I | ||
~ | |||
June 25, 1998 | June 25, 1998 Ch:irmin of the Boird cnd Chief Ex::cutiva Officer j | ||
IES Utilities Inc. | |||
cnd Chief Ex::cutiva Officer j | . 200 First Street, SE. | ||
P.O. Box 351 Cedar Rapids, lA 52406-0351 | P.O. Box 351 Cedar Rapids, lA 52406-0351 | ||
| Line 63: | Line 69: | ||
==Dear Mr. Liu:== | ==Dear Mr. Liu:== | ||
By {{letter dated|date=May 16, 1997|text=letter dated May 16,1997}}, IES Utilities Inc. submitted Revision 18 of the Duane Amold Energy Center (DAEC) Quality Assurance Program Description. Included in this revision was a change to the Updated Final Safety Analysis Report (UFSAR) Table 3.2-1, where the | |||
By letter dated May 16,1997, IES Utilities Inc. submitted Revision 18 of the Duane Amold Energy Center (DAEC) Quality Assurance Program Description. Included in this revision was a change to the Updated Final Safety Analysis Report (UFSAR) Table 3.2-1, where the | " Equivalent ASME B&PV Code Class" column for the emergency service water piping classification was changed from *3" to "." During its review, the NRC staff expressed concem | ||
' that this column could be misleading even though footnote "h" in the table describes this column as an "Information Only" column. Based on discussions with the staff, IES Utilities Inc. made a revised submittal on June 11,1998, which stated that the " Equivalent ASME B&PV Code Class" column will be deleted from UFSAR Table 3.2-1 in the next UFSAR update scheduled for November 1998. | |||
The staff has completed its review and determined that Revision 18 of the DAEC QAPD as | The staff has completed its review and determined that Revision 18 of the DAEC QAPD as | ||
. updated by the June 11,1998 submittal, continues to ::omply with the. criteria of Appendix B to 10 CFR Part 50, and is therefore acceptable. | |||
If you should have any questions regarding this matter, please contact me at (301) 415-1373. | If you should have any questions regarding this matter, please contact me at (301) 415-1373. | ||
Sincerely, Original signed by: | Sincerely, Original signed by: | ||
Richard J. Laufer, Project Manager Project Directorate 111-3 Division of Reactor Projects Ill/lV Office of Nuclear Reactor Regulation Docket No. 50-331 cc: See next page Distabution : | Richard J. Laufer, Project Manager Project Directorate 111-3 Division of Reactor Projects Ill/lV Office of Nuclear Reactor Regulation Docket No. 50-331 cc: See next page Distabution : | ||
Docket File - | Docket File - | ||
DOCUMENT NAME: G:\DUANEARN\DA99526.LTR | GGrant, Rill EGA1 PUBLIC ACRS-OGC PD3-3 Reading RBellamy - | ||
DATE | DOCUMENT NAME: G:\\DUANEARN\\DA99526.LTR | ||
'*See Previous Concurrence To receive a copy of this document, indicata in the box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy OFFICE PM:PD33 L | |||
LA:PD33 0., EMTB C HQMB C | |||
NAME RLaufer W EBamhill Pf4-DTerso* | |||
SBlack* | |||
DATE C/t5/98 b@98 6/24/98 6/24/98 OFFICIAL RECORD COPY m.___ | |||
p nct:oq y | p nct:oq y | ||
'4 UNITED STATES g | |||
j NUCLEAR REGULATORY COMMISSION l | |||
g WASHINGTON, D.C. 20086 0001 s ******, | |||
June 25, 1998 Mr. Lee Liu Chairman of the Board and Chief Executive Officer IES Utilities Inc. | June 25, 1998 Mr. Lee Liu Chairman of the Board and Chief Executive Officer IES Utilities Inc. | ||
200 First Street, SE. | 200 First Street, SE. | ||
| Line 87: | Line 98: | ||
==Dear Mr. Liu:== | ==Dear Mr. Liu:== | ||
By {{letter dated|date=May 16, 1997|text=letter dated May 16,1997}}, IES Utilities Inc. submitted Revision 18 of the Duane Amold Energy Center (DAEC) Quality Assurance Program Description. Included in this revision w'as a i | |||
By letter dated May 16,1997, IES Utilities Inc. submitted Revision 18 of the Duane Amold Energy Center (DAEC) Quality Assurance Program Description. Included in this revision w'as a | change to the Updated Final Safety Analysis Report (UFSAR) Table 3.2-1, where the | ||
" Equivalent ASME B&PV Code Class" column for the emergency service water piping classification was changed from '3" to *." During its review, the NRC staff expressed concem that this column could be misleading even though footnote "h" in the table describes this column as an "Information Only" column. Based on discussions with the staff, IES Utilities Inc. made a l | |||
as an "Information Only" column. Based on discussions with the staff, IES Utilities Inc. made a | revised submittal on June 11,1998, which stated that the " Equivalent ASME B&PV Code Class" column will be deleted from UFSAR Table 3.2-1 in the next UFSAR update scheduled for 1 | ||
column will be deleted from UFSAR Table 3.2-1 in the next UFSAR update scheduled for | November 1998. | ||
l The staff has completed its review and determined that Revision 18 of the DAEC QAPD as' updated by the June 11,1998 submittel, continues to comply with the criteria of Appendix B to l | |||
10 CFR Part 50, and is therefore acceptable. | |||
4 If you should have any questions regarding this matter, please contact me at (301) 415-1373. | 4 If you should have any questions regarding this matter, please contact me at (301) 415-1373. | ||
Sincerely, l | Sincerely, l | ||
Richard J. Laufer, Project Manager l | |||
Project Directorate 111-3 l | |||
Division of Reactor Projects lil/IV l | |||
Office of Nuclear Reactor Regulation l | |||
Docket No. 50-331 cc: See next page t | |||
__ w | |||
,o Lee Liu Duane Amold Energy Center IES Utilities Inc. | |||
cc: | cc: | ||
Jack Newman, Esquire Al Gutterman, Esquire Morgan, Lewis, & Bockius 1800 M Street, NW. | Jack Newman, Esquire Al Gutterman, Esquire Morgan, Lewis, & Bockius 1800 M Street, NW. | ||
Washington, DC 20036-5869 Chairman, Linn County Board of Supervisors Cedar Rapids, IA 52406 IES Utilities Inc. | Washington, DC 20036-5869 Chairman, Linn County Board of Supervisors Cedar Rapids, IA 52406 IES Utilities Inc. | ||
ATTN: Gary Van Middlesworth Plant Superintendent, Nuclear 3277 DAEC Road Palo,IA 52324 John F. Franz, Jr. | ATTN: Gary Van Middlesworth Plant Superintendent, Nuclear 3277 DAEC Road Palo,IA 52324 John F. Franz, Jr. | ||
i Vice President, Nuclear I | |||
Lisle, IL 60532-4531 Parween Baig | Duane Amold Energy Center 3277 DAEC Road Palo,IA 52324 Ken Peveler Manager of Regulatory Performance Duane Arnold Energy Center 3277 DAEC Road Palo,IA 52324 U.S. Nuclear Regulatory Commission Resident inspector's Office Rural Route #1 Palo,IA 52324 I | ||
Utilities Division Iowa Department of Commerce Lucas Office Building,5th floor Des Moines,IA 50319 | Regional Administrator, Rill | ||
E - _ _ -- _ _ __-_- _ -__ | ' U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4531 l | ||
Parween Baig Utilities Division Iowa Department of Commerce Lucas Office Building,5th floor Des Moines,IA 50319 E - _ _ -- _ _ __-_- _ -__ | |||
u}} | |||
Latest revision as of 13:49, 30 November 2024
| ML20249C718 | |
| Person / Time | |
|---|---|
| Site: | Duane Arnold |
| Issue date: | 06/25/1998 |
| From: | Richard Laufer NRC (Affiliation Not Assigned) |
| To: | Leslie Liu IES UTILITIES INC., (FORMERLY IOWA ELECTRIC LIGHT |
| References | |
| TAC-M99526, NUDOCS 9807010083 | |
| Download: ML20249C718 (4) | |
Text
- _ _ _ _. _ _ _ - - _ _ - _ _ _ _ - _ _ - - _ _.
r)
June 25, 1998 l
r
- 4 Mr. Lee Liu -
.ChIirmin of ths Boird and Chief Executive Officer -
. lES Utilities Inc.
200 First Street, SE.
~ P.O. Box 351 -
Cedar Rapids, IA 52406-0351 -
SUBJECT:
REVIEW OF REVISION 18 OF THE QUALITY ASSURANCE PROGRAM DESCRIPTION '- DUANE ARNOLD ENERGY CENTER (TAC NO. M99526)
Dear Mr. Liu:
By letter dated May 16,1997, IES Utilities Inc. submitted Revision:18 of the Duane Amold
~ Energy Center (DAEC) Quality Assurance Program Description. Included in this revision was a change to the Updated Final Safety Analysis Report (UFSAR) Table 3.2-1, where the
" Equivalent ASME B&PV Code Class" column for the emergency service water piping classification was changed from "3" to " '." _During its review, the NRC staff expressed concern that this column could be misleading even though footnote "h" in the table describes this column as an "Information Only" column. Based on discussions with the staff, IES Utilities Inc. made a revised submittal on June 11,1998, which stated that the " Equivalent ASME B&PV Code Class" column will be deleted from UFSAR Table 3.2-1 in the next UFSAR update scheduied for November 1998.
The staff has completed its review and determined that Revision 18 of the DAEC QAPD as -
' updated by the June 11,1998 submittal, continues to comply with the criteria of Appendix B to 10 CFR Part 50, and is therefore acceptable.
If you should have any questions regarding this matter, please contact me at (301) 415-1373.
i Sincerely, Original signed by:
Richard J. Laufer, Project Manager Project Directorate 111-3 Division of Reactor Projects lil/lV Office of Nuclear Reactor Regulation Docket No. 50-331
{
s cc: See next page f h h ky QQ Distnbution :
N h 8
)
Docket File GGrant, Rlli.
EGA1
- PUBLIC ACRS OGC PD3-3 Reading' RBellamy DOCUMENT NAME: G:\\DUANEARN\\DA99526.LTR
- See Previous Concurrence l
To receive.a copy of this document, indicate in the box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy OFFICE PM:PD33 L
LA:PD33 -
Q., EMEB C HQMB C
NAME RLaufer W EBamhill Pfe.
DTerao*
SBlack*
l DATE' G/d/98 L,(l698 6/ 24/98 6/24/98 OFFICIAL RECORD COPY 9907010083 990625 PDR ADOCK 05000331 f
-.-----._.--________I____----__
I
~
June 25, 1998 Ch:irmin of the Boird cnd Chief Ex::cutiva Officer j
IES Utilities Inc.
. 200 First Street, SE.
P.O. Box 351 Cedar Rapids, lA 52406-0351
SUBJECT:
REVIEW OF REVISION 18 OF THE QUALITY ASSURANCE PROGRAM DESCRIPTION - DUANE ARNOLD ENERGY CENTER (TAC NO. M99526)
Dear Mr. Liu:
By letter dated May 16,1997, IES Utilities Inc. submitted Revision 18 of the Duane Amold Energy Center (DAEC) Quality Assurance Program Description. Included in this revision was a change to the Updated Final Safety Analysis Report (UFSAR) Table 3.2-1, where the
" Equivalent ASME B&PV Code Class" column for the emergency service water piping classification was changed from *3" to "." During its review, the NRC staff expressed concem
' that this column could be misleading even though footnote "h" in the table describes this column as an "Information Only" column. Based on discussions with the staff, IES Utilities Inc. made a revised submittal on June 11,1998, which stated that the " Equivalent ASME B&PV Code Class" column will be deleted from UFSAR Table 3.2-1 in the next UFSAR update scheduled for November 1998.
The staff has completed its review and determined that Revision 18 of the DAEC QAPD as
. updated by the June 11,1998 submittal, continues to ::omply with the. criteria of Appendix B to 10 CFR Part 50, and is therefore acceptable.
If you should have any questions regarding this matter, please contact me at (301) 415-1373.
Sincerely, Original signed by:
Richard J. Laufer, Project Manager Project Directorate 111-3 Division of Reactor Projects Ill/lV Office of Nuclear Reactor Regulation Docket No. 50-331 cc: See next page Distabution :
Docket File -
GGrant, Rill EGA1 PUBLIC ACRS-OGC PD3-3 Reading RBellamy -
DOCUMENT NAME: G:\\DUANEARN\\DA99526.LTR
'*See Previous Concurrence To receive a copy of this document, indicata in the box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy OFFICE PM:PD33 L
LA:PD33 0., EMTB C HQMB C
NAME RLaufer W EBamhill Pf4-DTerso*
SBlack*
DATE C/t5/98 b@98 6/24/98 6/24/98 OFFICIAL RECORD COPY m.___
p nct:oq y
'4 UNITED STATES g
j NUCLEAR REGULATORY COMMISSION l
g WASHINGTON, D.C. 20086 0001 s ******,
June 25, 1998 Mr. Lee Liu Chairman of the Board and Chief Executive Officer IES Utilities Inc.
200 First Street, SE.
P.O. Box 351 Cedar Rapids, IA 52406-0351
SUBJECT:
REVIEW OF REVISION 18 OF THE QUALITY ASSURANCE PROGRAM DESCRIPTION - DUANE ARNOLD ENERGY CENTER (TAC NO. M99526)
Dear Mr. Liu:
By letter dated May 16,1997, IES Utilities Inc. submitted Revision 18 of the Duane Amold Energy Center (DAEC) Quality Assurance Program Description. Included in this revision w'as a i
change to the Updated Final Safety Analysis Report (UFSAR) Table 3.2-1, where the
" Equivalent ASME B&PV Code Class" column for the emergency service water piping classification was changed from '3" to *." During its review, the NRC staff expressed concem that this column could be misleading even though footnote "h" in the table describes this column as an "Information Only" column. Based on discussions with the staff, IES Utilities Inc. made a l
revised submittal on June 11,1998, which stated that the " Equivalent ASME B&PV Code Class" column will be deleted from UFSAR Table 3.2-1 in the next UFSAR update scheduled for 1
November 1998.
l The staff has completed its review and determined that Revision 18 of the DAEC QAPD as' updated by the June 11,1998 submittel, continues to comply with the criteria of Appendix B to l
10 CFR Part 50, and is therefore acceptable.
4 If you should have any questions regarding this matter, please contact me at (301) 415-1373.
Sincerely, l
Richard J. Laufer, Project Manager l
Project Directorate 111-3 l
Division of Reactor Projects lil/IV l
Office of Nuclear Reactor Regulation l
Docket No. 50-331 cc: See next page t
__ w
,o Lee Liu Duane Amold Energy Center IES Utilities Inc.
cc:
Jack Newman, Esquire Al Gutterman, Esquire Morgan, Lewis, & Bockius 1800 M Street, NW.
Washington, DC 20036-5869 Chairman, Linn County Board of Supervisors Cedar Rapids, IA 52406 IES Utilities Inc.
ATTN: Gary Van Middlesworth Plant Superintendent, Nuclear 3277 DAEC Road Palo,IA 52324 John F. Franz, Jr.
i Vice President, Nuclear I
Duane Amold Energy Center 3277 DAEC Road Palo,IA 52324 Ken Peveler Manager of Regulatory Performance Duane Arnold Energy Center 3277 DAEC Road Palo,IA 52324 U.S. Nuclear Regulatory Commission Resident inspector's Office Rural Route #1 Palo,IA 52324 I
Regional Administrator, Rill
' U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, IL 60532-4531 l
Parween Baig Utilities Division Iowa Department of Commerce Lucas Office Building,5th floor Des Moines,IA 50319 E - _ _ -- _ _ __-_- _ -__
u