The source retrieval team found that the drive cable connector had broken just above the crimp causing the source and pigtail to become disconnected from the cable. The licensee reports that the connector lot number is FW-21, and it was put into service on 12/18/2022. | The source retrieval team found that the drive cable connector had broken just above the crimp causing the source and pigtail to become disconnected from the cable. The licensee reports that the connector lot number is FW-21, and it was put into service on 12/18/2022. | ||
Ohio Item Number: OH230001 | Ohio Item Number: OH230001 | ||
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2023/ | | URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2023/20230301en.html#en56375 | ||
}} | }} | ||
{{ENS-Nav}} | {{ENS-Nav}} |
Latest revision as of 08:30, 1 March 2023
Where | |
---|---|
Acuren Inspection Inc. Adba Tei West Chester, Ohio (NRC Region 3) | |
License number: | 03320990006 |
Organization: | Ohio Bureau Of Radiation Protection |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+32.95 h1.373 days <br />0.196 weeks <br />0.0451 months <br />) | |
Opened: | Stephen James 13:57 Feb 21, 2023 |
NRC Officer: | Kerby Scales |
Last Updated: | Feb 21, 2023 |
56375 - NRC Website | |