05000282/LER-1998-002, Forwards LER 98-002-00 Re Control Room Unfiltered Air Inleakage Found to Be Excessive.Util Made Two New NRC Commitments,Indicated as Corrective Action Statement in Italics in Rept: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot change)
(StriderTol Bot change)
Line 1: Line 1:
{{Adams
#REDIRECT [[05000282/LER-1998-002, Forwards Proprietary Rept, Metallurgical Investigation & Root Cause Assessment of Part Length CRDM Housing Motor Tube Cracking at PINGP Unit 2, in Response to RAI Dtd 980218. Suppl Rept for LER 98-02 Will Also Be Delayed.Rept W]]
| number = ML20203B629
| issue date = 02/18/1998
| title = Forwards LER 98-002-00 Re Control Room Unfiltered Air Inleakage Found to Be Excessive.Util Made Two New NRC Commitments,Indicated as Corrective Action Statement in Italics in Rept
| author name = Sorensen J
| author affiliation = NORTHERN STATES POWER CO.
| addressee name =
| addressee affiliation = NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
| docket = 05000282
| license number =
| contact person =
| document report number = NUDOCS 9802240357
| package number = ML20203B633
| document type = CORRESPONDENCE-LETTERS, INCOMING CORRESPONDENCE
| page count = 1
}}
{{LER
| Title = Forwards LER 98-002-00 Re Control Room Unfiltered Air Inleakage Found to Be Excessive.Util Made Two New NRC Commitments,Indicated as Corrective Action Statement in Italics in Rept
| Plant =
| Reporting criterion =
| Power level =
| Mode =
| Docket = 05000282
| LER year = 2098
| LER number = 2
| LER revision =
| Event date =
| Report date =
| ENS =
| abstract =
}}
 
=text=
{{#Wiki_filter:- - - _ _ _ .                                              ._-
Northern States Power Company Prairie Island Nuclear Generating Plant 1717 Wakonado Dr. East Welch, Minnesota 55089 February 18,1998                                                      10 CFR Part 50 Section 50.73 U S Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 License Nos. DPR-42 50-306                          DPR-60 LER 1-98-02 Control Room Unfiltered Air Inteakage Found to be Excessive The Licensee Event Report for this occurrence is attached. In the report, we made two new NRC commitments, indicated as the Corrective Action statement in italics.
Please contact us if you require additional information related to this event.
Joel P Sorensen Plant Manager Pra';rie Island Nuclear Generating Plant                                              !
l c:    Regional Administrator- Region Ill, NRC NRR Project Manager, NRC Senior Resident inspector, NRC Kris Sanda, State of Minnesota                                              ,-)
                                                                                  /
f[p Attachment
      !R    ADO K O O O 82                                                (({ llf ll(( l j\ ll ll S                  ,PDR,
                    .,                                                    '..    ..a              r . .
                                                                                                              --------J
}}
 
{{LER-Nav}}

Revision as of 00:15, 18 December 2021