==Dear Mr. Sgarro:==
==Dear Mr. Sgarro:==
By letter dated November 20,1996, the Bolling Water Reactor Owners Group (BWROG) transmitted General Electric Topical Report NEDO-32686, Revision 0, " Utility Resolution Guidance for ECCS Suction Strainer Blockage," (URG) to the staff for review. The staff has completed its review and a draft safety evaluation report (SER) has been written and is
By {{letter dated|date=November 20, 1996|text=letter dated November 20,1996}}, the Bolling Water Reactor Owners Group (BWROG) transmitted General Electric Topical Report NEDO-32686, Revision 0, " Utility Resolution Guidance for ECCS Suction Strainer Blockage," (URG) to the staff for review. The staff has completed its review and a draft safety evaluation report (SER) has been written and is
                 - attached. The staff has identified several open issues in the draft SER. The open issues cover
                 - attached. The staff has identified several open issues in the draft SER. The open issues cover
                 ? a broad spectrum of the guidance in the URG and may affect how licensees apply the guidance given in the document. Therefore, the staff believes that it is prudent to provide the BWROG with the opportunity to respond to the open l' ems before the staff publishes its final SER. It is requested that the BWROG review the draft SER and associated open items, and provide the staff with its response to the open items by March 2,1998. Following resolution of any comments received on the draft SER, the staff will issue the final SER. The final SER will
                 ? a broad spectrum of the guidance in the URG and may affect how licensees apply the guidance given in the document. Therefore, the staff believes that it is prudent to provide the BWROG with the opportunity to respond to the open l' ems before the staff publishes its final SER. It is requested that the BWROG review the draft SER and associated open items, and provide the staff with its response to the open items by March 2,1998. Following resolution of any comments received on the draft SER, the staff will issue the final SER. The final SER will

Latest revision as of 18:57, 8 December 2021

Forwards Draft SE of Topical Rept NEDO-32686,rev 0, Util Resolution Guidance for ECCS Suction Strainer Blockage, Per NRC Bulletin 96-003.Open Issues Identified in Draft Ser. Response to Open Items Requested by 980302
ML20198B740
Person / Time
Issue date: 12/31/1997
From: Berlinger C
NRC (Affiliation Not Assigned)
To: Sgarro R
PENNSYLVANIA POWER & LIGHT CO.
Shared Package
ML20198B746 List:
References
RTR-NEDO-32686 IEB-96-003, IEB-96-3, NUDOCS 9801070062
Download: ML20198B740 (1)


Text

n December 31, 1997 i

-8 / ,

Mr. Rscky Sgarro

' Pennsylvania Power and Light 2 North Ninth Street

. Mail Code A6-1 L Allentown, PA 18101

~

SUBJECT:

DRAFT SAFETY EVALUATION REPORT OF THE BOILING WATER REACTOR >

-. OWNERS GROUP'S UTILITY RESOLUTION GUIDANCE FOR ECCS SUCTION STRAINER BLOCKAGE

Dear Mr. Sgarro:

By letter dated November 20,1996, the Bolling Water Reactor Owners Group (BWROG) transmitted General Electric Topical Report NEDO-32686, Revision 0, " Utility Resolution Guidance for ECCS Suction Strainer Blockage," (URG) to the staff for review. The staff has completed its review and a draft safety evaluation report (SER) has been written and is

- attached. The staff has identified several open issues in the draft SER. The open issues cover

? a broad spectrum of the guidance in the URG and may affect how licensees apply the guidance given in the document. Therefore, the staff believes that it is prudent to provide the BWROG with the opportunity to respond to the open l' ems before the staff publishes its final SER. It is requested that the BWROG review the draft SER and associated open items, and provide the staff with its response to the open items by March 2,1998. Following resolution of any comments received on the draft SER, the staff will issue the final SER. The final SER will

- include an appendix which will provide any comments / responses received on the draft SER and the staff's resolution of those comments. The final SER should be included in the final version of the topical report.

Please feel free to call Mr. Rob Elliott at 301-415-1397 if you have any questions. The staff is also available to meet with the BWROG should you wish to discuss the resolution of the open issues in the draft SER. ,

Sincerely, Original signed by:

c Carl H. Berlinger, Chief L .

1 Containment Systems and Severe Accident Branch o'"

  • Division of Systems Safety and Analysis 9001070062 971231 Offica of Nuclear Reactor Regulation 98 '/

PDR TOPRP EMVQENE B PDR DISTRIBUTION- RLobel KKavanaugh /

Central Files . SCSB r/f (2) POR ASerkiz MMarshall MLynch DOCUMENT-NAME: A:97sgarro;1tr bl & l ro . . m w i m e cou .. nom .u.cs nv.noo. r - coo we .n.cwm.nv.neo.w. w . Nocow 0FFICE. SCSB:DSSA:NRR -l6 SCSB:DSSA G BC:SCSB: DSS /)g l l' NAME RElliott:bwfl66 JKudricl6'x CBerlinger(W DATE 12/39/97 l12/-N97 N 12/3/97 12/ /97 12/ /97 40 0FFICIAL RECORD COPY h g.f( Q #"# Ny O

_m l @lllllllhl

,y