ENS 54891: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
{{ENS notification
{{ENS notification
| event number = 54891
| event number = 54891
| facility = Mistras Group Inc.
| facility =  
| Organization = Texas Dept Of State Health Services
| Organization = Texas Dept Of State Health Services
| license number = L 06369
| license number = L 06369
| region = 4
| region = 4
| state = Texas
| state = Texas
Line 10: Line 10:
| utype =  
| utype =  
| cfr = Agreement State
| cfr = Agreement State
| emergency class = Non Emergency  
| emergency class = Non Emergency
| notification date = 09/09/2020 11:26
| notification date = 09/09/2020 11:26
| notification by = Arthur Tucker
| notification by = Arthur Tucker
Line 16: Line 16:
| event date = 09/08/2020 00:00 CDT
| event date = 09/08/2020 00:00 CDT
| last update date = 09/09/2020
| last update date = 09/09/2020
| title = Agreement State Report - Lost and Recovered Camera
| title = <Td Align="Left" Scope="Row">Agreement State Report - Lost and Recovered Camera
| event text = The following was received from Texas Department of Health Services (the agency) via email:  
| event text = The following was received from Texas Department of Health Services (the agency) via email:
On September 9, 2020, the Agency was notified by the licensee's radiation safety officer (RSO) that on September 8, 2020, one of his crews lost a QSA 880D exposure device containing a 38.1 Curie iridium-192 source. The radiography crew had placed the exposure device on the tailgate of their truck at the licensee's location. The crew drove away from the site with the exposure device still on the tailgate. The device fell off the truck a short distance from the licensee's location. A second crew left the licensee's location a short time (10 minutes) later and found the device on the pavement. The second crew performed a radiation survey of the device and found the radiation levels to be normal and the source was still fully shielded. The second crew returned the device to the licensee's location. The device was inspected and did not appear to be damaged. The licensee has sent the device to the manufacturer for inspection. Additional information has been requested from the licensee. Additional information will be provided as it is received in accordance with SA-300.  
On September 9, 2020, the Agency was notified by the licensee's radiation safety officer (RSO) that on September 8, 2020, one of his crews lost a QSA 880D exposure device containing a 38.1 Curie iridium-192 source. The radiography crew had placed the exposure device on the tailgate of their truck at the licensee's location. The crew drove away from the site with the exposure device still on the tailgate. The device fell off the truck a short distance from the licensee's location. A second crew left the licensee's location a short time (10 minutes) later and found the device on the pavement. The second crew performed a radiation survey of the device and found the radiation levels to be normal and the source was still fully shielded. The second crew returned the device to the licensee's location. The device was inspected and did not appear to be damaged. The licensee has sent the device to the manufacturer for inspection. Additional information has been requested from the licensee. Additional information will be provided as it is received in accordance with SA-300.  
Texas Incident Number: I-9798
Texas Incident Number: I-9798
THIS MATERIAL EVENT CONTAINS A "CATEGORY 2" LEVEL OF RADIOACTIVE MATERIAL
THIS MATERIAL EVENT CONTAINS A "CATEGORY 2" LEVEL OF RADIOACTIVE MATERIAL
Category 2 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for a short time (minutes to hours). It could possibly be fatal to be close to this amount of unshielded radioactive material for a period of hours to days. These sources are typically used in practices such as industrial gamma radiography, high dose rate brachytherapy and medium dose rate brachytherapy. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Category 2 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for a short time (minutes to hours). It could possibly be fatal to be close to this amount of unshielded radioactive material for a period of hours to days. These sources are typically used in practices such as industrial gamma radiography, high dose rate brachytherapy and medium dose rate brachytherapy. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2020/20200917en.html#en54891
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2020/20200918en.html#en54891
}}
}}


{{ENS-Nav}}
{{ENS-Nav}}

Latest revision as of 11:20, 15 January 2021

ENS 54891 +/-
Where
Texas Dept Of State Health Services
Deer Park, Texas (NRC Region 4)
License number: L 06369
Organization: Texas Dept Of State Health Services
Reporting
Agreement State
Time - Person (Reporting Time:+30.43 h1.268 days <br />0.181 weeks <br />0.0417 months <br />)
Opened: Arthur Tucker
11:26 Sep 9, 2020
NRC Officer: Thomas Herrity
Last Updated: Sep 9, 2020
54891 - NRC Website