05000366/LER-1982-044: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 1: Line 1:
{{Adams
#REDIRECT [[05000366/LER-1982-044, Forwards LER 82-044/03L-0]]
| number = ML20053D911
| issue date = 05/20/1982
| title = LER 82-044/03L-0:on 820428,during Refueling,Rhr Svc Water Pump 2E11-C001C Failed to Meet Rated Flow Requirements. Caused by Foreign Debris Caught in Pump.Pump Disassembled, Cleaned,Rebuilt & Successfully Retested Per HNP-2-3167
| author name = Nix R
| author affiliation = GEORGIA POWER CO.
| addressee name =
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
| docket = 05000366
| license number =
| contact person =
| document report number = LER-82-044-03L, LER-82-44-3L, NUDOCS 8206070432
| package number = ML20053D898
| document type = LICENSEE EVENT REPORT (SEE ALSO AO RO), TEXT-SAFETY REPORT
| page count = 2
}}
{{LER
| Title = 
| Plant =
| Reporting criterion =
| Power level =
| Mode =
| Docket = 05000366
| LER year = 2082
| LER number = 44
| LER revision =
| Event date =
| Report date =
| ENS =
| abstract =
}}
 
=text=
{{#Wiki_filter:NRC FORM 366                                                                                                            U. S. NUCLEAR REGULATORY COMMISSION (777) o                                                  LICENSEE EVENT REPORT CONTROL BLOCK: l i
l      l    l    l  l    lh e
(PLEASE PRINT OR TYPE ALL REQUIRED INFORMADON) 1 O i 8 9 l G l LICENSEE A l E COD l I ( l H l 2 l@l 010 l- l 0LICENSE 14    lb l0 l NUV8ER 0 l 0 l 0 l -10 l0  2b l@l4 76    l1    l1 11 LICENSE    TYPEl1JOl@l$7 CATl
                                                                                                                                                              $8 l@
COYT 10111            'ON LLj@l 015101010131616 l@l01412181812 l@l 015! 2101812 ]@
S EVENT DESCR PTION AND PROB A8                      C PSE ENCES lo 121 [0n April 28, 1982, with Unit 2 in the refuelina mode. RHR SW oumo 2 Ell- I PTTTl I C00lC failed to meet the rated flow requirements of Tech Spec 4.7.1.1.b.l
[o j j l Testing was being performed per HNP-2-3167, RHR SERVICE WATER PUMP                                                                                          l ioisjl0PERABILITY AND RATED FLOW.                                                This was not a repetitive event.                                      Public        l iO is ; [ health and sa fety was not af fected by this incident.                                                                                                      I I
10171 I l
10181 l                                                                                                                                                            80 7      8 9 C DE                  CODE        SURC E                  COMPONENT CODE                SUBC DE          SU ODE lalo]                         l W I A l@ W@ [Bj @ l P l Ul M 1 PI X l X l@ W@ [Z_j                              18          19              20 f      M                    9          10          11            12              13 SE QUENil AL                    OCCURRENCE          REPORT                    REVISION
_ EVENT YE AR                              REPOR T NO.                        CODE                TYPE                      N O.
O ,=tg g;qgg 18121
_/1          ~2
                                          /
L-J 23 1014l41 24              26 M
27 1013 l 28        TJ lL l 30
[_j 31 l0 l 32 TAKEN AC T ON              ON PL ANT              T                    HOURS        S B ITT        FOR b    B.      SUPPLt            MANUFACTURER
            ]JJ DI@l34 Zl@              [_Z_J@              LZ_j@          I 0101 0101            LLJ@            LN_j@            LA_J@        lJ  l 1 1 01547l@
35                  3b            3/                  40  41              42                43          44 CAUSE DESCRIPTION AND CORHECTIVE ACTIONS h i o      IThe cause of the pump failing to pump rated flow was due to foreion                                                                                      I i i      [ debris caught up in the pump.                                          The pump was completelv disassembled.                                          I
    , ;,      icleaned, rebuilt, and successfully retested per HNP-2-3167.                                                                                              I i a                                                                                                                                                                I l
I l i i41 1                                                                                                                                                          80 i      8 9 ST      S        % POWE R                        OTHER ST ATUS              IS O RY                          DISCOVER ( DESCRIPTION li Isl J@ l 01010l@l                                                  NA              l    lBl@lRatedFlowSurveillanceTest                                            I A TlVITY    CO TENT RELE ASE D OF RELE ASE                    AMOUNT OF ACTIVITY                                                  LOCATION OF RELE ASE 1 6      [Z_J @ [_Z_j @ l                            NA                          l        l                                    NA                                l
  /      8 9              10          11                                          44        4b                                                                  80 PERSONNEL f XPOSUHES NUYHER            TYPE          DESCRIPTION -
1i I 7 l l 01010 l@[Z_j@l                                                          NA                                                                                l
'      " ' ,, H sONN d'iN;unS                  ''                                                                                                                So N H. R            DE SCR,T,0N @                                    NA l
1 i R H 9 I 0101 Ol@l  11      12                                                                                                                              80 LOSS OF OH DAMAGE T 3 FACILITY TYPE    DE SC RIP TION A
i o      [ Zj@l                                                                                                                                                  l 1      8 9
                        ~
80 eu                                                                                                                                NRC USE ONLY 8206070432 820520                                                                                                                                  '
2 o    [ ( DR ADOCK 05000 A                                              ;    ; ; , , , ; ; , , ,;,jg
  ?      8 9          to                                                                                                            68 69                        80 5 NAVE OF PREPARER
                                                          . .        X,    Supt. of Maintenance PHONE: 912-367-7781                                                      ,
 
n e
LER #: 50-366/1982-44 Licensee: Georgia Power Company Facility Name: Edwin I. Hatch Docket #: 50-366 Narrative Report For LER 50-366/1982-44 On April 28, 1982, with Unit 2 in refueling mode, RHR SW pump 2 Ell-C001C attained a flow of 2750 gpm at 390 psig. This flow rate fails to meet the rated flow requirement of Tech Spec 4.7.1.1.b (i.e. , 300 psig at 4000 gpm). Normal surveil-lance was being performed per HNP-2-3167, RHR SERVICE WATER PUMP OPERABILITY AND RATED FLOW. This was not a repetitive occurrence. Public health and safety was not affected by this incident.
When the pump was disassembled per Maintenance Request 2-82-2290(dated 4-28-82),
foreign debris were found lodged in the pump flow path. The pump was completely disassembled, cleaned, rebuilt, and reinstalled.      HNP-2-3167 was then performed on 5-12-82 with satisfact( ry results.
ll
'l L
i
}}
 
{{LER-Nav}}

Latest revision as of 03:29, 19 March 2020