05000237/LER-1982-013: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
{{Adams
#REDIRECT [[05000237/LER-1982-013, Forwards LER 82-013/03X-1]]
| number = ML20054G470
| issue date = 06/04/1982
| title = LER 82-013/03X-1:on 820402,LPCI Differential Pressure Switch 2-261-35B Failed to Operate on Increasing Pressure.Caused by Wear of Contact Point in Mechanical Linkage Operating Switch.Internal Zero Screw Adjusted
| author name = Schroeder B
| author affiliation = COMMONWEALTH EDISON CO.
| addressee name =
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
| docket = 05000237
| license number =
| contact person =
| document report number = LER-82-013-03X-01, LER-82-13-3X-1, NUDOCS 8206210587
| package number = ML20054G459
| document type = LICENSEE EVENT REPORT (SEE ALSO AO,RO), TEXT-SAFETY REPORT
| page count = 2
}}
{{LER
| Title = 
| Plant =
| Reporting criterion =
| Power level =
| Mode =
| Docket = 05000237
| LER year = 2082
| LER number = 13
| LER revision =
| Event date =
| Report date =
| ENS =
| abstract =
}}
 
=text=
{{#Wiki_filter:~
LICENSEE EVENT REPORT
[ CONTZOL BLOCK: ll
            ,                          i l      l    l  l lh (PLEASE PMINTCQ TYPE ALL REZul%EJ INFZCMAT1!N)
  ] l4 Il3 Ll Dl          a l S l 2 l@l ol ol -l o l oUCENSE UcENSEE COct              i4      15 l o l o I -l ol o2h gl 284 l 1uCENSE l o NUMsER                                          l1 l1 l 1 l@l l l@
TYPE Jo    57 GAT S4 9T
  @8            $y","c      lL @l0j5lolol0l2l3l7 gl0l4l0 l2 l8 l 2 @l016 l0 l4 l8 l2l@
60          $1            cocKET NUMSER                68    69      EVENT cATg            74      75        REPORT oATE        80 EVENT DEScalFTION AND PROSA8LE CONSEQUENCES g[ While performing monthly surveillance IS 1500-9, it was found that LPCI Differential                                                                                      l Pressure Switch 2-261-35B failed to operate on increasing differential pressure (T.S.                                                                          l 3.2.8) . The safety implications were minimal because the remaining three switches were                                                                        l all operative and would have performed as designed. There was no effect on public                                                                              y health or safety. do previous occurrences noted.                                                                                                                    '
I
@l                                                                                                                                                                            I l
a    i                                                                                                                                                                    I ao                                                                                                                                                                  ao So7E            ton          su$cEE                  cOMPoNENr Coot                  Sus "c'o'E          $U l 8 l Il B l@ l El@ l B l@ l 11 Ni si Tl a l u l@ l Sl@ W h s        to          11            12            13                            is          is                20 EV ENT YEAR                            R      No.                              o                    .d                        N .
cg
        @ ,"ggpjgg a
                              ,_  l21 Cl22 21 l_l 23 l 0 l1 l3 l 24            28 l-l 27 lo l3 l 28      :s lxl 30 l_l 31 11 l N AC o                  oP      T          M TH                    MouRS 22          58              PoR      8.      SUP UE              MA UF  RER gg IEl@lZl@ l Zl@
33          34                35 l36Z I@        l of ol 0; 37                    40 l    l Nig lY Jg el            42                  43 l c i o l8 lo jg 44            47 CAUSE DESCRIPTION AND CCARECTIVE ACTIONS h g l The cause was believed to be wear of a contact point in the mechanical linkane which                                                                                      I l
g ; operates the switch. Switch movement is less than 1/64 inch between open and closed.                                                                                      I
        ;  Af ter minor adjustment of internal "zero" screw, the switch operated. The pressura                                                                              ;
        ;    switch was then adjusted to 55 I 5 inch dp increasing and repeatability was verified.                                                                            [
DIS 1500-9 will continue to be performed. No further action deened necessary.                                                                                  ;
6 s s                                                                                                                                                                so ST                    % POWER                      oTHER STATUS              ol O      Y                        otscoVERY oESCRIPT1oN
{ l El@ l o l 9 l8 lhlo                                    N/A l    l* B lhl*            Surveillance Tests                                          l l ' Jn,,,,          cd:TENr
                                          '2                                                                                                                            a l    <Et                                                                                                                  tocanoN o,REtu E @
] l ost@o    Zl      o,l REtusEZlglN/A          iucuNTo, cnviry @ l                          l                N/A l
              , mon ~Et ExPosSEs NuusER                TveE B i* lo 10 'l@lZl@l                          oEscaimoN @ N/A                                                                                                              l l*
l P = SONNE' tin;URits
                                              '3                                                                                                                        so NuMsER                oEseniPrioN@
b I Ol 0l 0l@l            is      12 N/A so l
l 4 s I      toss op oR cAuacE To PActury TWE          cESCRIPTioN
{ l Zl@l                                                    N/A 80 f ' *isausu$Tv                                                8206210587 820514                                                                      NRC USE CNLY              ,
hDRADOCK 05000237 b' 'lsutoNlhlcEscaimoN@
N/A                                            ppg                                        ;
sa se
                                                                                                                                                ; ; ;;;9;;;,          , g9 so.i l
B. A. Schroeder NAME OF PREPARER                                                                                  PHONE:
2 I
                                                                                          ;. _                                                                                      .j
 
F-J SUPPLEMENT TO DVR                                        -
l                                                DVR NO.                                                        .
STA      UtilT.      YEAR      NO.
D-      12  -    2  -    82  -    24 PART I l TITLE OF EVENT                                                  OCCURRED
                                                                                                  -~
LPCI Loop Select dPIS 2-261-3SB Failure DATE        TIME REASON FOR SUPPLEMENTAL REPORT
;                  Revised cause subcode to "B" and corrected LER sequential report number from 82-42 t6 82-13.
1
!              PART 2 l ACCEPTANCE BY STATION REVIEW                  h.b_r-a->' / d..
OATE h\1\1b 'd/4/ru
'                                                                    j'            ;
                                                                                      ' /
SUPPLEMENTAL REPORT APPROVED AND AUTHORIZED FOR 3ISTRIBUTION
                                                                      .f
[v j'f-                        //
STATI f /v/f4_
SUyRINTENDENT              / DATE i                                                              ,
I                                                                                                                      .-
i' I
t
                                      . - _ . _ .      ..
}}
 
{{LER-Nav}}