ML20055C036: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 1: Line 1:
{{Adams
#REDIRECT [[05000317/LER-1982-032]]
| number = ML20055C036
| issue date = 07/29/1982
| title = LER 82-032/03L-0:on 820629,motor Operated Isolation Valve in Salt Water Sys Supply to Circulating Water Pump Room Air Coolers Inoperable Electrically & Would Not Respond Properly to Sias.Caused by Tripped Thermal Overloads
| author name = Basso L, Pavis G
| author affiliation = BALTIMORE GAS & ELECTRIC CO.
| addressee name =
| addressee affiliation = NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
| docket = 05000317
| license number =
| contact person =
| document report number = LER-82-032-03L, LER-82-32-3L, NUDOCS 8208100057
| package number = ML20055C016
| document type = LICENSEE EVENT REPORT (SEE ALSO AO,RO), TEXT-SAFETY REPORT
| page count = 1
}}
 
=Text=
{{#Wiki_filter:NRC FORM 366                                                                                                            U.S. NUCLEAR REGULATORY COMMISSION (7 77).    ,
LICENSEE EVENT REPORT CONTROL BLOCCO l t
l  l    l    l  l e
lh                    (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) lo l t8l 9l Ml Dl 7
Cl Cl Nl 1 14l@ltb0 l 0 l - l 0 l LICENSE LICENSEE CODE 0 l 0 NUMBEH l 0 ! 0 l - l 0 l 0 25l@l264 l 1LICENSE  l 1 l 1TYPE l 1Jol@l$7    l LAI b6 l@
CON'T 101il              [$ l Ll@l          0l 615 l O l 0DOCKET l ONUMBE l 3 lR 1 l 7 @l            069 l 6 lEVENT 2 l DATE 9 l 8 l 2 l@l 0 l 7REPORT          l 2 lDATE 9 l 8 l 802 lh 7      5                      60                                                    68                                  74      75 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h O 2 l                While in Mode 3 at 0920. a motor operated isolation valve (1-MOV-5251)                                                                          l 10131 l                  in the salt water system supply to the circulating water pump room air                                                                          l 1014 I I                coolers would not operate electrically and therefore would not have                                                                            l lo Isl I                responded properly to an SIAS (T.S. 3.7.5.1).                                        Investigation determined                                  l l O 16 l l              that the motor overloads were tripped. The overloads were immediately                                                                          1    -
l O lJJ l                reset and the valve tested satisfactorily at 1025. The redundant MOV                                                                            l 10IRl [                 was shut during this event. Similar event:                                        50-318/81-09.                                                l 7      8 9                                                                                                                                                          80 C E              CODE      SUBCO E                    COMPONENT CODE                SUBCODE          SU    E lOl91 7      8 l Wl Bl@ W@ W@ lV l A lL lV l0 lP l@ {@ W @
9        10        11          12                13                          18          19              20
_                                      SEQUE N TI AL                      OCCUR R ENCE        REPORT                    REVIS80N LE R HO    EVENT YE AR                          REPORT NO.                              CODE              TYPE                        N O.
O"sgg l18l2l a
2J l-l 23 1013121 74              26 Ld 27 10 13 i 28      TJ LLJ 30 l-]
31 lo_J 32
_2 K      ACT ON            ON PL T            T                  ' HOURS            SB IT D        FOR        B.      SUPPLIE          MANUFACTURER W@W@ W@ lZl@                                                  l0 l0 !0 l0 l                W@ W@                              l43A l@      lL    l2 l0 l0 47l@
JJ            34                35              M            3/                      40  41              42                              44 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h 11 I O I I              Thermal overloads on Phases A and C were found trinned. These were reset                                                                          I i i      l          and the valve onerated satisfactorily.                                      Investination into the cause is                                      I lil2l l                  continuinn. Cearbox lubrication will be checked and the overload devices                                                                          1
[ilal l                  will be functionally tested. The motor and breaker are tested annually.                                                                          l li l41 l                                                                                                                                                              80 l
7      8 9                                                                                                                                                                      i ST        S          % POWE R                  OTHER STATUS                O SCO RY                            DISCOVERY DESCRIPTION W lC lh l0l0l0l@I                                        N/A                        l      lAl@l          Operator Observation                                        l ACTIVITY CONTENT AMOUNT OF ACTIVITY                                                    LOCATION OF RELEASE LLl ASE@D                                                                                    N/A 7
i c RELE 8 9                  10          11 OFN/A  RELE ASELzJ@l            44 l          l 45                                                                  80 l
PE RSONNEL E XPOSURES NUM6ER            TYPE        DESCRIPTION 39 li 171        l0 l0 l0 l@W@l                                  NA                                                                                                        l PERSONNE L INJURIES NUMBER            DESCRIPi!ON M l0l0l0l@l 7      8 9                  11      12 N/A 80 l
LTYPE OSS OF OR DAMAGE TO FACILITY Q DE SCRIPTION                v 1 9 W @l                          N/A                                                                                                                            l PUBLIETY                                  8100057 820729                                                                          NRC USE ONLY ADOCK 05000317                                                                                                %
2 o    ISSUE
[jtj          l D@ DESCRIPTIONN/A                                          PDR                                              l    lIllIlIlllIIIi 7      8 9              10                                                                                                            68 69                        80 S NAME OF PREPARER G. S. a s        .      .      asso                          PHONE:}}