ML18045A742: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
Line 6: | Line 6: | ||
| number = ML18045A743 | | number = ML18045A743 | ||
| issue date = 09/30/1980 | | issue date = 09/30/1980 | ||
| title = | | title = LER 80-035/03L-0:on 800830,during Return to Svc After Shutdown,Leakage Discovered Through Pressure Relief Valve. Caused by Loose Spring Guide within Solenoid Assembly Valve Due to Failed Brazed Joint.Guide Brazed Back Onto Plate | ||
| author name = Withrow G | | author name = Withrow G | ||
| author affiliation = CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.), | | author affiliation = CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.), |
Latest revision as of 02:07, 6 March 2020
Date released: 10/31/2018 | Download: ML18045A742 |
---|---|
ML18045A743 | |
Person / Time | |
---|---|
Site: | Palisades |
Issue date: | 09/30/1980 |
From: | Withrow G CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |
Download: ML18045A743 (1) | |
ML18045A741 | |
Person / Time | |
---|---|
Site: | Palisades |
Issue date: | 09/30/1980 |
From: | Withrow G CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
To: | KEPPLER J G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |
Download: ML18045A741 (1) | |