| number = ML18139A134 | | number = ML18139A134 | ||
| issue date = 04/02/1980 | | issue date = 04/02/1980 | ||
| title = | | title = LER 80-014/01T-0:on 800320,informed by Westinghouse That Incident of Stress Corrosion Cracking in Control Rod Support Pins & Flexures Noted in Foreign Plant.Vendor Testing & Assessment Program in Progress.Appropriate Action Planned | ||
| author name = | | author name = Wilson J | ||
| author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) | | author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) | ||
| addressee name = | | addressee name = | ||
Line 21: | Line 21: | ||
| number = ML18139A133 | | number = ML18139A133 | ||
| issue date = 04/02/1980 | | issue date = 04/02/1980 | ||
| title = | | title = LER 80-002/01T-0:on 800320,insp of Containment Following Type a Leak Rate Revealed Eight 1/4 Inch Holders Drilled Through Containment Liner.Caused by Improper Interpretation of Procedure During Design Change 78-48.Repair Planned | ||
| author name = | | author name = Wilson J | ||
| author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) | | author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) | ||
| addressee name = | | addressee name = | ||
Line 37: | Line 37: | ||
| issue date = 04/02/1980 | | issue date = 04/02/1980 | ||
| title = Forwards LERs 80-014/01T-0 & 80-002/01T-0 | | title = Forwards LERs 80-014/01T-0 & 80-002/01T-0 | ||
| author name = | | author name = Wilson J | ||
| author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) | | author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) | ||
| addressee name = OREILLY J P | | addressee name = OREILLY J P |
Latest revision as of 12:30, 25 January 2020
Date released: 12/10/2018 | Download: ML18139A132 |
---|---|
ML18139A134 | |
Person / Time | |
---|---|
Site: | Surry |
Issue date: | 04/02/1980 |
From: | Joshua Wilson VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML18139A134 (2) | |
ML18139A133 | |
Person / Time | |
---|---|
Site: | Surry |
Issue date: | 04/02/1980 |
From: | Joshua Wilson VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML18139A133 (2) | |
ML18139A131 | |
Person / Time | |
---|---|
Site: | Surry |
Issue date: | 04/02/1980 |
From: | Joshua Wilson VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) |
To: | OREILLY J P NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |