ML19209C889: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 6: | Line 6: | ||
| number = ML19209C899 | | number = ML19209C899 | ||
| issue date = 10/11/1979 | | issue date = 10/11/1979 | ||
| title = | | title = Final Deficiency Rept Re Invalid Heat Treatment of Reactor Pressure Vessel Pedestal Studs.Studs Fabricated by Acimet Mfg Co in Lots Exceeding ASME Requirements.Caused by Error on Purchase Order in Specs for Heat Treated Matl | ||
| author name = | | author name = | ||
| author affiliation = TENNESSEE VALLEY AUTHORITY | | author affiliation = TENNESSEE VALLEY AUTHORITY |
Latest revision as of 07:09, 24 January 2020
Date released: 08/11/2019 | Download: ML19209C889 |
---|---|
ML19209C899 | |
Person / Time | |
---|---|
Site: | Hartsville |
Issue date: | 10/11/1979 |
From: | TENNESSEE VALLEY AUTHORITY |
To: | |
References | |
Download: ML19209C899 (2) | |
ML19209C888 | |
Person / Time | |
---|---|
Site: | Hartsville |
Issue date: | 10/11/1979 |
From: | Mills L TENNESSEE VALLEY AUTHORITY |
To: | OREILLY J P NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |
Download: ML19209C888 (1) | |