ML19263A837: Difference between revisions

From kanterella
Jump to navigation Jump to search
Created page by program invented by StriderTol
 
Created page by program invented by StriderTol
 
Line 6: Line 6:
| number = ML19267A269
| number = ML19267A269
| issue date = 12/29/1978
| issue date = 12/29/1978
| title = Forwards LER 78-037/03L-0
| title = LER 78-037/03L-0 on 781201:during Valve Maintenance Check, Valve 1-71-580 in Reactor Core Isolation Cooling Sys Found in Open Position.Caused by Pin Shearing on Valve Disk
| author name =  
| author name =  
| author affiliation = TENNESSEE VALLEY AUTHORITY
| author affiliation = TENNESSEE VALLEY AUTHORITY

Latest revision as of 10:32, 23 January 2020

Forwards LER 78-037/03L-0
Date released: 10/08/2019 Download: ML19263A837


LER 78-037/03L-0 on 781201:during Valve Maintenance Check, Valve 1-71-580 in Reactor Core Isolation Cooling Sys Found in Open Position.Caused by Pin Shearing on Valve Disk
ML19267A269
Person / Time
Site: Browns Ferry 
Issue date: 12/29/1978
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19267A269 (2)
Forwards LER 78-037/03L-0
ML19267A265
Person / Time
Site: Browns Ferry 
Issue date: 12/29/1978
From: Fox H
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19267A265 (1)