ML19270G108: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 6: Line 6:
| number = ML19270G111
| number = ML19270G111
| issue date = 04/17/1978
| issue date = 04/17/1978
| title = Forwards LER 78-022/01T-0
| title = LER 78-022/01T-0 on 780404:Fischer & Porter 10B2496 Transmitters for Coolant Low Flow Monitoring Had High Output Deviation During Seismic Test.Caused by Vibration of Mounting Plate.Design Change Initiated
| author name = Spencer T
| author name = Spencer T
| author affiliation = PUBLIC SERVICE ELECTRIC & GAS CO. OF NEW JERSEY
| author affiliation = PUBLIC SERVICE ELECTRIC & GAS CO. OF NEW JERSEY

Latest revision as of 09:06, 23 January 2020

Forwards LER 78-022/01T-0
Date released: 10/11/2019 Download: ML19270G108


LER 78-022/01T-0 on 780404:Fischer & Porter 10B2496 Transmitters for Coolant Low Flow Monitoring Had High Output Deviation During Seismic Test.Caused by Vibration of Mounting Plate.Design Change Initiated
ML19270G111
Person / Time
Site: Salem PSEG icon.png
Issue date: 04/17/1978
From: Spencer T
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19270G111 (3)
Forwards LER 78-022/01T-0
ML19270G107
Person / Time
Site: Salem PSEG icon.png
Issue date: 04/17/1978
From: Librizzi F
Public Service Enterprise Group
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19270G107 (1)