| number = ML19345G524 | | number = ML19345G524 | ||
| issue date = 03/31/1981 | | issue date = 03/31/1981 | ||
| title = | | title = LER 80-034/03X-1:on 800411,auxiliary Feed Pump Turbine 1 Steam Inlet Pressure Switch PSL-106B Actuated at Pressure Above Desired Setpoint.Caused by Failure of Static O-ring Pressure Switch Model 6V2-E2-T1X4.Switch Replaced | ||
| author name = Trautman D | | author name = Trautman D | ||
| author affiliation = TOLEDO EDISON CO. | | author affiliation = TOLEDO EDISON CO. |
Latest revision as of 00:20, 17 January 2020
Date released: 12/25/2019 | Download: ML19345G522 |
---|---|
ML19345G524 | |
Person / Time | |
---|---|
Site: | Davis Besse |
Issue date: | 03/31/1981 |
From: | Trautman D TOLEDO EDISON CO. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |
Download: ML19345G524 (2) | |
ML19345G521 | |
Person / Time | |
---|---|
Site: | Davis Besse |
Issue date: | 03/30/1981 |
From: | Murray T TOLEDO EDISON CO. |
To: | KEPPLER J G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
References | |
Download: ML19345G521 (1) | |