ML19347A938: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 6: Line 6:
| number = ML19347A943
| number = ML19347A943
| issue date = 09/25/1980
| issue date = 09/25/1980
| title = Forwards Updated LER 80-025/01T-1
| title = Updated LER 80-025/01T-1:on 800904,ultrasonic Examination of Steam Generator Support Bolts Revealed That Most Had Crack Indications.Preliminary Cause Suggests Environmentally Assisted Cracking
| author name = Hunstad A
| author name = Hunstad A
| author affiliation = NORTHERN STATES POWER CO.
| author affiliation = NORTHERN STATES POWER CO.

Latest revision as of 00:23, 17 January 2020

Forwards Updated LER 80-025/01T-1
Date released: 12/27/2019 Download: ML19347A938


Updated LER 80-025/01T-1:on 800904,ultrasonic Examination of Steam Generator Support Bolts Revealed That Most Had Crack Indications.Preliminary Cause Suggests Environmentally Assisted Cracking
ML19347A943
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 09/25/1980
From: Hunstad A
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19347A943 (1)
Forwards Updated LER 80-025/01T-1
ML19347A937
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 09/25/1980
From: Mayer L
NORTHERN STATES POWER CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19347A937 (1)