{{#Wiki_filter:Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 September 25, 2012 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296  
{{#Wiki_filter:Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 September 25, 2012 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296


==Subject:==
==Subject:==
Generic Letter 96-05 Class "D" Joint Owners' Group Motor Operated Valves  
Generic Letter 96-05 Class "D" Joint Owners' Group Motor Operated Valves


==Reference:==
==Reference:==
Regulatory Issue Summary (RIS) 2011-13, "Follow Up to Generic Letter 96-05 for Evaluation of Class "D" Valves Under Joint Owners Group Motor-Operated Valve Periodic Verification Program," issued January 6, 2012 The Tennessee Valley Authority (TVA) has identified a small number of Joint Owners Group (JOG) Class "D" Motor-Operated Valves (MOVs) installed at Browns Ferry Nuclear Plant (BFN),
Units 1, 2, and 3, that will not have the required modifications completed by September 25, 2012, to allow their classification as Class "A" or Class "B" JOG valves.
The TVA is continuing to review the valves included in the BFN JOG MOV program and will provide the NRC with updated information by December 14, 2012, a date corresponding to 19 days after the scheduled completion of the BFN Unit 1 outage. This supplemental information will include identification of BFN Class "D" MOVs with a corresponding implementation schedule for completion of modifications to allow classification of the identified Class "D" MOVs as Class "A" or Class "B."
The Enclosure contains the regulatory commitment associated with this submittal. If you have any questions on this information, please contact Kara Stacy at (423) 751-3489.
Respectfully, J. W. Shea Vice President, Nuclear Licensing 4Ao13 Printed on recycled paper


Regulatory Issue Summary (RIS) 2011-13, "Follow Up to Generic Letter 96-05 for Evaluation of Class "D" Valves Under Joint Owners Group Motor-Operated Valve Periodic Verification Program," issued January 6, 2012 The Tennessee Valley Authority (TVA) has identified a small number of Joint Owners Group (JOG) Class "D" Motor-Operated Valves (MOVs) installed at Browns Ferry Nuclear Plant (BFN), Units 1, 2, and 3, that will not have the required modifications completed by September 25, 2012, to allow their classification as Class "A" or Class "B" JOG valves.The TVA is continuing to review the valves included in the BFN JOG MOV program and will provide the NRC with updated information by December 14, 2012, a date corresponding to 19 days after the scheduled completion of the BFN Unit 1 outage. This supplemental information will include identification of BFN Class "D" MOVs with a corresponding implementation schedule for completion of modifications to allow classification of the identified Class "D" MOVs as Class"A" or Class "B." The Enclosure contains the regulatory commitment associated with this submittal.
U.S. Nuclear Regulatory Commission Page 2 September 25, 2012
If you have any questions on this information, please contact Kara Stacy at (423) 751-3489.Respectfully, J. W. Shea Vice President, Nuclear Licensing 4Ao13 Printed on recycled paper U.S. Nuclear Regulatory Commission Page 2 September 25, 2012  


==Enclosure:==
==Enclosure:==


Regulatory Issue Summary 2011-13 -Regulatory Commitment cc (Enclosure):
Regulatory Issue Summary 2011 Regulatory Commitment cc (Enclosure):
NRC Regional Administrator  
NRC Regional Administrator - Region II NRC Senior Resident Inspector - Browns Ferry Nuclear Plant
-Region II NRC Senior Resident Inspector  
 
-Browns Ferry Nuclear Plant ENCLOSURE Browns Ferry Nuclear Plant Units 1, 2 and 3 Regulatory Issue Summary 2011-13 -Regulatory Commitment See attached E-1 REGULATORY COMMITMENT COMMITMENT COMPLETION DATE The Tennessee Valley Authority will provide the NRC with the following information:
ENCLOSURE Browns Ferry Nuclear Plant Units 1, 2 and 3 Regulatory Issue Summary 2011 Regulatory Commitment See attached E-1
* Population of Browns Ferry Nuclear Plant identified Class "D" Motor-Operated Valves December 14, 2012" Corresponding implementation schedule for completion of modifications to allow classification of the identified Class "D" Motor-Operated Valves as Class "A" or Class"B" E-2}}
 
REGULATORY COMMITMENT COMMITMENT                               COMPLETION DATE The Tennessee Valley Authority will provide the NRC with the following information:
* Population of Browns Ferry Nuclear Plant identified Class "D"Motor-Operated Valves                             December 14, 2012
    " Corresponding implementation schedule for completion of modifications to allow classification of the identified Class "D" Motor-Operated Valves as Class "A" or Class "B"
E-2}}

Revision as of 22:00, 11 November 2019

Generic Letter 96-05 Class D Joint Owners' Group Motor Operated Valves Install
ML12272A119
Person / Time
Site: Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 09/25/2012
From: James Shea
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML12272A119 (4)


Text

Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 September 25, 2012 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296

Subject:

Generic Letter 96-05 Class "D" Joint Owners' Group Motor Operated Valves

Reference:

Regulatory Issue Summary (RIS) 2011-13, "Follow Up to Generic Letter 96-05 for Evaluation of Class "D" Valves Under Joint Owners Group Motor-Operated Valve Periodic Verification Program," issued January 6, 2012 The Tennessee Valley Authority (TVA) has identified a small number of Joint Owners Group (JOG) Class "D" Motor-Operated Valves (MOVs) installed at Browns Ferry Nuclear Plant (BFN),

Units 1, 2, and 3, that will not have the required modifications completed by September 25, 2012, to allow their classification as Class "A" or Class "B" JOG valves.

The TVA is continuing to review the valves included in the BFN JOG MOV program and will provide the NRC with updated information by December 14, 2012, a date corresponding to 19 days after the scheduled completion of the BFN Unit 1 outage. This supplemental information will include identification of BFN Class "D" MOVs with a corresponding implementation schedule for completion of modifications to allow classification of the identified Class "D" MOVs as Class "A" or Class "B."

The Enclosure contains the regulatory commitment associated with this submittal. If you have any questions on this information, please contact Kara Stacy at (423) 751-3489.

Respectfully, J. W. Shea Vice President, Nuclear Licensing 4Ao13 Printed on recycled paper

U.S. Nuclear Regulatory Commission Page 2 September 25, 2012

Enclosure:

Regulatory Issue Summary 2011 Regulatory Commitment cc (Enclosure):

NRC Regional Administrator - Region II NRC Senior Resident Inspector - Browns Ferry Nuclear Plant

ENCLOSURE Browns Ferry Nuclear Plant Units 1, 2 and 3 Regulatory Issue Summary 2011 Regulatory Commitment See attached E-1

REGULATORY COMMITMENT COMMITMENT COMPLETION DATE The Tennessee Valley Authority will provide the NRC with the following information:

  • Population of Browns Ferry Nuclear Plant identified Class "D"Motor-Operated Valves December 14, 2012

" Corresponding implementation schedule for completion of modifications to allow classification of the identified Class "D" Motor-Operated Valves as Class "A" or Class "B"

E-2