ML18054A204: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 16: | Line 16: | ||
=Text= | =Text= | ||
{{#Wiki_filter:From: Diaz-Sanabria, Yoira | {{#Wiki_filter:From: Diaz-Sanabria, Yoira Sent: Thursday, February 15, 2018 2:38 PM To: 'donnagilmore@gmail.com' <donnagilmore@gmail.com> | ||
> | |||
==Subject:== | ==Subject:== | ||
FW: ACTION DUE 12/5 Re: Response to Question Holtec UMAX San Onofre dry storage system Donna, I am the supervisor in charge of the thermal reviews for the Division of Spent Fuel Management (DSFM) in the Office of Nuclear Material Safety and Safeguards at the Nuclear Regulatory Commission. My understanding is that you had | FW: ACTION DUE 12/5 Re: Response to Question Holtec UMAX San Onofre dry storage system | ||
: Donna, I am the supervisor in charge of the thermal reviews for the Division of Spent Fuel Management (DSFM) in the Office of Nuclear Material Safety and Safeguards at the Nuclear Regulatory Commission. My understanding is that you had email exchanges with DSFM Director, Michael Layton, regarding the UMAX storage system. In one of the emails you had several questions specifically about the thermal analyses. Please see attached the responses to your questions. | |||
Feel free to contact us if you need any additional information. | |||
Yoira Diaz Sanabria}} | Yoira Diaz Sanabria}} |
Revision as of 20:07, 21 October 2019
ML18054A204 | |
Person / Time | |
---|---|
Issue date: | 02/15/2018 |
From: | Yoira Diaz-Sanabria NRC/NMSS/DSFM/CSTB |
To: | Gilmore D - No Known Affiliation |
Diaz-Sanabria Y | |
Shared Package | |
ML18054A201 | List: |
References | |
Download: ML18054A204 (1) | |
Text
From: Diaz-Sanabria, Yoira Sent: Thursday, February 15, 2018 2:38 PM To: 'donnagilmore@gmail.com' <donnagilmore@gmail.com>
Subject:
FW: ACTION DUE 12/5 Re: Response to Question Holtec UMAX San Onofre dry storage system
- Donna, I am the supervisor in charge of the thermal reviews for the Division of Spent Fuel Management (DSFM) in the Office of Nuclear Material Safety and Safeguards at the Nuclear Regulatory Commission. My understanding is that you had email exchanges with DSFM Director, Michael Layton, regarding the UMAX storage system. In one of the emails you had several questions specifically about the thermal analyses. Please see attached the responses to your questions.
Feel free to contact us if you need any additional information.
Yoira Diaz Sanabria