ML060240260: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
Line 1: Line 1:
{{Adams
#REDIRECT [[RNP-RA/06-0001, Submittal of 90 Day Inservice Inspection Summary Report]]
| number = ML060240260
| issue date = 01/16/2006
| title = Submittal of 90 Day Inservice Inspection Summary Report
| author name = Baucom C T
| author affiliation = Progress Energy Co
| addressee name =
| addressee affiliation = NRC/Document Control Desk, NRC/NRR
| docket = 05000261
| license number = DPR-023
| contact person =
| case reference number = RNP-RA/06-0001
| document type = Inservice/Preservice Inspection and Test Report, Letter
| page count = 136
}}
 
=Text=
{{#Wiki_filter:a0 Progress Energy 10 CFR 50.55a Serial: RNP-RA/06-0001 JAN 1 6 2006 United States Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50-261/LICENSE NO. DPR-23 SUBMITTAL OF 90 DAY INSERVICE INSPECTION
 
==SUMMARY==
REPORT Ladies and Gentlemen:
In accordance with the requirements of 10 CFR 50.55a, "Codes and Standards," Carolina Power and Light Company, also known as Progress Energy Carolinas, Inc., is providing, as an attachment to this letter, the Inservice Inspection Summary Report for Class 1 and Class 2 pressure retaining components and their supports.
This report has been prepared in accordance with the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section XI, 1995 Edition, 1996 Addenda, Article IWA-6000.
This report covers inspection activities before and during Refueling Outage 23 at the H. B. Robinson Steam Electric Plant, Unit No. 2.If you have any questions concerning this matter, please contact me at (843) 857-1253.Sincerely, 6&2ly C. T. Baucom Supervisor
-Licensing/Regulatory Programs CTB/cac Attachment c: Resident Inspector, HBRSEP C. P. Patel, NRC, NRR W. D. Travers, NRC, Region II Progress Energy Carolinas, Inc.Robinson Nuclear Plant 3581 West Entrance Road Hartsville, SC 29550 fV Ocl7 MENNNmr-United States Nuclear Regulatory Commission Attachment to Serial: RNP-RA/06-0001 H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 INSERVICE INSPECTION
 
==SUMMARY==
REPORT FOR REFUELING OUTAGE 23 INSERVICE INSPECTION REPORT INTERVAL 4, PERIOD 2, OUTAGE 1 (RO #23)ISI
 
==SUMMARY==
REPORT FOR H.B. ROBINSON NUCLEAR STATION (UNIT 2)3581 WEST ENTRANCE ROAD HARTSVILLE, SC 29550 CAROLINA POWER AND LIGHT, Dba, PROGRESS ENERGY CAROLINAS, INC.411 FAYETTEVILLE STREET RALEIGH, NC 27602 COMMERCIAL SERVICE DATE: 3/7/71 REPORT COMPLETION DATE: 12/12/05'I of 43 1995 Edition 1996 Addenda APPENDIX II -MANDATORY FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules FORM NIS-1 1. Owner: CP&L. Inc. Dba Progress Energy Carolinas, Inc.. 411 Fayetteville St.. Raleigh, NC 27602 (Name and Address of Owner)2. Plant: H.B. Robinson, 3581 West Entrance Rd., Hartsville.
SC 29550 (Name and Address of Plant)3. Plant Unit: 2 4. Owner Certificate of Authorization (if required)
N/A 5. Commercial Service Date: 3/7/1971 6. National Board Number for Unit: 20772 7. Components Inspected Manufacturer Component or Manufacturer or or Installer State or National Appurtenance Installer Serial No. Province No. Board No.Steam Generator B Westinghouse S/N 93733 N/A N/A Reactor Coolant Pump B Westinghouse CPLRCPCPC2 N/A N/A Piping Ebasco Services N/A N/A N/A Piping Maintenance N/A N/A N/A 2 of 43 Form NIS-1 SECTION Xl -DIVISION 1 1995 Edition, thru 1996 Addenda FORM NIS-1 (Back)8. Examination Dates: 5/30/2004 to 10/27/2005
: 9. Inspection Period Identification:
Period 2 (2/19/2005/2/19/2009)
: 10. Inspection Interval from: 2/19/2002 to 2/19/2012 11. Applicable Editions of Section Xl: 1995 Edition. thru 1996 Addenda 12. Date / Revision of the Inspection Plan: 4/28/2005 Revision 7 13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan.See Attached Summaries 12. Abstract of Results of Examination and Tests.See Attached Summaries 13. Abstract of Corrective Measures.See attached Summaries We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section Xl, and c) corrective measures taken conform to the rules of the ASME Code, Section Xi.Certificate of Authorization No. (if applicable):
N/A Expiration Date: N/A Date: 12/8/2005 Signed: ProEress Energy Carolinas, Inc. By: Jar, e Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT have inspected the components described in this Owner's Report during the period 5/30/2004 to 12/7/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certification neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property da or a loss of any kind arising from or connected with this inspection.
Commissions NC 1507 Inspector's Signature National Board, State, Province, and Endorsement Date: Dc br?005 3 of 43
 
===1.0 ABSTRACT===
1.1 This report presents the results of the Inservice Inspection of the Fourth Interval, Second Period, First Outage, for refueling outage number twenty-three (RFO#23), at the H. B. Robinson Unit 2 Nuclear Station. Examinations of steam generator feedwater nozzles per NRC IE Bulletin No. 79-13, piping welds, piping supports, component welds, component supports, and bolting and were conducted in accordance with ASME Section Xl, 1995 Edition, thru 1996 Addenda. Repair and replacement efforts included modification and maintenance of component replacements.
Pressure testing of ASME Code systems and their components was performed in accordance with the requirements of ASME Section Xl, IWA-5000, IWB-5000, IWC-5000, and IWD-5000. No service-induced flaws, which exceeded the acceptance criteria of ASME Section Xl, were detected during the inservice examinations of pressure retaining components.
Indications discovered during visual examination of component supports were evaluated and accepted, repaired or restored to the original design configurations.
 
==2.0 INTRODUCTION==
 
2.1 This report contains a detailed iteem-by-item summary of examinations and results performed by Progress Energy Carolinas, Inc. and iTi, integrated Technologies, inc., since the start of RFO-23, on 9/17/2005.
The Fourth Interval, Second Period examination percentage requirements are contained in Tab G.Examination reports, sketches, examination limitations, consumable testing materials, personnel qualifications and calibration standards are retained by Progress Energy Carolinas, Inc.. on site. Detailed information for the outage activities are contained in the RO 23 ISI Final Outage Report and may be obtained through the Progress Energy Carolinas, Inc. plant document control services.3.0 EDDY CURRENT EXAMINATION 3.1 No Eddy-Current testing was performed during refueling outage 23.4t of 43
 
===4.0 INSERVICE===
 
EXAMINATION EVALUATION 4.1 The ISI exams performed prior to and during refueling outage twenty three at H.B. Robinson, Unit 2, Nuclear Station were conducted in accordance with the outage plan derived from the Fourth Ten Year Inservice Inspection Program and Plan. This plan meets the requirements of ASME Section Xl as defined in the 1995 Edition, thru the 1996 Addenda, H. B. Robinson, Unit 2, Technical Specifications, Section 5.5, and Title 10 of the Code of Federal Regulations, Part 50.55a(g) including those applicable relief requests approved by the Nuclear Regulatory Commission for the Fourth Ten-Year Interval.4.2 All Inservice Examinations performed were conducted by the use of Progress Energy procedures and documented on procedural data reports. Each data report details the component or system examined, examination method employed, the procedure used to perform the test and all pertinent equipment settings or examination conditions.
Recordable indications were documented and evaluated within the individual data reports. The examination and evaluations reports are retained in the RO 23 ISI Final Outage Report and are retained by H. B. Robinson Nuclear Station as permanent records for retrieval and review for the life of the plant. A summary of examinations, attached herein, contains listings of the examinations performed, details of the component identification, code category, code item number, examination area, work documents and other applicable identifying information.
4.3 Ultrasonic, magnetic particle, and liquid penetrant examinations revealed no service-induced flaws exceeding the acceptance criteria of ASME Section Xl, 1995 Edition, thru 1996 Addenda.4.4 Visual examinations of supports, which revealed indications requiring evaluation, have been dispositioned per TAAM-038 as functional.
All reported indications on supports were evaluated by Civil Engineering to determine if the supports were functional and had no operability concerns.
However, in some cases, Progress Energy Carolinas, Inc. has elected to restore the supports to their original design 5 of 43 via the WR (Work Request) and WO (Work Order) process and will be re-inspected (if required) to ensure those components have been returned to their design condition.
4.5 The results of examinations performed at the H. B. Robinson Nuclear Station during refueling outage twenty-three are classified into one of the following categories:
Sat -No Rejectable Indications UnSat -Rejectable Indications 4.6 The Inservice Examination Summary tables (TAB B) itemize the components examined during refueling outage twenty-three.
The percent Code required volume (CRV) or Code required area (CRA) covered during the examination, if less than or equal to 90%, is delineated in the comment section of the examination.
The following is a brief explanation of the type of information included in the NDE Summary:* Summary No. -Unique tracking number utilized within the ISI Program/Plan.
* Component ID -Identification of the component examined or tested* Component Description
-A description of the component configuration
* Categorv -The ASME code category that the examination was performed to.* Item -The item number of the applicable code category that the examination was performed to.* Procedure
-The procedure utilized to perform the examination.
* Method -The examination or test method* Report # -The unique examination number assigned to an exam.* Results -The results of the examination
* System -The system on which the component was examined* ISO Number -The isometric drawing identifying the location of the component being examined.* Exam Date -The date the examination was completed.
6 of 43
 
===5.0 AUGMENTED===
 
EXAMINATION PROGRAM 5.1 The Augmented Examination Program included in this report documents the inspections performed to satisfy regulatory documents, other than ASME Section Xl. During this period, ultrasonic; examinations were conducted in accordance with NRC commitment ID 92R0362 for the steam generator feedwater nozzles (79-13). These examinations and records are not subject to the interface and review by the Authorized Nuclear Inservice Inspector (ANII), and are summarized in the Augmented Examination Summary, TAB C, of this Report.6.0 OWNER ELECTED EXAMINATION PROGRAM 6.1 There were no Owner Elected exams performed during RO-23 for this NIS-1 reporting period.7.0 PRESERVICE EXAMINATION
 
===7.1 Preservice===
 
examination of Code Class components were conducted at the H.B.Robinson Unit 2 Plant from the close of refueling outage twenty-two (May 29, 2004) to the close of RO-23 (October 27, 2005) were performed to the requirements of ASME Section Xi 1995 Edition, thru 1996 Addenda. A summary of these examinations and the results are listed in the Preservice Examination Summary, TAB E, of this report.7.2 The detailed examination data sheets recording all of the volumetric, surface and visual results for the preservice examinations are located in the RO 23 ISI Final Outage Report, and may be obtained through the Progress Energy Carolinas, Inc., H.B. Robinson Plant Document Control Services.7 of 43
 
===8.0 PRESSURE===
TEST
 
==SUMMARY==
 
===8.1 Pressure===
tests and VT-2 examinations are performed in conjunction with ASME Section Xl, Plant Technical Specifications and in accordance with procedure TMM-020 "Inservice Inspection Pressure Testing".
Also included within TMM-020 are the approaches to testing each Code Class system and reference to the respective Engineering Surveillance Test (EST) procedures used in the conduct of the credited pressure test. The summary of these pressure tests is listed in the Pressure Test Summary, TAB F, of this Report.8.2 TAB F of this report includes the pressure tests performed after the close of the last NIS-1 reporting period (5/29/2004) thru the end of the First Period (2/19/2005).
TAB F also includes pressure tests performed to date from the start of the Second Period thru this reporting period (10/27/2005).
 
===9.0 REPAIR===
AND REPLACEMENT PROGRAM 9.1 The H. B. Robinson Nuclear Station Repair and Replacement Program reporting period for the Fourth Ten-Year Interval is from the close of refueling outage twenty-two (May 29, 2004) to the close of refueling outage twenty three (October 27, 2005). Repair/replacement activities that occurred during this time frame underwent extensive review by the station personnel involved and the Authorized Nuclear Inservice Inspector (ANII). Work Order package information included within this summary report are those items which have completed all the required reviews, final engineering approval, and the required ANI/ANII NIS-2 certification prior to the close of the reporting period as specified in ASME Section Xl, IWA-6230(b). The repair/replacement summaries are listed in the Repair/Replacement Summary, TAB H, of this Report.8 of 43 9.2 Work Order evolutions performed during the twenty third refueling outage whose document review, approval and certification process was not finalized by the established closing date shall be reported either by amendment to the original Refueling Outage Twenty Three NIS-2 Summary or shall be included in the next refueling outage Summary Report (RO-24), within the established guidelines of ASME Section Xl, IWA-6230(b).
9.2.1 The enclosed repair and replacement summary (TAB H) and the attached ASME Section Xl, NIS-2 forms (Attachment I) detail the component, system, Work Order document, component description and the description of the Work Order activity.
Complete repair and replacement documentation for the specific component is maintained on site as a permanent record and is retrievable through the WO (Work Order) document package, which is identified on the NIS-2 form.9.3 The Owners Report for Repair/Replacement Activities, Form NIS-2 is provided in Attachment I.9 of 43 INSERVICE INSPECTION REPORT REFUELING OUTAGE 22 INDEX OF EXAMINATIONS TAB EXAMINATION ACTIVITY A EDDY CURRENT
 
==SUMMARY==
B INSERVICE EXAMINATION
 
==SUMMARY==
C AUGMENTED EXAMINATION
 
==SUMMARY==
D OWNER ELECTED EXAMINATION
 
==SUMMARY==
E PRESERVICE EXAMINATION
 
==SUMMARY==
F PRESSURE TEST
 
==SUMMARY==
G H EXAMINATION PERCENTAGE
 
==SUMMARY==
REPAIR / REPLACEMENT
 
==SUMMARY==
ATTACHMENT I I REPAIR/REPLACEMENT NIS-2 FORMS 10 of 43 TAB A EDDY CURRENT
 
==SUMMARY==
11 of 43 EDDY CURRENT
 
==SUMMARY==
ABSTRACT No Eddy-Current Testing was performed during refueling outage 23.12 of 43 TAB B INSEERVICE EXAMINATION
 
==SUMMARY==
13 of 43 The following tables are arranged by ASME Code Class and CPL component identification.
The 100 series are ASME Class 1, and the 200 series are ASME Class 2.Code Required Volume (CRV) and Code Required Surface (CRS) have been identified throughout the ISI Summary Tables. When an examination is limited to < 90% CRV or CRS as defined in ASME Code Case N-460 and NRC Information Notice 98-42, a relief request shall be submitted within 12 months of the close of the Fourth Ten-Year Interval.
Generic Code Cases that apply to all examinations are not specifically identified for each examination.
114 of 43 INSERVICE EXAMINATION
 
==SUMMARY==
Summary No.Exam Date Component ID Component Description Cateqory Item Procedure Method/Report
#/Results System ISO Number Class 1 31400 105A101 TUBESHEET TO HEAD B-B B2.40 NDEP-0450 NDEP-0450 NDEP-0450 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.to welded insulation ring pads and a welded ID plate.31700 105AIC SUPPORT LEG C F-A F1.40 NDEP-0613 Comment: Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.UT UT-05-053 Sat 2005 HBR2-10618 SHT 007 10/4/2005 UT UT-05-051 Sat 2005 HBR2-10618 SHT 007 10/4/2005 UT UT-05-052 Sat 2005 HBR2-10618 SHT 007 10/4/2005 Code Case N-460 invoked for this exam for which 94.840% CRV was achieved due VT VT-05-036 Sat 2005 HBR2-10618 SHT 007 10/4/2005 37500 107A/04DM ELBOW TO NOZZLE B-F B5.70 NDEP-0436 NDEP-0201 NDEP-0436 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.in a single sided exam from the centrifugally cast stainless steel elbow side with 49.1% CRV.37600 107AJ05DM NOZZLE TO ELBOW B-F B5.70 NDEP-0436 NDEP-0201 NDEP-0436 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.in a single sided exam from the centrifugally cast stainless steel elbow side with 47.540% CRV.37800 107A/06 ELBOW TO PIPE B-J B9.11 NDEP-0436 NDEP-0436 NDEP-0201 NDEP-0425 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.37900 107A/07 PIPE TO ELBOW B-J B9.11 NDEP-0201 NDEP-0436 NDEP-0425 NDEP-0436 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.38400 107A112 PIPE TO PIPE B-J B9.11 NDEP-0201 NDEP-0425 Comment: Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.UT UT-05-048 Sat 2005 HBR2-10618 SHT 011 10/1/2005 PT PT-05-097 Sat 2005 HBR2-10618 SHT 011 9/29/2005 UT UT-05-040 Sat 2005 HBR2-10618 SHT 011 10/1/2005 Examination was limited due to steam generator nozzle configuration which resulted UT UT-05-049 Sat 2005 HBR2-10618 SHT 011 10/1/2005 PT PT-05-098 Sat 2005 HBR2-10618 SHT 011 9/30/2005 UT UT-05-050 Sat 2005 HBR2-10618 SHT 011 10/1/2005 Examination was limited due to steam generator nozzle configuration which resulted UT UT PT UT PT UT UT UT UT-05-041 UT-05-042 PT-05-099 UT-05-043 PT-05-100 UT-05-044 UT-05-046 UT-05-045 Sat Sat Sat Sat 2005 2005 2005 2005 HBR2-10618 SHT 011 HBR2-10618 SHT 011 HBR2-10618 SHT 011 HBR2-10618 SHT 011 HBR2-10618 SHT 011 HBR2-10618 SHT 011 HBR2-10618 SHT 011 HBR2-10618 SHT 011 10/1/2005 10/1/2005 9/30/2005 10/1/2005 9/30/2005 10/1/2005 10/1/2005 10/1/2005 Sat Sat Sat Sat 2005 2005 2005 2005 PT PT-05-101 Sat UT UT-05-047 Sat 2005 HBR2-10618 SHT 011 2005 HBR2-10618 SHT 011 10/2/2005 10/3/2005 15 of 43 INSERVICE EXAMINATION
 
==SUMMARY==
Summary No. Component ID Exam Date Component Description Cateaorv Item Procedure Method/Report
#/Results System ISO Number 48000 Comment: 48100 Comment: 48200 Comment: 48300 Comment: 49000 Comment: 67800 Comment: 67900 Comment: 69200 Comment: 100400 Comment: 112700 Comment: 112800 Comment: 112900 Comment: 113000 Comment: 113100 Comment: 111/11 ELBOW TO PIPE 6-J B9.11 NDEP-0425 UT UT-05-059 Sat NDEP-0201 PT PT-05-102 Sat Examination was performed to the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.111112 PIPE TO ELBOW B-J 69.11 NDEP-0425 UT UT-05-061 Sat NDEP-0201 PT PT-05-103 Sat Examination was performed to the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.111/13 ELBOW TO PIPE B-J B9.11 NDEP-0425 UT UT-05-062 Sat NDEP-0201 PT PT-05-104 Sat Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.111114 PIPE TO ELBOW B-J B9.11 NDEP-0425 UT UT-05-060 Sat NDEP-0201 PT PT-05-105 Sat Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.111/Si-875B(B)
VALVE SI-8758 BOLTING B-G-2 67.70 NDEP-0611 VT VT-05-001 Sat Exam performed in place under tension to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.118A/RC-551B(B)
VALVE RC-551B BOLTING B-G-2 B7.70 NDEP-0611 VT VT-05-039 Sat Exam performed in place, under tension to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.118AIRC-551B(FB)
VALVE RC-551B FLANGE BOLTING B-G-2 B7.50 NDEP-0611 VT VT-05-040 Sat Exam performed in place, under tension to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.120/01 BRANCH CONNECTION TO CAP B-J B9.21 NDEP-0201 PT PT-05-094 Sat Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.130/03 PIPE TO VALVE SI.873E WELD B-J B9.40 NDEP-0201 PT PT-05-106 Sat Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.133/08 PIPE TO ELBOW B-J B9.40 NDEP-0201 PT PT-05-076 Sat Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.133/09 ELBOW TO PIPE B-J B9.40 NDEP-0201 PT PT-05-077 Sat Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.133/10 PIPE TO ELBOW B-J B9.40 NDEP-0201 PT PT-05-078 Sat Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.133/11 ELBOW TO PIPE B-J 69.40 NDEP-0201 PT PT-05-079 Sat Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.133/12 PIPE TO ELBOW B-J 89.40 NDEP-0201 PT PT-05-080 Sat Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.2080 2080 2080 2080 2080 2080 2080 2080 2005 2005 2005 2005 2080 2060 2060 2060 2060 2060 HBR2-10618 SHT 016 HBR2-10618 SHT 016 HBR2-10618 SHT 016 HBR2-10618 SHT 016 HBR2-10618 SHT 016 HBR2-10618 SHT 016 HBR2-10618 SHT 016 HBR2-10618 SHT 016 HBR2-10618 SHT 016 HBR2-10618 SHT 027 HBR2-10618 SHT 027 HBR2-10618 SHT 030 HBR2-10618 SHT 042 HBR2-10618 SHT 045 HBR2-10618 SHT 045 HBR2-10618 SHT 045 HBR2-10618 SHT 045 HBR2-10618 SHT 045 10/6/2005 10/2/2005 10/6/2005 10/2/2005 10/6/2005 10/2/2005 10/6/2005 10/2/2005 9/17/2005 10/5/2005 10/5/2005 9/29/2005 10/3/2005 9/28/2005 9/28/2005 9/28/2005 9/28/2005 9/28/2005 16 of 43
=Summary No.113200 Comment: 113300 Comment: 113400 Comment: 113700 Comment: 113800 Comment: 113900 Comment: 11i4000 Comment: 116800 Comment: 122700 Comment: 122800 Comment: 122900 Comment: 138300 Comment: 138400 Comment: 138500 Comment: 138600 Comment: 138700 5 INSERVICE EXAMINATION
 
==SUMMARY==
Component ID Component Description Category Item Procedure Method/Report
#/Results 133/12A ELBOW TO PIPE B-J B9.40 NDEP-0201 PT PT-05-081 Sat Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.133/12B PIPE TO ELBOW B-J 89.40 NDEP-0201 PT PT-05-082 Sat Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.133/13 ELBOW TO PIPE B-J B9.40 NDEP-0201 PT PT-05-083 Sat Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.133/14 PIPE TO ELBOW B-J B9.40 NDEP-0201 PT PT-05-084 Sat Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.133/15 ELBOW TO PIPE B-J 89.40 NDEP-0201 PT PT-05-085 Sat Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.133/16 PIPE TO ELBOW B-J B9.40 NDEP-0201 PT PT-05-086 Sat Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.133/17 ELBOW TO PIPE B-J 89.40 NDEP-0201 PT PT-05-087 S;t Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.133/FLG1(FB)
FLANGE I BOLTING B-G-2 87.50 NDEP-0611 VT VT-05-044 Sat Exam performed in place, under tension to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.134/D CLEVIS ROD HANGER F-A F1.10 NDEP-0613 VT VT-05-049 Sat Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.134/E-WS WELDED ANCHOR F-A F1.10 NDEP-0613 VT VT-05-050 Sat Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.134/F CLEVIS ROD HANGER F-A F1.10 NDEP-0613 VT VT-05-051 Sat Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.143/18 PIPE TO ELBOW B-J 89.40 NDEP-0201 PT PT-05-095 Sat Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.143/19 ELBOW TO PIPE B-J B9.40 NDEP-0201 PT PT-05-096 Sat Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda 143/19A PIPE TO ELBOW B-J 89.40 NDEP-0201 PT PT-05-088 Sat Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.143/19B ELBOW TO PIPE B-J B9.40 NDEP-0201 PT PT-05-089 Sat Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.143/20 PIPE TO ELBOW B-J B9.40 NDEP-0201 PT PT-05-090 Sat System Exam Date ISO Number 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 2060 HBR2-10618 SHT 045 HBR2-10618 SHT 045 HBR2-10618 SHT 045 HBR2-10618 SHT 045 HBR2-10618 SHT 045 HBR2-10618 SHT 045 HBR2-10618 SHT 045 HBR2-10618 SHT 045 HBR2-10618 SHT 046 HBR2-10618 SHT 046 HBR2-10618 SHT 046 HBR2-10618 SHT 055 HBR2-10618 SHT 055 HBR2-10618 SHT 055 HBR2-10618 SHT 055 HBR2-10618 SHT 055 9/28/2005 9/28/2005 9/28/2005 9/28/2005 9/28/2005 9/28/2005 9/28/2005 10/6/2005 10/6/2005 10/6/2005 10/6/2005 9/29/2005 9/29/2005 9/28/2005 9/28/2005 9/28/2005 17 of 43 INSERVICE EXAMINATION
 
==SUMMARY==
Summary No.Exam Date Component ID Component Description Cateqorv Item Procedure MethodlReoort
#/Results Svstem ISO Numhber Comment: Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.138800 143/21 ELBOW TO PIPE B-J B9.40 NDEP-0201 Comment: Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.138900 143/22 PIPE TO ELBOW B-J B9.40 NDEP-0201 Comment: Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.139000 143/23 ELBOW TO PIPE B-J B9.40 NDEP-0201 Comment: Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.142900 143/N TRAPEEZE HANGER W/U-BOLT F-A F1.10 NDEP-0613 Comment: Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.143000 143/P U-BOLT RESTRAINT F-A F1.10 NDEP-0613 Comment: Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.143200 143/S11WS WELDED ANCHOR F-A F1.10 NDEP-0613 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.PT PT-05-091 Sat PT PT-05-092 Sat PT PT-05-093 Sat VT VT-05-037 Sat VT VT-05-038 Sat VT VT-05-035 Sat 2060 HBR2-10618 SHT 055 2060 HBR2-10618 SHT 055 2060 HBR2-10618 SHT 055 2060 HBR2-10618 SHT 055 2060 HBR2-10618 SHT 055 2060 HBR2-10618 SHT 055 9/28/2005 9/28/2005 9/28/2005 10/4/2005 10/4/2005 10/3/2005 150400 150500 150600 150700 150800 150900 151000 151100 151200 151300 151400 151500 151600 151700 151800 151900 152000 152100 152200 144/B-N01 144/B-N02 144/B-N03 144/B-N04 144/B-NOS 144/B-NO6 144/B-N07 144/B-N08 144/B-N09 144/B-N10 144/B-N1l 144/B-N12 144/B-N13 144/B-N14 144/B-N15 144/B-N16 144/B-N17 144/B-N18 144/B-N19 RCP B NUT I RCP B NUT 2 RCP B NUT 3 RCP B NUT 4 RCP B NUT 5 RCP B NUT 6 RCP B NUT 7 RCP B NUT 8 RCP B NUT 9 RCP B NUT 10 RCP B NUT 11 RCP B NUT 12 RCP B NUT 13 RCP B NUT 14 RCP B NUT 15 RCP B NUT 16 RCP B NUT 17 RCP B NUT 18 RCP B NUT 19 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B-G-1 B6.200 86.200 B6.200 B6.200 B6.200 86.200 B6.200 B6.200 B6.200 B6.200 B6.200 B6.200 B6.200 B6.200 B6.200 B6.200 B6.200 B6.200 B6.200 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 NDEP-0611 VT VT VT VT VT VT VT VT VT VT VT VT VT VT VT VT VT VT VT VT-05-008 VT-05-01 0 VT-05-011 VT-05-012 VT-05-013 VT-05-014 VT-05-015 VT-05-016 VT-05-017 VT-05-018 VT-05-019 VT-05-020 VT-05-021 VT-05-022 VT-05-023 VT-05-024 VT-05-025 VT-05-026 VT-05-027 Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 9/23/2005 9/2312005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 18 of 43 INSERVICE EXAMINATION
 
==SUMMARY==
Summary No.Exam Date Comoonent ID Component Description Cateaorv Item Procedure Method/Renort
#/Results System ISO Number.------- I ---1-'-.- ------ --152300 152400 152500 152600 152700 Comment: 1441B-N20 RCP B NUT 20 B-G-1 B6.200 144/B-N21 RCP B NUT 21 B-G-1 B6.200 144/B-N22 RCP B NUT 22 B-G-1 B6.200 144/B.N23 RCP B NUT 23 B-G-1 B6.200 144/B-N24 RCP B NUT 24 8-G-1 86.200 Exam performed in place, under tension to the requirements of ASME Section Xl, 1995 NDEP-0611 VT VT-05-028 NDEP-0611 VT VT-05-029 NDEP-0611 VT VT-05-030 NDEP-0611 VT VT-05-031 NDEP-0611 VT VT-05-032 Edition, thru 1996 Addenda.Sat Sat Sat Sat Sat 2005 2005 2005 2005 2005 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 152800 152900 153000 153100 153200 153300 153400 153500 153600 153700 153800 153900 154000 154100 154200 154300 154400 154500 154600 154700 154800 154900 155000 155100 Comment: 144/B-S01 RCP B MAIN FLANGE STD1 B-G-1 86.180 NDEP-0439 144/B-S02 RCP B MAIN FLANGE STO 2 B-G-1 86.180 NDEP-0439 144/B-S03 RCP B MAIN FLANGE STD 3 B-G-1 B6.180 NDEP-0439 144/B-S04 RCP B MAIN FLANGE STD 4 B-G-1 B6.180 NDEP-0439 144/B-SO5 RCP B MAIN FLANGE STD 5 B-G-1 86.180 NDEP-0439 144/B-SO6 RCP B MAIN FLANGE STD 6 B-G-1 B6.180 NDEP-0439 144/B-S07 RCP B MAIN FLANGE STD 7 B-G-1 B6.180 NDEP-0439 144/B-S08 RCP B MAIN FLANGE STD 8 B-G-1 B6.180 NDEP-0439 144/B-S09 RCP B MAIN FLANGE STD 9 B-G-1 B6.180 NDEP-0439 144/B-SIO RCP B MAIN FLANGE STD 10 B-G-1 86.180 NDEP-0439 144/B-S11 RCP B MAIN FLANGE STD 11 B-G-1 86.180 NDEP-0439 144/B-512 RCP B MAIN FLANGE STD 12 B-G-1 B6.180 NDEP-0439 144/B-S13 RCP B MAIN FLANGE STD 13 B-G-1 B6.180 NDEP-0439 144/B-S14 RCP B MAIN FLANGE STD 14 B-G-1 B6.180 NDEP-0439 144/B-S15 RCP B MAIN FLANGE STD 15 B-G-1 86.180 NDEP-0439 144/5-S16 RCP B MAIN FLANGE STD 16 B-G-1 86.180 NDEP-0439 144/B-S17 RCP B MAIN FLANGE STD 17 B-G-1 B6.180 NDEP-0439 144/B-S18 RCP B MAIN FLANGE STD 18 8-G-1 86.180 NDEP-0439 144/B-S19 RCP B MAIN FLANGE STD 19 B-G-1 86.180 NDEP-0439 144/B-S20 RCP B MAIN FLANGE STD 20 B-G-1 B6.180 NDEP-0439 144/B-S21 RCP B MAIN FLANGE STD 21 B-G-1 86.180 NDEP-0439 144/B-S22 RCP B MAIN FLANGE STD 22 B-G-1 B6.180 NDEP-0439 144/B-S23 RCP B MAIN FLANGE STD 23 B-G-1 B6.180 NDEP-0439 144/B-S24 RCP B MAIN FLANGE STD 24 8-G-1 86.180 NDEP-0439 Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.UT UT UT UT UT UT UT I T UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT UT-05-001 UT-05-002 UT-05-003 UT-05-004 UT-05-005 UT-05-006 UT-05-007 UT 05-008 UT-05-009 UT-05-010 UT-05-011 UT-OS-012 UT-OS-013 UT-05-014 UT-05-015 UT-OS-016 UT-OS-017 UT-OS-018 UT-OS 019 UT-05-020 UT-05-021 UT-05-022 UT-05-023 UT-05-024 Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat Sat 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 2005 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HRR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 HBR2-10618 SHT 056 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 9/23/2005 155200 144/B-SH-BLT RCP B SEAL HOUSE BOLTING B-G-2 87.60 NDEP-0611 VT VT-05-009 Sat Comment: Exam performed in place, under tension to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.2005 HBR2-10618 SHT 056 19 of 43 INSERVICE EXAMINATION
 
==SUMMARY==
Summary No.Exam nst=Component ID ComDonent Descrintion Catenorv ItPm PmrPriurp MPthnr1l/RPnnrt fi/PPQidk, Rvqfiom IMr Nujmhar-11 ...... ---------
1 " 1. -,- -1.1 Class 2 168800 205A102 TUBESHEET TO STUB BARREL WELD C-A C1.30 NDEP-0450 NDEP-0450 NDEP-0450 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.hand holes and instrumentation taps.168900 205A/03 STUB BARREL TO LOWER SHELL WELD C-A C1.10 NDEP-0450 NDEP-0450 NDEP-0450 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.UT UT-05-036 Sat 3005 HBR2-10618 SHT 062 9/29/2005 UT UT-05-035 Sat 3005 HBR2-10618 SHT 062 9/29/2005 UT UT-05-034 Sat 3005 HBR2-10618 SHT 062 9/29/2005 Code Case N-460 invoked for this exam for which 92.37% CRV was achieved due to UT UT UT UT-05-037 UT-05-038 UT-05-039 Sat Sat Sat 3005 HBR2-10618 SHT 062 3005 HBR2-10618 SHT 062 3005 HBR2-10618 SHT 062 9/28/2005 9/28/2005 9/28/2005 169000 205A/04 UPPER SHELL TO LOWER TRANSITION WELD C-A C1i10 NDEP-0450 NDEP-0450 NDEP-0450 NDEP-0450 NDEP-0450 NDEP-0450 UT UT-05-031 Sat 3005 HBR2-10618 SHT 062 9/28/2005 UT UT-05-030 Sat 3005 HBR2-10618 SHT 062 9127/2005 UT UT-05-033 Sat 3005 HBR2-10618 SHT 062 9/28/2005 UT UT-05-028 Sat 3005 HBR2-10618 SHT 062 9/27/2005 UT UT-05-029 Sat 3005 HBR2-10618 SHT 062 9/27/2005 UT UT-05-032 Sat 3005 HBR2-10618 SHT 062 9/28/2005 Code Case N-460 invoked for this exam for which 98.50% CRV was achieved due Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda. .to welded insulation ring pads.169500 205A/07 UPPER HEAD TO STEAM NOZZLE WELD C-B C2.21 NDEP-0301 NDEP-0450 NDEP-0450 NDEP-0450 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.MT UT UT UT MT-05-002 UT-05-063 UT-05-064 UT-05-065 Sat Sat Sat Sat 3005 3005 3005 3005 HBR2-10618 SHT 062 HBR2-10618 SHT 062 HBR2-10618 SHT 062 HBR2.10618 SHT 062 10/14/2005 10/15/2005 10/15/2005 10115/2005 10/5/2005 178500 2121R-WS WELDED BOX RESTRAINT F-A F1.20 NDEP-0613 VT VT-05-043 Eval 3020 HBR2-10618 SHT 071 Evaluation Disposition Acceptable:
Support has been evaluated as functional, work request (WR 212019) has been generated to remove loose coatings and reapply.Comment: Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda. Examination revealed coating degradation
-flaking and peeling paint. Support has been evaluated as functional, work request (WR 212019) has been generated to remove loose coatings and reapply.179500 213/01 SG B NOZZLE TO REDUCING ELBOW C-F-2 C5.51 NDEP-0437 NDEP-0437 NDEP-0301 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.UT UT-05-066 Sat UT UT-05-067 Sat MT MT-05-001 Sat 3020 HBR2-10618 SHT 072 3020 HBR2-10618 SHT 072 3020 HBR2-10618 SHT 072 10/15/2005 10/15/2005 10/14/2005 20 of 43 INSERVICE EXAMINATION
 
==SUMMARY==
Summary Exam No. Component ID Component Description Category Item Procedure Method/Report
#/Results System ISO Number Date 180800 213/12 PIPE TO ELBOW C-F-2 C5.51 NDEP-0437 UT UT-05-054 Sat 3020 HBR2-10618 SHT 072 10/5/2005 NDEP-0437 UT UT-05-055 Sat 3020 HBR2-10618 SHT 072 10/5/2005 NDEP-0201 PT PT-05-111 Sat 3020 HBR2-10618 SHT072 10/4/2005 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda. PT performed in lieu of MT due to limited access of whip restraint.
180900 213/13 ELBOW TO PIPE C-F-2 C5.51 NDEP-0437 UT UT-05-058 Sat 3020 HBR2-10618 SHT 072 10/5/2005 NDEP-0437 UT UT-05-057 Sat 3020 HBR2-10618 SHT 072 10/5/2005 NDEP-0437 UT UT-05-056 Sat 3020 HBR2-10618 SHT 072 10/5/2005 NDEP-0201 PT PT-05-112 Sat 3020 HBR2-10618 SHT 072 10/4/2005 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda, PT performed in lieu of MT due to limited access of whip restraint.
182500 213/C SPRING HANGER F-A F1.20 NDEP-0613 VT VT-05-041 Eval 3020 HBR2-10618 SHT 072 10/5/2005 Evaluation Disposition Acceptable:
Support has been evaluated as acceptable as is, no further action required.Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda. Examination identified there was no scale on spring can. Measured slot length 3.7" Indicator was 2.1" from top of slot. Civil Engineering evaluated the support as acceptable as is, no further action required.182800 213/F-WS WELDED BOX RESTRAINT F-A F1.20 NDEP-0613 VT VT-05-042 Eva1 3020 HBR2-10618 SHT 072 10/5/2005 Evaluation Disposition Acceptable:
Support was evaluated as acceptable as is, however, support will be restored to original design configuration under WR 211601.Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda. Examination identified weld (5") is not adhered to the plate/web intersection.
Civil Engineering evaluated the support as acceptable as is: however, support will be restored to original design configuration under WR 211601.319700 246/03 PIPE TO ELBOW C-F-1 C5.30 NDEP-0201 PT PT-05-107 Sat 2080 HBR2-10618 SHT 112 10/3/2005 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.319800 246/04 ELBOW TO PIPE C-F-1 C5.30 NDEP-0201 PT PT-05-108 Sat 2080 HBR2-10618 SHT 112 10/3/2005 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.319900 246/05 PIPE TO ELBOW C-F-1 C5.30 NDEP-0201 PT PT-05-109 Sat 2080 HBR2-10618 SHT 112 1013/2005 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.320000 246/06 ELBOW TO PIPE C-F-1 C5.30 NDEP-0201 PT PT-05-110 Sat 2080 HBR2-10618 SHT 112 10/3/2005 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.325300 246/1 U-BOLT TRAPEEZE ROD HANGER F-A F1.20 NDEP-0613 VT VT-05-045 Eval 2080 HBR2-10618 SHT 112 10/6/2005 Evaluation Disposition Acceptable:
Support has been evaluated as acceptable as is, no further action required.Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda, Examination identified 3/4 thread engagement on clamp to pipe bolting. Civil Engineering has evaluated the support as acceptable as is, no further action required.325500 246/K-WS WELDED U-BOLT RESTRAINT F-A F1.20 NDEP-0613 VT VT-05-046 Sat 2080 HBR2-10618 SHT 112 10/6/2005 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.21 of 43 INSERVICE EXAMINATION
 
==SUMMARY==
Summary No.Exam Date Component ID Component Description Cateaorv Item Procedure Method/Report
#/Results System ISO Numher 332600 247/D SPRING HANGER F-A F1.20 NDEP-0613 VT VT-05-048 Eval 2080 HBR2-10618 SHT 113 10/6/2005 Evaluation Disposition Acceptable:
Support has been evaluated as acceptable as is, no further actions required.Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda, Examination identified a loose nut on U support to clevis. No Scale On Spring Can, slot is 1.9", pointer is at 1.13". Civil Engineering evaluated the missing load scale as acceptable as is. The clevis pin nut was tightened to enhance margin of threads and tightness.
333600 247/N ANGLE IRON SUPPORT F-A F1.20 NDEP-0613 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.VT VT-05-047 Sat 2080 HBR2-10618SHT 113 10/6/2005 22 of 43 TAB C AUGMENTED EXAMINATION
 
==SUMMARY==
23 of 43 AUGMENTED EXAMINATION
 
==SUMMARY==
Summary Exam No. Component ID Component Description Category Item Procedure Method/Report
#/Results System ISO Number Date 192300 215/79-13-A SIG A NOZZLE TO ELBOW AUGMENT E-1 NDEP-0437 UT UT-05-025 Sat 3050 HBR2-10618 SHT 074 9/26/2005 Comment: Augmented examination completed to the requirements of NRC Bulletin No. 79-13, "Cracking in Feedwater System Piping". No recordable indications were noted. Maintained a 5% to 20% ID roll during examination.
Scanned 360&deg; of base metal/weld from nozzle taper to 18" on upstream side of elbow.197200 216/79-13-B S/G B NOZZLE TO ELBOW AUGMENT E-1 NDEP-0437 UT UT-05-026 Sat 3050 HBR2-10618 SHT 075 9/26/2005 Comment: Augmented examination completed to the requirements of NRC Bulletin No. 79-13, "Cracking in Feedwater System Piping". No recordable indications were noted. Maintained a 5% to 20% Id roll during examination.
Scanned 3600 of base metal/weld from nozzle taper to 18" on upstream side of elbow.201000 217/79-13-C S/G C NOZZLE TO ELBOW AUGMENT E-1 NDEP-0437 UT UT-05-027 Sat 3050 HBR2-10618 SHT 076 9/26/2005 Comment: Augmented examination completed to the requirements of NRC Bulletin No. 79-13, "Cracking in Feedwater System Piping". No recordable indications were noted. Maintained a 5% to 20% Id roll during examination.
Scanned 360&deg; of base metal/weld from nozzle taper to 18" on upstream side of elbow.24 of 43 TAB D OWNER' ELECTED EXAM I NATION
 
==SUMMARY==
25 of 43 OWNER ELECTED EXAMINATION
 
==SUMMARY==
Component NDE Method Exam ISO Exam Summary No Identification Component Description Category Item Procedure Report # Results System Number Date There were no Owner Elected exams performed during RO-23 for this NIS-1 reporting period.26 of 43 TAB E PRESERVICE EXAM INATION
 
==SUMMARY==
27 of 43 Pre-Service Examination Summary Summary No.Exam System ISO Number Date Component ID Component Description Category Item Procedure Method/Report
#/Results 25950 Comment: 25975 Comment: 26025 Comment: 26050 Comment: 26575 Comment: 26625 Comment: 26650 Comment: 26675 Comment: 26725 Comment: 26750 Comment: 26775 Comment: 26825 Comment: 26850 Comment: 26875 Comment: 26925 Comment: 101C126(a)
TOP ROD TRAVEL HOUSING WELD B-0 B14.10 NDEP-0201 PT PT-05-003 Sat Preservice examination performed to meet the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.101C/26(f)
BOTTOM CRDM HEAD ADAPTER WELD B-a B14.10 NDEP-0201 PT PT-05-004 Sat Preservice examination performed to meet the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.II0C/27(a)
TOP ROD TRAVEL HOUSING WELD B-a B14.10 NDEP-0201 PT PT-05-005 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C127(f)
BOTTOM CRDM HEAD ADAPTER WELD B-a B14.10 NDEP-0201 PT PT-05-006 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C/28(a)
TOP ROD TRAVEL HOUSING WELD B-a B14.10 NDEP-0201 PT PT-05-007 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.IOIC/28(fl BOTTOM CRDM HEAD ADAPTER WELD B-a B14.10 NDEP-0201 PT PT-05-008 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C/29(a)
TOP ROD TRAVEL HOUSING WELD B-O B14.10 NDEP-0201 PT PT-05-009 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition. thru 1996 Addenda.101CI29(fl BOTTOM CRDM HEAD ADAPTER WELD B-a B14.10 NDEP-0201 PT PT-05-010 Sat Preservice examination performed to meet the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.101C/30(a)
TOP ROD TRAVEL HOUSING WELD B-a B14.10 NDEP-0201 PT PT-05-011 Sat Preservice examination performed to meet the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.101C/30(f)
BOTTOM CRDM HEAD ADAPTER WELD B-a B14.10 NDEP-0201 PT PT-05-012 Sat Preservice examination performed to meet the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.101C/31(a)
TOP ROD TRAVEL HOUSING WELD B-a B14.10 NDEP-0201 PT PT-05-013 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C131(fl BOTTOM CRDM HEAD ADAPTER WELD B-a B14.10 NDEP-0201 PT PT-05-014 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C/32(a)
TOP ROD TRAVEL HOUSING WELD B-a B14.10 NDEP-0201 PT PT-05-015 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C/32(t BOTTOM CRDM HEAD ADAPTER WELD B-a B14.10 NDEP-0201 PT PT-05-016 Sat Preservice examination performed to meet the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.101C/33(a)
TOP ROD TRAVEL HOUSING WELD B-a B14.10 NDEP-0201 PT PT-05-017 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.1005 1005 1005 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SH i 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4i82G05 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 28 of 43 Pre-Service Examination Summary Component Description Category Item Procedure Method/Report
#/Results Summary No.Exam-System ISO Number Date Comoonent ID 26950 Comment: 26975 Comment: 27025 Comment: 27050 Comment: 27075 Comment: 27125 Comment: 27150 Comment: 27175 Comment: 27225 Comment: 27250 Comment: 27275 Comment: 27325 Comment: 27350 Comment: 27375 Comment: 27425 Comment: 101C/33(f)
BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-018 Sat Preservice examination performed to meet the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.101C/34(a)
TOP ROD TRAVEL HOUSING WELD B-0 B14.10 NDEP-0201 PT PT-05-019 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C,/34(f)
BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-020 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C/35(a)
TOP ROD TRAVEL HOUSING WELD B-O B14.10 NDEP-0201 PT PT-05-021 Sat Preservice examination performed to meet the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.101C135(f)
BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-022 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C136(a)
TOP ROD TRAVEL HOUSING WELD B-0 B14.10 NDEP-0201 PT PT-05-023 Sat Preservice examination performed to meet the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.101C/36(f)
BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-024 Sat Preservice examination performed to meet the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.101C/37(a)
TOP ROD TRAVEL HOUSING WELD B-0 614.10 NDEP-0201 PT PT-05-025 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C/37(f)
BOTTOM CRDM HEAD ADAPTER WELD B-O B14.10 NDEP-0201 PT PT-05-026 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C/38(a)
TOP ROD TRAVEL HOUSING WELD B-O B14.10 NDEP-0201 PT PT-05-027 Sat Preservice examination performed to meet the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.101C/38(fl BOTTOM CRDM HEAD ADAPTER WELD B-0 614.10 NDEP-0201 PT PT-05-028 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C/39(a)
TOP ROD TRAVEL HOUSING WELD B-0 B14.10 NDEP-0201 PT PT-05-029 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C/39(fl BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-030 Sat Preservice examination performed to meet the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.101C/40(a)
TOP ROD TRAVEL HOUSING WELD B-0 B14.10 NDEP-0201 PT PT-05-031 Sat Preservice examination performed to meet the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.101C/40(f)
BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-032 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.29 of 43 1005 1005 1005 1005 1005 1005 1005 1005 1005 1005 1005 1005 1005 1005 1005 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 HBR2-10618 SHT 004 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 Pre-Service Examination Summary Summary No. Component ID Exam ISO Number Date Comoonent Description Cateaorv Item Procedure Method/Report
#/Results Svstem 27450 Comment: 27475 Comment: 27525 Comment: 27550 Comment: 27575 Comment: 101 C/41 (a) TOP ROD TRAVEL HOUSING WELD B-0 B14.10 NDEP-0201 PT PT-05-033 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.10 11C/41 (f) BOTTOM CRDM HEAD ADAPTER WELD B-O B14.10 NDEP-0201 PT PT-05-034 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C142(a)
TOP ROD TRAVEL HOUSING WELD B-O B814.10 NDEP-0201 PT PT-05-035 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda, 1 01 C142(f) BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-036 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C/43(a)
TOP ROD TRAVEL HOUSING WELD B-0 B14.10 NDEP-0201 PT PT-05-037 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.1005 1005 HBR2-10618 SHT 004 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 27625 410C,'43(01 BOTTOM CRDM HEAD ADAPTER WELD B-O B14.10 NDEP-0201 PT PT-05-038 Sat Comment: Preservice examination performed to meet the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.27650 101C/44(a)
TOP ROD TRAVEL HOUSING WELD B-O B14.10 NDEP-0201 PT PT-05-039 Sat Comment: Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.27675 101C/44(fl BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-040 Sat Comment: Preservice examination performed to meet the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.27725 101C/45(a)
TOP ROD TRAVEL HOUSING WELD B-0 B14.10 NDEP-0201 PT PT-05-041 Sat Comment: Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.27750 101C/45(fl BOTTOM CRDM HEAD ADAPTER WELD B-O B14.10 NDEP-0201 PT PT-05-042 Sat Comment: Preservice examination performed to meet the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.27775 101C/62(a)
TOP ROD TRAVEL HOUSING WELD B-0 B14.10 NDEP-0201 PT PT-05-043 Sat Comment: Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.27825 101C/62(f)
BOTTOM CRDM HEAD ADAPTER WELD B-0 814.10 NDEP-0201 PT PT-05-044 Sat Comment: Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 27850 Comment: 27875 Comment: 101C/63(a)
TOP ROD TRAVEL HOUSING WELD B-0 814.10 NDEP-0201 PT PT-05-045 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.101C/63(f)
BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-046 Sat Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.30 of 43 Pre-Service Examination Summary Summary No.Component ID Component Description Exam System ISO Number Date Category Item Procedure Method/Report
#/Results 27925 101C/64(a)
TOP ROD TRAVEL HOUSING WELD B-0 B14,10 NDEP-0201 PT PT-05-047 Sat Comment: Preservice examination performed to meet the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda.27950 101C164(f)
BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-048 Sat Comment: Preservice examination performed to meet the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.27975 101C/65(a)
TOP ROD TRAVEL HOUSING WELD B-O B14.10 NDEP-0201 PT PT-05-049 Sat Comment: Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.28025 101C/65(f)
BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-050 Sat Comment: Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.28050 101C/66(a)
TOP ROD TRAVEL HOUSING WELD B-0 B14.10 NDEP-0201 PT PT-05-051 Sat Comment: Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.28075 101C/66(f)
BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-052 Sat Comment: Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition. thru 1996 Addenda.28125 101C/67(a)
TOP ROD TRAVEL HOUSING WELD B-0 B14.10 NDEP-0201 PT PT-05-053 Sat Comment: Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.28150 101C167(f)
BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-054 Sat Comment: Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.28175 101C/68(a)
TOP ROD TRAVEL HOUSING WELD B-O B14.10 NDEP-0201 PT PT-05-055 Sat Comment: Preservice examination performed to meet the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda.28225 10IC/68(f)
BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-056 Sat Comment: Preservice examination performed to meet the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.28250 101C/69(a)
TOP ROD TRAVEL HOUSING WELD B-0 B14.10 NDEP-0201 PT PT-05-057 Sat Comment: Preservice examination performed to meet the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.28275 101C/69(f)
BOTTOM CRDM HEAD ADAPTER WELD B-0 B14.10 NDEP-0201 PT PT-05-058 Sat Comment: Preservice examination performed to meet the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda.1005 1005 HBR2-10618 SHT 004 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 1005 HBR2-10618 SHT 004 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 4/8/2005 9/25/2005 9/29/2005 10/3/2005 322800 246/26 PIPE TO VALVE SI-873B WELD C-F-1 C5.30 NDEP-0201 PT PT-05-070 Sat 2080 HBR2-10618 SHT 112 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda. Preservice examination due to valve SI-873B replacement.
322900 246/27 VALVE SI-873B TO PIPE C-F-1 C5.30 NDEP-0201 PT PT-05-071 Sat 2080 HBR2-10618 SHT 112 Comment: Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda. Preservice examination due to valve SI-873B replacement 322725 246/42 PIPE TO COUPLING C-F-1 C5.30 NDEP-0201 PT PT-05-061 Sat 2080 HBR2-10618 SHT 112 Comment: Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda. Preservice examination due to valve Sl-873B replacement.
31 of 43 Pre-Service Examination Summary Summary Exam No. Component ID Component Description Category Item Procedure Method/Report  
#/Results System ISO Number Date 322775 246/43 COUPLING TO PIPE C-F-1 C5.30 NDEP-0201 PT PT-05-062 Sat 2080 HBR2-10618 SHT 112 9/29/2005 Comment: Examination was performed to the requirements of ASME Section Xi, 1995 Edition, thru 1996 Addenda. Preservice examination due to valve SI-8738 replacement.
322925 246/44 PIPE TO COUPLING C-F-1 C5.30 NDEP-0201 PT PT-05-063 Sat 2080 HBR2-10618 SHT 112 9/29/2005 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda. Preservice examination due to valve Sl-873B replacement.
322975 246/45 COUPLING TO PIPE C-F-1 C5.30 NDEP-0201 PT PT-05-064 Sat 2080 HBR2-10618 SHT 112 10/3/2005 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda. Preservice examination due to valve SI-873B replacement.
330400 247/32 PIPE TO VALVE SI.873A WELD C-F-1 C5.30 NDEP-0201 PT PT-05-072 Sat 2080 HBR2-10618 SHT 113 9/25/2005 Comment: Examination was performed to the requirements of ASME Section XI, 1995 Edition, thru 1996 Addenda. Preservice examination due to valve Sl-873A replacement.
330500 247/33 VALVE SIl873ATO PIPE C-F-1 C5.30 NDEP-0201 PT PT-05-073 Sat 2080 HBR2-10618 SHT 113 9/29/2005 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda. Preservice examination due to valve Sl-873A replacement.
330600 247/34 PIPE TO COUPLING C-F-1 C5.30 NDEP-0201 PT PT-05-074 Sat 2080 HBR2-10618 SHT 113 9/29/2005 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda. Preservice examination due to valve Sl-873A replacement.
330325 247/49 PIPE TO COUPLING C-F-1 C5.30 NDEP-0201 PT PT-05-065 Sat 2080 HBR2-10618 SHT 113 10/7/2005 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thru 1996 Addenda. Preservice examination due to valve Sl-873A replacement.
330375 247/50 COUPLING TO PIPE C-F-1 C5.30 NDEP-0201 PT PT-05-066 Sat 2080 HBR2-10618 SHT 113 9/29/2005 Comment: Examination was performed to the requirements of ASME Section Xl, 1995 Edition, thwu 1996 Addenda. Preservice examination due to valve Sl-873A replacement.
32 of 43 TAB F PRESSU RE TEST
 
==SUMMARY==
33 of 43 The table below lists the pressure tests performed from the close date of the previous NIS-1 (May 27, 2004) and the close of the First Period of the Fourth Ten Year Interval.SYSTEM DESCRIPTION COMPLETION PROCEDURE RESULTS DATE SFPC ISI Pressure Testing of Spent Fuel Cooling System 12/10/2004
*EST-084 SAT CVCS ISI Pressure Testing of Chemical and Volume Control System Outside Containment 1/14/2005
*EST-131 SAT SI Inservice Inspection Pressure Testing of SI Pump Discharge Piping 11/30/2004
*EST-078 SAT SW Inservice Inspection Pressure Testing of Service Water System 1/18/2005 EST-094 SAT AFW Inservice Inspection Pressure Testing of The Auxiliary Feedwater System 1/19/2005 EST-082 SAT CVCS inservice Inspection Pressure Testing of Chemical and Volume Control System 1/13/2005
*EST-093 SAT SI Inservice Inspection Pressure Testing of Spray additive Tank and Associated Piping 2/8/2005 *EST-092 SAT CCW ISI Pressure Testing of Component Cooling Water System Inside the Auxiliary Building 12/17/2004 EST-088 SAT FW ISI Pressure Testing of Feedwater System Outside Containment 12/2/2004 EST-077 SAT MS ISI Pressure Testing of Steam Supply to the SDAFW Pump 9/9/2004 EST-097 SAT EDGFO ISI Pressure Testing of Diesel Fuel Oil System 11/22/2004 EST-098 SAT*Includes Bolting Inspection on Borated Systems (invoked Code Case N-533-1)No deficiencies were noted for the above Engineering Surveillance Tests and all exceptions were addressed by the normal work request process and retained as permanent records, which may be obtained through the Progress Energy Carolinas, Inc., Document Control Services.34 of 43 The table below lists the pressure tests performed to date for the Second Period of the Fourth Ten Year Interval since the last NIS-1 submittal.
SYSTEM DESCRIPTION COMPLETION PROCEDURE RESULTS DATE CCW ISI Pressure Testing Of Component Cooling Water To CRD Cooler, RCP-A, B, 9/17/2005 EST-076 SAT And C, And Excess Letdown Heat Exchanger SW Inservice Inspection Pressure Testing Of Service Water Inside Containment To 9/17/2005 EST-081 SAT And From HVH Units 1 Through 4 Si Inservice Inspection Pressure Testing Of SI System and Containment Spray 9/14/2005
*EST-091 SAT Pump Suction Piping SG Inservice Inspection Pressure Testing Of The Steam Generator Secondary Side 9/17/2005 EST-128 SAT And Associated Class 2 Piping Si Inservice Inspection Pressure Testing Of The SIS Accumulators And Associated 9/17/2005
*EST-129 SAT Class 2 Piping Inside Containment RCS Inservice Inspection Pressure Retaining VT-2 Bolting Examination Of Reactor 9/21/2005
**EST-083-1 SAT Coolant System RCS Inservice Inspection Pressure Testing Of Reactor Coolant System 10/24/2005
**EST-083-2 SAT*Includes Bolting Inspection on Borated Systems (invoked Code Case N-533-1)** EST-083-1 is for bolted connections, EST-083-2 is for pressure testing at the end of the refueling outage.No deficiencies were noted for the above Engineering Surveillance Tests and all exceptions were addressed by the normal work request process and retained as permanent records, which may be obtained through the Progress Energy Carolinas, Inc., Document Control Services.35 of 43 TAB G EXAM I NATION PERCENTAGE
 
==SUMMARY==
36 of 43 CLASS 1
 
==SUMMARY==
TABLE TOTAL INTERVAL INTERVAL INTERVAL NUMBER SCHEDULED/COMPLETED CATEGORY NUMBER OF NUMBER NUMBER PERCENT 1ST 2 ND 3RD COMPONENTS REQUIRED COMPLETE COMPLETE PERIOD PERIOD PERIOD B-A* 2  20 20 0 0% 0/0 0/0 20/0 B-B1 13 5 1 20% 1/1 2/0 2/0 B-D* 36 23 3 13% 3/3 4/0 16/0 B-F 18 18 6 33% 4/4 4/2 10/0 B.G-1* 347 344 96 28% 48/48 48/48 248/0 B-G-2 45 45 21 46% 17/17 13/4 15/0 B-J 721 181 93 51% 64164 73/29 81/0 B-K 53 6 2 33% 2/2 2/0 2/0 B-L-1 9 3 0 0%0 0/0 0(0 3(0 B-L-2 3 0 0 0% 0/0 0/0 0/0 B-M-2 11 3 0 0% 0/0 0/0 0/0 B-N-I 1 1 0 0% 0/0 0/0 1/0 B-N-2 1 1 0 0% 0/0 0/0 1/0 B-N-3 1 1 0 0% 0/0 0/0 1/0 B-O2 56 5 1 20% 1/1 2/0 2/0 B-P 1 7 3 of 7 42% 2/2 3/1 2/0 B-Q 3 TECH SPEC N/A N/A N/A N/A N/A* Deferral Permissible
' Code Case N-598 invoked for this Category 2 Reactor Head Replaced in RO-23 37 of 43 CLASS 2
 
==SUMMARY==
TABLE TOTAL INTERVAL INTERVAL INTERVAL # SCHEDULED/COMPLETED CATEGORY NUMBER OF NUMBER NUMBER PERCENT 1ST 2 ND 3RD COMPONENTS REQUIRED COMPLETE COMPLETE PERIOD PERIOD PERIOD C-A 21 9 6 66% 3/3 3/3 3/0 C-B 26 10 5 50% 4/4 2/1 4/0 C-C 148 9 5 55% 3/3 4/2 2/0 C-D 1 1 0 0% 0/0 1/0 0/0 C-F-I 898 68 28 41% 24/241 26/4 35/0 C-F-2 141 28 15 53% 12/121 11/3 11/0 C-G 4 2 0 : 0 j / 0/0 210 C-H 11 011 (per period) j 14 of 33 42% 11/11 11/3 l 11/0 I Code Case N-598 invoked for this Category 38 of 43 CLASS 1, 2, & 3 SUPPORT
 
==SUMMARY==
TABLE TOTAL INTERVAL INTERVAL INTERVAL # SCHEDULED/COMPLETED CATEGORY NUMBER OF NUMBER NUMBER PERCENT 1ST 2ND 3RD COMPONENTS REQUIRED COMPLETE COMPLETE PERIOD PERIOD PERIOD F-A F1.101 207 52 27 51% 21/21 22/6 22/0 F-A, F1.201 385 58 30 51% 23/23 27/7 26/0 F-A, F1.301 556 56 29 51% 29/29 25/0 26/0 F-A, F1.401 92 Supports 66 23 34% 22/22 18/1 2610 on44 components l 1(23 Groups)' Code Case N-598 invoked for this Category 39 of 43 TAB H REPAIR AND REPLACEMENT 40 of 43 RO-23 REPAIR/REPLACEMENT
 
==SUMMARY==
REPORT NIS-2 # Work Order Component ID System Descri tion 04-034 338905 CVC-293C 2060 Replacing valve, piping and fitting 04-035 525362 CVC-277A 2060 Replacing valve and piping.04-036 510800 CVC-277C 2060 Replacing valve, piping and fitting 04-037 586766 CHG-PMP-C 2060 Replaced valve stop.04-038 483464 SW-374 4060 Replaced SW-374 with new valve 05-001 168081 01 Capscrew 2060 Replaced bolting on Boric Acid Filter due to boric acid accumulation/corrosion 05-002 618922 DG-B-LO-HTX 4060 Replaced Lube Oil HTX End Cover 05-003 597678 DG-A-LO-HTX 4060 Replaced Lube Oil Htx End Cover with spare 05-004 681666 8-AC-151R-61 7110 Repaired piping line 8-AC-151R-61 by welding 05-005 671221 FE-150 2060 Replaced bolting (studs and nuts) due to leakage 05-006 628658 EDG-A 4060 Alternate Cooling Water Supply & Discharge Modification 05-007 622493 EDG-I 4060 Alternate Cooling Water Supply & Discharge Modification 05-008 661742 BA-XFER-PMP-A 2060 Replaced 2 studs and nuts due to leakage.05-009 697587 HVH-8B 4060 Replaced threaded nipples 05-010 670842 HVH-8B 4060 Replaced cooling coil, piping, and fittings 05-011 768917 SI-870B 2080 Repalced valve disc 05-012 615770 SW-8 4060 Replaced valve 05-013 624261 SW-7 4060 Replaced valve 05-014 651737 SW-375 4060 Replaced Check Valve with rotating spare 05-015 189336 SW-377 4060 Replaced check valve with rotating spare 05-016 665455 AC-7-34/2 4080 Modified CCW system supports per EC 55731 05-017 648715 S6-1B 4060 Replaced inlet and outlet Strainer Flange bolting 05-018 759301 RC-525 2005 Replaced valve and piping 05-019 664068 SI-873A 2080 Replaced valve and pipe pieces 05-020 581883 LTDN-ORIFICE-A 2060 Replaced "A" Letdown restricting orifice 05-021 534701 CC-738 4060 Replacing valve 05-022 619151 Rx Head 2005 Replaced RVLIS and head vent piping and fittings 05-022 619146 1-RC-2501R-99 2005 Replaced RVLIS and Head Vent piping and fittings 05-023 558600 RPV Head 1005 Replaced RPV Head 05-024 564296 FI-660 4080 Modifying piping section and relocating FI-660 05-025 767472 213/F-WS 3020 Weld repair of restraint structure stiffener plate 05-026 662477 Snubber #20 2045 Replaced snubber 05-027 544849 FCV-478 3050 Replaced one stud and one nut damaged during maintenance 41 of 43 RO-23 REPAIR/REPLACEMENT
 
==SUMMARY==
REPORT NIS-2 # Work Order Component ID System Description 05-028 544818 MS-263A 3020 Replaced valve piston 05-029 664066 SI-873B 2080 Replaced valve and pipe pieces 05-030 633486 A & B CS Pump 2080 Modified A & B containment spray pump discharge piping 05-031 662682 Snubber #23 2060 Replaced snubber 05-032 703718 01 S/G A Manway 3005 Replaced bolts with studs/nuts to support temporary repair of mechanical connection 05-033 703718 05 S/G A Manway 3005 Replaced Manway cover, threaded inserts and machined Manway pad 05-034 703490 S/G A Manway 3005 Replacing studs and nuts installed with bolts 05-035 559034 FE-496 3050 Removed and re-welded tack welds for inspection 05-036 554808 FE-476 3050 Removed and re-welded tack welds for inspection 05-037 664191 Snubber#35 2060 Replaced snubber 42 of 43 ATTACHMENT I OWVNERS REPAIR I REPLACEMENT ACTIVITIES FORM N IS-2 43 of 43 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 I----- ---1. Owner PROGRESS ENERGY CAROLINAS, INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Date: 9/1012004 Sheet: I Of 2 Unit: 2 Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 ESR#:N/A EE:N/A WR/WO:338905 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A Address 4.5.Iticntiffu'Atinn nf 5Rvstpm- rlAInq,'r;4FMI~C.Al Ahnfln Vt IimF rC)ONTPOI qvq.Ti=2060 wwh W w va 1-.F 1 I ---- --- ---- -(a) Applicable Construction Code: B 31.1 Edition: 1986 Addenda:N/A Code Case:N/A Design Specification:
CPL-HBR2-M-019 (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N-416-2 Identification of ComoonentS Ranaired or Renlaced and Redlacement Comoonents 6.Name of Name of Manufacturer National Other Year Corected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)CVC-293C Edwards 8K447 NIA Valve 1971 Removed N CVC-293C Edwards N/A IN/A Valve (HT FOAC) 2004 Installed N Pipe Ebasco N/A IN/A Pipe 1971 Removed N Pipe Dubose N/A IN/A Pipe (HT 32789) 2004 Installed N Fitting Ebasco N/A N/A Elbow 1971 Removed N Fitting Energy & N/A N/A Elbow (HT KJ) 2004 Installed N Process Corp. .__ _ _ _ __ _ _ _ _ _ _ _ _ _ _7. Description of Work: Replacino valve, pipina and fittina 8. Test Conducted:
Hydrostatic I:] Pneumatic L-i Nominal Operating Pressure [J Exempt [-l Other IVT-21 Pressure LNOPI psig Test Temp. INOT1 OF 04-034 I V vp Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.Remarks: See WO 338905 turnover package Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate uthonzato
_ N/A Signed ISI ENGINEER Date 9/1312004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued try the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD, CONNECTICUT have inspected the components described in this Owner's Report during the period 31112004 to 9/13/2004 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASMIE Code, Section Xi.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_______Commissions NC 1507 Insector Signature National Board, State, Province, and Endorsements Date:9/1 3/2004 04 034.
1995 Edition 1996 Addenda APPENDIX It MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS, INC Name 411 FAYETTEVILLE ST., RALEIGH, NC 27602 Datae 9/24/2004 Sheet: 1 of 2 Address LA D 93f'tE3KIetrK1
: 2. P lAnt#Unit: 2.. ._Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 ESR#:N/A EE:N/A WRtWO:525362 CR;N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: Nt/A Authorization No.: N/A Expiration Date: NWA 4.5.Address Identification of System: Class:2 CHEMICAL AND VOLUME CONTROL SYSTEM 2060 (a) Applicable Construction Code: B 31.1 Edition: 1986 Addenda:N/A Code Case:N/A Design Specification:
CPL-HBR2-M-019 (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N-416-2 6. Identification of Components Hepaired or Replaced and He lacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or NO)CVC-277A Edwards 17ANE N/A Valve 2001 Removed N CVC-277A Edwards 22AVU N/A Valve (HT FOCA) 2004 Installed N Piping Maintenance N/A N/A Piping 2001 Removed N Piping Dubose N/A NIA Piping (HT 32789 2004 Installed N 7. Description of Work: Replacing valve and Dioir g.8. Test Conducted:
Hydrostatic E] Pneumatic
] Nominal Operating Pressure fX] Exempt [-3 Other [VT 21 Pressure INOP1 psig Test Temp. INOT1 &deg;F 04-035 Form NIS2 1995 E[dition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 525362 turnover Dpckac e Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp W/A Certificato.
_ N/A Signed 4 ISI ENGINEER Date 9/24/2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 3/412004 to 9/2412004 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
__ ______Commissions NC 1507 nspectsPrgnature National Board, State, Province, and Endorsements Date:9124/2004 04-035 I 0 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS, INC Name 411 FAYETTEVILLE ST.. RALEIGH, NC 27602 Address 2. Plant. H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS, INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 Date: 9/2412004 Sheet: 1 of 2 Unit: 2 ESR#:NIA EE:NIA WRIWO:510800 CR:N/A Repair Organization PO NoJob No;etc.Type Code Symbol Stamp: N/A Authorization No.: NIA Expiration Date: N/A Address Identification of System: Class:2 4.5.CHEMICAL AND VOLUME CONTROL SYSTEM 2060----_ ._. ,, _, ._, ..................
_ ._ _ _, ...............
_ _ .... _ _ _ ._ .................
_ _ _ _ _(a) Applicable Construction Code: B 31.1 Edition: 1986 Addenda:N/A Code Case Design Specification:
CPL-HBR2-M-419 (b) Applicable Edition of Section Xi Used for Flepair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N-416-2:N/A 6.Identification of Cnmnonnnts R~nairod or RenIlir-Ad and Ranlanamant CnmnnnAnt.a 0 Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)CVC-277C Edwards 08AFH N/A Valve 1998 Removed N CVC-277C Edward 48AYV N/A Valve (HT 2004 Installed N_ ___ SONO)Piping Maintenance N/A N/A Piping 1998 Removed N Piping Dubose N/A N/A Piping (HT 2004 Installed N__________________________32789)
_ _ _ _ _ _Fitting Maintenance N/A N/A Elbow 1998 Removed N Fitting E&P Corp. N/A N/A Elbow (HT KJ) 2004 Installed N 7. Description of Work: Replacing valve. Pioina and fittina 8. Test Conducted:
Hydrostatic
-1 Pneumatic Uj Nominal Operating Pressure LXJ Exempt [-3 Other [VT-21 Pressure [NOP1 psig Test Temp. [NOTl IF 04-036 S W I Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)Sheet dof 2e I 9. Remarks: See WO 510800 turnover packane Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp NWA Certificate O<tflyza o0 N/A Signed A -- ISI ENGINEER Date 9/24/2004 Owrer or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD, CONNECTICUT have inspected the components described in this Owner's Report during the period 2/24/2004 to 9/24/2004 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Date:9/24/2004 01 OA--, Commissions NC 1507 National Board, State, Province, and Endorsements 04-036 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Date: Q92412004 Sheet: 1 of 2 Address U D Qf%0)Kl.rfK
: 2. F 9I-nt 101~ Pk .J.f.,,I.J..U Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Unit: 2 ESR#:N/A EE:N/A WRWJO:586766 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: NWA Authorization No.: NWA Expiration Date: NMA Address 4.5.Identification of System: Class:2 CHEMICAL AND VOLUME CONTROL SYSTEM 2060 (a) Applicable ConstructionCode,:
B 31.1 Edition: 1986 Addenda:N/A Code Case:N/A Design Specification:
717319 (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A 6. Identification of Compoens Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)CHG-PMP-C Union N/A N/A Valve Stop 1996 Removed N CHG-PMP-C Union NA N/A Valve Stop 2004 Installed N 7. Description of Work: Redaced valve stop.8. Test Conducted:
Hydrostatic El Pneumatic I U Nominal Operating Pressure Ug Exempt l-l Other 1I Pressure [NOP] psig Test Temp. INOTI 0 F 04.037 9----
Form NIS2 1995 Edition 1996 Addenda SECTION Xl DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See 586766 turnover oackaae.Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate oI `o N/A Signed A 044.. ISI ENGINEER Date 924/2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NorLth Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 7/15/2004 to 9/24/2004 and state that to the best of my knowledge and belief, the Owner has pertormed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements od the ASME Code, Section Xl.By signing this certificate neomer the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising Irom or connected with this inspection.
0"10. (iX7L Comiss-ions NC' S157'- Ihspt~3s Sinaturo Date:"1412004 National Board, State, Province, and Endorsements 04-037 1995 Edition 1996 Addenda APPENDIX If MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS INC Name 411 FAYETTEVILLE ST., RALEIGH. NC 27602 Date: 12/712004_._. ...____Sheet: 1 Of 2 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Unit: 2 ESR#:NIA EE:N/A WRfWO:4483464 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: NIA Authorization No.: N/A Expiration Date: NIA Address Identification of System: Class:3 4.5.CICOX/If-W^AYTF OV4TrIA Araf%,- -- --, I -.---(a) Applicable Construction Code: B31.1 Edition: 1967 Addenda:N/A Code CasE Design Specification:
HBR-12053 (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: W1A~:N/A 6. Identification f Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer Nalional Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)SW-374 Crane N/A N/A Check Valve 1971 Removed N SW-374 Crane D2693 N/A Check Valve 2004 Installed N 7. Description of Work: Reolaced SW-374 with new valve 8. Test Conducted Hydrostatic j] Pneumatic L U Nominal Operating Pressure A)I Exempt l-l Other M-2] Pressure INOPP psig Test Temp. 1NOTQ OF 04-038 t Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)Sheet 2 of L 9. Remarks: See WO 483464 turnover package Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp NIA Certificatf at o N/A Signed 4 ISI ENGINEER Date 12/7/2004 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owners Report during the period 9/2712004 to 1217/2004 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
F P522 .i___ _ Commissions NC 1507 I Int ror's Stlature National Board, State, Province, and Endorsements Date:1217/2004 04-038 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Cede Section Xl Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Date:-21412005 Sheet: t of 2 Unit: 2 Name 3581 WEST Entrance RD; HARTSVILLE, SC 295550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 ESR#:NIA EE:N/A WRNWO:168081 01 CR:NIA Repair Organization PO No;Job No:etc.Type Code Symbol Stamp: N/A Authorization No.: NWA Expiration Date: N/A Address Identification of System: Class:2 I 4.5.C:HEMICAL AND VOLUME CONTROL SYSTEM 2060----_, _ _ ._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _(a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:NlA Code Case Design Specification:
CPL-XXXX-M-001 (b) Applicable Edition o Section Xl Used for Repair/Replacement Activity:
1995 Edition l9 Addenda Code Case: NWA;:N/A R Idrpntiffiratinn nf Crnmrwnn~nt-Ranairerl nr R~nlnpzrn sandi Ranlainamant (romnnnant-q Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)Capscrew Maintenance N/A N/A Boric-Acid-FLT 1998 Removed N__ Bolting Capscrew HC Warner NA N/A Boric-Acid-FLT 2004 Installed N Bolting Nut Maintenance N/A NIA Boric-Acid-FLT 1998 Removed N__ _ ,Bolting Nut Nova N/A N/A Boric-Acid-FLT 2004 Installed N Bolting 7. Description of Work: Replaced bolting on Boric Acid Filter due to boric acid accumulation/corrosion
: 8. Test Conducted:
Hydrostatic U Pneumatic LI Nominal Operating Pressure fj Exempt pXq Other U Pressure [WAI psig Test Temp. INWA1 0 F 05.001 S Form NIS2 1995 Edition 1996 Addenda SECTION Xl DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See 168081 01 turnover package.Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate N/A Signed T4L 1 A : .(- ISI ENGINEER Date 2y4e200 Owner or Owner's Designee, Title CERTIFICATE!
OF INSERVICE INSPECTION
: 1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 916/2003 to 24/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl By signing this certificate neither the Inspector or his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
________Commissions NC 1507 rp s Signature National Board, State, Province, and Endorsements Date:214/2005 0-001 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS, INC Name 411 FAYETTEVILLE ST., RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SO 29550 Date: 612212005 Sheet: 1 of 2 Unit: 2 EC#:N/A EE:NIA WR/WO:61 8922 CR:N/A Repair Organization PO No:Job No;etc.Type Code Symbol Stamp: NIA Authorization No.: NIA Expiration Date: NIA 4.5.Address Identification of System: Class:3 SERVICE WATER SYSTEM 4060 (a) Applicable Construction Code: 831.1 Edition 1967 Addenda:N/A Code Case:N/A Design Specification:
729-063-16 (b) Applicable Edition of Section XI Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A Identification of Comoonents Reoaired or Reolaced and Reolacement Comoonents 6.Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built removed, or Code Installed Stamp (Yes or No)DG-B-LO-HTX Fairbanks Morse N/A N/A HTX End Cover 1971 Removed N DG-B-LO-HTX Fairbanks Morse N/A N/A HTX End Cover 2005 Installed N 7.8.Description of Work: Replaced Lube Oil HTX End Cover Test Conducted:
Hydrostatic U1 Pneumatic L] Nominal Operating Pressure UX Exempt [-l Other jVT-1 Pressure [NOPj psig Test Temp. [NOT]&deg; F 05-002 9 Form NIS2 1995 Edition 1996 Addenda SECrION Xl DIVISION 1 FORM NIS-2 (Back)Mk Sheet 2 of 2.9. Remarks: See WO 618922 turnover packaoe Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate ojctf o. N/A Signed 4 .ISI ENGINEER Date 61212005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 2/712005 to 6/22/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASIVIE Code, Section Xl.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Kdln sQ,____ Commissions NC 1507 Inspecs Siaure National Board, State, Province, and Endorsements Date:6/2212005 05-002 S 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRtREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS2 1. Owner PROGRESS ENERGY CAROUNAS INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 nnt.-.&rsn"fVs vx Sheet: 1 of 2 Address 14 R DfVI0et'nK
: 2. P Zlfin#Unit: 2I Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 EC#:N/A EE:N/A WRIWO:597678 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp::N/A Authorization No.: N/A Expiration Date: N/A Address Identification of System: Class:3 4.5.RlFIX/r'C:.
WAT170 RYRTFMK Afn-1 (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Cast Design Specification:
729-063-16 (b) Applicable Edition of Section Xi Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A):N/A 6 fidantifir~tinn
^f (~nmra~nuntk Ra~nsiraud mr Rcrnisked jnn.1 Ranlw~anpnt Cr~jnnnnc~ntr, Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built lRemoved, or Code Installed Stamp (Yes or No)DG-A-LO-HTX Fairbanks Morse N/A N/A HTX End Cover 1971 Removed N DG-A-LO-HTX Fairbanks Morse N/A N/A HTX End Cover 2005 Installed N 7. Description of Work: Rerdaced Lube Oil Htx Erd Cover with snare 8. Test Conducted Hydrostatic LUj Pneumatic U ] Nominal Operating Pressure 2g Exempt f-]Other [T-21 Pressure INOPI psig Test Temp. lNOTi &deg;F 05-003 Form NIS2 1995 Edition 1996 Addenda SECTION Xl DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See 597678 turnover package Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Cenificti0Me io. NIA Signed 16 ISI ENGINEER Date 6120/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described In this Owneres Report during the period 2/4/2005 to 6/2012005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
7______Commissions NC 1507 Inspe s Sig e National Board, State, Province, and Endorsements Date:6/20/2005
.5.03 e 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3SS1 WEST ENTRANCE RD: HARTSVILLE SC 29550 Date: 6/20/2005 Sheet: 1 of 2 Unit 2 ,. L EC#:60405 EE:N/A WR/WO:681666 CR:t52423 Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A___- -._ .___.___ __ -_-4.5.Address Identification of System: Class:3 SPENT FUEL PIT COOLING SYSTEM 7110 (a) Applicable Construction Code: B31.1 Edition: 1967 Addenda:N/A Code Case:N/A Design Specification:
CPL-HBR2-M-048 (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N-416-2 Identification of Comoonents Renaired or Renlaced and Rnelacement Comnonents 6.Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. I3oard No. Identification Built Removed, or Code Installed Stamp (Yes or No)8-AC-15IR-61 Ebasco N/A N/A Pipe 1971 Corrected N 7.8.Description of Work: Repaired Diping line 8-AC-151R-61 by weldina Test Conducted:
Hydrostatic UL Pneumatic 1.] Nominal Operating Pressure PQ Exempt [-I Other IVT-2 Pressure [NOPM psig Test Temp. INOT] IF 05-004 Form NIS2 1995 Edition 1996 Addenda SECTION Xl DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 681666 turnover Package Applicable Mantuacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certfia!N o N/A Signed 4 G o L.C Q ISI ENGINEER Date 6/20/2005 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD, CONNECTICUT have inspected the components described in this Owner's Report during the period 3/3/2005 to 6120/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASMIE Code, Section Xi.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
________Commissions NC 1507 ns National Board, State, Province, and Endorsements Date:6/2012005 05004 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 1111111=1 1. Owner PROGRESS ENERGY CAROLINAS.
INC-Q.v.Name 411 FAYETTEVILLE ST.. RALEIGH- NC 27602 Sheet: 1 of 2....... ............
_ _ ___ Y ..........
a__. _ .........
_ _ .____Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Unit: 2 EC#:N/A EE:NIA WRIWO:671221 CR:NIA Repair Organization PO No;Job No;etc.Type Code Symbol Stanp. N/A Authorization No.: N/A Expiration Date: N/A Address Identification of System: Class:2 4.5.rfLWrChAt'A1 Akin Ini[ I IMFA 1r.%iT~nl QVQTFkA OrnA 2:V ---.- .-.-11, (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case Design Specification:
CPL-XXXX-M-001 (b) Applicable Edition of Section Xi Used for Repair/Replacement Activity+.
1995 Edition 1996 Addenda Code Case: N/A):N/A 6. Identiication of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identirication Built Removed, or Code Installed Stamp (Yes or No)FE-150 Maintenance N/A N/A Studs 1998 Removed N FE-150 Mackson NIA N/A Studs 2005 Installed N FE-150 Maintenance N/A N/A Nuts 1998 Removed N FE-150 Mackson N/A N/A Nuts 2005 Installed N 7. Description of Work: Replaced BoIting (Studs and Nuts) due to leakage 8. Test Conducted:
Hydrostatic El Pneumatic L U Nominal Operating Pressure I U Exempt [XI Other [ Pressure [A psig Test Temp. [N/Al OF 05-005 Form NIS2 1995 Edition 1996 Addenda SECTION XI DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 671221 turnover package Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code. Section Xl.Type Code Symbol Stamp N/A Certificate ofv No. N/A Signed 4 ISI ENGINEER Date 6/2212005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD, CONNECTICUT have inspected the components described in this Owner's Report during the period 3/28/2005 to 6/22/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
-_v __'_ _ Commissions NC 1507 ins " gnature National Board, State, Province, and Endorsements Date:6/2212005 05-005 I
-;-wX7 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH, NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD; HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Date: 824/2005 Sheet: 1 of 2 Unit, 2 EC#:59019 EE:NIA WR/WO:628658 CR:167663 Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: NIA Authorization No.: N/A Expiration Date: NIA Address Identification of System: Class:3 4.5.iFR'IN WATR CVCT=IR Anon-- .. I I ----11.(a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case Design Specification:
See EC 59019 (b) Applicable Edition of Section XI Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N-416-2 e:N/A 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Corrected.
ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)EDG-A Fairbanks Morse N/A N/A Jacket Water 1971 Removed N HTX Covers 4-CW-488 Maintenance N/A N/A Alt. Cooling 2005 Installed N Piping EDG-A Fairbanks Morse N/A N/A After Coolant 1971 Removed N HTX Covers 6-CW-487 Maintenance NIA NIA Alt. Cooling 2005 Installed N Piping 7. Description of Work: Alternate Cooling Water SuOplV & Discharge Modification
: 8. Test Conducted:
Hydrostatic 1.U Pneumatic L:] Nominal Operating Pressure f:J Exempt l-l Other IVT2/@3 Pressure [NOPI psig Test Temp. INOT] 0 F 05-006 Form NIS2 1995 Edition 1996 Addenda SECTION XI DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 628658 turnover Dackage Applicable Manutacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certifiat No. N/A Signed ISI ENGINEER Date 8/2412005 Owner or Owners Designee, Tite CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina end employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 12/612004 to 8/24/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
____ LCommissions NC 1507 Ines sigriture National Board, State, Province, and Endorsements Date:8/2412005 05-006 k 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST., RALEIGH, NC 2760'2 Date: 8/24/2005 Sheet: 1 of 2 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
'SC 29550 Unit: 2 EC#:59017 EE:NIA WR/WO:622493 CR:167663 Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: NIA Expiration Date: N/A TFM 406r0 Address Identification of System: Class:3 4.5.SFRVICF WATFR RYS (a) Applicable Construction Code. B 31.1 Edition: 1967 Addenda:N/A Code Case Design Specification:
See EC 59017 (b) Applicable Edition of Section Xi Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N-416-2 i:N/A 6. Identification of Cornponents Repaired or Re -aced and Re lacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)EDG-B Fairbanks Morse N/A N/A Jacket Water 1971 Removed N._ HTX Covers 4-CW-486 Maintenance N/A N/A Alt. Cooling 2005 Installed N Piping EDG-B Fairbanks Morse N/A N/A After Coolant 1971 Removed N HTX Covers 6-CW-460 Maintenance N/A N/A Alt. Cooling 2005 Installed N___ __ __ __ _ _ __ __ __ _ , P iping __ _ _ _ _ __ _ _ _7. Description of Work: Alternate Cooling Water Supply & Discharge Modification
: 8. Test Conducted:
Hydrostatic L-] Pneumatic U Nominal Operating Pressure 1 Exempt l-l Other EVT-?J3 Pressure INOPJ psig Test Temp. INO1 'F 05-007 Form NIS2 1995 Edition 1996 Addenda SECTION Xl DIVISION 1 FORM NIS-2 (Back)Sheet 2 of .2.9. Remarks: See WO 622493 turnover packaae Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A CertificateLAuatezbion No. N/A Signed A = ISI ENGINEER Date 8/24/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described In this Owner's Report during the period 1218/2004 to 824/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
A_______ Commissions NC 1507 Ins Signature National Board, State, Province, and Endorsements Date:8/2412005 05-007 LS-1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRPREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 Date: 6/30/2005 Sheet: 1 of 2 Unit: 2 EC#:N/A EE:NIA WR/WO:661742 CR:147748 Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A Address Identification of System: Class:2 4.5.CHEMICAL AND VOLUME CONTROL SYSTEM 2060----_ ._ _ _ _ _ _ _ _ _ _ _ _(a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case Design Specification:
CPL-XXXX-M-001 (b) Applicable Edition of Section Xl Used for lepair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A e:N/A 6.Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)BA-XFER- Maintenance UA N/A Discharge Flange 1998 Removed N PMP-A Bolting BA-XFER- Mackson N/A N/A Discharge Flange 2005 Installed N PMP-A Studs BA-XFER- Anchor Darling N/A NA Discharge Flange 2005 Installed N PMP-A Nuts-.= __________________
: 7. Description of Work: Replaced 2 studs and nuts due to leakage.B. Test Conducted:
Hydrostatic 1-1 Pneumatic 1j Nominal Operating Pressure LJ Exempt [-I Other [M-1 I Pressure IN/Al psig Test Temp. IN/l I F 05-008
.I Form NIS2 1995 Edition 1996 Addenda SECTION Xl DIVISION I FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 661742 turnover packaae Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate oftoil No. M/A Signed_ ISI ENGINEER Date 6130/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION
: 1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described In this Owner's Report during the period 3/28/2005 to 6130/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements od the ASME Code, Section Xl._ By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
ths ip ( Commissions NC 1507)Insrs7 nature National Board, State, Province, and Endorsements Date:6/30/2005 05-008 e 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS, INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Date: 1014/2005 Sheet: 1 of 2 Unit: 2 Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 EC#:N/A EEMA WRIWO:697587 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A Address Identification of System: Class:3 i 4.5.SERVICE WATER SYSTEM 4060 (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case Design Specification:
N/A (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: NIA rN/A 6. Identification of ComponentS Repaired or Repaced and Re lacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. l3oard No. Identification Built Removed, or Code Installed Stamp (Yes or No)HVH-8B Maintenance N/A N/A Inlet flange nipple 1997 Removed N HVH-8B Maintenance N/A NIA Inlet flange nipple 2005 Installed N 7. Description of Work: Redlaced threaded niopl s 8. Test Conducted.
Hydrostatic IU Pneumatic Uj Nominal Operating Pressure mJ Exempt [-H Other IT-21 Pressure INOPi psig Test Temp. fNOr, 'F 05-009 Form NIS2 1995 Edition 1996 Addenda SECTION Xl DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 697587 turnover packace.Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate t No. N/A Signed ISI ENGINEER Date 10/4/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION
: 1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 4/1/2005 to 10/4/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in arny manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_______Commissions NC 1507 nrsC sp ib e National Board, State, Province, and Endorsements Date:1 0/4/2005 05-009 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the? Provisions of the ASME Code Section Xi Form NIS 2 0 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 2760: Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Date: 10/4/2005 Sheet: 1 of 2 Unit: EC#:60189 EE:N/A WR/WO:670642 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A Address Identification of System: Class:3 4.5.SERVICE WATER SYSTEM 4060 (a) Applicable Construction Code: B31.1 Edition: 1967 Addenda:N/A Code Case.Design Specification: (b) Applicable Edition of Section Xi Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N-416-2 Identification of Comronents Reoaired or Renlaced and Realacement Comoonents
:N/A 6.Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)HVH-BB H. K. Porter Co N/A N/A Cooling Coil 1997 Removed N HVH-8B Mario 038006 NIA Cooling Coil 2005 Installed N 1 1/2-CW-399 Maintenance N/A N Piping 1971 Removed N 1 1/2-CW-399 Maintenance N/A N Piping 2005 Installed N 1 1/2-CW-400 Maintenance N/A N Piping 1971 Removed N 1 1/2-CW-400 Maintenance N/A N Piping 2005 Installed N.J , , _ I _ _ _ =====7. Description of Work: Replaced cooling coil. piiina., and fittinos 8. Test Conducted:
Hydrostatic E Pneumatic U. Nominal Operating Pressure LM Exempt I-)Other IVTI21 Pressure rNOPI psig Test Temp. [NOT) OF 05-010 Form NIS2 1995 Edition 1996 Addenda SECTION XI DIVISION 1 FORM NIS-2 (Back)0 Sheet 2 of 2.9. Remarks: See WO 670842 turnover packace.Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correcd and this conforms to the requirements of the ASME Code. Section XI.Type Code Symbol Stamp N/A Certificate cuuenzao F A N/A Signed -4 %A -IRI ENG.INEER Date two5j Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 7/13/2005 to 10/4/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury cr property damage or a loss of any kind arising from or connected with this inspection.
'Inspet i% wre-Commissions NC 1507 National Board, State, Province, and Endorsements Date:10/4/2005 05"010 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS, INC Name AlI FAYFTTFVIII F ST. RAI FIGH.M NC 276029 Dnate: 1 01/200fl5 cow.1- --YE--Y Sheet: 1 Of 2....... --... ... .--Address SI = nMIblf.NKI
: 2. F fot-U29 IL Name 3581 WEST Entrance RD.: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 Address Unit: 2 EC#:N/A EE:N/A WRMO.:768917 CR:N/A Repair Organizatlon PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A 4.5.Identification of System: Class:2 'SAFFTY IN.JFC1TION SYSTFM 2080 (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code CasE Design Specification:
N/A (b) Applicable Edition of Section XI Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A i:N/A 6.Identification of Comoonents Reoaired or Replaced and Reolacement Comoonents Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Buii Removed, or Code Installed Stamp (Yes or No)SI-870B Anchor Darling N/A N/A Valve Disc 1971 Removed N SI-870B Anchor Darling N/A N/A Valve Disc 2005 Installed N 7. Description of Work: Replaced valve disc 8. Test Conducted:
Hydrostatic I I Pneumatic L U Nominal Operating Pressure U-) Exempt [XJ Other U. Pressure f[/4 psig Test Temp. IN/Al OF 05-011 1 Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 9 FORM NIS-2 (Back).Sheet 2 of 2.9. Remarks: See WO 768917 turnover Dackaoe Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate 0LA"flhrztr+c4o NtA Signed J ISI ENGINEER Date 10/17/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 10/82005 to 10/17/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
_) -l b s Commissions NC 1507 National Board, State, Province, and Endorsements Date: 1 0/1 7/2005 05411 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the! Provisions of the ASME Code Section Xi OForm NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Date: 10/18/2005 Sheet: 1 of 2 Unit: 2 EC#:N/A EE:N/A WR/WO:61 5770 CR:NIA Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: NWA_ .., .. , .._ .-0 Address 4. Identification of System: Class:3 SERVICE WATER SYSTEM 4060 5. (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case:NfA Design Specification: (b) Applicable Edition of Section Xi Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or NO)SW-8 Allis Chalmers N/A N/A Butterfly Valve 1971 Removed N SW-8 Allis Chalmers 01 N/A Butterfly Valve 2005 Installed N 7.8.Description of Work: Replaced valve Test Conducted:
Hydrostatic E Pneumatic L-] Nominal Operating Pressure fJ Exempt [1-Other IVT-21 Pressure INOPI psig Test Temp. INOT! OF 05-012 I Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 615770 turnover packaoe.Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code. Section XI.Type Code Symbol Stamp N/A Certfficate pfAvVlz_ No. N/A Signed A 4 ISI ENGINEER Date 10/18/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 9/12/2005 to 10118/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements cf the ASME Code, Section Xi.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
________Commissions NC 1507 Inspect National Board, State, Province, and Endorsements Date:10/18/2005 05-012 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS, !NC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 Date: 10/18/2005 Sheet: 1 of 2 Unit:_FC#:NJA 2 FF4JJA An .vrr _ _ _wawn-;oso;:r fnI&IIA VWVW .'.:4i1 Ml.rm Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: NWA Address 4. Identification of System: Class:3 SERVICE WATER SYSTEM 4060 5. (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case:NIA Design Specification: (b) Applicable Edition of Section XI Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A 6. IdentIfication of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)SW-7 Allis Chalmers N/A N/A Butterfly Valve 1971 Removed N SW-7 Allis Chalmers 01 N/A Butterfly Valve 2005 Installed N 7.8.Description of Work: Replaced valve Test Conducted:
Hydrostatic U 1 Pneumatic U 1 Nominal Operating Pressure [g Exempt [-l Other IVT-21 Pressure [NOPi psig Test Temp. INOTI *F 05-013 Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION I FC)RM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 624261 turnover packace Applicable Manufacturers Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificatfato No. NIA Signed I iSI ENGINEER Date 10/18/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 9/13/2005 to 1011812005 and state that to the best of my knowledge and belief. the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
(_2.__ Commissions NC 1507 Inspect3S ature National Board, State, Province, and Endorsements Date:10/1812005 05-013 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi* Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 no -*4^114 0stnnnc LU'al. I U? I UofUU.J Sheet: 1 of 2 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC .9550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Unit: 2 EC#:N/A EE:N/A WRMWO:651 737 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: NIA Authorization No.: NIA Expiration Date: NIA Address 4. Identification of System: Class:3 SERVICE WATER SYSTEM 4060 5. (a) ApplicableConstructionCode:
B 31.1 Edition. 1967 Addenda:N/A Code Case N/A Design Specification: (b) Applicable Edition of Section Xi Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A 6. Identification of Components Repaired or Reolaced and Replacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identifcation Built Removed, or Code installed Stamp (Yes or NO)SW-375 Crane N/A N/A Check Valve 1971 Removed N SW-375 Crane N/A N/A Check Valve 1971 Installed N 7.8.Description of Work: Replaced Check Valve with rotating spare Test Conducted:
Hydrostatic U Pneumatic U. Nominal Operating Pressure LXJ Exempt [-]Other [IVT-21 Pressure INOP! psig Test Temp. INOTI 'F 05-014 Form NIS2 1995 Edition 1996 Addenda SECTION Xl DIVISION 1 FORM NIS-2 (Back)* Sheet 2 of 2.9. Remarks: See W0651737 turnover packaae. Replacement valve previously at SW-374 location (ref WO 483464)Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correcit and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate9LAueiftie o.a N/A Signed ISI ENGINEER Date 10/1812005 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components descnbed in this Owners Report during the period 10/10/2005 to 10/18/2005 and state that to the best of my knowledge and belief, the Owner has peiformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements cf the ASME Code. Section Xl.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
__________Commissions NC 1507 nspec sr re National Board, State. Province, and Endorsements Date:10/18/2005 05-014 1995 Edition 1996 Addenda i APPENDIX II MANDATORY FORM NIS-2 OWNER S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI Form NIS 2 I 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 2760:2 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 Date: 10/18/2005
----------
Sheet: 1 Of 2 Unit: 2 EC#:N/A EE:NJA WRNVO:189336 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A Address Identification of System: Class:3 4.5.9;ERVICE WATER SYSTEM 4060 (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case Design Specification:
HBR2-12053 (b) Applicable Erition ot Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: NIA:NIA It 6. Identicaton o Coponents Repaired or Replaced and He l a 2 cement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identiication Buil Removed, or Code Installed Stamp (Yes or No)SW-377 Crane N/A NWA Check Valve 1971 Removed N SW-377 Crane N/A N/A Check Valve 1971 Installed N 7. Description of Work: Reolaced check valve with rotating spare 8. Test Conducted:
Hydrostatic 1j Pneumatic IzJ Nominal Operating Pressure [XJ Exempt 1-]Other rVT-21 Pressure fNOP1 psig Test Temp. [NOT] &deg;F 05-015 Form NIS2 1995 Edition 1996 Addenda SECTION Xl DIVISION 1 .FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 189336 turnover cackape. Reeplacement valve oreviouslv at SW-375 location (ref WO 651737)Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp NIA Certificate
&As= 0o. N/A Signed ISI ENGINEER Date 10/1812005 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 9/14/2005 to 10/18/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be flable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
__ __ Commissions NC 1507 lnspect P*atur, National Board, State. Province, and Endorsemnets Date:10/18/2005 05-015 V 1995 Edition 1996 Addenda 0 APPENDIX II MANDATORY FORM NIS-2 OWNER'S R:EPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH, NC 27602 Date: 10/22/2005 Sheet: 1 of 4 Address Li R 3lRoIMOIkPd
: 2. P 1-4,n-lal f ,tn~ ~ _Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, 'C 29550 Unit: 2 EC#:55731 EE:NIA WRIWO:665455 CR:11 1506 Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authnz7atinn No.: MIA Expiration Date: N/A Address 1rla-CM-r-in -f C0-4m ^I- c 4.f'VNILACL"NKMM1, (VfI IKIIt WAY=TFD OVC TFI A u"ilvi~vr Ul--sen.bascv~~~
I .. II~ VV W I cn I I -- CM v 5. (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case:N/A Design Specification:
GID/R87038/0003 (b) Applicable Edition of Section XI Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A 6. tdentification of Components Repaired or ReF acet and Replacement Com ents -Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identificatbon Buit Removed, or Code Installed Stamp (Yes or No)AC-7-34/2 Ebasco N/A N/A Support 1971 Corrected N AC-7-38/16B Ebasco N/A N/A Restraint 1971 Corrected N AC-8-35/7 Ebasco NWA NIA Restraint 1971 Corrected N AC-8-35/23 Ebasco N/A N/A Restraint 1971 Corrected N AC-8-35/24 Ebasco NA N/A Restraint 1971 Corrected N AC-7-38B Ebasco N/A N/A Restraint 1971 Corrected N.I _ .S ---- -, -7. Description of Work: Modified CCW system suicorts per EC 55731 8. Test Conducted:
Hydrostatic LU Pneumatic L-U Nominal Operating Pressure 'LI Exempt fXJ Other JVT-31 Pressure IN/Al psig Test Temp. [N/Al &deg;F 05-016 1995 Edition 1996 Addenda 0~APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by tho Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS, INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Date: I 10010mr5.w vs--^avvz Sheet: 2 of 4 Unit: 2 EC#:55731 EE:N/A WR/WO:665455 CR:1115 06 Repair OrganIzation PO No;Job No;etc.Type Code Symbol Stamp: NIA Authorization No.: NJA Expiration Date: N/A 4.5.Address Identification of System: Class:2 C OMPONENT COOLING WATER SYSTEM 4080 (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case:N/A Design Specification:
GID/R87038/0003 (b) Applicable Edition of Section Xi Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: NIA 0 6. Identification of Comrnents Repaired or Replaced and Re lacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Seral No. Board No. Identification Built Renmoed, or Code Installed Stamp (Yes or No)AC-8-H4 Ebasco N/A NIA Support 1971 Corrected N AC-8-35122 Ebasco N/A N/A Restraint 1971 Corrected N AC-7-3714 Ebasco N/A N/A Restraint 1971 Corrected N AC-7-3 Ebasco N/A N/A Restraint 1971 Corrected N AC-7-38J5J Ebasco NIA N/A Restraint 1971 Corrected N AC-9-H15 Ebasco N/A NIA Support 1971 Corrected N AC-9-H18 Ebasco N/A NIA Restraint 1971 Corrected N AC-8-35110 Ebasco N/A N/A Restraint 1971 Removed N AC-8-35/4 Ebasco N/A NIA Restraint 1971 Removed N AC4-35/3 Ebasco N/A N/A Restraint 1971 Removed N 7. Description of Work: Modified CCW system supports oer EC 55731 8. Test Conducted:
Hydrostatic U Pneumatic 1U. Nominal Operating Pressure Uj Exempt [XI Other Dg.3] Pressure IN/A1 psig Test Temp. INIA) &deg;F 05-016 9 1995 Edition 1996 Addenda.APPENDIX li MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by tho Provisions of the ASME Code Section XI Form NiS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON n%.#.-inio)9ftw; VQ rasu. w -Sheet: 3 of 4 Unit: 2 Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 EC#:55731 EE:NIA WRIWO:665455 CR:1111506 Repair Organization PO No;Job No;etc.Type Code Symbol Stamp. N/A Authorizatinn Nno. NIA_: _ .-:-Expiration Date: N/A Address Identification of System: Class:2 4.5.(,OMPONENT COOLING WATER SYSTEM 4080_ ._ .... _ ._ .._ _ _ _ ... _ ... .. _ .. _ ._ .= ... ._ _(a) Applicable Construction Code: B_31.1 Edition: 1967 Addenda:N/A Code Cas4 Design Specification:
GID1R87038/0003 (b) Applicable Edition of Section XI Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A;:N/A 6. Identification or conponents Hepaired or R aced and R acement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)AC-9-36/7 Ebasco N/A N/A Support 1971 Removed N AC-7-37/1 1J Ebasco N/A N/A Restraint 1971 Removed N AC-8-35/25 Ebasco N/A N/A Support 1971 Removed N AC-8-343 Ebasco N/A N/A Restraint 1971 Removed N AC-8-H10 Ebasco NIA N/A Support 1971 Removed N AC-9-38Ff7 Ebasco N/A N/A Restraint 1971 Removed N AC-9-38F/H4 Ebasco N/A N/A Restraint 1971 Removed N AC-7-H15 Ebasco NIA N/A Restraint 1971 Removed N AC-7-H2 Ebasco N/A N/A Restraint 1971 Removed N AC-8-H11 Ebasco NIA N/A Support 1971 Removed N 7. Description of Work: Modified CCW system s ineorts per EC 55731 8. Test Conducted:
Hydrostatic LI. Pneumatic fjj Nominal Operating Pressure U Exempt [XI Other IT-31 Pressure [ /Al psig Test Temp. IN[Al &deg;F 05-016 Form NIS2 1995 Edition 1996 Addenda SECTION XI DIVISION 1 t FORM NIS-2 (Back)Sheet 4 of 4.9. Remarks: See WO 665455 and EC55731 turnover oackaaes Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correc: and this conforms to he requirements of fee ASME Code, Section XI.Type Code Symbol Stamp N/A Certific ata No. N N/A Signed 4 ISI ENGINEER Date 10/22/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina end employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owners Report during the period 5/13/2005 to 10/22/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
this inseCommissions NC 1507 Inspect s Spature National Board, State, Province, and Endorsements Date:10/2212005 05.016 Form NIS 2 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant HKB.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 35R1 WFST ENTRANCE RD, HARTSVILLF SC 29S50 n~i.-.I r0snrs Baby. w Woof two Sheet: 1 Of 2 Unit: 2 EC#:62401 EE:NIA WR/WO:648715 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A-- -----Address 4. Identification of System: Class:3 SERVICE WATER SYSTEM 4060 5. (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case:N/A Design Specification:
CPL-XXXX-M-001 (b) Applicable Edition of Section XI Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: NIA 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or NO)S641B Maintenance N/A N/A Strainer bolting 1971 Removed N S6-1B Mackson N/A N/A Strainer bolting 2005 Installed N__a _______________
a ________________
________ a _____________
7.8.Description of Work: Replaced inlet and outlet Strainer Flange bolting Test Conducted:
Hydrostatic L I Pneumatic I) Nominal Operating Pressure L-] Exempt l-l Other [1 Pressure f.W1 psig Test Temp. IN/Al OF 05-017 Form NIS2 1995 Edition 1996 Addenda SECTION Xl DIVISION 1 FORM NIS-2 (Back)Sheet 2 of L 9. Remarks: See WO 648715 turnover packaae Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate f No. N/A Signed S181 ENGINEER Date 10123/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described In this Owner's Report during the period 1011/2005 to 10/23/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
(217_____
_ Commissions NC 1507 lsp6g nature National Board, State, Province, and Endorsements Date:10/23/2005 05-017 FormNIS 2 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM MS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As ReqWired by tht? Provisions of the ASME Code Section XI I ---1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYElTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
'C 29550 Dat ta Ini"laonfW W.
* vl -cvw Sheet: 1 of 2 Unit: 2 EC#:N/A EE:N/A WR!WO:759301 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A Address Identification of System: Class:1 I 4.5.FIEACTOR COOLANT SYSTEM 2005 (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case Design Specification:
CPL-HBR2-M-048 (b) Appicable Edition of Section Xl Used for Repair/Replacement Activity 1995 EditIon 1996 Addenda Code Case: N-416-2 eN/A 6.Identification of Comoonents Renaired or Reolaced and Renlacement Comnonents Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Idertification Buift Removed, or Code Installed Stamp (Yes or No)RC-525 Edwards N/A N/A Globe valve 2004 Removed N RC-525 Edwards N/A N/A Globe valve 2005 Installed N Piping Dubose N/A N/A 3/4'-RC-28A 2004 Removed N Piping Dubose N/A NIA 3/4--RC-28A 2005 Installed N I I 4 I.7. Description of Work: Replaced valve and piping 8. Test Conducted:
Hydrostatic
[1d Pneumatic U Nominal Operating Pressure IX] Exempt (-J Other IVT-21 Pressure [NOPl psig Test Temp. [NOT! F 05-018 Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 697587 turnover packaoe Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certifilal No. NIA Sigred A ISI ENGINEER Date 0 0 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 9/23/2005 to 10/24/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
________Commissions NC 1507 S?6alu e National Board, State, Province, and Endorsements Date:10/2412005 0-01 8 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC .9550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 na4-4 flrI'flA 3.'-L,.. EwaLk.Sheet: 1 Of 2 Unit: 2 EC#:N/A EE:N/A WRIWO:664068 CR:NtA Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorizaton No.: N/A Expiration Date: NtA Address Identification of System: Class:2 4.S.CACL-rV IKI Or'TlKI 0V0TFrU oN'tar 0-1 .. I IWI. I %11. -...(a) Applicable Construction Code: B 31.1 Edition: 1967 AddendaN/A Code Case Design Specification:
CPL-HBR2-M-048 (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity.
1995 Edition 1996 Addenda Code Case: N-416-2 e:NlA 6. Identification of Components Repaired or Repiaced and Replacement Components Narmeof Name of Manufacturer National Other Year Corrected.
ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)Si-873A Edwards N/A N/A Check valve 1971 Removed N Sl-873A Edwards 40BCG N/A Check valve 2005 Installed N Piping Ebasco NIA N/A 2-SI-65 1971 Removed N Piping Dubose N/A NWA 2-SI-65 2005 Installed N 7. Description of Work: Replaced valve and pine pieces 8. Test Conducted:
Hydrostatic LIj Pneumatic 1 1 Nominal Operating Pressure QXJ Exempt (-]Other [EPT Pressure lN~'PJ psig Test Temp. [WOTI &deg;F 05-019
-s1 Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 664068 turnover packace.Applicable Marufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate pLAthem No. N/A Signed ISI ENGINEER Date 10/23/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 9/13/2005 to 10/2312005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements cif the ASME Code, Section Xl.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
________Commissions NC 1507 nsp 's tgnature National Board, State, Province, and Endorsements Date:10/23/2005 05-019 Form NIS 2.1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi I 1. Owner PROGRESS ENERGY CAROLINASJ ING Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC' 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Date: 10/25/2005 Sheet: Unit:-1 of 2 2 EC#:N/A EE:NfA WRMWO:581883 CR:N/A Repair Organization PO NoWJob No:etc.Type Code Symbol Stamp: NIA Authorization No.: N/A Expiration Date: N/A Address Identification of System: Class:2 4.5.r-LJ~Alf'Ad AKfl Vnl~i I IP&A= fYrdT~elI QVQT=&R Orn 1. -.--'. ---.----(a) Applicable Construction Code: B31.1 Edition: 1967 Addenda:N.A Code Case Design Specification:
883D391 (b) Applicable Edition o Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N-416-2:N/A 0 6. Identition d Components Hepaired or Heplaced and Heplacement uompnents Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)LTDN- Westinghouse N/A N/A Restricting orifice 1971 Removed N ORIFICE-A LTDN- Energy Steel & N/A N/A Restricting orifice 2005 Installed N ORIFICE-A Supply 7. Description of Work: Replaced 'A' Letdown restricting orifice 8. Test Conducted:
Hydrostatic I Pneumatic U ] Nominal Operating Pressure %J Exempt (-I Other IVT-21 Pressure [NOPI psig Test Temp. INOTI 0 F 05-020 0 Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)0 Sheet 2 of 2.9. Remarks: See WO 581883 turnover package Applicable Manufacturer's Data Reports to be attached CERTHIrCATE OF COMPLIANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate o0 e Yo. N/A Signed 4 ISI ENGINEER Date 1012512005 Owner or Owner's Designee, rifle CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described In this Owner's Report during the period 11/16/2004 to 10125/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
/ pAAg; c_ ___GCommissions NC 1507 Inspect ture National Board, State, Province, and Endorsements Date:10125/2005 05020 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI F Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD; HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC n11.1 1 fliY;)N%Uutu. wcwcwv Sheet: 1 of 2 Unit: 2 EC#:51 861 EE:NA WR/WO:534701 CR:N/A Repair Organization PO No-Job No;etc.Type Code Symbol Stamp: NA Authorization No.: N/A Exdration Data: NIA Name S5R1 WFST ENTRANCE RD: HARTSVILLE SC 2'5wO------_Y.. _.._. ._._. _._ .._ ._4.5.Address Identification of System: Class:3 C OMPONENT COOLING WATER SYSTEM 4060 (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:NlA Code Case:NlA Design Specification:
CPL-HBR2-M-26 (b) Applicable Edition of Section XI Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N-416-2 Identification of flnmnnnants Rpnaired or Rpnlaacd and Ronlanpmant Comnonents 6 Name of Name of Manufacturer National Other Year Corrected.
ASME Component Manufacturer Serial No. Board No. Wdentificatlon BuIlt Removed, or Code Installed Stamp (Yes or No)CC-738 Ebasco N/A N/A Check Valve 1971 Removed N CC-738 Velan 50S N/A Check Valve 2004 Installed N 7.8.Description of Work: Replacing valve Test Conducted:
Hydrostatic U Pneumatic U-) Nominal Operating Pressure EXJ Exempt [-J Other [VT-21 Pressure MNOPM psig Test Temp. I[NOT OF 05-021 Form NIS2 1995 Edition 1996 Addenda SECTION Xl DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 534701 turnover package Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate k n No. N/A Signed -ISI ENGINEER Date 10/25/2004 Owner or Owner's Designee, Tile CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by I-SBCT of HARTFORD.
CONNECTICUT have inspected the components described In this Owner's Report during the period 4/15/2004 to 10/25/2004 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
G ______ Commissions NC 1507 In" Sgnature National Board, State, Province, and Eniorsements Date:10/25/2004 05-021
>r- %I 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S RElPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by thep Provisions of the ASME Code Section Xi FormNIS2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 2760:2 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
;C 29550 Date: 1217/2005 Sheet: 1 of 2 Unit:_2 EC#:56266 EE:NIA WRWO:6191461619161 CR:NtA Repair Organization PO No;Job No;etc.Type Code Symbol Stamp:. NtA Authorization No.: NWA Expiration Date: N/A 4.S.Address Identification of System: Class:1 REACTOR COOLANT SYSTEM 2005 (a) Applicable Construction Code: ASME III Edition: 1965 Addenda:NlA Code Case:N/A Design Specification:
418A12 (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A.W 6. Identirt or caGponens Repaired or aeplaced and Heacement Components Name of Name of Manufacturer National Other Year Corrected.
ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or NO)1-RC-2501R-Westinghouse NIA N/A RVUS Piping 1971 Removed N 99 1-RC-2501R-Westinghouse N/A N/A RVUS Piping 2005 Installed N 99 3t4-RC- Westing house N/A N/A RPV Head Vent 1971 Removed N 2501 R-27 piping_3/4-RC- Westinghouse N/A N/A RPV Head Vent 2005 Installed N 2501R-27 Piping RC-578 Ebasco N/A N/A Valve 1971 Removed N 7. Description of Work: Replaced RVUS and Head Vent piping and fittinas as part of RPV Head Replacement
: 8. Test Conducted:
Hydrostatic L-] Pneumatic frI Nominal Operating Pressure ri Exempt pq Other L Pressure [WLAJ psig Test Temp. INtA] 0 F 05.022 Form NIS2 1995 Edition 1996 Addenda SECTION XI DIVISION 1 S FORM NIS-2 (Back)Sheet 2 of 2 9. Remarks: See WO 619146/619151 and EC 56266 turnover Packaaes Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correci: and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate d As zibeiiaeo.
N/A Sitned % IMrI FNGINFFR Date 19fli7/2S; Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 9/21/2005 to 12/7/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector or his; employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury C; property damage or a loss of any kind arising from or connected with this inspection.
/72 u ( Commissions NC 1507 0-nspect 5 s S~l6nature National Board, State, Province, and Endorsements Date:12/712005 05-022 e Form NIS 2 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl 1. Owner PROGRESS ENERGY CAROLINAS, INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Date: I fIOPnnfl'. l W -W -VVO Sheet: 1 Of 2 Unit: 2 Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CA!ROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
;C 29550 EC#:56266 EE:N/A WRIWO:558600 CR:N/A Repair Organization PO No:Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A 4.5.Address Identification of System: Class:1 REACTOR VESSEL 1005 (a) Applicable Construction Code: ASME ll Edition: 1998 Addenda:2000 Code Case Design Specification:
418A12 (b) Applicable Edition of Section XI Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A e:N-525 6.Identifieation of Comnonnnntq Rpnairert nr Ranlacrpti and Renlanamont rnmonnentaq Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Seriat No. Board No. Identfication Built Removed, or Code Installed Stamp (Yes or No)RPV Head Westinghouse 66109 2928 N/A 1971 Removed Y RPV Head Westinghouse B-VH-N12 5853 N/A 2005 Installed Y..7. Description of Work: Redlaced RPV Head 8. Test Conducted:
Hydrostatic L-1 Pneumatic U.. Nominal Operating Pressure LXJ Exempt H-Other IVT-21 Pressure iNOPI psig Test Temp. MNOT &deg;F 05-023 I -If I I  Form NIS2 1995 Edition 1996 Addenda SECTION Xl DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See Form N-2 for NB Number 5853 (Attached)
Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate 0 No. N/A Signed 4 4m- IS ISI ENGINEER Date 10/26/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 9/21/2005 to 10/26/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
>___a__ _Commissions NC 1507 Ins ore Signature National Board, State, Province, and Endorsements Date:10/2612005 05-023 lRecord No.I -ioH-- FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code, Section L Not to Exceed One Day's Production Pg.1 Iof 1. Manulacture andoerfed by MITSUBISHI HEAW IIWSTRIES, LTD. KOBE SHIPYARD & MACHINERY WORKS 1t-, WADASAIt1CHO 1l.CHOME, HYOGO-KU, KOBE 652-8585 JAPAN msnead ma ms dNPTcMIs Holda4 2. Manufacred for PROGRESS NEtRGYCAROUNAS.
UJC./POWGRESS ENERGYSERVICE C0JPANY LC 411 Flvie ~ MauL 9aP, Nno2760-ui addrss of pu4hant 3. Location ot Insallation H.B. Robinson Nudear Power leneration Faclity Urnt 2 3851 West Entrance Rord Hattviile, SC USA 29550 (- -ii ad-m 4. Type L5IDS001 Rsv.2 SA508 Gr.3 CLI 80 to 105 ksl -L5-01 DS =0 Rev.2 2005__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _Wavf no.) (eana. Spo.) Dona* ,trPm (11 (tt4 6. ASME Code, Section II. Division1:
1998 AOO 1 N525 (4 dda dd a Ic.C m)6. Fabricated In accordance with ConsL Spec. (Dv.2 only) -evislon -Date tno 7. Remarks: 45 control rod drive mechanism (CRDMl oenetratons.
45 CRDM assembles.
2 vaent ninnw (one for RVHVS. ona fne RVIS). 45 nIlda funnALq. Intemart Cdaddna 2 dosura h Part A kavwavs- 2 einsura head Mifinn hij s8 ioud SuPport structu O throuch-holes for i 5._ __ ... _ ._. _ yy_. y .-8. Non. thickness (n) 7.95 Mn. desIgn thickness In.) 7.76 Dia.lD(ft&In.)
12'4.8" Laengthoverall(ftIn.)
28'7.19'9. Whonpplicabe.
Cercate Holders' Data Repons re attached for each Item of this report Part orApputtenance Part or Appurtenance Serial Number 13"'H_12 National Board No.In Numerical Order 853 _(1)12)(3)(4)(5)(6)O')(8)(1)(11)12)(13)(14)(16)(16)(17)(18)(19)(2)(21)(22)(23)(24)M I_-below blank I I 1 I-A CRDMassembly cons of the toowing.-Pressure housing essembly-Latch housIng-Rod travel housing 4 fiux ings-Latch assembly National PaIt or Appurtenance Board No.Serial Number In Numerical Order 826)(2 7) , _ _ __._._ _ _ __. _#29)t30)t32)(331 _ _ _ _ _ _4) _ _ _ _ _ _ _ _(35) _ _ _ _ _ _(37) -._.(381 40) _ _41)i __ _ __ _ __ _ __ _42) .r._ _ _ _ _ _ _ _ _ _ _ _(43) ._ _ _ _ _ _(44) __ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _(45)__ _ _ _ _ _ _ _(46) -_ _ _ _ _ _ _(47) _ _ _ _ _ _ _ _ _49) __ _ _ __ _ _ _ __ _ _ _(5 )_ _ _ _ _ _ _ _ _ ___________________________________________I_____________________
.10. Design pressure 2500 psal Temp. 650 *F. Hydro. Test pressure 3205 pa. at imp. 68 'F.C 2485 PuWl C P3le.)Suepnltmel Intrxrrna intheoinn olfits, skches, orsdrawinsmay beused proided (I) sze Is 3 'auxt, (2) normatonintes 2and 3ontis Da Report Is Inctuded on each rea. (3) each sheet Is nubetred and ihe mumabr of sheet Is recorded at the top of thls form.(7198) This form (EOOD40) may be obtained frorm the Order Dept., ASME. 22 Law DrIve. Box 2300. Fairfeld.
NJ 07007-2300 RRVCIr PECI RB.Robinsotr2 t P.O.3382 0039I MMI Section 2 -Page I FORM N-2 (Back -Pg 2 of _;j Certificate Holder's SWral Nos. _ -VH-N12 through CERT11:CATION OF DESIGN Design specifications cerfied by Harshad C. Jambusarla P.E. State SC Reg. no. 20824 Design report, certified by DulaOC. Bhominck PE State SC Reg. no. 21082 CERTIFICATE OF COMPUANCE Reactor Vessel Closure Head with 45 Control Rod We certify that the statements made In this report are correct and that this (these) Drive Mechanism conforms to the rules of construction of the ASME Code, Serxn M, Division t.NPT Certificate ofAuthorization No. N-2327 Evpires December a,2007 MtTSUBISHI HEAWI INDUSTRIES, LTD.Date k (rO oS Name KOBESHIPYARD&MACHINERYWORKS Signed _ _ _ _ __ _ _ _INPT CWIF.Mte Hol CERTIFICATE OF INSPECTION
: 1. the undersigned, holding a valid corwmlsion Issued by tie National Board of Boiler and Pressure Vassel Inspectors and the State or Province Of PA and employed by HARTFORD STEAM BOILER OF CONNECTICUT of HiTFORD. CT have inspected these Items described in tis Data Report on MAY 10.2005 , and state that to the best of my knowledge and belief, the Certificade Holder has fabricated these parts or appurtenances In accordance with the ASME Code, Section M, Division 1. Each part listed has been authorized for stamping on the date shown above.By signing this certificates, neither the Inspector nor his employer makes any wanenty, expressed or implied, concerning the equipment described in thts Data ReporL Furthermore, neither the hispector nor his employer shall be liable In any manner for any personal biury or property damage or loss of any kind arising from or connected with this pectiorn.Date / y /O4oO S' Signed Commissions Rt,&A3) o ,Z 3 9-:t4c I. Pd, endorh) wid or powd no.RRVCtr PEC I IBRobinson-2 t P.0.3382-0039 1 MIS 2 Section 2 -Page 2 r FORM N-2 (3 of C Certificate Holder's Serial Nos. B-VHWNI2 Uttough -Manufactured for PROGRESS ENERGY CAROUNAS.
INC. IPROGRESS ENERGY SEX COMIPANY.
tiC 411 Fawlee S. Mli.t Raln. Cic 27D2 Van* ld ress d g prchaint Location of instafation H.B. Robinson Nuclear Power Generation Facility Urit 2 3851 West Entrance Road Harvt-le, SC USA 29560#Wmi. aid addmess RHVCHW PEC I HiRRobinson-2 I P.0.3382-00391 MHI Section 2 -Page 3, ,
e 1995 Edition 1996 Addenda APPENDIX It MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST., RALEIGH. NC 2760 Date: 1 1/ S/2005nr w. .,. ,<Sheet: 1 of 3 Address Li D Dt^0lhI.I1^K1
: 2. P Pi -0I Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 Address Unit: 2 EC#:58305 EE:N/A WR/WO:564296 CR:N/A Repair Organization PO No;Job No~etc.Type Code Symbol Stamp: N/A Authorization No.: NWA Expiration Date: NWA 4.5.Identification of System: Class:3 I1'.A13DI%
i&jrT (ttV IKf- VATFr 0V0TSrU ANrbnW .. -I I ""I  (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case Design Specification:
N/A (b) Applicable Edition of Section Xl Used for lepair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N-416-2:N/A 6. Identifi ation of Componen Repaired or acedand Replacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Bunt Removed, or Code Installed Stamp (Yes or No)FI-660 Ebasco N/A NWA Flow Indicator 1971 Removed N Fl-660 Brooks N/A N/A Flow Indicator 2005 Installed N FE-660 Ebasco N/A N/A Flow Element 1971 Removed N CC-934 Velan 05-003-1 N/A Globe Valve 2005 Installed N CC-734A Ebasco NVA N/A Globe Valve 1971 Removed N CC-734A Velan MMOO84 N/A Globe Valve 2005 Installed N 7. Description of Work: Modifvina piving section and relocatinq FI-660 8. Test Conducted:
Hydrostatic L ] Pneumatic
[ 1 Nominal Operating Pressure W Exempt 'X]Other VT21 Pressure INOPI psig Test Temp. [NOT] &deg;F 05024 e 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON n.#-.41 1 .1Mrnr I #I Sheet: 2 of 3 Unit:_2 Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 EC4:58305 EE:N/A WRIWO:564296 CR:N1A Repair Organization PO NoJob No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: NWA Address Identification of System: Class:3 4.5.COMPONENT COOLING WATER SYSTEM 408Q (a) ApplicableConstructionCode:
B3.1 Edition: 1967 Addenda:N/A Code Case Design Specification:
N/A (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N-416-2:NtA 6. Identification of Components Repaired or Hep-- and Repacement Componts-Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identificaton Built Removed, or Code Installed Stamp (Yes or No)CC-734B Ebasco NIA N/A Globe Valve 1971 Removed N CC-734B Velan MMOOB4 NIA Globe Valve 2005 Installed N 3-AC-152N-Ebasco N/A N/A 3 Piping 1971 Removed N 3-AC-152N-Maintenance N/A NIA 3" Piping 2005 Installed N 2-AC-152N Ebasco N/A N/A 2" Piping 1971 Removed N 2-AC-152N Maintenance N/A N/A 2 Piping 2005 Installed N 7. Description of Work: Modifying vivino section and relocating FI-660 8. Test Conducted:
Hydrostatic H Pneumatic U1 Nominal Operating Pressure [X Exempt [XJ Other IVT-21 Pressure 1N0P] psig Test Temp. (NOT] OF 05-024 Form NIS2 1995 Edition 1996 Addenda SECTION XI DIVISION 1 FC)RM NIS-2 (Back)Am Sheet 3 of 3.9. Remarks: See WO 564296/EC58305 turnover packaaes Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I cerfify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate
= zao. N/A Signed A ISI ENGINEER Date 11/16/2 5 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owners Report during the period 9/19/2005 to 11/1612005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements c the ASME Code, Section XI.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
&deg; 0 6. Commissions NC 1507 InsW ofSinature National Board, State. Province, and Endorsements Date:1 1116/2005 05-024 1995 Edition 1996 Addenda.APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI Form NiS 2 I ---1. Owner PROGRESS ENERGY CAROLIN!S.
INC Name 411 FAYETTEVILLE ST.. RALEIGH, NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS, INC Name 3581 WES(T FNTRANCE RD: HARTSVI I F 2 RC 95509;A na#-I1 It Ponlonniz JOl*. I IM-Sheet: I of 2 Unit: 2 EC#:N/A EE:NIA WR/WO:767472 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamrp; NIA Ai thriMatinn No NIA I....r.a..i Da...Expiration Date:, N/A---, ---- -- -- -----4.5.Address Identification of System: Class:2 MAIN STEAM SYSTEM 3020 (a) Applicable Construction Code: AISC Edition: NIA Addenda:NJA Code Case:N/A Design Specification: (b) Applicable Edition of Section XI Used for Repair/Replacement Activity:
1995 Editon 1996 Addenda Code Case: N/A Identifiticaifn of Comoonents Renairnd or Reoilacrd and Rdanpement onmoonents 6.Name of Name of Manufacturer National Other Year Corrected.
ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)213iF-WS Ebasco N/A N/A Piping restraint 1971 Corrected N_ _ _ _ _ _ _ _ _ _M S-11B-b _ _ _7.8.Description of Work: Weld repair of restraint structure stiffener plate Test Conducted:
Hydrostatic LI] Pneumatic L-] Nominal Operating Pressure f] Exempt H Other IVT-31 Pressure [N/A] psig Test Temp. fN/Al &deg;F 05-025 Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)At Sheet 2 of 2.9. Remarks: See WO 767472 turnover eackace.Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are corred and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certficat at No. N/A Signed CISI ENGINEER Date 1218/2005 Owner or Owner's Designee, Title CERTIFICATE!
OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 10/6/2005 to 12/8/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
(_ ______ Commissions NC 1507 Inspe aesgnature National Board, State, Province, and Endorsements Date:1 2/8/2005 05-025 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Date: 1212/2005 Sheet: 1 Of 2 Unit: 2 EC#:NIA EE:NIA WR/WO 662477 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: NIA Authorization No.: N/A Expiration Date: NWA 4.5.Address Identification of System: Class:2 RESIDUAL HEAT REMOVAL SYSTEM 2045 (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case:N/A Design Specification:
N/A (b) Applicable Edition of Section Xi Used for RepairlReplacement Activity:
1995 Edition 1996 Addenda Code Case: N/A 6. Identification of Components Repaired or Replaced and Re lacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)Snubber #20 Grinnell 3221 N/A Hydraulic 1998 Removed N Snubber Snubber #20 Grinnell 34439 N/A Hydraulic 2005 Installed N Snubber ____7.B.Description of Work: Replaced snubber Test Conducted:
Hydrostatic El Pneumatic I U Nominal Operating Pressure U Exempt [-]Other [IT-31 Pressure KN/AI psig Test Temp. [WA] 'F 05-026 Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 662477 turnover package and EST-033 Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made hI the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A CertificatNO N/A Signed 4 C ISI ENGINEER Date 12/9/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 10/8/2005 to 12/9(2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
____ ___Commissions NC 1507 I-ns--,ris Sl ature National Board, State, Province, and Endorsements Date:12/9/2005 05-026 e 1995 Edition 1996 Addenda 0ft APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl 10 Form NIS 2 1. Owner PROGRESS ENERGY CAROLINASU INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602_Date: i122/n00 wow. .cows Sheet: 1 of 2 Address Li e 0r%01rt1Nj%
: 2. P I.--.1I4% .I.tJ II.% U Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE-SC 29550 Unit: 2 EC#:N/A EE:N/A WRIWO,544849 CR:NJA Repair Organizatin PO No;Job No~etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A A 3050 Address Identification of System: Class:3 4.5.FFF WATFR qYqTFP... ----_ ._(a) Applicable Construction Code: B 31.1 Edition: 1967 Adenda:N/A CodeCase Design Specification:
5379-01397 SH1 (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: NWA e:N/A 6.Identification of Components Repaired or Replaced and Replacement Components
= ---U = a Name of Name of Manufacturer Nahonal Other Year Corrected.
ASME Nameot Component Name Sn Manufacturer Manufacturer Serial No.Natioa'Board No.Other Identification Year Built Corrected S Removed, or Inlstalled ASME Code Stamp (Yes or No)FCV-478 Copes-Vulcan N/A NA Bonnet Stud 1971 Removed N FCV-478 Copes Vulcan NIA N/A Bonnet Stud 1986 Installed N FCV-478 Copes Vulcan N/A NA Bonnet Nut 1971 Removed N FCV-478 Mackson NA NIA Bonnet Nut 2001 Installed N 7. Description of Work: Replaced one stud and one nut damaged during maintenance.
: 8. Test Conducted:
Hydrostatic U1 Pneumatic U Nominal Operating Pressure Il Exempt N Other [] Pressure IN/AI psig Test Temp. IN/Al 'F 05-O027 Form NIS2 199S Edition 1996 Addenda SECTION XI DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 544849 turnover packace Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correcs and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certlficati of Autotion No. N/A Signed- A IS ENGINEER Date 12/5/2005 Owner or Owners Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 9/2 005 to 12/5/2005 and state that to the best of my knowledge and belief, the Owner has peilormed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.-
ths in n Commissions NC 1507 Inspect Snature National Board, State, Province, and Endorsements Date:1 2/5/2005 05-027-1'.
I 0ND 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH, NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, S;C 29550 Date: 12/2/2005 Sheet: 1 of 2 Unit: 2 EC#:N/A EE:N/A WR/WO:544818 CR:N/A Repair Organization PO NoJob No;etc.Type Code Symbol Stamp: N/A Authorization No.: NWA Expiration Date: N/A A '13020 Address irtantifi1p-tienn ei qviqtnm. I KRAIN ATFAM qVRTFIJ 4.5.(a) Applicable Construction Code: B31.1 Edition: 1967 Addenda:N/A Code Case;N/A Design Specification: (b) Applicable Edition of Section XI Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A Identification of Comoonents Renaired or Renlaced and Renlacement Cornnonants 6.=- *_:-- ----_______ _ _ =-Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)MS-263A Vogt N/A N/A Piston 1971 Removed N MS-263A Vogt N/A N/A Piston 1991 Installed N__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _7.8.Description of Work: replaced valve piston Test Conducted:
Hydrostatic fj Pneumatic
[U] Nominal Operating Pressure [1U Exempt I-)Other [N/Al Pressure "Ad psig Test Temp. IN/Al 0 F 05.028 Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION .FORM NIS-2 (Back)A1 Sheet 2 of 2 9. Remarks: See WO 544818 turnover Mackage Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Cede Symbol Stamp N/A Certificatepl ateo. .N/A Signed ISI ENGINEER Date 12/5/2005 Owner or Owner's Designee, Title CERTIFICATE:
OF INSERVICE INSPECTION
: 1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD, CONNECTICUT have inspected the components described in this Owners Report during the period 9/2512005 to 12/5/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.*P By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury Co property damage or a loss of any kind arising from or connected with this inspection.
9___ ____ Commissions NC 1507 Ins atSignature National Board, State, Province, and Endorsements Date:1215/2005 05-028 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH, NC 2760:2 r%--41n(YU;ff wattr Sheet: I of 2 Address WI R 0f%0M1frNI
: 2. Plant Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Unit: 2 EC#:N/A EE:NIA WRNVO:664066 CR:N/A Repair Organization P0 No-Job No;etc.Type Code Symbol Stamp: NMA Authorization No.: NIA Expiration Date: N/A 4.5.Address Identification of System: Class:2 SAFETY INJECTION SYSTEM 2080 (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case: NIA Design Specification:
CPL-HBR2-M-048 (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity 1995 Edition 1996 Addenda Code Case: N-416-2 6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other year Corrected.
ASME Component Manufacturer Serial No. Board No. Identification Buit Removed, or Code Installed Stamp (Yes or No)SI-873B Edwards N/A N/A Check valve 1971 Removed N SI-873B Edwards SONC24 N/A Check valve 2005 Installed N Piping Ebasco N/A N/A 2-SI-64 1971 Removed N Piping Dubose N/A N/A 2-SI-64 2005 Installed N 7. Description of Work: Replaced valve and opie rieces 8. Test Conducted.
Hydrostatic f U Pneumatic LI Nominal Operating Pressure [X) Exempt [-l Other [FP Pressure MP] psig Test Temp. [NOfl 0 F 05-029 Form NIS2 1995 Edition 1996 Addenda SECTION Xl DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 664066 turnover package Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct: and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Cerfific N/A Signed A4 t ISI ENGINEER Date 12/7/2005 Owner or Owner's Designee, Tie CERTIFICATE-OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 9/1312005 to 12/7/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xl.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection.
___ _ _Commissions NC 1507 pecJ SIgature National Board, State, Province, and Endorsements Date: 12(7/2005 05-029
'I 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S RElPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Data: 121612F0lon w.w. s.v__Sheet: 1 of 3 Address 14 n MrIMKI0r 2. F 0l...lM t I*LJftlI*Kl Name 3581 WEST Entrance RD: HARTSVILLE, SC :9550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD; HARTSVILLE, SC 29550 Unit: 2 EC#:58640 EE:N/A WR/WO:633486 CR;N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A 4.5.Address Identification of System: Class:2 SAFETY INJECTION SYSTEM 2080 (a) Applicable Construction Code: 831.1 Edition: 1967 Addenda:N/A Code Case:Nl/A Design Specification:
CPL-HBR2-M-048 (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: NI1A Identification of ComDonents Repaired or Renlaced and Reolacement Comoonents 6.Name of Name of Manufacturer National Otler Year Correed, ASME Component Manufacturer Serial No. Board No. Identification Buift Removed, or Code Installed Stamp (Yes or NO)6-SI-30 Maintenance N/A NIA Piping 2004 Removed N 6-SI-30 Maintenance N/A N/A Piping 2005 Installed N 6-SI-31 Maintenance N/A N/A Piping 2004 Removed N 6-SI-31 Maintenance N1A N/A Piping 2005 Installed N 4-SI-244 Maintenance N/A N/A Piping 2004 Removed N 4-SI-244 Maintenance N/A NIA Piping 2005 Installed N 7. Description of Work: Modified 'A and *B- Conlainment Spray Pump discharae pipin 8. Test Conducted:
Hydrostatic jM Pneumatic Lj Nominal Operating Pressure U Exempt [-Other IVT-21 Pressure 13751 psig Test Temp. [NOT] &deg;F 05-030 4-1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi Form NIS 2 I-1. Owner PROGRESS ENERGY CAROLINAS.
ING Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Dnte: 12/6F/200 w9.Sheet: 2 of 3 Address i- R l=f.1CNN:K8
: 2. F 11-4f milt Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Unit: 2 EC#:58640 EE:NIA WR/WO:633486 CR:NtA Repair Organization PO No;Job No;etc.Type Code Symbol Stamp. N1A Authorization No.: NIA Expiration Date: NtA Address 4.5.Identification of System: Class:2 SAFETY INJFCTION SYSTFM 2080 (a) Applicable Construction Code: B 31.1 Edition: 1fl7 Addenda:N/A Code Case Design Specification:
CPL-HBR2-M-048 (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: NWA e:NlA 6.Identification of Comoonents Reoaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Corrected.
ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)4-SI-245 Maintenance N/A N/A Piping 2004 Removed N 4-SI-245 Maintenance N/A N/A Piping 2005 Installed N 2-SI-151 Maintenance NtA N/A Piping 2004 Removed N 2-SI-151 Maintenance NtA N/A Piping 2005 Installed N 2SI-152 Maintenance N/A N/A Piping 2004 Removed N 2-SI-152 Maintenance N/A N/A Piping 2005 Installed N 7. Description of Work: Modified A' and 813 Containment Spray Pumo discharge Piing 8. Test Conducted:
Hydrostatic LXJ Pneumatic U Nominal Operating Pressure EJ Exempt [-]Other [VT-21 Pressure f3751 psig Test Temp. [NOT1 IF 05-030
-I Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)* Sheet 3 of 3 9. Remarks: See WO 633486 and EC 58640 turnover packages Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificat c t No. N/A Signed 4 ISI ENGINEER Date 12/6/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owners Report during the period 4/21/2005 to 1216/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code. Section Xi.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
is *____ Commissions NC 1507 Insdoer gegnature National Board, State, Province, and Endorsements Date:121612005 05-030 1995 Edition 1996 Addenda 0 Af APPENDIX 1i MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRJREOLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xi* Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS, INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Oa~t: 191/219MM* --- --Sheet: 1 of 2 Address Li D nMfClK1 2. P I-*.pu.. F I.Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 Unit: 2 EC#:N/A EE:N/A WR/WO:662682 CR:NIA Repair Organization PO No-Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: NWA Expiration Date: N/A 4.5.Address Identification of System: Class:2 C:HEMICAL AND VOLUME CONTROL SYSTEM 2060 (a) Applicable Construction Code: B31.1 Edition: 1967 Addenda:N/A Code Case:NIA Design Specification:
N/A (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 EdItion 1996 Addenda Code Case: N/A 6. Identification of Components Repaired or Re laced and Replacement Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)Snubber #23 Grinnell 34033 N/A Hydraulic 1998 Removed N Snubber Snubber #23 Grinnell 35487 NIA Hydraulic 2005 Installed N Snubber ,_v 7. Description of Work: Replaced snubber 8. Test Conducted:
Hydrostatic U1 Pneumatic U 1 Nominal Operating Pressure U] Exempt [-J Other IVT-3/Functionafl Pressure IN/Al psig Test Temp. INA] OF 05-031 Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)Sheet 2 of L 9. Remarks: See WO 662682 turnover package Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made In the report are correci and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate
{ NIA Signed 4 8- ISI ENGINEER Date 12/5/2005 Owner or Owners Designee, Title CERTIFICATE:
OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 101812005 to 12/512005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
&deg;a4 ________Commissions NC 1507 Ins Itef Signature National Board, State, Province, and Endorsements Date:1 2/5/2005 05i031 1995 Edition 1996 Addenda 0 APPENDIX 11 MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by thei Provisions of the ASME Code Section Xi Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.8.ROBINSON Date: 1215/2005-------Sheet: 1 Of 2 Unit:_2 Name 3581 WEST Entrance RD: HARTSVILLE.
SC O9550 I Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 EC#:60960 EE:NtA WR/WO:703718 01 CR:NIA Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: NIA Expiration Date:- N/A 4.5.Address Identification of System: Class:2 STEAM GENERATOR SYSTEM 3005 (a) Applicable Construction Code: ASME III Edition: 1965 AddendaJNIA Code Case-N/A Design Specification:
N/A (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A b. Identification of Components Hepaired or Heplsced and He xacement Cornponents Name of Name of Manufacturer National Other Year Corrected.
ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)S/G A Westinghouse N/A N/A Bolts 1984 Removed N Manway S/G A Mackson N/A N/A Studs 2005 Installed N Manway .-SIG A Nova N/A N/A Nuts 2005 Installed N Manway 7. Description of Work: Replaced bolts with studsfnuts to support temporary repair of mechanical connection.
: 8. Test Conducted:
Hydrostatic 1U Pneumatic U. Nominal Operating Pressure LI Exempt [XI Other INIA] Pressure fWAI psig Test Temp. fN/A1 &deg;F 05-032 Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 703718 01 and EC 60960 turnover oackaoes Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certif 4Axrtz No. N/A SignedA G W I 151 ENGINEER Date 12/5/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 5/4/2005 to 12/5/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASMIE Code, Section Xi.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury om property damage or a loss of any kind arising from or connected with this inspection.
0______Commissions NC 1507 Inspe s Agnature National Board, State, Province, and Endorsements Date:12/512005 05032 0 0 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE.
SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE, SC 29550 Date: 12/5/2005 Sheet: 1 of 2 Unit: 2 EC#:N/A EE:N/A WRIWO:703718 05 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A 4.5.Address Identification of System: Class:2 STEAM GENERATOR SYSTEM 3005 (a) Applicable Construction Code: ASME III Edition: 1965 Addenda:N/A Code Case:N/A Design Specification:
N/A (b) Applicable Edition of Section Xl Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A Identification of Comnonents Repaired or Renalced and Renlacement Comronants 6.Name of Name of Manufacturer National Other Year Corrected.
ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)S/G A Westinghouse N/A N/A Manway Cover 1984 Removed N Manway SIG A Westinghouse A-0011 N/A Manway Cover 1993 Installed N Manway S/G A Nova N/A N/A Threaded Inserts 2005 Installed N Manway .. _7.8.Description of Work: Reolaced Manwav cover, threaded inserts and machined Manwav Dad and cover sealing surfaces Test Conducted:
Hydrostatic LI Pneumatic L-] Nominal Operating Pressure Q9 Exempt [-]Other [VT-21 Pressure [NOPI psig Test Temp. INOQ1 OF 05-033 a A Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)e Sheet 2 of 2.9. Remarks: See WO 703718 turnoerepackage Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code. Section Xi.Type Code Symbol Stamp NWA Cerificat t No. NIA Signed -A A U- IS! ENGINEER Date 12/512005 Owner or Owner's Designee, Title Aft W CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 8/23/2005 to 12/5/20Q5 and state that to the best of my knowledge and belief, the Owner has pelrormed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
7'(~zU4 (Commissions NC 1507 f-nspecto(dyture National Board, State, Provnce, and Endorsements Date: 1 215/2005 05-033
-fi -1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl* Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS, INC Name 411 FAYETTEVILLE ST., RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE.
SC' 29550 Address 3. Work Performed by PROGRESS ENERGY CAPROLINAS.
INC Name 35A1 WEST FNTRANCEF Rnl: HARTAVII I F Prl 29550 Date: 12/5/2005 Sheet: 1 of 2 Unit: 2 EC#:NIA EE-NIA WR/WO:703490 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: NIA Expiration Date: NIA Address-.r, 4. Identification of System: Class:2 STEAM GENERATOR SYSTEM 3005 5. (a) Applicable Construction Code: ASME Ill Edition: 1965 Addenda:N/A Code Case:N/A Design Specification: (b) Applicable Edition of Section Xi Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A 6. Identification of Comoonents Repaired or Replaced and Reolacement Comnonents Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)S/G A Mackson N/A N/A Studs 2005 Removed N Manway_S/G A Nova NWA A Nuts 2005 Removed N Manway S/G A Westinghouse N/A N/A Bolts 1992 Installed N Manway .=7.8.Description of Work, Reolacing studs and nuts installed Per EC 60963 and WO 70371 8 01 with bolts Test Conducted:
Hydrostatic lU, Pneumatic Ij Nominal Operating Pressure Ij Exempt [X]Other IN/A1 Pressure [lNA psig Test Temp. IN/Al 0 F 05-034 0.Form NIS2 1995 Edition 1996 Addenda SECTION XI DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 703490 turnover oackage Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A IOL-f- lrlk t WLI IWA i Signed 'A a C ' -ISI ENGINEER Date 12/5J2005 Owner or Owners Designee, Title CERTIFICATE:
OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owners Report during the period 9/1912005 to 1215/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
SI X ________Comnmissions NC 1507 nsper ignature National Board, State, Province, and Endorsements Date:12/512005 05-034 Form NIS 2 S 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIRIREPLACEMENT ACTIVITY As Required by thi Provisions of the ASME Code Section XI 1. Owner PROGRESS ENERGY CAROLINAS, INC Name 411 FAYETTEVILLE ST., RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Date: 12/6/2005 Sheet: I Of 2 Unit: 2 EC#:NJA EE:N/A WR/WO:554808 CR:N/A Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: N/A-Address 4. Identification of System: Class:3 FEED WATER SYSTEM 3050 5. (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case:N/A Design Specification: (b) Applicable Edition of Section XI Used for RepairlReplacement Activity:
1995 Edition 1996 Addenda Code Case: N/A 6. Identification of Comoonents Reoaired or Reolaced and Reolacement Comoonents Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)FE-496 Maintenance N/A N/A Venturi tack 1971 Removed N welds FE-496 Maintenance NA N/A Venturi tack 2005 Installed N welds 7.8.Description of Work: Removed and re-welded Venuri tack welds for inspection Test Conducted:
Hydrostatic Uj Pneumatic U1 Nominal Operating Pressure 1.1 Exempt [X]Other IN/Al Pressure 04/Al psig Test Temp. [INA1 IF 05M035 Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 554808 turnover Dackacte Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate
-i-on .N/A Signed 'A a Q L- ISI ENGINEER Date 12/612005 Owner or Owner's Designee, Title.CERTIFICATE:
OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owner's Report during the period 10/9/2005 to 12/6/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
NC 1507 National Board, State, Province, and Endorsements Date: 1 26/2005 05-035 Form NIS 2 1995 Edition 1996 Addenda APPENDIX If MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section Xl 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST.. RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS.
INC Name 3581 WEST ENTRANCE RD: HARTSVILLE.
SC 29550 Date: i 5pinrintz Sheet: 1 of 2 Unit: 2 EC#:N/A EE:N/A WRIWO:559034 CR:NIA Repair Organization PO No;Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date: NIA-Address 4. Identification of System: Class:3 FEED WATER SYSTEM 3050 5. (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case: N/A Design Specification: (b) Applicable Edition of Section Xi Used for Repair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A 6. Identification of Comoonents Reoaired or Replaced and Replacement Comoonents
= ~ ~~ =, ___a _ ____. =, _ ,=----,-,:, Name of Name of Manufacturer National Other Year Corrected.
ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)FE-476 Maintenance N/A NA Venturi tack 1971 Removed N.welds FE-476 Maintenance N/A N/A Venturi tack 2005 Installed N welds l 7.a.Description of Work: Removed and re-welded tack welds for inspection Test Conducted:
Hydrostatic 1:1 Pneumatic EJ Nominal Operating Pressure U 1 Exempt [X]Other [N/A] Pressure L" psig Test Temp. INIA1 OF 05-036 Form NIS2 1995 Edition 1996 Addenda SECTION Xi DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 559034 turnover oackaoe Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certifica N/A Signed 4 ISI ENGINEER Date 1216/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD, CONNECTICUT have inspected the components described in this Owners Report during the period 10/9/2005 to 12/6/2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector or hi; employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection..
this insp n Commissions NC 1507 Irlspecto, k nature National Board, State, Province, and Endorsements Date: 12/6/2005 054036 80<4 : 1995 Edition 1996 Addenda APPENDIX II MANDATORY FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by tho Provisions of the ASME Code Section Xl Form NIS 2 1. Owner PROGRESS ENERGY CAROLINAS.
INC Name 411 FAYETTEVILLE ST., RALEIGH. NC 27602 Address 2. Plant H.B.ROBINSON Name 3581 WEST Entrance RD: HARTSVILLE, SC 29550 Address 3. Work Performed by PROGRESS ENERGY CAROLINAS, INC Name 3581 WEST ENTRANCE RO: HAPTSVILLE.
SC 29550 nrl--t -5F7^flnfr Iu.1- -,,w Sheet: 1 of 2 Unit: 2 EC#:N/A EE:N/A WR/WO:664191 CR:N/A Repair Organization PO No.Job No;etc.Type Code Symbol Stamp: N/A Authorization No.: N/A Expiration Date. NMA Address 4. Identification of System. Class:2 CHEMICAL AND VOLUME CONTROL SYSTEM 2060 5. (a) Applicable Construction Code: B 31.1 Edition: 1967 Addenda:N/A Code Case:N/A Design Specification: (b) Applicable Edition of Section Xl Used for Flepair/Replacement Activity:
1995 Edition 1996 Addenda Code Case: N/A 6. Identification of Components Repaired or Replaced and Reolacement CGononents Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial No. Board No. Identification Built Removed, or Code Installed Stamp (Yes or No)Snubber #35 Grinnell 32212 NWA Hydraulic 1998 Removed N__ __ _ Snubber _Snubber #35 Grinnell 34607, NA Hydraulic 2005 Installed N__ Snubber 4 4 5- .4 4 5 4 4 I- 4 + 1 4___________________________
.5. _______________________________
.4 ___________________________
L = -.a-___________________________
.= = .-+/- __________________
I ____________________________
7.8.Description of Work: Replaced snubber Test Conducted:
Hydrostatic U 1 Pneumatic 1U Nominal Operating Pressure U Exempt 1-)Other [VTJ81 Pressure [l/Aj psig Test Temp. tIN/Al OF 05-037 I Form NIS2 1995 Edition 1996 Addenda SECTION XI DIVISION 1 FORM NIS-2 (Back)Sheet 2 of 2.9. Remarks: See WO 664191 turnover packaae Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE I certify that the statements made In the report are correct and this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp N/A CiW N/A Signed ISI ENGINEER Date 1217/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSBCT of HARTFORD.
CONNECTICUT have inspected the components described in this Owners Report during the period 10/8/2005 to 12/7I2005 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector or his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions NC 1507 Inspe tre National Board, State, Province, and Endorsements Date:121712005 05-037}}

Latest revision as of 01:26, 14 July 2019