ML17264B163: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 3: Line 3:
| issue date = 09/27/2017
| issue date = 09/27/2017
| title = Audit Summary for Nuscale Chf_Non_Prop Version
| title = Audit Summary for Nuscale Chf_Non_Prop Version
| author name = Bavol B M
| author name = Bavol B
| author affiliation = NRC/NRO/DNRL/LB1
| author affiliation = NRC/NRO/DNRL/LB1
| addressee name = Lee S S
| addressee name = Lee S
| addressee affiliation = NRC/NRO/DNRL/LB1
| addressee affiliation = NRC/NRO/DNRL/LB1
| docket = PROJ0769
| docket = PROJ0769
| license number =  
| license number =  
| contact person = Bavol B M
| contact person = Bavol B
| document type = Memoranda
| document type = Memoranda
| page count = 2
| page count = 2

Revision as of 03:10, 19 June 2019

Audit Summary for Nuscale Chf_Non_Prop Version
ML17264B163
Person / Time
Site: PROJ0769
Issue date: 09/27/2017
From: Bavol B
NRC/NRO/DNRL/LB1
To: Samson Lee
NRC/NRO/DNRL/LB1
Bavol B
References
Download: ML17264B163 (2)


Text

OFFICIAL USE ONLY PROPRIETARY INFORMATION OFFICIAL USE ONLY PROPRIETARY INFORMATION September 27, 2017

MEMORANDUM TO: Samuel S. Lee, Chief Licensing Branch 1 Division of New Reactor Licensing

Office of New Reactors FROM: Bruce M. Bavol, Project Manager

/RA/ Licensing Branch 1 Division of New Reactor Licensing

Office of New Reactors

SUBJECT:

AUDIT

SUMMARY

FOR NUSCALE TOPICAL REPORT TR-0116-21012, "NUSCALE POWER CRITICAL HEAT FLUX CORRELATION NSP2," REVISION 0 The U.S. Nuclear Regulatory Commission (NRC) staff conducted an audit June 13-15, 2017, to review Topical Report (TR) TR-0116-21012, Revision 0, "NuScale Power Critical Heat Flux Correlation NSP2." The purpose of TR-0116-21012 is to provide the bases for NRC approval to use the NSP2 critical heat flux correlation in VIPRE-01, within its range of applicability, along with its associated correlation limit, for the NuScale Design Certification Application and safety analysis of the NuScale Power Module with NuFuel-HTP2TM fuel.

The enclosed audit summary describes the content of the review, identifies the audit participants, and audit exit observations.

Project No. 0769

Enclosures:

1. Audit Summary - (Non-Proprietary)
2. Audit Summary - (Proprietary)

CONTACT: Bruce M. Bavol, NRO/DNRL 301-415-6715

cc w/encl.: DC NuScale Power, LLC Listserv (w/o Enclosure 2) Document transmitted herewith contains sensitive unclassified information. When separated from the enclosure, this document is "DECONTROLLED."

Pkg: ML17268A191 Memo: ML17264B153 Enclosure No. 1:ML17264B163 Enclosure No. 2:ML17268A189 *via email NRO-002 OFFICE NRO/DNRL/LB1: PM NRO/DNRL/LB1: LA NRO/DSRA/SRSB: BC NRO/DNRL/LB1: BC NAME BBavol SGreen* BKaras SLee DATE 9/27/2017 9/25/2017 9/27/2017 9/27/2017