| issue date = 04/16/2014 | |||
| title = Enclosure 3: Vogtle Annual Radioactive Effluent Release Report for 2013 | |||
| author name = Olive C | |||
| author affiliation = Southern Nuclear Operating Co, Inc | |||
| addressee name = | |||
| addressee affiliation = NRC/NRR | |||
| docket = 05000424, 05000425 | |||
| license number = NPF-068, NPF-081 | |||
| contact person = | |||
| case reference number = NL-14-0659 | |||
| package number = ML14125A094 | |||
| document type = Periodic Monitoring Report (Radiological/Environmental) | |||
| page count = 336 | |||
}} | |||
=Text= | |||
{{#Wiki_filter:Edwin I. Hatch Nuclear Plant Joseph M. Farley Nuclear Plant Vogtle Electric Generating Plant Annual Radioactive Effluent Release Reports and Offsite Dose Calculation Manuals for 2013 Enclosure 3 Vogtle Annual Radioactive Effluent Release Report for 2013 SOUTHERN NUCLEAR COMPANY VOGTLE ELECTRIC GENERATING PLANT- UNITS 1 AND 2 NRC DOCKET NOS. 50-424 AND 50-425 FACILITY OPERATING LICENSE NOS. NPF-68 AND NPF-81 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR JANUARY 1, 2013 TO DECEMBER 31, 2013 Preparedby: | |||
OIL) 3d11#Reviewed byoltV7 4Y4 LA/Page 85 of 503 VOGTLE ELECTRIC GENERATING PLANT RADIOACTIVE EFFLUENT RELEASE REPORT -2013 TABLE OF CONTENTS TITLE PAGE SECTION 1.0 1.1 1.1.1 1.1.2 1.2 1.3 1.3.1 1.3.2 1.4 1.5 1.6 1.7 Table 1-1A Table 1-1 B Table 1-1C Liquid Effluents Regulatory Requirements Concentration Limits Dose Limits Effluent Concentration Limit (ECL)Measurements and Approximations of Total Radioactivity Total Radioactivity Determination Total Error Estimation Liquid Effluent Release Data Radiological Impact Due to Liquid Releases Liquid Effluents | |||
-Batch Releases Liquid Effluents | |||
-Abnormal Releases Liquid Effluents | |||
-Summation of All Releases Unit 1 (Quarters 1,2,3, and 4)Liquid Effluents | |||
-Summation of All Releases Unit 2 (Quarters 1,2,3, and 4)Liquid Effluents | |||
-Summation of All Releases Site (Quarters 1,2,3, and 4)Liquid Effluents -Unit I (Quarters 1,2,3, and 4)Liquid Effluents -Unit I (Quarters 1,2,3, and 4)Page 86 of 503 92 92 92 92 92 93 93 95 96 96 96 96 97 99 101 102 106 Table Table 1-2A 1-2B Table 1-2C Table 1-3A Table 1-3B Table 1-3C Table 1-4 Table 1-5A Table 1-5B Table 1-5C Table 1-6A Table 1-6A Table 1-6C 2.0 2.1 2.1.1 2.1.2 Liquid Effluents -Unit I (Quarters 1,2,3, and 4) 108 Doses to a Member of the Public Due to Liquid Releases Unit I (Quarters 1,2,3, and 4) 111 Doses to a Member of the Public Due to Liquid Releases Unit 2 (Quarters 1,2,3, and 4) 113 Doses to a Member of the Public Due to Liquid Releases Site (Quarters 1,2,3, and 4) 114 Minimum Detectable Concentration | |||
-Liquid 115 Liquid Effluents Batch Release Summary Unit I (Quarters 1,2,3, and 4) 116 Liquid Effluents Batch Release Summary Unit 2 (Quarters 1,2,3, and 4) 117 Liquid Effluents Batch Release Summary Site (Quarters 1,2,3, and 4) 118 Liquid Effluents Abnormal Release Summary Unit I (Quarters 1,2,3, and 4) 119 Liquid Effluents Abnormal Release Summary Unit I (Quarters 1,2,3, and 4) 121 Liquid Effluents Abnormal Release Summary Site (Quarters 1,2,3, and 4) 122 Gaseous Effluents 123 Regulatory Requirements 123 Dose Rate Limits 123 Air Doses Due to Noble Gases in Gaseous Releases 123 Page 87 of 503 2.1.3 2.2 2.2.1 2.2.2 2.2.2.1 2.2.2.2 2.2.2.3 2.2.3 2.3 2.4 2.5 2.6 Table 2-IA Table 2-1 B Table 2-I C Table 2-2A Table 2-2B Doses to a Member of the Public 123 Measurements and Approximations of Total Radioactivity 124 Sample Collection and Analysis 124 Total Quantities of Radioactivity, Dose Rates, and Cumulative Doses 125 Fission and Activation Gases 125 Radioiodines, Tritium and Particulate Releases 125 Gross Alpha Release 125 Total Error Estimation 126 Gaseous Effluent Release Data 127 Radiological Impact Due to Gaseous Releases 128 Gaseous Effluents | |||
-Batch Releases 128 Gaseous Effluents -Abnormal Releases 128 Gaseous Effluents Summation of All Releases Unit 1 (Quarters 1,2,3, and 4) 129 Gaseous Effluents Summation of All Releases Unit 2 (Quarters 1,2,3, and 4) 130 Gaseous Effluents Summation of All Releases Site (Quarters 1,2,3, and 4) 131 Gaseous Effluents Mixed Mode Releases Unit I (Quarters 1,2,3, and 4) 133 Gaseous Effluents Mixed Mode Releases Unit 2 (Quarters 1,2,3, and 4) 136 Page 88 of 503 Table 2-2C Table 2-3A Table 2-3B Table 2-3C Table 2-4A Table 2-4B Table 2-4C Table 2-5A Table 2-5B Table 2-5C Table 2-6 Table 2-7A Gaseous Effluents Mixed Mode Releases Site (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit I (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Minimum Detectable Concentrations | |||
-Gaseous Gaseous Effluents | |||
-Batch Release Summary Unit 1 (Quarters 1,2,3, and 4)139 142 145 148 150 151 152 153 154 155 157 158 Page 89 of 503 Table 2-7B Table 2-7C Table 2-8A Table 2-8B Table 2-8C 3.0 3.1 3.1.1 3.1.2 3.2 Table 3-1 4.0 4.1 4.2 Table 4-1 5.0 5.1 5.2 Gaseous Effluents | |||
-Batch Release Summary Unit 2 (Quarters 1,2,3, and 4) 159 Gaseous Effluents | |||
-Batch Release Summary Site (Quarters 1,2,3, and 4) 160 Gaseous Effluents -Abnormal Release Summary Unit I (Quarters 1,2,3, and 4) 161 Gaseous Effluents | |||
-Abnormal Release Summary Unit 2 (Quarters 1,2,3, and 4) 162 Gaseous Effluents | |||
-Abnormal Release Summary Site (Quarters 1,2,3, and 4) 163 Solid Waste 164 Regulatory Requirements 164 Solid Radioactive Waste System 164 Reporting Requirements 164 Solid Waste Data 164 Solid Waste and Irradiated Fuel Shipments 165 Doses to Members of the Public Inside the Site Boundary 175 Regulatory Requirements 176 Demonstration of Compliance 176 Doses to Members of the Public Due to Activities Inside the Site Boundary 79 Total Dose from Uranium Fuel Cycle (40CFR190) 180 Regulatory Requirements 180 Demonstration of Compliance 180 Page 90 of 503 6.0 7.0 7.1 7.1.1 7.1.2 7.2 7.2.1 7.2.2 8.0 8.1 8.2 9.0 9.1 9.2 Appendix A Appendix B Appendix C Meteorological Data Program Deviations Inoperable Liquid or Gaseous Effluent Monitoring Instrumentation Regulatory Requirement Description of Deviations Tanks Exceeding Curie Content Limits Regulatory Requirements Description of Deviations Changes to the Vogtle Electric Generating Plant Offsite Dose Calculation Manual (ODCM)Regulatory Requirements Description of Changes Major Changes to Liquid, Gaseous, or Solid Radwaste Treatment Systems Regulatory Requirements Description of Major Changes Carbon-1 4 Corrected Reports VEGP ODCM Version 29 180 180 180 180 181 182 182 182 182 182 183 183 183 184 185 185 91 Page 91 of 503 | |||
===1.0 Liquid=== | |||
Effluents 1.1 Regulatory Requirements | |||
====1.1.1 Concentration==== | |||
Limits In accordance with Technical Specification 5.5.4.b, the concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS shall be limited at all times to ten times the concentrations specified in 10 CFR 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 1 E-04 1 iCi/ml total activity.1.1.2 Dose Limits The dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive materials in liquid effluents released, from each unit, to UNRESTRICTED AREAS shall be limited as follows: a. During any calendar quarter to less than or equal to 1.5 mrems to the whole body and to less than or equal to 5 mrems to any organ, and b. During any calendar year to less than or equal to 3 mrems to the whole body and to less than or equal to 10 mrems to any organ.1.2 Effluent Concentration Limit (ECL)ECL values used for determining the allowable liquid radwaste release rates and concentrations for the principal gamma emitters, 1-131, tritium, Sr-89, Sr-90 and Fe-55 are taken from 10 CFR Part 20, Appendix B, Table 2, Column 2. A tolerance factor of up to 10 is utilized to allow flexibility in establishing practical monitor set points which can accommodate effluent releases at concentrations higher than the ECL values stated in 10 CFR 20, Appendix B, Table 2, Column 2.For dissolved or entrained noble gases in liquid radwaste, the ECL is 1 E-04 pCi/ml total activity.For gross alpha in liquid radwaste, the ECL is 2 E-09 ptCi/ml.For all the above radionuclides or categories of radioactivity, the overall ECL fraction is determined in accordance with 10 CFR Part 20, Appendix B. The method utilizing the ECL fraction to determine release rates and liquid radwaste effluent radiation monitor set points is described in Subsection 1.3 of this report.Page 92 of 503 1.3 1.3.1 Measurements and Approximations of Total Radioactivity Total Radioactivity Determination Prior to the release of any tank containing liquid radwaste, and following the required recirculation, samples are collected and analyzed in accordance with the Offsite Dose Calculation Manual (ODCM) Table 2-3"Radioactive Liquid Waste Sampling and Analysis Program". | |||
A sample from each tank which is planned for release is analyzed for principal gamma emitters, 1-131, and dissolved and entrained noble gases by gamma spectroscopy. | |||
Monthly and quarterly composites are prepared for analysis by extracting aliquots from each sample taken from the tanks, which are released. | |||
Liquid radwaste sample analyses are performed as follows: MEASUREMENT | |||
: 1. Gamma Isotopic 2. Dissolved or entrained noble gases 3. Tritium 4. Gross Alpha 5. Sr-89 & Sr-90 FREQUENCY Each Batch Each Batch Monthly Composite Monthly Composite Quarterly Composite METHOD Gamma Spectroscopy with computerized data reduction. | |||
Gamma Spectroscopy with computerized data reduction Distillation and liquid scintillation counting Gas flow proportional counting Chemical separation and gas flow proportional or scintillation counting Chemical separation and liquid scintillation counting 6. Fe-55 Quarterly Composite Page 93 of 503 | |||
====1.3.1 Total==== | |||
Radioactivity Determination cont'd Gamma isotopic measurements are performed using germanium detectors with a resolution of 2.1 keV or lower. A peak search of the resulting gamma ray spectrum is performed by the computer system. Energy and net count data for all significant peaks are determined, and a quantitative reduction or MDC calculation is performed. | |||
This ensures that the MDC's are met for the nuclides specified in ODCM Chapter 10 (i.e., Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-1 34, Cs-1 37, Ce-141 and Ce-144). The quantitative calculations, corrections for counting time, decay time, sample volume, sample geometry, detector efficiency, baseline counts, branching ratio and MDC calculations, are made based on the counts at the location in the spectrum where the peak for that radionuclide would be located, if present.Tritium, Gross Alpha, Sr-89, Sr-90, Fe-55 and Ni-63 are, in some cases, analyzed offsite.ECL fraction is determined using radionuclide concentrations of a tank planned for release, the most current results available for tritium, gross alpha, Sr-89, Sr-90, Fe-55 and Ni-63 and the corresponding ECL values.This ECL fraction is used, with appropriate safety factors, tolerance factors, and the minimum assured dilution stream flow to calculate maximum permissible release rates and a liquid effluent monitor setpoint. | |||
The monitor setpoint is calculated to assure that the limits of the Offsite Dose Calculation Manual (ODCM) are not exceeded.A monitor reading in excess of the calculated setpoint results in an automatic termination of the liquid radwaste discharge. | |||
Liquid effluent discharge is also automatically terminated if the dilution stream flow rate falls below the minimum assured dilution flow rate used in the setpoint calculations and established as a setpoint on the dilution stream flow monitor.Radionuclide concentrations, safety factors, dilution stream flow rate, and liquid effluent radiation monitor calibrations are entered into the computer and a pre-release printout is generated. | |||
If the release is not permissible, appropriate warnings will be displayed on the computer screen. If the release is permissible, it is approved by the Chemistry Department and sent to the Operations Department for approval and release. When the release is completed, the necessary data from the release (i.e., release volume, etc.) are provided by the Operations Department to the Chemistry Department. | |||
These data are input to the computer and a post-release printout is generated. | |||
The post release printout contains the actual release rates, release concentrations and quantities, actual dilution flow, and calculated doses to an individual. | |||
Typically achieved liquid effluent sample analyses minimum detectable concentrations are reported in Table 1-4.Page 94 of 503 | |||
====1.3.2 Total==== | |||
Error Estimation The total or maximum error associated with the effluent measurement includes the cumulative errors resulting from the total operation of sampling and measurement. | |||
Because it may be very difficult to assign error terms for each parameter affecting the final measurement, detailed statistical evaluation of error is not suggested. | |||
The objective should be to obtain an overall estimate of the error associated with measurements of radioactive materials released in effluents (Reference Reg. Guide 1.23 Rev 1). Total Error is calculated by the root mean square method. The root mean square value is the square root of the arithmetic mean (average) of the squares of the original values.a. Fission and activation total release was calculated from sample analysis results and release point flow rates.Sampling and statistical error 10%Counting Equipment Calibration 10%Tank Volumes and System Flow Rates 20%TOTAL ERROR 24.5%b. Total Tritium release was calculated from sample analysis results and release point volumes.Sampling and statistical errors 10%Counting equipment calibration 10%Tank volumes and system flow rate 20%TOTAL ERROR 24.5%c. Dissolved and entrained gases were calculated from sample analysis results and release point volumes.Sampling and statistical error 20%Counting equipment calibration 10%Tank volumes and system flow rate 20%TOTAL ERROR 30%d. Gross alpha radioactivity was calculated from sample analysis results and release point volumes.Sampling and statistical error 10%Counting Equipment calibration 10%Tank volumes and system flowrates 20%TOTAL ERROR 24.5%Page 95 of 503 | |||
====1.3.2 Total==== | |||
Error Estimation cont'd e. Volume of waste prior to dilution was calculated from level indicators on the tanks and pump discharge flow rates and times.Level Indicator error 10%Operator Interpretation of gauge 10%TOTAL ERROR 14%f. Volume of dilution water used was calculated from flow totalizers and pump discharge flow rates and times.Flow totalizer error 10%Operator interpretation of gauge 10%TOTAL ERROR 14%g. Gross alpha, Sr-89, Sr-90, Fe-55, Ni-63 and H-3 radioactivity has an additional error associated with sample compositing. | |||
Compositing sample error 5%1.4 Liquid Effluent Release Data Regulatory Guide 1.21 Rev. 1 Tables 2A and 2B are found in this report as Tables 1-1A, 1-1 B, 1-1 C, 1-2A, 1-2B and 1-2C. Data is presented on a quarterly basis as required by Regulatory Guide 1.21 Rev. 1 for all four quarters.1.5 Radiological Impact Due to Liquid Releases Doses to an individual due to radioactivity in liquid effluent were calculated in accordance with the Offsite Dose Calculation Manual.Results are presented in Table 1-3A for Unit 1 and 1-3B for Unit 2, for all four quarters.1.6 Liquid Effluents | |||
-Batch Releases Batch release information for liquid effluents is presented in Table 1-5A for Unit 1 and Table 1-5B for Unit 2.1.7 Liquid Effluents | |||
-Abnormal Releases There were no abnormal liquid releases during 2013.Page 96 of 503 Table 1-1A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents | |||
-Summation of All Releases Unit: 1 Starting: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Tyve of Effluent Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter A. Fission And Activation Products 1. Total Release (not including tritium, gases, alpha) Curies 8.92E-02 2.04E-02 1.66E-02 7.24E-03 2. Average diluted concentration during period uCi/mL 8.73E-09 5.78E-09 4.1OE-09 1.12E-09 3. Percent of Applicable Limit %* * * *B. Tritium 1. Total Release Curies 7.69E+02 4.33E+02 1.37E+02 3.41E+02 2. Average diluted Concentration during period uCi/mL 7.53E-05 1.22E-04 3.36E-05 5.26E-05 3. Percent of Applicable Umit %* * * *C. Dissolved and Entrained Gases 1. Total Release Curies 7.26E-03 4.18E-05 0.OOE+00 6.58E-06 2. Average diluted Concentration during period uCi/mL 7.11E-10 1.18E-11 0.OOE+00 1.02E-12 3. Percent of Applicable Limit %* * * *D: Gross Alpha Radioactivity | |||
: 1. Total Release Curies 4.81E-04 O.OOE+00 O.OOE+00 0.OOE+00 E: Waste Vol Release (Pre-Dilution) | |||
Liters 2.68E+07 2.95E+07 2.82E+07 3.14E+07 F. Volume of Dilution Water Used Liters 1.02E+10 3.50E+09 4.03E+09 6.44E+09* Applicable limits are expressed in terms of dose. See Tables 1-3A and 1-3B of this report.Page 97 of 503 If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 1-4 for typical minimum detectable concentrations. | |||
Page 98 of 503 Table 1-1B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents | |||
-Summation Of All Releases Unit: 2 Startina: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Type of Effluent A. Fission And Activation Products 1. Total Release (not including tritium, gases, alpha)2. Average diluted concentration during period 3. Percent of Applicable Limit Ilnii**I CT Mlmml4=r I)Mf fmm=lr*gr'ADf r% A M r AT- Monmmgr M Curies uCi/mL 1.21E-02 1.50E-09 8.18E-03 2.34E-09 2.71E-03 6.76E-10*¢1.94E-03 3.24E-10 B. Tritium 1. Total Release Curies 6.72E+01 6.95E+01 2. Average diluted Concentration during period uCi/mL 8.34E-06 1.99E-05 3. Percent of Applicable Limit %* *C. Dissolved and Entrained Gases 1. Total Release Curies 3.35E-04 5.13E-06 2. Average diluted Concentration during period uCi/mL 4.16E-11 1.47E-12 3. Percent of Applicable Limit %* *D: Gross Alpha Radioactivity | |||
: 1. Total Release Curies O.OOE+00 0.OOE+00 E: Waste Vol Release (Pre-Dilution) | |||
Liters 3.45E+07 4.55E+07 F. Volume of Dilution Water Used Liters 8.02E+09 3.44E+09* Applicable limits are expressed in terms of dose. See Tables 1-3A and 1-3B of this report.3.85E+01 9.59E-06 , O.OOE+00 O.OOE+00 0.OOE+00 4.18E+07 3.97E+09 4.70E+01 7.86E-06 O.OOE+OO O.OOE+0O O.OOE+OO 4.37E+07 5.94E+09 Page 99 of 503 If Not Detected,. | |||
Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 1-4 for typical minimum detectable concentrations. | |||
Page 100 of 503 Table 1-1C VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents | |||
-Summation Of All Releases Unit: Site Starting: | |||
1-Jan- 2013 Endinq: 31-Dec-2013 TvYe of Effluent Units 1ST Quarter 2ND Ouarter 3RD Ouarter 4TH Ouarter A. Fission And Activation Products 1. Total Release (not including tritium, gases, alpha) Curies 1.01E-01 2.86E-02 1.94E-02 9.18E-03 2. Average diluted concentration during period uCi/mL 5.54E-09 4.07E-09 2.40E-09 7.37E-10 3. Percent of Applicable Limit %* * * *B. Tritium 1. Total Release Curies 8.37E+02 5.02E+02 1.75E+02 3.88E+02 2. Average diluted Concentration during period uCi/mL 4.58E-05 7.15E-05 2.17E-05 3.11E-05 3. Percent of Applicable Limit % * * * *C. Dissolved and Entrained Gases 1. Total Release Curies 7.60E-03 4.70E-05 O.OOE+00 6.58E-06 2. Average diluted Concentration during period uCi/mL 4.16E-10 6.69E-12 O.OOE+00 5.29E-13 3. Percent of Applicable Limit % * * * *D: Gross Alpha Radioactivity | |||
: 1. Total Release Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 E: Waste Vol Release (Pre-Dilution) | |||
Liters 6.13E+07 7.50E+07 7.OOE+07 7.51E+07 F. Volume of Dilution Water Used Liters 1.82E+10 6.95E+09 8.OOE+09 1.24E+10* Applicable limits are expressed in terms of dose. See Tables 1-3A and 1-3B of this report.Page 101 of 503 If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 1-4 for typical minimum detectable concentrations. | |||
Table 1-2A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents Unit: 1 Startina: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Fission & Activation Products Fe-55 Total For Period Tritium H-3 Dissolved And Entrained Gases No Nuclides Found Gross Alpha Radioactivity No Nuclides Found Curies Curies Curies Curies Curies 1.09E-03 1.09E-03 3.18E-02 O.OOE+00 O.OOE+00 1.64E-03 1.64E-03 4.13E-02 O.OOE+O0 O.OOE+00 5.87E-04 5.87E-04 4.15E-02 O.OOE+00 O.OOE+00 3.76E-04 1.27E-01 0.OOE+00 0.OOE+00*Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable concentrations. | |||
Page 102 of 503 Table 1-2A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents Unit: 1 Starting: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released Fission & Activation Products Co-58 Co-60 Cr-51 Fe-55 1-131 1-132 Mn-54 Nb-95 Ni-56 Ni-63 Sr-89 Sr-90 W-187 Ba-133 Cs-134 Cs-137 Rh-105 Ru-105 Ru-106 Sb-122 Sb-124 Sb-125 Sb-126 Te-132 Sn-117M Te-125M Te-129M Total For Period Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies 5.69E-03 1.55E-03 7.33E-04 2.46E-02 9.94E-05 7.27E-05 3.64E-04 6.01E-06 9.91E-06 2.21E-03 2.09E-05 4.96E-06 O.OOE+00 6.72E-05 1.90E-05 2.48E-04 2.04E-05 4.81E-06 O.OOE+00 3.18E-05 6.17E-05 3.79E-02 3.79E-05 7.81E-05 O.OOE+00 1.36E-02 7.87E-04 8.81E-02 2.56E-03 6.43E-04 0.OOE+00 7.85E-03 0.OOE+0O 0.OOE+O0 1.83E-05 2.58E-06 O.OOE+00 6. 13E-03 1.66E-06 6.1 IE-07 7.26E-06 0.OOE+OO 4. 18E-05 4.36E-04 0.OOE+00 0.OOE+00 8.41E-06 0.OOE+0O 4-33E-06 5. 34E-04 0.OOE+00 0.OOE+00 0.OOE+O0 5.37E-04 0.OOE+00 1.88E-02 2.33E-03 6.09E-04 0.OOE+0O 4.30E-03 0.OOE+00 0.OOE+00 3.48E-05 0.OOE+00 0.OOE+00 4.69E-03 9.36E-07 1 .47E-06 0.OOE+00 0.OOE+00 4. 57E-05 3.34E-04 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 1. 16E-03 0.OOE+O0 0.OOE+00 0.OOE+O0 2.57E-03 0.OOE+O0 1.61E-02 2.03E-04 6.04E-04 0.OOE+00 8.38E-04 0.OOE+00 0.OOE+00 1.06E-05 0.OOE+00 8.40E-06 7.93E-04 0. OOE+00 2.64E-07 0.OOE+00 0.OOE+0O 1.49E-06 1.14E-04 O.OOE+00 O.OOE+00 O.OOE+0O 0.OOE+0O 0.OOE+00 3.84E-05 0.OOE+OO 0.OOE+0O 1.66E-06 4.25E-03 0.OOE+00 6.86E-03*Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable Page 103 of 503 concentrations. | |||
Page 104 of 503 Table 1-2A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents Unit: 1 Startinga: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Batch Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Nuclides Released Tritium H-3 Dissolved And Entrained Gases Ar-41 Xe-127 Xe-133 Xe-135 Xe-133M Total For Period Gross Alpha Radioactivity G-Alpha Curies Curies Curies Curies Curies Curies Curies 7.69E+02 O.OOE+00 1.06E-05 6.73E-03 4.71E-04 5.53E-05 7.26E-03 4.33E+02 3. 19E-06 0.OOE+00 3.86E-05 0.OOE+00 0.OOE+00 4.18E-O5 1.37E+02 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 3.41E+02 0.OOE+00 0.OOE+O0 6.58E-06 0.OOE+00 a.OOE+00 6.5SE-06 Curies O.OOE+O0 O.OOE+00 O.OOE+O0 O.OOE+00 Page 105 of 503 | |||
*Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 1-4 for typical minimum detectable concentrations. | |||
Table 1-2B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents Unit: 2 Startina: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Continuous Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Nuclides Released Fission & Activation Products No Nuclides Found Tritium H-3 Dissolved And Entrained Gases No Nuclides Found Gross Alpha Radioactivity No Nuclides Found Curies Curies Curies Curies 0.OOE+00 3.88E-02 0.OOE+00 0.OOE+00 0.OOE+00 1.17E-01 0.OOE+00 0.OOE+00 0.OOE+00 2.92E-02 0.OOE+00 0.OOE+00 O.OOE+00 7.56E-02 O.OOE+00 O.OOE+00 Page 106 of 503 | |||
*Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 1-4 for typical minimum detectable concentrations. | |||
Table 1-2B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents Unit: 2 Startina: | |||
1-Jan- 2013 Endinq: 31-Dec-2013 Batch Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Nuclides Released Fission & Activation Products Co-58 Co-60 Cr-51 Fe-55 1-131 Mn-54 Nb-95 Ni-56 Ni-63 Sr-89 W-187 Cs-134 Cs-137 Sb-122 Sb-124 Sb-125 Sb-126 Te-132 Te-125M Te-129M Total For Period Tritium H-3 Dissolved And Entrained Gases Ar-41 Xe-127 Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies 1.12E-03 4.35E-04 1.04E-04 1.28E-03 1.65E-05 4.99E-05 0.OOE+00 7.27E-06 8.73E-04 5.49E-06 0.OOE+00 0.OOE+00 7.08E-05 5.62E-06 3.47E-05 4.87E-03 9.55E-06 5.28E-06 3.09E-03 8.88E-05 1.21E-02 6.71E+01 O.OOE+00 1.06E-05 1.57E-03 6.04E-04 0.OOE+00 1.37E-03 0.OOE+00 3.30E-05 1.24E-05 0.OOE+00 1. 12E-03 5.92E-06 6. 17E-06 2.25E-04 8.29E-04 0.OOE+00 0.OOE+00 5.OOE-04 0.OOE+00 0.OOE+00 1.91E-03 0.OOE+0O 8.18E-03 6.94E+01 5. 13E-06 0.OQE+00 4.96E-04 2. 16E-04 0.OOE+00 5.96E-06 0.OOE+00 1.05E-06 0.OOE+O0 8.57E-07 2.0 1E-04 0.OOE+00 0.OOE+00 2.74E-05 1.42E-04 0.OOE+00 9.98E-06 8.99E-04 0.OOE+00 0.OOE+00 7.15E-04 0.OOE+00 2.71E-03 3.85E+01 0.OOE+0Q 0.OOE+00 4.03E-05 6.37E-05 0.OOE+O0 1. 15E-04 0.OOE+00 0.OOE+00 O.OOE+00 2.40E-06 6.41E-05 0.OOE+O0 0.OOE+00 1.57E-06 2.39E-05 0.OOE+00 0.OOE+00 1.11E-05 0.OOE+00 0.OOE+00 1.62E-03 0.OOE+O0 IL.94E-03 4. 70E+01 0.OOE+00 0.OOE+O0 Page 107 of 503 Xe-133 Curies 3.23E-04 O.OOE+00 O.OOE+00 O.OOE+00 Xe-135 Curies 1.77E-06 O.OOE+00 O.OOE+00 O.OOE+00 Total For Period Curies 3.35E-04 5.13E-06 O.OOE+00 0.OOE+00 Gross Alpha Radioactivity No Nuclides Found Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00*Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable concentrations. | |||
Table 1-2C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents Unit: Site Starting: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Continuous Mode Nuclides Released Fission & Activation Products Fe-55 Total For Period Tritium H-3 Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Curies Curies Curies 1.09E-03 7.06E-02 1.64E-03 1.58E-01 5.87E-04 7.07E-02 3.76E-04 2.02E-01 Dissolved And Entrained Gases No Nuclides Found Gross Alpha Radioactivity No Nuclides Found Curies Curies 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 Page 108 of 503 | |||
*Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable concentrations. | |||
Table 1-2C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents Unit: Site Startina: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Fission & Activation Products Co-58 Curies 6.81E-03 4.12E-03 2.82E-03 2.43E-04 Co-60 Curies 1.98E-03 1.25E-03 8.25E-04 6.67E-04 Cr-51 Curies 8.37E-04 O.OOE+00 O.00E+00 O.OOE+00 Fe-55 Curies 2.58E-02 9.22E-03 4.31E-03 9.53E-04 1-131 Curies 1.16E-04 O.OOE+00 O.OOE+00 O.OOE+00 1-132 Curies 7.27E-05 O.OOE+00 O.OOE+00 O.OOE+00 Mn-54 Curies 4.14E-04 5.12E-05 3.59E-05 1.06E-05 Nb-95 Curies 6.01E-06 1.49E-05 0.O0E+00 0.OOE+00 Ni-56 Curies 1.72E-05 O.OOE+00 8.57E-07 1.08E-05 Ni-63 Curies 3.08E-03 7.25E-03 4.89E-03 8.57E-04 Sr-89 Curies 2.64E-05 7.58E-06 9.36E-07 0.OOE+00 Sr-90 Curies 4.96E-06 6.11E-07 1.47E-06 2.64E-07 W-187 Curies O.OOE+00 1.34E-05 O.OOE+00 0.OOE+00 Ba-133 Curies 6.72E-05 O.OOE+00 O.OOE+00 O.OOE+00 Cs-134 Curies 1.90E-05 2.67E-04 7.31E-05 3.05E-06 Cs-137 Curies 3.19E-04 1.27E-03 4.75E-04 1.38E-04 Rh-105 Curies 2.04E-05 O.OOE+00 O.OOE+00 O.OOE+00 Ru-105 Curies 4.81E-06 O.OOE+00 O.OOE+00 0.OOE+00 Ru-106 Curies 0.OOE+00 8.41E-06 0.OOE+00 O.OOE+00 Sb-122 Curies 3.74E-05 0.OOE+00 0.OOE+00 O.OOE+00 Sb-124 Curies 9.65E-05 4.33E-06 9.98E-06 O.OOE+00 Sb-125 Curies 4.28E-02 1.03E-03 2.05E-03 4.95E-05 Page 109 of 503 Sb-126 Curies 4.74E-05 0.OOE+00 O.OOE+00 0.OOE+00 Te-132 Curies 8.34E-05 0.OOE+00 O.OOE+00 O.OOE+00 Sn-117M Curies O.OOE+00 0.OOE+00 0.OOE+00 1.66E-06 Te-125M Curies 1.66E-02 2.45E-03 3.28E-03 5.87E-03 Te-129M Curies 8.75E-04 O.OOE+00 0.OOE+00 O.OOE+00 Total For Period Curies 1.OOE-01 2.70E-02 1.88E-02 8.80E-03*Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable concentrations. | |||
Table 1-2C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents Unit: Site Startinag 1-Jan- 2013 Endina: 31-Dec-2013 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Tritium H-3 Curies 8.37E+02 5.02E+02 1.75E+02 3.87E+02 Dissolved And Entrained Gases Ar-41 Curies O.OOE+00 8.32E-06 O.OOE+00 0.OOE+00 Xe-127 Curies 2.12E-05 O.OOE+00 O.OOE+00 0.OOE+00 Xe-133 Curies 7.05E-03 3.86E-05 O.OOE+00 6.58E-06 Xe-135 Curies 4.73E-04 0.OOE+00 O.OOE+00 0.OOE+00 Xe-133M Curies 5.53E-05 O.OOE+00 0.OOE+00 O.OOE+00 Total For Period Curies 7.60E-03 4.70E-05 0.OOE+00 6.58E-06 Gross Alpha Radioactivity G-Alpha Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Page 110 of 503 | |||
*Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable concentrations. | |||
Table 1-3A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses to a member of the public due to Liquid Releases Unit: 1 Startina: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Liver Lung Thyroid Total Body ODCM Lmt 5.OOE+O0 5.OOE+O0 5.OOE+O0 5.OOE+O0 5.OOE+O0 5.OOE+O0 1.50E+00 Units mRem mRem mRem mRem mRem mRem mRem 1ST Qtr 3.09E-03 1.75E-02 1.38E-02 1.33E-02 5.61E-02 1. 15E-02 1.26E-02%/o ODCM 6.18E-02 3.51E-01 2.76E-01 2.66E-01 1.12E+00 2.31E-01 8.42E-01 2ND Qtr 8.21E-03 1.34E-02 1.46E-02 1.87E-02 1.45E-02 1.28E-02 1.66E-02%/o ODCM 1.64E-01 2.68E-01 2.93E-01 3.73E-01 2.90E-01 2.55E-01 1.11E+00 3RD Qtr 6.16E-03 4.47E-03 5.38E-03 8.12E-03 6.88E-03 3.34E-03 6.51E-03%/a ODCM 1.23E-01 8.94E-02 1.08E-01 1.62E-01 1.38E-01 6.69E-02 4.34E-01 4TH Qtr 1.60E-03 9.57E-03 9.85E-03 9.97E-03 8.92E-03 8.73E-03 9.51E-03 0/a ODCM 3.19E-02 1.91E-01 1.97E-01 1.99E-01 1.78E-01 1.75E-01 6.34E-0 1 Cumulative Doses per Year Organ ODCM Lmt Units 1.OOE+01 mRem 1.00E+01 mRem Year to Ending Date% ODCM Receptor Limit Bone GI-Lli 1.91E-02 4.49E-02 1.91E-01 Maximum Individual Liquid 4.49E-01 Maximum Individual Liquid Liquid Effluent Organ Annual Liquid Effluent Organ Annual Page 11 of 503 Kidney Liver Lung Thyroid Total Body 1.00E+01 1.00E+01 1.00E+01 1.0OE+01 3.OOE+00 mRem mRem mRem mRem mRem 4.37E-02 5.01E-02 8.64E-02 3.64E-02 4.53E-02 4.37E-01 5.01E-01 8.64E-01 3.64E-01 1.51E+00 Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual Uquid Effluent TB Annual Page 112 of 503 Table 1-3B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses to a member of the public due to Liquid Releases Unit: 2 Startina: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Liver Lung Thyroid Total Body ODCM Lint Units 1ST Qtr 0/b ODCM 2ND Qtr % ODCM 3RD Qtr %/o ODCM 4TH Qtr % ODCM 5.OOE+00 5.OOE+00 5.OOE+00 5.OOE+00 5.OOE+00 5.OOE+00 1.50E+00 mRem mRem mRem mRem mRem mRem mRem 7.11E-04 1.82E-03 1.38E-03 1.33E-03 6.51E-03 9.41E-04 1. 18E-03 1.42E-02 3.63E-02 2.76E-02 2.66E-02 1.30E-01 1.88E-02 7.87E-02 9.40E-03 3.23E-03 7.03E-03 1.50E-02 4.66E-03 2.04E-03 1. 1OE-02 1.88E-01 6.46E-02 1.41E-01 3.OOE-01 9.32E-02 4.07E-02 7.35E-01 1.65E-03 1.53E-03 1.96E-03 3.29E-03 3.84E-03 1. 1OE-03 2.61E-03 3.29E-02 3.07E-02 3.91E-02 6.59E-02 7.68E-02 2.20E-02 1.74E-01 3.44E-04 1.70E-03 1.79E-03 1.67E-03 1.40E-03 1.36E-03 1.55E-03 6.88E-03 3.40E-02 3.57E-02 3.34E-02 2.80E-02 2.72E-02 1.03E-01 Cumulative Doses per Year Organ ODCM Lmt Units Year to Ending Date%/a ODCM Receptor Limit Bone GI-Lli Kidney Uver Lung Thyroid Total Body 1.00E+01 1.00E+01 1.OOE+01 1.00E+01 1.00E+01 1.00E+01 3.OOE+00 mRem mRem mRem mRem mRem mRem mRem 1.21E-02 8.28E-03 1.21E-02 2.13E-02 1.64E-02 5.44E-03 1.64E-02 1.21E-01 8.28E-02 1.21E-01 2.13E-01 1.64E-01 5.44E-02 5.45E-01 Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual ULquid Maximum Individual ULquid Maximum Individual Liquid ULquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual ULquid Effluent Organ Annual ULquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent TB Annual Page 113 of 503 Table 1-3C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses to a member of the public due to Liquid Releases Unit: Site Starting: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Liver Lung Thyroid Total Body ODCM Lmt Units 1ST Qtr % ODCM 2ND Qtr %/o ODCM 3RD Qtr 0/o ODCM 4TH Qtr 0/b ODCM 5.OOE+00 5.OOE+00 5.0OEO00 5.OOE+00 5.OOE+OO 5.OOE+QO 1.50E+00 mRem mRem mRem mRem mRem mRem mRem 3.80E-03 1.94E-02 1.52E-02 1.47E-02 6.26E-02 1.25E-02 1.38E-02 7.61E-02 3.87E-01 3.04E-01 2.93E-01 1.25E+00 2.49E-01 9.21E-01 1.76E-02 1.66E-02 2.17E-02 3.36E-02 1.92E-02 1.48E-02 2.77E-02 3.52E-01 3.32E-01 4.33E-01 6.73E-01 3.84E-01 2.96E-01 1.84E+00 7.81E-03 6.OOE-03 7.34E-03 1.14E-02 1.07E-02 4.44E-03 9.12E-03 1.56E-01 1.20E-01 1.47E-01 2.28E-01 2. 14E-01 8.89E-02 6.08E-01 1.94E-03 1. 13E-02 1. 16E-02 1. 16E-02 1.03E-02 1.01E-02 1.11E-02 3.88E-02 2.25E-01 2.33E-01 2.33E-01 2.06E-0 1 2.02E-01 7.37E-01 Cumulative Doses per Year Organ ODCM Lmt Units Year to Ending Date% ODCM Receptor Limit Bone GI-Lli Kidney Liver Lung Thyroid Total Body 1.OOE+O1 1.OOE+01 1.0OE+01 1.OOE+O1 1.OOE+01 1.OOE+O1 3.OOE+00 mRem mRem mRem mRem mRem mRem mRem 3.12E-02 5.32E-02 5.58E-02 7.14E-02 1.03E-01 4.18E-02 6.16E-02 3.12E-01 5.32E-01 5.58E-01 7.14E-01 1.03E+00 4.18E-01 2.05E+00 Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent TB Annual Page 114 of 503 Table 1-4 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 MINIMUM DETECTABLE CONCENTRATIONS-LIQUID SAMPLE ANALYSES Starting: | |||
1-Jan-2013 Ending: 31-Dec-2013 The values in this table represent a priori Minimum Detectable Concentrations (MDC) that are typically achieved in laboratory analyses of liquid radwaste samples.RADIONUCLIDE Mn-54 Fe-59 Co-58 Co-60 Zn-65 Mo-99 Cs-134 Cs-137 Ce-141 Ce-144 1-131 Xe-133 Xe-135 Fe-55 Sr-89 Sr-90 H-3 Gross Alpha MDC 2.73E-08 8.33E-08 3.78E-08 6.76E-08 1.32E-07 4.31E-07 3.06E-08 4.51E-08 6.99E-08 2.95E-07 5.97E-08 9.11E-08 4.27E-08 1.00E-06 5.OOE-08 7.OOE-09 2.OOE-06 7.OOE-08 UNITS pCi/ml 1 tCi/ml pCi/ml jiCi/ml tCi/ml iCi/ml ,tCi/ml pCi/ml pCi/ml 1Ci/ml tCi/ml 1 Ci/ml pCi/ml tCi/ml pCi/ml tCi/mI pCi/ml pCi/ml Page 115 of 503 Table 1-5A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents | |||
-Batch Release Summary Unit: 1 Startina: | |||
1-Jan- 2013 Ending: 31 -Dec-2013 Liquid Release Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter Year Totals 1. Number of batch releases 43 22 12 18 95 2. Total time period for Batch releases (Minutes) 1.52E+04 3.80E+03 1.58E+03 6.25E+03 2.68E+04 3. Maximum time period for a batch release (Minutes) 1.08E+03 6.08E+02 3.41E+02 9.08E+02 1.08E+03 4. Average time period for a batch release (Minutes) 3.53E+02 1.73E+02 1.31E+02 3.47E+02 2.82E+02 5. Minimum time period for a batch release (Minutes) 6.50E+01 6.10E+01 4.90E+01 6.OOE+01 4.90E+01 6. Average stream flow during periods of release of liquid effluent into a flowing stream * (CFS) 5863 6705 17736 7121 9356*Average river flowrate taken from USGS Monitoring Station 02197500, Savannah River at Burton's Ferry Bridge near Millhaven, Ga. 32 miles downstream of Plant Vogtle.Page 116 of 503 Table 1-5B i ; ;A n i I"n;4**t4UJ .ij fl~.~UC~a | |||
.* *Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents | |||
-Batch Release Summary Unit: 2 Startina" 1-Jan- 2013 Ending: 31-Dec-2013 1ST Quarter 2ND Quarter 3RD Quarter 15 18 7 es) 2.76E+03 2.96E+03 9.OOE+02 es) 7.60E+02 3.48E+02 2.83E+02 es) 1.84E+02 1.64E+02 1.29E+02 tes) 5.20E+01 4.70E+01 6.OOE+01 4TH Quarter 1. Number of batch releases 2. Total time period for Batch releases 3. Maximum time period for a batch release 4. Average time period for a batch release 5. Minimum time period for a batch release 6. Average stream flow during periods of release of liquid effluent into a flowing stream *(Minut (Minut (Minut ( Minut 6 1.21E+03 4.41E+02 2.02E+02 8.40E+01 7121 Year Totals 46 7.16E+03 7.60E+02 1.70E+02 4.70E+01 9356 ( CFS )5863 6705 17736*Average river flowrate taken from USGS Monitoring Station 02197500, Savannah River at Burton's Ferry Bridge near Millhaven, Ga. 32 miles downstream of Plant Vogtle.Page 117 of 503 Table 1-5C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents | |||
-Batch Release Summary Unit: Site Startina: | |||
1-Jan- 2013 Ending: 31-Dec-2013 I ;n..;A D0M ec IIn;i*I CT NimbrM Tin% fmm:rigr'A F' rlmm or 1. Number of batch releases 2. Total time period for Batch releases 3. Maximum time period for a batch release 4. Average time period for a batch release 5. Minimum time period for a batch release 6. Average stream flow during periods of release of liquid effluent into a flowing stream *(Minutes)(Minutes)(Minutes)(Minutes)(CFS )55 1.73E+04 1.08E+03 3.14E+02 5.20E+01 5863 40 6.75E+03 6.08E+02 1.69E+02 4.70E+01 6705 19 2.48E+03 3.41E+02 1.30E+02 4.90E+01 17736 4TH Ouarter 24 7.46E+03 9.08E+02 3.11E+02 6.OOE+01 7121 Year Totals 138 3.40E+04 1.08E+03 2.46E+02 4.70E+01 9356*Average river flowrate taken from USGS Monitoring Station 02197500, Savannah River at Burton's Ferry Bridge near Millhaven, Ga. 32 miles downstream of Plant Vogtle.Page 118 of 503 Table 1-6A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents | |||
-Abnormal Release Summary Unit: 1 Startina: | |||
1-]an- 2013 Ending: 31-Dec-2013 I in,,irl Ilnitc I QT nfrtar?NIl f.lmirher 2ND n"n er a 1. Number of Releases 2. Total Time For All Releases 3. Maximum Time For A Release 4. Average Time For A Release 5. Minimum Time For A Release 6. Total activity for all releases (Minutes)(Minutes)(Minutes)(Minutes)( Curies )0 0.OOE÷00 0.OOE+00 0.OOE+00 0.OOE+OO 0.OOE+00 0 O.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 3RD Ouarter 0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 4TH Ouarter 0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Year Totals 0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00*Average river flowrate taken from USGS Monitoring Station 02197500, Savannah River at Burton's Ferry Bridge near Millhaven, Ga. 32 miles downstream of Plant Vogtle.Page 119 of 503 Page 120 of 503 Table 1-6B VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents | |||
-Abnormal Release Summary Unit: 2 Startina: | |||
1-Jan- 2013 Endinn: 31-Dec-2013 Liouid Releases Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter Year Totals 1. Number of Releases 0 0 0 0 0 2. Total Time For All Releases (Minutes) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3. Maximum Time For A Release (Minutes) 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 4. Average Time For A Release (Minutes) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5. Minimum Time For A Release (Minutes) 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6. Total activity for all releases (Curies) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00*Average river flowrate taken from USGS Monitoring Station 02197500, Savannah River at Burton's Ferry Bridge near Millhaven, Ga. 32 miles downstream of Plant Vogtle.Page 121 of 503 Table 1-6C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents | |||
-Abnormal Release Summary Unit: Site Startina: | |||
1-lan- 2013 Endina: 31-Dec-2013 l .;Annmi D I I n;#-I CT Ml.m m ýr ,11n fmm=r+A'40n nm 1. Number of Releases 2. Total Time For All Releases 3. Maximum Time For A Release 4. Average Time For A Release 5. Minimum Time For A Release 6. Total activity for all releases (Minutes)(Minutes)(Minutes)(Minutes)( Curies )0 0.OOE+00 O.OOE+00 0.OOE+00 0.O0E+00 0.aOE+00 0 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+0O 0.OOE+00 0 0.OOE+00 0.OOE+O0 0.OOE+00 O.OOE+00 0.OOE+00 4TH Ouarter 0 0.OOE+00 0.OOE+0O 0.OOE+00 O.OOE÷0O 0.OOE+00 Year Totals 0 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+0O0 O.OOE+00*Average river flowrate taken from USGS Monitoring Station 02197500, Savannah River at Burton's Ferry Bridge near Millhaven, Ga. 32 miles downstream of Plant Vogtle.Page 122 of 503 | |||
===2.0 Gaseous=== | |||
Effluents 2.1 Regulatory Requirements The ODCM Specifications presented in this section are for Unit 1 and Unit 2.2.1.1 Dose Rate Limits The dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the SITE BOUNDARY shall be limited to the following: | |||
: a. For noble gases, Less than or equal to 500 mrems/yr. | |||
to the whole body and less than or equal to 3000 mrems/yr. | |||
to the skin and, b. For Iodine-1 31, for Iodine-1 33, for tritium and for all radionuclides in particulate form with half lives greater than 8 days: Less than or equal to 1500 mrems/yr. | |||
to any organ.2.1.2 Air Doses Due to Noble Gases in Gaseous Releases The air dose due to noble gases released in gaseous effluents, from each unit, to areas at and beyond the SITE BOUNDARY shall be limited to the following: | |||
: a. During any calendar quarter: Less than or equal to 5 mrads for gamma radiation and less than or equal to 10 mrads for beta radiation, and b. During any calendar year: Less than or equal to 10 mrads for gamma radiation and less than or equal to 20 mrads for beta radiation. | |||
====2.1.3 Doses==== | |||
to a Member of the Public The dose to a MEMBER OF THE PUBLIC from Iodine-131, Iodine-133, tritium and all radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents released, from each unit, to areas at and beyond the SITE BOUNDARY shall be limited to the following. | |||
: a. During any calendar quarter: Less than or equal to 7.5 mrems to any organ.b. During any calendar year: Less than or equal to 15 mrems to any organ.Page 123 of 503 | |||
===2.2 Measurements=== | |||
and Approximations of Total Radioactivity | |||
====2.2.1 Sample==== | |||
Collection and Analysis Gaseous Effluents at the Vogtle Electric Generating Plant are currently confined to five paths: plant vents (Unit 1 and Unit 2), the condenser air ejector, the steam packing exhauster systems (Unit 1 and Unit 2), and the Radwaste Processing Facility (RPF).Waste gas decay tanks are batch released through the Unit 1 plant vent. The containment purges are released through their respective plant vents.Containment atmosphere is also released via the containment equipment hatch during periods when the equipment hatch is open with containment purge/vent being stopped. Approval was granted by the NRC to open the equipment hatch during fuel movement; a release permit is generated when the equipment hatch is opened and the containment exhaust fan is not discharging to the plant vent.Any detected activity in the containment equipment hatch permit is included in the Ground Release Table of the effluent report.All of the paths with the exception of the RPF can be continuously monitored for gaseous radioactivity. | |||
The RPF is equipped with an integrated-type sample collection device for collecting particulates. | |||
Plant vent, containment, steam jet air ejector, steam-packing exhauster are equipped with an integrated-type sample collection device for collecting particulates and iodines. During this reporting period, there were no continuous radioactive releases through the condenser air ejector and the steam packing exhauster system vents. Batch Waste Gas Decay Tank releases are analyzed for noble gases before each release. The containment atmosphere is analyzed for noble gases prior to each release and for tritium at least on a monthly basis.Sample analysis results and release flow rates form the basis for calculating released quantities of radionuclide specific radioactivity, dose rates associated with gaseous releases, and cumulative doses for the current quarter and year.With each release period and batch release, radioactivity, dose rates, and cumulative doses are calculated. | |||
Cumulative dose results are tabulated, along with the percent of the ODCM limits for each release for the current quarter and year.Typically achieved minimum detectable concentrations for gaseous effluent sample analyses are reported in Table 2-6.Page 124 of 503 | |||
====2.2.2 Total==== | |||
Quantities of Radioactivity, Dose Rates, and Cumulative Doses The methods for determining release quantities of radioactivity, dose rates, and cumulative doses are as follows: 2.2.2.1 Fission and Activation Gases The released radioactivity is determined from sample analysis results collected as described above and average release flow rates over the period represented by the collected sample. Dose rates due to noble gases, radioiodines, tritium, and particulates are calculated. | |||
Calculated dose rates are compared to the dose rate limits specified in ODCM 3.1.2 for noble gases, radioiodines, tritium, and particulates. | |||
Dose rate calculation methodology is presented in the ODCM.Beta and gamma air doses due to noble gases are calculated for the location in the unrestricted area with the potential for the highest exposure due to gaseous releases. | |||
Air doses are calculated for each release period and cumulative totals are kept for each unit for the calendar quarter and year. Cumulative air doses are compared with the dose limits specified in ODCM 3.1.3. Current percent of the ODCM limits are shown on the printout for each release period. Air dose calculation methodology is presented in the ODCM.2.2.2.2 Radioiodines, Tritium and Particulate Releases The released quantities of radioiodines, tritium and particulates are determined using the weekly samples and release flow rates for the two plant vent release points.After each quarter, the particulate filters from each plant vent are combined, for strontium analysis. | |||
Strontium concentrations are input to the composite file of the computer to be used for release dose rate and individual dose calculations. | |||
Doses to a Member of the Public due to radioiodines, tritium and particulates are calculated for the controlling receptor, which is described in Table 3-7of the ODCM. Doses are calculated for each release period, and cumulative totals are kept for each unit for the current calendar quarter and year. Cumulative doses are compared to the dose limits specified in ODCM 3.1.4.Current percent of ODCM limits are shown in this report for each release period.2.2.2.3 Gross Alpha Release The gross alpha release is calculated each month by counting the particulate filters for each week for gross alpha activity. | |||
The four or five weeks' numbers are then recorded on a data sheet and the activity is summed at the end of the month. This concentration is used for release calculations. | |||
Page 125 of 503 | |||
====2.2.3 Total==== | |||
Error Estimation The total or maximum error associated with the effluent measurement will include the cumulative errors resulting from the total operation of sampling and measurement. | |||
Because it may be very difficult to assign error terms for each parameter affecting the final measurement, detailed statistical evaluation of error are not suggested. | |||
The objective should be to obtain an overall estimate of the error associated with measurements of radioactive materials released in liquid and gaseous effluents and solid waste.Estimated errors are based on errors in counting equipment calibration, counting statistics, vent-flow rates, vent sample flow rates, non-steady release rates, chemical yield factors, and sample losses for such items as charcoal cartridges. | |||
Total Error is calculated by the root mean square method. The root mean square value is the square root of the arithmetic mean (average) of the squares of the original values.a. Fission and activation total release was calculated from sample analysis results and release point flow rates.Sampling and statistical error in counting 10%Counting equipment calibration 10%Vent flow Rates 10%Non-steady release rates 20%TOTAL ERROR 26.5%b. 1-131 releases were calculated from each weekly sample: Statistical error in counting 10%Counting equipment calibration 10%Vent Flow Rates 10%Vent Sample Flow Rates 50%Non-Steady release rates 10%Losses from charcoal cartridges 10%TOTAL ERROR 55%c. Particulates with half-lives greater than 8 day releases were calculated from sample and analysis results and release point flow rates.Statistical error at MDC concentration 10%Counting equipment calibration 10%Vent flow rates 10%Vent sample flow rates 50%Non steady release rates 10%TOTAL ERROR 54%Page 126 of 503 | |||
====2.2.3 Total==== | |||
Error Estimation cont'd d. Total tritium releases were calculated from sample analysis results and release point flow rates.Water vapor in sample stream determination 10%Vent flow rates 10%Counting calibration and statistics 10%Non-steady release rates 10%TOTAL ERROR 20%e. Gross Alpha radioactivity was calculated from sample analysis results and release point flow rates.Statistical error at MDC concentration 10%Counting equipment calibration 10%Vent flow rates 10%Vent sample flow rates 50%Non Steady release rates 10%TOTAL ERROR 55%2.3 Gaseous Effluent Release Data Regulatory Guide 1.21 Rev. 1 Tables 1A, 1B, and 1C are found in this report as Tables 2-1A, 2-1B, 2-1C, 2-2A, 2-2B, 2-2C, 2-3A, 2-3B, and 2-3C. Data are presented on a quarterly basis as required by Regulatory Guide 1.21 Rev. 1.To complete table 2-1A, and 2-1 B, the total release for each of the four categories (fission and activation gases, iodines, particulates, and tritium) was divided by the number of seconds in the quarter to obtain a release rate in pLCi/second for each category. | |||
However, the percent of the ODCM limits are not applicable because VEGP has no curie limits for gaseous releases. | |||
Applicable limits are expressed in terms of dose. Noble gases are limited as specified in ODCM 3.1.2. The other three categories (tritium, radioiodines, and particulates) are limited as a group as specified in ODCM 3.1.2.Dose rates due to noble gas releases and due to radioiodines, tritium, and particulate releases were calculated as part of the pre-release and post-release permits. No limits were exceeded for this reporting period.Gross alpha radioactivity is reported in Table 2-1A, and 2-1B as curies released in each quarter.Limits for cumulative beta and gamma air doses due to noble gases are specified in ODCM 3.1.3. Cumulative air doses are presented in Table 2-4A, and 2-4B along with the percent of the ODCM limits.Page 127 of 503 Limits for cumulative doses to a Member of the Public due to radioiodines, tritium and particulates, are specified in ODCM 3.1.4. Cumulative doses to a Member of the Public are presented in Table 2-5A, and 2-5B along with percent of ODCM limits.2.4 Radiological Impact Due to Gaseous Releases Dose rates due to the release of noble gases were calculated for the site in accordance with ODCM 3.4.1.1. Dose rates due to radioiodines, tritium, and particulates in gaseous releases were calculated in accordance with ODCM 3.4.1.2.Dose rates were calculated as part of pre-release and post release permits. No limits were exceeded for this reporting period.Cumulative air doses due to noble gas releases were calculated for each unit in accordance with ODCM 3.4.2. These results are presented in Tables 2-4A and 2-4B.Cumulative doses to a Member of the Public were calculated for each unit in accordance with ODCM 3.4.3. These results are presented in Tables 2-5A and 2-58.Dose rates and doses were calculated using the methodology presented in the Vogtle Electric Generating Plant Offsite Dose Calculation Manual.2.5 Gaseous Effluents | |||
-Batch Releases Other data pertinent to batch releases of radioactive gaseous effluent from Unit 1 and Unit 2 are listed in Table 2-7A and 2-7B.2.6 Gaseous Effluents | |||
-Abnormal Releases There were no abnormal releases for 2013.Page 128 of 503 Table 2-1A VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Summation Of All Releases Unit: 1 Startina: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Tvye of Effluent Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter A. Fission And Activation Gases 1. Total Release Curies 4.79E-02 4.75E-01 1.88E+00 9.21E+00 2. Average Release rate for period uCi/sec 6.07E-03 6.03E-02 2.38E-01 1.17E+00 3. Percent of Applicable Limit % * * * *B. Radioiodines | |||
: 1. Total Iodine-131 Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2. Average Release rate for period uCi/sec O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 3. Percent of Applicable Limit %* * * *C. Particulates | |||
: 1. Particulates ( Half-Lives | |||
> 8 Days) Curies 1.99E-08 2.38E-08 O.OOE+00 9.14E-07 2. Average Release rate for period uCi/sec 2.53E-09 3.02E-09 O.OOE+00 1.159E-07 3. Percent of Applicable Umit % * * * *D. Tritium 1. Total Release Curies 5.89E+00 8.54E+00 1.21E+01 1.30E+01 2. Average Release rate for period uCi/sec 7.47E-01 1.08E+00 1.53E+00 1.65E+00 3. Percent of Applicable Limit %* * * *E. Gross Alpha 1. Total Release Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2. Average Release rate for period uCi/sec O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00* Applicable limits are expressed in terms of dose. See Tables 2-4A, 2-4B, 2-5A, 2-5B of this report.If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. | |||
Page 129 of 503 Table 2-1B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Summation Of All Releases Unit: 2 Starting: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Type of Effluent Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter A. Fission And Activation Gases 1. Total Release Curies 5.13E+00 1.31E+00 4.91E-02 6.26E-02 2. Average Release rate for period uCi/sec 6.51E-01 1.66E-01 6.23E-03 7.94E-03 3. Percent of Applicable Limit % * * * *B. Radioiodines | |||
: 1. Total Iodine-131 Curies O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 2. Average Release rate for period uCi/sec O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 3. Percent of Applicable Umit %* * * *C. Particulates | |||
: 1. Particulates ( Half-Lives | |||
> 8 Days) Curies O.OOE+00 6.52E-08 O.OOE+00 7.80E-08 2. Average Release rate for period uCi/sec O.OOE+00 8.27E-09 O.OOE+00 9.893E-09 3. Percent of Applicable Limit %* * * *D. Tritium 1. Total Release Curies 1.36E+01 2.84E+00 2.16E+00 8.95E-01 2. Average Release rate for period uCi/sec 1.72E+00 3.61E-01 2.74E-01 1.14E-01 3. Percent of Applicable Limit %* * * *E. Gross Alpha 1. Total Release Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2. Average Release rate for period uCi/sec O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00* Applicable limits are expressed in terms of dose. See Tables 2-4A, 2-4B, 2-5A, 2-5B of this report.If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. | |||
Page 130 of 503 Table 2-1C VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Summation Of All Releases Unit: Site Startino: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Type of Effluent Units 1ST Quarter 2ND Quarter 3RD Ouarter 4TH Quarter A. Fission And Activation Gases 1. Total Release Curies 5.18E+00 1.78E+00 1.92E+00 9.27E+00 2. Average Release rate for period uCi/sec 6.57E-01 2.26E-01 2.44E-01 1.18E+00 3. Percent of Applicable Limit % * * * *B. Radioiodines | |||
: 1. Total Iodine-131 Curies O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 2. Average Release rate for period uCi/sec 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 3. Percent of Applicable Limit %* * * *C. Particulates | |||
: 1. Particulates ( Half-Lives | |||
> 8 Days) Curies 1.99E-08 8.89E-08 0.OOE+00 9.92E-07 2. Average Release rate for period uCi/sec 2.53E-09 1.13E-08 O.OOE+00 1.258E-07 3. Percent of Applicable Limit % * * * *D. Tritium 1. Total Release Curies 1.95E+01 1.14E+01 1.43E+01 1.39E+01 2. Average Release rate for period uCi/sec 2.47E+00 1.44E+00 1.81E+00 1.76E+00 3. Percent of Applicable Limit %* * * *E. Gross Alpha 1. Total Release Curies 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 2. Average Release rate for period uCi/sec O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00* Applicable limits are expressed in terms of dose. See Tables 2-4A, 2-4B, 2-5A, 2-5B of this report.Page 131 of 503 If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. | |||
Page 132 of 503 Table 2-2A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Mixed Mode Level Releases Unit: 1 Starting: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Continuous Mode hiU..A- .4A 0 I hn;4©I .CTOrO+n n r")Nf f.n 1D.'0 En =r+0r ATU fnismr.r Fission Gases Xe-135 Total For Period Iodines No Nuclides Found Particulates Be-7 Sr-90 Total For Period Tritium H-3 Gross Alpha G-Alpha Total For Period Curies Curies Curies Curies Curies Curies 0.OOE+00 0.OOE+O0 0.OOE+00 1.99E-08 1.99E-08 5.78E+00 0.0OE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 2.38E-08 2.38E-08 8.46E+00 0.OOEO00 0.OOE+00 1.80E+00 1.8OE+00 0.OOE+0O 0.OOE+00 0.OOE+00 1.20E+01 5. 74E-08 5.74E-08 9.15E+00 9.15E+00 O.OOE+0O 9.14E-07 O.OOE+00 9.14E-07 1.30E+01 O.OOE+00 O.00E+00 Curies Curies Curies Page 133 of 503 If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. | |||
Table 2-2A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Mixed Mode Level Releases Unit: 1 Startina: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Batch Mode MI n ,-I ,n Di lnc0 c I In;,.'I Cy r%. I)Jhlfm rm@m-nr 2aDf rl.min 'r AT- Minrma Fission Gases Ar-41 Kr-85 Xe-133 Total For Period Iodines No Nuclides Found Particulates No Nuclides Found Tritium H-3 Gross Alpha No Nuclides Found Curies Curies Curies Curies Curies 4.79E-02 O.OOE+00 O.OOE+00 4.79E-02 O.OOE+00 0.00E+00 1.14E-01 0.00E+00 Page 134 of 503 4.75E-01 0.OOE+00 0.OOE+00 4.75E-01 0.OOE+00 0.00E+00 7.97E-02 0.OOE+00 4.85E-02 2.32E-02 6.27E-04 7.24E-02 0.OOE+00 0.00E+00 5.47E-02 0.OOE+00 5.80E-02 0.OOE+00 0.OOE+00 5.80E-02 0.OOE+00 0.00E+00 2. 54E-02 0.OOE+00 Curies Curies Curies If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 2-6 for typical minimum detectable concentrations. | |||
Page 135 of 503 Table 2-2B VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Mixed Mode Level Releases Unit: 2 Startina: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Continuous Mode I KnuIM D'aIaa'ce I Inii-c 11 &-r"If o2Dn AYUW .4 2z .gua. vu. be" Mug Lý* Mug ýO ~ ..** 0 Fission Gases No Nuclides Found Iodines No Nuclides Found Particulates Sr-89 Sr-90 Total For Period Tritium H-3 Gross Alpha No Nuclides Found Curies Curies Curies Curies Curies 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 4.09E+00 0.001E+00 0.00E+00 0.OOE+00 5.24E-08 1.28E-08 6.52E-08 2.62E+00 0.OOE+00 0.00 E+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 2.04E+00 0.OOE+00 0.OOE+00 0.OOE+00 7.80E-08 0.OOE+00 7.80E-08 0.OOE+00 0.OOE÷00 Curies Curies If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 2-6 for typical minimum detectable concentrations. | |||
Page 136 of 503 Table 2-2B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Mixed Mode Level Releases Unit: 2 Startina: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Batch Mode 1ST Quarter 2ND Quarter 3RD Qua 5.67E-01 5.14E-01 3.OOE-(4.47E+00 7.93E-01 1.91E-(5.39E-02 4.77E-04 5.99E-(5.10E+00 1.31E+00 4.91E-4 O.OOE+O0 O.OOE+O0 O.OOE+i Liquid Releases Fission Gases Ar-41 Xe-133 Xe-135 Total For Period Iodines No Nuclides Found Particulates No Nuclides Found Tritium H-3 Gross Alpha No Nuclides Found Units Curies Curies Curies Curies Curies rter)2 32 D5 02 00 4TH Quarter 2.38E-02 3.83E-02 5.14E-04 6.26E-02 O.OOE+O0 Curies Curies 0.OOE+00 9.43E+00 O.OOE+00 O.OOE+00 2.18E-01 O.OOE+O0 O.00E+00 1.26E-01 O.OOE+OO O.OOE+OO 8.95E-01 O.OOE+00 Curies Page 137 of 503 If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. | |||
Page 138 of 503 Table 2-2C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Mixed Mode Level Releases Unit: Site Startina: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Continuous Mode 1ST Quarter 2ND Quarter 3RD Qua Nuclide Releases Fission Gases Xe-135 Total For Period Iodines No Nuclides Found Particulates Be-7 Sr-89 Sr-90 Total For Period Tritium H-3 Gross Alpha G-Alpha Total For Period Units irter Curies Curies Curies Curies Curies Curies Curies O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+O0 1.99E-08 1.99E-08 9.86E+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 5.24E-08 3. 66E-08 8.89E-08 1.11E+01 O.OOE+00 O.OOE+00 1.80E+00 1.80E+00 0.OOE+00 0.OOE+0O 0.OOE+00 0.OOE+00 0.OOE+00 1.41E+01 5.74E-08 5.74E-08 4TH Quarter 9.15E+00 9.15E+00 0.OOE+00 9.14E-07 7.80E-08 0.OOE+00 9.92E-07 1.30E+01 O.OOE+00 0.O0E+00 Curies Curies Curies If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. | |||
Page 139 of 503 Table 2-2C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Mixed Mode Level Releases Unit: Site Starting: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Batch Mode Iu 1,,- .1 Dn_1 " I ;0-12 lu r% .4-*'II m m ATU m EU LI =LI =00I =0 ~ LIN L3 J.L I LIMUE3 LV.1 I U ju l~I ~ ~ ~ M I mdu E V§ U e U U ý ~Fission Gases Ar-41 Kr-85 Xe-133 Xe-135 Total For Period lodines No Nuclides Found Particulates No Nuclides Found Tritium H-3 Gross Alpha No Nuclides Found Curies Curies Curies Curies Curies Curies 6.15SE-01 0.OOE+0O 4.47E+00 5.39E-02 5.14E+00 0.OOE+00 0.OOE+00 9.54E+00 0.OOE+00 9.89E-01 0.OOE+00 7.93E-01 4. 77E-04 1.78E+00 0.OOE+00 0.OOE+00 2.98E-0 1 0.OOE+O0 7.86E-02 2.32E-02 1.97E-02 5.99E-05 1.22E-01 O.OOE+00 O.OOE+00 1.81E-01 O.OOE+00 8.18E-02 O.OOE+00 3.83E-02 5.14E-04 1.21E-01 O.OOE+00 O.OOE+00 9.20E-01 O.OOE+0O Curies Curies Curies Page 140 of 503 If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. | |||
Page 141 of 503 Table 2-3A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Ground Level Releases Unit: 1 Starting: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Continuous Mode 1ST Ouarter 2ND Ouarter 3RD Oua O.OOE+00 O.OOE+00 O.OOE+(Nuclide Releases Fission Gases No Nuclides Found Iodines No Nuclides Found Particulates No Nuclides Found Tritium No Nuclides Found Units Curies rter O0 4TH Ouarter O.OOE+00 Curies Curies 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 Curies Gross Alpha No Nuclides Found Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels.Page 142 of 503 See Table 2-6 for typical minimum detectable concentrations. | |||
Table 2-3A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Ground Level Releases Unit: 1 Starting: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Batch Mode Nirlida Rp~lpacac== | |||
Iinitc 1 7)Nfl fl..arurlrfIl:uIrfprr 4TM Nfal~urI~Units JQT n"n or 2ND nuarter 3RD Ong or 4TH n"garter Fission Gases No Nuclides Found Iodines No Nuclides Found Particulates No Nuclides Found Tritium No Nuclides Found Curies O.OOE+O0 O.OOE+00 O.OOE+O0 O.OOE+O0 Curies O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+00 Curies O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 Curies O.OOE+0o O.OOE+0O O.OOE+00 O.OOE+O0 Gross Alpha No Nuclides Found Curies O.OOE+0O Page 143 of 503 O.OOE+00 O.OOE+00 O.OOE+00 If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 2-6 for typical minimum detectable concentrations. | |||
Page 144 of 503 Table 2-3B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Ground Level Releases Unit: 2 Startina: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Continuous Mode N.rlide Ilnitc 1 flh,2rter 7 Nf Amumrt~~rAmlra~r'r 4TH fliirt~r Nuclide Releases Units IST nun -or 2ND inuarter 3RD nua er 4TH nuarter Fission Gases No Nuclides Found lodines No Nuclides Found Particulates No Nuclides Found Tritium No Nuclides Found Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Gross Alpha No Nuclides Found Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 2-6 for typical minimum detectable concentrations. | |||
Page 145 of 503 Table 2-3B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Ground Level Releases Unit: 2 Startina: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Batch Mode Ni ir"lign cajc Ilnifc 1 lNfl flnimrh~rfl.iart~r 4TH Anartpr Units IST nua er 2ND nuarter 3RD Ouarter Fission Gases Ar-41 Xe-133 Xe-135 Total For Period lodines No Nuclides Found Particulates No Nuclides Found Tritium H-3 Gross Alpha No Nuclides Found Curies Curies Curies Curies 3.67E-03 3.01E-02 3.72E-04 3.42E-02 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Curies 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Curies Curies O.OOE+00 7.42E-02 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 Curies 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels. See Page 146 of 503 Table 2-6 for typical minimum detectable concentrations. | |||
Page 147 of 503 Table 2-3C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Ground Level Releases Unit: Site Starting: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Continuous Mode Nuclide Releases Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter Fission Gases No Nuclides Found Curies O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+O0 lodines No Nuclides Found Curies O.OOE+O0 O.OOE+O0 O.OOE+0O O.OOE+O0 Particulates No Nuclides Found Curies O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+O0 Tritium No Nuclides Found Curies O.OOE+O0 O.OOE+00 O.OOE+O0 O.OOE+00 Gross Alpha No Nuclides Found Curies O.OOE+00 O.OOE+O0 O.OOE+0O O.OOE+O0 If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 2-6 for typical minimum detectable concentrations. | |||
Page 148 of 503 Table 2-3C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Ground Level Releases Unit:Site Startino: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Batch Mode Nirlida gplpacpc ilnitc 1 ~ Am ,rI~rlrO.artor~Rfl AmiarI~r 4TH l.arn~rh Units 1ST nua er 2ND nua er 3RD nuar+er 4TH nuarter Fission Gases Ar-41 Xe-133 Xe-135 Total For Period Iodines No Nuclides Found Particulates No Nuclides Found Tritium H-3 Gross Alpha No Nuclides Found Curies Curies Curies Curies 3.67E-03 3.01E-02 3.72E-04 3.42E-02 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Curies Curies 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Curies 7.42E-02 0.OOE+00 0.OOE+00 0.OOE+00 Curies 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 2-6 for typical minimum detectable concentrations. | |||
Page 149 of 503 Table 2-4A VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Ground Level Releases Unit: 1 Startina: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Type of Radiation ODCM Lint Units Gamma Air 5.OOE+00 mRad Beta Air 1.OOE+01 mRad 1ST Qtr 6.52E-06 2.30E-06%/o ODCM 1.30E-04 2.30E-05 2ND Qtr 6.47E-05 2.28E-05%/a ODCM 1.29E-03 2.28E-04 3RD Qtr 5.73E-05 6.80E-05 0/b ODCM 1. 15E-03 6.80E-04 4TH Qtr 2.65E-04 3.33E-04%/o ODCM 5.31E-03 3.33E-03 Cumulative Doses Per Year Type of Radiation ODCM Lint Gamma Air 1.00E+01 Beta Air 2.OOE+01 Units mRad mRad Year to End Date 3.94E-04 4.26E-04%/c ODCM 3.94E-03 2.13E-03 Receptor Site Boundary / Child Site Boundary / Child Limit Air Dose Gamma Annual 1.21 Air Dose Beta Annual 1.21 Page 150 of 503 Table 2-46 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Ground Level Releases Unit: 2 Starting: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Type of Radiation ODCM Lint Units Gamma Air 5.OOE+00 mRad Beta Air 1.00E+01 mRad 1ST Qtr 1.06E-04 1.02E-04%/o ODCM 2.11E-03 1.02E-03 2ND Qtr 7.41E-05 3.69E-05%/o ODCM 1.48E-03 3.69E-04 3RD Qtr 4.19E-06 1.74E-06 0/0 ODCM 8.38E-05 1.74E-05 4TH Qtr 3.45E-06 1.75E-06%/o ODCM 6.90E-05 1.75E-05 Cumulative Doses Per Year Type of Radiation ODCM Lrnt Gamma Air 1.00E+01 Beta Air 2.OOE+01 Units mRad mRad Year to End Date 1.87E-04 1.42E-04%/o ODCM 1.87E-03 7. 1OE-04 Receptor Site Boundary / Child Site Boundary / Child Limit Air Dose Gamma Annual 1.21 Air Dose Beta Annual 1.21 Page 151 of 503 Table 2-4C VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Ground Level Releases Unit: Site Starting: | |||
1-lan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Type of Radiation ODCM Lmt Units 1ST Qtr %/a ODCM 2ND Qtr %/a ODCM 3RD Qtr %/o ODCM 4TH Qtr %/a ODCM Gamma Air Beta Air 5.OOE+00 mRad 1.12E-04 2.24E-03 1.39E-04 2.78E-03 6.15E-05 1.23E-03 2.69E-04 5.38E-03 1.00E+01 mRad 1.04E-04 1.04E-03 5.97E-05 5.97E-04 6.97E-05 6.97E-04 3.34E-04 3.34E-03 Cumulative Doses Per Year Type of Radiation ODCM Lmt Units Year to End Date% ODCM Receptor Limit Gamma Air Beta Air 1.OOE+01 mRad 2.OOE+01 mRad 5.81E-04 5.68E-04 5.81E-03 Site Boundary / Child 2.84E-03 Site Boundary / Child Air Dose Gamma Annual 1.21 Air Dose Beta Annual 1.21 Page 152 of 503 Table 2-5A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses To a Member of the Public Due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: 1 Startina: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Uver Lung Thyroid Total Body ODCM Lint 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 Units mRem mRem mRem mRem mRem mRem mRem IST Qtr 7.91E-07 1.27E-04 1.27E-04 1.27E-04 1.27E-04 1.27E-04 1.28E-04 0/0 ODCM 1.05E-05 1.70E-03 1.70E-03 1.70E-03 1. 70E-03 1.70E-03 1.70E-03 2ND Qtr 9.43E-07 1.85E-04 1.85E-04 1.85E-04 1.85E-04 1.85E-04 1.85E-04 0/o ODCM 1.26E-05 2.46E-03 2.46E-03 2.46E-03 2.46E-03 2.46E-03 2.46E-03 3 RD Qtr 0.00E+00 2.61E-04 2.61E-04 2.61E-04 2.61E-04 2.61E-04 2.61E-04 0/o ODCM 0.OOE+00 3.49E-03 3.49E-03 3.49E-03 3.49E-03 3.49E-03 3.49E-03 4TH Qtr 0.OOE+00 2.81E-04 2.81E-04 2.81E-04 2.81E-04 2.81E-04 2.81E-04%/o ODCM 0.OOE+00 3.75E-03 3.75E-03 3.75E-03 3.75E-03 3.75E-03 3.75E-03 Cumulative Doses per Year Organ Bone GI-Lli Kidney Liver Lung Thyroid Total Body ODCM Lmt 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 Units mRem mRem mRem mRem mRem mRem mRem Year to Ending Date/o ODCM Receptor Limit 1.734E-06 8.545E-04 8.545E-04 8.545E-04 8.545E-04 8.545E-04 8.549E-04 1. 156E-5 5.697E-03 5.697E-03 5.697E-03 5.697E-03 5.697E-03 5.700E-03 Maximum Individual Maximum Individua Maximum Individua Maximum Individua Maximum Individua Maximum Individua Maximum Individual | |||
/ Child/ Child/ Child/ Child/ Child/ Child/ Child Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual 1.21 1.21 1.21 1.21 1.21 1.21 1.21 Page 153 of 503 Table 2-5B VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses To a Member of the Public Due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: 2 Startina: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Uver Lung Thyroid Total Body ODCM Lmt 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 Units mRem mRem mRem mRem mRem mRem mRem 1ST Qtr O.OOE+O0 3.OOE-04 3.OOE-04 3.OOE-04 3.OOE-04 3.OOE-04 3.OOE-04%/o ODCM O.OOE+O0 4.OOE-03 4.OOE-03 4.OOE-03 4.OOE-03 4.OOE-03 4.OOE-03 2ND Qtr 5.69E-07 6.15E-05 6.15E-05 6.15E-05 6.15E-05 6.15E-05 6.16E-05 0/o ODCM 7.59E-06 8.20E-04 8.20E-04 8.20E-04 8.20E-04 8.20E-04 8.21E-04 3RD Qtr O.OOE+00 4.67E-05 4.67E-05 4.67E-05 4.67E-05 4.67E-05 4.67E-05 0/o ODCM 0.OOE+00 6.23E-04 6.23E-04 6.23E-04 6.23E-04 6.23E-04 6.23E-04 4TH Qtr 9.17E-08 1.94E-05 1.93E-05 1.93E-05 1.93E-05 1.93E-05 1.94E-05 0/b ODCM 1.22E-06 2.58E-04 2.58E-04 2.58E-04 2.58E-04 2.58E-04 2.58E-04 Cumulative Doses per Year Organ Bone GI-Lli Kidney Uver Lung Thyroid Total Body ODCM Lmt 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 Units mRem mRem mRem mRem mRem mRem mRem Year to Ending Date 0/a ODCM Receptor Limit 6.606E-07 4.276E-04 4.276E-04 4.276E-04 4.276E-04 4.276E-04 4.277E-04 4.404E-6 2.850E-03 2.850E-03 2.850E-03 2.850E-03 2.850E-03 2.851E-03 Maximum Individual Maximum Individua Maximum Individua Maximum Individua Maximum Individua Maximum Individua Maximum Individual | |||
/ Child/ Child/ Child/ Child/ Child/ Child/ Child Iodine/Part Dose Annual 1.21 Iodine/Part Dose Annual 1.21 Iodine/Part Dose Annual 1.21 Iodine/Part Dose Annual 1.21 Iodine/Part Dose Annual 1.21 Iodine/Part Dose Annual 1.21 Iodine/Part Dose Annual 1.21 Page 154 of 503 Table 2-5C VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses To a Member of the Public Due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: Site Starting: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Uver Lung Thyroid Total Body ODCM Lint 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 Units mRem mRem mRem mRem mRem mRem mRem 1ST Qtr 7.91E-07 4.27E-04 4.27E-04 4.27E-04 4.27E-04 4.27E-04 4.28E-04%/o ODCM 1.05E-05 5.70E-03 5.70E-03 5.70E-03 5.70E-03 5.70E-03 5.70E-03 2ND Qtr 1.51E-06 2.46E-04 2.46E-04 2.46E-04 2.46E-04 2.46E-04 2.46E-04% ODCM 2.02E-05 3.28E-03 3.28E-03 3.28E-03 3.28E-03 3.28E-03 3.28E-03 3RD Qtr O.OOE+00 3.08E-04 3.08E-04 3.08E-04 3.08E-04 3.08E-04 3.08E-04%/ ODCM O.OOE+OO 4.11E-03 4.11E-03 4.11E-03 4.11E-03 4.11E-03 4.11E-03 4TH Qtr 9.17E-08 3.OOE-04 3.OOE-04 3.OOE-04 3.OOE-04 3.OOE-04 3.OOE-04% ODCM 1.22E-06 4.01E-03 4.01E-03 4.01E-03 4.01E-03 4.01E-03 4.01E-03 Cumulative Doses per Year Organ Bone GI-Lli Kidney Uver Lung Thyroid Total Body ODCM Lmt 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 Units mRem mRem mRem mRem mRem mRem mRem Year to Ending Date% ODCM Receptor 2.395E-06 1.282E-03 1.282E-03 1.282E-03 1.282E-03 1.282E-03 1.283E-03 1.597E-05 8.547E-03 8.547E-03 8.547E-03 8.547E-03 8.547E-03 8.551E-03 Maximum Individual Maximum Individual Maximum Individual Maximum Individual Maximum Individual Maximum Individual Maximum Individual | |||
/ Child I Child/ Child I Child/ Child/ Child/ Child Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Limit 1.21 1.21 1.21 1.21 1.21 1.21 1.21 Page 155 of 503 Page 156 of 503 Table 2-6 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 MINIMUM DETECTABLE CONCENTRATIONS GASEOUS SAMPLE ANALYSES Starting: | |||
1-Jan-2013 Ending: 31-Dec-2013 RADIONUCLIDE MDC UNITS Kr-87 1.82E-08 iiCi/ml Kr-88 2.53E-08 p.Ci/ml Xe-133 2.05E-08 pCi/ml Xe-133m 8.63E-08 p.Ci/ml Xe-135 7.12E-08 P.Ci/ml Xe-138 1.05E-07 tCi/ml 1-131 7.93E-15* | |||
pCi/ml Mn-54 3.94E-14* | |||
!pCi/ml Fe-59 2.45E-14* | |||
ilCi/ml Co-58 1.39E-14* | |||
ptCi/ml Co-60 1.75E-14* | |||
ipCi/ml Zn-65 2.82E-14* | |||
ptCi/ml Mo-99 9.57E-14* | |||
pCi/ml Cs-134 1.12E-14* | |||
pCi/ml Cs-137 8.71E-15* | |||
ptCi/ml Ce-141 8.62E-15* | |||
ptCi/ml Ce-144 2.77E-14* | |||
pCi/ml Sr-89 1.OOE-13 pCi/ml Sr-90 1.OOE-13 pLCi/ml H-3 9.OOE-08 pCi/ml Gross Alpha 1.00E-13 p.Ci/ml* Based on an estimated sample volume of 5.7E+08 mis for particulate filters and charcoal cartridges. | |||
Page 157 of 503 Table 2-7A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Batch Release Summary Unit: 1 Startina: | |||
1-Jan- 2013 Endina: 31-Dec-2013 f-, &-^.- DM-ý-e Ilni4.1. Number of batch releases 2. Total time period for batch releases 3. Maximum time period for a batch release 4. Average time period for a batch release 5. Minimum time period for a batch release ( Minutes)(Minutes)(Minutes)(Minutes)1ST Ouarter 28 1.55E+03 1.OOE+02 5.52E+01 7.OOE+00 2ND Quarter 3RD Quarter 4TH Ouarter 42 32 32 3.38E+03 3.37E+03 2.05E+03 4.80E+02 1.03E+03 1.50E+02 8.06E+01 1.05E+02 6.41E+01 3.OOE+O0 2.10E+01 2.60E+01 Year Totals Year Totals 134 1.04E+04 1.03E+03 7.73E+01 3.OOE+O0 Page 158 of 503 Table 2-7B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Batch Release Summary Unit: 2 Startina: | |||
1-Jan- 2013 Endina: 31-Dec-2013 r .eaue a ea I Inilc ICT ga'rN, t r 2Nfl flf.2r4~nr 2Dfl flm.~rt~r | |||
~TI.I fluI2rta~r | |||
,3mn n"nr+ar 'ADD n"n or AT&i nu:%r+ar b!1. Number of batch releases 2. Total time period for batch releases 3. Maximum time period for a batch release 4. Average time period for a batch release 5. Minimum time period for a batch release (Minutes)(Minutes)(Minutes)(Minutes)39 2.70E+04 8.OOE+03 6.93E+02 6.OOE+O0 12 8.42E+03 7.99E+03 7.02E+02 1.00E+01 11 7.21E+02 2.93E+02 6.55E+01 2.30E+01 12 5.98E+02 1.39E+02 4.98E+01 2.40E+01 Year Totals 74 3.67E+04 8.OOE+03 4.97E+02 6.OOE+O0 Page 159 of 503 Table 2-7C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Batch Release Summary Unit: Site Startina: | |||
1-lan- 2013 Ending: 31-Dec-2013 gaseous Releases Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter Year Totals 1. Number of batch releases 67 54 43 44 208 2. Total time period for batch releases (Minutes) 2.86E+04 1.18E+04 4.09E+03 2.65E+03 4.71E+04 3. Maximum time period for a batch release (Minutes) 8.OOE+03 7.99E+03 1.03E+03 1.50E+02 8.OOE+03 4. Average time period for a batch release (Minutes) 4.26E+02 2.19E+02 9.52E+01 6.02E+01 2.26E+02 5. Minimum time period for a batch release (Minutes) 6.OOE+0O 3.OOE+0O 2.10E+01 2.40E+01 3.OOE+0O Page 160 of 503 Table 2-8A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Abnormal Release Summary Unit: 1 Startina: | |||
1-Jan- 2013 Ending: 31-Dec-2013 Gaseous Releases Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter Year Totals 1. Number of Releases 0 0 0 0 0 2. Total Time For All Releases (Minutes) | |||
O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 3. Maximum Time For A Release (Minutes) | |||
O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 4. Average Time For A Release (Minutes) | |||
O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 5. Minimum Time For A Release (Minutes) | |||
O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 6. Total activity for all releases (Curies ) O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Page 161 of 503 Table 2-8B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Abnormal Release Summary Unit: 2 Startina: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Gaseous Releases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Year Totals 1. Number of Releases 0 0 0 0 0 2. Total Time For All Releases (Minutes) | |||
O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 3. Maximum Time For A Release (Minutes) | |||
O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 4. Average Time For A Release (Minutes) | |||
O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 5. Minimum Time For A Release (Minutes) | |||
O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 6. Total activity for all releases (Curies ) O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Page 162 of 503 Table 2-8C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents | |||
-Abnormal Release Summary Unit: Site Starting: | |||
1-Jan- 2013 Endina: 31-Dec-2013 Gaseous Releases Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter Year Totals 1. Number of Releases 0 0 0 0 0 2. Total Time For All Releases (Minutes) 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 3. Maximum Time For A Release (Minutes) 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 4. Average Time For A Release (Minutes) 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 5. Minimum Time For A Release (Minutes) 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 6. Total activity for all releases (Curies ) 0.00E+00 0.OOE+00 O.OOE+00 0.OOE+00 0.00E+00 Page 163 of 503 | |||
===3.0 Solid=== | |||
Waste 3.1 Regulatory Requirements The ODCM requirements presented in this section are stated in part for Unit 1 and Unit 2.3.1.1 Solid Radioactive Waste System 10.2.1 Process Control Program (PCP)Radioactive wastes shall be solidified or dewatered in accordance with the PCP to meet shipping and transportation requirements during transit and disposal site requirements when received at the disposal site.3.1.2 Reporting Requirements 12.1 PCP states in part: The Radioactive Effluent Release Report, submitted in accordance with Technical Specification 5.6.3, shall include a summary of the quantities of solid radwaste released from the units, as outlined in Regulatory Guide 1.21 Rev 2.3.2 Solid Waste Data Regulatory Guide 1.21 Rev 2, Table 3 is found in this report as Table 3-1. GEL Laboratories performs hard-to-detect analysis for solid waste. Final calculations for nuclides include sample analysis performed on resin from High Integrity Containers. | |||
For Gaseous and Liquid composites, the Georgia Power Environmental Laboratory performs hard-to-detect analysis.Page 164 of 503 Table 3-1 Vogtie Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units 1 and 2 Page 1 of 9 JANUARY 1, 2013 THROUGH JUNE 30, 2013 Page 165 of 503 Regulatory Guide 1.21, Effluent and Waste Disposal Semi-Annual Report ot Solid Waste and Irradiated Fuel Shipments | |||
¢/aT,, PERIOD COVERED: FROM: 1/1/2.013 TO: 6="O/2013 FOR UNIT I & 2 A. SOIUD WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not iradbaled tuel)I.. Type of waste UNIT 6 month Est, Total......_peiod ERROR %Dry oornpTes5fe waste, contaninated equip. fro 1ý83E2 25 etc. ,V U Ci=-0s A?) Cl 5.27E-1 25 Steam Generator Blow Down Resin (Seconcdary Side Resin) _e 6,43EI 25 2. Es-timat~e of maiom nue~ft compxosion (by peof waste)ISOTOPE PERCENT CURIES[ycaipressible waste, contaminated equip. e~c WNA N/A Co,58 46.933 2.47e-1 CO-60 16.526 8.7Ne-2 Cr-51 111,053 5.82e-2 Fe--55 8.,50 4.48e-2 Nb-95 6.288 2.78e-2 NI-63 3.843 2.02e-2 Mn-54 2.963 1.55e-2 Zr-95 2.586 1.38e-2 Fe-59 0,538 2.82a.3 Zn.65 0.367 1.93e,3 Sb-1 25 0.381 1.900-3 Cs-137 0.260 1.37e-3 Sn-1 13, H-3, U0-57, Cs-134, C-14, St-90 I.% 4,1 le-3 Stoam Generator Slow Down Resin (Secondaiy Side Resin) .......Co-58 39.107 9.1 te-3 CO-60 23,996 5,560-311.553 2.6N-3 M-__..63 7-219 1.63e-3 Ct-5I 6.460 1,.27e..3 Mn-64 3.346 7.790.4 Nb-95 3.106 7.23e-42.076 4.83e4 H-3 1.699 3.96-4 Sb- 125 0.544 127e-4 Cs- 137 ,0r.4 1,,14ea4 Zn-65 0.394 9.17a-5 Fe,59 0.363 6.46e-.Co-57 0.226 5.21e-5 0S- ,1 ,- 5.230e-Cs-1134. C-14, Sr-90, Co-1 44, Nb-94, Sol.124 >%6-949-2 Table 3-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units 1 and 2 JANUARY 1, 2013 THROUGH JUNE 30, 2013 Page 166 of 503 Page 2 of 9 NRC Regulatory Guide 1.21 Reports Page 1 ReportDate: | |||
30812014 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream Ouring Period From 01101)2013 to 06&3V2013 Percent Cutaff 0 Waste Siream: Resins, Fifters, and Evap Bottomns Waste Volume Curies % Error Class Ft^3 MA3 Shipped (Ci)A 0=00E+00 000E+00 0,00E+00 +t/ 25%B 000E+0O 0.OOE÷00 0.00E+00 ÷1/ 25%C 0.00E+00 0.00E+00 0.OQE+00 +/1 25%All 0.00E+00 O.OOE+00 0.00E+00 +1- 25%Waste Stream SS DAW Dry Active Waste Dry Active Waste*waste Vof ure Curies %Error Class3Ft' 3 Shipped i CI)C 0.0OE+00 0.OOE+00 0,OOE.O0 +1-25%All ;.47E+03 1.83E+02 5.27E-01 +1 *25%Waste Stream Irradiated Components w~ipVolume Curies ý4 Error Class FtA3 M-%3 Shipped iCl)A O0O0E+00 0.OOE+00 0.00E+0O +/-25%B 0.C0E+00O .OOE+O0 0.OOE+0O +1-25%C 0,00E+00 000OE+00 i 0.0OE+00 +1-25%All I0.OOE+00 0,O0E+00 0.OOE+00 +/-26%Table 3-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units I and 2 Page 167 of 503 Page 3 of 9 JANUARY 1, 2013 THROUGH JUNE 30, 2013 NRC Regulatory Guide 1.21 Reports P;UA 2 Report Date" 3W/12014 Solid Waste Shipped Qftsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Perfiod From 0110112013 to 06130/2013 Percent Cutoff 0 Waste Stream Other Waste SGDU C,.,51N (1olt) SGBO Resin (Clips)Waste Volume Curies % Error class FtA3 M,3 Shipped (Ci)A 2,27E+a3 6,43E+O1 2,33E-02 41-25%S 0,00E+00 0.00E+00 0.00E+00 +1-25%C 0,OOE+00 0,00E+O0 0.00E+00 +1-25%All 2,27E+03 6-43E+01 2.33E-02 +1-25%Waste Stream : Sum or A41 4 Categorfes SGBD RESIN (Bolt) SS DAW Dry Active Waste* SGBD Resin (Clips)Waste Volume Curies % Error Class j FtA3 MA3 Shipped (CI)A [8774E+03 2.47E+02 5.50E-01 +/-25%B 0.00E+00 0.00E+-00 0,OOE+00 +/-25%C .OOE+00 0.OOE+00 0.00E+00 +1-25%AJI 8j 74 E+03 2ý47E.02 5,50E.01 +1.25%-Combined Waste Type Shipment, Major Volume Waste Type Shown Table 3-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL REPORT -2013 Page 168 of 503 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units I and 2 JANUARY 1, 2013 THROUGH JUNE 30, 2013 NRC Regulatory Guide 1.21 Reports Page 4 of 9 Page 1 Report Date: 3/6I2014..... ... ..... ... ... ..... ..... .... ..............,... ... .... .. ..... ......Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/0112013 to 06/3012013 "7L .".7 "" ' .... ..... .... " "........ | |||
". ..... .... .." ........ .... ... ......... ..... ... ..: .. ; .."'.....:., ', Number of Shipments Mode of Transportation Destinatlei' 5 Hittman Transport ENERGY SOLUTIONS 4 Hiftman Transport GTSD GALLAHER TABLE 3-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT -2013 Page 169 of 503 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units 1 and 2 JULY 1, 2013 THROUGH DECEMBER 31, 2013 Page 5 of 9 Regulatory Guide 1.21: Effluent and Waste Disposal Semi-Annual Report of Solid Waste and Irradiated Fuel Shipments PERIOD COVERED: FROM: 72013 ... TO: 12/31L21 3 FOR UNIT: !A.2 _A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)Type of waste UNIT 6 month Esi, Total........... | |||
period ERROR %Rosins and Filters (NRC Waste Class A) m3 102 EI 25 Ci 2.,3Ei 25 Dry compressible waste. corntaminated equip. T -5.01 El 25 etc., (NRC Waste Class A) CI 2.64E-2 25 Steam Generator Blow Down Rosin (Secondary Side tm 3.70E1 25 (NRC Waste Class A Ci 5.,58E,3 25 2. Eslimate of major nuclide composition (by tyr* of waste)ISOTOPE PERCENT CURIES Resins and Filters (NRC Waste Class A)Ni-63 42.644 1.02E1 Com60 28,314 5.75 Fe-55 15.718 3.75 Cs-137 5.080 1,21 Co-68 3.604 859E.1 SbI25 1.335 3.1BE-1 , Cs-134 ................ | |||
0.849 2.02E-1 C-14 , 0.815 1.94E-1 Mn-54 0.749 1-78E-l Nb-95 0.199 4.73E-2 Ni-59 0,194 4.62E-2 Zr-95 0.130 3.11 E-2 7n-65 0,106 2.53E-2 H-3,Co-57,Sr-9.0,Cr-51 ,Tc-99,Fe-.9Sn.1-13,Nb-94.Ce-144,Pu-241 | |||
>0.1% 6.25E-2 Dry compressible waste, contaminated equip. etc NA .A (NRC Waste Class A)_________ | |||
________Co058 46.319 1.22E-2 Co-60 1-199 4.80E-3 Fe-5, 9,334 2,46E-3 Cr-5i 9-137 2.41E-3 Nb-95 4.647 1.23E-3 NI-63 4.249 2.02E-2 Mn,54 3.183 1.12E-3_____________________________ | |||
2.522 6.65E-4 Fe-59 0.495 1.31E-4 Sb'125 0.396 1.04E-40.3w 1.04E-4 Cs-137 0.287 7.57E-5 Sn-I 13, K-.3, Co-57, Cs-134, C-14, S-90 .. I1% 2.12E-4 TABLE 3-1 Page 170 of 503 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units I and 2 Page 6 of9 JULY 1, 2013 THROUGH DECEMBER 31, 2013 Steam Oenerator Blow Down Resin (Secondary Side Resin)ANRC Waste Class A) ........Co-58 36.717 2,05E-3 Co-60 28.398 1,5aE.3 Fe-55 14.106 7.78E-4 Ni-63 6.85. " 3-E-4 Mn-54 4.234 2.36E-4 Cr-51 2,871 160,E-,4 Nb-95 1.990 iE11-4 Zr-95 T.871 1.04E-4 Sb-I25 0.599 3.34E-5 Zn-66 0,499 2,78E-5 Cs-137 0.461 2.57E-5 H--3 0.359 2.OOE-50.275 1.53E-5 Fe-59 0274 1 ,53E-5 Sn-i 13 0.244 1.38E-6 Cs-134, C-14,.St-.90 .A. .1% 1.3GE-5 3. Solid Waste, Visposiflon NuMkhe o ý pmnt 3 Re,-*n tidqqouTr!ý ordatiw Transler Truck with Cask DotnationSolutions Barmvell Processing Facility 16043 Dunbarton Blvd Barnwall, SC 2 Filler 1 DAW Transfer Ttuck with Cask Exclusive use transfaT truck~Energy Solutions 1560 Bear Creek Rd Oak Ridge, TN Energy Soluions 1560 Bear Creek Rd?Oak Ridge, TN Energy Soluilons ,628 Gallahei Rd EKingston. | |||
TN 2 Otier (SeM Resin)transfer Truck 13. IRRADIATED FUEL SHIPMENTS (Disp~osition) | |||
NUmbot of ShiuMents Mgde gf TrMnsportation None NIA ,Nglirjation NIA TABLE 3-1 Page 6 of 503 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units 1 and 2 Page 172 of9 JULY 1, 2013 THROUGH DECEMBER 31, 2013 Page 172 of 5003 NRC Regulatory Guide 1.21 Reports Noge Report Date: 3*12014 Solid Waste Shipped Offsite for Disposal and Estimates of Ma~or Nuclides by Waste Class and Stream During Period From 0710112013 to 1213012013 Percent Cutoff: 0 Waste Stream, Resins, Filters, and Evap Bottoms HIC 11743-01 SFP FILTERS 07-08 RPF Resin TUFS Membranes 3698-13 Waste Volume Cures % Error Class FtA3 M^3 Shipped (Cl)A 316iE+02 1.02E+01 2.38E*01 +f- 25%B 0.00E+00 0,00E+O0 0.OOE+00 +1- 25%C 0O.0E+00 0,00E+00 0.OOE+00 +1- 25%All 3.61E+02 1.02E+01 2.38E+01 +/-25%Waste Stream : Dry Active Waste Dry Actve Wastek Waste Volume CuriesI %Error Cl~ass FtA3 M113 Shipped j (CIq A 1,77E+03 6-01 E+01 2,64&~02 -5 a 0.0QE+00 O.0OE+00 0.0OE+00 f 1-25%C 0.O0Q4-00 0O0OE+00 0.00E+00 j +1-25%All 1.77E+0~3 5.01 E+01 2.641202 +1-25%Waste Stream , Irradiated Components Waste Volume Curies % Error Class FtA3 MA3 Shipped (Ci)A 0=00E+00 0.00E.00 0.00E+00 +/-25%B 0-OOE+00 O.OOE+00 0.00E+00 +1-25%C 0.002E+00 0.OOE+00 0.00E+O0 +-25%All 0.0oE+00 o 0,0E1+O0 .OOE+00 +/-25%TABLE 3-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units 1 and 2 Page 8 of 9 Page 173 of 503 JULY 1, 2013 THROUGH DECEMBER 31, 2013 NRC Regulatory Guide 1.21 Reports TPege 2Date: W362914 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Peiod From 07t01/2013 to 12130/2013 Percent Cutoff' 0 Waste Stream Other Waste SGBD RESIN (Bolt) SGBD Resin (Clips)Waste Volume Curies % Error Class FtA3 MA3 Shipped ICi)A 1,31E+03 3,70E+01 5.58E-03 +1-25%B O.00E+00 O.00E+00 O.OE+0-25% | |||
C Q,00E+O0 0.OOE+00 O,OOE+00 +/-25%All 1,31E+03 3.70E+01 6.68E-O3 +/-25%Waste Stream : Sum of All 4 Categories SGBD RESIN (Bolt) HIC 11743-OI RPF Resin TUFS Membranes SFP FILTERS 07-08 Dry Active Waste*3698-13 SGBD Resin (Clips)waste Volume Curies % Error Class Ft&3 MA3 Shipped P)i A 144E+03 9.73E+01 2,39E+01 +1-25%B O-0OE+00 04012+00 0.00E+00 +/-25%C 0.00E+O0 O.00E+00 OOOE.+00 +1-25"A Ali 3,44E+.03 9.73E+01 2.39E+0O1 | |||
+1-25%-Combined Waste Type Shipment, Major Volume Waste ae Shown TABLE 3-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Page 174 of 503 Urits I ard 2 AllY 1,2013 THROIiH IJECEI'IJER 31,2013 NRC Regulatory Guide 1.21 Reports Page9 d 9 Page I Report Date: :lill 01 Solid Waste Shipped Offsite for 15sposaland Estimatesof Major Nuclides by Waste Class and Stream Durtng Period From 0710112013 to 1213012013 Number of Shlpmetats | |||
,_of Transportation Destination 3 Hittman Transport O'tQC<Koong Facity.3 HlttmanTransport L T1 10 N" 2 HillmanTransport IGT IGALLAHER 4.0 Doses to Members ofthe Public inside the Site Boundary Page 175 olf503 | |||
===4.1 Regulatory=== | |||
Requirements ODCM 7.2.2.3 states in part: "The report shall also include assessment of the radiation doses from radioactive liquid and gaseous effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY during the report period; this assessment must be performed in accordance with Chapter 6. All assumptions used in making these assessments ( i.e., specific activity, exposure time, and location) shall be included in the report".4.2 Demonstration of Compliance The location of concern within the site boundary is the Visitors Center. The activities at the Visitor Center consist of occasional attendance at meetings and/or short visits for informational purposes.There will be no radiation dose at this location due to radioactive liquid effluents. | |||
Delineated in Table 4-1 for this location are the values of the basic data assumed in the dose assessment due to radioactive gaseous effluents. | |||
Listed in this table are distance and direction from a point midway between the center of Unit 1 and the Unit 2 reactors, the dispersion and deposition factors for any releases from the plant vent (mixed mode) and from the turbine building (ground level), and the estimated maximum occupancy factor for an individual and the assumed age group of this individual. | |||
The source term is listed in Tables 2-2A, and 2-2B for the mixed mode releases. | |||
Similarly, it is listed in tables 2-3A and 2-3B for the ground level releases.The maximum doses in units of mrem to a MEMBER OF THE PUBLIC due to their activities inside the site boundary during the reporting period are presented in Table 4-1.Page 176 of 503 Table 4-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses to a Member of the Public Due to Activities Inside the Site Boundary Unit: Site Starting: | |||
1-Jan-2013 Ending: 31-Dec-2013 Location Name: Distance (kilometers): | |||
Sector: Occupancy Factor: Age Group: Ground Level Release Ground Level Release Mixed Mode Release Mixed Mode Release Visitor's Center Receptor 4.47E-01 SE 4.57E-04 Child Noble Gas Particulate and Radioiodine Noble Gas Particulate and Radioiodine X/Q (sec/m3): | |||
5.93E-06 X/Q (sec/m3): | |||
5.58E-06 X/Q (sec/m3): | |||
7.12E-07 X/Q (sec/m3): | |||
6.74E-07 D/Q (m-2): 2.28E-08 D/Q (m-2): 5.77E-09 Bone Liver Total Body Thyroid Kidney Lung GI-Lli NG Total Body Whole Body Dose Units mRem mRem mRem mRem mRem mRem mRem mRem mRem 1ST Quarter 1.97E-11 2.33E-07 2.33E-07 2.33E-07 2.33E-07 2.33E-07 2.33E-07 7.43E-08 3.07E-07 2ND Quarter 3.65E-11 1.32E-07 1.32E-07 1.32E-07 1.32E-07 1.32E-07 1.32E-07 9.26E-08 2.25E-07 3RD Quarter 0.OOE+00 1.66E-07 1.66E-07 1.66E-07 1.66E-07 1.66E-07 1.66E-07 4.09E-08 2.07E-07 4TH Quarter 4.57E-13 1.62E-07 1.62E-07 1.62E-07 1.62E-07 1.62E-07 1.62E-07 1.78E-07 3.40E-07 Year 5.66E-11 6.92E-07 6.92E-07 6.92E-07 6.92E-07 6.92E-07 6.92E-07 3.86E-07 1.08E-06 Page 177 of 503 Table 4-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses to a Member of the Public Due to Activities Inside the Site Boundary Unit: Site Starting: | |||
1-Jan-2013 Ending: 31-Dec-2013 Location Name: Distance (kilometers): | |||
Sector: Occupancy Factor: Age Group: Ground Level Release Ground Level Release Ground Level Release Mixed Mode Release Mixed Mode Release Units 3&4 Construction 4.83E-01 SW 2.37E-01 Adult Noble Gas Particulate and Radioiodine Particulate and Radioiodine Noble Gas Particulate and Radioiodine X/Q (sec/m3): | |||
1.81E-05 X/Q (sec/m3): | |||
6.93E-06 X/Q (sec/m3): | |||
6.96E-06 X/Q (sec/m3): | |||
9.75E-07 X/Q (sec/m3): | |||
9.17E-07 D/Q (m-2): 2.88E-08 D/Q (m-2): 2.88E-08 D/Q (m-2): 7.14E-09 Bone Uver Total Body Thyroid Kidney Lung GI-Lli NG Total Body Whole Body Dose Units mRem mRem mRem mRem mRem mRem mRem mRem mRem 1ST Quarter 1.37E-08 1.93E-04 1.93E-04 1.93E-04 1.93E-04 1.93E-04 1.93E-04 5.60E-05 2.49E-04 2ND Quarter 2.52E-08 1.06E-04 1.06E-04 1.06E-04 1.06E-04 1.06E-04 1.06E-04 6.59E-05 1.72E-04 3RD Quarter O.OOE+00 1.32E-04 1.32E-04 1.32E-04 1.32E-04 1.32E-04 1.32E-04 2.91E-05 1.62E-04 4TH Quarter 1.64E-10 1.29E-04 1.29E-04 1.29E-04 1.29E-04 1.29E-04 1.29E-04 1.27E-04 2.56E-04 Year 3.91E-08 5.61E-04 5.61E-04 5.61E-04 5.61E-04 5.61E-04 5.61E-04 2.78E-04 8.39E-04 Page 178 of 503 Page 179 of 503 | |||
===5.0 Total=== | |||
Dose from Uranium Fuel Cycle (40CFRI90) | |||
===5.1 Regulatory=== | |||
Requirements ODCM 5.1 states in part that the annual (calendar year) dose or dose commitment to any MEMBER OF THE PUBLIC due to releases of radioactivity and to radiation from uranium fuel cycle sources shall be limited to less than or equal to 25 mrems to the whole body or to any organ, except the thyroid, which shall be limited to less than or equal to 75 mrems.5.2 Demonstration of Compliance No dose limits stated in ODCM Sections 2.1.3, 3.1.3, and 3.1.4 were exceeded.Therefore, compliance with 40 CFR 190 dose limits was demonstrated in accordance with the requirements of ODCM Section 5.1.3.6.0 Meteorological Data ODCM 7.2.2.2 states in part: The Radioactive Effluent Release Report shall include an annual summary of hourly meteorological data collected over the previous year.This annual summary may be either in the form of an hour-by-hour listing of wind speed, wind direction, atmospheric stability, and precipitation (if measured) on magnetic tape; or in the form of joint frequency distributions of wind speed, wind direction and atmospheric stability. | |||
In lieu of submission with the Radioactive Effluent Release Report, the licensee has the option of retaining this summary of required meteorological data on site in a file that shall be provided to the NRC upon request.7.0 Program Deviations | |||
===7.1 Inoperable=== | |||
Liquid or Gaseous Effluent Monitoring Instrumentation | |||
====7.1.1 Regulatory==== | |||
Requirement ODCM 7.2.2.6 states in part that the report shall include deviations from the liquid and gaseous effluent monitoring instrumentation operability requirements included in Sections 2.1.1 and 3.1.1, respectively. | |||
The report shall include an explanation as to why the inoperability of liquid or gaseous effluent monitoring instrumentation was not corrected within the specified time requirement. | |||
Page 180 of 503 | |||
====7.1.2 Description==== | |||
of Deviations The inoperability of liquid and gaseous effluent monitors not corrected within the specified time for this reporting period is detailed below.Overall, resources and major projects effected the amount resources that were allocated to repairing the monitors. | |||
During the first half of the year, there were two new radiation monitors installed and a forced maintenance outage. When applicable, compensatory measures were utilized: a. 1RE-12839 This monitor was out of service due to a failed sample pump and a bad heat trace circuit. Work to return to service overlapped with work for 2RE-1 2839.This monitor was returned to service after 36 days.b. 1FT-1085A This transmitter has been delayed with repair because of the unavailability of parts. A new transmitter arrived in September 2013 and was returned to service.c. IFT-12839 Due to a failed calibration, the transmitter was sent offsite for repair.As a result, it was out of service greater than 30 days.d. 1FIS-12862 The flow switch was discovered malfunctioning while performing a work order. Repair will be targeted for this year.e. 2RE-0018 The flow balance valve malfunctioned preventing the throttle of flow for the radiation monitor. The original work instructions were revised to include a total valve rebuild. The time that it took to develop new work instructions and create a clearance for the system extended the out of service time for the monitor. It has been returned to service.f. 2RE-0020B The radiation monitor's skid pump would trip intermittently. | |||
Troubleshooting and replacement of the pump lasted for approximately a week from the start date. As a result, the monitor was returned to service in 33 days.Later in the year, the motor and starter switch was replaced. | |||
This was delayed as a result of the forced maintenance outage. It has been returned to service.g. 2RE-0848 This monitor was declared out of service when the low voltage power supply failed. The CPU board was replaced. | |||
Work orders related to repairing Turbine Drain Header valves extended the out of service time beyond 30 days. The monitor is now in service.Page 181 of 503 | |||
: h. 2FT-12442 At the beginning of the year, this transmitter was declared out of service when it was found out of tolerance for voltage. The transmitter was sent offsite for repair which caused it to be out of service for > 30 days.This flow transmitter was taken out of service after failing a comparison with 2FT-12835 in September 2013. The transmitter is in service.i. AF17620A Dilution flow indication was reading incorrectly. | |||
It is planned to be repaired this year.j. AFQ17620 This totalizer was not incrementing correctly. | |||
Due to parts obsolescence, an equivalency determination had to be performed to make the repair. It has been returned to service.7.2 Tanks Exceeding Curie Content Limits 7.2.1 Regulatory Requirements ODCM 7.2.2.6 states in part that the report shall include a description of the events leading to liquid holdup tanks or gas storage tanks exceeding the limits of Technical Specifications 5.5.12.7.2.2 Description of Deviations Limits for outdoor liquid hold-up tanks used for radioactive liquids were not exceeded during this reporting period.Limits for the gas storage tanks were not exceeded during this reporting period.8.0 Changes to the Vogtle Electric Generating Plant Offsite Dose Calculation Manual (ODCM)8.1 Regulatory Requirements ODCM 7.2.2.5 states in part that changes to the ODCM shall be submitted with the Radioactive Effluent Release Report. These changes may be due to changes in the radiological environmental monitoring program sampling locations as required by ODCM 4.1.1.2.3 or changes to dose calculation locations as required by ODCM 4.1.2.2.2. | |||
Land uses Page 182 of 503 and dose calculation locations within five miles of VEGP must be determined by a land use census as required by ODCM 4.1.2.8.2 Description of Changes Version 29 of the "OFFSITE DOSE CALCULATION MANUAL FOR SOUTHERN NUCLEAR OPERATING COMPANY VOGTLE ELECTRIC GENERATING PLANT" was released in February 2013. The following changes were made: 1) A correction to the Dose Equivalent 1-131 definition for thyroid conversion factors. The ODCM reference stated that the factors were from Table E-7 of NRC Regulatory Guide 1.109, Revision 1, 1977 while Chapter 15 of the VEGP FSAR, Table 15A-5 has a footnote that states these factors are from Table 2.1 of the EPA Federal Guidance Report 11 (EPA-520/1-88-020). | |||
The FSAR definition takes precedence over the ODCM definition. | |||
The software that uses these dose conversion factors already contained the correct conversion factors.2) Equation 2.7 contained a typo with operational signs. Variables fas and Xis should be multiplied instead of summed for the desired results.3) Action Statement 51 was revised to account for the ability to analyze fixed filter paper with gamma spectroscopy after new radiation monitors were installed for the Plant Vent System.9.0 Major Changes to Liquid, Gaseous, or Solid Radwaste Treatment Systems 9.1 Regulatory Requirements ODCM 7.2.2.7 states in part: As required by Sections 2.1.5 and 3.1.6, licensee initiated MAJOR CHANGES TO RADIOACTIVE WASTE TREATMENT SYSTEMS (liquid and gaseous) shall be reported to the Nuclear Regulatory Commission in the Radioactive Effluent Release Report covering the period in which the change was reviewed and accepted for implementation. | |||
Note 1: In lieu of inclusion in the Radioactive Effluents Release Report, this same information may be submitted as part of the annual FSAR update.PCP 12.1 states in part: Page 183 of 503 Licensee major initiated changes to the solid radioactive waste treatment system shall be reported to the Nuclear Regulatory Commission in the Radioactive Effluent Release Report for the period in which the change was implemented. | |||
===9.2 Description=== | |||
of Major Changes Gaseous Radwaste System There were no major changes to the gaseous radwaste systems in the 2013 assessment period.Liquid Radwaste System Major changes to the liquid radwaste facilities are those that contribute to significant changes in release; i.e., either decreases or increases in release volume or activity/dose. | |||
There were no major changes to the liquid radwaste systems occurred during the 2013 assessment period.Solid Radwaste System There were no major changes to the solid radwaste systems in the 2013 assessment period.Page 184 of 503 Appendix A Vogtle Electric Generating Plant CARBON- 14 Carbon-14 (C-14) is a naturally-occurring radionuclide with a 5730 year half life. Nuclear weapons testing in the 1950s and 1960s significantly increased the amount of C-14 in the atmosphere. | |||
Nuclear power plants also produce C-14, but the amount is infinitesimal compared to what has been distributed in the environment due to weapons testing and what is produced by natural cosmic ray interactions. | |||
As nuclear plants have improved gaseous waste processing systems and improved fuel performance, the percentages of "principal radionuclides" in gaseous effluents have changed, and C-14 has become a larger percentage. "Principal radionuclides" are determined based on public dose contribution or the amount of activity discharged compared to other radionuclides of the same effluent type. In Revision 2 (June 2009) of Regulatory Guide 1.21 (RG 1.21), "Measuring, Evaluating, and Reporting Radioactive Material in Liquid and Gaseous Effluents and Solid Waste," the NRC recommended re-evaluating"principal radionuclides" and reporting C-14 as appropriate. | |||
In 2010 Radioactive Effluent Release Reports, virtually all U. S. nuclear power plants started reporting C-14 amounts released and resulting doses to the maximally exposed member of the public.Because C-14 is considered a hard-to-detect radionuclide which must be chemically separated from the effluent stream before it can be measured, RG 1.21 provides the option of calculating the C-14 source term based on power generation. | |||
The Electric Power Research Institute (EPRI) developed an accepted methodology for calculating C-14, and published the results in Technical Report 1021106 (December 2010), "Estimation of Carbon- 14 in Nuclear Power Plant Gaseous Effluents." Evaluation of C- 14 in radioactive liquid effluents is not required because the quantity and dose contribution has been determined to be insignificant. | |||
At Plant Vogtle, the annual quantity of C-14 released in gaseous effluents was estimated to be 12.08 Curies (per unit). Approximately 30% of the C-14 released is in the form of 1 4 C0 2 and is incorporated into plants through photosynthesis. | |||
Ingestion dose results from this pathway. The remaining 70% is estimated to be organic. Both the organic and inorganic forms of C-14 contribute to inhalation dose. A child is the maximally exposed individual, and bone dose is the highest organ dose. Using the dose calculation methodology from the Vogtle ODCM, the resulting bone dose to a child located at the controlling receptor location would be 8.46E-02 mrem in a year which is 0.56% of the regulatory limit of 15 mrem per year (per unit) to any organ due to gaseous effluents. | |||
The resulting total body dose to a child located at the controlling receptor location would be 1.69E-02 mrem in a year which is 0. 11% of the regulatory limit of 15 mrem per year (per unit) total body dose due to gaseous effluents Page 185 of 503 Appendix B Vogtle Electric Generating Plant CORRECTED REPORTS This section contains corrected reports for typos contained in the 2011 and 2012 Annual Radiological Effluent Release Reports: 2011 Report Table 2-5A/U 1 Year to Date -The exponential term for Organ doses were truncated due to formatting. | |||
The values should be E-07/E-04. | |||
Table 2-5C/Site Year to Date -Bone dose is the same as U I 2012 Report Table I-2A/U I (continuous) 3rd quarter -Gross Alpha value should be 0.Table 2-2C/Site (continuous) 4th quarter -The gas total value should be 1.19E+O 1.Table 2-3B/U2 (batch) 3 rd and 4 th quarters -H-3 values should be zero> Table 2-5C/Site Year to Date -All values were from the 2011 ARERR. They were updated to correct to 2012 values.Page 186 of 503 Table 2-5A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2011 Doses To A Member Of The Public Due To Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: 1 Starting: | |||
1-Jan- 2011 Ending: 31-Dec-2011 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Liver Lung Thyroid Total Body ODCM Units 7.50E+00 mRem 7.50E+00 mRem 7.50E+00 mRem 7.50E+00 mRem 7.50E+00 mRem 7.50E+00 mRem 7.50E+00 mRem 1ST Qtr 3.13E-07 1.10E-04 1.10E-04 1.10E-04 1. 1OE-04 1. 10E-04 1. 10E-04 0/h ODCM 4.18E-06 1.46E-03 1.46E-03 1.46E-03 1.46E-03 1.46E-03 1.46E-03 2ND Qtr 6.64E-09 2.43E-05 2.43E-05 2.43E-05 2.43E-05 2.43E-05 2.43E-05 0/o ODCM 8.86E-08 3.24E-04 3.24E-04 3.24E-04 3.24E-04 3.24E-04 3.24E-04 3RD Qtr 0.OOE+00 3.06E-05 3.06E-05 3.06E-05 3.06E-05 3.06E-05 3.06E-05 0/0 ODCM O.OOE+00 4.08E-04 4.08E-04 4.08E-04 4.08E-04 4.08E-04 4.08E-04 4TH Qtr 4.26E-07 1.11E-04 1.11E-04 1.11E-04 1.11E-04 1.11E-04 1.11E-04%/c ODCM 5.69E-06 1.48E-03 1.48E-03 1.48E-03 1.48E-03 1.48E-03 1.48E-03 Cumulative Doses per Year Organ ODCM Bone 1.500E+01 GI-Lli 1.500E+01 Kidney 1.500E+01 Liver 1.500E+01 Lung 1.500E+01 Thyroid 1.500E+01 Total Body 1.500E+01 Units mRem mRem mRem mRem mRem mRem mRem Year to Ending 7.465E-07 2.751E-04 2.751E-04 2.751E-04 2.751E-04 2.751E-04 2.751E-04 0/0 4.977E-06 1.834E-03 1.834E-03 1.834E-03 1.834E-03 1.834E-03 1.834E-03 Receptor Limit Maximum Maximum Maximum Maximum Maximum Maximum Maximum Individual Individual Individual Individual Individual Individual Individual | |||
///////Child Child Child Child Child Child Child Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Dose Annual Dose Annual Dose Annual Dose Annual Dose Annual Dose Annual Dose Annual 1.21 1.21 1.21 1.21 1.21 1.21 1.21 Page 187 of 503 Table 2-5C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2011 Doses To A Member Of The Public Due To Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: Site Starting: | |||
1-Jan- 2011 Ending: 31-Dec-2011 Cumulative Doses Per Quarter Organ ODCM Units Bone 7.50E+00 mRem GI-Lli 7.50E+00 mRem Kidney 7.50E+00 mRem Liver 7.50E+00 mRem Lung 7.50E+00 mRem Thyroid 7.50E+00 mRem Total Body 7.50E+00 mRem 1ST Qtr 3.13E-07 1.62E-04 1.62E-04 1.62E-04 1.62E-04 1.62E-04 1.62E-04%/o ODCM 4.18E-06 2.17E-03 2.17E-03 2.17E-03 2.17E-03 2.17E-03 2.17E-03 2ND Qtr 6.64E-09 1.03E-04 1.03E-04 1.03E-04 1.03E-04 1.03E-04 1.03E-04%/o ODCM 8.86E-08 1.38E-03 1.38E-03 1.38E-03 1.38E-03 1.38E-03 1.38E-03 3RD Qtr O.OOE+00 2.52E-04 2.52E-04 2.52E-04 2.52E-04 2.52E-04 2.52E-04% ODCM 0.0OE+00 3.36E-03 3.36E-03 3.36E-03 3.36E-03 3.36E-03 3.36E-03 4TH Qtr 4.26E-07 3.37E-04 3.37E-04 3.37E-04 3.37E-04 3.37E-04 3.37E-04 0/a ODCM 5.96E-06 4.97E-03 4.97E-03 4.97E-03 4.97E-03 4.97E-03 4.97E-03 Cumulative Doses per Year Organ ODCM Bone 1.500E+01 GI-Lli 1.500E+01 Kidney 1.500E+01 Liver 1.500E+01 Lung 1.500E+01 Thyroid 1.500E+01 Total Body 1.500E+01 Units mRem mRem mRem mRem mRem mRem mRem Year to Ending Date 6.164E-04 8.909E-04 8.908E-04 8.908E-04 8.908E-04 8.908E-04 8.909E-04%/o ODCM Receptor 4.109E-03 Maximum Individual 5.939E-03 Maximum Individual 5.939E-03 Maximum Individual 5.939E-03 Maximum Individual 5.939E-03 Maximum Individual 5.939E-03 Maximum Individual 5.939E-03 Maximum Individual | |||
/ Child/ Child/ Child I Child I Child/ Child/ Child Limit Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Dose Annual Dose Annual Dose Annual Dose Annual Dose Annual Dose Annual Dose Annual 1.21 1.21 1.21 1.21 1.21 1.21 1.21 Page 188 of 503 Nuclides Released Fission & Activation Products No Nuclides Found Tritium H-3 Dissolved And Entrained Gases No Nuclides Found Gross Alpha Radioactivity G-Alpha Table 1-2A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2012 Liquid Effluents Unit: 1 Starting: | |||
1-Jan- 2012 Ending: 31-Dec-2012 Continuous Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Curies O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 Curies 9.82E-02 1.07E-01 6.30E-02 4.84E-02 Curies O.OOE+O0 O.OOE+O0 O.OOE+0O O.0OE+O0 Curies O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0*Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable concentrations. | |||
Page 189 of 503 Table 2-2C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2012 Gaseous Effluents | |||
-Mixed Mode Level Releases Unit: Site Starting: | |||
1-Jan- 2012 Ending: 31-Dec-2012 Continuous Mode Nuclides Released Fission Gases Kr-85M Xe-133 Xe- 135 Total For Period Units Curies Curies Curies 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 9.46E-02 4.75E+00 5.37E+00 1.10E-01 5.52E+00 6.24E+00 Curies O.OOE+00 0.OOE+00 1.02E+01 1.19E+01 lodines 1-131 Curies 0.OOE+00 0.DOE+00 0.OOE+00 0.OOE+00 8.94E-06 8.94E-06 0.OOE+00 O.OOE+00 Total For Period Particulates Co-58 Sr-89 Sr-90 Curies Curies O.OOE+00 1.13E-07 0.OOE+00 4.41E-07 3. 13E-08 4.73E-07 1.08E-07 3.07E-07 1.86E-08 4.34E-07 O.OOE+00 4.19E-08 O.OOE+00 4.19E-08 Curies O.OOE+00 Curies 1.13E-07 Total For Period Tritium H-3 Curies 2.62E+01 1.66E+01 8.38E+00 Gross Alpha No Nuclides Found Curies O.OOE+00 O.OOE+00 O.OOE+00*If Not Detected, Nuclide is Not Reported. | |||
Zeroes in this table indicate that no radioactivity was present at detectable levels.6.83E+00 0.OOE+00 Page 190 of 503 See Table 2-6 for typical minimum detectable concentrations. | |||
Table 2-3B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2012 Gaseous Effluents | |||
-Ground Level Releases Unit: 2 Starting: | |||
1-Jan- 2012 Ending: 31-Dec-2012 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Fission Gases No Nuclides Found Curies 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 Iodines No Nuclides Found Curies 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 Particulates No Nuclides Found Curies 0.OOE+O0 0.OOE+00 0.OOE+00 O.OOE+O0 Tritium H-3 Curies 0.OOE+00 0.OOE+O0 O.OOE+00 O.O0E+00 Gross Alpha No Nuclides Found Curies 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 Page 191 of 503 Table 2-5C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2012 Doses To A Member Of The Public Due To Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: Site Starting: | |||
1-Jan- 2012 Ending: 31-Dec-2012 Cumulative Doses Per Quarter Organ ODCM Units Bone 7.50E+00 mRem GI-Lli 7.50E+00 mRem Kidney 7.50E+00 mRem Liver 7.50E+00 mRem Lung 7.50E+00 mRem Thyroid 7.50E+00 mRem Total Body 7.50E+00 mRem 1ST Qtr 1.33E-07 5.68E-04 5.68E-04 5.68E-04 5.68E-04 5.68E-04 5.68E-04% ODCM 1.78E-06 3.63E-04 3.63E-04 3.63E-04 3.63E-04 3.63E-04 3.63E-04 2ND Qtr 1.76E-06 3.63E-04 3.63E-04 3.63E-04 3.63E-04 3.63E-04 3.63E-04% ODCM 2.35E-05 4.84E-03 4.84E-03 4.84E-03 4.84E-03 4.84E-03 4.84E-03 3RD Qtr 1. 15E-06 1.90E-04 1.90E-04 1.90E-04 1.90E-04 2.05E-04 1.90E-04 0/b ODCM 1.54E-05 2.53E-03 2.53E-03 2.53E-03 2.53E-03 2.74E-03 2.53E-03 4TH Qtr 4.93E-08 1.57E-04 1.57E-04 1.57E-04 1.57E-04 1.57E-04 1.57E-04 0/b ODCM 6.57E-07 2.09E-03 2.09E-03 2.09E-03 2.09E-03 2.09E-03 2.09E-03 Cumulative Doses per Year Organ ODCM Units Year to Ending Date 0/b ODCM Receotor Limit Bone GI-Lli Kidney Liver Lung Thyroid Total Body 1.500E+01 mRem 1.50015+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 mRem mRem mRem mRem mRem mRem 7.465E-07 8.909E-04 8.908E-04 8.908E-04 8.908E-04 8.908E-04 8.909E-04 2.064E-05 5.939E-03 5.939E-03 5.939E-03 5.939E-03 5.939E-03 5.939E-03 Maximum Individual Maximum Individual Maximum Individual Maximum Individual Maximum Individual Maximum Individual Maximum Individual | |||
/ Child/ Child/ Child/ Child/ Child I Child/ Child Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Dose Annual 1.21 Dose Annual 1.21 Dose Annual 1.21 Dose Annual 1.21 Dose Annual 1.21 Dose Annual 1.21 Dose Annual 1.21 Page 192 of 503 Appendix C VEGP ODCM Version 29 OFFSITE DOSE CALCULATION MANUAL FOR SOUTHERN NUCLEAR OPERATING COMPANY VOGTLE ELECTRIC GENERATING PLANT Version 29 February 2013 Page iii of 503 TABLE OF CONTENTS PAGE T A B LE O F C O N T E N T S ............................................................................................................... | |||
i L IS T O F T A B L E S ...................................................................................................................... | |||
iv L IS T O F F IG U R E S .................................................................................................................... | |||
vi R E F E R E N C E S ........................................................................................................................ | |||
v ii C H A PT E R 1: IN T R O D U C T IO N ............................................................................................. | |||
1-1 C HA PTER 2: LIQ U ID EFFLU ENTS ....................................................................................... | |||
2-1 2.1 LIMITS OF OPERATION 2-1 2.1.1 Liquid Effluent Monitoring Instrumentation Control 2-1 2.1.2 Liquid Effluent Concentration Control 2-7 2.1.3 Liquid Effluent Dose Control 2-10 2.1.4 Liquid Radwaste Treatment System Control 2-11 2.1.5 Major Changes to Liquid Radioactive Waste Treatment Systems 2-12 2.2 LIQUID RADWASTE TREATMENT SYSTEM 2-13 2.3 LIQUID EFFLUENT MONITOR SETPOINTS 2-17 2.3.1 General Provisions Regarding Setpoints 2-17 2.3.2 Setpoints for Radwaste System Discharge Monitors 2-19 2.3.3 Setpoints for Monitors on Normally Low-Radioactivity Streams 2-25 2.4 LIQUID EFFLUENT DOSE CALCULATIONS 2-26 2.4.1 Calculation of Dose 2-26 2.4.2 Calculation of Ai, 2-27 2.4.3 Calculation of CF~v 2-28 2.5 LIQUID EFFLUENT DOSE PROJECTIONS 2-37 2.5.1 Thirty-One Day Dose Projections 2-37 2.5.2 Dose Proiections for Specific Releases 2-37 2.6 DEFINITIONS OF LIQUID EFFLUENT TERMS 2-38 CHAPTER 3: GASEO US EFFLUENTS | |||
................................................................................. | |||
3-1 3.1 LIMITS OF OPERATION 3-1 3.1.1 Gaseous Effluent Monitoring Instrumentation Control 3-1 3.1.2 Gaseous Effluent Dose Rate Control 3-7 3.1.3 Gaseous Effluent Air Dose Control 3-10 3.1.4 Control on Gaseous Effluent Dose to a Member of the Public 3-11 3.1.5 Gaseous Radwaste Treatment System Control 3-12 3.1.6 Manor Changes to Gaseous Radioactive Waste Treatment Systems 3-13 i VER 29 TABLE OF CONTENTS (continued) | |||
PAGE 3.2 GASEOUS WASTE PROCESSING SYSTEM 3-14 3.3 GASEOUS EFFLUENT MONITOR SETPOINTS 3-20 3.3.1 General Provisions Regarding Noble Gas Monitor Setpoints 3-20 3.3.2 Setpoint for the Final Noble Gas Monitor on Each Release Pathway 3-22 3.3.3 Setpoints for Noble Gas Monitors on Effluent Source Streams 3-25 3.3.4 Determination of Allocation Factors, AG 3-27 3.3.5 Setpoints for Noble Gas Monitors with Special Requirements 3-29 3.3.6 Setpoints for Particulate and Iodine Monitors 3-29 3.4 GASEOUS EFFLUENT COMPLIANCE CALCULATIONS 3-30 3.4.1 Dose Rates at and Beyond the Site Boundary 3-30 3.4.2 Noble Gas Air Dose at or Beyond Site Boundary 3-31 3.4.3 Dose to a Member of the Public at or Beyond Site Boundary 3-35 3.4.4 Dose Calculations to Support Other Requirements 3-38 3.5 GASEOUS EFFLUENT DOSE PROJECTIONS 3-44 3.5.1 Thirty-One Day Dose Proiections 3-44 3.5.2 Dose Proiections for Specific Releases 3-45 3.6 DEFINITIONS OF GASEOUS EFFLUENT TERMS 3-46 CHAPTER 4: RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM .................... | |||
4-1 4.1 LIMITS OF OPERATION 4-1 4.1.1 Radiological Environmental Monitoring 4-1 4.1.2 Land Use Census 4-9 4.1.3 Interlaboratory Comparison Program 4-10 4.2 RADIOLOGICAL ENVIRONMENTAL MONITORING LOCATIONS 4-11 CHAPTER 5: TOTAL DOSE DETERMINATIONS | |||
.................................................................. | |||
5-1 5.1 LIMIT OF OPERATION 5-1 5.1.1 Applicabilitv 5-1 5.1.2 Actions 5-1 5.1.3 Surveillance Requirements 5-1 5.1.4 Basis 5-1 5.2 DEMONSTRATION OF COMPLIANCE 5-3 CHAPTER 6: POTENTIAL DOSES TO MEMBERS OF THE PUBLIC DUE TO THEIR ACTIVITIES INSIDE THE SITE BOUNDARY ................................................... | |||
6-1 6.1 REQUIREMENT FOR CALCULATION 6-1 6.2 CALCULATIONAL METHOD 6-1 2 VER 29 TABLE OF CONTENTS (continued) | |||
PAGE C H A PT E R 7: R E P O R T S ....................................................................................................... | |||
7-1 7.1 ANNUAL RADIOLOGICAL ENVIRONMENTAL SURVEILLANCE REPORT 7-1 7.1.1 Requirement for Report 7-1 7.1.2 Report Contents 7-1 7.2 RADIOACTIVE EFFLUENT RELEASE REPORT 7-3 7.2.1 Requirement for Report 7-3 7.2.2 Report Contents 7-3 7.3 MONTHLY OPERATING REPORT 7-6 7.4 SPECIAL REPORTS 7-6 CHAPTER 8: METEOROLOGICAL MODELS ....................................................................... | |||
8-1 8.1 ATMOSPHERIC DISPERSION 8-1 8.1.1 Ground-Level Releases 8-1 8.1.2 Elevated Releases 8-2 8.1.3 Mixed-Mode Releases 8-4 8.2 RELATIVE DEPOSITION 8-5 8.2.1 Ground-Level Releases 8-5 8.2.2 Elevated Releases 8-5 8.2.3 Mixed-Mode Releases 8-6 8.3 ELEVATED PLUME DOSE FACTORS 8-6 CHAPTER 9: METHODS AND PARAMETERS FOR CALCULATION OF GASEOUS EFFLUENT PATHWAY DOSE FACTORS, Raipj ........................................... | |||
9-1 9.1 INHALATION PATHWAY FACTOR 9-1 9.2 GROUND PLANE PATHWAY FACTOR 9-2 9.3 GARDEN VEGETATION PATHWAY FACTOR 9-3 9.4 GRASS-COW-MILK PATHWAY FACTOR 9-6 9.5 GRASS-GOAT-MILK PATHWAY FACTOR 9-9 9.6 GRASS-COW-MEAT PATHWAY FACTOR 9-12 CHAPTER 10: DEFINITIONS OF EFFLUENT CONTROL TERMS ........................................ | |||
10-1 10.1 TERMS SPECIFIC TO THE ODCM 10-1 10.2 TERMS DEFINED IN THE TECHNICAL SPECIFICATIONS 10-5 3 VER 29 LIST OF TABLES Table 2-1.Table 2-2.Table 2-3.Table 2-4.Table 2-5.Table 2-6.Table 2-7.Table 2-8.Table 3-1.Table 3-2.Table 3-3.Table 3-4.Table 3-5.Table 3-6.Table 3-7.Table 3-8.Table 3-9.Table 3-10.Table 3-11.Table 3-12.Table 4-1.Radioactive Liquid Effluent Monitoring Instrumentation Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements Radioactive Liquid Waste Sampling and Analysis Program Applicability of Liquid Monitor Setpoint Methodologies Parameters for Calculation of Doses Due to Liquid Effluent Releases Element Transfer Factors Adult Ingestion Dose Factors Site-Related Ingestion Dose Factors, AT, Radioactive Gaseous Effluent Monitoring Instrumentation Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements Radioactive Gaseous Waste Sampling and Analysis Program Applicability of Gaseous Monitor Setpoint Methodologies Dose Factors for Exposure to a Semi-Infinite Cloud of Noble Gases Dose Factors for Exposure to Direct Radiation from Noble Gases in an Elevated Finite Plume Attributes of the Controlling Receptor Raipj for Ground Plane Pathway, All Age Groups Raipj for Inhalation Pathway, Child Age Group Raipj for Inhalation Pathway, Adult Age Group Raipj for Cow Meat Pathway, Child Age Group Raipj for Garden Vegetation, Child Age Group Radiological Environmental Monitoring Program PAGE 2-3 2-5 2-8 2-18 2-30 2-31 2-32 2-35 3-3 3-5 3-8 3-21 3-33 3-34 3-37 3-39 3-40 3-41 3-42 3-43 4-3 4 VER 29 LIST OF TABLES (Continued) | |||
Table 4-2.Table 4-3.Table 4-4.Table 4-5 Table 6-1.Table 8-1.Table 9-1.Table 9-2.Table 9-3.Table 9-4.Table 9-5.Table 9-6.Table 9-7.Table 9-8.Table 9-9.Table 9-10.Table 9-11.Table 9-12.Table 9-13.Table 9-14.Table 9-15.Reporting Levels for Radioactivity Concentrations in Environmental Samples Values for the Minimum Detectable Concentration (MDC)Radiological Environmental Monitoring Locations Groundwater Monitoring Locations Attributes of Member of the Public Receptor Locations Inside the Site Boundary Terrain Elevation Above Plant Site Grade Miscellaneous Parameters for the Garden Vegetation Pathway Miscellaneous Parameters for the Grass-Cow-Milk Pathway Miscellaneous Parameters for the Grass-Goat-Milk Pathway Miscellaneous Parameters for the Grass-Cow-Meat Pathway Individual Usage Factors Stable Element Transfer Data Inhalation Dose Factors for the Infant Age Group Inhalation Dose Factors for the Child Age Group Inhalation Dose Factors for the Teenager Age Group Inhalation Dose Factors for the Adult Age Group Ingestion Dose Factors for the Infant Age Group Ingestion Dose Factors for the Child Age Group Ingestion Dose Factors for the Teenager Age Group Ingestion Dose Factors for the Adult Age Group External Dose Factors for Standing on Contaminated Ground PAGE 4-7 4-8 4-12 4-15 6-2 8-7 9-5 9-8 9-11 9-14 9-15 9-16 9-17 9-20 9-23 9-26 9-29 9-32 9-35 9-38 9-41 5 VER 29 LIST OF FIGURES Figure 2-1.Figure 2-2.Figure 2-3.Figure 3-1.Figure 3-2.Figure 3-3.Figure 3-4.Figure 3-5.Figure 4-1.Figure 4-2.Figure 4-3.Figure 4-4.Figure 4-5 Figure 8-1.Figure 8-2.Figure 8-3.Figure 8-4.Figure 8-5.Figure 8-6.Figure 8-7.Figure 8-8.Figure 8-9.Figure 8-10.Unit 1 Liquid Radwaste Treatment System Unit 2 Liquid Radwaste Treatment System Liquid Radwaste Discharge Pathways Schematic Diagram of the Gaseous Radwaste Treatment System Schematic Diagram of the Unit 1 Plant Vent Release Pathway Schematic Diagram of the Unit 2 Plant Vent Release Pathway Schematic Diagram of the Turbine Building Vent Release Pathway (Typical of Both Units)Schematic Diagram of the Radwaste Processing Facility Ventilation Release Pathway Terrestrial Stations Near Site Boundary Terrestrial Stations and Aquatic Stations, 0-5 Miles Terrestrial Stations Beyond 5 Miles Drinking Water Stations Groundwater Monitoring Wells Vertical Standard Deviation of Material in a Plume (a,)Terrain Recirculation Factor (Kr)Plume Depletion Effect for Ground Level Releases Plume Depletion Effect for 30-Meter Releases Plume Depletion Effect for 60-Meter Releases Plume Depletion Effect for 100-Meter Releases Relative Deposition for Ground-Level Releases Relative Deposition for 30-Meter Releases Relative Deposition for 60-Meter Releases Relative Deposition for 100-Meter (or Greater) Releases PAGE 2-14 2-15 2-16 3-15 3-16 3-17 3-18 3-19 4-16 4-17 4-18 4-19 4-20 8-8 8-9 8-10 8-11 8-12 8-13 8-14 8-15 8-16 8-17 6 VER 29 REFERENCES | |||
: 1. J.S. Boegli, R.R. Bellamy, W.L. Britz, and R.L. Waterfield, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants," NUREG-0133, October 1978.2. "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR 50, Appendix I," U.S. NRC Regulatory Guide 1.109, March 1976.3. "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR 50, Appendix I," U.S. NRC Regulatory Guide 1.109, Revision 1, October 1977.4. "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors," U.S. NRC Regulatory Guide 1.111, March 1976.5. "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors," U.S. NRC Regulatory Guide 1.111, Revision 1, July 1977.6. "Estimating Aquatic Dispersion of Effluents from Accidental and Routine Reactor Releases for the Purpose of Implementing Appendix I," U.S. NRC Regulatory Guide 1.113, April 1977.7. W.R. Stokes Ill, T.W. Hale, J.L. Pearman, and G.R. Buell, "Water Resources Data, Georgia, Water Year 1983," U.S. Geological Survey Water Data Report GA-83-1, June 1984.8. Direct communication with the Water Resources Division, U.S. Geological Survey, U.S.Department of the Interior, February 1985.9. Bernd Kahn, et al., "Bioaccumulation of P-32 in Bluegill and Catfish," NUREG/CR-3981, February 1985.10. Memo from S.E. Ewald, Georgia Power Company, to C.C. Eckert, Georgia Power Company, May 9, 1988.11. Voqtle Electric Generating Plant Units 1 and 2 Final Safety Analysis Report, Georgia Power Company.12. Voqtle Electric Generating Plant Units 1 and 2 Environmental Report -Operating License Stage, Georgia Power Company.13. Memo from A.C. Stalker, Georgia Power Company, to D.F. Hallman, Georgia Power Company, May 9, 1988.14. Voaqtle Electric Generating Plant Land Use Survey -1988, Georgia Power Company, April 1988.15. Letter to Southern Company Services from Pickard, Lowe, and Garrick, Inc., Washington, D.C., April 27,1988.7 VER 29 | |||
: 16. Letter to Bill Ollinger, Georgia Power Company, from T.L. Broadwell, Georgia Power Company, Atlanta, Georgia, June 22, 1988.17. Letter to Bill Ollinger, Georgia Power Company, from R.D. Just, Georgia Power Company, Atlanta, Georgia, July 8, 1988.18. L.A. Currie, Lower Limit of Detection: | |||
Definition and Elaboration of a Proposed Position of Radiolo-gical Effluent and Environmental Measurements, U.S. NRC Report NUREG/CR-4007, 1984.19. "Radiological Assessment Branch Technical Position," U.S. Nuclear Regulatory Commission, Revision 1, November 1979.20. D.C. Kocher, "Radioactive Decay Data Tables," U.S. DOE Report DOE/TIC-11026, 1981.21. J.E. Till and H.R. Meyer, eds., Radiological Assessment, U.S. NRC Report NUREG/CR-3332, 1983.22. Letter to Bill Ollinger, Southern Nuclear Operating Company, from Gary D. Johnson, Georgia Power Company, December 21, 1995.23. Letter to Mary Beth Lloyd, Southern Nuclear Operating Company, from Steven Bearce, Southern Company Services, February 2, 2009.8 VER 29 VEGP ODCM CHAPTER 1 INTRODUCTION The Offsite Dose Calculation Manual is a supporting document of the Technical Specifications. | |||
As such, it describes the methodology and parameters to be used in the calculation of offsite doses due to radioactive liquid and gaseous effluents, and in the calculation of liquid and gaseous effluent monitoring instrumentation alarm setpoints. | |||
In addition, it contains the following: | |||
* The controls required by the Technical Specifications, governing the radioactive effluent and radiological environmental monitoring programs.* Schematics of liquid and gaseous radwaste effluent treatment systems, which include designation of release points to UNRESTRICTED AREAS.* A list and maps indicating the specific sample locations for the Radiological Environmental Monitoring Program." Specifications and descriptions of the information that must be included in the Annual Radiological Environmental Operating Report and the Radioactive Effluent Release Report required by the Technical Specifications. | |||
The ODCM will be maintained at the plant for use as a reference guide and training document of accepted methodologies and calculations. | |||
Changes in the calculational methods or parameters will be incorporated into the ODCM in order to ensure that it represents current methodology in all applicable areas. Any computer software used to perform the calculations described will be maintained current with the ODCM.Equations and methods used in the ODCM are based on those presented in NUREG-0133 (Reference 1), in Regulatory Guide 1.109 (References 2 and 3), in Regulatory Guide 1.111 (References 4 and 5), and in Regulatory Guide 1.113 (Reference 6).1-1 VER 29 VEGP ODCM CHAPTER 2 LIQUID EFFLUENTS 2.1 LIMITS OF OPERATION The following Liquid Effluent Controls implement requirements established by Technical Specifications Section 5.0. Terms printed in all capital letters are defined in Chapter 10.2.1.1 Liquid Effluent Monitoring Instrumentation Control In accordance with Technical Specification 5.5.4.a, the radioactive liquid effluent monitoring instrumentation channels shown in Table 2-1 shall be OPERABLE with their alarm/trip setpoints set to ensure that the limits specified in Section 2.1.2 are not exceeded. | |||
The alarm/trip setpoints of these channels shall be determined in accordance with Section 2.3.2.1.1.1 Applicability This limit applies at all times.2.1.1.2 Actions With a radioactive liquid effluent monitoring instrumentation channel alarm/trip setpoint less conservative than required by the above control, immediately suspend the release of radioactive liquid effluents monitored by the affected channel, declare the channel inoperable, or change the setpoint to a conservative value.With less than the minimum number of radioactive liquid effluent monitoring instrumentation channels OPERABLE, take the ACTION shown in Table 2-1. Restore the INOPERABLE instrumentation to OPERABLE status within 30 days, or if unsuccessful, explain in the next Radioactive Effluent Release Report, per Technical Specification 5.6.3, why this inoperability was not corrected in a timely manner.This control does not affect shutdown requirements or MODE changes.2.1.1.3 Surveillance Requirements Each radioactive liquid effluent monitoring instrumentation channel shall be demonstrated OPERABLE by performance of the CHANNEL CHECK, SOURCE CHECK, CHANNEL CALIBRATION, and CHANNEL OPERATIONAL TEST operations at the frequencies shown in Table 2-2. Specific instrument numbers are provided in parentheses for information only. The numbers apply to each unit. These numbers will help to identify associated channels or loops and are not intended to limit the requirements to the specific instruments associated with the number.2-1 VER 29 2-1 VER 29 VEGP ODCM 2.1.1.4 Basis The radioactive liquid effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in liquid effluents during actual or potential releases of liquid effluents. | |||
The Alarm/Trip Setpoints for these instruments shall be calculated and adjusted in accordance with the methodology and parameters in Section 2.3 to ensure that the alarm/trip will occur prior to exceeding the limits of Section 2.1.2. The OPERABILITY and use of this instrumentation is consistent with the requirements of General Design Criteria 60, 63, and 64 of Appendix A to 10 CFR Part 50.2-2 VER 29 VEGP ODCM Table 2-1. Radioactive Liquid Effluent Monitoring Instrumentation OPERABILITY Requirementsa Instrument Minimum Channels Operable ACTION 1. Radwaste Monitors Providing Alarm and Automatic Termination of Release a. Liquid Radwaste Effluent Line (RE-0018) 1 37 b. Steam Generator Blowdown Effluent Line 1 38 (RE-0021)c. Turbine Building Effluent Line (RE-0848) 1 38 2. Radwaste Monitors Providing Alarm, but Not Automatic Termination of Release NSCW Effluent Line (RE-0020 A) 1 39 NSCW Effluent Line (RE-0020 B) 1 39 3. Flowrate Measurement Devices a. Liquid Radwaste Effluent Line (FT-0018), 1 40 (FT-1084A1B), or (FT-1085A/B) | |||
: b. Steam Generator Blowdown Effluent Line 1 40 (FT-0021)c. Flow to Blowdown Sump (AFQI-7620, F17620A) 1 40 a. All requirements in this table apply to each unit.2-3 VER 29 VEGP ODCM Table 2-1 (contd). Notation for Table 2-1 -ACTION Statements ACTION 37 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases may continue provided that prior to initiating a release: a. The local radiation monitor reading (if functional) is recorded at least once per 12 hours during the release or at least two independent samples are analyzed in accordance with Section 2.1.2.3, and b. At least two technically qualified members of the Facility Staff independently verify the discharge line valving and the release rate calculations. | |||
Otherwise, suspend release of radioactive effluents via this pathway.ACTION 38 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway may continue provided the local radiation monitor reading (if functional) is recorded at least once per 12 hours or grab samples are analyzed for gross radioactivity at a MINIMUM DETECTABLE CONCENTRATION no higher than 1 x 10-7 ltCi/mL using gross beta/gamma counting or 5 x 10-7 ýiCi/mL for the principal gamma emitters using gamma-ray spectroscopy. | |||
: a. At least once per 12 hours when the specific activity of the secondary coolant is greater than 0.01 pCi/gram DOSE EQUIVALENT 1-131.b. At least once per 24 hours when the specific activity of the secondary coolant is less than or equal to 0.01 fiCi/gram DOSE EQUIVALENT I-131.ACTION 39 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway may continue provided that, at least once per 12 hours, the local radiation monitor reading (if functional) is recorded or grab samples are collected and analyzed for radioactivity at a MINIMUM DETECTABLE CONCENTRATION no higher than 1 x 10-7 ItCi/mL using gross beta/gamma counting or 5 x 10-7 RtCi/mL for the principal gamma emitters using gamma-ray spectroscopy. | |||
ACTION 40 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway 2-4 VER 29 VEGP ODCM may continue provided the flowrate is estimated at least once per 4 hours during actual releases. | |||
Pump curves generated in place may be used to estimate flow.2-5 VER29 2-5 VER 29 VEGP ODCM Table 2-2. Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements Surveillance Requirementsd CHANNEL CHANNEL Instrument CHANNEL SOURCE CALIBRA- OPERATIONAL CHECK CHECK TION TEST 1. Radwaste Monitors Providing Alarm and Automatic Termination of Release a. Liquid Radwaste Effluent Line (RE-0018) | |||
D P Rb Ra(l)b. Steam Generator Blowdown Effluent Line (RE-0021) | |||
D M Rb Ra(l)c. Turbine Building Effluent Line (RE-0848) | |||
D M Rb Ra(l)2. Radwaste Monitors Providing Alarm, but Not Automatic Termination of Release NSCW Effluent Line (RE-0020 A&B) D M Rb Ra(2)3. Flowrate Measurement Devices a. Liquid Radwaste Effluent Line (FT-001 8), (FT-1084A/B), or (FT- 1085A/B) Dc NA R NA b. Steam Generator Blowdown Effluent Line (FT-0021) | |||
Dc NA R NA c. Flow to Blowdown Sump (AFQI-7620, F17620A) Dc NA R Q 2-5 VER 29 VEGP ODCM Table 2-2 (contd). Notation for Table 2-2 a. In addition to the basic functions of a CHANNEL OPERATIONAL TEST (Section 10.2): (1) The CHANNEL OPERATIONAL TEST shall also demonstrate that automatic isolation of this pathway and control room annunciation occurs (for item a. below only); and control room CRT indication occurs (if any of the following conditions exist): (a) Instrument indicates measured levels above the alarm/trip setpoint;(b) Instrument indicates an "Equipment Trouble" alarm;(c) Instrument indicates a "Low" alarm; or (d) Instrument indicates channel "Deactivated". | |||
(2) The CHANNEL OPERATIONAL TEST shall also demonstrate that control room annunciation occurs (for item a. below only); and that control room CRT indication occurs (if any of the following conditions exist): (a) Instrument indicates measured levels above the alarm/trip setpoint;(b) Instrument indicates an "Equipment Trouble" alarm;(c) Instrument indicates a "Low" alarm; or (d) Instrument indicates channel "Deactivated". | |||
: b. The initial CHANNEL CALIBRATION shall be performed using one or more of the reference standards certified by the National Institute of Standards and Technology or using standards that have been obtained from suppliers that participate in measurements assurance activities with NIST. These standards shall permit calibrating the system over its intended range of energy and measurement range. For subsequent CHANNEL CALIBRATION, sources that have been related to the initial calibration shall be used.c. CHANNEL CHECK shall consist of verifying indication of flow during periods of release. CHANNEL CHECK shall be made at least once per 24 hours on days on which continuous, periodic, or batch releases are made.2-6 VER 29 VEGP ODCM d. All requirements in this table apply to each unit.2-7 VER 29 VEGP ODCM 2.1.2 Liquid Effluent Concentration Control In accordance with Technical Specifications 5.5.4.b and 5.5.4.c, the concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS shall be limited at all times to ten times the concentrations specified in 10 CFR 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 1 x 10 -4 pCi/mL total activity.2.1.2.1 Applicability This limit applies at all times.2.1.2.2 Actions With the concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS exceeding the limits stated in Section 2.1.2, immediately restore the concentration to within the stated limits.This control does not affect shutdown requirements or MODE changes.2.1.2.3 Surveillance Requirements The radioactivity content of each batch of radioactive liquid waste shall be determined by sampling and analysis in accordance with Table 2-3. The results of radioactive analyses shall be used with the calculational methods in Section 2.3 to assure that the concentration at the point of release is maintained within the limits of Section 2.1.2.2.1.2.4 Basis This control is provided to ensure that the concentration of radioactive materials released in liquid waste effluents to UNRESTRICTED AREAS will be less than ten times the concentration levels specified in 10 CFR 20, Appendix B, Table 2, Column 2.This limitation provides additional assurance that the levels of radioactive materials in bodies of water in UNRESTRICTED AREAS will result in exposures within (1) the Section II.A design objectives of Appendix 1, 10 CFR 50, to a MEMBER OF THE PUBLIC, and (2) the limits of 10 CFR 20.1301 to the population. | |||
The concentration limit for dissolved or entrained noble gases is based upon the assumption that Xe-1 35 is the controlling radioisotope and its MPC in air (submersion) was converted to an equivalent concentration in water using the methods described in International Commission on Radiological Protection (ICRP) Publication 2 (1959). The resulting concentration of 2 x 104 was then multiplied by the ratio of the effluent concentration limit for Xe-1 35, stated in Appendix B, Table 2, Column 1 of 10 CFR 20 (paragraphs 20.1001 to 20.2401), to the MPC for Xe-135, stated in Appendix B, Table II, Column 1 of 10 CFR 20 (paragraphs 20.1 to 20.601), to obtain the limiting concentration of 1 x 104 ptCi/mL.2-7 VER 29 VEGP ODCM 2-8 VER29 2-8 VER 29 VEGP ODCM Table 2-3.Radioactive Liquid Waste Sampling and Analysis Program_-_ Sam pling and Analysis Requirementsa b MINIMUM MINIMUM DETECTABLE CONCENTRA-Minimum TO MC Liquid Release Sampling Analysis Type of Activity TION (MDC)Type FREQUENCY FREQUENCY Analysis (jiCi/mL)A. BATCH RELEASES PRINCIPAL 5 E-7 GAMMA EMITTERS P P Each BATCH Each BATCH 1-131 1 E-6 1. Waste Monitor Dissolved and 1 E-5 Tank p Entrained Gases One BATCH/M M (Gamma Emitters)2. Drainage of H-3 I E-5 System P M Each BATCH COMPOSITE Gross Alpha 1 E-7 Sr-89, Sr-90 5 E-8 P Q Each BATCH COMPOSITE Fe-55 I E-6 B. CONTINUOUS RELEASES PRINCIPAL 5 E-7 GAMMA EMITTERS W Continuous COMPOSITE 1-131 1 E-6 Dissolved and 1 E-5 M Entrained Gases Grab Sample M (Gamma Emitters)Waste Water H-3 1 E-5 Retention Basinc M Continuous COMPOSITE Gross Alpha 1 E-7 Sr-89, Sr-90 5 E-8 Q Continuous COMPOSITE Fe-55 1 E-6 2-8 VER 29 VEGP ODCM Table 2-3 (contd). Notation for Table 2-3 a. All requirements in this table apply to each unit.b. Terms printed in all capital letters are defined in Chapter 10.c. The VVWRB will not be considered a release point until there is a confirmed primary to secondary leak. Once a primary to secondary leak has been confirmed, this composite shall be analyzed as specified until the leak is repaired. | |||
This surveillance will continue until three consecutive weekly composite samples have shown no activity above the MDC.2-10 VER 29 VEGP ODCM 2-10 VER 29 VEGP ODCM 2.1.3 Liquid Effluent Dose Control In accordance with Technical Specifications 5.5.4.d and 5.5.4.e, the dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive materials in liquid effluents released, from each unit, to UNRESTRICTED AREAS shall be limited: a. During any calendar quarter to less than or equal to 1.5 mrem to the total body and to less than or equal to 5 mrem to any organ, and b. During any calendar year to less than or equal to 3 mrem to the total body and to less than or equal to 10 mrem to any organ.2.1.3.1 Applicability These limits apply at all times.2.1.3.2 Actions With the calculated dose from the release of radioactive materials in liquid effluents exceeding any of the limits of Section 2.1.3., prepare and submit to the Nuclear Regulatory Commission within 30 days a special report which identifies the cause(s) for exceeding the limit(s); | |||
defines the corrective actions to be taken to reduce the releases;and defines the proposed corrective actions to be taken to assure that subsequent releases will be in compliance with the limits of Section 2.1.3.This control does not affect shutdown requirements or MODE changes.2.1.3.3 Surveillance Requirements At least once per 31 days, cumulative dose contributions from liquid effluents for the current calendar quarter and the current calendar year shall be determined, for each unit, in accordance with Section 2.4.2.1.3.4 Basis This control is provided to implement the requirements of Sections II.A, III.A and IV.A of Appendix 1, 10 CFR Part 50. The limits stated in Section 2.1.3 implement the guides set forth in Section Il.A of Appendix I. The ACTIONS stated in Section 2.1.3.2 provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive material in liquid effluents will be kept "as low as is reasonably achievable." Also, for fresh water sites with drinking water supplies that can be potentially affected by plant operations, there is reasonable assurance that the operation of the facility will not result in radionuclide concentrations in the finished drinking water that are in excess of the requirements of 40 CFR Part 141. The dose calculations in Section 2.4 implement the requirements in 2-10 VER 29 VEGP ODCM Section III.A of Appendix I, which state that conformance with the guides of Appendix I be shown by calculational procedures based on models and data, such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated. | |||
The equations specified in Section 2.4 for calculating the doses due to the actual release rates of radioactive materials in liquid effluents are consistent with the 2-11 VER 29 VEGP ODCM methodology provided in Regulatory Guide 1.109 (Reference | |||
: 3) and Regulatory Guide 1.113 (Reference 6).This control applies to the release of liquid effluents from each unit at the site. The liquid effluents from shared LIQUID RADWASTE TREATMENT SYSTEMs are to be proportioned between the units.2.1.4 Liquid Radwaste Treatment System Control In accordance with Technical Specification 5.5.4.f, the LIQUID RADWASTE TREATMENT SYSTEM shall be OPERABLE. | |||
The appropriate portions of the system shall be used to reduce radioactivity in liquid wastes prior to their discharge when the projected doses due to the liquid effluent, from each unit, to UNRESTRICTED AREAS would exceed 0.06 mrem to the total body or 0.2 mrem to any organ of a MEMBER OF THE PUBLIC in 31 days.2.1.4.1 Applicability This limit applies at all times.2.1.4.2 Actions With radioactive liquid waste being discharged without treatment and in excess of the above limits and any portion of the LIQUID RADWASTE TREATMENT SYSTEM not in operation, prepare and submit to the Nuclear Regulatory Commission within 30 days a special report which includes the following information: | |||
: a. Explanation of why liquid radwaste was being discharged without treatment, identification of any inoperable equipment or subsystems and the reason for the inoperability, b. Action(s) taken to restore the inoperable equipment to OPERABLE status, and c. Summary description of action(s) taken to prevent a recurrence. | |||
This control does not affect shutdown requirements or MODE changes.2.1.4.3 Surveillance Requirements Doses due to liquid releases to UNRESTRICTED AREAS shall be projected at least once per 31 days, in accordance with Section 2.5, during periods in which the LIQUID RADWASTE TREATMENT SYSTEMs are not being fully utilized.The LIQUID RADWASTE TREATMENT SYSTEM shall be demonstrated OPERABLE by meeting the controls of Sections 2.1.2 and 2.1.3.2-11 VER 29 VEGP ODCM 2.1.4.4 Basis The OPERABILITY of the LIQUID RADWASTE TREATMENT SYSTEM ensures that this system will be available for use whenever liquid effluents require treatment prior to release to the UNRESTRICTED AREAS. The requirement that the appropriate portions of this system be used when specified provides assurance that the releases of radioactive materials in liquid effluents will be kept "as low as is reasonably achievable." This control implements the requirements of 10 CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR Part 50, and the design objective given in Section lI.D of Appendix I to 10 CFR Part 50. The specified limits governing the use of appropriate portions of the LIQUID RADWASTE TREATMENT SYSTEM were specified as a suitable fraction of the dose design objectives set forth in Section II.A of Appendix 1, 10 CFR Part 50, for liquid effluents. | |||
This control applies to the release of radioactive materials in liquid effluents from each unit at the site. For units with shared radwaste systems, the liquid effluents from the shared system are to be proportioned among the units sharing that system.2.1.5 Major Changes to Liquid Radioactive Waste Treatment Systems Licensee initiated MAJOR CHANGES TO LIQUID RADIOACTIVE WASTE TREATMENT SYSTEMS: a. Shall be reported to the Nuclear Regulatory Commission in the Radioactive Effluent Release Report for the period in which the change was implemented. | |||
The discussion of each change shall contain the information described in Section 7.2.2.7.b. Shall become effective upon review and approval by the Vice President | |||
-Plant.2-12 VER 29 VEGP ODCM 2.2 LIQUID RADWASTE TREATMENT SYSTEM The Vogtle Electric Generating Plant is located on the west bank of the Savannah River approximately 151 river miles from the Atlantic Ocean. There are two pressurized water reactors on the site. Each unit is served by a separate LIQUID RADWASTE TREATMENT SYSTEM; however, certain components are shared between the two systems. Schematics of the LIQUID RADWASTE TREATMENT SYSTEMs are presented in Figure 2-1 and Figure 2-2. Liquid discharge pathways are shown in Figure 2-3.All liquid radwastes treated by the LIQUID RADWASTE TREATMENT SYSTEM are collected in 5,000-gallon or 20,000-gallon waste monitor tanks. Releases from the waste monitor tanks are to the discharge line from the blowdown sump, and from there to the Savannah River. The blowdown sump also receives input from the waste water retention basins, turbine plant cooling water blowdown, and nuclear service cooling water blowdown. | |||
Additional dilution water is available from the cooling tower makeup water bypass line.Although no significant quantities of radioactivity are expected in the nuclear service cooling water, the steam generator blowdown processing system, or the turbine building drain system, these effluent pathways are monitored as a precautionary measure. The monitors serving the latter two pathways provide for automatic termination of releases from these systems in the event that radioactivity is detected above predetermined levels. These two systems discharge to the waste water retention basin. Sampling and analysis of releases via all three of these pathways must be sufficient to ensure that the liquid effluent dose limits specified in the controls of Section 2.1.3 are not exceeded.2-13 VER 29 VEGP ODCM To Unit 2 Filter Demin Waste Monitor Waste Monitor Tank: Tank: 5,000 gal 20,000 gal I I To Figure 2-1. Unit 1 Liquid Radwaste Treatment System 2-14 VER 29 VEGP ODCM from Laundry and Hot Shower Tank (Unit 1)Filter D ni n i Waste Monitor Waste Monitor Tank: Tank: 5,000 gal 20,000 gal To Discharge Figure 2-2. Unit 2 Liquid Radwaste Treatment System 2-15 VER 29 VEGP ODCM River Radioactivity Monitors 0 1(2) RE0020 0 1(2) REO021 0 1(2) RE0848 G 1(2) RE0018*The blowdown gump is common to both units.Figure 2-3. Liquid Radwaste Discharge Pathways 2-16 VER 29 VEGP ODCM 2.3 LIQUID EFFLUENT MONITOR SETPOINTS 2.3.1 General Provisions Regarding Setpoints Liquid monitor setpoints calculated in accordance with the methodology presented in this section will be regarded as upper bounds for the actual high alarm setpoints. | |||
That is, a lower value for the high alarm setpoint may be established or retained on the monitor, if desired. Intermediate level setpoints should be established at an appropriate level to give sufficient warning prior to reaching the high alarm setpoint. | |||
If no release is planned for a particular pathway, or if there is no detectable activity in the planned release, the monitor setpoint should be established as close to background as practical to prevent spurious alarms, and yet alarm should an inadvertent release occur.Two basic setpoint methodologies are presented below. For radwaste system discharge monitors, setpoints are determined to assure that the limits of Section 2.1.2 are not exceeded. | |||
For monitors on streams that are not expected to contain significant radioactivity, the purpose of the monitor setpoints is to cause an alarm on low levels of radioactivity, and to terminate the release where this is possible. | |||
Section 2.1.1 establishes the requirements for liquid effluent monitoring instrumentation. | |||
Table 2-4 lists the monitors for which each of the setpoint methodologies is applicable. | |||
2-17 VER 29 VEGP ODCM Table 2-4. Applicability of Liquid Monitor Setpoint Methodologies Liquid Radwaste Discharge Monitors Setpoint Method: Section 2.3.2 Release Type: BATCH Unit I or Unit 2 Liquid Waste Treatment System Effluent Monitor: 1RE-0018 / 2RE-0018 Normally Low-Radioactivity Streams with Termination or Diversion upon Alarm Setpoint Method: Section 2.3.3 Release Type: CONTINUOUS Unit 1 or Unit 2 Steam Generator Blowdown Effluent Monitor: 1 RE-0021 / 2RE-0021 Unit 1 or Unit 2 Turbine Building Drain Effluent Monitor: 1 RE-0848 / 2RE-0848 Normally Low-Radioactivity Streams with Alarm Only Setpoint Method: Section 2.3.3 Release Type: CONTINUOUS Unit 1 or Unit 2 Nuclear Service Cooling Water System Effluent Monitors (2 per unit): 1RE-0020 A and B 2RE-0020 A and B 2-18 VER 29 VEGP ODCM 2.3.2 Setpoints for Radwaste System Discharge Monitors 2.3.2.1 Overview of Method LIQUID RADWASTE TREATMENT SYSTEM effluent line radioactivity monitors are intended to provide alarm and automatic termination of release prior to exceeding the limits specified in Section 2.1.2 at the point of release of the diluted effluent into the UNRESTRICTED AREA. Therefore, their alarm/trip setpoints are established to ensure compliance with the following equation (equation adapted from Addendum to Reference 1): c'f- <- TF" CECL (2.1)F+f where: CECL = the Effluent Concentration Limit corresponding to the mix of radionuclides in the effluent being considered for discharge, in g.Ci/mL.c = the setpoint, in jgCi/mL, of the radioactivity monitor measuring the concentration of radioactivity in the effluent line prior to dilution and subsequent release. The setpoint represents a concentration which, if exceeded, could result in concentrations exceeding the limits of Section 2.1.2 in the UNRESTRICTED AREA.f = the effluent flowrate at the location of the radioactivity monitor, in gpm.F = the dilution stream flowrate which can be assured prior to the release point to the UNRESTRICTED AREA, in gpm. A predetermined dilution flowrate must be assured for use in the calculation of the radioactivity monitor setpoint.TF = the tolerance factor selected to allow flexibility in the establishment of a practical monitor setpoint which could accommodate effluent releases at concentrations higher than the ECL values stated in 10 CFR 20, Appendix B, Table 2, Column 2; the tolerance factor must not exceed a value of 10.While equation (2.1) shows the relationships of the critical parameters that determine the setpoint, it cannot be applied practically to a mixture of radionuclides with different Effluent Concentration Limits (ECLs). For a mixture of radionuclides, equation (2.1) is satisfied in a practicable manner based on the calculated ECL fraction of the radionuclide mixture and the dilution stream flowrate that can be assured for the 2-19 VER 29 VEGP ODCM duration of the release (Fd), by calculating the maximum permissible effluent flowrate (fin) and the radioactivity monitor setpoint (c).The setpoint method presented below is applicable to the release of only one tank of liquid radwaste per reactor unit at a given time. Liquid releases must be controlled administratively to ensure that this condition is met; otherwise, the setpoint method may not ensure that the limits of Section 2.1.2 are not exceeded.2.3.2.2 Setpoint Calculation Steps Step 1: Determine the radionuclide concentrations in the liquid waste being considered for release in accordance with the sampling and analysis requirements of Section 2.1.2.All liquid radwastes treated by the LIQUID RADWASTE TREATMENT SYSTEM are collected in waste monitor tanks for sampling and analysis. | |||
The 5,000-gallon waste monitor tanks are recirculated for a minimum of 30 minutes, and the 20,000-gallon waste monitor tanks are recirculated for a minimum of 45 minutes. This mixing assures that a representative sample can be taken from the tank.The total concentration of the liquid waste is determined by the results of all required analyses on the collected sample, as follows: YZCi = C + ZC +Cf + + c + YICg (2.2)s g where: C, = the gross concentration of alpha emitters in the liquid waste, not less than that measured in the most recent applicable composite sample.Cs = the concentration of strontium radioisotope s (Sr-89 or Sr-90) in the liquid waste, not less than that measured in the most recent applicable composite sample.Cf = the concentration of Fe-55 in the liquid waste, not less than that measured in the most recent applicable composite sample.Ct = the concentration of H-3 in the liquid waste, not less than that measured in the most recent applicable composite sample.Cg = the concentration of gamma emitter g in the liquid waste as measured by gamma ray spectroscopy performed on the sample for the release under consideration. | |||
The Cg term will be included in the analysis of each waste sample; terms for gross concentrations of alpha emitters, Sr-89, Sr-90, Fe-55, and tritium will be included in 2-20 VER 29 VEGP ODCM accordance with the sampling and analysis program required for the waste stream (see Section 2.1.2). For each analysis, only radionuclides identified and detected above background for the given measurement should be included in the calculation. | |||
When using the alternate setpoint methodology of step 5.b, the historical maximum values of Ca, Cs, Cf, and Ct shall be used.Step 2: Determine the required dilution factor for the mix of radionuclides detected in the waste.Measured radionuclide concentrations are used to calculate ECL fractions. | |||
The ECL fractions are used along with a safety factor to calculate the required dilution factor; this is the minimum ratio of dilution flowrate to waste flowrate that must be maintained throughout the release to ensure that the limits of Section 2.1.2 are not exceeded at the point of discharge into the UNRESTRICTED AREA. The required dilution factor, RDF, is calculated as the sum of the dilution factors required for gamma emitters (RDFy) and for non-gamma-emitters (RDFny): RDF = YCL+ [(SF)(TF)I (2.3)= RDFY + RDF,,y RDF), = (sFCr) (2.4)(SFXTF)where: SC" Cf C,'C+ + +RDF,,, = ECL, ECL,. ECL ECL,j (2.5)(SF)(TF )C = the measured concentration of radionuclide i as defined in step 1, in J4Ci/mL. The Ca, Cs, Cf, and Ct terms will be included in the calculation as appropriate. | |||
ECL = the Effluent Concentration Limit for radionuclide i from 10 CFR Part 20, Appendix B, Table 2, Column 2 (except for noble gases as discussed below). In the absence of information regarding the solubility classification of a given radionuclide in the waste stream, the solubility class with the lowest ECL shall be assumed. For dissolved or entrained noble gases, the concentration shall be limited to 1x10- ptCi/mL. For gross alpha, the ECL shall be 2x1 0-9 tCi/mL; if specific alpha-emitting radionuclides are measured, the ECL for the specific radionuclide(s) should be used.2-21 VER 29 VEGP ODCM SF = the safety factor selected to compensate for statistical fluctuations and errors of measurement. | |||
The value for the safety factor must be between 0 and 1. A value of 0.5 is reasonable for liquid releases; a more precise value may be developed if desired.TF = the tolerance factor (as defined in Section 2.3.2.1).Step 3: Determine the release-specific assured dilution stream flowrate.Determine the dilution stream flowrate that can be assured during the release period, designated Fd; this value is the setpoint for the dilution stream flowrate measurement device.If simultaneous radioactive releases are planned from the same or different reactor units, the dilution stream must be allocated among all the simultaneous releases. | |||
There will only be one such release per unit at a given time, unless there is detectable radioactivity in one of the normally low-radioactivity streams (see Section 2.3.3).Allocation of the dilution stream to multiple release paths is accomplished as follows: F:O, = Fd (AFP) (2.6)where: Fdp = the dilution flowrate allocated to release pathway p, in gpm.AFp = the dilution allocation factor for release pathway p. AFn may be assigned any value between 0 and 1 for each active release pathway, under the condition that the sum of the AFp for all active release pathways for the entire plant site does not exceed 1.Fd = the assured minimum dilution flow for the unit, in gpm.In the normal case in which the only release pathways with detectable radioactivity are the LIQUID RADWASTE TREATMENT SYSTEMs of each unit, AFp for each unit may be assigned the value of 0.5 to permit releases from either unit to be made without regard to any releases from the other unit; if only one unit's LIQUID RADWASTE TREATMENT SYSTEM is releasing at a given time, its AFp may be increased proportionately. | |||
If more precise allocation factor values are desired, they may be determined based on the relative radiological impact of each active release pathway;this may be approximated by multiplying the RDF of each effluent stream by its respective planned release flowrate, and comparing these values. If only one simultaneous release is being made, its AFp may be assigned the value of 1, making Fdp equal to Fd.2-22 VER 29 VEGP ODCM For the case where RDF < 1, the planned release meets the limits of Section 2.1.2 without dilution, and could be released with any desired effluent flowrate and dilution flowrate. | |||
However, in order to maintain individual doses due to liquid effluent releases as low as is reasonably achievable, no releases with detectable radioactivity should be made if the assured dilution flowrate, Fd, is less than 12,000 gpm.Step 4: Determine the maximum allowable waste discharge flowrate.For the case where RDF > 1, the maximum permissible effluent discharge flowrate for this release pathway, fm.p (in gpm), is calculated as follows: Fd° (2.7)P (RDF- 1)For the case RDF _< 1, equation (2.7) is not valid. However, as discussed above, when RDF < 1, the release may be made at full discharge pump capacity; the radioactivity monitor setpoint must still be calculated in accordance with Step 5 below.NOTE 1: Discharge flowrates are actually limited by the discharge pump capacity.When the calculated maximum permissible release flowrate exceeds the pump capacity, the release may be made at full capacity. | |||
Discharge flowrates less than the pump capacity must be achieved by throttling if this is available; if throttling is not available, the release may not be made as planned.NOTE 2: If, at the time of the planned release, there is detectable radioactivity due to plant operations in the dilution stream, the diluting capacity of the dilution stream is diminished. (In addition, sampling and analysis of the other radioactive effluents affecting the dilution stream must be sufficient to ensure that the liquid effluent dose limits specified in the controls of Section 2.1.3 are not exceeded.) | |||
Under these conditions, equation (2.7)must be modified to account for the radioactivity present in the dilution stream prior to the introduction of the planned release: fp =(RDF- 1) r dF ,ECLJ(2.8) where: Cir the measured concentration of radionuclide i in release pathway r that is contributing to radioactivity in the dilution stream.fr = the effluent discharge flowrate of release pathway r.If the entire dilution stream contains detectable activity due to plant operations, whether or not its source is identified, fr = Fd, and Cir is the 2-23 VER 29 VEGP ODCM concentration in the total dilution system. This note does not apply: a) if the RDF of the planned release is _< 1; or b) if the release contributing radioactivity to the dilution stream has been accounted for by the assignment of an allocation factor.Step 5: Determine the maximum radioactivity monitor setpoint concentration. | |||
Based on the values determined in previous steps, the radioactivity monitor setpoint for the planned release is calculated to ensure that the limits of Section 2.1.2 will not be exceeded. | |||
Because the radioactivity monitor responds primarily to gamma radiation, the monitor setpoint cp for release pathway p (in [tCi/mL) is based on the concentration of gamma emitters in the waste stream, as follows: cP = AP Cg (2.9)where: Ap an adjustment factor which will allow the setpoint to be established in a practical manner to prevent spurious alarms while allowing a margin between measured concentrations and the limits of Section 2.1.2.Step 5.a. If the concentration of gamma emitters in the effluent to be released is sufficient that the high alarm setpoint can be established at a level that will prevent spurious alarms, Ap should be calculated as follows: 1 Ap = x ADF RDF (2.10)1- (F,1P + f,,P)RDF Alp where: ADF = the assured dilution factor.fap the anticipated actual discharge flowrate for the planned release (in gpm), a value less than fmp.The release must then be controlled so that the actual effluent discharge flowrate does not exceed fap at any time.Step 5.b. Alternatively, Ap may be calculated as follows: ADF- RDF,,n AP =RDFy (2.11)2-24 VER 29 VEGP ODCM Step 5.c. Evaluate the computed value of Ap as follows: If Ap > 1, calculate the monitor setpoint, cp. However, if cp is within about 10 percent of Cg, it may be impractical to use this value of cp.This situation indicates that measured concentrations are approaching values which would cause limits of Section 2.1.2 to be exceeded. | |||
Therefore, steps should be taken to reduce potential concentrations at the point of discharge; these steps may include decreasing the planned effluent discharge flowrate, increasing the dilution stream flowrate, postponing simultaneous releases, and/or decreasing the effluent concentrations by further processing the liquid planned for release. Alternatively, allocation factors for the active liquid release pathways may be reassigned. | |||
When one or more of these actions has been taken, repeat Steps 1-5 to calculate a new radioactivity monitor setpoint.If Ap < 1, the release may not be made as planned. Consider the alternatives discussed in the paragraph above, and calculate a new setpoint based on the results of the actions taken.2.3.2.3 Use of the Calculated Setpoint The setpoint calculated above is in the units jtCi/mL. The monitor actually measures a count rate, subtracts a predetermined background count rate, and multiplies by a calibration factor to convert from count rate to [tCi/mL.Initial calibration of the monitors by the manufacturer and Georgia Power Company utilized NIST-traceable liquid solutions with gamma ray emissions over the range 0.08 to 1.33 MeV, in the exact geometry of each production monitor. The calibration factor is a function of the radionuclide mix in the liquid to be released, and will be calculated for the monitor based on the results of the pre-release sample results from the laboratory gamma-ray spectrometer system. The mix-dependent calibration factor will be used as the gain factor in the PERMS monitor, or used to modify the calculated base monitor setpoint so that the default calibration factor in the PERMS monitor can be left unchanged. | |||
Notwithstanding the initial calibration, monitor calibration data for conversion between count rate and concentration may include operational data obtained from determining the monitor response to stream concentrations measured by liquid sample analysis. | |||
In all cases, monitor background must be controlled so that the monitor is capable of responding to concentrations in the range of the setpoint value.2-25 VER 29 VEGP ODCM 2.3.3 Setpoints for Monitors on Normally Low-Radioactivity Streams Radioactivity in these streams (listed in Table 2-4 above) is expected to be at very low levels, generally below detection limits. Accordingly, the purpose of these monitors is to alarm upon the occurrence of significant radioactivity in these streams, and to terminate or divert the release where this is possible.2.3.3.1 Normal Conditions When radioactivity in one of these streams is at its normal low level, its radioactivity monitor setpoint should be established as close to background as practical to prevent spurious alarms, and yet alarm should an inadvertent release occur.2.3.3.2 Conditions Requiring an Elevated Setpoint Under the following conditions, radionuclide concentrations must be determined and an elevated radioactivity monitor setpoint determined for these pathways: For streams that can be diverted or isolated, a new monitor setpoint must be established when it is desired to discharge the stream directly to the dilution water even though the radioactivity in the stream exceeds the level which would normally be diverted or isolated.* For streams that cannot be diverted or isolated, a new monitor setpoint must be established whenever: | |||
the radioactivity in the stream becomes detectable above the background levels of the applicable laboratory analyses; or the associated radioactivity monitor detects activity in the stream at levels above the established alarm setpoint.When an elevated monitor setpoint is required for any of these effluent streams, it should be determined in the same manner as described in Section 2.3.2. However, special consideration must be given to Step 3. An allocation factor must be assigned to the normally low-radioactivity release pathway under consideration, and allocation factors for other release pathways discharging simultaneously must be adjusted downward (if necessary) to ensure that the sum of the allocation factors does not exceed 1. Sampling and analysis of the normally low-radioactivity streams must be sufficient to ensure that the liquid effluent dose limits specified in the controls of Section 2.1.3 are not exceeded.2-26 VER 29 VEGP ODCM 2.4 LIQUID EFFLUENT DOSE CALCULATIONS The following sub-sections present the methods required for liquid effluent dose calculations, in deepening levels of detail. Applicable site-specific pathways and parameter values for the calculation of De, A 1 j, and CFiv are summarized in Table 2-5.2.4.1 Calculation of Dose The dose limits for a MEMBER OF THE PUBLIC specified in Section 2.1.3 are on a per-unit basis. Therefore, the doses calculated in accordance with this section must be determined and recorded on a per-unit basis, including apportionment of releases shared between the two units.For the purpose of implementing Section 2.1.3, the dose to the maximum exposed individual due to radionuclides identified in liquid effluents released from each unit to UNRESTRICTED AREAS will be calculated as follows (equation from Reference 1, page 15): D,=Z rI ('At, CiF,) (2.12)where: D, = the cumulative dose commitment to the total body or to any organ T, in mrem, due to radioactivity in liquid effluents released during the total of the m time periods At,.Aj, = the site-related adult ingestion dose commitment factor, for the total body or for any organ T, due to identified radionuclide i, in (mrem.mL)/(h.plCi). | |||
Methods for the calculation of A, are presented below in Section 2.4.2.The values of Aj, to be used in dose calculations for releases from the plant site are listed in Table 2-8.At, = the length of time period I, over which C,/ and F, are averaged for liquid releases, in h.Ci, = the average concentration of radionuclide i in undiluted liquid effluent during time period I, in [tCi/mL. Only radionuclides identified and detected above background in their respective samples should be included in the calculation. | |||
F, = the near-field average dilution factor in the receiving water of the UNRESTRICTED AREA: 2-27 VER 29 VEGP ODCM F, f (2.13)F, xZ where: ft = the average undiluted liquid waste flowrate actually observed during the period of radioactivity release, in gpm.Ft = the average dilution stream flowrate actually observed during the period of radioactivity release, in gpm. If simultaneous releases from both units occur, the dilution stream flowrate Ft must be allocated between them. In such cases, F, is unit-specific. | |||
Z = the applicable dilution factor for the receiving water body, in the near field of the discharge structure, during the period of radioactivity release, from Table 2-5.NOTE: In equation (2.13), the product (Ft x Z) is limited to 1000 cfs (= 448,000 gpm) or less. (Reference 1, Section 4.3.)2.4.2 Calculation of A, The site-related adult ingestion dose commitment factor, Aij, is calculated as follows (equation adapted from Reference 1, page 16, by addition of the irrigated garden vegetation pathway): ,= 1. 14x 1' U+fBFi e-,'s + U,,CF., DF., (2.14)where: 1.14 x 10 5 = a units conversion factor, determined by: 106 pCi/pCi x 10 3 mL/L + 8760 h/y.U= the adult drinking water consumption rate applicable to the plant site (L/y).Dw= the dilution factor from the near field of the discharge structure for the plant site to the potable water intake location.= the decay constant for radionuclide i (h-1). Values of ki used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.tw= the transit time from release to receptor for potable water 2-28 VER 29 VEGP ODCM consumption (h).Uf = the adult rate of fish consumption applicable to the plant site (kg/y).BFj = the bioaccumulation factor for radionuclide i applicable to freshwater fish in the receiving water body for the plant site, in (pCi/kg)/(pCi/L) | |||
= (L/kg). For specific values applicable to the plant site, see Table 2-6.tf = the transit time from release to receptor for fish consumption (h).U= the adult consumption rate for irrigated garden vegetation applicable to the plant site (kg/y).CFiv = the concentration factor for radionuclide i in irrigated garden vegetation, as applicable to the vicinity of the plant site, in (pCi/kg)/(pCi/L). | |||
Methods for calculation of CFiv are presented below in Section 2.4.3.DFi, = the dose conversion factor for radionuclide i for adults, in organ T (mrem/pCi). | |||
For specific values, see Table 2-7.2.4.3 Calculation of Cfiv The concentration factor for radionuclide i in irrigated garden vegetation, CFiv in (L/kg), is calculated as follows: For radionuclides other than tritium (equation adapted from Reference 3, equations A-8 and A-9): iv=M fJ (2.15)For tritium (equation adapted from Reference 3, equations A-9 and A-10): CFjv = M. L, (2.16)where: M = the additional river dilution factor from the near field of the discharge structure for the plant site to the point of irrigation water usage.= the average irrigation rate during the growing season (L)/(m 2.h).r = the fraction of irrigation-deposited activity retained on the edible portions 2-29 VER 29 VEGP ODCM of leafy garden vegetation. | |||
Y, = the areal density (agricultural productivity) of leafy garden vegetation (kg/Mr 2)f, = the fraction of the year that garden vegetation is irrigated. | |||
B 1 v = the crop to soil concentration factor applicable to radionuclide i (pCi/kg garden vegetation)/(pCi/kg soil).P = the effective surface density of soil (kg/m 2).ki = the decay constant for radionuclide i (h-1). Values of k, used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.Xw = the rate constant for removal of activity from plant leaves by weathering (h-1).XEi = the effective removal rate for activity deposited on crop leaves (h-1)calculated as: XEi = Xi + Xw.te = the period of leafy garden vegetation exposure during the growing season (h).tb = the period of long-term buildup of activity in soil (h).th = the time between harvest of garden vegetation and human consumption (h).Lv = the water content of leafy garden vegetation edible parts (Llkg).2-30 VER 29 VEGP ODCM Table 2-5.Parameters for Calculation of Doses Due to Liquid Effluent Releases Dose Calculation Receptor Locations: | |||
Fish: Vicinity of plant discharge Drinking Water: 112 miles downstream, at Beaufort, SC (Reference 12)Irrigated Garden Vegetation: | |||
None (Reference 12)Numerical Parameters: | |||
Parameter Value Reference Z Uw Dw tw Uf tf Uv M I r Yv f, P xw t.tb th L, 10, for May through December 20, for January through April 730 L/y 8 48 h 21 kg/y 24 h 0 kg/y 1.0+No value 0.25 2.0 kg/m 2 1.0+240 kg/m 2 0.0021 h-1 (i.e., half-life of 14 d)1440 h (= 60 d)1.31 x 10 5 h (= 15 y)24 h 0.92 L/kg Ref. 11 Ref 3 Ref. 7 Ref. 3, Sec. A.2; Ref. 8 Ref. 3, Table E-5 Ref. 3, Sec. A.2 Ref. 12 Ref. 3, Table E-15.Ref. 3, Table E-1 5 Ref. 3, Table E-15 Ref. 3, Table E-15 Ref. 3, Table E-15 Ref. 3, Table E-15 Ref. 3, Table E-15 Based on Ref. 21, Table 5.16 (for lettuce, cabbage, etc.)* -Because there is no irrigated garden vegetation pathway downstream of the plant site, the consumption of irrigated garden vegetation is set to zero, and the other pathway parameters are defaults.+ -There is no established default value for this parameter. | |||
The most conservative physically realistic value is 1.0.2-31 VER 29 VEGP ODCM Table 2-6.Element Transfer Factors Freshwater Fish Element BFj*H 9.0 E-01 C 4.6 E+03 Na 1.0 E+02 P 3.0 E+03 Cr 2.0 E+02 Mn 4.0 E+02 Fe 1.0 E+02 Co 5.0 E+01 Ni 1.0 E+02 Cu 5.0 E+01 Zn 2.0 E+03 Br 4.2 E+02 Rb 2.0 E+03 Sr 3.0 E+01 Y 2.5 E+01 Zr 3.3 E+00 Nb 5.5 E+02 Mo 1.0 E+01 Tc 1.5 E+01 Ru 1.0 E+01 Rh 1.0 E+01 Ag 2.3 E+00 Sb 2.0 E+02 Te 4.0 E+02 I 1.5 E+01 Cs 2.0 E+03 Ba 4.0 E+00 La 2.5 E+01 Ce 1.0 E+00 Pr 2.5 E+01 Nd 2.5 E+01 W 1.2 E+03 Np 1.0 E+01 Bioaccumulation Factors for freshwater fish, in (pCi/kg)/(pCi/L). | |||
They are obtained from Reference 3 (Table A-I), except as follows: Reference 9 for P; Reference 2 (Table A-8)for Ag; and Reference 10 for Nb and Sb.2-32 VER 29 VEGP ODCM Table 2-7. Adult Ingestion Dose Factors Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 No Data 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 C-14 2.84E-06 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 Na-24 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 P-32 1.93E-04 1.20E-05 7.46E-06 No Data No Data No Data 2.17E-05 Cr-51 No Data No Data 2.66E-09 1.59E-09 5.86E-10 3.53E-09 6.69E-07 Mn-54 No Data 4.57E-06 8.72E-07 No Data 1.36E-06 No Data 1.40E-05 Mn-56 No Data 1.15E-07 2.04E-08 No Data 1.46E-07 No Data 3.67E-06 Fe-55 2.75E-06 1.90E-06 4.43E-07 No Data No Data 1.06E-06 1.09E-06 Fe-59 4.34E-06 1.02E-05 3.91E-06 No Data No Data 2.85E-06 3.40E-05 Co-58 No Data 7.45E-07 1.67E-06 No Data No Data No Data 1.51E-05 Co-60 No Data 2.14E-06 4.72E-06 No Data No Data No Data 4.02E-05 Ni-63 1.30E-04 9.01E-06 4.36E-06 No Data No Data No Data 1.88E-06 Ni-65 5.28E-07 6.86E-08 3.13E-08 No Data No Data No Data 1.74E-06 Cu-64 No Data 8.33E-08 3.91E-08 No Data 2.1OE-07 No Data 7.1OE-06 Zn-65 4.84E-06 1.54E-05 6.96E-06 No Data 1.03E-05 No Data 9.70E-06 Zn-69 1.03E-08 1.97E-08 1.37E-09 No Data 1.28E-08 No Data 2.96E-09 Br-83 No Data No Data 4.02E-08 No Data No Data No Data 5.79E-08 Br-84 No Data No Data 5.21E-08 No Data No Data No Data 4.09E-13 Br-85 No Data No Data 2.14E-09 No Data No Data No Data No Data Rb-86 No Data 2.11E-05 9.83E-06 No Data No Data No Data 4.16E-06 Rb-88 No Data 6.05E-08 3.21E-08 No Data No Data No Data 8.36E-19 Rb-89 No Data 4.01E-08 2.82E-08 No Data No Data No Data 2.33E-21 Sr-89 3.08E-04 No Data 8.84E-06 No Data No Data No Data 4.94E-05 Sr-90 7.58E-03 No Data 1.86E-03 No Data No Data No Data 2.19E-04 Sr-91 5.67E-06 No Data 2.29E-07 No Data No Data No Data 2.70E-05 All values are in (mrem/pCi ingested). | |||
They are obtained from Reference 3 (Table E-1 1), except as follows: Reference 2 (Table A-3) for Rh-105, Sb-124, and Sb-125.2-33 VER 29 VEGP ODCM Table 2-7 (contd). Adult Ingestion Dose Factors Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 2.15E-06 No Data 9.30E-08 No Data No Data No Data 4.26E-05 Y-90 9.62E-09 No Data 2.58E-10 No Data No Data No Data 1.02E-04 Y-91m 9.09E-11 No Data 3.52E-12 No Data No Data No Data 2.67E-10 Y-91 1.41E-07 No Data 3.77E-09 No Data No Data No Data 7.76E-05 Y-92 8.45E-10 No Data 2.47E-11 No Data No Data No Data 1.48E-05 Y-93 2.68E-09 No Data 7.40E-1 1 No Data No Data No Data 8.50E-05 Zr-95 3.04E-08 9.75E-09 6.60E-09 No Data 1.53E-08 No Data 3.09E-05 Zr-97 1.68E-09 3.39E-10 1.55E-10 No Data 5.12E-10 No Data 1.05E-04 Nb-95 6.22E-09 3.46E-09 1.86E-09 No Data 3.42E-09 No Data 2.1OE-05 Mo-99 No Data 4.31E-06 8.20E-07 No Data 9.76E-06 No Data 9.99E-06 Tc-99m 2.47E-10 6.98E-10 8.89E-09 No Data 1.06E-08 3.42E-10 4.13E-07 Tc-101 2.54E-10 3.66E-10 3.59E-09 No Data 6.59E-09 1.87E-10 1.1OE-21 Ru-103 1.85E-07 No Data 7.97E-08 No Data 7.06E-07 No Data 2.16E-05 Ru-105 1.54E-08 No Data 6.08E-09 No Data 1.99E-07 No Data 9.42E-06 Ru-106 2.75E-06 No Data 3.48E-07 No Data 5.31 E-06 No Data 1.78E-04 Rh-105 1.22E-07 8.86E-08 5.83E-08 No Data 3.76E-07 No Data 1.41 E-05 Ag-110m 1.60E-07 1.48E-07 8.79E-08 No Data 2.91 E-07 No Data 6.04E-05 Sb-124 2.81E-06 5.30E-08 1.11E-06 6.79E-09 No Data 2.18E-06 7.95E-05 Sb-125 2.23E-06 2.40E-08 4.48E-07 1.98E-09 No Data 2.33E-04 1.97E-05 Te-125m 2.68E-06 9.71E-07 3.59E-07 8.06E-07 1.09E-05 No Data 1.07E-05 Te-127m 6.77E-06 2.42E-06 8.25E-07 1.73E-06 2.75E-05 No Data 2.27E-05 Te-127 1.1OE-07 3.95E-08 2.38E-08 8.15E-08 4.48E-07 No Data 8.68E-06 Te-129m 1.15E-05 4.29E-06 1.82E-06 3.95E-06 4.80E-05 No Data 5.79E-05 Te-129 3.14E-08 1.18E-08 7.65E-09 2.41E-08 1.32E-07 No Data 2.37E-08 Te-131m 1.73E-06 8.46E-07 7.05E-07 1.34E-06 8.57E-06 No Data 8.40E-05 Te-131 1.97E-08 8.23E-09 6.22E-09 1.62E-08 8.63E-08 No Data 2.79E-09 2-34 VER 29 VEGP ODCM Table 2-7 (contd). Adult Ingestion Dose Factors Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 2.52E-06 1.63E-06 1.53E-06 1.80E-06 1.57E-05 No Data 7.71E-05 1-130 7.56E-07 2.23E-06 8.80E-07 1.89E-04 3.48E-06 No Data 1.92E-06 1-131 4.16E-06 5.95E-06 3.41E-06 1.95E-03 1.02E-05 No Data 1.57E-06 1-132 2.03E-07 5.43E-07 1.90E-07 1.90E-05 8.65E-07 No Data 1.02E-07 1-133 1.42E-06 2.47E-06 7.53E-07 3.63E-04 4.31E-06 No Data 2.22E-06 1-134 1.06E-07 2.88E-07 1.03E-07 4.99E-06 4.58E-07 No Data 2.51E-10 1-135 4.43E-07 1.16E-06 4.28E-07 7.65E-05 1.86E-06 No Data 1.31E-06 Cs-134 6.22E-05 1.48E-04 1.21E-04 No Data 4.79E-05 1.59E-05 2.59E-06 Cs-136 6.51E-06 2.57E-05 1.85E-05 No Data 1.43E-05 1.96E-06 2.92E-06 Cs-137 7.97E-05 1.09E-04 7.14E-05 No Data 3.70E-05 1.23E-05 2.11E-06 Cs-138 5.52E-08 1.09E-07 5.40E-08 No Data 8.01E-08 7.91E-09 4.65E-13 Ba-139 9.70E-08 6.91E-11 2.84E-09 No Data 6.46E-11 3.92E-11 1.72E-07 Ba-140 2.03E-05 2.55E-08 1.33E-06 No Data 8.67E-09 1.46E-08 4.18E-05 Ba-141 4.71E-08 3.56E-11 1.59E-09 No Data 3.31E-11 2.02E-11 2.22E-17 Ba-142 2.13E-08 2.19E-11 1.34E-09 No Data 1.85E-11 1.24E-11 3.OOE-26 La-140 2.50E-09 1.26E-09 3.33E-10 No Data No Data No Data 9.25E-05 La-142 1.28E-10 5.82E-11 1.45E-11 No Data No Data No Data 4.25E-07 Ce-141 9.36E-09 6.33E-09 7.18E-10 No Data 2.94E-09 No Data 2.42E-05 Ce-143 1.65E-09 1.22E-06 1.35E-10 No Data 5.37E-10 No Data 4.56E-05 Ce-144 4.88E-07 2.04E-07 2.62E-08 No Data 1.21E-07 No Data 1.65E-04 Pr-143 9.20E-09 3.69E-09 4.56E-10 No Data 2.13E-09 No Data 4.03E-05 Pr-144 3.01E-11 1.25E-11 1.53E-12 No Data 7.05E-12 No Data 4.33E-18 Nd-147 6.29E-09 7.27E-09 4.35E-10 No Data 4.25E-09 No Data 3.49E-05 W-187 1.03E-07 8.61E-08 3.01E-08 No Data No Data No Data 2.82E-05 Np-239 1.19E-09 1.17E-10 6.45E-11 No Data 3.65E-10 No Data 2.40E-05 2-35 VER 29 VEGP ODCM Table 2-8. Site-Related Ingestion Dose Factors, A 1.Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 0.00 1.32E+00 1.32E+00 1.32E+00 1.32E+00 1.32E+00 1.32E+00 C-14 3.13E+04 6.26E+03 6.26E+03 6.26E+03 6.26E+03 6.26E+03 6.26E+03 Na-24 1.36E+02 1.36E+02 1.36E+02 1.36E+02 1.36E+02 1.36E+02 1.36E+02 P-32 1.32E+06 8.22E+04 5.11E+04 0.00 0.00 0.00 1.49E+05 Cr-51 0.00 0.00 1.27E+00 7.58E-01 2.79E-01 1.68E+00 3.19E+02 Mn-54 0.00 4.41E+03 8.42E+02 0.00 1.31E+03 0.00 1.35E+04 Mn-56 0.00 1.74E-01 3.08E-02 0.00 2.21E-01 0.00 5.55E+00 Fe-55 6.86E+02 4.74E+02 1.11E+02 0.00 0.00 2.65E+02 2.72E+02 Fe-59 1.07E+03 2.51E+03 9.61E+02 0.00 0.00 7.01E+02 8.36E+03 Co-58 0.00 9.59E+01 2.15E+02 0.00 0.00 0.00 1.94E+03 Co-60 0.00 2.78E+02 6.14E+02 0.00 0.00 0.00 5.23E+03 Ni-63 3.25E+04 2.25E+03 1.09E+03 0.00 0.00 0.00 4.70E+02 Ni-65 1.72E-01 2.23E-02 1.02E-02 0.00 0.00 0.00 5.66E-01 Cu-64 0.00 2.75E+00 1.29E+00 0.00 6.94E+00 0.00 2.35E+02 Zn-65 2.32E+04, 7.37E+04 3.33E+04 0.00 4.93E+04 0.00 4.64E+04 Zn-69 7.88E-07 1.51E-06 1.05E-07 0.00 9.79E-07 0.00 2.26E-07 Br-83 0.00 0.00 3.83E-02 0.00 0.00 0.00 5.52E-02 Br-84 0.00 0.00 1.22E-12 0.00 0.00 0.00 9.61E-18 Br-85 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Rb-86 0.00 9.75E+04 4.54E+04 0.00 0.00 0.00 1.92E+04 Rb-88 0.00 1.29E-22 6.82E-23 0.00 0.00 0.00 1.78E-33 Rb-89 0.00 1.61E-26 1.14E-26 0.00 0.00 0.00 0.00 Sr-89 2.49E+04 0.00 7.16E+02 0.00 0.00 0.00 4.OOE+03 Sr-90 6.23E+05 0.00 1.53E+05 0.00 0.00 0.00 1.80E+04 Sr-91 7.25E+01 0.00 2.93E+00 0.00 0.00 0.00 3.45E+02 Sr-92 3.33E-01 0.00 1.44E-02 0.00 0.00 0.00 6.60E+00 Y-90 5.04E-01 0.00 1.35E-02 0.00 0.00 0.00 5.34E+03 Y-91m 1.04E-11 0.00 4.01E-13 0.00 0.00 0.00 3.04E-11 Y-91 9.77E+00 0.00 2.61E-01 0.00 0.00 0.00 5.38E+03 Y-92 4.61E-04 0.00 1.35E-05 0.00 0.00 0.00 8.07E+00 Y-93 3.19E-02 0.00 8.82E-04 0.00 0.00 0.00 1.01E+03 Zr-95 5.47E-01 1.75E-01 1.19E-01 0.00 2.75E-01 0.00 5.56E+02 Zr-97 7.40E-03, 1.49E-03 6.83E-04 0.00 2.26E-03 0.00 4.62E+02 Nb-95 8.09E+00 4.50E+00 2.42E+00 0.00 4.45E+00 0.00 2.73E+04 Mo-99 0.00 1.07E+02 2.04E+01 0.00 2.43E+02 0.00 2.49E+02 Tc-99m 5.70E-04 1.61E-03 2.05E-02 0.00 2.44E-02 7.89E-04 9.53E-01 All values are in (mrem.mL)/(h.[tCi). | |||
They are calculated using equation (2.14), and data from Table 2-5, Table 2-6, and Table 2-7. When "No Data" is shown for a radionuclide-organ combination in Table 2-7, A 1 , factors in this table are presented as zero.2-36 VER 29 VEGP ODCM Table 2-8 (contd). Site-Related Ingestion Dose Factors, Aj, Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Tc-101 2.71E-33 3.91E-33 3.83E-32 0.00 7.03E-32 2.00E-33 0.00 Ru-103 6.21E+00 0.00 2.68E+00 0.00 2.37E+01 0.00 7.25E+02 Ru-105 8.79E-03 0.00 3.47E-03 0.00 1.14E-01 0.00 5.38E+00 Ru-106 9.42E+01 0.00 1.19E+01 0.00 1.82E+02 0.00 6.1OE+03 Rh-105 2.32E+00 1.69E+00 1.11E+00 0.00 7.15E+00 0.00 2.68E+02 Ag-110m 2.53E+00 2.34E+00 1.39E+00 0.00 4.61E+00 0.00 9.56E+02 Sb-124 1.36E+03 2.56E+01 5.37E+02 3.28E+00 0.00 1.05E+03 3.84E+04 Sb-125 1.09E+03 1.17E+01 2.19E+02 9.68E-01 0.00 1.14E+05 9.63E+03 Te-125m 2.56E+03 9.29E+02 3.43E+02 7.71E+02 1.04E+04 0.00 1.02E+04 Te-127m 6.51E+03 2.33E+03 7.93E+02 1.66E+03 2.64E+04 0.00 2.18E+04 Te-127 1.78E+01 6.40E+00 3.85E+00 1.32E+01 7.25E+01 0.00 1.41E+03 Te-129m 1.09E+04 4.07E+03 1.73E+03 3.74E+03 4.55E+04 0.00 5.49E+04 Te-129 1.78E-05 6.68E-06 4.33E-06 1.36E-05 7.47E-05 0.00 1.34E-05 Te-131m 9.57E+02 4.68E+02 3.90E+02 7.42E+02 4.74E+03 0.00 4.65E+04 Te-131 8.64E-17 3.61E-17 2.73E-17 7.10E-17 3.78E-16 0.00 1.22E-17 Te-132 1.97E+03 1.27E+03 1.19E+03 1.41E+03 1.23E+04 0.00 6.02E+04 1-130 7.60E+00 2.24E+01 8.85E+00 1.90E+03 3.50E+01 0.00 1.93E+01 1-131 1.73E+02 2.48E+02 1.42E+02 8.13E+04 4.25E+02 0.00 6.55E+01 1-132 5.27E-03 1.41E-02 4.93E-03 4.93E-01 2.24E-02 0.00 2.65E-03 1-133 2.59E+01 4.51E+01 1.37E+01 6.62E+03 7.86E+01 0.00 4.05E+01 1-134 2.18E-08 5.94E-08 2.12E-08 1.03E-06 9.44E-08 0.00 5.17E-11 1-135 1.31E+00 3.44E+00 1.27E+00 2.27E+02 5.52E+00 0.00 3.89E+00 Cs-134 2.98E+05 7.1OE+05 5.80E+05 0.00 2.30E+05 7.62E+04 1.24E+04 Cs-136 2.96E+04 1.17E+05 8.42E+04 0.00 6.51E+04 8.92E+03 1.33E+04 Cs-137 3.82E+05 5.23E+05 3.43E+05 0.00 1.78E+05 5.90E+04 1.01E+04 Cs-138 9.12E-12 1.80E-11 8.92E-12 0.00 1.32E-11 1.31E-12 7.68E-17 Ba-139 5.64E-06 4.02E-09 1.65E-07 0.00 3.76E-09 2.28E-09 1.00E-05 Ba-140 3.74E+02 4.69E-01 2.45E+01 0.00 1.60E-01 2.69E-01 7.69E+02 Ba-141 8.47E-25 6.40E-28 2.86E-26 0.00 5.95E-28 3.63E-28 3.99E-34 Ba-142 0.00 0.00 0.00 0.00 0.00 0.00 0.00 La-140 1.10E-01 5.56E-02 1.47E-02 0.00 0.00 0.00 4.08E+03 La-142 2.19E-07 9.96E-08 2.48E-08 0.00 0.00 0.00 7.27E-04 Ce-141 1.15E-01 7.79E-02 8.84E-03 0.00 3.62E-02 0.00 2.98E+02 Ce-143 8.65E-03 6.39E+00 7.08E-04 0.00 2.81E-03 0.00 2.39E+02 Ce-144 6.22E+00 2.60E+00 3.34E-01 0.00 1.54E+00 0.00 2.1OE+03 Pr-143 6.10E-01 2.44E-01 3.02E-02 0.00 1.41E-01 0.00 2.67E+03 Pr-144 1.48E-28 6.14E-29 7.51E-30 0.00 3.46E-29 0.00 2.13E-35 Nd-147 4.11E-01 4.75E-01 2.84E-02 0.00 2.78E-01 0.00 2.28E+03 W-187 1.47E+02 1.23E+02 4.31E+01 0.00 0.00 0.00 4.04E+04 Np-239 2.81E-02 2.76E-03 1.52E-03 0.00 8.62E-03 0.00 5.67E+02 2-37 VER 29 VEGP ODCM 2.5 LIQUID EFFLUENT DOSE PROJECTIONS 2.5.1 Thirty-One Day Dose Projections In order to meet the requirements for operation of the LIQUID RADWASTE TREATMENT SYSTEM (see Section 2.1.4), dose projections must be made at least once each 31 days; this applies during periods in which a discharge to UNRESTRICTED AREAS of liquid effluents containing radioactive materials occurs or is expected.Projected 31-day doses to individuals due to liquid effluents may be determined as follows: Dpj x31+ D,, (2.17)where: D~p = the projected dose to the total body or organ r, for the next 31 days of liquid releases.Dec = the cumulative dose to the total body or organ c, for liquid releases that have occurred in the elapsed portion of the current quarter, plus the release under consideration. | |||
t = the number of whole or partial days elapsed into the current quarter, including the time to the end of the release under consideration (even if the release continues into the next quarter).Dia = the anticipated dose contribution to the total body or any organ ',, due to any planned activities during the next 31-day period, if those activities will result in liquid releases that are in addition to routine liquid effluents. | |||
If only routine liquid effluents are anticipated, Dta may be set to zero.2.5.2 Dose Projections for Specific Releases Dose projections may be performed for a particular release by performing a prerelease dose calculation assuming that the planned release will proceed as anticipated. | |||
For individual dose projections due to liquid releases, follow the methodology of Section 2.4, using sample analysis results for the source to be released, and parameter values expected to exist during the release period.2-38 VER 29 VEGP ODCM 2.6 DEFINITIONS OF LIQUID EFFLUENT TERMS The following symbolic terms are used in the presentation of liquid effluent calculations in the subsections above.Section of Term Definition Initial Use Ap= the adjustment factor used in calculating the effluent monitor setpoint for liquid release pathway p: the ratio of the assured dilution to the required dilution [unitless]. | |||
2.3.2.2 ADF = the assured dilution factor for a planned release [unitless]. | |||
2.3.2.2 AFp = the dilution allocation factor for liquid release pathway p 2.3.2.2[unitless]. | |||
A, = the site-related adult ingestion dose commitment factor, for the total body or for any organ T, due to identified radionuclide i [(mrem | |||
* mL)/(h * ýtCi)]. The values of Ai, are listed in Table 2-8. 2.4.1 Biv = the crop to soil concentration factor applicable to radionuclide i, [(pCi/kg garden vegetation)/(pCi/kg soil)]. 2.4.3 BFi = the bioaccumulation factor for radionuclide i for freshwater fish [(pCilkg)/(pCi/L)]. | |||
Values are listed in Table 2-6. 2.4.2 c = the setpoint of the radioactivity monitor measuring the concentration of radioactivity in the effluent line, prior to dilution and subsequent release [ptCi/mL]. | |||
2.3.2.1 Cp= the calculated effluent radioactivity monitor setpoint for liquid release pathway p [gCi/mL]. | |||
2.3.2.2 Ca -the gross concentration of alpha emitters in the liquid waste as measured in the applicable composite sample [giCi/mL]. | |||
2.3.2.2 CECL -the Effluent Concentration Limit stated in 10 CFR 20, Appendix B, Table 2, Column 2 [giCi/mL]. | |||
2.3.2.1 Cf= the concentration of Fe-55 in the liquid waste as measured in the applicable composite sample [gCi/mL]. | |||
2.3.2.2 2-39 VER 29 VEGP ODCM Section of Term Definition Initial Use Cg= the concentration of gamma emitter g in the liquid waste as measured by gamma ray spectroscopy performed on the applicable prerelease waste sample [pfCi/mL]. | |||
2.3.2.2 C = the measured concentration of radionuclide i in a sample of liquid effluent [VtCi/mL]. | |||
2.3.2.2 CQ = the average concentration of radionuclide i in undiluted liquid effluent during time period / [jiCi/mL]. | |||
2.4.1 Cir = the measured concentration of radionuclide i in release pathway r that is contributing to radioactivity in the dilution 2.3.2.2 stream [(,Ci/mL]. | |||
Cs = the concentration of strontium radioisotope s (Sr-89 or Sr-90) in the liquid waste as measured in the applicable composite sample [jiCi/mL]. | |||
2.3.2.2 Ct = the concentration of H-3 in the liquid waste as measured in the applicable composite sample [[tCi/mL]. | |||
2.3.2.2 CFi, = the concentration factor for radionuclide i in irrigated garden vegetation | |||
[(pCi/kg)/(pCi/L)]. | |||
2.4.2 Dw= the dilution factor from the near field of the discharge structure to the potable water intake location [unitless]. | |||
2.4.2 D = the cumulative dose commitment to the total body or to any organ c, due to radioactivity in liquid effluents released during a given time period [mrem]. 2.4.1 DOa = the anticipated dose contribution to the total body or any organ T, due to any planned activities during the next 31-day period [mrem]. 2.5.1 Dec = the cumulative dose to the total body or organ r, for liquid releases that have occurred in the elapsed portion of the current quarter, plus the release under consideration 2.5.1[mrem].2-40 VER 29 VEGP ODCM Term Definition D= the projected dose to the total body or organ c, for the next 31 days of liquid releases [mrem].DFi = the dose conversion factor for radionuclide i for adults, in organ t [mrem/pCi]. | |||
Values are listed in Table 2-7.ECL = the liquid Effluent Concentration Limit for radionuclide i from 10 CFR Part 20, Appendix B, Table 2, Column 2[gC i/m L.f = the effluent flowrate at the location of the radioactivity monitor [gpm].fap = the anticipated actual discharge flowrate for a planned release from liquid release pathway p [gpm].f= the fraction of the year that garden vegetation is irrigated | |||
[unitless]. | |||
fmp = the maximum permissible effluent discharge flowrate for release pathway p [gpm].fr = the effluent discharge flowrate of release pathway r [gpm].ft = the average undiluted liquid waste flowrate actually observed during the period of a liquid release [gpm].F = the dilution stream flowrate which can be assured prior to the release point to the UNRESTRICTED AREA [gpm].Fd = the entire assured dilution flowrate for the plant site during the release period [gpm].Fdp = the dilution flowrate allocated to release pathway p [gpm].F, = the near-field average dilution factor in the receiving water of the UNRESTRICTED AREA [unitless]. | |||
Ft = the average dilution stream flowrate actually observed during the period of a liquid release [gpm].I = the average irrigation rate during the growing season[L/(m 2.h)].Section of Initial Use 2.5.1 2.4.2 2.3.2.2 2.3.2.1 2.3.2.2 2.4.3 2.3.2.2 2.3.2.2 2.4.1 2.3.2.1 2.3.2.2 2.3.2.2 2.4.1 2.4.1 2.4.3 2-41 VER 29 VEGP ODCM Section of Term Definition Initial Use Lv = the water content of leafy garden vegetation edible parts 2.4.3[L/kg].M = the additional river dilution factor from the near field of the discharge structure for the plant site to the point of irrigation water usage [unitless]. | |||
2.4.3 P = the effective surface density of soil [kg/M 2]. 2.4.3 r = the fraction of irrigation-deposited activity retained on the edible portions of leafy garden vegetation. | |||
2.4.3 RDF = the required dilution factor: the minimum ratio by which liquid effluent must be diluted before reaching the UNRESTRICTED AREA, in order to ensure that the limits of Section 2.1.2 are not exceeded [unitless]. | |||
2.3.2.2 RDFy = the RDF for a liquid release due only to its concentration of gamma-emitting radionuclides | |||
[unitless]. | |||
2.3.2.2 RDFr = the RDF for a liquid release due only to its concentration of non-gamma-emitting radionuclides | |||
[unitless]. | |||
2.3.2.2 SF = the safety factor selected to compensate for statistical fluctuations and errors of measurement | |||
[unitless]. | |||
2.3.2.2 t = the number of whole or partial days elapsed into the current quarter, including the time to the end of the release under consideration. | |||
2.5.1 tb = the period of long-term buildup of activity in soil [h]. 2.4.3 te = the period of leafy garden vegetation exposure during the growing season [h]. 2.4.3 tf = the transit time from release to receptor for fish 2.4.2 consumption | |||
[h].th = the time between harvest of garden vegetation and human consumption | |||
[h]. 2.4.3 tw= the transit time from release to receptor for potable water consumption | |||
[h]. 2.4.2 2-42 VER 29 VEGP ODCM Section of Term Definition Initial Use TF = the tolerance factor selected to allow flexibility in the establishment of a practical monitor setpoint which could accommodate effluent releases at concentrations higher than the ECL values stated in 10 CFR 20, Appendix B, Table 2, Column 2 [unitless]; | |||
the tolerance factor must not 2.3.2.1 exceed a value of 10.Uf = the adult rate of fish consumption | |||
[kg/y]. 2.4.2 Uv= the adult consumption rate for irrigated garden vegetation | |||
[kg/y]. 2.4.2 Uw= the adult drinking water consumption rate applicable to the plant site [L/y]. 2.4.2 YV = the areal density (agricultural productivity) of leafy garden vegetation | |||
[kg/M 2]. 2.4.3 Z = the applicable dilution factor for the receiving water body, in the near field of the discharge structure, during the period of radioactivity release [unitless]. | |||
2.4.1 At 1 = the length of time period 1, over which Ci and F, are averaged for liquid releases [h]. 2.4.1 ,Ei = the effective removal rate for activity deposited on crop leaves [h-1]. 2.4.3= the decay constant for radionuclide i [h-1]. 2.4.2 k= the rate constant for removal of activity from plant leaves by weathering | |||
[h-1]. 2.4.3 2-43 VER 29 VEGP ODCM CHAPTER 3 GASEOUS EFFLUENTS 3.1 LIMITS OF OPERATION The following Limits of Operation implement requirements established by Technical Specifications Section 5.0. Terms printed in all capital letters are defined in Chapter 10.3.1.1 Gaseous Effluent Monitoring Instrumentation Control In accordance with Technical Specification 5.5.4.a, the radioactive gaseous effluent monitoring instrumentation channels shown in Table 3-1 shall be OPERABLE with their alarm/trip setpoints set to ensure that the limits of Section 3.1.2.a are not exceeded.The alarm/trip setpoints of these channels shall be determined in accordance with Section 3.3.3.1.1.1 Applicability These limits apply as shown in Table 3-1.3.1.1.2 Actions With a radioactive gaseous effluent monitoring instrumentation channel alarm/trip setpoint less conservative than required by the above control, immediately suspend the release of radioactive gaseous effluents monitored by the affected channel, declare the channel inoperable, or restore the setpoint to a value that will ensure that the limits of Section 3.1.2.a are met.With less than the minimum number of radioactive gaseous effluent monitoring instrumentation channels OPERABLE, take the ACTION shown in Table 3-1. Restore the inoperable instrumentation to operable status within 30 days, or if unsuccessful, explain in the next Radioactive Effluent Release Report, per Technical Specification 5.6.3, why this inoperability was not corrected in a timely manner.This control does not affect shutdown requirements or MODE changes.3.1.1.3 Surveillance Requirements Each radioactive gaseous effluent monitoring instrumentation channel shall be demonstrated OPERABLE by performance of the CHANNEL CHECK, SOURCE CHECK, CHANNEL CALIBRATION and CHANNEL OPERATIONAL TEST operations at the frequencies shown in Table 3-2.3-1 VER 29 VEGP ODCM 3.1.1.4 Basis The radioactive gaseous effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in gaseous effluents during actual or potential releases of gaseous effluents. | |||
The Alarm/Trip Setpoints for these instruments shall be calculated and adjusted in accordance with the methodology and parameters in Section 3.3 to ensure that the alarm/trip will occur prior to exceeding the limits of Section 3.1.2.a. The OPERABILITY and use of this instrumentation is consistent with the requirements of General Design Criteria 60, 63, and 64 of Appendix A to 10 CFR Part 50.3-2 VER 29 VEGP ODCM Table 3-1. Radioactive Gaseous Effluent Monitoring Instrumentation OPERABILITY Requirements Minimum Instrument Channels OPERABLE Applicability ACTION 1. GASEOUS RADWASTE TREATMENT SYSTEM (Common)a. Noble Gas Activity Monitor, with Alarm and Automatic Termination of Release (ARE-0014) 1 During releases' 45 b. Effluent System Flowrate Measuring Device (AFT-0014) 1 During releasesa 46 2. Turbine Building Vent (Each Unit)a. Noble Gas Activity Monitor (RE-1 2839C) 1 During releasesa 4a b. Iodine and Particulate Samplers (RE-12839A | |||
& B) 1 During releases' 51 c. Flowrate Monitor (FT-1 2839 or FIS-1 2 8 6 2)b 1 During releasesa 46 d. Sampler Flowrate Monitor (1FI-13211, 2FIT-13211) 1 During releasesa 46 3. Plant Vent (Each Unit)a. Noble Gas Activity Monitor (RE-1 2442C or RE-1 2444C) 1 At all times 47,48 b. Iodine Sampler/Monitor (RE-12442B or RE-12444B) 1 At all times 51 c. Particulate Sampler/Monitor (RE-1 2442A or RE-12444A) 1 At all times 51 d. Flowrate Monitor (FT-12442 or 12835) 1 At all times 46 e. Sampler Flowrate Monitor (FI-12442 or FI-12444) 1 At all times 46 4. Radwaste Processing Facility Vent (Common)a. Particulate Monitor (ARE-1 6980) 1 1 During releasesa 51 a. "During releases" means "During radioactive releases via this pathway." b. During emergency filtration. | |||
3-3 VER 29 VEGP ODCM Table 3-1 (contd). Notation for Table 3-1 -ACTION Statements ACTION 45 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, the contents of the tank(s) may be released to the environment for up to 14 days provided that prior to initiating the release: a. The local radiation monitor reading (if functional) is recorded at least once per 12 hours or at least two independent samples of the tank's contents are analyzed, and b. At least two technically qualified members of the Facility Staff independently verify the discharge line valving, and verify the release rate calculations. | |||
Otherwise, suspend release of radioactive effluents via this pathway.ACTION 46 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway may continue provided the flowrate is estimated at least once per 4 hours.ACTION 47 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway may continue provided the local radiation monitor reading (if functional) is recorded at least once per 12 hours or grab samples are taken at least once per 12 hours and these samples are analyzed for radioactivity within 24 hours. With the plant vent radiation monitor iodine and particulate channels inoperable during the loss of sample line heat tracing, the noble gas channel of RE-1 2442 and RE-12444 would still be considered valid.ACTION 48 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, record the local radiation monitor reading (if functional) for RE-2565C at least once per 12 hours or immediately suspend containment purging of radioactive effluents via this pathway.ACTION 49 -(Not Used)ACTION 50 -(Not Used)ACTION 51 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via the affected pathway may continue provided one of the following options is available (1) the 3-4 VER 29 VEGP ODCM local radiation monitor reading (if functional) is recorded at least once per 12 hours (2) samples are continuously collected with the installed skid or (3)samples are continuously collected with auxiliary sampling equipment. | |||
RE-12444A and B may be verified functional by recording local radiation monitor skid flow once per 12 hours. With the plant vent radiation monitor particulate and iodine channels inoperable during the loss of sample line heat tracing, estimate radioactive releases for up to 48 hours while continuing to monitor noble gas activity from RE-1 2442 and RE-1 2444.3-5 VER 29 VEGP ODCM Table 3-2. Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements Surveillance Requirements CHANNEL Instrument CHANNEL OPERA-CHANNEL SOURCE CALIBRA- TIONAL CHECK CHECK TION TEST MODESc 1. GASEOUS RADWASTE TREATMENT SYSTEM (Common)a. Noble Gas Activity Monitor, with Alarm and Automatic Termination of Release During (ARE-0014) | |||
P P Rb Ra(') Release b. Effluent System Flowrate Measuring Device During (AFT-0014) | |||
P NA R NA Release 2. Turbine Building Vent (Each Unit)a. Noble Gas Activity Monitor During (RE-12839C) | |||
D M Rb Ra(2) Release b. Iodine and Particulate During Samplers (RE-12839A&B) | |||
Wd NA NA NA Release c. Flowrate Monitor During (FT-12839 or FIS-12862) | |||
D NA R NA Release d. Sampler Flowrate Monitor During (1FI-13211, 2FIT-13211) | |||
D NA R Q Release 3. Plant Vent (Each Unit)a. Noble Gas Activity Monitor (RE-1 2442C or RE-12444C) | |||
D M Rb Ra(2) All b. Particulate and Iodine Monitors (RE-12442A&B) | |||
Wd NA R Ra(2) All c. Particulate and Iodine Samplers (RE-12444A&B) | |||
'Nd NA NA NA All d. Flowrate Monitor (FT-12442 or 12835) D NA R NA All e. Sampler Flowrate Monitor (FI-12442 or Fl-12444) | |||
D NA R Q All 4. Radwaste Processing Facility Vent (Common)a. Particulate Monitor Wd Q Re N/A During (ARE-16980) | |||
Release 3-6 VER 29 VEGP ODCM Table 3-2 (contd). Notation for Table 3-2 a. In addition to the basic functions of a CHANNEL OPERATIONAL TEST (Section 10.2): (1) The CHANNEL OPERATIONAL TEST shall also demonstrate that automatic isolation of this pathway and control room annunciation occurs (for item a. below only); and control room CRT indication occurs (if any of the following conditions exist): (a) Instrument indicates measured levels above the alarm/trip setpoint;(b) Instrument indicates an "Equipment Trouble" alarm;(c) Instrument indicates a "Low" alarm; or (d) Instrument indicates channel "Deactivated." (2) The CHANNEL OPERATIONAL TEST shall also demonstrate that control room annunciation occurs (for item a. below only); and that control room CRT indication occurs (if any of the following conditions exist): (a) Instrument indicates measured levels above the alarm/trip setpoint;(b) Instrument indicates an "Equipment Trouble" alarm;(c) Instrument indicates a "Low" alarm; or (d) Instrument indicates channel "Deactivated." ("Loss of counts" for ARE-16980 only)b. The initial CHANNEL CALIBRATION shall be performed using one or more of the reference standards certified by the National Institute of Standards and Technology, or using standards that have been obtained from suppliers that participate in measurement assurance activities with NIST. These standards shall permit calibrating the system over its intended range of energy and measurement range. For any subsequent CHANNEL CALIBRATION, sources that have been related to the initial calibration shall be used.c. MODES in which surveillance is required. "All" means "At all times." "During release" means "During radioactive release via this pathway." 3-7 VER 29 VEGP ODCM d. The channel check shall consist of visually verifying that the collection device (i.e., particulate filter or charcoal cartridge, etc.) is in place for sampling.e. The CHANNEL CALIBRATION verifies proper operation of the CHANNEL OPERATIONAL TEST requirements described in Notation a(2) above.3-8 VER 29 VEGP ODCM 3.1.2 Gaseous Effluent Dose Rate Control In accordance with Technical Specifications 5.5.4.c and 5.5.4.g, the licensee shall conduct operations so that the dose rates due to radioactive materials released in gaseous effluents from the site to areas at and beyond the SITE BOUNDARY are limited as follows: a. For noble gases: Less than or equal to a dose rate of 500 mrem/y to the total body and less than or equal to a dose rate of 3000 mrem/y to the skin, and b. For Iodine-1 31, Iodine-1 33, tritium, and for all radionuclides in particulate form with half-lives greater than 8 days: Less than or equal to a dose rate of 1500 mrem/y to any organ.3.1.2.1 Applicability This limit applies at all times.3.1.2.2 Actions With a dose rate due to radioactive material released in gaseous effluents exceeding the limit stated in Section 3.1.2, immediately decrease the release rate to within the stated limit.These limits do not affect shutdown requirements or MODE changes.3.1.2.3 Surveillance Requirements The dose rates due to radioactive materials in areas at or beyond the SITE BOUNDARY due to releases of gaseous effluents shall be determined to be within the above limits, in accordance with the methods and procedures in Section 3.4.1, by obtaining representative samples and performing analyses in accordance with the sampling and analysis program specified in Table 3-3.3.1.2.4 Basis This control is provided to ensure that gaseous effluent dose rates will be maintained within the limits that historically have provided reasonable assurance that radioactive material discharged in gaseous effluents will not result in a dose to a MEMBER OF THE PUBLIC in an UNRESTRICTED AREA, either within or outside the SITE BOUNDARY, exceeding the limits specified in Appendix I of 10 CFR Part 50, while allowing operational flexibility for effluent releases. | |||
For MEMBERS OF THE PUBLIC who may at times be within the SITE BOUNDARY, the occupancy of the MEMBER OF THE PUBLIC will be sufficiently low to compensate for any increase in the atmospheric diffusion factor above that for the SITE BOUNDARY.3-9 VER 29 VEGP ODCM The dose rate limit for Iodine-1 31, Iodine-1 33, tritium, and radionuclides in particulate form with half-lives greater than 8 days specifically applies to dose rates to a child via the inhalation pathway.This control applies to the release of gaseous effluents from all reactors at the site.3-10 VER 29 VEGP ODCM Table 3-3. Radioactive Gaseous Waste Sampling and Analysis Program Sampling and Analysis Requirementsa MINIMUM DETECTABLE Minimum CONCENTRA-Gaseous Sampling Analysis Type of Activity TION (MDC)Release Type FREQUENCY FREQUENCY Analysis (jtCi/mL)Waste Gas P P Noble Gas 1 E-4 Decay Tank Each Tank Grab Each Tank PRINCIPAL (Common) Sample GAMMA EMITTERS pi Noble Gas 1 E-4 Containment pC Each Furge PRINCIPAL Purge 14, Each Purge GAMMA EMITTERS 24" or14 (Each Unit) Grab Sample M H-3 (Oxide) 1 E-6 Noble Gas 1 E-4 Plant Vent Mc'd'f MC PRINCIPAL (Each Unit) Grab Sample GAMMA EMITTERS H-3 (Oxide) 1 E-6 Condenser Air Noble Gas 1 E-4 PRINCIPAL Ejector & MGAMMA EMITTERS Steam Packing Mple M Exhaust Grab Sample (Each Unit)b H-3 (Oxide) 1 E-6 we Charcoal 1-131 1 E-12 CONTINUOUS 8 or Silver Zeolite Sample We Particulate 1 E-11 CONTINUOUS Particulate PRINCIPAL Sample GAMMA EMITTERS Plant Vent, M Gross Alpha 1 E-1 1 Condenser Air COMPOSITE Ejector & Particulate Steam Packing CONTINUOUS 8 arile Exhaust (Each Sample Unit)b Q Sr-89, Sr-90 1 E-1 1 CONTINUOUS 8 COMPOSITE Particulate Sample Radwaste Wh Particulate 1 E-11 Processing Particulate PRINCIPAL Facility Vent CONTINUOUS 8 Sample GAMMA EMITTERS (Common)3-11 VER 29 VEGP ODCM Table 3-3 (contd). Notation for Table 3-3 a. Terms printed in all capital letters are defined in Chapter 10.b. The turbine building vent is the release point for the condenser air ejector and steam packing exhaust. All sampling and analyses may be omitted for this vent, provided the absence of a primary to secondary leak has been demonstrated, that is, if the gamma activity in the secondary water does not exceed background by more than 20%.c. Sampling and analysis shall also be performed following shutdown, startup, or a THERMAL POWER change exceeding 15% of the RATED THERMAL POWER within a one-hour period. This requirement does not apply if (1) analysis shows that the DOSE EQUIVALENT 1-131 concentration in the primary coolant has not increased more than a factor of 3; and (2) the noble gas monitor shows that effluent activity has not increased more than a factor of 3.d. Tritium grab samples shall be taken at least once per 24 hours when the refueling cavity is flooded.e. Samples shall be changed at least once per 7 days and analyses shall be completed within 48 hours after changing (or after removal from sampler).Sampling shall also be performed at least once per 24 hours for at least 7 days following each shutdown, startup, or THERMAL POWER change exceeding 15%of RATED THERMAL POWER in one hour, and analyses shall be completed within 48 hours of changing. | |||
When samples collected for 24 hours are analyzed, the corresponding MDC may be increased by a factor of 10. This requirement does not apply if (1) analysis shows that the DOSE EQUIVALENT 1-131 concentration in the primary coolant has not increased more than a factor of 3;and (2) the noble gas monitor shows that effluent activity has not increased more than a factor of 3.f. Tritium grab samples shall be taken at least once per 7 days from the Unit 1 plant vent, whenever spent fuel is in the spent fuel pool (Unit 1 plant vent only).g. The ratio of the sample flowrate to the sampled stream flowrate shall be known for the time period covered by each dose or dose rate calculation made in accordance with controls specified in Sections 3.1.2, 3.1.3, and 3.1.4.h. Samples shall be changed at least once per 7 days and analyses shall be completed within 48 hours after changing (or removal of sampler).3-12 VER 29 VEGP ODCM 3-13 VER 29 VEGP ODCM 3.1.3 Gaseous Effluent Air Dose Control In accordance with Technical Specifications 5.5.4.e and 5.5.4.h, the air dose due to noble gases released in gaseous effluents, from each reactor unit, to areas at and beyond the SITE BOUNDARY shall be limited to the following: | |||
: a. During any calendar quarter: Less than or equal to 5 mrad for gamma radiation and less than or equal to 10 mrad for beta radiation, and b. During any calendar year: Less than or equal to 10 mrad for gamma radiation and less than or equal to 20 mrad for beta radiation. | |||
3.1.3.1 Applicability This limit applies at all times.3.1.3.2 Actions With the calculated air dose from radioactive noble gases in gaseous effluents exceeding any of the above limits, prepare and submit to the Nuclear Regulatory Commission within 30 days a special report which identifies the cause(s) for exceeding the limit(s); | |||
defines the corrective actions that have been taken to reduce the releases;and defines the proposed corrective actions to be taken to assure that subsequent releases of radioactive noble gases in gaseous effluents will be in compliance with the limits of Section 3.1.3.This control does not affect shutdown requirements or MODE changes.3.1.3.3 Surveillance Requirements Cumulative air dose contributions from noble gas radionuclides released in gaseous effluents from each unit to areas at and beyond the SITE BOUNDARY, for the current calendar quarter and current calendar year, shall be determined in accordance with Section 3.4.2 at least once per 31 days.3.1.3.4 Basis This control is provided to implement the requirements of Sections 1I.B, III.A and IV.A of Appendix I, 10 CFR Part 50. Section 3.1.3 implements the guides set forth in Section ll.B of Appendix I. The ACTION statements in Section 3.1.3.2 provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I, assuring that the releases of radioactive material in gaseous effluents to UNRESTRICTED AREAS will be kept "as low as is reasonably achievable." The Surveillance requirements in Section 3.1.3.3 implement the requirements in Section III.A of Appendix I, which require that conformance with the guides of Appendix I be shown 3-14 VER 29 VEGP ODCM by calculational procedures based on models and data such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated. | |||
The dose calculations established in Section 3.4.2 for calculating the doses due to the actual releases of noble gases in gaseous effluents are consistent with the methodology provided in Regulatory Guide 1.109 (Reference 3), and Regulatory Guide 1.111 (Reference 5). The equations in Section 3.4.2 provided for determining the air doses at the SITE BOUNDARY are based upon the historical annual average atmospheric conditions. | |||
====3.1.4 Control==== | |||
on Gaseous Effluent Dose to a Member of the Public In accordance with Technical Specifications 5.5.4.e and 5.5.4.i, the dose to a MEMBER OF THE PUBLIC from 1-131, 1-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents released, from each reactor unit, to areas at and beyond the SITE BOUNDARY shall be limited to the following: | |||
: a. During any calendar quarter: Less than or equal to 7.5 mrem to any organ, and b. During any calendar year: Less than or equal to 15 mrem to any organ.3.1.4.1 Applicability This limit applies at all times.3.1.4.2 Actions With the calculated dose from the release of 1-131, 1-133, tritium, or radionuclides in particulate form with half-lives greater than 8 days, in gaseous effluents exceeding any of the above limits, prepare and submit to the Nuclear Regulatory Commission within 30 days a special report which identifies the cause(s) for exceeding the limit; defines the corrective actions that have been taken to reduce the releases of radioiodines and radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents; and defines proposed corrective actions to assure that subsequent releases will be in compliance with the limits stated in Section 3.1.4.This control does not affect shutdown requirements or MODE changes.3.1.4.3 Surveillance Requirements Cumulative organ dose contributions to a MEMBER OF THE PUBLIC from 1-131, 1-133, tritium, and radionuclides in particulate form with half-lives greater than 8 days released in gaseous effluents from each unit to areas at and beyond the SITE BOUNDARY, for the current calendar quarter and current calendar year, shall be determined in accordance with Section 3.4.3 at least once per 31 days.3.1.4.4 Basis 3-15 VER 29 VEGP ODCM This control is provided to implement the requirements of Section II.C, III.A and IV.A of Appendix 1, 10 CFR Part 50. The limits stated in Section 3.1.4 are the guides set forth in Section II.C of Appendix I. The ACTION statements in Section 3.1.4.2 provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive materials in gaseous effluents to UNRESTRICTED AREAS will be kept "as low as is reasonably achievable." The calculational methods specified in the Surveillance Requirements of Section 3.1.4.3 implement the requirements in Section III.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data, such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated. | |||
The calculational methods in Section 3.4.3 for calculating the doses due to the actual releases of the subject materials are consistent with the methodology provided in Regulatory Guide 1.109 (Reference 3), and Regulatory Guide 1.111 (Reference 5).These equations provide for determining the actual doses based upon the historical annual average atmospheric conditions. | |||
The release specifications for radioiodines, radioactive materials in particulate form and radionuclides other than noble gases are dependent on the existing radionuclide pathways to man, in the areas at and beyond the SITE BOUNDARY. | |||
The pathways which were examined in the development of these calculations were: 1) individual inhalation of airborne radionuclides, 2) deposition of radionuclides onto green leafy garden vegetation with subsequent consumption by man, 3) deposition onto grassy areas where milk animals and meat producing animals graze with consumption of the milk and meat by man, and 4) deposition on the ground with subsequent exposure of man.3.1.5 Gaseous Radwaste Treatment System Control In accordance with Technical Specification 5.5.4.f, the GASEOUS WASTE PROCESSING SYSTEM and the VENTILATION EXHAUST TREATMENT SYSTEM shall be OPERABLE. | |||
The appropriate portions of the GASEOUS WASTE PROCESSING SYSTEM and the VENTILATION EXHAUST TREATMENT SYSTEM shall be used to reduce radioactive materials in gaseous wastes prior to their discharge when the projected doses in 31 days due to gaseous effluent releases, from each reactor unit, to areas at and beyond the SITE BOUNDARY would exceed 0.2 mrad to air from gamma radiation, 0.4 mrad to air from beta radiation, or 0.3 mrem to any organ of a MEMBER OF THE PUBLIC.3.1.5.1 Applicability These limits apply at all times.3.1.5.2 Actions 3-16 VER 29 VEGP ODCM With gaseous waste being discharged without treatment and in excess of the limits in Section 3.1.5, prepare and submit to the Nuclear Regulatory Commission within 30 days a special report which includes the following information: | |||
: a. Identification of any inoperable equipment or subsystem and the reason for inoperability, b. Action(s) taken to restore the inoperable equipment to OPERABLE status, and c. Summary description of action(s) taken to prevent a recurrence. | |||
This control does not affect shutdown requirements or MODE changes.3.1.5.3 Surveillance Requirements Doses due to gaseous releases from each unit to areas at and beyond the SITE BOUNDARY shall be projected at least once per 31 days, in accordance with Section 3.5.1, when the GASEOUS WASTE PROCESSING SYSTEM or the VENTILATION EXHAUST TREATMENT SYSTEM is not being fully utilized.The GASEOUS WASTE PROCESSING SYSTEM and the VENTILATION EXHAUST TREATMENT SYSTEM shall be demonstrated OPERABLE: by meeting the controls of Sections 3.1.2, and either 3.1.3 (for the GASEOUS WASTE PROCESSING SYSTEM) or 3.1.4 (for the VENTILATION EXHAUST TREATMENT SYSTEM).3.1.5.4 Basis The OPERABILITY of the GASEOUS WASTE PROCESSING SYSTEM ensures that the system will be available for use whenever gaseous effluents require treatment prior to release to the environment. | |||
The requirement that the appropriate portions of this system be used, when specified, provides reasonable assurance that the releases of radioactive materials in gaseous effluents will be kept "as low as is reasonably achievable." This control implements the requirements of 10 CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR Part 50, and the design objectives given in Section IL.D of Appendix I to 10 CFR Part 50. The specified limits governing the use of appropriate portions of the system were specified as a suitable fraction of the dose design objectives set forth in Section II.B and II.C of Appendix 1, 10 CFR Part 50, for gaseous effluents. | |||
This control applies to the release of radioactive materials in gaseous effluents from each unit at the site. For units with shared radwaste treatment systems, the gaseous effluents from the shared system are proportioned among the units sharing that system.3-17 VER 29 VEGP ODCM 3.1.6 Major Changes to Gaseous Radioactive Waste Treatment Systems Licensee initiated MAJOR CHANGES TO GASEOUS RADIOACTIVE WASTE TREATMENT SYSTEMS: a. Shall be reported to the Nuclear Regulatory Commission in the Radioactive Effluents Release Report for the period in which the change was implemented. | |||
The discussion of each change shall contain the information described in Section 7.2.2.7.b. Shall become effective upon review and approval by the Vice President | |||
-Plant.3-18 VER 29 VEGP ODCM 3.2 GASEOUS WASTE PROCESSING SYSTEM At Plant Vogtle, there are five potential points where radioactivity may be released to the atmosphere in gaseous discharges. | |||
These five potential release pathways are the Unit 1 and Unit 2 Plant Vents; the Unit 1 and Unit 2 Turbine Building Vents; and the Radwaste Processing Facility Vent. However, the Turbine Building Vents are not normal release pathways unless a primary-to-secondary leak exists. The Radwaste Processing Facility Vent is not a normal release pathway unless a spill occurs. The figures on the following pages give schematic diagrams of the Gaseous Waste Treatment System and the Ventilation Exhaust Treatment Systems (Reference 11).The Unit 1 Plant Vent release pathway includes two release sources that are common to the two units: ventilation air from the Fuel Handling Building, and discharges from the GASEOUS WASTE PROCESSING SYSTEM. Otherwise, discharges from the two reactor units are separated. | |||
Reactor Containment Building ventilation releases are through the respective plant vents. The Turbine Building Vent serves as the discharge point for both the condenser air ejector and the steam packing exhauster system. The Radwaste Processing Facility Vent includes sources from the Radwaste Processing Facility Process area.Releases from the two Turbine Building Vents and the Radwaste Processing Facility Vent are considered to be ground-level releases, whereas releases from the two Plant Vents are considered mixed-mode releases. | |||
Chapter 8 discusses the calculation of atmospheric dispersion parameters using the ground-level and mixed-mode (i.e., split-wake) models. All five potential release pathways are considered to be continuous (as opposed to batch) in nature.3-19 VER 29 VEGP ODCM Radioactivity Monitor ARE-0014 To Unit 1 Plant Vent via Auxiliary Building Ventilation System To Chemical Volume Control Tank To Waste Gas Decay Tank Header I I I I Unit 2 Waste Gas Volume Control Tank Purge Recycle Evaporator Vent Condenser Waste Evaporator Vent Condenser Recycle Holdup Tank Eductor Reactor Coolant Drain Tank*Dotted line operational between 20 and 100 psig NOTE: This is typical of both units. However, Unit 2 GWPS releases via Unit 1 plant vent.Figure 3-1.Schematic Diagram of the Gaseous Radwaste Treatment System 3-20 VER 29 VEGP ODCM Plant Vent Radioactivity Monitor I RE12442A,B,C HEARE 255,,C Fe HEanlg iT I I CF I CF I CF I I I HEPA /HEPAI HEPA Radioactivi R Ctor ty Monitor I I RE 0039A M Auxiliary | |||
)Building Radioactivity Monitor I RE2565A,B,C Fuel Handling ( ) ( )Building CF (Shared)*HC HetingCiReactor ME Moistur ElMinator t tr y Mthe FuContainment ARE-0014 From Waste Gas Processing Area and temSystem HEPA -High-Efficiency Particulate Air Filter CF -Activated Charcoal Filter HC -Heating Coil ME -Moisture Eliminator | |||
* Prior to treatment by the Fuel Handling Building Ventilation Exhaust Treatment System, Exhaust from Unit I Spent Fuel Pool Area is monitored by ARE2532B and ARE2533B; exhaust from Unit 2 Spent Fuel Pool Area is monitored by ARE2532A and ARE2533A.Figure 3-2. Schematic Diagram of the Unit 1 Plant Vent Release Pathway 3-21 VER 29 VEGP ODCM Plant Vent I 3-22 VER 29 VEGP ODCM 0 Radioactivity Monitor 2RE12442A,B,C Auxiliary Building Radioactivity Monitor Reactor Containment HEPA -High-Efficiency Particulate Air Filter CF -Activated Charcoal Filter HC -Heating Coil ME -Moisture Eliminator Figure 3-3. Schematic Diagram of the Unit 2 Plant Vent Release Pathway 3-23 VER 29 VEGP ODCM Turbine Building Radioactivity Monitor I(2)RE12839A,B,C NC Steam Jet Air Steam Packing HEPA -High-Efficiency Particulate Air Filter CF -Activated Charcoal Filter HC -Heating Coil DE -Demister NO -Normally Open NC -Normally Closed NOTE: This is typical of both units.Figure 3-4.Schematic Diagram of the Turbine Building Vent Release Pathway (Typical of Both Units)3-24 VER 29 VEGP ODCM Raciwaste Proc:cssing Facility Vent Radioaclivity Monitor ARE 16980 IIEPA Radwastc PJOcclsiDs Facility Proee:u Area-Room 101 Figure 3-5. Schematic Diagram of the Radwaste Processing Facility Ventilation Release Pathway 3-25 VER 29 VEGP ODCM 3.3 GASEOUS EFFLUENT MONITOR SETPOINTS 3.3.1 General Provisions Regarding Noble Gas Monitor Setpoints Noble gas radioactivity monitor setpoints calculated in accordance with the methodology presented in this section are intended to ensure that the limits of Section 3.1.2.a are not exceeded. | |||
They will be regarded as upper bounds for the actual high alarm setpoints. | |||
That is, a lower high alarm setpoint may be established or retained on the monitor, if desired. Intermediate level setpoints should be established at an appropriate level to give sufficient warning prior to reaching the high alarm setpoint.If no release is planned for a given pathway, or if there is no detectable activity in the gaseous stream being evaluated for release, the setpoint should be calculated in accordance with the methods presented below, based on an assumed concentration of Kr-88 that leads to a practical setpoint. | |||
A practical setpoint in this context is one which prevents spurious alarms, and yet produces an alarm should a significant inadvertent release occur.Section 3.1.1 establishes the requirements for gaseous effluent monitoring instrumentation, and Section 3.2 describes the VENTILATION EXHAUST TREATMENT SYSTEM and the GASEOUS WASTE PROCESSING SYSTEM. From those Sections, it can be seen that certain monitors are located on final release pathways, that is, streams that are being monitored immediately before being discharged from the plant;the setpoint methodology for these monitors is presented in Section 3.3.2. Other monitors are located on source streams, that is, streams that merge with other streams prior to passing a final monitor and being discharged; the setpoint methodology for these monitors is presented in Section 3.3.3. Table 3-4 identifies which of these setpoint methodologies applies to each monitor. Some additional monitors with special setpoint requirements are discussed in Section 3.3.5.As established in Section 3.1.1, gaseous effluent monitor setpoints are required only for the noble gas monitors on certain potential release streams: the two Plant Vents, the two Turbine Building Vents, and the GASEOUS WASTE PROCESSING SYSTEM discharge. | |||
However, because of the potential significance of releases from other sources, Section 3.3 discusses setpoint methodologies for certain additional monitors, as well.3-20 VER 29 VEGP ODCM Table 3-4. Applicability of Gaseous Monitor Setpoint Methodologies Final Release Pathways with no Monitored Source Streams Setpoint Method: Release Elevation: | |||
Section 3.3.2 Ground-level Unit 1 or Unit 2 Turbine Building Vent Monitor: Maximum Flowrate: 1 RE-12839C/2RE-12839C 900 cfm (4.25 E+05 mL/s)Final Release Pathways with One or More Monitored Source Streams Release Elevation: | |||
Mixed-Mode Unit 1 Plant Vent Monitors: Maximum Flowrate: Setpoint Method: Release Type: 1 RE-12442C, 1 RE-12444C 187,000 cfm (8.83 E+07 mL/s)Section 3.3.2 CONTINUOUS Source Stream: Unit 1 Reactor Containment Puraqe Monitor: 1 RE-2565C Maximum Flowrate: | |||
release-dependent Setpoint Method: Section 3.3.3 Release Type: BATCH Source Stream: Gaseous Waste Treatment System Monitor: Maximum Flowrate: Setpoint Method: Release Type: Unit 2 Plant Vent Monitors: Maximum Flowrate: Setpoint Method: Release Type: ARE-0014 release-dependent Section 3.3.3 BATCH 2RE-12442C, 2RE-12444C 112,500 cfm (5.31 E+07 mL/s)Section 3.3.2 CONTINUOUS Source Stream: Unit 2 Reactor Containment Purge Monitor: Maximum Flowrate: Setpoint Method: Release Type: 2RE-2565C release-dependent Section 3.3.3 BATCH (X3-Q-vb Values for Use in Setpoint Calculations Ground-Level Releases: Mixed-Mode Releases: 2.55 x 10-6 s/m 3 [NE Sector]4.62 x 10-7 s/m 3[NE Sector]Maximum flowrate values are from Reference 11, Table 11.5.2-1 and Table 11.5.5-1.3-21 VER 29 VEGP ODCM 3.3.2 Setpoint for the Final Noble Gas Monitor on Each Release Pathway 3.3.2.1 Overview of Method Gaseous effluent radioactivity monitors are intended to alarm prior to exceeding the limits of Section 3.1.2.a. Therefore, their alarm setpoints are established to ensure compliance with the following equation: flAG. ~SF .X .Rt c =the lesser of AG. (3.1)LAG.SF.X.Rk where: c = the setpoint, in jtCi/mL, of the radioactivity monitor measuring the concentration of radioactivity in the effluent line prior to release. The setpoint represents a concentration which, if exceeded, could result in dose rates exceeding the limits of Section 3.1.2.a at or beyond the SITE BOUNDARY.AG = an administrative allocation factor applied to divide the release limit among all the gaseous release pathways at the site.SF = the safety factor selected to compensate for statistical fluctuations and errors of measurement. | |||
X = the noble gas concentration for the release under consideration. | |||
Rt = the ratio of the dose rate limit for the total body, 500 mrem/y, to the dose rate to the total body for the conditions of the release under consideration. | |||
Rk = the ratio of the dose rate limit for the skin, 3000 mrem/y, to the dose rate to the skin for the conditions of the release under consideration. | |||
Equation (3.1) shows the relationships of the critical parameters that determine the setpoint. | |||
However, in order to apply the methodology presented in the equation to a mixture of noble gas radionuclides, radionuclide-specific concentrations and dose factors must be taken into account under conditions of maximum flowrate for the release point and annual average meteorology. | |||
The basic setpoint method presented below is applicable to the radioactivity monitor nearest the point of release for the release pathway. For monitors measuring the radioactivity in source streams that merge with other streams prior to subsequent monitoring and release, the modifications presented in Section 3.3.3 must be applied.3-22 VER 29 VEGP ODCM 3.3.2.2 Setpoint Calculation Steps Step 1: Determine the concentration, Xjv, of each noble gas radionuclide i in the gaseous stream v being considered for release, in accordance with the sampling and analysis requirements of Section 3.1.2. Then sum these concentrations to determine the total noble gas concentration, YXjv.Step 2: Determine Rt, the ratio of the dose rate limit for the total body, 500 mrem/y, to the total body dose rate due to noble gases detected in the release under consideration, as follows: Rt= 500 (3.2)(7-)vb y K-Qv where: 500 = the dose rate limit for the total body, 500 mrem/y.FXIQ)vb = the highest annual average relative concentration at the SITE BOUNDARY for the discharge point of release pathway v. Table 3-4 includes an indication of what release elevation is applicable to each release pathway; release elevation determines the appropriate value of FxQ)Vb *Ki = the total-body dose factor due to gamma emissions from noble gas radionuclide i, in (mrem/y)/(p.Ci/m 3), from Table 3-5.Qiv = the release rate of noble gas radionuclide i from the release pathway under consideration, in [tCi/s, calculated as the product of Xiv and fav, where: Xi = the concentration of noble gas radionuclide i for the particular release, in p.Ci/mL.fav = the maximum anticipated flowrate for release pathway v during the period of the release under consideration, in mL/s.Step 3: Determine Rk, the ratio of the dose rate limit for the skin, 3000 mrem/y, to the skin dose rate due to noble gases detected in the release under consideration, as follows: 3000 (3.3)(X/Q-),h Y_ [(L' + 1. 1M).Q I 3-23 VER 29 VEGP ODCM where: 3000 = the dose rate limit for the skin, 3000 mrem/y.Li = the skin dose factor due to beta emissions from noble gas radionuclide i, in (mrem/y)/(ptCi/m3), from Table 3-5.= the air dose factor due to gamma emissions from noble gas radionuclide i, in (mrad/y)I(ý.Ci/m3), from Table 3-5.1.1 = the factor to convert air dose in mrad to skin dose in mrem.All other terms were defined previously. | |||
Step 4: Determine the maximum noble gas radioactivity monitor setpoint concentration. | |||
Based on the values determined in previous steps, the radioactivity monitor setpoint for the planned release is calculated to ensure that the limits of Section 3.1.2.a will not be exceeded. | |||
Because the radioactivity monitor responds primarily to radiation from noble gas radionuclides, the monitor setpoint Cnv (in [tCi/mL) is based on the concentration of all noble gases in the waste stream, as follows: where: Cnv = the calculated setpoint, in ý.Ci/mL, for the noble gas monitor serving gaseous release pathway v.SAG | |||
* SF" YX,, " R, c,,,,= the lesser of (3.4)LAG | |||
* SF.EXiV ARA i AGv = the administrative allocation factor for gaseous release pathway v, applied to divide the release limit among all the gaseous release pathways at the site. The allocation factor may be assigned any value between 0 and 1, under the condition that the sum of the allocation factors for all simultaneously-active final release pathways at the entire plant site does not exceed 1. Alternative methods for determination of AGv are presented in Section 3.3.4.SF = the safety factor selected to compensate for statistical fluctuations and errors of measurement. | |||
The value for the safety factor must be between 0 and 1. A value of 0.5 is reasonable for gaseous releases;a more precise value may be developed if desired.3-24 VER 29 VEGP ODCM Xiv = the measured concentration of noble gas radionuclide i in gaseous stream v, as defined in Step 1, in [tCi/mL.The values of Rt and Rk to be used in the calculation are those which were determined in Steps 2 and 3 above.Step 5: Determine whether the release is permissible, as follows: If Cnv Xiv, the release is permissible. | |||
However, if Cnv is within about 10 percent of YZXi,, it I may be impractical to use this value of Cnv. This situation indicates that measured concentrations are approaching values which would cause the limits of Section 3.1.2.a to be exceeded. | |||
Therefore, steps should be taken to reduce contributing source terms of gaseous radioactive material, or to adjust the allocation of the limits among the active release points. The setpoint calculations (steps 1-4) must then be repeated with parameters that reflect the modified conditions. | |||
If Cnv < Y-Xiv, the release may not be made as planned. Consider the alternatives discussed in the paragraph above, and calculate a new setpoint based on the results of the actions taken.3.3.2.3 Use of the Calculated Setpoint The setpoint calculated above is in the units p.Ci/mL. The monitor actually measures a count rate, subtracts a predetermined background count rate, and multiplies by a calibration factor to convert from count rate to 1 LCi/mL.Initial calibration by the manufacturer and Georgia Power Company of the gaseous effluent monitors specified in Section 3.1.1 utilized at least one NIST-traceable gaseous radionuclide source in the exact geometry of each production monitor. The point and gaseous sources used covered the beta particle end point energy range from 0.293 MeV to at least 1.488 MeV. The calibration factor is a function of the radionuclide mix in the gas to be released, and normally will be calculated for the monitor based on the results of the sample results from the laboratory gamma-ray spectrometer system. The mix-dependent calibration factor will be used as the gain factor in the PERMS monitor, or used to modify the calculated base monitor setpoint so that the default calibration factor in the PERMS monitor can be left unchanged. | |||
Notwithstanding the initial calibration, monitor calibration data for conversion between count rate and concentration may include operational data obtained from determining the monitor response to stream concentrations measured by sample analysis.3-25 VER 29 VEGP ODCM In all cases, monitor background must be controlled so that the monitor is capable of responding to concentrations in the range of the setpoint value. Contributions to the monitor background may include any or all of the following factors: ambient background radiation, plant-related radiation levels at the monitor location (which may change between shutdown and power conditions), and internal background due to contamination of the monitor's sample chamber.3.3.3 Setpoints for Noble Gas Monitors on Effluent Source Streams Table 3-4 lists certain gaseous release pathways as being source streams. As may be seen in the figures of Section 3.2, these are streams that merge with other streams, prior to passing a final radioactivity monitor and being released. | |||
Unlike the final monitors, the source stream monitors measure radioactivity in effluent streams for which flow can be terminated; therefore, the source stream monitors have control logic to terminate the source stream release at the alarm setpoint.3.3.3.1 Setpoint of the Monitor on the Source Stream Step 1: Determine the concentration XIs of each noble gas radionuclide i in source stream s (in 1.Ci/mL) according to the results of its required sample analyses [see Section 3.1.2].Step 2: Determine rt, the ratio of the dose rate limit for the total body, 500 mrem/y, to the total body dose rate due to noble gases detected in the source stream under consideration. | |||
Use the Xis values and the maximum anticipated source stream flowrate fas in equation (3.2) to determine the total body dose rate for the source stream, substituting rt for Rt.The SITE BOUNDARY relative dispersion value used in Steps 2 and 3 for the source stream is the same as the (X--Q)vb that applies to the respective merged stream. This is because the (xlQ) value is determined by the meteorology of the plant site and the physical attributes of the release point, and is unaffected by whether or not a given source stream is operating. | |||
Step 3: Determine rk, the ratio of the dose rate limit for the skin, 3000 mrem/y, to the skin dose rate due to noble gases detected in the source stream under consideration. | |||
Use the Xis values and the maximum anticipated source stream flow rate fas in equation (3.3) to determine the skin dose rate for the source stream, substituting rk for Rk.Step 4: Determine the maximum noble gas radioactivity monitor setpoint concentration, as follows: 3-26 VER 29 VEGP ODCM{AGs SF -Y Xis" rt Cns = the lesser of (3.5)AGs *SF .Xis.rk where: Cns = the calculated setpoint (in [tCi/mL) for the noble gas monitor serving gaseous source stream s.AGs = the administrative allocation factor applied to gaseous source stream s. For a given final release point v, the sum of all the AGs values for source streams contributing to the final release point must not exceed the release point's allocation factor Agv.Xis = the measured concentration of noble gas radionuclide i in gaseous source stream s, as defined in Step 1, in pCi/mL.The values of rt and rk to be used in the calculation are those which were determined in Steps 2 and 3 above. The safety factor, SF, was defined previously. | |||
Step 5: Determine whether the release is permissible, as follows: If Cns > ZXis, the release is permissible. | |||
However, if Cns is within about 10 percent of ZX 8 s, it may be impractical to use this value of Cns. This situation indicates that measured concentrations are approaching values which would cause the limits of Section 3.1.2.a to be exceeded. | |||
Therefore, steps should be taken to reduce contributing source terms of gaseous radioactive material, or to adjust the allocation of the limits among the active release points. The setpoint calculations (steps 1-4) must then be repeated with parameters that reflect the modified conditions. | |||
If Cns < EXis, the release may not be made as planned. Consider the alternatives discussed in the paragraph above, and calculate a new setpoint based on the results of the actions taken.3.3.3.2 Effect on the Setpoint of the Monitor on the Merged Stream Before beginning a release from a monitored source stream, a setpoint must be determined for the source stream monitor as presented in Section 3.3.3.1. In addition, whether or not the source stream has its own effluent monitor, the previously-determined maximum allowable setpoint for the downstream final monitor on the merged stream must be redetermined. | |||
This is accomplished by repeating the steps of Section 3.3.2, with the following modifications. | |||
3-27 VER 29 VEGP ODCM Modification 1: The new maximum anticipated flowrate of the merged stream is the sum of the old merged stream maximum flowrate, and the maximum flowrate of the source stream being considered for release.(Janew = (Li. l + fa, (3.6)Modification 2: The new concentration of noble gas radionuclide i in the merged stream includes both the contribution of the merged stream without the source stream, and the source stream being considered for release.tv ' _ (fa, )"/d,, .(X, )o,,, + fas* Xi ,.s -t iv nmew (Jav),ne, t -I 3.3.4 Determination of Allocation Factors, AG When simultaneous gaseous releases are conducted, an administrative allocation factor must be applied to divide the release limit among the active gaseous release pathways.This is to assure that the dose rate limit for areas at and beyond the SITE BOUNDARY (see Section 3.1.2) will not be exceeded by simultaneous releases. | |||
The allocation factor for any pathway may be assigned any value between 0 and 1, under the following two conditions: | |||
: 1. The sum of the allocation factors for all simultaneously-active final release paths at the plant site may not exceed 1.2. The sum of the allocation factors for all simultaneously-active source streams merging into a given final release pathway may not exceed the allocation factor of that final release pathway.Any of the following three methods may be used to assign the allocation factors to the active gaseous release pathways: 1. For ease of implementation, AG, may be equal for all release pathways: '1 AG, = -(3.8)where: N = the number of simultaneously active gaseous release pathways.2. AG, for a given release pathway may be selected based on an estimate of the portion of the total SITE BOUNDARY dose rate (from all simultaneous releases)that is contributed by the release pathway. During periods when a given building 3-28 VER 29 VEGP ODCM or release pathway is not subject to gaseous radioactive releases, it may be assigned an allocation factor of zero.3. AG, for a given release pathway may be selected based on a calculation of the portion of the total SITE BOUNDARY dose rate that is contributed by the release pathway, as follows: (XI/Qlb (K Q 1 N)AGv = N (3.9)where: (ROQ)vb = the annual average SITE BOUNDARY relative concentration applicable to the gaseous release pathway v for which the allocation factor is being determined, in s/m 3.Ki = the total-body dose factor due to gamma emissions from noble gas radionuclide i, in (mremly)I( jiCi/m 3), from Table 3-5.QiV = the release rate of noble gas radionuclide i from release pathway v, in ACi/s, calculated as the product of X 1 v and fav, where: Xiv = the concentration of noble gas radionuclide i applicable to the gaseous release pathway v for which the allocation factor is being determined, in ý.Ci/mL.fav = the discharge flowrate applicable to gaseous release pathway v for which the allocation factor is being determined, in mL/s.= the annual average SITE BOUNDARY relative concentration applicable to active gaseous release pathway r, in s/m 3.Qir = the release rate of noble gas radionuclide i applicable to active release pathway r, in ItCi/s, calculated as the product of Xir and far, where: Xir = the concentration of noble gas radionuclide i applicable to active gaseous release pathway r, in pICi/mL.far = the discharge flowrate applicable to active gaseous release pathway r, in mL/s.N = the number of simultaneously active gaseous release pathways (including pathway v that is of interest). | |||
3-29 VER 29 VEGP ODCM NOTE: Although equations (3.8) and (3.9) are written to illustrate the assignment of the allocation factors for final release pathways, they may also be used to assign allocation factors to the source streams that merge into a given final release pathway.3.3.5 Setpoints for Noble Gas Monitors with Special Requirements At present, VEGP has no noble gas monitors for which setpoint methodologies are to be presented in the ODCM, and that require methods other than those in Section 3.3.2 or Section 3.3.3.3.3.6 Setpoints for Particulate and Iodine Monitors In accordance with Section 5.1.1 of NRC NUREG-0133 (Reference 1), the effluent controls of Section 3.1.1 do not require that the ODCM establish setpoint calculation methods for particulate and iodine monitors. | |||
Therefore, the following is provided for information only: Initial setpoints for the particulate channels of effluent monitors RE-12442 and RE-2565 were determined as described in Reference 13.3-30 VER 29 VEGP ODCM 3.4 GASEOUS EFFLUENT COMPLIANCE CALCULATIONS 3.4.1 Dose Rates at and Beyond the Site Boundary Because the dose rate limits for areas at and beyond the SITE specified in Section 3.1.2 are site limits applicable at any instant in time, the summations extend over all simultaneously active gaseous final release pathways at the plant site. Table 3-4 identifies the gaseous final release pathways at the plant site, and indicates the (XlQ)Vb value for each.3.4.1.1 Dose Rates Due to Noble Gases For the purpose of implementing the controls of Section 3.1.2.a, the dose rates due to noble gas radionuclides in areas at or beyond the SITE BOUNDARY, due to releases of gaseous effluents, shall be calculated as follows: For total body dose rates: DRt =y_ý(XIQ)Vb, y[KjQij1 (3.10)For skin dose rates: where: DRt = the total body dose rate at the time of the release, in mrem/y.DRk = the skin dose rate at the time of the release, in mrem/y.Qiv = the release rate of noble gas radionuclide i, in ýtCi/s, equal to the product of ft, and Xv, where: fry = the actual average flowrate for release pathway v during the period of the release, in mL/s.All other terms were defined previously. | |||
3.4.1.2 Dose Rates Due to Iodine-1 31, Iodine-1 33, Tritium, and Radionuclides in Particulate Form with Half-Lives Greater than 8 Days For the purpose of implementing the controls of Section 3.1.2.b, the dose rates due to Iodine-1 31, Iodine-1 33, tritium, and all radionuclides in particulate form with half-lives greater than 8 days, in areas at or beyond the SITE BOUNDARY, due to releases of gaseous effluents, shall be calculated as follows: 3-31 VER 29 VEGP ODCM DRVk =(5Y_,b ZVO LY IP Q', i, (3.12)where: DRo = the dose rate to organ o at the time of the release, in mrem/y.Pio = the site-specific dose factor for radionuclide i and organ o, in (mrem/y)/(ýLCi/m 3). Since the dose rate limits specified in Section 3.1.2.b apply only to the child age group exposed to the inhalation pathway, the values of Pi,, may be obtained from Table 3-9, "Raipj for Inhalation Pathway, Child Age Group." Qqv = the release rate of radionuclide i from gaseous release pathway v, in pCi/s. For the purpose of implementing the controls of Section 3.1.2.b, only 1-131, 1-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days should be included in this calculation. | |||
All other terms were defined previously. | |||
====3.4.2 Noble==== | |||
Gas Air Dose at or Beyond Site Boundary For the purpose of implementing the controls of Section 3.1.3, air doses in areas at or beyond the SITE BOUNDARY due to releases of noble gases from each unit shall be calculated as follows (adapted from Reference 1, page 28, by including only long-term releases): | |||
D,6 = 3.17x 10 {Yiý2Qb Nj .iv (3.13)Dy =3.17x 10{X /Q),Vb [Mi , Qiv (3.14)where: 3.17 x 10-8 = a units conversion factor: 1 y/(3.15 x 10 7 s).Dý = the air dose due to beta emissions from noble gas radionuclides, in mrad.Dy = the air dose due to gamma emissions from noble gas radionuclides, in mrad.Ni = the air dose factor due to beta emissions from noble gas radionuclide i (mrad/y)/(jxCi/m 3), from Table 3-5.3-32 VER 29 VEGP ODCM Mi = the air dose factor due to gamma emissions from noble gas radionuclide i (mrad/y)I(ptCi/m 3), from Table 3-5.Oil = the cumulative release of noble gas radionuclide i from release pathway v (ýiCi), during the period of interest.and all other terms are as defined above.Because the air dose limit is on a per-reactor-unit basis, the summations extend over all gaseous final release pathways for a given unit. For a release pathway discharging materials originating in both reactor units, the activity discharged from the release point may be apportioned to the two units in any reasonable manner, provided that all activity released via the particular shared release pathway is apportioned to one or the other unit.The gaseous final release pathways at the plant site, and the --Q)vb for each, are identified in Table 3-4.3-33 VER 29 VEGP ODCM Table 3-5.Dose Factors for Exposure to a Semi-Infinite Cloud of Noble Gases y -Body (K) 13- Skin (L) 7- Air (M) 3 -Air (N)Nuclide (mrem/y) per (mrem/y) per (mrad/y) per (mrad/y) per (ýtCilm 3) (1 iCilm 3) (gCilm 3) ([LCi/m 3)Kr-83m 7.56 E-02 0.00 E+00 1.93 E+01 2.88 E+02 Kr-85m 1.17 E+03 1.46 E+03 1.23 E+03 1.97 E+03 Kr-85 1.61 E+01 1.34 E+03 1.72 E+01 1.95 E+03 Kr-87 5.92 E+03 9.73 E+03 6.17 E+03 1.03 E+04 Kr-88 1.47 E+04 2.37 E+03 1.52 E+04 2.93 E+03 Kr-89 1.66 E+04 1.01 E+04 1.73 E+04 1.06 E+04 Kr-90 1.56 E+04 7.29 E+03 1.63 E+04 7.83 E+03 Xe-131m 9.15 E+01 4.76 E+02 1.56 E+02 1.11 E+03 Xe-1 33m 2.51 E+02 9.94 E+02 3.27 E+02 1.48 E+03 Xe-133 2.94 E+02 3.06 E+02 3.53 E+02 1.05 E+03 Xe-1 35m 3.12 E+03 7.11 E+02 3.36 E+03 7.39 E+02 Xe-135 1.81 E+03 1.86 E+03 1.92 E+03 2.46 E+03 Xe-137 1.42 E+03 1.22 E+04 1.51 E+03 1.27 E+04 Xe-138 8.83 E+03 4.13 E+03 9.21 E+03 4.75 E+03 Ar-41 8.84 E+03 2.69 E+03 9.30 E+03 3.28 E+03 All values in this table were obtained from Reference 3 (Table B-i), with units converted. | |||
3-34 VER 29 VEGP ODCM Table 3-6.Dose Factors for Exposure to Direct Radiation from Noble Gases in an Elevated Finite Plume The contents of this table are not applicable to VEGP.3-35 VER 29 VEGP ODCM 3-36 VER 29 VEGP ODCM 3.4.3 Dose to a Member of the Public at or Beyond Site Boundary The dose received by an individual due to gaseous releases from each reactor unit, to areas at or beyond the SITE BOUNDARY, depends on the individual's location, age group, and exposure pathways. | |||
The MEMBER OF THE PUBLIC expected to receive the highest dose in the plant vicinity is referred to as the controlling receptor. | |||
The dosimetrically-significant attributes of the currently-defined controlling receptor are presented in Table 3-7.Doses to a MEMBER OF THE PUBLIC due to gaseous releases of 1-131,1-133, tritium, and all radionuclides in particulate form from each unit shall be calculated as follows (equation adapted from Reference 1, page 29, by considering only long-term releases): | |||
Dja = 3.17x 10-" Y{ZiE R [J-W,, [ QKip 1 (3.15)where: Dja = the dose to organ j of an individual in age group a, due to gaseous releases of 1-131, 1-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days, in mrem.3.17 x 10-8 = a units conversion factor: 1 y/(3.15 x 10 7 s).Raipj the site-specific dose factor for age group a, radionuclide i, exposure pathway p, and organ j. For the purpose of implementing the controls of Section 3.1.4, the exposure pathways applicable to calculating the dose to the currently-defined controlling receptor are included in Table 3-7; values of Raipj for each exposure pathway and radionuclide applicable to calculations of dose to the controlling receptor are included in Tables 3-8 through 3-12.A detailed discussion of the methods and parameters used for calculating Raipj for the plant site is presented in Chapter 9. That information may be used for recalculating the Raipj values if the underlying parameters change, or for calculating Raipm values for special radionuclides and age groups when performing the assessments discussed in Section 3.4.4 below.Wvi = the annual average relative dispersion or deposition at the location of the controlling receptor, for release pathway v, as appropriate to exposure pathway p and radionuclide i.3-37 VER 29 VEGP ODCM For all tritium pathways, and for the inhalation of any radionuclide: | |||
Wjp is (XIQ),, , the annual average relative dispersion factor for release pathway v, at the location of the controlling receptor (s/m 3).For the ground-plane exposure pathway, and for all ingestion-related pathways for radionuclides other than tritium: Wvip is FJIQ-)vP, the annual average relative deposition factor for release pathway v, at the location of the controlling receptor (m-2). Values of (x-Q)vp and (DI-Q-)vp for use in calculating the dose to the currently-defined controlling receptor are included in Table 3-7.'iv = the cumulative release of radionuclide i from release pathway v, during the period of interest (ptCi). For the purpose of implementing the controls of Section 3.1.4, only 1-131, 1-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days should be included in this calculation. | |||
In any dose assessment using the methods of this subsection, only radionuclides detectable above background in their respective samples should be included in the calculation. | |||
Because the member of the public dose limit is on a per-unit basis, the summations extend over all gaseous final release pathways for a given unit. For a release pathway discharging materials originating in both reactor units, the activity discharged from the release point may be apportioned between the two units in any reasonable manner, provided that all activity released from the plant site is apportioned to one or the other unit.The gaseous final release pathways at the plant site, and the release elevation for each, are identified in Table 3-4.3-38 VER29 3-38 VER 29 VEGP ODCM Table 3-7.Attributes of the Controlling Receptor The locations of members of the public in the vicinity of the plant site, and the exposure pathways associated with those locations, are determined in the Annual Land Use Census.Dispersion and deposition values were calculated based on site meteorological data collected for the period January 1, 1985 through December 31, 1987.Based on an analysis of this information, the current controlling receptor for the plant site is described as follows.Sector: Distance: Age Group: WSW 1.2 miles Child Exposure Pathways: | |||
Inhalation, ground plane, cow meat, and garden vegetation Dispersion Factors (-XIQvb: Ground-Level release points: Mixed-Mode release points: 6.20 E-7 s/m 3 1.27 E-7 s/m 3 Deposition Factors (DI-Qvb: Ground-Level release points: Mixed-Mode release points: 2.80 E-9 m 2 9.90 E-10 m-2 3-39 VER 29 VEGP ODCM 3-40 VER 29 VEGP ODCM 3.4.4 Dose Calculations to Support Other Requirements Case 1: A radiological impact assessment may be required to support evaluation of a reportable event.Dose calculations may be performed using the equations in Section 3.4.3, with the substitution of the dispersion and deposition parameters | |||
[(X/Q) and (D/Q)] for the period covered by the report, and using the appropriate pathway dose factors (Raipj) for the receptor of interest. | |||
Methods for calculating (X/Q) and (D/Q) from meteorological data are presented in Chapter 8.Values of Raipj other than those presented in Tables 3-8 through 3-12 may need to be calculated. | |||
Methods and parameters for calculating values of Raipj are presented in Chapter 9. When calculating Raipo for evaluation of an event, pathway and usage factors specific to the receptor involved in the event may be used in place of the values in Chapter 9, if the specific values are known.Case 2: A dose calculation is required to evaluate the results of the Land Use Census, under the provisions of Section 4.1.2.In the event that the Land Use Census reveals that exposure pathways have changed at previously-identified locations, or if new locations are identified, it may be necessary to calculate doses at two or more locations to determine which should be designated as the controlling receptor. | |||
Such dose calculations may be performed using the equations in Section 3.4.3, with the substitution of the annual average dispersion and deposition values [-j-Q-) and (D-I-Q)] for the locations of interest, and using the appropriate pathway dose factors (Raipj) for the receptors of interest.Methods for calculating (X/Q) and (D/Q) from meteorological data are presented in Chapter 8. The values of Raio other than those presented in Tables 3-8 through 3-12 may need to be calculated. | |||
Methods and parameters for calculating values of Raipj are presented in Chapter 9.Case 3: Under Section 5.2, a dose calculation may be required to support the determination of a component of the total dose to a receptor other than that currently defined as the controlling receptor.Dose calculations would be performed using the equations in Section 3.4.3, with the dispersion and deposition parameters and appropriate values of (Raipj) for the receptor of interest.Appropriate values of the dispersion and deposition parameters, if not found in Table 3-7, would need to be calculated. | |||
Methods for calculating (X/Q) and (D/Q)from meterological data are presented in Chapter 8.3-41 VER 29 VEGP ODCM Appropriate values of Raipj, if not found in Tables 3-8 through 3-12, would need to be calculated. | |||
Methods and parameters for calculating values of Raipj are presented in Chapter 9.3-42 VER 29 VEGP ODCM Table 3-8. Raipj for Ground Plane Pathway, All Age Groups Nuclide T. Body Skin H-3 0.00 0.00 C-14 0.00 0.00 P-32 0.00 0.00 Cr-51 4.66E+06 5.51 E+06 Mn-54 1.39E+09 1.63E+09 Fe-55 0.00 0.00 Fe-59 2.73E+08 3.21 E+08 Co-58 3.79E+08 4.44E+08 Co-60 2.15E+10 2.53E+10 Ni-63 0.00 0.00 Zn-65 7.47E+08 8.59E+08 Rb-86 8.99E+06 1.03E+07 Sr-89 2.16E+04 2.51E+04 Sr-90 0.00 0.00 Y-91 1.07E+06 1.21 E+06 Zr-95 2.45E+08 2.84E+08 Nb-95 1.37E+08 1.61 E+08 Ru-103 1.08E+08 1.26E+08 Ru-106 4.22E+08 5.07E+08 Ag-110m 3.44E+09 4.01E+09 Sb-124 5.98E+08 6.90E+08 Sb-125 2.34E+09 2.64E+09 Te-125m 1.55E+06 2.13E+06 Te-127m 9.16E+04 1.08E+05 Te-129m 1.98E+07 2.31E+07 1-131 1.72E+07 2.09E+07 1-133 2.45E+06 2.98E+06 Cs-134 6.86E+09 8.OOE+09 Cs-136 1.51E+08 1.71E+08 Cs-137 1.03E+10 1.20E+10 Ba-140 2.05E+07 2.35E+07 Ce-141 1.37E+07 1.54E+07 Ce-144 6.95E+07 8.04E+07 Pr-143 0.00 0.00 Nd-147 8.39E+06 1.01E+07 1. Units are m 2.(mremlyr)l([tCifs). | |||
: 2. The values in the Total Body column also apply to the Bone, Liver, Thyroid, Kidney, Lung, and GI-LLI organs.3. This table also supports the calculations of section 6.2.3-43 VER 29 VEGP ODCM Table 3-9. Raipj for Inhalation Pathway, Child Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 0.00 1.12E+03 1.12E+03 1.12E+03 1.12E+03 1.12E+03 1.12E+03 C-14 3.59E+04 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 P-32 2.60E+06 1.14E+05 9.88E+04 0.00 0.00 0.00 4.22E+04 Cr-51 0.00 0.00 1.54E+02 8.55E+01 2.43E+01 1.70E+04 1.08E+03 Mn-54 0.00 4.29E+04 9.51E+03 0.00 1.OOE+04 1.58E+06 2.29E+04 Fe-55 4.74E+04 2.52E+04 7.77E+03 0.00 0.00 1.11E+05 2.87E+03 Fe-59 2.07E+04 3.34E+04 1.67E+04 0.00 0.00 1.27E+06 7.07E+04 Co-58 0.00 1.77E+03 3.16E+03 0.00 0.00 1.11E+06 3.44E+04 Co-60 0.00 1.31E+04 2.26E+04 0.00 0.00 7.07E+06 9.62E+04 Ni-63 8.21E+05 4.63E+04 2.80E+04 0.00 0.00 2.75E+05 6.33E+03 Zn-65 4.26E+04 1.13E+05 7.03E+04 0.00 7.14E+04 9.95E+05 1.63E+04 Rb-86 0.00 1.98E+05 1.14E+05 0.00 0.00 0.00 7.99E+03 Sr-89 5.99E+05 0.00 1.72E+04 0.00 0.00 2.16E+06 1.67E+05 Sr-90 1.01E+08 0.00 6.44E+06 0.00 0.00 1.48E+07 3.43E+05 Y-91 9.14E+05 0.00 2.44E+04 0.00 0.00 2.63E+06 1.84E+05 Zr-95 1.90E+05 4.18E+04 3.70E+04 0.00 5.96E+04 2.23E+06 6.11E+04 Nb-95 2.35E+04 9.18E+03 6.55E+03 0.00 8.62E+03 6.14E+05 3.70E+04 Ru-103 2.79E+03 0.00 1.07E+03 0.00 7.03E+03 6.62E+05 4.48E+04 Ru-106 1.36E+05 0.00 1.69E+04 0.00 1.84E+05 1.43E+07 4.29E+05 Ag-110m 1.69E+04 1.14E+04 9.14E+03 0.00 2.12E+04 5.48E+06 1.OOE+05 Sb-124 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Sb-125 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Te-125m 6.73E+03 2.33E+03 9.14E+02 1.92E+03 0.00 4.77E+05 3.38E+04 Te-127m 2.49E+04 8.55E+03 3.02E+03 6.07E+03 6.36E+04 1.48E+06 7.14E+04 Te-129m 1.92E+04 6.85E+03 3.04E+03 6.33E+03 5.03E+04 1.76E+06 1.82E+05 1-131 4.81E+04 4.81E+04 2.73E+04 1.62E+07 7.88E+04 0.00 2.84E+03 1-133 1.66E+04 2.03E+04 7.70E+03 3.85E+06 3.38E+04 0.00 5.48E+03 Cs-134 6.51E+05 1.01E+06 2.25E+05 0.00 3.30E+05 1.21E+05 3.85E+03 Cs-136 6.51E+04 1.71E+05 1.16E+05 0.00 9.55E+04 1.45E+04 4.18E+03 Cs-137 9.07E+05 8.25E+05 1.28E+05 0.00 2.82E+05 1.04E+05 3.62E+03 Ba-140 7.40E+04 6.48E+01 4.33E+03 0.00 2.11E+01 1.74E+06 1.02E+05 Ce-141 3.92E+04 1.95E+04 2.90E+03 0.00 8.55E+03 5.44E+05 5.66E+04 Ce-144 6.77E+06 2.12E+06 3.61E+05 0.00 1.17E+06 1.20E+07 3.89E+05 Pr-143 1.85E+04 5.55E+03 9.14E+02 0.00 3.OOE+03 4.33E+05 9.73E+04 Nd-147 1.08E+04 8.73E+03 6.81E+02 0.00 4.81E+03 3.28E+05 8.21E+04 1.2.Units are (mremlyr)I(p Cilm 3) for all radionuclides. | |||
This table also supports the calculations of section 6.2.3-44 VER 29 VEGP ODCM Table 3-10.Raipj for Inhalation Pathway, Adult Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 0.00 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 C-14 1.82E+04 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 P-32 1.32E+06 7.71E+04 5.01E+04 0.00 0.00 0.00 8.64E+04 Cr-51 0.00 0.00 1.00E+02 5.95E+01 2.28E+01 1.44E+04 3.32E+03 Mn-54 0.00 3.96E+04 6.30E+03 0.00 9.84E+03 1.40E+06 7.74E+04 Fe-55 2.46E+04 1.70E+04 3.94E+03 0.00 0.00 7.21E+04 6.03E+03 Fe-59 1.18E+04 2.78E+04 1.06E+04 0.00 0.00 1.02E+06 1.88E+05 Co-58 0.00 1.58E+03 2.07E+03 0.00 0.00 9.28E+05 1.06E+05 Co-60 0.00 1.15E+04 1.48E+04 0.00 0.00 5.97E+06 2.85E+05 Ni-63 4.32E+05 3.14E+04 1.45E+04 0.00 0.00 1.78E+05 1.34E+04 Zn-65 3.24E+04 1.03E+05 4.66E+04 0.00 6.90E+04 8.64E+05 5.34E+04 Rb-86 0.00 1.35E+05 5.90E+04 0.00 0.00 0.00 1.66E+04 Sr-89 3.04E+05 0.00 8.72E+03 0.00 0.00 1.40E+06 3.50E+05 Sr-90 9.92E+07 0.00 6.1OE+06 0.00 0.00 9.60E+06 7.22E+05 Y-91 4.62E+05 0.00 1.24E+04 0.00 0.00 1.70E+06 3.85E+05 Zr-95 1.07E+05 3.44E+04 2.33E+04 0.00 5.42E+04 1.77E+06 1.50E+05 Nb-95 1.41E+04 7.82E+03 4.21E+03 0.00 7.74E+03 5.05E+05 1.04E+05 Ru-103 1.53E+03 0.00 6.58E+02 0.00 5.83E+03 5.05E+05 1.10E+05 Ru-106 6.91E+04 0.00 8.72E+03 0.00 1.34E+05 9.36E+06 9.12E+05 Ag-110m 1.08E+04 1.OOE+04 5.94E+03 0.00 1.97E+04 4.63E+06 3.02E+05 Sb-124 3.12E+04 5.89E+02 1.24E+04 7.55E+01 0.00 2.48E+06 4.06E+05 Sb-125 6.61E+04 7.13E+02 1.33E+04 5.87E+01 0.00 2.20E+06 1.01E+05 Te-125m 3.42E+03 1.58E+03 4.67E+02 1.05E+03 1.24E+04 3.14E+05 7.06E+04 Te-127m 1.26E+04 5.77E+03 1.57E+03 3.29E+03 4.58E+04 9.60E+05 1.50E+05 Te-129m 9.76E+03 4.67E+03 1.58E+03 3.44E+03 3.66E+04 1.16E+06 3.83E+05 1-131 2.52E+04 3.58E+04 2.05E+04 1.19E+07 6.13E+04 0.00 6.28E+03 1-133 8.64E+03 1.48E+04 4.52E+03 2.15E+06 2.58E+04 0.00 8.88E+03 Cs-134 3.73E+05 8.48E+05 7.28E+05 0.00 2.87E+05 9.76E+04 1.04E+04 Cs-136 3.90E+04 1.46E+05 1.1OE+05 0.00 8.56E+04 1.20E+04 1.17E+04 Cs-137 4.78E+05 6.21E+05 4.28E+05 0.00 2.22E+05 7.52E+04 8.40E+03 Ba-140 3.90E+04 4.90E+01 2.57E+03 0.00 1.67E+01 1.27E+06 2.18E+05 Ce-141 1.99E+04 1.35E+04 1.53E+03 0.00 6.26E+03 3.62E+05 1.20E+05 Ce-144 3.43E+06 1.43E+06 1.84E+05 0.00 8.48E+05 7.78E+06 8.16E+05 Pr-143 9.36E+03 3.75E+03 4.64E+02 0.00 2.16E+03 2.81E+05 2.OOE+05 Nd-147 5.27E+03 6.1OE+03 3.65E+02 0.00 3.56E+03 2.21E+05 1.73E+05 1. Units are (mremlyr)l(gCilm | |||
: 3) for all radionuclides. | |||
: 2. This table is included to support the calculations of section 6.2.3-45 VER 29 VEGP ODCM Table 3-11. Raipj for Cow Meat Pathway, Child Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 0.00 2.34E+02 2.34E+02 2.34E+02 2.34E+02 2.34E+02 2.34E+02 C-14 5.29E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 P-32 7.41E+09 3.47E+08 2.86E+08 0.00 0.00 0.00 2.05E+08 Cr-51 0.00 0.00 8.79E+03 4.88E+03 1.33E+03 8.91E+03 4.66E+05 Mn-54 0.00 8.01E+06 2.13E+06 0.00 2.25E+06 0.00 6.72E+06 Fe-55 4.57E+08 2.42E+08 7.51E+07 0.00 0.00 1.37E+08 4.49E+07 Fe-59 3.76E+08 6.09E+08 3.03E+08 0.00 0.00 1.77E+08 6.34E+08 Co-58 0.00 1.64E+07 5.02E+07 0.00 0.00 0.00 9.58E+07 Co-60 0.00 6.93E+07 2.04E+08 0.00 0.00 0.00 3.84E+08 Ni-63 2.91E+10 1.56E+09 9.91E+08 0.00 0.00 0.00 1.05E+08 Zn-65 3.75E+08 1.OOE+09 6.22E+08 0.00 6.30E+08 0.00 1.76E+08 Rb-86 0.00 5.77E+08 3.55E+08 0.00 0.00 0.00 3.71E+07 Sr-89 4.82E+08 0.00 1.38E+07 0.00 0.00 0.00 1.87E+07 Sr-90 1.04E+10 0.00 2.64E+09 0.00 0.00 0.00 1.40E+08 Y-91 1.80E+06 0.00 4.82E+04 0.00 0.00 0.00 2.40E+08 Zr-95 2.66E+06 5.85E+05 5.21E+05 0.00 8.38E+05 0.00 6.11E+08 Nb-95 3.1OE+06 1.21E+06 8.62E+05 0.00 1.13E+06 0.00 2.23E+09 Ru-103 1.55E+08 0.00 5.96E+07 0.00 3.90E+08 0.00 4.01E+09 Ru-106 4.44E+09 0.00 5.54E+08 0.00 5.99E+09 0.00 6.90E+10 Ag-110m 8.39E+06 5.67E+06 4.53E+06 0.00 1.06E+07 0.00 6.74E+08 Sb-124 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Sb-125 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Te-125m 5.69E+08 1.54E+08 7.59E+07 1.60E+08 0.00 0.00 5.49E+08 Te-127m 1.77E+09 4.78E+08 2.11E+08 4.24E+08 5.06E+09 0.00 1.44E+09 Te-129m 1.79E+09 5.OOE+08 2.78E+08 5.77E+08 5.26E+09 0.00 2.18E+09 1-131 1.65E+07 1.66E+07 9.46E+06 5.50E+09 2.73E+07 0.00 1.48E+06 1-133 5.67E-01 7.02E-01 2.66E-01 1.30E+02 1.17E+00 0.00 2.83E-01 Cs-134 9.22E+08 1.51E+09 3.19E+08 0.00 4.69E+08 1.68E+08 8.16E+06 Cs-136 1.62E+07 4.46E+07 2.88E+07 0.00 2.37E+07 3.54E+06 1.57E+06 Cs-137 1.33E+09 1.28E+09 1.88E+08 0.00 4.16E+08 1.50E+08 7.99E+06 Ba-140 4.38E+07 3.84E+04 2.56E+06 0.00 1.25E+04 2.29E+04 2.22E+07 Ce-141 2.22E+04 1.11E+04 1.64E+03 0.00 4.86E+03 0.00 1.38E+07 Ce-144 2.32E+06 7.26E+05 1.24E+05 0.00 4.02E+05 0.00 1.89E+08 Pr-143 3.34E+04 1.OOE+04 1.66E+03 0.00 5.43E+03 0.00 3.60E+07 Nd-147 1.17E+04 9.47E+03 7.33E+02 0.00 5.19E+03 0.00 1.50E+07 Units are (mremlyr)l(, Cilm 3) for tritium, and m 2.(mremlyr)I(ý,Cils) for all other radionuclides. | |||
3-46 VER 29 VEGP ODCM Table 3-12. Raipj for Garden Vegetation Pathway, Child Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI H-3 0.00 4.01E+03 4.01E+03 4.01E+03 4.01E+03 4.01E+03 4.01E+03 C-14 8.89E+08 1.78E+08 1.78E+08 1.78E+08 1.78E+08 1.78E+08 1.78E+08 P-32 3.37E+09 1.58E+08 1.30E+08 0.00 0.00 0.00 9.31E+07 Cr-51 0.00 0.00 1.17E+05 6.50E+04 1.78E+04 1.19E+05 6.21E+06 Mn-54 0.00 6.65E+08 1.77E+08 0.00 1.86E+08 0.00 5.58E+08 Fe-55 8.01E+08 4.25E+08 1.32E+08 0.00 0.00 2.40E+08 7.87E+07 Fe-59 3.98E+08 6.43E+08 3.20E+08 0.00 0.00 1.86E+08 6.70E+08 Co-58 0.00 6.44E+07 1.97E+08 0.00 0.00 0.00 3.76E+08 Co-60 0.00 3.78E+08 1.12E+09 0.00 0.00 0.00 2.1OE+09 Ni-63 3.95E+10 2.11E+09 1.34E+09 0.00 0.00 0.00 1.42E+08 Zn-65 8.13E+08 2.16E+09 1.35E+09 0.00 1.36E+09 0.00 3.80E+08 Rb-86 0.00 4.52E+08 2.78E+08 0.00 0.00 0.00 2.91E+07 Sr-89 3.60E+10 0.00 1.03E+09 0.00 0.00 0.00 1.39E+09 Sr-90 1.24E+12 0.00 3.15E+11 0.00 0.00 0.00 1.67E+10 Y-91 1.86E+07 0.00 4.99E+05 0.00 0.00 0.00 2.48E+09 Zr-95 3.86E+06 8.48E+05 7.55E+05 0.00 1.21E+06 0.00 8.85E+08 Nb-95 4.1OE+05 1.60E+05 1.14E+05 0.00 1.50E+05 0.00 2.96E+08 Ru-103 1.53E+07 0.00 5.90E+06 0.00 3.86E+07 0.00 3.97E+08 Ru-106 7.45E+08 0.00 9.30E+07 0.00 1.01E+09 0.00 1.16E+10 Ag-110m 3.21E+07 2.17E+07 1.73E+07 0.00 4.04E+07 0.00 2.58E+09 Sb-124 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Sb-1 25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Te-125m 3.51E+08 9.50E+07 4.67E+07 9.84E+07 0.00 0.00 3.38E+08 Te-127m 1.32E+09 3.56E+08 1.57E+08 3.16E+08 3.77E+09 0.00 1.07E+09 Te-129m 8.41E+08 2.35E+08 1.31E+08 2.71E+08 2.47E+09 0.00 1.03E+09 1-131 1.43E+08 1.44E+08 8.17E+07 4.75E+10 2.36E+08 0.00 1.28E+07 1-133 3.53E+06 4.37E+06 1.65E+06 8.11E+08 7.28E+06 0.00 1.76E+06 Cs-134 1.60E+10 2.63E+10 5.55E+09 0.00 8.15E+09 2.93E+09 1.42E+08 Cs-136 8.24E+07 2.27E+08 1.47E+08 0.00 1.21E+08 1.80E+07 7.96E+06 Cs-137 2.39E+10 2.29E+10 3.38E+09 0.00 7.46E+09 2.68E+09 1.43E+08 Ba-140 2.77E+08 2.42E+05 1.61E+07 0.00 7.89E+04 1.45E+05 1.40E+08 Ce-141 6.56E+05 3.27E+05 4.86E+04 0.00 1.43E+05 0.00 4.08E+08 Ce-144 1.27E+08 3.98E+07 6.78E+06 0.00 2.21E+07 0.00 1.04E+10 Pr-143 1.46E+05 4.37E+04 7.23E+03 0.00 2.37E+04 0.00 1.57E+08 Nd-147 7.15E+04 5.79E+04 4.48E+03 0.00 3.18E+04 0.00 9.17E+07 Units are (mremlyr)I(p.Cilm | |||
: 3) for tritium, and radionuclides. | |||
2 m .(mrem/yr)/(jiCi/s) for all other 3-47 VER29 VEGP ODCM 3.5 GASEOUS EFFLUENT DOSE PROJECTIONS 3.5.1 Thirty-One Day Dose Projections In order to meet the requirements of the limit for operation of the gaseous radwaste treatment system (see Section 3.1.5), dose projections must be made at least once each 31 days; this applies during periods in which a discharge to areas at or beyond the SITE BOUNDARY of gaseous effluents containing radioactive materials occurs or is expected.Projected 31-day air doses and doses to individuals due to gaseous effluents may be determined as follows: For air doses:= 7 Doc x 31+/-+ Dpa (3.16)Dy = ("- x 31 + Dya For individual doses: D=- -D-RZJ 31,+ D (3.17)where: Dpp = the projected air dose due to beta emissions from noble gases, for the next 31 days of gaseous releases.Dpc = the cumulative air dose due to beta emissions from noble gas releases that have occurred in the elapsed portion of the current quarter, plus the release under consideration. | |||
DOa = the anticipated air dose due to beta emissions from noble gas releases, contributed by any planned activities during the next 31-day period, if those activities will result in gaseous releases that are in addition to routine gaseous effluents. | |||
If only routine gaseous effluents are anticipated, DOa may be set to zero.Dyp = the projected air dose due to gamma emissions from noble gases for the next 31 days of gaseous releases.Dyc = the cumulative air dose due to gamma emissions from noble gas releases that have occurred in the elapsed portion of the current quarter, plus the release under consideration. | |||
3-48 VER 29 VEGP ODCM Dya = the anticipated air dose due to gamma emissions from noble gas releases, contributed by any planned activities during the next 31-day period, if those activities will result in gaseous releases that are in addition to routine gaseous effluents. | |||
If only routine gaseous effluents are anticipated, Dya may be set to zero.Dop = the projected dose to the total body or organ o, due to releases of I-131, 1-133, tritium, and particulates for the next 31 days of gaseous releases.Doc = the cumulative dose to the total body or organ o, due to releases of 1-131, 1-133, tritium, and particulates that have occurred in the elapsed portion of the current quarter, plus the release under consideration. | |||
Doa = the anticipated dose to the total body or organ o, due to releases of 1-131, 1-133, tritium, and particulates, contributed by any planned activities during the next 31-day period, if those activities will result in gaseous releases that are in addition to routine gaseous effluents. | |||
If only routine gaseous effluents are anticipated, Doa may be set to zero.t = the number of whole or partial days elapsed into the current quarter, including the time to the end of the release under consideration (even if the release continues into the next quarter).3.5.2 Dose Projections for Specific Releases Dose projections may be performed for a particular release by performing a pre-release dose calculation assuming that the planned release will proceed as anticipated. | |||
For air dose and individual dose projections due to gaseous effluent releases, follow the methodology of Section 3.4, using sample analysis results for the gaseous stream to be released, and parameter values expected to exist during the release period.3-49 VER 29 VEGP ODCM 3.6 DEFINITIONS OF GASEOUS EFFLUENT TERMS Section of Initial Term Definition Use AG = the administrative allocation factor for gaseous streams, applied to divide the gaseous release limit among all the release pathways [unitless]. | |||
3.3.2.1 AGs = the administrative allocation factor for gaseous source stream s, applied to divide the gaseous release limit among all the release pathways [unitless]. | |||
3.3.3 AGv = the administrative allocation factor for gaseous release pathway v, applied to divide the gaseous release limit among all the release pathways [unitless]. | |||
3.3.2.2 c = the setpoint of the radioactivity monitor measuring the concentration of radioactivity in the effluent line prior to release [jiCi/mL]. | |||
3.3.2.1 Cns = the calculated noble gas effluent monitor setpoint for gaseous source stream s [gCi/mL]. | |||
3.3.3 Cnv = the calculated noble gas effluent monitor setpoint for release pathway v [giCi/mL]. | |||
3.3.2.2 Dja = the dose to organ j of an individual in age group a, due to gaseous releases of 1-131, 1-133, tritium, and radionuclides in particulate form with half-lives greater than 3.4.3 8 days [mrem].Doa = the anticipated dose to organ o due to releases of non-noble-gas radionuclides, contributed by any planned activities during the next 31-day period [mrem]. 3.5.1 Do= the cumulative dose to organ o due to releases of non-noble-gas radionuclides that have occurred in the elapsed portion of the current quarter, plus the release under 3.5.1 consideration | |||
[mrem].Dop= the projected dose to organ o due to the next 31 days of gaseous releases of non-noble-gas radionuclides | |||
[mrem]. 3.5.1 D= the air dose due to beta emissions from noble gas radionuclides | |||
[mrad]. 3.4.2 3-50 VER 29 VEGP ODCM Section of Initial Term Definition Use Doa = the anticipated air dose due to beta emissions from noble gas releases, contributed by any planned activities during the next 31-day period [mrad]. 3.5.1 Doc = the cumulative air dose due to beta emissions from noble gas releases that have occurred in the elapsed portion of the current quarter, plus the release under consideration 3.5.1[mrad].DIp = the projected air dose due to beta emissions from noble gases, for the next 31 days of gaseous releases [mrad]. 3.5.1 DY= the air dose due to gamma emissions from noble gas radionuclides | |||
[mrad]. 3.4.2 Dya = the anticipated air dose due to gamma emissions from noble gas releases, contributed by any planned activities during the next 31-day period [mrad]. 3.5.1 Dyc = the cumulative air dose due to gamma emissions from noble gas releases that have occurred in the elapsed portion of the current quarter, plus the release under 3.5.1 consideration | |||
[mrad].Dyp = the projected air dose due to gamma emissions from noble gases, for the next 31 days of gaseous releases [mrad]. 3.5.1 (DIQ)vp = the annual average relative deposition factor for release pathway v, at the location of the controlling receptor, from 3.4.3 Table 3-7 [m-2].DRk = the skin dose rate at the time of the release [mrem/y]. | |||
3.4.1.1 DRo = the dose rate to organ o at the time of the release 3.4.1.2[mrem/y].DRt = the total body dose rate at the time of the release 3.4.1.1[mrem/y].fav = the maximum anticipated actual discharge flowrate for release pathway v during the period of the planned release 3.3.2.2[mL/s].fas = the maximum anticipated actual discharge flowrate for gaseous source stream s during the period of the planned 3.3.3 3-51 VER 29 VEGP ODCM Section of Initial Term Definition Use release [mL/s].Ki = the total body dose factor due to gamma emissions from noble gas radionuclide i, from Table 3-5 3.3.2.2[(mrem/y)l([.C i/m 3)].Li = the skin dose factor due to beta emissions from noble gas radionuclide i, from Table 3-5 [(mrem/y)/(ý.Cilm 3)]. 3.3.2.2 M= the air dose factor due to gamma emissions from noble gas radionuclide i, from Table 3-5 [(mradly)/(jICi/m 3)]. 3.4.2 N = the number of simultaneously active gaseous release pathways [unitless]. | |||
3.3.4 N = the air dose factor due to beta emissions from noble gas radionuclide i, from Table 3-5 [(mradly)/([iCilm 3)]. 3.4.2 Pio = the site-specific dose factor for radionuclide i (I-131, 1-133, tritium, and radionuclides in particulate form with half-lives greater than 8 days) and organ o. The values of P 0 , are equal to the site-specific Raipj values presented in 3.4.1.2 Table 3-9 [(mrem/y)/(jiCi/m 3)].Q= the release rate of noble gas radionuclide i from release pathway v during the period of interest [pCi/s]. 3.3.2.2 Q'iv= the release rate of radionuclide i (1-131, 1-133, tritium, and radionuclides in particulate form with half-lives greater than 8 days) from gaseous release pathway v during the period of interest [pCi/s]. 3.4.1.2 v= the cumulative release of noble gas radionuclide i from release pathway v during the period of interest [ptCi]. 3.4.2the cumulative release of non-noble-gas radionuclide i from release pathway v, during the period of interest [pCi]. 3.4.3 Raipj = the site-specific dose factor for age group a, radionuclide i, exposure pathway p, and organ j. Values and units of Raipj for each exposure pathway, age group, and radionuclide that may arise in calculations for implementing Section 3.1.4 are listed in Table 3-8 through Table 3-9. 3.4.3 3-52 VER 29 VEGP ODCM Section of Initial Term Definition Use Rk = the ratio of the skin dose rate limit for noble gases, to the skin dose rate due to noble gases in the release under consideration | |||
[unitless]. | |||
3.3.2.1 Rt = the ratio of the total body dose rate limit for noble gases, to the total body dose rate due to noble gases in the release under consideration | |||
[unitless]. | |||
3.3.2.1 rk = the ratio of the skin dose rate limit for noble gases, to the skin dose rate due to noble gases in the source stream under consideration | |||
[unitless]. | |||
3.3.3.1 rt = the ratio of the total body dose rate limit for noble gases, to the total body dose rate due to noble gases in the source stream under consideration | |||
[unitless]. | |||
3.3.3.1 SF = the safety factor used in gaseous setpoint calculations to compensate for statistical fluctuations and errors of measurement | |||
[unitless]. | |||
3.3.2.2 t =the number of whole or partial days elapsed in the current quarter, including the period of the release under 3.5.1 consideration. | |||
Wvip = the annual average relative dispersion | |||
[(X-IQ--)P] | |||
or deposition | |||
[(IQ-)-Pv] | |||
at the location of the controlling receptor, for release pathway v, as appropriate to 3.4.3 exposure pathway p and radionuclide i.X = the noble gas concentration for the release under consideration | |||
[pCi/mL]. | |||
3.3.2.1 Xir = the concentration of radionuclide i applicable to active gaseous release pathway r [pCi/mL]. | |||
3.3.4 Xis = the measured concentration of radionuclide i in gaseous source stream s [pCi/mL]. | |||
3.3.3 3-53 VER 29 VEGP ODCM Section of Initial Term Definition Use A= the measured concentration of radionuclide i in gaseous stream v [IuCi/mL]. | |||
3.3.2.2 (X/Q) = the highest relative concentration at any point at or beyond the SITE BOUNDARY [s/m 3]. 3.3.2.1 (x-'-IQ),= | |||
the annual average SITE BOUNDARY relative concentration applicable to active gaseous release 3.3.4 pathway r [s/m3].= the highest annual average relative concentration at the SITE BOUNDARY for the discharge point of release pathway v, from Table 3-4 [s/m 3]. 3.3.2.2 I-Q-)IP = annual average relative dispersion factor for release pathway v, at the location of the controlling receptor, from 3.4.3 Table 3-7 [s/m 3].3-54 VER 29 VEGP ODCM CHAPTER 4 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM 4.1 LIMITS OF OPERATION The following limits are the same for both units at the site. Thus, a single program including monitoring, land use survey, and quality assurance serves both units.4.1.1 Radiological Environmental Monitoring The Radiological Environmental Monitoring Program (REMP) shall be conducted as specified in Table 4-1.4.1.1.1 Applicability This control applies at all times.4.1.1.2 Actions 4.1.1.2.1 With the REMP not being conducted as specified in Table 4-1, submit to the Nuclear Regulatory Commission (NRC), in the Annual Radiological Environmental Operating Report, a description of the reasons for not conducting the program as required and the plans for preventing a recurrence. | |||
Deviations from the required sampling schedule are permitted if specimens are unobtainable due to hazardous conditions, unavailability, inclement weather, equipment malfunction, or other just reasons. If deviations are due to equipment malfunction, efforts shall be made to complete corrective action prior to the end of the next sampling period.4.1.1.2.2 With the confirmed 1 measured level of radioactivity as a result of plant effluents in an environmental sampling medium specified in Table 4-1 exceeding the reporting levels of Table 4-2 when averaged over any calendar quarter, submit within 30 days a special report to the NRC. The special report shall identify the cause(s) for exceeding the limit(s) and define the corrective action(s) to be taken to reduce radioactive effluents so that the potential annual dose to a MEMBER OF THE PUBLIC is less than the calendar year limits of Sections 2.1.3, 3.1.3, and 3.1.4. The methodology and parameters used to estimate the potential annual dose to a MEMBER OF THE PUBLIC shall be indicated in the special report.When more than one of the radionuclides in Table 4-2 are detected in the sampling medium, this report shall be submitted if: Defined as confirmed by reanalysis of the original sample, or analysis of a duplicate or new sample, as appropriate. | |||
The results of the confirmatory analysis shall be completed at the earliest time consistent with the analysis.4-1 VER 29 VEGP ODCM concentrat ion (1) concentrat ion (2) + ... > 1.0 reporting level (1) reporting level (2)When radionuclides other than those in Table 4-2 are detected and are the result of plant effluents, this special report shall be submitted if the potential annual dose to a MEMBER OF THE PUBLIC is equal to or greater than the calendar year limits stated in Sections 2.1.3, 3.1.3, and 3.1.4. This special report is not required if the measured level of radioactivity was not the result of plant effluents; however, in such an event, the condition shall be described in the Annual Radiological Environmental Operating Report. The levels of naturally-occurring radionuclides which are not included in the plant's effluent releases need not be reported.4.1.1.2.3 If adequate samples of milk, or during the growing season, grass or leafy vegetation, can no longer be obtained from one or more of the sample locations required by Table 4-1, or if the availability is frequently or persistently wanting, efforts shall be made: to identify specific locations for obtaining suitable replacement samples;and to add any replacement locations to the REMP given in the ODCM within 30 days.The specific locations from which samples became unavailable may be deleted from the REMP. Pursuant to Technical Specification 5.5.1, documentation shall be submitted in the next Radioactive Effluent Release Report for the change(s) in the ODCM, including revised figure(s) and table(s) reflecting the changes to the location(s), with supporting information identifying the cause of the unavailability of samples and justifying the selection of any new location(s). | |||
4.1.1.2.4 This control does not affect shutdown requirements or MODE changes.4.1.1.3 Surveillance Requirements The REMP samples shall be collected pursuant to Table 4-1 from the locations described in Section 4.2, and shall be analyzed pursuant to the requirements of Table 4-1 and Table 4-3. Required detection capabilities for thermoluminescent dosimeters used for environmental measurements shall be in accordance with the recommendations of Regulatory Guide 4.13. Program changes may be initiated based on operational experience. | |||
Analyses shall be performed in such a manner that the stated MINIMUM DETECTABLE CONCENTRATIONs (MDCs) will be achieved under routine conditions. | |||
Occasionally background fluctuations, unavoidable small sample sizes, the presence of interfering radionuclides, or other uncontrollable circumstances may render these MDCs unachievable. | |||
In such cases, the contributing factors will be identified and described in the Annual Radiological Environmental Operating Report.4.1.1.4 Basis 4-2 VER 29 VEGP ODCM The REMP required by this control provides representative measurements of radiation and of radioactive materials in those exposure pathways, and for those radionuclides, which lead to the highest potential radiation exposures of MEMBERS OF THE PUBLIC resulting from the plant operation. | |||
The REMP implements Section IV.B.2, Appendix I, 10 CFR 50, and thereby supplements the radiological effluent monitoring program by measuring concentrations of radioactive materials and levels of radiation, which may then be compared with those expected on the basis of the effluent measurements and modeling of the environmental exposure pathways.The detection capabilities required by Table 4-3 are within state-of-the-art for routine environmental measurements in industrial laboratories. | |||
4-3 VER 29 VEGP ODCM Table 4-1. Radiological Environmental Monitoring Program Exposure Number of Representative Samples and Sample Sampling and Type and Pathway Locations(l) | |||
Collection Frequency of and/or Sample Frequency Analysis 1. DIRECT RADIATION Direct Thirty-six or more routine monitoring stations, either Quarterly. | |||
Gamma dose Radiation(2) with two or more dosimeters, or with one instrument quarterly. | |||
for measuring and recording dose rate continuously, placed as follows: An inner ring of stations, one in each meteorological sector in the general area of the site boundary.An outer ring of stations, one in each meteorological sector at approximately 5 miles from the site.The balance of the stations to be placed in special interest areas such as population centers, nearby residences, schools, and in one or more areas to serve as control stations.2. AIRBORNE Radioiodine Samples from 5 or more locations as follows: Continuous Radioiodine and sampler operation Canister: | |||
1-131 Particulates Three or more samples from close to the three site with sample analysis weekly.boundary locations, in different sectors. collection weekly, or more frequently Particulate One sample from the vicinity of a community having if required by dust Sampler: Gross the highest calculated annual average ground-level loading, beta radioactivity D/Q. analysis following filter change, and One sample from a control location, as, for example, gamma isotopic a population center 10 to 20 miles distant and in the analysis of least prevalent wind direction. | |||
composite (by location)quarterly.(3)(4) 4-4 VER 29 VEGP ODCM Table 4-1. Radiological Environmental Monitoring Program Exposure Number of Representative Samples Sampling and Collection Type and Frequency of Pathway and Sample Locations(I) | |||
Frequency Analysis and/or Sample 3. WATERBORNE Surface(5) | |||
One sample upstream. | |||
Composite sample over Gamma isotopic analysis 1-month period.(6) monthly; composite for One sample downstream. | |||
tritium analysis quarterly.(4) | |||
Drinking Two samples at each of the one to Composite sample of river 1-131 analysis on each three nearest water treatment plants water near intake at each sample when the dose that could be affected by discharges water treatment plant over calculated for the from the facility. | |||
2-week period when 1-131 consumption of the water is analysis is performed, greater than 1 mrem per Two samples at a control location, monthly composite year. Composite for gross otherwise; and grab sample beta and gamma isotopic of finished water at each analyses monthly.water treatment plant every Composite for tritium 2 weeks or monthly, as analysis quarterly.(4)(7) appropriate.(6) | |||
Sediment from One sample from downstream area Semiannually. | |||
Gamma isotopic analysis Shoreline with existing or potential recreational semi-annually.(4) value.Groundwater An adequate number of onsite wells Quarterly Tritium and gamma to provide detection of radioactive isotopic quarterly. | |||
Other liquid releases into the groundwater analyses based on results from tanks, underground piping, and of tritium and gamma.other plant equipment. | |||
At least one well at a control location.4-5 VER 29 VEGP ODCM Table 4-1. Radiological Environmental Monitoring Program Exposure Number of Representative Samples and Sample Sampling and Type and Pathway Locations(I) | |||
Collection Frequency of and/or Sample Frequency Analysis 4. INGESTION Milk Samples from milking animals in three locations within Semimonthly. | |||
Gamma 3 miles distance having the highest dose potential; if there isotopic are none, then one sample from milking animals in each of analysis semi-three areas between 3 and 5 miles distance where doses monthly.(4)(8) are calculated to be greater than 1 mrem per year.(7)One sample from milking animals at a control location about 10 miles distant or beyond, and preferably in a wind direction of low prevalence. | |||
Fish At least one sample of any commercially and recreationally Semiannually. | |||
Gamma important species in vicinity of plant discharge area. isotopic analyses on At least one sample of any species in areas not influenced edible by plant discharge. | |||
portions.(4) | |||
At least one sample of any anadromous species in vicinity of During spring Gamma plant discharge. | |||
spawning isotopic season. analyses on edible portion.(4) | |||
Grass or One sample from two onsite locations near the site boundary Monthly during Gamma Leafy in different sectors. growing season. isotopic.(4)(8) | |||
Vegetation____________ | |||
____One sample from a control location about 15 miles distant. Monthly during Gamma growing season, isotopic.(4)(8) 4-6 VER 29 VEGP ODCM Table 4-1. Radiological Environmental Monitoring Program TABLE NOTATIONS (1) For each sample location in this table, specific parameters of distance and direction sector from a point midway between the center of the two reactors, and additional description where pertinent, are provided in Table 4-4, and in Figure 4-1 through Figure 4-4 of this ODCM.(2) One or more instruments, such as a pressurized ion chamber, for measuring and recording dose rate continuously, may be used in place of or in addition to integrating dosimeters. | |||
For the purpose of this table, a thermoluminescent dosimeter (TLD) is considered to be one phosphor; two or more phosphors in a packet are considered as two or more dosimeters. | |||
Film badges shall not be used as dosimeters for measuring direct radiation. | |||
(3) Airborne particulate sample filters shall be analyzed for gross beta radioactivity 24 hours or more after sampling to allow for radon and thoron daughter decay. If gross beta activity in air particulate samples is greater than 10 times the yearly mean of control samples, gamma isotopic analysis shall be performed on the individual samples.(4) Gamma isotopic analysis means the identification and quantification of gamma-emitting radionuclides that may be attributable to the effluents from the facility.(5) The upstream sample shall be taken at a distance beyond significant influence of the discharge. | |||
The downstream sample shall be taken in an area beyond but near the mixing zone.(6) Composite sample aliquots shall be collected at time intervals that are very short (e.g., hourly) relative to the compositing period (e.g., monthly) in order to assure obtaining a representative sample.(7) The dose shall be calculated for the maximum organ and age group, using the methodology and parameters in the ODCM.(8) If gamma isotopic analysis is not sensitive enough to meet the required MDC for 1-131, a separate analysis for 1-131 will be performed. | |||
4-7 VER 29 VEGP ODCM Table 4-2. Reporting Levels for Radioactivity Concentrations in Environmental Samples Water Airborne Fish Milk Grass or Leafy ApalyLi Particulate or Vegetation | |||
______ Gases (pCi/m 3) (pCi/kg, wet) (pCi/L) (pCi/kg, wet)H-3 2 E+4a Mn-54 1 E+3 3 E+4 Fe-59 4 E+2 1 E+4 Co-58 1 E+3 3 E+4 Co-60 3 E+2 1 E+4 Zn-65 3 E+2 2 E+4 Zr-95 4 E+2 Nb-95 7 E+2 1-131 2 E+Ob 9 E-1 3 E+0 1 E+2 Cs-134 3 E+1 1 E+1 1 E+3 6 E+1 1 E+3 Cs-137 5 E+1 2 E+1 2 E+3 7 E+1 2 E+3 Ba-140 2 E+2 3 E+2 La-140 1 E+2 0 E+2 a. This is the 40 CFR 141 value for drinking water samples. If no drinking water pathway exists, a value of 3 E+04 pCi/L may be used.b. If no drinking water pathway exists, a value of 20 pCi/L may be used.4-8 VER 29 VEGP ODCM Table 4-3. Values for the Minimum Detectable Concentration (MDC)Minimum Detectable Concentration (MDC)a Water Airborne Fish Milk Grass or Leafy Sediment AnlssParticulate or Vegetation Analysis (pCi/L) G ase p r (pCi/kg, wet) (pCi/L) (iget) (pCi/kg, dry)Gases (p Ci/m3) (C(pCi/kg, wet)Gross Beta 4 E+O 1 E-2 H-3 2 E+3b Mn-54 1.5 E+1 1.3 E+2 Fe-59 3 E+1 2.6 E+2 Co-58, Co-60 1.5 E+1 1.3 E+2 Zn-65 3 E+1 2.6 E+2 Zr-95 3 E+1 Nb-95 1.5 E+1 1-131 1 E+Oc 7 E-2 1 E+0 6 E+1 Cs-134 1.5 E+1 5 E-2 1.3 E+2 1.5 E+1 6 E+1 1.5 E+2 Cs-137 1.8 E+1 6 E-2 1.5 E+2 1.8 E+1 8 E+1 1.8 E+2 Ba-140 6 E+1 6 E+1 La-140 1.5 E+1 1.5 E+1 a. See the definition of MINIMUM DETECTABLE CONCENTRATION in Section 10.1. Other peaks which are measurable and identifiable as plant effluents, together with the radionuclides in this table, shall be analyzed and reported in accordance with Section 7.1.b. If no drinking water pathway exists, a value of 3 E+3 pCi/L may be used.c. If no drinking water pathway exists, a value of 1.5 E+1 pCi/L may be used.4-9 VER 29 VEGP ODCM 4.1.2 Land Use Census A land use census shall be conducted and shall identify the following within a distance of 5 miles in each of the 16 meteorological sectors: the location of the nearest milk animal, 1 the nearest permanent residence, and the nearest garden of greater than 500 square feet producing broad leafy vegetation. | |||
Land within the Savannah River Site is excluded from this census.4.1.2.1 Applicability This control applies at all times.4.1.2.2 Actions 4.1.2.2.1 With a land use census identifying a location(s) which yields a calculated dose or dose commitment greater than values currently being calculated in accordance with Section 3.4.3, identify the new location(s) in the next Radioactive Effluent Release Report.4.1.2.2.2 With a land use census identifying a location(s) which yields a calculated dose or dose commitment (via the same exposure pathway) 20 percent greater than at a location from which samples are currently being obtained in accordance with Section 4.1.1, add the new location(s) to the REMP within 30 days if samples are available. | |||
The sampling location, excluding control station location(s), having the lowest calculated dose or dose commitment (via the same exposure pathway) may be deleted from the REMP if new sampling locations are added. Pursuant to Technical Specification | |||
====5.5.1 submit==== | |||
in the next Radioactive Effluent Release Report any change(s) in the ODCM, including the revised figure(s) and table(s) reflecting any new location(s) and information supporting the change(s). | |||
4.1.2.2.3 This control does not affect shutdown requirements or MODE changes.4.1.2.3 Surveillance Requirements The land use census shall be conducted annually, using that information which will provide good results, such as a door-to-door census, a visual census from automobile or aircraft, consultation with local agriculture authorities, or some combination of these methods, as feasible. | |||
Results of the land use census shall be included in the Annual Radiological Environmental Operating Report.4.1.2.4 Basis This control is provided to ensure that changes in the use of UNRESTRICTED AREAS are identified and that modifications to the REMP are made if required by the results of this census. This census satisfies the requirements of Section IV.B.3 of Appendix I to 10 CFR 1 Defined as a cow or goat that is producing milk for human consumption. | |||
4-9 VER 29 VEGP ODCM Part 50. Restricting the census to gardens of greater than 500 ft 2 provides assurance that significant exposure pathways via leafy vegetables will be identified and monitored since a garden of this size is the minimum required to produce the quantity (26 kg/y) of leafy vegetables assumed in Regulatory Guide 1.109 for consumption by a child. To determine this minimum garden size, the following assumptions were made: (1) 20 percent of the garden was used for growing broad leaf vegetation (i.e., similar to lettuce and cabbage) and (2) a vegetation yield of 2 kg/M 2 was obtained.4.1.3 Interlaboratory Comparison Program Analyses shall be performed on radioactive materials supplied as part of an Interlaboratory Comparison Program which satisfies the requirements of Regulatory Guide 4.15, Revision 1, February, 1979.4.1.3.1 Applicability This control applies at all times.4.1.3.2 Actions With analyses not being performed as required by Section 4.1.3, report the corrective actions taken to prevent a recurrence in the Annual Radiological Environmental Operating Report.This control does not affect shutdown requirements or MODE changes.4.1.3.3 Surveillance Requirements A summary of the results obtained as part of the required Interlaboratory Comparison Program shall be included in the Annual Radiological Environmental Operating Report.4.1.3.4 Basis The requirement for participation in an approved Interlaboratory Comparison Program is provided to ensure that independent checks on the precision and accuracy of the measurements of radioactive material in environmental sample matrices are performed as part of the quality assurance program for environmental monitoring, in order to demonstrate that the results are reasonably valid for the purposes of Section IV.B.2, Appendix 1, 10 CFR 50.4-10 VER 29 VEGP ODCM 4.2 RADIOLOGICAL ENVIRONMENTAL MONITORING LOCATIONS Table 4-4 and Table 4-5 and Figure 4-1 through Figure 4-5 specify the locations at which the measurements and samples are taken for the REMP required by Section 4.1.1.4-i 1 VER29 4-11 VER 29 VEGP ODCM Table 4-4. Radiological Environmental Monitoring Locations Location Descriptive Location Direction Distance Sample Number (miles) Type(1)1 River Bank N 1.1 D 2 River Bank NNE 0.8 D 3 Discharge Area NE 0.6 A 3 River Bank NE 0.7 D 4 River Bank ENE 0.8 D 5 River Bank E 1.0 D 6 Plant Wilson ESE 1.1 D 7 Simulator Building SE 1.7 D,V,A 8 River Road SSE 1.1 D 9 River Road S 1.1 D 10 Met Tower SSW 0.9 A 10 River Road SSW 1.1 D 11 River Road SW 1.2 D 12 River Road WSW 1.2 D,A 13 River Road W 1.3 D 14 River Road WNW 1.8 D 15 Hancock Landing Road NW 1.5 D,V 16 Hancock Landing Road NNW 1.4 D,A 17 Savannah River Site, River Road N 5.4 D 18 Savannah River Site, D Area NNE 5.0 D 19 Savannah River Site, Road A.13 NE 4.6 D 20 Savannah River Site, Road A.13.1 ENE 4.8 D 21 Savannah River Site, Road A.17 E 5.3 D 22 River Bank Downstream of Buxton ESE 5.2 D Landing 23 River Road SE 4.6 D 24 Chance Road SSE 4.9 D 25 Chance Road near Highway 23 S 5.2 D 26 Highway 23 and Ebenezer Church SSW 4.6 D Rd.4-12 VER 29 VEGP ODCM Table 4-4 (contd).Radiological Environmental Monitoring Locations Location Descriptive Location Direction Distance Sample Number (miles) Type(l)27 Highway 23, opposite Boll Weevil SW 4.7 D Road 28 Thomas Road WSW 5.0 D 29 Claxton-Lively Road W 5.1 D 30 Nathaniel Howard Road WNW 5.0 D 31 River Road at Allen's Chapel Fork NW 5.0 D 32 River Bank NNW 4.7 D 35 Girard SSE 6.6 D,A 36 GPC Waynesboro Operating WSW 13.9 D,A Headquarters 37 Substation; Waynesboro, GA WSW 16.7 D,V 43 Employees Recreation Area SW 2.2 D 47 Oak Grove Church SE 10.4 D 48 McBean Cemetery NW 10.2 D 51 SGA School; Sardis, GA S 11.0 D 52 Oglethorp Substation; SW 10.7 D Alexander, GA 80 Augusta Water Treatment Plant NNW 29.0 W(2)81 Savannah River N 2.5 F(3),S(4)82 Savannah River (RM 151.2) NNE 0.8 R 83 Savannah River (RM 150.4) ENE 0.8 R, S(4)84 Savannah River (RM 149.5) ESE 1.6 R 85 Savannah River ESE 4.3 F(3)87 Beaufort -Jasper Water Treatment SE 76.0 W(5)Plant; Beaufort, SC 88 Cherokee Hill Water Treatment SSE 72.0 W(6)Plant; Port Wentworth, GA 89 Purrysburg Water Treatment Plant; SSE 76.0 W(7)Purrysburg, SC 101 Girard Dairy S 5.5 M 102 Seven Oaks Dairy w 7.5 M 4-13 VER 29 VEGP ODCM Table 4-4 (cont.) Radiological Environmental Monitoring Locations TABLE NOTATIONS (1) Sample Types: A -Airborne Radioactivity D -Direct Radiation F -Fish M -Milk R -River Water S -River Shoreline Sediment W -Drinking Water (at water treatment plant)V -Vegetation (2) The intake for the Augusta Water Treatment Plant is located on the Augusta Canal. The entrance to this canal is at river mile (RM) 207 on the Savannah River. The canal effectively parallels the river. The intake to the pumping station is about 4 miles down the canal and only 0.1 mile from the river (across land).(3) About a 5-mile stretch of the river is generally needed to obtain adequate fish samples.Samples are normally gathered between RM 153 and 158 for upriver collections and between RMs 144 and 149.4 for downriver collections. | |||
(4) Sediment is collected at locations with existing or potential recreational value. High water shifting of the river bottom or other reasons could cause a suitable location for sediment collection to become unavailable or unsuitable. | |||
Thus, a stretch of river between RM 148.5 and 150.5 is designated for downriver sediment collections, while a stretch between RM 153 and 154 is designated for upriver collections. | |||
In practice, collections are normally made at RM 150.2 for downriver collections and at RM 153.3 for upriver collections. | |||
(5) The intake for the Beaufort-Jasper Water Treatment Plant is located at the end of a canal which begins at RM 39.3 on the Savannah River. This intake is about 16 miles by line of sight down the canal from its beginning on the Savannah River.(6) The intake for the Cherokee Hill Water Treatment Plant is located on Abercorn Creek, which is about one and a quarter creek miles from its mouth on the Savannah River at RM 29.(7) The intake for the Purrysburg Water Treatment Plant is located on the same canal as the Beaufort-Jasper Water Treatment Plant. The Purrysburg intake is nearer to the Savannah River at the beginning of the canal.4-14 VER 29 4-14 VFR 29 VEGP ODCM Table 4-5. Groundwater Monitoring Locations WELL AQUIFER MONITORING PURPOSE LT-1 B Water Table NSCW related tank LT-7A Water Table NSCW related tank LT-1 2 Water Table NSCW related tank LT-1 3 Water Table NSCW related tank 802A Water Table Southeastern potential leakage 803A* Water Table Up gradient to rad waste building Down gradient from rad waste bldg and NSCW related facilities 806B Water Table Dilution line 808 Water Table Up gradient; along Pen Branch Fault NSCW related tank; western potential RI Water Tablelekg leakage R2 Water Table Southern potential leakage R3 Water Table Eastern potential leakage R4 Water Table Dilution line R5 Water Table Dilution line R6 Water Table Dilution line R7 Water Table Dilution line R8 Water Table Dilution line 1014 Tertiary Up gradient 1015 Water Table Vertically up gradient 27 Tertiary Down gradient tertiary 29 Tertiary Down gradient tertiary MU-1 Tertiary/Cretaceous Facility water supply River N/A Surface water* May need to be abandoned in the future due to construction activities (REF 23).4-15 VER 29 VEGP ODCM j 4w~91-65,,.) -" 4FA Figure 4-1. Terrestrial Stations Near Site Boundary 4-16 VER29 4-16 VER 29 VEGP ODCM-I .I Figure 4-2. Terrestrial Stations and Aquatic Stations, 0-5 Miles 4-17 VER29 4-17 VER 29 VEGP ODCM Figure 4-3. Terrestrial Stations Beyond 5 Miles 4-18 VER29 4-18 VER 29 VEGP ODCM SO VEGP.Canal to Sup Water to B GEORGIA PURRYSBURG WATER TREATMENT PLANT 0 10 2V 30 CHEROKEE HILL WATER TREATMENT PLANT (PORT WENTWORTH) | |||
UTH CAROLINA ply River eaufort Beaufort Jasper County Water Treatment Plant C., V,0 Figure 4-4. Drinking Water Stations 4-19 VER 29 VEGPODCM 11>6'4 5" NEV BARGE rALMJ1 OPTION I 0,. ST DOMRIS BASIN DiAM ,'-..0 OW-1005 179 0 519 27 A\ "9 El Ow-r 0 OW. 1009 m-- p!ont-3 0 0 oO-0C p 1 01t -2 _"--j .520OW W27% I.-t Te~rt~a ocd or mon.Ier.P wi.OV--1 -1012 ULi-2\2' ,V,' V.i L3c L"c. -dc 01cr, 9 ,'- c m o cl 9 1 1 ic'1 4-20 VER 29 VEGPODCM Figure 4-5 Groundwater Monitoring Wells 4-21 VER29 4-21 VER 29 VEGP ODCM CHAPTER 5 TOTAL DOSE DETERMINATIONS | |||
===5.1 LIMIT=== | |||
OF OPERATION In accordance with Technical Specification 5.5.4.j, the dose or dose commitment to any MEMBER OF THE PUBLIC over a calendar year, due to releases of radioactivity and to radiation from uranium fuel cycle sources, shall be limited to less than or equal to 25 mrem to the total body or any organ, except the thyroid, which shall be limited to less than or equal to 75 mrem.5.1.1 Applicability This limit applies at all times.5.1.2 Actions With the calculated doses from the release of radioactive materials in liquid or gaseous effluents exceeding twice the limits of Section 2.1.3, 3.1.3, or 3.1.4, calculations shall be made according to Section 5.2 methods to determine whether the limits of Section 5.1 have been exceeded. | |||
If these limits have been exceeded, prepare and submit a special report to the Nuclear Regulatory Commission within 30 days, which defines the corrective actions to be taken to reduce subsequent releases to prevent recurrence of exceeding the limits of Section 5.1 and includes the schedule for achieving conformance with the limits of Section 5.1. This special report, as defined in 10 CFR 20.2203, shall also include an analysis which estimates the radiation exposure (dose) to a MEMBER OF THE PUBLIC from uranium fuel cycle sources (including all effluent pathways and direct radiation) for the calendar year that includes the release(s) covered by this report. This special report shall also describe the levels of radiation and concentrations of radioactive material involved, and the cause of the exposure levels or concentrations. | |||
If the estimated dose(s) exceeds the limits of Section 5.1, and if the release condition resulting in violation of the provisions of 40 CFR 190 has not already been corrected, the special report shall include a request for variance in accordance with the provisions of 40 CFR 190 and including the specified information of 40 CFR 190.11 (b). Submittal of the report is considered a timely request, and a variance is granted until staff action on the request is complete.This control does not affect shutdown requirements or MODE changes.5.1.3 Surveillance Requirements Cumulative dose contributions from liquid and gaseous effluents and from direct radiation shall be determined in accordance with Section 5.2. This requirement is applicable only under the conditions set forth above in Section 5.1.2.5.1.4 Basis 5-1 VER 29 VEGP ODCM This control is provided to meet the dose limitations and reporting requirements of 40 CFR 190. The control requires the preparation and submittal of a special report whenever the calculated doses from plant radioactive effluents exceed the limits of Section 5.1. For sites containing up to 4 reactors, it is highly unlikely that the resultant dose to a MEMBER OF THE PUBLIC will exceed the dose limits of 40 CFR 190 if the individual reactors remain within twice the dose design objectives of Appendix I and if direct radiation doses from the units, such as direct exposure from outside storage tanks, are kept small. The special report will describe a course of action which should result in the limitation of dose to a MEMBER OF THE PUBLIC for a calendar year to within the 40 CFR 190 limits. For the purposes of the special report, it may be assumed that the dose commitment to the MEMBER OF THE PUBLIC from other uranium fuel cycle sources is negligible with the exception that dose contributions from other uranium fuel cycle facilities at the same site or within a radius of 5 miles must be considered. | |||
If the dose to any MEMBER OF THE PUBLIC is estimated to exceed the requirements of 40 CFR 190, the special report with a request for variance (provided the release conditions resulting in violation of 40 CFR 190 have not already been corrected), in accordance with the provisions of 40 CFR 190.11 and 10 CFR 20.2203(a)(4), is considered to be a timely request and fulfills the requirements of 40 CFR 190 until NRC staff action is completed. | |||
The variance only relates to the limits of 40 CFR 190, and does not apply in any way to the requirements for dose limitation as addressed in other sections of this ODCM. An individual is not considered a MEMBER OF THE PUBLIC during any period in which he/she is engaged in carrying out any operation which is part of the nuclear fuel cycle.5-2 VER 29 VEGP ODCM 5.2 DEMONSTRATION OF COMPLIANCE There are no other uranium fuel cycle facilities within 5 miles of the plant site.Therefore, for the purpose of demonstrating compliance with the limits of Section 5.1, the total dose to a MEMBER OF THE PUBLIC in the vicinity of the plant site due to uranium fuel cycle sources shall be determined as follows: DTk = DL + DG +Do + DN (5.1)where: DTk = the total dose or dose commitment to the total body or organ k, in mrem.DL = the dose to the same organ due to radioactivity discharged from the plant site in liquid effluents, calculated in accordance with Section 2.4.1, in mrem.DG = the dose to the same organ due to non-noble-gas radionuclides discharged from the plant site in gaseous effluents, calculated for the controlling receptor in accordance with Section 3.4.3, in mrem.DD = the direct radiation dose to the whole body of an individual at the controlling receptor location, due to radioactive materials retained within the plant site, in mrem. Values of direct radiation dose may be determined by measurement, calculation, or a combination of the two.DN = the external whole body dose to an individual at the controlling receptor location, due to gamma ray emissions from noble gas radionuclides discharged from the plant site in gaseous effluents, in mrem. DN is calculated as follows (equation adapted from Reference 1, page 22, by recasting in cumulative dose form): DN =3.17x1O8Z{X/Q)vp[K.j (5.2)where: 3.17 x 10-8 = a units conversion factor: 1 y/(3.15 x 10 7 s).(iv = the cumulative release of noble gas radionuclide i from release pathway v (pICi), during the period of interest.Ki =the total-body dose factor due to gamma emissions from noble gas radionuclide i (mrem/y)/(ýt Ci/m 3), from Table 3-5.5-3 VER29 5-3 VER 29 VEGP ODCM (XE-Q-)I = annual average relative dispersion factor for release pathway v, at the location of the controlling receptor, from Table 3-7[s/m 3].As defined above, DL and DG are for different age groups, while DD and DN are not age group specific. | |||
When a more precise determination of DTk is desired, values of DL and DG may be calculated for all four age groups, and those values used in equation (5.1) to determine age group specific values of DTk; the largest value of DTk for any age group may then be compared to the limits of Section 5.1.5-4 VER 29 VEGP ODCM CHAPTER 6 POTENTIAL DOSES TO MEMBERS OF THE PUBLIC DUE TO THEIR ACTIVITIES INSIDE THE SITE BOUNDARY 6.1 REQUIREMENT FOR CALCULATION To support the reporting requirements of Section 7.2.2.3, an assessment of the radiation doses from radioactive liquid and gaseous effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY shall be performed as specified in Section 6.2, at least once per calendar year.6.2 CALCULATIONAL METHOD For the purpose of performing the calculations required in Section 6.1, the dose to a member of the public inside the SITE BOUNDARY shall be determined at the locations, and for the receptor age groups, defined in Table 6-1. The dose to such a receptor at any one of the defined locations shall be determined as follows: Dik = [DA +DS +DP]'F. (6.1)where: Dik = the total dose to the total body or organ k, in mrem.DA = the dose to the same organ due to inhalation of non-noble-gas radionuclides discharged from the plant site in gaseous effluents, calculated in accordance with Section 3.4.3, in mrem. The FX1Q) value to be used is given for each receptor location in Table 6-1; depleted AM values may be used in calculations for non-noble-gas radionuclides. | |||
Ds = the dose to the same organ due to ground plane deposition of non-noble-gas radionuclides discharged from the plant site in gaseous effluents, calculated in accordance with Section 3.4.3, in mrem. The (LjQ) value to be used is given for each receptor location in Table 6-1.Dp = the external whole body dose due to gamma ray emissions from noble gas radionuclides discharged from the plant site in gaseous effluents, calculated using equation (5.2), in mrem. The AM values that are to be used are given for each receptor location in Table 6-1.6-1 VER29 6-1 VER 29 VEGP ODCM Fo = the occupancy factor for the given location, which is the fraction of the year that one individual MEMBER OF THE PUBLIC is assumed to be present at the receptor location [unitless]. | |||
Values of Fo for each receptor location are included in Table 6-1.6-2 VER 29 VEGP ODCM Table 6-1. Attributes of Member of the Public Receptor Locations Inside the Site Boundary Location: | |||
Visitors Center, SE at 447 meters Age Group: Child Occupancy Factor: 4.57 x 1 0-4 (based on 4 hours per year)Dispersion and Deposition Parameters: | |||
Parameter Ground-Level Mixed-Mode Undepleted (57U', s/m 3 5.93 E-6 7.12 E-7 Depleted (X7Q-, s/m 3 5.58 E-6 6.74 E-7 (DM7Q), m 2 2.28 E-8 5.77 E-9 6-3 VER 29 VEGP ODCM CHAPTER 7 REPORTS 7.1 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT 7.1.1 Requirement for Report In accordance with Technical Specification 5.6.2, the Annual Radiological Environmental Operating Report covering the REMP activities during the previous calendar year shall be submitted before May 15 of each year. (A single report fulfills the requirements for both units.) The material provided shall be consistent with the objectives outlined in section 4.1 and section 7.1.2 of the ODCM, and in Sections IV.B.2, IV.B.3, and IV.C of Appendix I to 10 CFR Part 50.7.1.2 Report Contents The materials specified in the following subsections shall be included in each Annual Radiological Environmental Operating Report: 7.1.2.1 Data The report shall include summarized and tabulated results of all REMP samples required by Table 4-1 taken during the report period, in a format similar to that contained in Table 3 of the Radiological Assessment Branch Technical Position (Reference 19); the results for any additional samples shall also be reported. | |||
In the event that some results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results; the missing data shall be submitted as soon as possible in a supplementary report. The results for naturally-occurring radionuclides not included in plant effluents need not be reported.7.1.2.2 Evaluations Interpretations and analyses of trends of the results shall be included in the report, including the following: (as appropriate) comparisons with preoperational studies, operational controls, and previous environmental reports; and an assessment of any observed impacts of the plant operation on the environment. | |||
If the measured level of radioactivity in an environmental sampling medium exceeding the reporting levels of Table 4-2 is not the result of plant effluents, the condition shall be described as required by Section 4.1.1.2.2. | |||
7.1.2.3 Programmatic Information Also to be included in each report are the following: | |||
a summary description of the REMP; a map(s) of all sampling locations keyed to a table giving distances and 7-1 VER 29 VEGP ODCM directions from a point midway between the centers of the two reactors; the results of land use censuses required by Section 4.1.2; and the results of licensee participation in the Interlaboratory Comparison Program required by Section 4.1.3.7.1.2.4 Descriptions of Program Deviations Discussions of deviations from the established program must be included in each report, as follows: 7.1.2.4.1 If the REMP is not conducted as required in Table 4-1, a description of the reasons for not conducting the program as required, and the plans for preventing a recurrence, must be included in the report.7.1.2.4.2 If the MDCs required by Table 4-3 are not achieved, the contributing factors must be identified and described in the report.7.1.2.4.3 If Interlaboratory Comparison Program analyses are not performed as required by Section 4.1.3, the corrective actions taken to prevent a recurrence must be included in the report.7-2 VER 29 VEGP ODCM 7.2 RADIOACTIVE EFFLUENT RELEASE REPORT 7.2.1 Requirement for Report In accordance with Technical Specification 5.6.3, the Radioactive Effluent Release Report covering the operation of the units during the previous calendar year of operation shall be submitted in accordance with 10 CFR Part 50.36a. (A single submittal may be made for Units 1 and 2. However, the submittal shall specify the releases of radioactive material in liquid and gaseous effluents from each unit and solid radioactive waste from the site.) The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the units. The material provided shall be consistent with the objectives outlined throughout this ODCM and the Process Control Program (PCP) and in conformance with 10 CFR Part 50.36a and Section IV.B.1 of Appendix I to 10 CFR Part 50.7.2.2 Report Contents The materials specified in the following subsections shall be included in each Radioactive Effluent Release Report: 7.2.2.1 Quantities of Radioactive Materials Released The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the units as outlined in NRC Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," Revision 1, June 1974, with liquid and gaseous effluent data summarized on a quarterly basis and solid radioactive waste data summarized on a semiannual basis following the format of Appendix B thereof. Unplanned releases of radioactive materials in gaseous and liquid effluents from the site to UNRESTRICTED AREAS shall be included in the report, tabulated either by quarter or by event. For gamma emitters released in liquid and gaseous effluents, in addition to the principal gamma emitters for which MDCs are specifically established in Table 2-3 and Table 3-3, other peaks which are measurable and identifiable also shall be identified and reported.7.2.2.2 Meteorological Data The report shall include an annual summary of hourly meteorological data collected over the previous year. This annual summary may be either in the form of an hour-by-hour listing of wind speed, wind direction, and atmospheric stability, and precipitation (if measured) on magnetic tape; or in the form of joint frequency distributions of wind speed, wind direction, and atmospheric stability. | |||
In lieu of submission with the Radioactive Effluent Release Report, the licensee has the option of retaining this summary of required meteorological data on site in a file that shall be provided to the NRC upon request.7-3 VER 29 VEGP ODCM 7.2.2.3 Dose Assessments The report shall include an assessment of the radiation doses due to the radioactive liquid and gaseous effluents released from each unit during the previous calendar year.Historical annual average meteorology or the meteorological conditions concurrent with the time of release of radioactive materials in gaseous effluents (as determined by sampling frequency and measurement) shall be used for determining the gaseous pathway doses. This assessment of radiation doses shall be performed in accordance with Sections 2.1.3, 2.4, 3.1.3, 3.1.4, 3.4.2, 3.4.3, 5.1, and 5.2.If a determination is required by Section 5.1.2, the report shall also include an assessment of radiation doses to the likely most exposed MEMBER OF THE PUBLIC from reactor releases and other nearby uranium fuel cycle sources (including doses from primary effluent pathways and direct radiation) for the previous calendar year to show conformance with 40 CFR 190, Environmental Radiation Protection Standards for Nuclear Power Operation; this dose assessment must be performed in accordance with Chapter 5. The report shall also include an assessment of the radiation doses from radioactive liquid and gaseous effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY during the report period; this assessment must be performed in accordance with Chapter 6. All assumptions used in making these assessments (i.e., specific activity, exposure time, and location) shall be included in the report.7.2.2.4 Solid Radwaste Data For each type of solid waste shipped offsite during the report period, the following information shall be included: a. Waste volume, b. Total curie quantity (specify whether determined by measurement of estimate), c. Principal radionuclides (specify whether determined by measurement or estimate), d. Type of waste (e.g., spent resin, compacted dry waste, evaporator bottoms), e. Type of container (e.g., LSA, Type A, Type B, Large Quantity), f. Solidification agent (e.g., cement, urea formaldehyde) and g. Class of solid wastes (as defined by 10 CFR Part 61.)7.2.2.5 Licensee Initiated Document Changes Licensee initiated changes shall be submitted to the Nuclear Regulatory Commission as a part of or concurrent with the Radioactive Effluent Release Report for the period in which any changes were made. Such changes to the ODCM shall be submitted pursuant to Technical Specification 5.5.1. This requirement includes: 7-4 VER 29 VEGP ODCM 7.2.2.5.1 Any changes to the sampling locations in the radiological environmental monitoring program, including any changes made pursuant to Section 4.1.1.2.3. | |||
Documentation of changes made pursuant to Section 4.1.1.2.3 shall include supporting information identifying the cause of the unavailability of samples.7.2.2.5.2 Any changes to dose calculation locations or pathways, including any changes made pursuant to Section 4.1.2.2.2. | |||
7.2.2.6 Descriptions of Program Deviations Discussions of deviations from the established program shall be included in each report, as follows: 7.2.2.6.1 The report shall include deviations from the liquid and gaseous effluent monitoring instrumentation operability requirements included in Sections 2.1.1 and 3.1.1, respectively. | |||
The report shall include an explanation as to why the inoperability of the liquid or gaseous effluent monitoring instrumentation was not corrected within the specified time requirement. | |||
7.2.2.6.2 The report shall include a description of the events leading to liquid holdup tanks or gas storage tanks exceeding the limits of Technical Specification 5.5.12.7.2.2.7 Major Changes to Radioactive Waste Treatment Systems As required by Sections 2.1.5 and 3.1.6, licensee initiated MAJOR CHANGES TO RADIOACTIVE WASTE TREATMENT SYSTEMS (liquid and gaseous) shall be reported to the Nuclear Regulatory Commission in the Radioactive Effluent Release Report covering the period in which the change was reviewed and accepted for implementation. | |||
1 The discussion of each change shall contain: a. A summary of the evaluation that led to the determination that the change could be made in accordance with 10 CFR 50.59;b. Sufficient detailed information to totally support the reason for the change without benefit of additional supplemental information; | |||
: c. A detailed description of the equipment, components, and processes involved and the interfaces with other plant systems;In lieu of inclusion in the Radioactive Effluents Release Report, this same information may be submitted as part of the annual FSAR update.7-5 VER 29 VEGP ODCM d. An evaluation of the change which shows the predicted releases of radioactive materials in liquid and gaseous effluents that differ from those previously predicted in the license applications and amendments thereto;e. An evaluation of the change which shows the expected maximum exposures to individuals in the UNRESTRICTED AREA and to the general population that differ from those previously estimated in the license applications and amendments thereto;f. A comparison of the predicted releases of radioactive materials, in liquid and gaseous effluents, to the actual releases for the period prior to when the changes are to be made;g. An estimate of the exposure to plant operating personnel as a result of the change; and h. Documentation of the fact that the change was reviewed and found acceptable by the PRB.7-6 VER 29 VEGP ODCM 7.3 MONTHLY OPERATING REPORT This ODCM establishes no requirements pertaining to the Monthly Operating Report.7.4 SPECIAL REPORTS Special reports shall be submitted to the Nuclear Regulatory Commission as required by Sections 2.1.3.2, 2.1.4.2, 3.1.3.2, 3.1.4.2, 3.1.5.2, 4.1.1.2.2, and 5.1.2.7-7 VER 29 VEGP ODCM CHAPTER 8 METEOROLOGICAL MODELS The models presented in this chapter are those which were used to compute the specific values of meteorology-related parameters that are referenced throughout this ODCM. These models should also be used whenever it is necessary to calculate values of these parameters for new locations of interest.Note: Although Plant Vogtle has no pure elevated releases, the sections on elevated-mode calculations (8.1.2 and 8.2.2) are included for convenience in calculating mixed-mode values, and to preserve section number compatibility with the ODCMs of the other Southern Company nuclear power plants.8.1 ATMOSPHERIC DISPERSION Atmospheric dispersion may be calculated using the appropriate form of the sector-averaged Gaussian model. Gaseous release elevations may be considered to be either at ground-level, elevated, or mixed-mode. | |||
Facility release elevations for each gaseous release point are as indicated in Table 3-4.8.1.1 Ground-Level Releases Relative concentration calculations for ground-level releases, or for the ground-level portion of mixed-mode releases, shall be made as follows: (X/Q)-= 2.O325-K, rE nk (8.1)N r Xjk IUj Y where: (X/Q)G = the ground-level sector-averaged relative concentration for a given wind direction (sector) and distance (s/mi 3).2.032 = (2/h)1 1 2 divided by the width in radians of a 22.50 sector, which is 0.3927 radians.8 = the plume depletion factor for all radionuclides other than noble gases at a distance r shown in Figure 8-3. For noble gases, the depletion factor is unity. If an undepleted relative concentration is desired, the depletion factor is unity. Only depletion by deposition is considered since depletion by radioactive decay would be of little significance at the distances considered. | |||
Kr = the terrain recirculation factor corresponding to a distance r, taken from Appendix A of Reference 15.8-1 VER 29 VEGP ODCM njk = the number of hours that wind of wind speed class j is directed into the given sector during the time atmospheric stability category k existed.N = the total hours of valid meteorological data recorded throughout the period of interest for all sectors, wind speed classes, and stability categories. | |||
u= the wind speed (mid-point of wind speed class j) at ground level (m/s).r = the distance from release point to location of interest (m).Lzk = the vertical standard deviation of the plume concentration distribution considering the initial dispersion within the building wake, calculated as follows: zk ,.YZzk = the lesser q OR (8.2)ORF3(azk=zk the vertical standard deviation of the plume concentration distribution (m)for a given distance and stability category k as shown in Figure 8-1. The stability category is determined by the vertical temperature gradient AT/Az (0C/100 m).r = 3.1416 b = the maximum height of adjacent plant structure (55 m).8.1.2 Elevated Releases Relative dispersion calculations for elevated releases, or for the elevated portion of mixed-mode releases, shall be made as follows: (X/Q)E _ 2.032KY ,k ujk _(N rO (8.3)8-2 VER 29 VEGP ODCM where: (X/Q)E = the elevated release sector-averaged relative concentration for a given wind direction (sector) and distance (s/m 3).8k= the plume depletion factor for all radionuclides other than noble gases at a distance r for elevated releases, as shown in Figure 8-4, Figure 8-5, and Figure 8-6. For an elevated release, this factor is stability dependent. | |||
For noble gases, the depletion factor is unity. If an undepleted relative concentration is desired, the depletion factor is unity.Only depletion by deposition is considered since depletion by radioactive decay would be of little significance at the distances considered. | |||
njk = the number of hours that wind of wind speed class j is directed into the given sector during the time atmospheric stability category k existed.uj= the wind speed (mid-point of wind speed class j) at the effective release height h (m/s).h = the effective height of the release (m), which is calculated as follows: h = h,, + hpr -h, -c,. (8.4)hv= the height of the release point (m).ht= the maximum terrain height between the release point and the point of interest (m), from Table 8-1.hpr = the additional height due to plume rise (m) which is calculated as follows and limited by hpr(max): 1," 2/3 I/hPr=14 4c{UJ diI/ (8.5)((w'31 -Jd SU )hpr(max)= | |||
the lesser of: OR (8.6)ofj5O.R,- -I/6 d = the inside diameter of the vent (m).8-3 VER 29 VEGP ODCM Cv= the correction for low vent exit velocity (m), which is calculated as follows: 311.5W- 1.d for-W° <1.5 CV OR (8.7)cv={ u)for Wo 1. 5 U Fm = the momentum flux parameter (m 4/s 2), which is calculated as follows: Fm =WO ).d 2 (8.8)S 2)S = the stability parameter: | |||
= 8.75 x 10-4s-2 for -0.5 < AT < 1.5= 1.75 x 10-3 s-2 for 1.5 < AT < 4.0= 2.45 x 10-3 s-2 for AT > 4.0 All other symbols are as previously defined in Section 8.1.1.8.1.3 Mixed-Mode Releases Relative dispersion calculations for mixed-mode releases shall be made as follows: (X/Q)A, = (I -E) .(X/Q)E + E .(X/Q)G (8.9)where: (X/Q)M = the mixed-mode release sector-averaged relative concentration for a given wind direction (sector) and distance (s/mi 3).E = the fraction of hours during which releases are considered as ground-level releases, calculated as follows: 8-4 VER 29 VEGP ODCM 1.0 for W <1.0 uj 0.3-0.06. w wo 5.0 for 1.5<) u 0 for W0 > 5.0 Uj All other symbols are as previously defined.8-5 VER 29 VEGP ODCM 8.2 RELATIVE DEPOSITION Plume depletion may be calculated using the appropriate form of the sector-averaged Gaussian model. Gaseous release elevations may be considered to be either at ground-level, elevated, or mixed-mode. | |||
Facility release elevations for each gaseous release points are as indicated in Table 3-4.8.2.1 Ground-Level Releases Relative deposition calculations for ground-level releases, or for the ground-level portion of mixed-mode releases, shall be made as follows: (DQ) = 2.55D, K Nr k where: (D/Q)G = the ground-level sector-averaged relative deposition for a given wind direction (sector) and distance (m-2).2.55 = the inverse of the number of radians in a 22.5' sector [= (2 7T /16)-1].Dg = the deposition rate at distance r, taken from Figure 8-7 for ground-level releases (m-1).nk= the number of hours in which the wind is directed into the sector of interest, and during which stability category k exists.All other symbols are as defined previously in Section 8.1.8.2.2 Elevated Releases Relative deposition calculations for elevated releases, or for the elevated portion of mixed-mode releases, shall be made as follows: (D/Q)F = 2.55K, Z (n1 Dk (8.12)Nr k where: (D/Q)E = the elevated-plume sector-averaged relative deposition for a given wind direction (sector) and distance (m-2).Dek = the elevated plume deposition rate at distance r, taken from Figure 8-8, Figure 8-9, or Figure 8-10, as appropriate to the plume effective release height h defined in Section 8.1.2, for stability class k (m-1).All other symbols are as defined previously. | |||
8-6 VER 29 VEGP ODCM 8.2.3 Mixed-Mode Releases Relative deposition calculations for mixed-mode releases shall be made as follows: (D/Q)0 = (1- E).(D/Q)E | |||
+ E.(D/Q)G (8.13)where: (D/Q)M = the mixed-mode release sector-averaged relative deposition for a given wind direction (sector) and distance (m-2).E = the fraction of hours during which releases are considered as ground-level releases, defined in Section 8.1.3.All other symbols are as previously defined.8.3 ELEVATED PLUME DOSE FACTORS These factors are not required in effluent dose calculations for VEGP.8-7 VER 29 VEGP ODCM Table 8-1. Terrain Elevation Above Plant Site Grade Dist. NENNESNE ENE EWESE TSW W SNSSWW NNW (m) 1 500 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 8.7 5.7 1.4 5.8 5.7 3.5 1,000 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 16.7 13.4 3.3 10.4 11.8 6.8 1,500 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 21.7 18.6 7.3 12.2 14.3 7.3 2,000 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 21.7 18.6 7.3 12.2 14.3 7.3 2,500 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 21.7 18.6 7.3 12.2 14.3 7.3 3,000 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 23.7 18.6 7.3 12.2 14.3 7.3 3,500 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 24.4 18.6 7.3 12.2 16.9 7.3 4,000 0.0 0.0 0.0 0.0 0.0 0.0 4.5 0.0 0.0 4.7 24.4 18.6 7.3 12.2 16.9 7.3 5,000 0.0 0.0 0.0 0.0 0.0 0.0 11.1 0.0 0.0 4.7 24.7 18.6 7.3 12.2 16.9 7.3 6,000 0.0 0.0 0.0 0.0 0.0 0.0 11.1 0.0 0.0 4.7 26.8 18.6 7.3 12.2 16.9 7.3 7,000 0.0 0.0 0.0 7.8 0.0 0.0 11.1 0.0 3.6 4.7 26.8 18.6 7.3 12.2 16.9 7.3 8,000 0.0 0.0 21.1 13.9 0.0 0.0 11.8 0.0 14.6 4.7 26.8 18.6 7.3 12.2 16.9 7.3 9,000 0.0 0.0 24.4 14.6 0.0 0.0 12.7 7.1 14.6 5.1 26.8 18.6 7.3 12.2 16.9 7.3 10,000 0.0 10.2 24.4 20.2 0.0 0.0 17.1 17.0 14.6 6.8 26.8 18.6 7.3 12.2 16.9 7.3 12,000 0.0 15.9 26.8 20.2 0.0 0.0 17.1 19.5 14.6 6.8 34.1 28.9 13.4 12.2 16.9 7.3 14,000 0.0 15.9 26.8 20.2 0.0 0.0 17.1 19.5 14.6 6.8 34.1 28.9 13.4 16.5 19.7 7.3 16,000 0.0 15.9 26.8 21.7 13.2 0.0 17.1 19.5 14.6 6.8 34.1 28.9 13.4 16.5 25.7 7.3 Data in this table are obtained from Reference 11.8-8 VER 29 VEGPODCM I UI.: ".'.-f--' I A' I I I I-1, N 0 V -/0CI I-01 E "1-01 L., 00 1 40 10'0 0.1 1 10 PLUME TRAVEL DISTANCE (KILOMETERS) 100 Range of Vertical Range of Vertical Category Temperature Gradient Temperature Gradient (0 C/100 m) (°F/100 ft)A AT/AZ < -1.9 AT/AZ < -1.0 B -1.9 s AT/AZ < -1.7 -1.0 s AT/AZ < -0.9 C -1.7 s AT/AZ < -1.5 -0.9 s AT/AZ < -0.8 D -1.5 s AT/AZ < -0.5 -0.8 s AT/AZ < -0.3 E -0.5 s AT/AZ < 1.5 -0.3 s AT/AZ < 0.8 F 1.5 s AT/AZ < 4.0 0.8 s AT/AZ < 2.2 G 4.0 s AT/AZ 2.2 s AT/AZ mTh caranh is reproduced from Reference 5 (Figure 1)5 Figure 8-1. Vertical Standard Deviation of Material in a Plume (crz)8-9 VER 29 VEGP ODCM 8-10 VER 29 VEGP ODCM This figure intentionally left blank.Refer to the definition for Kr (terrain recirculation factor) in section 8.1.1 for applicable plant data.Figure 8-2. Terrain Recirculation Factor (Kr)8-11 VER 29 VEGPODCM z w 6 t=a: 1.0 0.9 0.7 0.6 0.4 0.2 0.1 0.1 1.0 1 0 PLUME TRAVEL DISTANCE (KILOMETERS) 100.0 200.0 This graph is reproduced from Reference 5 (Figure 2).Figure 8-3. Plume Depletion Effect for Ground Level Releases 8-12 VER 29 VEGPODCM 1.0 0.1I£0.7 I ,o, c 0.1 0.4 C U. 0".3 0.2 0.1 0.1 1.0 10.0 PLUMETRAVEL DISTANCE (KILOMETERS) 100.0' IOQ.0 This graph is reproduced from Reference 5 {Figure 3)Fiaure 8-4. Plume Depletion Effect for 30-Meter Releases 8-13 VER 29 VEGPODCM 1.0 0.8 r-: -::: 1:..STABLE-r-t-- J -ý EUTR.A.L'0.8'g- 0.7 z o.e 0.20.3 0.1 1.0 10.0 PLUMETRAVEL DISTANCE (KILOMETERSJ This graph is reproduced from Reference 5 (Figure 4).8-14 VER 29 VEGPODCM 100.0 200.0 Figure 8-5. Plume Depletion Effect for 60-Meter Releases 8-15 VER 29 VEGPODCM 1.0 S.,-I iV 0.8 0.7 i Z 0.1 C It 0.5 Q= OA ac 0.3--o-0 NEUTRAL CDJ _UNSTABLE STABLE CE.F,G) lA.B.C)IR L I I. ) I I (FRACTI{N -EIIJN i 1.f i L I,,I G.2 0.1 0.1 1.0 10.0 PLUME.TRAVEL DISTANCE CKILOMETERSJ 100.0 200.0 This graph is reproduced from Reference 5 (Figure 5).8-16 VER 29 VEGPODCM---I ~-*r--~I I I lo-w a: w!: V-- u I II I l III a: zo to-ill A.W C w a: Io-7 0.1 1.0 10.0 PLUME TRAVEL DISTANCE (KILOMETERS) 100.0 200.0 This graph is reproduced from Reference 5 (Figure 6)Figure 8-6. Plume Depletion Effect for 100-Meter Releases 8-17 VER 29 VEGP ODCM Figure 8-7. Relative Deposition for Ground-Level Releases 8-18 VER 29 VEGPODCM 1o-4 " t' I I I 11 ic -j IH' I ... I I I :E a: '"' I NEUTRAL z NEUTRALUME thi g a-5 is rc 7..en 8 e D I fr0MeR 0 ' i i: a: JrAL(EFG 10-6 -" l I I : :: :F: 0.1 1.0 10.0 100.0 200.0 PLUME TRAVEL DISTANCE (KILOM4ETERS) | |||
This graph is reproduced from Reference 5 (Figure 7).Figure 8-8. Relative Deposition for 30-Meter Releases 8-19 VER 29 VEGPODCM Io-5 w w a::.w a: z Io-6 Io-7.,STABLE EFG i! I FL J I 0.1 1.0 I0.Ot 100.0- 200.0 PLUME TRAVEL DISTANCE (KILOMETERS) | |||
This graph is reproduced from Reference 5 [Figure 8).8-20 VER 29 VEGPODCM I-igure b-9. Relative IUeposition tor (bu-Meter Releases 8-21 VER 29 VEGPODCM 10 lo-s%V a: C(z III i--w C w a: 10-6 III UNSTABLE (A,B C1 if w STABLE (E,FG)PLUME TRAVEL DISTANCE (KILOMETERS) 10-8 This graph is reproduced from Reference 5 (Figure 9).Figure 8-10. Relative Deposition for 100-Meter (or Greater) Releases 8-22 VER 29 VEGP ODCM CHAPTER 9 METHODS AND PARAMETERS FOR CALCULATION OF GASEOUS EFFLUENT PATHWAY DOSE FACTORS, Raipj 9.1 INHALATION PATHWAY FACTOR For the inhalation pathway, Raipj in (mrem/y) per ( iCi/m 3) is calculated as follows (Reference 1, Section 5.3.1.1): Raipj = K 1 * (BR)a .(DFA)a~j (9.1)where: K 1 = the units conversion factor: 106 pCi/ltCi.(BR)a = the breathing rate of receptor age group a, in m 3/y, from Table 9-5.(DFA)aij = the inhalation dose factor for receptor age group a, radionuclide i, and organ j, in mrem/pCi, from Table 9-7 through Table 9-10.9-1 VER 29 VEGP ODCM 9.2 GROUND PLANE PATHWAY FACTOR For the ground plane external exposure pathway, Raipj in (m 2.mrem/y) per (ýtCi/s)is calculated as follows (Reference 1, Section 5.3.1.2): Rapj= K, .-K2 .(SHF). (DFG j1-e') (9.2)where: K 1 = the units conversion factor: 106 pCi/pCi.K 2 = the units conversion factor: 8760 h/y.(SHF) = the shielding factor due to structure (dimensionless). | |||
The value used for (SHF) is 0.7, from (Reference 3, Table E-15).(DFG)ij = the ground plane dose factor for radionuclide i and organ j, in (mrem/h) per (pCi/m 2), from Table 9-15. Dose factors are the same for all age groups, and those for the total body also apply to all organs other than skin.= the radioactive decay constant for radionuclide i, in s-1. Values of Xi used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.t = the exposure time, in s. The value used fort is 4.73 x 10 8 s (= 15 y), from (Reference 1, Section 5.3.1.2).9-2 VER 29 VEGP ODCM 9.3 GARDEN VEGETATION PATHWAY FACTOR For radionuclides other than tritium in the garden vegetation consumption pathway, Rapj in (m 2.mrem/y) per (pICi/s) is calculated as follows (Reference 1, Section 5.3.1.5): R,,,pj = K, .MA (DFLT),, (UfLe-' + e (9.3)where: K 1 = the units conversion factor: 106 pCi/lCi.r = the fraction of deposited activity retained on the edible parts of garden vegetation (dimensionless). | |||
The value used for r is 1.0 for radioiodines and 0.2 for particulates, from (Reference 3, Table E-1).Yv the areal density (agricultural productivity) of growing leafy garden vegetation, in kg/M 2 , from Table 9-1.= the radioactive decay constant for radionuclide i, in s-1. Values of Xq used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.x = the rate constant for removal of activity on leaf and plant surfaces by weathering, in s-1, from Table 9-1.(DFL)aij -the ingestion dose factor for receptor age group a, radionuclide i, and organ j, in mrem/pCi, from Table 9-11 through Table 9-14.UaL the consumption rate of fresh leafy garden vegetation by a receptor in age group a, in kg/y, from Table 9-5.Uas = the consumption rate of stored garden vegetation by a receptor in age group a, in kg/y, from Table 9-5.fL = the fraction of the annual intake of fresh leafy garden vegetation that is grown locally (dimensionless), from Table 9-1.fg = the fraction of the annual intake of stored garden vegetation that is grown locally (dimensionless), from Table 9-1.tL = the average time between harvest of fresh leafy garden 9-3 VER 29 VEGP ODCM vegetation and its consumption, in s, from Table 9-1.thv = the average time between harvest of stored garden vegetation and its consumption, in s, from Table 9-1.For tritium in the garden vegetation consumption pathway, Raipj in (mrem/y) per (pLCi/i 3) is calculated as follows (Reference 1, Section 5.3.1.5), based on the concentration in air rather than deposition onto the ground: (0.5,)Ra,rj = K, .K 3* (DFL),I -*(U,.flI + Uasf, )O. 75. -- 1 (9.4)~H where: K 3 = = the units conversion factor: 10 3 g/kg.H = = the absolute humidity of atmospheric air, in g/m 3 , from Table 9-1.0.75 = the fraction of the mass of total garden vegetation that is water= (dimensionless). | |||
0.5 = = the ratio of the specific activity of tritium in garden vegetation water to that in atmospheric water (dimensionless). | |||
and other parameters are as defined above.9-4 VER 29 VEGP ODCM Table 9-1.Miscellaneous Parameters for the Garden Vegetation Pathway The following parameter values are for use in calculating Raipj for the garden vegetation pathway only. The terms themselves are defined in section 9.3.Parameter Value Reference Yv 2.0 kg/M 2 Ref. 3, Table E-15 Xw 5.73 x 10-7s 1 Ref. 1, page 33 (14-day half-life) fL 1.0 Ref. 1, page 36 f9 0.76 Ref. 1, page 33 tL 8.6 x 104S Ref. 3, Table E-15 (1 day)thy 5.18 x 106 S Ref. 3, Table E-15 (60 days)H 8 g/m 3 Ref. 3 9-5 VER 29 VEGP ODCM 9.4 GRASS-COW-MILK PATHWAY FACTOR For radionuclides other than tritium in the grass-cow-milk pathway, Raipj in (m 2.mrem/y) per (gCi/s) is calculated as follows (Reference 1, Section 5.3.1.3): R,,,m = K, r .Q p. .U,,p .F,,, .(DFL),,,j | |||
.ýfpf, + (I*fm -' (9.6)Y Y (+) ., where: K 1 = the units conversion factor: 106 pCi/gCi.r = the fraction of deposited activity retained on the edible parts of vegetation (dimensionless). | |||
The value used for r is 1.0 for radioiodines and 0.2 for particulates, from (Reference 3, Table E-1).x = the radioactive decay constant for radionuclide i, in s-1. Values of Xj used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.w = the rate constant for removal of activity on leaf and plant surfaces by weathering, in s-1, from Table 9-2.QF = the cow's consumption rate of feed, in kg/d, from Table 9-2.Uap the consumption rate of cow milk by a receptor in age group a, in L/y, from Table 9-5.Fmi the stable element transfer coefficient applicable to radionuclide i, for cow's milk, in d/L, from Table 9-6.(DFL)aij = the ingestion dose factor for receptor age group a, radionuclide i, and organ j, in mrem/pCi, from Table 9-11 through Table 9-14.fp the fraction of the year that the cow is on pasture (dimensionless), from Table 9-2.fs the fraction of the cow's feed that is pasture grass while the cow is on pasture (dimensionless), from Table 9-2.Y1 = the areal density (agricultural productivity) of growing pasture feed grass, in kg/mi, from Table 9-2.9-6 VER 29 VEGP ODCM Y = the areal density (agricultural productivity) of growing stored feed, in kg/M 2 , from Table 9-2.thin = the transport time from harvest of stored feed to its consumption by the cow, in s, from Table 9-2.tf = the transport time from consumption of feed by the cow, to consumption of milk by the receptor, in s, from Table 9-2.For tritium in the grass-cow-milk pathway, Raipj in (mrem/y) per (ltCi/m 3) is calculated as follows (Reference 1, Section 5.3.1.5), based on the concentration in air rather than deposition onto the ground: R,,Pi=K, K 3 .QF .Up ' F,, .(DFL)ao .0. 75.1 (05) (9.6)where: K3 = the units conversion factor: 103 g/kg.H = the absolute humidity of atmospheric air, in g/m 3 , from Table 9-2.0.75 = the fraction of the mass of total vegetation that is water (dimensionless). | |||
0.5 = the ratio of the specific activity of tritium in vegetation water to that in atmospheric water (dimensionless). | |||
and other parameters are as defined above.9-7 VER 29 VEGP ODCM Table 9-2.Miscellaneous Parameters for the Grass-Cow-Milk Pathway The following parameter values are for use in calculating only. The terms themselves are defined in section 9.4.Raipj for the grass-cow-milk pathway Parameter Value Reference 5.73 x 10-7 s-1 Ref. 1, page 33 (14-day half-life) | |||
QF 50 kg/d Ref. 3, Table E-3 fp 1.0 Ref. 1, page 33 fs 1.0 Ref. 1, page 33 YP 0.7 kg/M 2 Ref. 3, Table E-15 YS 2.0 kg/M 2 Ref. 3, Table E-15 thin 7.78 x 106 S Ref. 3, Table E-15 (90 days)tf 1.73 x 10s Ref. 3, Table E-15 (2 days)H 8 g/m 3 Ref. 3 9-8 VER 29 VEGP ODCM 9.5 GRASS-GOAT-MILK PATHWAY FACTOR For radionuclides other than tritium in the grass-goat-milk pathway, Rapj in (m 2.mrem/y) per ([tCi/s) is calculated as follows (Reference 1, Section 5.3.1.3): Fff(1-f~fj)-'''' | |||
Ra=pi K, + r F .F,,, (DFLL. i + (Pf + (97)where: K 1 = the units conversion factor: 106 pCi/pCi.r = the fraction of deposited activity retained on the edible parts of vegetation (dimensionless). | |||
The value used for r is 1.0 for radioiodines and 0.2 for particulates, from (Reference 3, Table E-1).= the radioactive decay constant for radionuclide i, in s-1.Values of Xi used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.the rate constant for removal of activity on leaf and plant surfaces by weathering, in s-1, from Table 9-3.QF = the goat's consumption rate of feed, in kg/d, from Table 9-3.Uap = the consumption rate of goat milk by a receptor in age group a, in L/y, from Table 9-5.Fmi = the stable element transfer coefficient applicable to radionuclide i, for goat's milk, in d/L, from Table 9-6.(DFL)aij = the ingestion dose factor for receptor age group a, radionuclide i, and organ j, in mrem/pCi, from Table 9-11 through Table 9-14.fp = the fraction of the year that the goat is on pasture (dimensionless), from Table 9-3.f, = the fraction of the goat's feed that is pasture grass while the goat is on pasture (dimensionless), from Table 9-3.Yp = the areal density (agricultural productivity) of growing pasture feed grass, in kg/m , from Table 9-3.9-9 VER 29 VEGP ODCM Ys = the areal density (agricultural productivity) of growing stored feed, in kg/M 2 , from Table 9-3.thm = the transport time from harvest of stored feed to its consumption by the goat, in s, from Table 9-3.tf = the transport time from consumption of feed by the goat, to consumption of milk by the receptor, in s, from Table 9-3.For tritium in the grass-goat-milk pathway, Raipj in (mrem/y) per (AjCi/m 3) is calculated as follows (Reference 1, Section 5.3.1.5), based on the concentration in air rather than deposition onto the ground: Ra,pj = K. | |||
* K 3 .Q, .'U .Fm, .(DFL),j .0. 75. (05) (9.8)where: K 3 = the units conversion factor: 10 3 g/kg.H = the absolute humidity of atmospheric air, in g/m 3 , from Table 9-3.0.75 = the fraction of the mass of total vegetation that is water (dimensionless). | |||
0.5 = the ratio of the specific activity of tritium in vegetation water to that in atmospheric water (dimensionless). | |||
and other parameters are as defined above.9-10 VER 29 VEGP ODCM Table 9-3.Miscellaneous Parameters for the Grass-Goat-Milk Pathway The following parameter values are for use in calculating Raipj for the grass-goat-milk pathway only. The terms themselves are defined in section 9-5.Parameter Value Reference 5.73 x 107 s-I Ref. 1, page 33 (14-day half-life) | |||
QF 6 kg/d Ref. 3, Table E-3 fp 1.0 Ref. 1, page 33 fs 1.0 Ref. 1, page 33 Yp 0.7 kg/M 2 Ref. 3, Table E-15 Ys 2.0 kg/M 2 Ref. 3, Table E-15 thin 7.78 x 106 S Ref. 3, Table E-15 (90 days)tf 1.73 x 10 5 s Ref. 3, Table E-15 (2 days)H 8 g/m 3 Ref. 3 9-11 VER 29 VEGP ODCM 9.6 GRASS-COW-MEAT PATHWAY FACTOR For radionuclides other than tritium in the grass-cow-meat pathway, Raipj in (m 2-mrem/y) per (.Ci/s) is calculated as follows (Reference 1, Section 5.3.1.4): RaTV, r .FK 1.QL -,f,)*Uap | |||
* 1 je- + (9.9)+ L11r: where: K 1 = the units conversion factor: 106 pCi/pCi.r = the fraction of deposited activity retained on the edible parts of vegetation (dimensionless). | |||
The value used for r is 1.0 for radioiodines and 0.2 for particulates, from (Reference 3, Table E-1).i= the radioactive decay constant for radionuclide i, in s-1.Values of ki used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.x= the rate constant for removal of activity on leaf and plant surfaces by weathering, in s-1, from Table 9-4.QF = the cow's consumption rate of feed, in kg/d, from Table 9-4.Uap " the consumption rate of meat by a receptor in age group a, in kg/y, from Table 9-5.F,= the stable element transfer coefficient applicable to radionuclide i, for meat, in d/kg, from Table 9-6.(DFL)aij = the ingestion dose factor for receptor age group a, radionuclide i, and organ j, in mrem/pCi, from Table 9-11 through Table 9-14.fp = the fraction of the year that the cow is on pasture (dimensionless), from Table 9-4.fs = the fraction of the cow's feed that is pasture grass while the cow is on pasture (dimensionless), from Table 9-4.9-12 VER 29 VEGP ODCM Yp = the areal density (agricultural productivity) of growing pasture feed grass, in kg/mr, from Table 9-4.Ys = the areal density (agricultural productivity) of growing stored feed, in kg/M 2 , from Table 9-4.thrn = the transport time from harvest of stored feed to its consumption by the cow, in s, from Table 9-4.tf = the transport time from consumption of feed by the cow, to consumption of meat by the receptor, in s, from Table 9-4.For tritium in the grass-cow-meat pathway, Raapj in (mrem/y) per (lLCi/m 3) is calculated as follows (Reference 1, Section 5.3.1.4), based on the concentration in air rather than deposition onto the ground: Ra,j =K, .K 3 "QF U,,p .Ff .(DFL), (0.75.( 59.10)where: K 3 = the units conversion factor: 103 g/kg.H = the absolute humidity of atmospheric air, in g/m 3 , from Table 9-4.0.75 = the fraction of the mass of total vegetation that is water (dimensionless). | |||
0.5 = the ratio of the specific activity of tritium in vegetation water to that in atmospheric water (dimensionless). | |||
and other parameters are as defined above.9-13 VER 29 VEGP ODCM Table 9-4.Miscellaneous Parameters for the Grass-Cow-Meat Pathway The following parameter values are for use in calculating Rapj for the grass-cow-meat pathway only. The terms themselves are defined in section 9-6.Parameter Value Reference xw 5.73 x 10-7 s-1 Ref. 1, page 33 (14-day half-life) | |||
QF 50 kg/d Ref. 3, Table E-3 fp 1.0 Ref. 1, page 33 f. 1.0 Ref. 1, page 33 Yp 0.7 kg/M 2 Ref. 3, Table E-15 YS 2.0 kg/M 2 Ref. 3, Table E-15 thin 7.78 x 106 s Ref. 3, Table E-15 (90 days)tf 1.73 x10 6 s Ref. 3, Table E-15 (20 days)H 8 g/m 3 Ref. 3 9-14 VER 29 VEGP ODCM Table 9-5. Individual Usage Factors Receptor Age Group Usage Factor Infant Child Teenager Adult Milk Consumption Rate, Uap 330 330 400 310 (L/y)Meat Consumption Rate, Uap 0 41 65 110 (kg/y)Fresh Leafy Garden Vegetation 0 26 42 64 Consumption Rate, UaL (kg/y)Stored Garden Vegetation 0 520 630 520 Consumption Rate, Uas (kg/y)Breathing Rate, (BR), 1400 3700 8000 8000 (m 3/y) I I All values are from Reference 3, Table E-5.9-15 VER 29 VEGP ODCM Table 9-6.Stable Element Transfer Data Cow Milk Goat Milk Meat Element Fm (d/L)" Fm (d/L)÷ Ff (d/kg)*H 1.0 E-02 1.7 E-01 1.2 E-02 C 1.2 E-02 1.0 E-01 3.1 E-02 Na 4.0 E-02 4.0 E-02 3.0 E-02 P 2.5 E-02 2.5 E-01 4.6 E-02 Cr 2.2 E-03 2.2 E-03 2.4 E-03 Mn 2.5 E-04 2.5 E-04 8.0 E-04 Fe 1.2 E-03 1.3 E-04 4.0 E-02 Co 1.0 E-03 1.0 E-03 1.3 E-02 Ni 6.7 E-03 6.7 E-03 5.3 E-02 Cu 1.4 E-02 1.3 E-02 8.0 E-03 Zn 3.9 E-02 3.9 E-02 3.0 E-02 Br 5.0 E-02 5.0 E-02 2.6 E-02 Rb 3.0 E-02 3.0 E-02 3.1 E-02 Sr 8.0 E-04 1.4 E-02 6.0 E-04 Y 1.0 E-05 1.0 E-05 4.6 E-03 Zr 5.0 E-06 5.0 E-06 3.4 E-02 Nb 2.5 E-03 2.5 E-03 2.8 E-01 Mo 7.5 E-03 7.5 E-03 8.0 E-03 Tc 2.5 E-02 2.5 E-02 4.0 E-01 Ru 1.0 E-06 1.0 E-06 4.0 E-01 Rh 1.0 E-02 1.0 E-02 1.5 E-03 Ag 5.0 E-02 5.0 E-02 1.7 E-02 Sb 1.5 E-03 1.5 E-03 4.0 E-03 Te 1.0 E-03 1.0 E-03 7.7 E-02 1 6.0 E-03 6.0 E-02 2.9 E-03 Cs 1.2 E-02 3.0 E-01 4.0 E-03 Ba 4.0 E-04 4.0 E-04 3.2 E-03 La 5.0 E-06 5.0 E-06 2.0 E-04 Ce 1.0 E-04 1.0 E-04 1.2 E-03 Pr 5.0 E-06 5.0 E-06 4.7 E-03 Nd 5.0 E-06 5.0 E-06 3.3 E-03 W 5.0 E-04 5.0 E-04 1.3 E-03 Np 5.0 E-06 5.0 E-06 2.0 E-04* -Values from Reference 3 for Br and Sb.(Table E-1) except as follows: Reference 2 (Table C-5)+ -Values from Reference 3, Table E-2 for H, C, P, Fe, Cu, Sr, I, and Cs in goat milk, and Table E-1 for all other elements in cow milk, except as follows: Reference 2 (Table C-5) for Br and Sb in cow milk.9-16 VER 29 VEGP ODCM Table 9-7. Inhalation Dose Factors for the Infant Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI H-3 No Data 4.62E-07 4.62E-07 4.62E-07 4.62E-07 4.62E-07 4.62E-07 C-14 1.89E-05 3.79E-06 3.79E-06 3.79E-06 3.79E-06 3.79E-06 3.79E-06 Na-24 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 P-32 1.45E-03 8.03E-05 5.53E-05 No Data No Data No Data 1.15E-05 Cr-51 No Data No Data 6.39E-08 4.11E-08 9.45E-09 9.17E-06 2.55E-07 Mn-54 No Data 1.81E-05 3.56E-06 No Data 3.56E-06 7.14E-04 5.04E-06 Mn-56 No Data 1.1OE-09 1.58E-10 No Data 7.86E-10 8.95E-06 5.12E-05 Fe-55 1.41 E-05 8.39E-06 2.38E-06 No Data No Data 6.21 E-05 7.82E-07 Fe-59 9.69E-06 1.68E-05 6.77E-06 No Data No Data 7.25E-04 1.77E-05 Co-58 No Data 8.71 E-07 1.30E-06 No Data No Data 5.55E-04 7.95E-06 Co-60 No Data 5.73E-06 8.41E-06 No Data No Data 3.22E-03 2.28E-05 Ni-63 2.42E-04 1.46E-05 8.29E-06 No Data No Data 1.49E-04 1.73E-06 Ni-65 1.71E-09 2.03E-10 8.79E-11 No Data No Data 5.80E-06 3.58E-05 Cu-64 No Data 1.34E-09 5.53E-10 No Data 2.84E-09 6.64E-06 1.07E-05 Zn-65 1.38E-05 4.47E-05 2.22E-05 No Data 2.32E-05 4.62E-04 3.67E-05 Zn-69 3.85E-11 6.91E-11 5.13E-12 No Data 2.87E-11 1.05E-06 9.44E-06 Br-83 No Data No Data 2.72E-07 No Data No Data No Data No Data Br-84 No Data No Data 2.86E-07 No Data No Data No Data No Data Br-85 No Data No Data 1.46E-08 No Data No Data No Data No Data Rb-86 No Data 1.36E-04 6.30E-05 No Data No Data No Data 2.17E-06 Rb-88 No Data 3.98E-07 2.05E-07 No Data No Data No Data 2.42E-07 Rb-89 No Data 2.29E-07 1.47E-07 No Data No Data No Data 4.87E-08 Sr-89 2.84E-04 No Data 8.15E-06 No Data No Data 1.45E-03 4.57E-05 Sr-90 2.92E-02 No Data 1.85E-03 No Data No Data 8.03E-03 9.36E-05 Sr-91 6.83E-08 No Data 2.47E-09 No Data No Data 3.76E-05 5.24E-05 All values are in (mrem/pCi inhaled). | |||
They are obtained from Reference 3 (Table E-10). Neither Reference 2 nor Reference 3 contains data for Rh-105, Sb-124, or Sb-125.9-17 VER 29 VEGP ODCM 9-18 VER 29 VEGP ODCM Table 9-7 (contd). Inhalation Dose Factors for the Infant Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 7.50E-09 No Data 2.79E-10 No Data No Data 1.70E-05 1.OOE-04 Y-90 2.35E-06 No Data 6.30E-08 No Data No Data 1.92E-04 7.43E-05 Y-91m 2.91E-10 No Data 9.90E-12 No Data No Data 1.99E-06 1.68E-06 Y-91 Y-92 Y-93 4.20E-04 1.17E-08 1.07E-07 No Data No Data No Data 1.12E-05 3.29E-10 2.91 E-09 No Data No Data No Data No Data No Data No Data 1.75E-03 1.75E-05 5.46E-05 5.02E-05 9.04E-05 1.19E-04 Zr-95 8.24E-05 1.99E-05 1.45E-05 No Data 2.22E-05 1.25E-03 1.55E-05 Zr-97 1.07E-07 1.83E-08 8.36E-09 No Data 1.85E-08 7.88E-05 1.OOE-04 Nb-95 1.12E-05 4.59E-06 2.70E-06 No Data 3.37E-06 3.42E-04 9.05E-06 Mo-99 No Data 1.18E-07 2.31E-08 No Data 1.89E-07 9.63E-05 3.48E-05 Tc-99m 9.98E-13 2.06E-12 2.66E-11 No Data 2.22E-11 5.79E-07 1.45E-06 Tc-101 4.65E-14 5.88E-14 5.80E-13 No Data 6.99E-13 4.17E-07 6.03E-07 Ru-103 1.44E-06 No Data 4.85E-07 No Data 3.03E-06 3.94E-04 1.15E-05 Ru-105 8.74E-10 No Data 2.93E-10 No Data 6.42E-10 1.12E-05 3.46E-05 Ru-106 6.20E-05 No Data 7.77E-06 No Data 7.61E-05 8.26E-03 1.17E-04 Rh-105 No Data No Data No Data No Data No Data No Data No Data Ag-110m 7.13E-06 5.16E-06 3.57E-06 No Data 7.80E-06 2.62E-03 2.36E-05 Sb-124 No Data No Data No Data No Data No Data No Data No Data Sb-125 No Data No Data No Data No Data No Data No Data No Data Te-125m 3.40E-06 1.42E-06 4.70E-07 1.16E-06 No Data 3.19E-04 9.22E-06 Te-127m 1.19E-05 4.93E-06 1.48E-06 3.48E-06 2.68E-05 9.37E-04 1.95E-05 Te-127 1.59E-09 6.81E-10 3.49E-10 1.32E-09 3.47E-09 7.39E-06 1.74E-05 Te-129m 1.01E-05 4.35E-06 1.59E-06 3.91E-06 2.27E-05 1.20E-03 4.93E-05 Te-129 5.63E-11 2.48E-11 1.34E-11 4.82E-11 1.25E-10 2.14E-06 1.88E-05 Te-131rm 7.62E-08 3.93E-08 2.59E-08 6.38E-08 1.89E-07 1.42E-04 8.51E-05 Te-131 1.24E-11 5.87E-12 3.57E-12 1.13E-11 2.85E-11 1.47E-06 5.87E-06 9-19 VER 29 VEGP ODCM Table 9-7 (contd). Inhalation Dose Factors for the Infant Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 2.66E-07 1.69E-07 1.26E-07 1.99E-07 7.39E-07 2.43E-04 3.15E-05 1-130 4.54E-06 9.91E-06 3.98E-06 1.14E-03 1.09E-05 No Data 1.42E-06 1-131 2.71E-05 3.17E-05 1.40E-05 1.06E-02 3.70E-05 No Data 7.56E-07 1-132 1.21E-06 2.53E-06 8.99E-07 1.21E-04 2.82E-06 No Data 1.36E-06 1-133 9.46E-06 1.37E-05 4.OOE-06 2.54E-03 1.60E-05 No Data 1.54E-06 1-134 6.58E-07 1.34E-06 4.75E-07 3.18E-05 1.49E-06 No Data 9.21E-07 1-135 2.76E-06 5.43E-06 1.98E-06 4.97E-04 6.05E-06 No Data 1.31E-06 Cs-134 2.83E-04 5.02E-04 5.32E-05 No Data 1.36E-04 5.69E-05 9.53E-07 Cs-136 3.45E-05 9.61E-05 3.78E-05 No Data 4.03E-05 8.40E-06 1.02E-06 Cs-137 3.92E-04 4.37E-04 3.25E-05 No Data 1.23E-04 5.09E-05 9.53E-07 Cs-138 3.61E-07 5.58E-07 2.84E-07 No Data 2.93E-07 4.67E-08 6.26E-07 Ba-139 1.06E-09 7.03E-13 3.07E-11 No Data 4.23E-13 4.25E-06 3.64E-05 Ba-140 4.OOE-05 4.OOE-08 2.07E-06 No Data 9.59E-09 1.14E-03 2.74E-05 Ba-141 1.12E-10 7.70E-14 3.55E-12 No Data 4.64E-14 2.12E-06 3.39E-06 Ba-142 2.84E-11 2.36E-14 1.40E-12 No Data 1.36E-14 1.11E-06 4.95E-07 La-140 3.61E-07 1.43E-07 3.68E-08 No Data No Data 1.20E-04 6.06E-05 La-142 7.36E-10 2.69E-10 6.46E-11 No Data No Data 5.87E-06 4.25E-05 Ce-141 1.98E-05 1.19E-05 1.42E-06 No Data 3.75E-06 3.69E-04 1.54E-05 Ce-143 2.09E-07 1.38E-07 1.58E-08 No Data 4.03E-08 8.30E-05 3.55E-05 Ce-144 2.28E-03 8.65E-04 1.26E-04 No Data 3.84E-04 7.03E-03 1.06E-04 Pr-143 1.OOE-05 3.74E-06 4.99E-07 No Data 1.41E-06 3.09E-04 2.66E-05 Pr-144 3.42E-11 1.32E-11 1.72E-12 No Data 4.80E-12 1.15E-06 3.06E-06 Nd-147 5.67E-06 5.81E-06 3.57E-07 No Data 2.25E-06 2.30E-04 2.23E-05 W-187 9.26E-09 6.44E-09 2.23E-09 No Data No Data 2.83E-05 2.54E-05 Np-239 2.65E-07 2.37E-08 1.34E-08 No Data 4.73E-08 4.25E-05 1.78E-05 9-20 VER 29 VEGP ODCM Table 9-8.Inhalation Dose Factors for the Child Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 No Data 3.04E-07 3.04E-07 3.04E-07 3.04E-07 3.04E-07 3.04E-07 C-14 9.70E-06 1.82E-06 1.82E-06 1.82E-06 1.82E-06 1.82E-06 1.82E-06 Na-24 4.35E-06 4.35E-06 4.35E-06 4.35E-06 4.35E-06 4.35E-06 4.35E-06 P-32 7.04E-04 3.09E-05 2.67E-05 No Data No Data No Data 1.14E-05 Cr-51 No Data No Data 4.17E-08 2.31E-08 6.57E-09 4.59E-06 2.93E-07 Mn-54 No Data 1.16E-05 2.57E-06 No Data 2.71E-06 4.26E-04 6.19E-06 Mn-56 No Data 4.48E-10 8.43E-11 No Data 4.52E-10 3.55E-06 3.33E-05 Fe-55 1.28E-05 6.80E-06 2.1OE-06 No Data No Data 3.OOE-05 7.75E-07 Fe-59 5.59E-06 9.04E-06 4.51 E-06 No Data No Data 3.43E-04 1.91 E-05 Co-58 No Data 4.79E-07 8.55E-07 No Data No Data 2.99E-04 9.29E-06 Co-60 No Data 3.55E-06 6.12E-06 No Data No Data 1.91E-03 2.60E-05 Ni-63 2.22E-04 1.25E-05 7.56E-06 No Data No Data 7.43E-05 1.71E-06 Ni-65 8.08E-10 7.99E-11 4.44E-11 No Data No Data 2.21 E-06 2.27E-05 Cu-64 No Data 5.39E-10 2.90E-10 No Data 1.63E-09 2.59E-06 9.92E-06 Zn-65 1.15E-05 3.06E-05 1.90E-05 No Data 1.93E-05 2.69E-04 4.41 E-06 Zn-69 1.81E-11 2.61E-11 2.41E-12 No Data 1.58E-11 3.84E-07 2.75E-06 Br-83 No Data No Data 1.28E-07 No Data No Data No Data No Data Br-84 No Data No Data 1.48E-07 No Data No Data No Data No Data Br-85 No Data No Data 6.84E-09 No Data No Data No Data No Data Rb-86 No Data 5.36E-05 3.09E-05 No Data No Data No Data 2.16E-06 Rb-88 No Data 1.52E-07 9.90E-08 No Data No Data No Data 4.66E-09 Rb-89 No Data 9.33E-08 7.83E-08 No Data No Data No Data 5.11 E-1 0 Sr-89 1.62E-04 No Data 4.66E-06 No Data No Data 5.83E-04 4.52E-05 Sr-90 2.73E-02 No Data 1.74E-03 No Data No Data 3.99E-03 9.28E-05 Sr-91 3.28E-08 No Data 1.24E-09 No Data No Data 1.44E-05 4.70E-05 All values are in (mrem/pCi inhaled). | |||
They are obtained from Reference 3 (Table E-9). Neither Reference 2 nor Reference 3 contains data for Rh-105, Sb-1 24, or Sb-1 25.9-21 VER 29 VEGP ODCM 9-22 VER 29 VEGP ODCM Table 9-8 (contd).Inhalation Dose Factors for the Child Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 3.54E-09 No Data 1.42E-10 No Data No Data 6.49E-06 6.55E-05 Y-90 1.11E-06 No Data 2.99E-08 No Data No Data 7.07E-05 7.24E-05 Y-91m 1.37E-10 No Data 4.98E-12 No Data No Data 7.60E-07 4.64E-07 Y-91 2.47E-04 No Data 6.59E-06 No Data No Data 7.1OE-04 4.97E-05 Y-92 5.50E-09 No Data 1.57E-10 No Data No Data 6.46E-06 6.46E-05 Y-93 5.04E-08 No Data 1.38E-09 No Data No Data 2.01 E-05 1.05E-04 Zr-95 5.13E-05 1.13E-05 1.OOE-05 No Data 1.61E-05 6.03E-04 1.65E-05 Zr-97 5.07E-08 7.34E-09 4.32E-09 No Data 1.05E-08 3.06E-05 9.49E-05 Nb-95 6.35E-06 2.48E-06 1.77E-06 No Data 2.33E-06 1.66E-04 11.00E-05 Mo-99 No Data 4.66E-08 1.15E-08 No Data 1.06E-07 3.66E-05 3.42E-05 Tc-99m 4.81E-13 9.41E-13 1.56E-11 No Data 1.37E-11 2.57E-07 1.30E-06 Tc-101 2.19E-14 2.30E-14 2.91E-13 No Data 3.92E-13 1.58E-07 4.41E-09 Ru-103 7.55E-07 No Data 2.90E-07 No Data 1.90E-06 1.79E-04 1.21E-05 Ru-105 4.13E-10 No Data 1.50E-10 No Data 3.63E-10 4.30E-06 2.69E-05 Ru-106 3.68E-05 No Data 4.57E-06 No Data 4.97E-05 3.87E-03 1.16E-04 Rh-105 No Data No Data No Data No Data No Data No Data No Data Ag-1 10m 4.56E-06 3.08E-06 2.47E-06 No Data 5.74E-06 1.48E-03 2.71 E-05 Sb-124 No Data No Data No Data No Data No Data No Data No Data Sb-125 No Data No Data No Data No Data No Data No Data No Data Te-125m 1.82E-06 6.29E-07 2.47E-07 5.20E-07 No Data 1.29E-04 9.13E-06 Te-127m 6.72E-06 2.31E-06 8.16E-07 1.64E-06 1.72E-05 4.OOE-04 1.93E-05 Te-127 7.49E-10 2.57E-10 1.65E-10 5.30E-10 1.91E-09 2.71E-06 1.52E-05 Te-129m 5.19E-06 1.85E-06 8.22E-07 1.71E-06 1.36E-05 4.76E-04 4.91E-05 Te-129 2.64E-11 9.45E-12 6.44E-12 1.93E-11 6.94E-11 7.93E-07 6.89E-06 Te-131m 3.63E-08 1.60E-08 1.37E-08 2.64E-08 1.08E-07 5.56E-05 8.32E-05 Te-131 5.87E-12 2.28E-12 1.78E-12 4.59E-12 1.59E-11 5.55E-07 3.60E-07 9-23 VER 29 VEGP ODCM Table 9-8 (contd). Inhalation Dose Factors for the Child Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 1.30E-07 7.36E-08 7.12E-08 8.58E-08 4.79E-07 1.02E-04 3.72E-05 1-130 2.21E-06 4.43E-06 2.28E-06 4.99E-04 6.61E-06 No Data 1.38E-06 1-131 1.30E-05 1.30E-05 7.37E-06 4.39E-03 2.13E-05 No Data 7.68E-07 1-132 5.72E-07 1.1OE-06 5.07E-07 5.23E-05 1.69E-06 No Data 8.65E-07 1-133 4.48E-06 5.49E-06 2.08E-06 1.04E-03 9.13E-06 No Data 1.48E-06 1-134 3.17E-07 5.84E-07 2.69E-07 1.37E-05 8.92E-07 No Data 2.58E-07 1-135 1.33E-06 2.36E-06 1.12E-06 2.14E-04 3.62E-06 No Data 1.20E-06 Cs-134 1.76E-04 2.74E-04 6.07E-05 No Data 8.93E-05 3.27E-05 1.04E-06 Cs-136 1.76E-05 4.62E-05 3.14E-05 No Data 2.58E-05 3.93E-06 1.13E-06 Cs-137 2.45E-04 2.23E-04 3.47E-05 No Data 7.63E-05 2.81E-05 9.78E-07 Cs-138 1.71E-07 2.27E-07 1.50E-07 No Data 1.68E-07 1.84E-08 7.29E-08 Ba-139 4.98E-10 2.66E-13 1.45E-11 No Data 2.33E-13 1.56E-06 1.56E-05 Ba-140 2.OOE-05 1.75E-08 1.17E-06 No Data 5.71E-09 4.71E-04 2.75E-05 Ba-141 5.29E-11 2.95E-14 1.72E-12 No Data 2.56E-14 7.89E-07 7.44E-08 Ba-142 1.35E-11 9.73E-15 7.54E-13 No Data 7.87E-15 4.44E-07 7.41 E-10 La-140 1.74E-07 6.08E-08 2.04E-08 No Data No Data 4.94E-05 6.1OE-05 La-142 3.50E-10 1.11E-10 3.49E-11 No Data No Data 2.35E-06 2.05E-05 Ce-141 1.06E-05 5.28E-06 7.83E-07 No Data 2.31E-06 1.47E-04 1.53E-05 Ce-143 9.89E-08 5.37E-08 7.77E-09 No Data 2.26E-08 3.12E-05 3.44E-05 Ce-144 1.83E-03 5.72E-04 9.77E-05 No Data 3.17E-04 3.23E-03 1.05E-04 Pr-143 4.99E-06 1.50E-06 2.47E-07 No Data 8.11E-07 1.17E-04 2.63E-05 Pr-144 1.61E-11 4.99E-12 8.10E-13 No Data 2.64E-12 4.23E-07 5.32E-08 Nd-147 2.92E-06 2.36E-06 1.84E-07 No Data 1.30E-06 8.87E-05 2.22E-05 W-187 4.41E-09 2.61E-09 1.17E-09 No Data No Data 1.11E-05 2.46E-05 Np-239 1.26E-07 9.04E-09 6.35E-09 No Data 2.63E-08 1.57E-05 1.73E-05 9-24 VER 29 VEGP ODCM Table 9-9. Inhalation Dose Factors for the Teenager Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI H-3 No Data 1.59E-07 1.59E-07 1.59E-07 1.59E-07 1.59E-07 1.59E-07 C-14 3.25E-06 6.09E-07 6.09E-07 6.09E-07 6.09E-07 6.09E-07 6.09E-07 Na-24 1.72E-06 1.72E-06 1.72E-06 1.72E-06 1.72E-06 1.72E-06 1.72E-06 P-32 2.36E-04 1.37E-08 8.95E-06 No Data No Data No Data 1.16E-05 Cr-51 No Data No Data 1.69E-08 9.37E-09 3.84E-09 2.62E-06 3.75E-07 Mn-54 No Data 6.39E-06 1.05E-06 No Data 1.59E-06 2.48E-04 8.35E-06 Mn-56 No Data 2.12E-10 3.15E-11 No Data 2.24E-10 1.90E-06 7.18E-06 Fe-55 4.18E-06 2.98E-06 6.93E-07 No Data No Data 1.55E-05 7.99E-07 Fe-59 1.99E-06 4.62E-06 1.79E-06 No Data No Data 1.91 E-04 2.23E-05 Co-58 No Data 2.59E-07 3.47E-07 No Data No Data 1.68E-04 1.1 9E-05 Co-60 No Data 1.89E-06 2.48E-06 No Data No Data 1.09E-03 3.24E-05 Ni-63 7.25E-05 5.43E-06 2.47E-06 No Data No Data 3.84E-05 1.77E-06 Ni-65 2.73E-10 3.66E-11 1.59E-11 No Data No Data 1.17E-06 4.59E-06 Cu-64 No Data 2.54E-10 1.06E-10 No Data 8.01E-10 1.39E-06 7.68E-06 Zn-65 4.82E-06 1.67E-05 7.80E-06 No Data 1.08E-05 1.55E-04 5.83E-06 Zn-69 6.04E-12 1.15E-11 8.07E-13 No Data 7.53E-12 1.98E-07 3.56E-08 Br-83 No Data No Data 4.30E-08 No Data No Data No Data No Data Br-84 No Data No Data 5.41 E-08 No Data No Data No Data No Data Br-85 No Data No Data 2.29E-09 No Data No Data No Data No Data Rb-86 No Data 2.38E-05 1.05E-05 No Data No Data No Data 2.21 E-06 Rb-88 No Data 6.82E-08 3.40E-08 No Data No Data No Data 3.65E-15 Rb-89 No Data 4.40E-08 2.91E-08 No Data No Data No Data 4.22E-17 Sr-89 5.43E-05 No Data 1.56E-06 No Data No Data 3.02E-04 4.64E-05 Sr-90 1.35E-02 No Data 8.35E-04 No Data No Data 2.06E-03 9.56E-05 Sr-91 1.1OE-08 No Data 4.39E-10 No Data No Data 7.59E-06 3.24E-05 All values are in (mrem/pCi inhaled). | |||
They are obtained from Reference 3 (Table E-8). Neither Reference 2 nor Reference 3 contains data for Rh-1 05, Sb-124, or Sb-125.9-25 VER 29 VEGP ODCM Table 9-9 (contd). Inhalation Dose Factors for the Teenager Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 1.19E-09 No Data 5.08E- 11 No Data No Data 3.43E-06 1.49E-05 Y-90 3.73E-07 No Data 1.OOE-08 No Data No Data 3.66E-05 6.99E-05 Y-91m 4.63E-11 No Data 1.77E-12 No Data No Data 4.OOE-07 3.77E-09 Y-91 8.26E-05 No Data 2.21E-06 No Data No Data 3.67E-04 5.11E-05 Y-92 1.84E-09 No Data 5.36E-1 1 No Data No Data 3.35E-06 2.06E-05 Y-93 1.69E-08 No Data 4.65E-10 No Data No Data 1.04E-05 7.24E-05 Zr-95 1.82E-05 5.73E-06 3.94E-06 No Data 8.42E-06 3.36E-04 1.86E-05 Zr-97 1.72E-08 3.40E-09 1.57E-09 No Data 5.15E-09 1.62E-05 7.88E-05 Nb-95 2.32E-06 1.29E-06 7.08E-07 No Data 1.25E-06 9.39E-05 1.21E-05 Mo-99 No Data 2.11E-08 4.03E-09 No Data 5.14E-08 1.92E-05 3.36E-05 Tc-99m 1.73E-13 4.83E-13 6.24E-12 No Data 7.20E-12 1.44E-07 7.66E-07 Tc-101 7.40E-15 1.05E-14 1.03E-13 No Data 1.90E-13 8.34E-08 1.09E-16 Ru-103 2.63E-07 No Data 1.12E-07 No Data 9.29E-07 9.79E-05 1.36E-05 Ru-105 1.40E-10 No Data 5.42E-11 No Data 1.76E-10 2.27E-06 1.13E-05 Ru-106 1.23E-05 No Data 1.55E-06 No Data 2.38E-05 2.01E-03 1.20E-04 Rh-105 No Data No Data No Data No Data No Data No Data No Data Ag-110m 1.73E-06 1.64E-06 9.99E-07 No Data 3.13E-06 8.44E-04 3.41E-05 Sb-124 No Data No Data No Data No Data No Data No Data No Data Sb-125 No Data No Data No Data No Data No Data No Data No Data Te-125m 6.1OE-07 2.80E-07 8.34E-08 1.75E-07 No Data 6.70E-05 9.38E-06 Te-127m 2.25E-06 1.02E-06 2.73E-07 5.48E-07 8.17E-06 2.07E-04 1.99E-05 Te-127 2.51E-10 1.14E-10 5.52E-11 1.77E-10 9.10E-10 1.40E-06 1.01E-05 Te-129m 1.74E-06 8.23E-07 2.81E-07 5.72E-07 6.49E-06 2.47E-04 5.06E-05 Te-129 8.87E-12 4.22E-12 2.20E-12 6.48E-12 3.32E-11 4.12E-07 2.02E-07 Te-131m 1.23E-08 7.51E-09 5.03E-09 9.06E-09 5.49E-08 2.97E-05 7.76E-05 Te-131 1.97E-12 1.04E-12 6.30E-13 1.55E-12 7.72E-12 2.92E-07 1.89E-09 9-26 VER 29 VEGP ODCM Table 9-9 (contd). Inhalation Dose Factors for the Teenager Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 4.50E-08 3.63E-08 2.74E-08 3.07E-08 2.44E-07 5.61E-05 5.79E-05 1-130 7.80E-07 2.24E-06 8.96E-07 1.86E-04 3.44E-06 No Data 1.14E-06 1-131 4.43E-06 6.14E-06 3.30E-06 1.83E-03 1.05E-05 No Data 8.11E-07 1-132 1.99E-07 5.47E-07 1.97E-07 1.89E-05 8.65E-07 No Data 1.59E-07 1-133 1.52E-06 2.56E-06 7.78E-07 3.65E-04 4.49E-06 No Data 1.29E-06 1-134 1.11E-07 2.90E-07 1.05E-07 4.94E-06 4.58E-07 No Data 2.55E-09 1-135 4.62E-07 1.18E-06 4.36E-07 7.76E-05 1.86E-06 No Data 8.69E-07 Cs-134 6.28E-05 1.41E-04 6.86E-05 No Data 4.69E-05 1.83E-05 1.22E-06 Cs-136 6.44E-06 2.42E-05 1.71E-05 No Data 1.38E-05 2.22E-06 1.36E-06 Cs-137 8.38E-05 1.06E-04 3.89E-05 No Data 3.80E-05 1.51E-05 1.06E-06 Cs-138 5.82E-08 1.07E-07 5.58E-08 No Data 8.28E-08 9.84E-09 3.38E-11 Ba-139 1.67E-10 1.18E-13 4.87E-12 No Data 1.11E-13 8.08E-07 8.06E-07 Ba-140 6.84E-06 8.38E-09 4.40E-07 No Data 2.85E-09 2.54E-04 2.86E-05 Ba-141 1.78E-11 1.32E-14 5.93E-13 No Data 1.23E-14 4.11E-07 9.33E-14 Ba-142 4.62E-12 4.63E-15 2.84E-13 No Data 3.92E-15 2.39E-07 5.99E-20 La-140 5.99E-08 2.95E-08 7.82E-09 No Data No Data 2.68E-05 6.09E-05 La-142 1.20E-10 5.31E-11 1.32E-11 No Data No Data 1.27E-06 1.50E-06 Ce-141 3.55E-06 2.37E-06 2.71E-07 No Data 1.11E-06 7.67E-05 1.58E-05 Ce-143 3.32E-08 2.42E-08 2.70E-09 No Data 1.08E-08 1.63E-05 3.19E-05 Ce-144 6.11E-04 2.53E-04 3.28E-05 No Data 1.51E-04 1.67E-03 1.08E-04 Pr-143 1.67E-06 6.64E-07 8.28E-08 No Data 3.86E-07 6.04E-05 2.67E-05 Pr-144 5.37E-12 2.20E-12 2.72E-13 No Data 1.26E-12 2.19E-07 2.94E-14 Nd-147 9.83E-07 1.07E-06 6.41E-08 No Data 6.28E-07 4.65E-05 2.28E-05 W-187 1.50E-09 1.22E-09 4.29E-10 No Data No Data 5.92E-06 2.21E-05 Np-239 4.23E-08 3.99E-09 2.21E-09 No Data 1.25E-08 8.11E-06 1.65E-05 9-27 VER 29 VEGP ODCM Table 9-10. Inhalation Dose Factors for the Adult Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 No Data 1.58E-07 1.58E-07 1.58E-07 1.58E-07 1.58E-07 1.58E-07 C-14 2.27E-06 4.26E-07 4.26E-07 4.26E-07 4.26E-07 4.26E-07 4.26E-07 Na-24 1.28E-06 1.28E-06 1.28E-06 1.28E-06 1.28E-06 1.28E-06 1.28E-06 P-32 1.65E-04 9.64E-06 6.26E-06 No Data No Data No Data 1.08E-05 Cr-51 No Data No Data 1.25E-08 7.44E-09 2.85E-09 1.80E-06 4.15E-07 Mn-54 No Data 4.95E-06 7.87E-07 No Data 1.23E-06 1.75E-04 9.67E-06 Mn-56 No Data 1.55E-10 2.29E-11 No Data 1.63E-10 1.18E-06 2.53E-06 Fe-55 3.07E-06 2.12E-06 4.93E-07 No Data No Data 9.01E-06 7.54E-07 Fe-59 1.47E-06 3.47E-06 1.32E-06 No Data No Data 1.27E-04 2.35E-05 Co-58 No Data 1.98E-07 2.59E-07 No Data No Data 1.16E-04 1.33E-05 Co-60 No Data 1.44E-06 1.85E-06 No Data No Data 7.46E-04 3.56E-05 Ni-63 5.40E-05 3.93E-06 1.81E-06 No Data No Data 2.23E-05 1.67E-06 Ni-65 1.92E-10 2.62E-11 1.14E-11 No Data No Data 7.OOE-07 1.54E-06 Cu-64 No Data 1.83E-10 7.69E-11 No Data 5.78E-10 8.48E-07 6.12E-06 Zn-65 4.05E-06 1.29E-05 5.82E-06 No Data 8.62E-06 1.08E-04 6.68E-06 Zn-69 4.23E-12 8.14E-12 5.65E-13 No Data 5.27E-12 1.15E-07 2.04E-09 Br-83 No Data No Data 3.01E-08 No Data No Data No Data 2.90E-08 Br-84 No Data No Data 3.91 E-08 No Data No Data No Data 2.05E-13 Br-85 No Data No Data 1.60E-09 No Data No Data No Data No Data Rb-86 No Data 1.69E-05 7.37E-06 No Data No Data No Data 2.08E-06 Rb-88 No Data 4.84E-08 2.41E-08 No Data No Data No Data 4.18E-19 Rb-89 No Data 3.20E-08 2.12E-08 No Data No Data No Data 1.16E-21 Sr-89 3.80E-05 No Data 1.09E-06 No Data No Data 1.75E-04 4.37E-05 Sr-90 1.24E-02 No Data 7.62E-04 No Data No Data 1.20E-03 9.02E-05 Sr-91 7.74E-09 No Data 3.13E-10 No Data No Data 4.56E-06 2.39E-05 All values are in (mrem/pCi inhaled). | |||
They are obtained from Reference 3 (Table E-7), except as follows: Reference 2 (Table C-1) for Rh-105, Sb-124, and Sb-125.9-28 VER 29 VEGP ODCM Table 9-10 (contd). Inhalation Dose Factors for the Adult Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 8.43E-1 0 No Data 3.64E-1 1 No Data No Data 2.06E-06 5.38E-06 Y-90 2.61E-07 No Data 7.01 E-09 No Data No Data 2.12E-05 6.32E-05 Y-91m 3.26E-11 No Data 1.27E-12 No Data No Data 2.40E-07 1.66E-10 Y-91 5.78E-05 No Data 1.55E-06 No Data No Data 2.13E-04 4.81 E-05 Y-92 1.29E-09 No Data 3.77E-11 No Data No Data 1.96E-06 9.19E-06 Y-93 1.18E-08 No Data 3.26E-10 No Data No Data 6.06E-06 5.27E-05 Zr-95 1.34E-05 4.30E-06 2.91E-06 No Data 6.77E-06 2.21E-04 1.88E-05 Zr-97 1.21E-08 2.45E-09 1.13E-09 No Data 3.71E-09 9.84E-06 6.54E-05 Nb-95 1.76E-06 9.77E-07 5.26E-07 No Data 9.67E-07 6.31E-05 1.30E-05 Mo-99 No Data 1.51E-08 2.87E-09 No Data 3.64E-08 1.14E-05 3.1OE-05 Tc-99m 1.29E-13 3.64E-13 4.63E-12 No Data 5.52E-12 9.55E-08 5.20E-07 Tc-101 5.22E-15 7.52E-15 7.38E-14 No Data 1.35E-13 4.99E-08 1.36E-21 Ru-103 1.91 E-07 No Data 8.23E-08 No Data 7.29E-07 6.31E-05 1.38E-05 Ru-105 9.88E-11 No Data 3.89E-11 No Data 1.27E-10 1.37E-06 6.02E-06 Ru-106 8.64E-06 No Data 1.09E-06 No Data 1.67E-05 1.17E-03 1.14E-04 Rh-105 9.24E-10 6.73E-10 4.43E-10 No Data 2.86E-09 2.41E-06 1.09E-05 Ag-110m 1.35E-06 1.25E-06 7.43E-07 No Data 2.46E-06 5.79E-04 3.78E-05 Sb-124 3.90E-06 7.36E-08 1.55E-06 9.44E-09 No Data 3.1OE-04 5.08E-05 Sb-125 8.26E-06 8.91E-08 1.66E-06 7.34E-09 No Data 2.75E-04 1.26E-05 Te-125m 4.27E-07 1.98E-07 5.84E-08 1.31E-07 1.55E-06 3.92E-05 8.83E-06 Te-127m 1.58E-06 7.21E-07 1.96E-07 4.11E-07 5.72E-06 1.20E-04 1.87E-05 Te-127 1.75E-10 8.03E-11 3.87E-11 1.32E-10 6.37E-10 8.14E-07 7.17E-06 Te-129m 1.22E-06 5.84E-07 1.98E-07 4.30E-07 4.57E-06 1.45E-04 4.79E-05 Te-129 6.22E-12 2.99E-12 1.55E-12 4.87E-12 2.34E-11 2.42E-07 1.96E-08 Te-131rm 8.74E-09 5.45E-09 3.63E-09 6.88E-09 3.86E-08 1.82E-05 6.95E-05 Te-131 1.39E-12 7.44E-13 4.49E-13 1.17E-12 5.46E-12 1.74E-07 2.30E-09 9-29 VER 29 VEGP ODCM Table 9-10 (contd). Inhalation Dose Factors for the Adult Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 3.25E-08 2.69E-08 2.02E-08 2.37E-08 1.82E-07 3.60E-05 6.37E-05 1-130 5.72E-07 1.68E-06 6.60E-07 1.42E-04 2.61E-06 No Data 9.61 E-07 1-131 3.15E-06 4.47E-06 2.56E-06 1.49E-03 7.66E-06 No Data 7.85E-07 1-132 1.45E-07 4.07E-07 1.45E-07 1.43E-05 6.48E-07 No Data 5.08E-08 1-133 1.08E-06 1.85E-06 5.65E-07 2.69E-04 3.23E-06 No Data 1.11E-06 1-134 8.05E-08 2.16E-07 7.69E-08 3.73E-06 3.44E-07 No Data 1.26E-10 1-135 3.35E-07 8.73E-07 3.21E-07 5.60E-05 1.39E-06 No Data 6.56E-07 Cs-134 4.66E-05 1.06E-04 9.1OE-05 No Data 3.59E-05 1.22E-05 1.30E-06 Cs-136 4.88E-06 1.83E-05 1.38E-05 No Data 1.07E-05 1.50E-06 1.46E-06 Cs-137 5.98E-05 7.76E-05 5.35E-05 No Data 2.78E-05 9.40E-06 1.05E-06 Cs-138 4.14E-08 7.76E-08 4.05E-08 No Data 6.OOE-08 6.07E-09 2.33E-13 Ba-139 1.17E-10 8.32E-14 3.42E-12 No Data 7.78E-14 4.70E-07 1.12E-07 Ba-140 4.88E-06 6.13E-09 3.21E-07 No Data 2.09E-09 1.59E-04 2.73E-05 Ba-141 1.25E-11 9.41E-15 4.20E-13 No Data 8.75E-15 2.42E-07 1.45E-17 Ba-142 3.29E-12 3.38E-15 2.07E-13 No Data 2.86E-15 1.49E-07 1.96E-26 La-140 4.30E-08 2.17E-08 5.73E-09 No Data No Data 1.70E-05 5.73E-05 La-142 8.54E-11 3.88E-11 9.65E-12 No Data No Data 7.91E-07 2.64E-07 Ce-141 2.49E-06 1.69E-06 1.91E-07 No Data 7.83E-07 4.52E-05 1.50E-05 Ce-143 2.33E-08 1.72E-08 1.91E-09 No Data 7.60E-09 9.97E-06 2.83E-05 Ce-144 4.29E-04 1.79E-04 2.30E-05 No Data 1.06E-04 9.72E-04 1.02E-04 Pr-143 1.17E-06 4.69E-07 5.80E-08 No Data 2.70E-07 3.51E-05 2.50E-05 Pr-144 3.76E-12 1.56E-12 1.91E-13 No Data 8.81E-13 1.27E-07 2.69E-18 Nd-147 6.59E-07 7.62E-07 4.56E-08 No Data 4.45E-07 2.76E-05 2.16E-05 W-187 1.06E-09 8.85E-10 3.10E-10 No Data No Data 3.63E-06 1.94E-05 Np-239 2.87E-08 2.82E-09 1.55E-09 No Data 8.75E-09 4.70E-06 1.49E-05 9-30 VER 29 VEGP ODCM Table 9-11. Ingestion Dose Factors for the Infant Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI H-3 No Data 3.08E-07 3.08E-07 3.08E-07 3.08E-07 3.08E-07 3.08E-07 C-14 2.37E-05 5.06E-06 5.06E-06 5.06E-06 5.06E-06 5.06E-06 5.06E-06 Na-24 1.01E-05 1.01E-05 1.01E-05 1.01E-05 1.01E-05 1.01E-05 1.01E-05 P-32 1.70E-03 1.OOE-04 6.59E-05 No Data No Data No Data 2.30E-05 Cr-51 No Data No Data 1.41E-08 9.20E-09 2.01E-09 1.79E-08 4.11E-07 Mn-54 No Data 1.99E-05 4.51E-06 No Data 4.41 E-06 No Data 7.31E-06 Mn-56 No Data 8.18E-07 1.41 E-07 No Data 7.03E-07 No Data 7.43E-05 Fe-55 1.39E-05 8.98E-06 2.40E-06 No Data No Data 4.39E-06 1.14E-06 Fe-59 3.08E-05 5.38E-05 2.12E-05 No Data No Data 1.59E-05 2.57E-05 Co-58 No Data 3.60E-06 8.98E-06 No Data No Data No Data 8.97E-06 Co-60 No Data 1.08E-05 2.55E-05 No Data No Data No Data 2.57E-05 Ni-63 6.34E-04 3.92E-05 2.20E-05 No Data No Data No Data 1.95E-06 Ni-65 4.70E-06 5.32E-07 2.42E-07 No Data No Data No Data 4.05E-05 Cu-64 No Data 6.09E-07 2.82E-07 No Data 1.03E-06 No Data 1.25E-05 Zn-65 1.84E-05 6.31E-05 2.91E-05 No Data 3.06E-05 No Data 5.33E-05 Zn-69 9.33E-08 1.68E-07 1.25E-08 No Data 6.98E-08 No Data 1.37E-05 Br-83 No Data No Data 3.63E-07 No Data No Data No Data No Data Br-84 No Data No Data 3.82E-07 No Data No Data No Data No Data Br-85 No Data No Data 1.94E-08 No Data No Data No Data No Data Rb-86 No Data 1.70E-04 8.40E-05 No Data No Data No Data 4.35E-06 Rb-88 No Data 4.98E-07 2.73E-07 No Data No Data No Data 4.85E-07 Rb-89 No Data 2.86E-07 1.97E-07 No Data No Data No Data 9.74E-08 Sr-89 2.51E-03 No Data 7.20E-05 No Data No Data No Data 5.16E-05 Sr-90 1.85E-02 No Data 4.71 E-03 No Data No Data No Data 2.31E-04 Sr-91 5.OOE-05 No Data 1.81 E-06 No Data No Data No Data 5.92E-05 All values are in (mrem/pCi ingested). | |||
They are obtained from Reference 3 (Table E-14). Neither Reference 2 nor Reference 3 contains data for Rh-105, Sb-124, or Sb-125.9-31 VER 29 VEGP ODCM Table 9-11 (contd). Ingestion Dose Factors for the Infant Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 1.92E-05 No Data 7.13E-07 No Data No Data No Data 2.07E-04 Y-90 8.69E-08 No Data 2.33E-09 No Data No Data No Data 1.20E-04 Y-91m 8.10E-10 No Data 2.76E-11 No Data No Data No Data 2.70E-06 Y-91 1.13E-06 No Data 3.01E-08 No Data No Data No Data 8.1OE-05 Y-92 7.65E-09 No Data 2.15E-10 No Data No Data No Data 1.46E-04 Y-93 2.43E-08 No Data 6.62E-10 No Data No Data No Data 1.92E-04 Zr-95 2.06E-07 5.02E-08 3.56E-08 No Data 5.41 E-08 No Data 2.50E-05 Zr-97 1.48E-08 2.54E-09 1.16E-09 No Data 2.56E-09 No Data 1.62E-04 Nb-95 4.20E-08 1.73E-08 1.OOE-08 No Data 1.24E-08 No Data 1.46E-05 Mo-99 No Data 3.40E-05 6.63E-06 No Data 5.08E-05 No Data 1.12E-05 Tc-99m 1.92E-09 3.96E-09 5.1OE-08 No Data 4.26E-08 2.07E-09 1.15E-06 Tc-101 2.27E-09 2.86E-09 2.83E-08 No Data 3.40E-08 1.56E-09 4.86E-07 Ru-103 1.48E-06 No Data 4.95E-07 No Data 3.08E-06 No Data 1.80E-05 Ru-105 1.36E-07 No Data 4.58E-08 No Data 1.OOE-06 No Data 5.41 E-05 Ru-106 2.41 E-05 No Data 3.01E-06 No Data 2.85E-05 No Data 1.83E-04 Rh-105 No Data No Data No Data No Data No Data No Data No Data Ag-110m 9.96E-07 7.27E-07 4.81E-07 No Data 1.04E-06 No Data 3.77E-05 Sb-124 No Data No Data No Data No Data No Data No Data No Data Sb-125 No Data No Data No Data No Data No Data No Data No Data Te-125m 2.33E-05 7.79E-06 3.15E-06 7.84E-06 No Data No Data 1.11E-05 Te-127m 5.85E-05 1.94E-05 7.08E-06 1.69E-05 1.44E-04 No Data 2.36E-05 Te-127 1.OOE-06 3.35E-07 2.15E-07 8.14E-07 2.44E-06 No Data 2.1OE-05 Te-129m 1.OOE-04 3.43E-05 1.54E-05 3.84E-05 2.50E-04 No Data 5.97E-05 Te-129 2.84E-07 9.79E-08 6.63E-08 2.38E-07 7.07E-07 No Data 2.27E-05 Te-131m 1.52E-05 6.12E-06 5.05E-06 1.24E-05 4.21E-05 No Data 1.03E-04 Te-131 1.76E-07 6.50E-08 4.94E-08 1.57E-07 4.50E-07 No Data 7.11E-06 9-32 VER 29 VEGP ODCM Table 9-11 (contd). Ingestion Dose Factors for the Infant Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 2.08E-05 1.03E-05 9.61E-06 1.52E-05 6.44E-05 No Data 3.81 E-05 1-130 6.OOE-06 1.32E-05 5.30E-06 1.48E-03 1.45E-05 No Data 2.83E-06 1-131 3.59E-05 4.23E-05 1.86E-05 1.39E-02 4.94E-05 No Data 1.51E-06 1-132 1.66E-06 3.37E-06 1.20E-06 1.58E-04 3.76E-06 No Data 2.73E-06 1-133 1.25E-05 1.82E-05 5.33E-06 3.31E-03 2.14E-05 No Data 3.08E-06 1-134 8.69E-07 1.78E-06 6.33E-07 4.15E-05 1.99E-06 No Data 1.84E-06 1-135 3.64E-06 7.24E-06 2.64E-06 6.49E-04 8.07E-06 No Data 2.62E-06 Cs-134 3.77E-04 7.03E-04 7.1OE-05 No Data 1.81E-04 7.42E-05 1.91 E-06 Cs-136 4.59E-05 1.35E-04 5.04E-05 No Data 5.38E-05 1.1OE-05 2.05E-06 Cs-137 5.22E-04 6.11E-04 4.33E-05 No Data 1.64E-04 6.64E-05 1.91E-06 Cs-138 4.81E-07 7.82E-07 3.79E-07 No Data 3.90E-07 6.09E-08 1.25E-06 Ba-139 8.81E-07 5.84E-10 2.55E-08 No Data 3.51E-10 3.54E-10 5.58E-05 Ba-140 1.71E-04 1.71E-07 8.81E-06 No Data 4.06E-08 1.05E-07 4.20E-05 Ba-141 4.25E-07 2.91E-10 1.34E-08 No Data 1.75E-10 1.77E-10 5.19E-06 Ba-142 1.84E-07 1.53E-10 9.06E-09 No Data 8.81E-11 9.26E-11 7.59E-07 La-140 2.11E-08 8.32E-09 2.14E-09 No Data No Data No Data 9.77E-05 La-142 1.1OE-09 4.04E-10 9.67E-11 No Data No Data No Data 6.86E-05 Ce-141 7.87E-08 4.80E-08 5.65E-09 No Data 1.48E-08 No Data 2.48E-05 Ce-143 1.48E-08 9.82E-06 1.12E-09 No Data 2.86E-09 No Data 5.73E-05 Ce-144 2.98E-06 1.22E-06 1.67E-07 No Data 4.93E-07 No Data 1.71E-04 Pr-143 8.13E-08 3.04E-08 4.03E-09 No Data 1.13E-08 No Data 4.29E-05 Pr-144 2.74E-10 1.06E-10 1.38E-11 No Data 3.84E-11 No Data 4.93E-06 Nd-147 5.53E-08 5.68E-08 3.48E-09 No Data 2.19E-08 No Data 3.60E-05 W-187 9.03E-07 6.28E-07 2.17E-07 No Data No Data No Data 3.69E-05 Np-239 1.11E-08 9.93E-10 5.61E-10 No Data 1.98E-09 No Data 2.87E-05 9-33 VER 29 VEGP ODCM Table 9-12. Ingestion Dose Factors for the Child Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 No Data 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 C-14 1.21E-05 2.42E-06 2.42E-06 2.42E-06 2.42E-06 2.42E-06 2.42E-06 Na-24 5.80E-06 5.80E-06 5.80E-06 5.80E-06 5.80E-06 5.80E-06 5.80E-06 P-32 8.25E-04 3.86E-05 3.18E-05 No Data No Data No Data 2.28E-05 Cr-51 No Data No Data 8.90E-09 4.94E-09 1.35E-09 9.02E-09 4.72E-07 Mn-54 No Data 1.07E-05 2.85E-06 No Data 3.OOE-06 No Data 8.98E-06 Mn-56 No Data 3.34E-07 7.54E-08 No Data 4.04E-07 No Data 4.84E-05 Fe-55 1.15E-05 6.1OE-06 1.89E-06 No Data No Data 3.45E-06 1.13E-06 Fe-59 1.65E-05 2.67E-05 1.33E-05 No Data No Data 7.74E-06 2.78E-05 Co-58 No Data 1.80E-06 5.51 E-06 No Data No Data No Data 1.05E-05 Co-60 No Data 5.29E-06 1.56E-05 No Data No Data No Data 2.93E-05 Ni-63 5.38E-04 2.88E-05 1.83E-05 No Data No Data No Data 1.94E-06 Ni-65 2.22E-06 2.09E-07 1.22E-07 No Data No Data No Data 2.56E-05 Cu-64 No Data 2.45E-07 1.48E-07 No Data 5.92E-07 No Data 1.15E-05 Zn-65 1.37E-05 3.65E-05 2.27E-05 No Data 2.30E-05 No Data 6.41 E-06 Zn-69 4.38E-08 6.33E-08 5.85E-09 No Data 3.84E-08 No Data 3.99E-06 Br-83 No Data No Data 1.71 E-07 No Data No Data No Data No Data Br-84 No Data No Data 1.98E-07 No Data No Data No Data No Data Br-85 No Data No Data 9.12E-09 No Data No Data No Data No Data Rb-86 No Data 6.70E-05 4.12E-05 No Data No Data No Data 4.31 E-06 Rb-88 No Data 1.90E-07 1.32E-07 No Data No Data No Data 9.32E-09 Rb-89 No Data 1.1 7E-07 1.04E-07 No Data No Data No Data 1.02E-09 Sr-89 1.32E-03 No Data 3.77E-05 No Data No Data No Data 5.11 E-05 Sr-90 1.70E-02 No Data 4.31 E-03 No Data No Data No Data 2.29E-04 Sr-91 2.40E-05 No Data 9.06E-07 No Data No Data No Data 5.30E-05 All values are in (mrem/pCi ingested). | |||
They are obtained from Reference 3 (Table E-13). Neither Reference 2 nor Reference 3 contains data for Rh-105, Sb-124, or Sb-125.9-34 VER 29 VEGP ODCM Table 9-12 (contd). Ingestion Dose Factors for the Child Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 9.03E-06 No Data 3.62E-07 No Data No Data No Data 1.71 E-04 Y-90 4.11E-08 No Data 1.10E-09 No Data No Data No Data 1.17E-04 Y-91m 3.82E-10 No Data 1.39E-11 No Data No Data No Data 7.48E-07 Y-91 6.02E-07 No Data 1.61 E-08 No Data No Data No Data 8.02E-05 Y-92 3.60E-09 No Data 1.03E-10 No Data No Data No Data 1.04E-04 Y-93 1.14E-08 No Data 3.13E-10 No Data No Data No Data 1.70E-04 Zr-95 1.16E-07 2.55E-08 2.27E-08 No Data 3.65E-08 No Data 2.66E-05 Zr-97 6.99E-09 1.01E-09 5.96E-10 No Data 1.45E-09 No Data 1.53E-04 Nb-95 2.25E-08 8.76E-09 6.26E-09 No Data 8.23E-09 No Data 1.62E-05 Mo-99 No Data 1.33E-05 3.29E-06 No Data 2.84E-05 No Data 1.1 OE-05 Tc-99m 9.23E-10 1.81E-09 3.OOE-08 No Data 2.63E-08 9.19E-10 1.03E-06 Tc-101 1.07E-09 1.12E-09 1.42E-08 No Data 1.91E-08 5.92E-10 3.56E-09 Ru-103 7.31 E-07 No Data 2.81E-07 No Data 1.84E-06 No Data 1.89E-05 Ru-105 6.45E-08 No Data 2.34E-08 No Data 5.67E-07 No Data 4.21E-05 Ru-106 1.17E-05 No Data 1.46E-06 No Data 1.58E-05 No Data 1.82E-04 Rh-105 No Data No Data No Data No Data No Data No Data No Data Ag-110m 5.39E-07 3.64E-07 2.91E-07 No Data 6.78E-07 No Data 4.33E-05 Sb-124 No Data No Data No Data No Data No Data No Data No Data Sb-125 No Data No Data No Data No Data No Data No Data No Data Te-125m 1.14E-05 3.09E-06 1.52E-06 3.20E-06 No Data No Data 1.10E-05 Te-127m 2.89E-05 7.78E-06 3.43E-06 6.91E-06 8.24E-05 No Data 2.34E-05 Te-127 4.71 E-07 1.27E-07 1.01E-07 3.26E-07 1.34E-06 No Data 1.84E-05 Te-129m 4.87E-05 1.36E-05 7.56E-06 1.57E-05 1.43E-04 No Data 5.94E-05 Te-129 1.34E-07 3.74E-08 3.18E-08 9.56E-08 3.92E-07 No Data 8.34E-06 Te-131m 7.20E-06 2.49E-06 2.65E-06 5.12E-06 2.41E-05 No Data 1.01E-04 Te-131 8.30E-08 2.53E-08 2.47E-08 6.35E-08 2.51E-07 No Data 4.36E-07 9-35 VER 29 VEGP ODCM Table 9-12 (contd). Ingestion Dose Factors for the Child Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 1.01E-05 4.47E-06 5.40E-06 6.51E-06 4.15E-05 No Data 4.50E-05 1-130 2.92E-06 5.90E-06 3.04E-06 6.50E-04 8.82E-06 No Data 2.76E-06 1-131 1.72E-05 1.73E-05 9.83E-06 5.72E-03 2.84E-05 No Data 1.54E-06 1-132 8.OOE-07 1.47E-06 6.76E-07 6.82E-05 2.25E-06 No Data 1.73E-06 1-133 5.92E-06 7.32E-06 2.77E-06 1.36E-03 1.22E-05 No Data 2.95E-06 1-134 4.19E-07 7.78E-07 3.58E-07 1.79E-05 1.19E-06 No Data 5.16E-07 1-135 1.75E-06 3.15E-06 1.49E-06 2.79E-04 4.83E-06 No Data 2.40E-06 Cs-134 2.34E-04 3.84E-04 8.1OE-05 No Data 1.19E-04 4.27E-05 2.07E-06 Cs-136 2.35E-05 6.46E-05 4.18E-05 No Data 3.44E-05 5.13E-06 2.27E-06 Cs-137 3.27E-04 3.13E-04 4.62E-05 No Data 1.02E-04 3.67E-05 1.96E-06 Cs-138 2.28E-07 3.17E-07 2.01E-07 No Data 2.23E-07 2.40E-08 1.46E-07 Ba-139 4.14E-07 2.21E-10 1.20E-08 No Data 1.93E-10 1.30E-10 2.39E-05 Ba-140 8.31E-05 7.28E-08 4.85E-06 No Data 2.37E-08 4.34E-08 4.21E-05 Ba-141 2.OOE-07 1.12E-10 6.51E-09 No Data 9.69E-11 6.58E-10 1.14E-07 Ba-142 8.74E-08 6.29E-11 4.88E-09 No Data 5.09E-11 3.70E-11 1.14E-09 La-140 1.01E-08 3.53E-09 1.19E-09 No Data No Data No Data 9.84E-05 La-142 5.24E-10 1.67E-10 5.23E-11 No Data No Data No Data 3.31E-05 Ce-141 3.97E-08 1.98E-08 2.94E-09 No Data 8.68E-09 No Data 2.47E-05 Ce-143 6.99E-09 3.79E-06 5.49E-10 No Data 1.59E-09 No Data 5.55E-05 Ce-144 2.08E-06 6.52E-07 1.11E-07 No Data 3.61E-07 No Data 1.70E-04 Pr-143 3.93E-08 1.18E-08 1.95E-09 No Data 6.39E-09 No Data 4.24E-05 Pr-144 1.29E-10 3.99E-11 6.49E-12 No Data 2.11E-11 No Data 8.59E-08 Nd-147 2.79E-08 2.26E-08 1.75E-09 No Data 1.24E-08 No Data 3.58E-05 W-187 4.29E-07 2.54E-07 1.14E-07 No Data No Data No Data 3.57E-05 Np-239 5.25E-09 3.77E-10 2.65E-10 No Data 1.09E-09 No Data 2.79E-05 9-36 VER 29 VEGP ODCM Table 9-13. Ingestion Dose Factors for the Teenager Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 No Data 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 C-14 4.06E-06 8.12E-07 8.12E-07 8.12E-07 8.12E-07 8.12E-07 8.12E-07 Na-24 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 P-32 2.76E-04 1.71 E-05 1.07E-05 No Data No Data No Data 2.32E-05 Cr-51 No Data No Data 3.60E-09 2.OOE-09 7.89E-10 5.14E-09 6.05E-07 Mn-54 No Data 5.90E-06 1.17E-06 No Data 1.76E-06 No Data 1.21E-05 Mn-56 No Data 1.58E-07 2.81E-08 No Data 2.OOE-07 No Data 1.04E-05 Fe-55 3.78E-06 2.68E-06 6.25E-07 No Data No Data 1.70E-06 1.16E-06 Fe-59 5.87E-06 1.37E-05 5.29E-06 No Data No Data 4.32E-06 3.24E-05 Co-58 No Data 9.72E-07 2.24E-06 No Data No Data No Data 1.34E-05 Co-60 No Data 2.81E-06 6.33E-06 No Data No Data No Data 3.66E-05 Ni-63 1.77E-04 1.25E-05 6.OOE-06 No Data No Data No Data 1.99E-06 Ni-65 7.49E-07 9.57E-08 4.36E-08 No Data No Data No Data 5.19E-06 Cu-64 No Data 1.15E-07 5.41E-08 No Data 2.91 E-07 No Data 8.92E-06 Zn-65 5.76E-06 2.OOE-05 9.33E-06 No Data 1.28E-05 No Data 8.47E-06 Zn-69 1.47E-08 2.80E-08 1.96E-09 No Data 1.83E-08 No Data 5.16E-08 Br-83 No Data No Data 5.74E-08 No Data No Data No Data No Data Br-84 No Data No Data 7.22E-08 No Data No Data No Data No Data Br-85 No Data No Data 3.05E-09 No Data No Data No Data No Data Rb-86 No Data 2.98E-05 1.40E-05 No Data No Data No Data 4.41 E-06 Rb-88 No Data 8.52E-08 4.54E-08 No Data No Data No Data 7.30E-15 Rb-89 No Data 5.50E-08 3.89E-08 No Data No Data No Data 8.43E-17 Sr-89 4.40E-04 No Data 1.26E-05 No Data No Data No Data 5.24E-05 Sr-90 8.30E-03 No Data 2.05E-03 No Data No Data No Data 2.33E-04 Sr-91 8.07E-06 No Data 3.21 E-07 No Data No Data No Data 3.66E-05 All values are in (mrem/pCi ingested). | |||
They are obtained from Reference 3 (Table E-12). Neither Reference 2 nor Reference 3 contains data for Rh-1 05, Sb-1 24, or Sb-1 25.9-37 VER 29 VEGP ODCM Table 9-13 (contd). Ingestion Dose Factors for the Teenager Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 3.05E-06 No Data 1.30E-07 No Data No Data No Data 7.77E-05 Y-90 1.37E-08 No Data 3.69E-10 No Data No Data No Data 1.13E-04 Y-91m 1.29E-10 No Data 4.93E-12 No Data No Data No Data 6.09E-09 Y-91 2.01E-07 No Data 5.39E-09 No Data No Data No Data 8.24E-05 Y-92 1.21E-09 No Data 3.50E-11 No Data No Data No Data 3.32E-05 Y-93 3.83E-09 No Data 1.05E-10 No Data No Data No Data 1.17E-04 Zr-95 4.12E-08 1.30E-08 8.94E-09 No Data 1.91 E-08 No Data 3.OOE-05 Zr-97 2.37E-09 4.69E-10 2.16E-10 No Data 7.11E-10 No Data 1.27E-04 Nb-95 8.22E-09 4.56E-09 2.51E-09 No Data 4.42E-09 No Data 1.95E-05 Mo-99 No Data 6.03E-06 1.15E-06 No Data 1.38E-05 No Data 1.08E-05 Tc-99m 3.32E-10 9.26E-10 1.20E-08 No Data 1.38E-08 5.14E-10 6.08E-07 Tc-101 3.60E-10 5.12E-10 5.03E-09 No Data 9.26E-09 3.12E-10 8.75E-17 Ru-103 2.55E-07 No Data 1.09E-07 No Data 8.99E-07 No Data 2.13E-05 Ru-105 2.18E-08 No Data 8.46E-09 No Data 2.75E-07 No Data 1.76E-05 Ru-106 3.92E-06 No Data 4.94E-07 No Data 7.56E-06 No Data 1.88E-04 Rh-1 05 No Data No Data No Data No Data No Data No Data No Data Ag-110m 2.05E-07 1.94E-07 1.18E-07 No Data 3.70E-07 No Data 5.45E-05 Sb-124 No Data No Data No Data No Data No Data No Data No Data Sb-1 25 No Data No Data No Data No Data No Data No Data No Data Te-125m 3.83E-06 1.38E-06 5.12E-07 1.07E-06 No Data No Data 1.13E-05 Te-127m 9.67E-06 3.43E-06 1.15E-06 2.30E-06 3.92E-05 No Data 2.41E-05 Te-127 1.58E-07 5.60E-08 3.40E-08 1.09E-07 6.40E-07 No Data 1.22E-05 Te-129m 1.63E-05 6.05E-06 2.58E-06 5.26E-06 6.82E-05 No Data 6.12E-05 Te-129 4.48E-08 1.67E-08 1.09E-08 3.20E-08 1.88E-07 No Data 2.45E-07 Te-131m 2.44E-06 1.17E-06 9.76E-07 1.76E-06 1.22E-05 No Data 9.39E-05 Te-131 2.79E-08 1.15E-08 8.72E-09 2.15E-08 1.22E-07 No Data 2.29E-09 9-38 VER 29 VEGP ODCM Table 9-13 (contd). Ingestion Dose Factors for the Teenager Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 3.49E-06 2.21E-06 2.08E-06 2.33E-06 2.12E-05 No Data 7.OOE-05 1-130 1.03E-06 2.98E-06 1.19E-06 2.43E-04 4.59E-06 No Data 2.29E-06 1-131 5.85E-06 8.19E-06 4.40E-06 2.39E-03 1.41E-05 No Data 1.62E-06 1-132 2.79E-07 7.30E-07 2.62E-07 2.46E-05 1.15E-06 No Data 3.18E-07 1-133 2.01E-06 3.41E-06 1.04E-06 4.76E-04 5.98E-06 No Data 2.58E-06 1-134 1.46E-07 3.87E-07 1.39E-07 6.45E-06 6.1OE-07 No Data 5.1OE-09 1-135 6.1OE-07 1.57E-06 5.82E-07 1.01E-04 2.48E-06 No Data 1.74E-06 Cs-134 8.37E-05 1.97E-04 9.14E-05 No Data 6.26E-05 2.39E-05 2.45E-06 Cs-136 8.59E-06 3.38E-05 2.27E-05 No Data 1.84E-05 2.90E-06 2.72E-06 Cs-137 1.12E-04 1.49E-04 5.19E-05 No Data 5.07E-05 1.97E-05 2.12E-06 Cs-138 7.76E-08 1.49E-07 7.45E-08 No Data 1.1OE-07 1.28E-08 6.76E-11 Ba-139 1.39E-07 9.78E-11 4.05E-09 No Data 9.22E-11 6.74E-11 1.24E-06 Ba-140 2.84E-05 3.48E-08 1.83E-06 No Data 1.18E-08 2.34E-08 4.38E-05 Ba-141 6.71E-08 5.01E-11 2.24E-09 No Data 4.65E-11 3.43E-11 1.43E-13 Ba-142 2.99E-08 2.99E-11 1.84E-09 No Data 2.53E-11 1.99E-11 9.18E-20 La-140 3.48E-09 1.71E-09 4.55E-10 No Data No Data No Data 9.82E-05 La-142 1.79E-10 7.95E-11 1.98E-11 No Data No Data No Data 2.42E-06 Ce-141 1.33E-08 8.88E-09 1.02E-09 No Data 4.18E-09 No Data 2.54E-05 Ce-143 2.35E-09 1.71E-06 1.91E-10 No Data 7.67E-10 No Data 5.14E-05 Ce-144 6.96E-07 2.88E-07 3.74E-08 No Data 1.72E-07 No Data 1.75E-04 Pr-143 1.31E-08 5.23E-09 6.52E-10 No Data 3.04E-09 No Data 4.31E-05 Pr-144 4.30E-11 1.76E-11 2.18E-12 No Data 1.01 E-11 No Data 4.74E-14 Nd-147 9.38E-09 1.02E-08 6.11E-10 No Data 5.99E-09 No Data 3.68E-05 W-187 1.46E-07 1.19E-07 4.17E-08 No Data No Data No Data 3.22E-05 Np-239 1.76E-09 1.66E-10 9.22E-11 No Data 5.21E-10 No Data 2.67E-05 9-39 VER 29 VEGP ODCM Table 9-14. Ingestion Dose Factors for the Adult Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 No Data 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 C-14 2.84E-06 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 Na-24 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 P-32 1.93E-04 1.20E-05 7.46E-06 No Data No Data No Data 2.17E-05 Cr-51 No Data No Data 2.66E-09 1.59E-09 5.86E-10 3.53E-09 6.69E-07 Mn-54 No Data 4.57E-06 8.72E-07 No Data 1.36E-06 No Data 1.40E-05 Mn-56 No Data 1.15E-07 2.04E-08 No Data 1.46E-07 No Data 3.67E-06 Fe-55 2.75E-06 1.90E-06 4.43E-07 No Data No Data 1.06E-06 1.09E-06 Fe-59 4.34E-06 1.02E-05 3.91 E-06 No Data No Data 2.85E-06 3.40E-05 Co-58 No Data 7.45E-07 1.67E-06 No Data No Data No Data 1.51 E-05 Co-60 No Data 2.14E-06 4.72E-06 No Data No Data No Data 4.02E-05 Ni-63 1.30E-04 9.01E-06 4.36E-06 No Data No Data No Data 1.88E-06 Ni-65 5.28E-07 6.86E-08 3.13E-08 No Data No Data No Data 1.74E-06 Cu-64 No Data 8.33E-08 3.91E-08 No Data 2.1OE-07 No Data 7.1OE-06 Zn-65 4.84E-06 1.54E-05 6.96E-06 No Data 1.03E-05 No Data 9.70E-06 Zn-69 1.03E-08 1.97E-08 1.37E-09 No Data 1.28E-08 No Data 2.96E-09 Br-83 No Data No Data 4.02E-08 No Data No Data No Data 5.79E-08 Br-84 No Data No Data 5.21E-08 No Data No Data No Data 4.09E-13 Br-85 No Data No Data 2.14E-09 No Data No Data No Data No Data Rb-86 No Data 2.11 E-05 9.83E-06 No Data No Data No Data 4.16E-06 Rb-88 No Data 6.05E-08 3.21E-08 No Data No Data No Data 8.36E-19 Rb-89 No Data 4.01E-08 2.82E-08 No Data No Data No Data 2.33E-21 Sr-89 3.08E-04 No Data 8.84E-06 No Data No Data No Data 4.94E-05 Sr-90 7.58E-03 No Data 1.86E-03 No Data No Data No Data 2.19E-04 Sr-91 5.67E-06 No Data 2.29E-07 No Data No Data No Data 2.70E-05 All values are in (mrem/pCi ingested). | |||
They are obtained from Reference 3 (Table E-1 1), except as follows: Reference 2 (Table A-3) for Rh-1 05, Sb-1 24, and Sb-125.9-40 VER 29 VEGP ODCM Table 9-14 (contd). Ingestion Dose Factors for the Adult Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 2.15E-06 No Data 9.30E-08 No Data No Data No Data 4.26E-05 Y-90 9.62E-09 No Data 2.58E-10 No Data No Data No Data 1.02E-04 Y-91m 9.09E-11 No Data 3.52E-12 No Data No Data No Data 2.67E-10 Y-91 1.41E-07 No Data 3.77E-09 No Data No Data No Data 7.76E-05 Y-92 8.45E-10 No Data 2.47E-11 No Data No Data No Data 1.48E-05 Y-93 2.68E-09 No Data 7.40E-11 No Data No Data No Data 8.50E-05 Zr-95 3.04E-08 9.75E-09 6.60E-09 No Data 1.53E-08 No Data 3.09E-05 Zr-97 1.68E-09 3.39E-10 1.55E-10 No Data 5.12E-10 No Data 1.05E-04 Nb-95 6.22E-09 3.46E-09 1.86E-09 No Data 3.42E-09 No Data 2.1OE-05 Mo-99 No Data 4.31E-06 8.20E-07 No Data 9.76E-06 No Data 9.99E-06 Tc-99m 2.47E-10 6.98E-10 8.89E-09 No Data 1.06E-08 3.42E-10 4.13E-07 Tc-101 2.54E-10 3.66E-10 3.59E-09 No Data 6.59E-09 1.87E-10 1.1OE-21 Ru-103 1.85E-07 No Data 7.97E-08 No Data 7.06E-07 No Data 2.16E-05 Ru-105 1.54E-08 No Data 6.08E-09 No Data 1.99E-07 No Data 9.42E-06 Ru-106 2.75E-06 No Data 3.48E-07 No Data 5.31E-06 No Data 1.78E-04 Rh-105 1.22E-07 8.86E-08 5.83E-08 No Data 3.76E-07 No Data 1.41 E-05 Ag-110m 1.60E-07 1.48E-07 8.79E-08 No Data 2.91E-07 No Data 6.04E-05 Sb-124 2.81E-06 5.30E-08 1.11E-06 6.79E-09 No Data 2.18E-06 7.95E-05 Sb-125 2.23E-06 2.40E-08 4.48E-07 1.98E-09 No Data 2.33E-04 1.97E-05 Te-125m 2.68E-06 9.71E-07 3.59E-07 8.06E-07 1.09E-05 No Data 1.07E-05 Te-127m 6.77E-06 2.42E-06 8.25E-07 1.73E-06 2.75E-05 No Data 2.27E-05 Te-127 1.1OE-07 3.95E-08 2.38E-08 8.15E-08 4.48E-07 No Data 8.68E-06 Te-129m 1.15E-05 4.29E-06 1.82E-06 3.95E-06 4.80E-05 No Data 5.79E-05 Te-129 3.14E-08 1.18E-08 7.65E-09 2.41E-08 1.32E-07 No Data 2.37E-08 Te-131m 1.73E-06 8.46E-07 7.05E-07 1.34E-06 8.57E-06 No Data 8.40E-05 Te-131 1.97E-08 8.23E-09 6.22E-09 1.62E-08 8.63E-08 No Data 2.79E-09 9-41 VER 29 VEGP ODCM Table 9-14 (contd). Ingestion Dose Factors for the Adult Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 2.52E-06 1.63E-06 1.53E-06 1.80E-06 1.57E-05 No Data 7.71 E-05 1-130 7.56E-07 2.23E-06 8.80E-07 1.89E-04 3.48E-06 No Data 1.92E-06 1-131 4.16E-06 5.95E-06 3.41E-06 1.95E-03 1.02E-05 No Data 1.57E-06 1-132 2.03E-07 5.43E-07 1.90E-07 1.90E-05 8.65E-07 No Data 1.02E-07 1-133 1.42E-06 2.47E-06 7.53E-07 3.63E-04 4.31E-06 No Data 2.22E-06 1-134 1.06E-07 2.88E-07 1.03E-07 4.99E-06 4.58E-07 No Data 2.51 E-10 1-135 4.43E-07 1.16E-06 4.28E-07 7.65E-05 1.86E-06 No Data 1.31E-06 Cs-134 6.22E-05 1.48E-04 1.21E-04 No Data 4.79E-05 1.59E-05 2.59E-06 Cs-136 6.51E-06 2.57E-05 1.85E-05 No Data 1.43E-05 1.96E-06 2.92E-06 Cs-137 7.97E-05 1.09E-04 7.14E-05 No Data 3.70E-05 1.23E-05 2.11E-06 Cs-138 5.52E-08 1.09E-07 5.40E-08 No Data 8.01E-08 7.91E-09 4.65E-13 Ba-139 9.70E-08 6.91E-11 2.84E-09 No Data 6.46E-11 3.92E-11 1.72E-07 Ba-140 2.03E-05 2.55E-08 1.33E-06 No Data 8.67E-09 1.46E-08 4.18E-05 Ba-141 4.71E-08 3.56E-11 1.59E-09 No Data 3.31E-11 2.02E-11 2.22E-17 Ba-142 2.13E-08 2.19E-11 1.34E-09 No Data 1.85E-11 1.24E-11 3.OOE-26 La-140 2.50E-09 1.26E-09 3.33E-10 No Data No Data No Data 9.25E-05 La-142 1.28E-10 5.82E-11 1.45E-11 No Data No Data No Data 4.25E-07 Ce-141 9.36E-09 6.33E-09 7.18E-10 No Data 2.94E-09 No Data 2.42E-05 Ce-143 1.65E-09 1.22E-06 1.35E-10 No Data 5.37E-10 No Data 4.56E-05 Ce-144 4.88E-07 2.04E-07 2.62E-08 No Data 1.21E-07 No Data 1.65E-04 Pr-143 9.20E-09 3.69E-09 4.56E-10 No Data 2.13E-09 No Data 4.03E-05 Pr-144 3.01 E-11 1.25E-11 1.53E-12 No Data 7.05E-12 No Data 4.33E-18 Nd-147 6.29E-09 7.27E-09 4.35E-10 No Data 4.25E-09 No Data 3.49E-05 W-187 1.03E-07 8.61E-08 3.01E-08 No Data No Data No Data 2.82E-05 Np-239 1.19E-09 1.17E-10 6.45E-11 No Data 3.65E-10 No Data 2.40E-05 9-42 VER 29 9-42 VER 29 VEGP ODCM Table 9-15.External Dose Factors for Standing on Contaminated Ground Nuclide T. Body Skin H-3 0.00 0.00 C-14 0.00 0.00 Na-24 2.50E-08 2.90E-08 P-32 0.00 0.00 Cr-51 2.20E-10 2.60E-10 Mn-54 5.80E-09 6.80E-09 Mn-56 1.10E-08 1.30E-08 Fe-55 0.00 0.00 Fe-59 8.OOE-09 9.40E-09 Co-58 7.OOE-09 8.20E-09 Co-60 1.70E-08 2.OOE-08 Ni-63 0.00 0.00 Ni-65 3.70E-09 4.30E-09 Cu-64 1.50E-09 1.70E-09 Zn-65 4.OOE-09 4.60E-09 Zn-69 0.00 0.00 Br-83 6.40E-1 1 9.30E-1 1 Br-84 1.20E-08 1.40E-08 Br-85 0.00 0.00 Rb-86 6.30E-10 7.20E-10 Rb-88 3.50E-09 4.OOE-09 Rb-89 1.50E-08 1.80E-08 Sr-89 5.60E-13 6.50E-13 Sr-90 0.00 0.00 Nuclide T. Body Skin Sr-91 7.1OE-09 8.30E-09 Sr-92 9.OOE-09 1.OOE-08 Y-90 2.20E-12 2.60E-12 Y-91 m 3.80E-09 4.40E-09 Y-91 2.40E-11 2.70E- 11 Y-92 1.60E-09 1.90E-09 Y-93 5.70E-10 7.80E-10 Zr-95 5.OOE-09 5.80E-09 Zr-97 5.50E-09 6.40E-09 Nb-95 5.1OE-09 6.OOE-09 Mo-99 1.90E-09 2.20E-09 Tc-99m 9.60E-10 1.1OE-09 Tc-101 2.70E-09 3.OOE-09 Ru-103 3.60E-09 4.20E-09 Ru-105 4.50E-09 5.1OE-09 Ru-106 1.50E-09 1.80E-09 Rh-105 6.60E-10 7.70E-10 Ag-11im 1.80E-08 2.1OE-08 Sb-124 1.30E-08 1.50E-08 Sb-125 3.1OE-09 3.50E-09 Te-125m 3.50E-11 4.80E-11 Te-127m 1.10E-12 1.30E-12 Te-127 1.O0E-11 1.10E-11 Te-129m 7.70E-10 9.OOE-10 All values are in (mrem/h) per (pCi/m 2). They are obtained from Reference 3 (Table E-6), except as follows: Reference 2 (Table A-7) for Rh-105, Sb-124, and Sb-125.9-43 VER 29 VEGP ODCM Table 9-15 (contd).External Dose Factors for Standing on Contaminated Ground Nuclide T.Body Skin Te-129 7.10E-10 8.40E-10 Te-131m 8.40E-09 9.90E-09 Te-131 2.20E-09 2.60E-06 Te-132 1.70E-09 2.OOE-09 1-130 1.40E-08 1.70E-08 1-131 2.80E-09 3.40E-09 1-132 1.70E-08 2.OOE-08 1-133 3.70E-09 4.50E-09 1-134 1.60E-08 1.90E-08 1-135 1.20E-08 1.40E-08 Cs-134 1.20E-08 1.40E-08 Cs-136 1.50E-08 1.70E-08 Cs-137 4.20E-09 4.90E-09 Cs-138 2.1OE-08 2.40E-08 Ba-139 2.40E-09 2.70E-09 Ba-140 2.1OE-09 2.40E-09 Ba-141 4.30E-09 4.90E-09 Ba-142 7.90E-09 9.OOE-09 La-140 1.50E-08 1.70E-08 La-142 1.50E-08 1.80E-08 Ce-141 5.50E-10 6.20E-10 Ce-143 2.20E-09 2.50E-09 Ce-144 3.20E-10 3.70E-10 Pr-143 0.00 0.00 Pr-144 2.OOE-10 2.30E-10 Nd-147 1.00E-09 1.20E-09 W-187 3.1OE-09 3.60E-09 Np-239 9.50E-10 1.1OE-09 9-44 VER 29 VEGP ODCM CHAPTER 10 DEFINITIONS OF EFFLUENT CONTROL TERMS The terms defined in this chapter are used in the presentation of the above chapters.These terms are shown in all capital letters to indicate that they are specifically defined.10.1 TERMS SPECIFIC TO THE ODCM The following terms are used in the ODCM, but are not found in the Technical Specifications: | |||
ACTION(S)An ACTION shall be that part of a control that prescribes remedial measures required under designated conditions. | |||
BATCH RELEASE A BATCH RELEASE is the discharge of wastes of a discrete volume. Prior to sampling for analyses, each liquid batch shall be isolated and then thoroughly mixed by a method described in the ODCM to assure representative sampling.COMPOSITE SAMPLE A COMPOSITE SAMPLE is one which contains material from multiple waste releases, in which the quantity of sample is proportional to the quantity of waste discharged, and in which the method of sampling employed results in a specimen that is representative of the wastes released. | |||
Prior to analyses, all liquid samples that are to be aliquotted for a COMPOSITE SAMPLE shall be mixed thoroughly, in order for the COMPOSITE SAMPLE to be representative of the effluent release.When assessing the consequences of a waste release at the pre-release or post-release stage, the most recent available COMPOSITE SAMPLE results for the applicable release pathway may be used.CONTINUOUS RELEASE A CONTINUOUS RELEASE is the discharge of wastes of a non-discrete volume, e.g., from a volume within a system that has an input flow during the continuous release. To be representative of the quantities and concentrations of radioactive materials in CONTINUOUS RELEASES of liquid effluents, samples shall be collected in proportion to the rate of flow of the effluent stream or to the quantity of liquid waste discharged. | |||
FREQUENCY NOTATION The FREQUENCY NOTATION specified for the performance of surveillance requirements shall correspond to the intervals defined below, with a maximum allowable extension not to exceed 25% of the surveillance interval.9-45 VER 29 VEGP ODCM NOTATION FREQUENCY S (Once per shift) At least once per 12 hours.D (Daily) At least once per 24 hours.W (Weekly) At least once per 7 days.M (Monthly) | |||
At least once per 31 days.Q (Quarterly) | |||
At least once per 92 days.SA (Semi-annually) | |||
At least once per 184 days.R (Refueling) | |||
At least once per 18 months.S/U (Startup) | |||
Prior to each reactor startup.NA Not applicable. | |||
P (Prior) Completed prior to each release.GASEOUS WASTE PROCESSING SYSTEM A GASEOUS WASTE PROCESSING SYSTEM shall be any system designed and installed to reduce radioactive gaseous effluents by collecting Reactor Coolant System offgases from the Reactor Coolant System and providing for delay or holdup for the purpose of reducing the total radioactivity prior to release to the environment. | |||
LIQUID RADWASTE TREATMENT SYSTEM A LIQUID RADWASTE TREATMENT SYSTEM is any system designed and installed to reduce radioactive materials in liquid effluents by systematic collection, retention, and processing through filtration, evaporation, separation and/or ion exchange treatment. | |||
This system consists of at least one collection tank, one evaporator or demineralizer system, one post-treatment tank and associated components providing for treatment flow and functional control.MAJOR CHANGES TO RADIOACTIVE WASTE TREATMENT SYSTEMS For the purposes of the ODCM, MAJOR CHANGES TO RADIOACTIVE WASTE TREATMENT SYSTEMS include the following changes to such systems: (1) Major changes in process equipment, components, structures, or effluent monitoring instrumentation as described in the Final Safety Analysis Report (FSAR) or as evaluated in the Nuclear Regulatory Commission staffs Safety Evaluation Report (SER) (e.g., deletion of evaporators and installation of demineralizers); | |||
(2) Changes in the design of radwaste treatment systems that could significantly increase quantities of effluents released from those previously considered in the FSAR and SER;(3) Changes in system design which may invalidate the accident analysis as described in the SER (e.g., changes in tank capacity that would alter the curies released); | |||
or 9-46 VER 29 VEGP ODCM (4) Changes in system design that could potentially result in a significant increase in occupational exposure of operating personnel (e.g., use of temporary equipment without adequate shielding provisions). | |||
MEMBER(S) | |||
OF THE PUBLIC!A MEMBER OF THE PUBLIC means any individual except when that individual is receiving an occupational dose 2.This category may include persons who use portions of the site for recreational, occupational, or other purposes not associated with the plant.MINIMUM DETECTABLE CONCENTRATION The MINIMUM DETECTABLE CONCENTRATION (MDC) is defined, for purposes of the controls in this ODCM, as the smallest concentration of radioactive material in a sample that will yield a net count above system background and that will be detected with 95-percent probability, with only 5-percent probability of falsely concluding that a blank observation represents a "real" signal.For a particular measurement system, which may include radiochemical separation, the MDC for a given radionuclide is determined as follows (Reference 18): where: MDC = the a priori MINIMUM DETECTABLE CONCENTRATION (gCi per unit mass or volume).2.71 + 3.29 Rb t +MDC= ts E V -2.22 x 10 6 Y .e- At Rb = the background counting rate, or the counting rate of a blank sample, as appropriate (counts per minute).ts = the length of the sample counting period (minutes). | |||
tb = the length of the background counting period (minutes). | |||
E = the counting efficiency (counts per disintegration) | |||
V = the sample size (units of mass or volume).2.22 x 106 = the number of disintegrations per minute per ýtCi.Y = the fractional radiochemical yield, when applicable. | |||
The italicized terms in this definition, which are not otherwise used in this ODCM, shall have the definitions assigned to them by 10 CFR 20.1003.2 Except as delineated in other parts of 10 CFR chapter I.9-47 VER 29 VEGP ODCM X = the radioactive decay constant for the given radionuclide (h-').Values of X used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.At = for effluent samples, the elapsed time between the midpoint of sample collection and the time of counting (h); for environmental samples, the elapsed time between the end of sample collection and the time of counting (h).Typical values of E, V, Y, and At should be used in the calculation. | |||
It should be recognized that the MDC is defined as an a priori (before the fact) limit representing the capability of a measurement system, and not as an a posteriori (after the fact)limit for a particular measurement. | |||
PRINCIPAL GAMMA EMITTERS The PRINCIPAL GAMMA EMITTERS for which the MINIMUM DETECTABLE CONCENTRATION (MDC) limit applies include exclusively the following radionuclides: | |||
* For liquid radioactive effluents: | |||
Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, and Ce-141. Ce-144 shall also be measured, but with an MDC of 5 x 10.-6 LtCi/mL.* For gaseous radioactive effluents: | |||
In noble gas releases, Kr-87, Kr-88, Xe-133, Xe-133m, Xe-135, Xe-138; and in particulate releases, Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141, and Ce-144.* For environmental media: The gamma emitters specifically listed in Table 4-3.These lists do not mean that only these nuclides are to be considered. | |||
Other gamma peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Radioactive Effluent Release Report, the Annual Radiological Environmental Operating Report, or other applicable report(s). | |||
SITE BOUNDARY For the purpose of effluent controls defined in the ODCM, the SITE BOUNDARY shall be as shown in Figure 4-1.SOURCE CHECK A SOURCE CHECK shall be the qualitative assessment of channel response when the channel sensor is exposed to a source of increased radioactivity. | |||
9-48 VER 29 VEGP ODCM UNRESTRICTED AREA The UNRESTRICTED AREA shall be any area access to which is neither limited nor controlled by the licensee, or any area within the SITE BOUNDARY used for residential quarters or for industrial, commercial, institutional, and/or recreational purposes.VENTILATION EXHAUST TREATMENT SYSTEM The VENTILATION EXHAUST TREATMENT SYSTEM is any system designed and installed to reduce gaseous radioiodine or radioactive material in particulate form in effluents, by passing ventilation or vent exhaust gases through charcoal adsorbers and/or HEPA filters, for the purpose of removing iodines or particulates from the gaseous exhaust stream prior to the release to the environment. (Such a system is not considered to have any effect on any noble gas effluents). | |||
Engineered Safety Feature (ESF) atmospheric cleanup systems are not considered to be VENTILATION EXHAUST TREATMENT SYSTEM components. | |||
9-49 VER 29 VEGP ODCM 10.2 TERMS DEFINED IN THE TECHNICAL SPECIFICATIONS The following terms are defined in the Technical Specifications, Section 1.0. Because they are used throughout the Limits of Operation sections of the ODCM, they are presented here for convenience. | |||
In the event of discrepancies between the definitions below and those in the Technical Specifications, the Technical Specification definitions shall take precedence. | |||
CHANNEL CALIBRATION A CHANNEL CALIBRATION shall be the adjustment, as necessary, of the channel, such that it responds within the required range and accuracy to known values of input. The CHANNEL CALIBRATION shall encompass the entire channel including the required sensor, alarm, interlock, and/or trip functions and may be performed by any series of sequential, overlapping, or total channel steps, so that the entire channel is calibrated. | |||
CHANNEL CHECK A CHANNEL CHECK shall be the qualitative assessment of channel behavior during operation by observation. | |||
This determination shall include, where possible, comparison of the channel indication and/or status with other indications and/or status derived from independent instrument channels measuring the same parameter. | |||
CHANNEL OPERATIONAL TEST (COT)A CHANNEL OPERATIONAL TEST shall be the injection of a simulated signal into the channel as close to the sensor as practicable to verify operability of required alarm, interlock, and/or trip functions. | |||
The CHANNEL OPERATIONAL TEST shall include adjustments, as necessary, of the required alarm, interlock, and/or trip setpoints, so that the setpoints are within the required range and accuracy.DOSE EQUIVALENT 1-131 DOSE EQUIVALENT 1-131 shall be that concentration of 1-131 (ýtCi/g) which alone would produce the same thyroid dose as the quantity and isotopic mixture of 1-131, 1-132, 1-133, 1-134, and 1-135 actually present. The thyroid dose conversion factors used for this calculation shall be those listed in EPA Federal Guidance Report No. 11, "Limiting Values of Radionuclide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submersion, and Ingestion," EPA-520/1-88-020, September 1988.MODE (or OPERATIONAL MODE)An OPERATIONAL MODE shall correspond to any one inclusive combination of core reactivity condition, power level, average reactor coolant temperature, and reactor vessel head closure bolt tensioning specified in Section 1.0 of the Technical Specifications with fuel in the reactor vessel.9-50 VER 29 VEGP ODCM OPERABLE (or OPERABILITY) | |||
OPERABILITY exists when a system, subsystem, train, component or device is capable of performing its specified function(s), and when all necessary attendant instrumentation, controls, electrical power, cooling or seal water, lubrication or other auxiliary equipment that are required for the system, subsystem, train, component or device to perform its function(s) are also capable of performing their related support function(s). | |||
RATED THERMAL POWER RATED THERMAL POWER shall be a total reactor core heat transfer rate to the reactor coolant of 3565 MWt.THERMAL POWER THERMAL POWER shall be the total reactor core heat transfer rate to the reactor coolant.9-51 VER 29}} |
Latest revision as of 13:19, 17 March 2019
Text
{{#Wiki_filter:Edwin I. Hatch Nuclear Plant Joseph M. Farley Nuclear Plant Vogtle Electric Generating Plant Annual Radioactive Effluent Release Reports and Offsite Dose Calculation Manuals for 2013 Enclosure 3 Vogtle Annual Radioactive Effluent Release Report for 2013 SOUTHERN NUCLEAR COMPANY VOGTLE ELECTRIC GENERATING PLANT- UNITS 1 AND 2 NRC DOCKET NOS. 50-424 AND 50-425 FACILITY OPERATING LICENSE NOS. NPF-68 AND NPF-81 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR JANUARY 1, 2013 TO DECEMBER 31, 2013 Preparedby: OIL) 3d11#Reviewed byoltV7 4Y4 LA/Page 85 of 503 VOGTLE ELECTRIC GENERATING PLANT RADIOACTIVE EFFLUENT RELEASE REPORT -2013 TABLE OF CONTENTS TITLE PAGE SECTION 1.0 1.1 1.1.1 1.1.2 1.2 1.3 1.3.1 1.3.2 1.4 1.5 1.6 1.7 Table 1-1A Table 1-1 B Table 1-1C Liquid Effluents Regulatory Requirements Concentration Limits Dose Limits Effluent Concentration Limit (ECL)Measurements and Approximations of Total Radioactivity Total Radioactivity Determination Total Error Estimation Liquid Effluent Release Data Radiological Impact Due to Liquid Releases Liquid Effluents -Batch Releases Liquid Effluents -Abnormal Releases Liquid Effluents -Summation of All Releases Unit 1 (Quarters 1,2,3, and 4)Liquid Effluents -Summation of All Releases Unit 2 (Quarters 1,2,3, and 4)Liquid Effluents -Summation of All Releases Site (Quarters 1,2,3, and 4)Liquid Effluents -Unit I (Quarters 1,2,3, and 4)Liquid Effluents -Unit I (Quarters 1,2,3, and 4)Page 86 of 503 92 92 92 92 92 93 93 95 96 96 96 96 97 99 101 102 106 Table Table 1-2A 1-2B Table 1-2C Table 1-3A Table 1-3B Table 1-3C Table 1-4 Table 1-5A Table 1-5B Table 1-5C Table 1-6A Table 1-6A Table 1-6C 2.0 2.1 2.1.1 2.1.2 Liquid Effluents -Unit I (Quarters 1,2,3, and 4) 108 Doses to a Member of the Public Due to Liquid Releases Unit I (Quarters 1,2,3, and 4) 111 Doses to a Member of the Public Due to Liquid Releases Unit 2 (Quarters 1,2,3, and 4) 113 Doses to a Member of the Public Due to Liquid Releases Site (Quarters 1,2,3, and 4) 114 Minimum Detectable Concentration -Liquid 115 Liquid Effluents Batch Release Summary Unit I (Quarters 1,2,3, and 4) 116 Liquid Effluents Batch Release Summary Unit 2 (Quarters 1,2,3, and 4) 117 Liquid Effluents Batch Release Summary Site (Quarters 1,2,3, and 4) 118 Liquid Effluents Abnormal Release Summary Unit I (Quarters 1,2,3, and 4) 119 Liquid Effluents Abnormal Release Summary Unit I (Quarters 1,2,3, and 4) 121 Liquid Effluents Abnormal Release Summary Site (Quarters 1,2,3, and 4) 122 Gaseous Effluents 123 Regulatory Requirements 123 Dose Rate Limits 123 Air Doses Due to Noble Gases in Gaseous Releases 123 Page 87 of 503 2.1.3 2.2 2.2.1 2.2.2 2.2.2.1 2.2.2.2 2.2.2.3 2.2.3 2.3 2.4 2.5 2.6 Table 2-IA Table 2-1 B Table 2-I C Table 2-2A Table 2-2B Doses to a Member of the Public 123 Measurements and Approximations of Total Radioactivity 124 Sample Collection and Analysis 124 Total Quantities of Radioactivity, Dose Rates, and Cumulative Doses 125 Fission and Activation Gases 125 Radioiodines, Tritium and Particulate Releases 125 Gross Alpha Release 125 Total Error Estimation 126 Gaseous Effluent Release Data 127 Radiological Impact Due to Gaseous Releases 128 Gaseous Effluents -Batch Releases 128 Gaseous Effluents -Abnormal Releases 128 Gaseous Effluents Summation of All Releases Unit 1 (Quarters 1,2,3, and 4) 129 Gaseous Effluents Summation of All Releases Unit 2 (Quarters 1,2,3, and 4) 130 Gaseous Effluents Summation of All Releases Site (Quarters 1,2,3, and 4) 131 Gaseous Effluents Mixed Mode Releases Unit I (Quarters 1,2,3, and 4) 133 Gaseous Effluents Mixed Mode Releases Unit 2 (Quarters 1,2,3, and 4) 136 Page 88 of 503 Table 2-2C Table 2-3A Table 2-3B Table 2-3C Table 2-4A Table 2-4B Table 2-4C Table 2-5A Table 2-5B Table 2-5C Table 2-6 Table 2-7A Gaseous Effluents Mixed Mode Releases Site (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit I (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Gaseous Effluents Ground Level Releases Unit 2 (Quarters 1,2,3, and 4)Minimum Detectable Concentrations -Gaseous Gaseous Effluents -Batch Release Summary Unit 1 (Quarters 1,2,3, and 4)139 142 145 148 150 151 152 153 154 155 157 158 Page 89 of 503 Table 2-7B Table 2-7C Table 2-8A Table 2-8B Table 2-8C 3.0 3.1 3.1.1 3.1.2 3.2 Table 3-1 4.0 4.1 4.2 Table 4-1 5.0 5.1 5.2 Gaseous Effluents -Batch Release Summary Unit 2 (Quarters 1,2,3, and 4) 159 Gaseous Effluents -Batch Release Summary Site (Quarters 1,2,3, and 4) 160 Gaseous Effluents -Abnormal Release Summary Unit I (Quarters 1,2,3, and 4) 161 Gaseous Effluents -Abnormal Release Summary Unit 2 (Quarters 1,2,3, and 4) 162 Gaseous Effluents -Abnormal Release Summary Site (Quarters 1,2,3, and 4) 163 Solid Waste 164 Regulatory Requirements 164 Solid Radioactive Waste System 164 Reporting Requirements 164 Solid Waste Data 164 Solid Waste and Irradiated Fuel Shipments 165 Doses to Members of the Public Inside the Site Boundary 175 Regulatory Requirements 176 Demonstration of Compliance 176 Doses to Members of the Public Due to Activities Inside the Site Boundary 79 Total Dose from Uranium Fuel Cycle (40CFR190) 180 Regulatory Requirements 180 Demonstration of Compliance 180 Page 90 of 503 6.0 7.0 7.1 7.1.1 7.1.2 7.2 7.2.1 7.2.2 8.0 8.1 8.2 9.0 9.1 9.2 Appendix A Appendix B Appendix C Meteorological Data Program Deviations Inoperable Liquid or Gaseous Effluent Monitoring Instrumentation Regulatory Requirement Description of Deviations Tanks Exceeding Curie Content Limits Regulatory Requirements Description of Deviations Changes to the Vogtle Electric Generating Plant Offsite Dose Calculation Manual (ODCM)Regulatory Requirements Description of Changes Major Changes to Liquid, Gaseous, or Solid Radwaste Treatment Systems Regulatory Requirements Description of Major Changes Carbon-1 4 Corrected Reports VEGP ODCM Version 29 180 180 180 180 181 182 182 182 182 182 183 183 183 184 185 185 91 Page 91 of 503
1.0 Liquid
Effluents 1.1 Regulatory Requirements
1.1.1 Concentration
Limits In accordance with Technical Specification 5.5.4.b, the concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS shall be limited at all times to ten times the concentrations specified in 10 CFR 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 1 E-04 1 iCi/ml total activity.1.1.2 Dose Limits The dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive materials in liquid effluents released, from each unit, to UNRESTRICTED AREAS shall be limited as follows: a. During any calendar quarter to less than or equal to 1.5 mrems to the whole body and to less than or equal to 5 mrems to any organ, and b. During any calendar year to less than or equal to 3 mrems to the whole body and to less than or equal to 10 mrems to any organ.1.2 Effluent Concentration Limit (ECL)ECL values used for determining the allowable liquid radwaste release rates and concentrations for the principal gamma emitters, 1-131, tritium, Sr-89, Sr-90 and Fe-55 are taken from 10 CFR Part 20, Appendix B, Table 2, Column 2. A tolerance factor of up to 10 is utilized to allow flexibility in establishing practical monitor set points which can accommodate effluent releases at concentrations higher than the ECL values stated in 10 CFR 20, Appendix B, Table 2, Column 2.For dissolved or entrained noble gases in liquid radwaste, the ECL is 1 E-04 pCi/ml total activity.For gross alpha in liquid radwaste, the ECL is 2 E-09 ptCi/ml.For all the above radionuclides or categories of radioactivity, the overall ECL fraction is determined in accordance with 10 CFR Part 20, Appendix B. The method utilizing the ECL fraction to determine release rates and liquid radwaste effluent radiation monitor set points is described in Subsection 1.3 of this report.Page 92 of 503 1.3 1.3.1 Measurements and Approximations of Total Radioactivity Total Radioactivity Determination Prior to the release of any tank containing liquid radwaste, and following the required recirculation, samples are collected and analyzed in accordance with the Offsite Dose Calculation Manual (ODCM) Table 2-3"Radioactive Liquid Waste Sampling and Analysis Program". A sample from each tank which is planned for release is analyzed for principal gamma emitters, 1-131, and dissolved and entrained noble gases by gamma spectroscopy. Monthly and quarterly composites are prepared for analysis by extracting aliquots from each sample taken from the tanks, which are released. Liquid radwaste sample analyses are performed as follows: MEASUREMENT
- 1. Gamma Isotopic 2. Dissolved or entrained noble gases 3. Tritium 4. Gross Alpha 5. Sr-89 & Sr-90 FREQUENCY Each Batch Each Batch Monthly Composite Monthly Composite Quarterly Composite METHOD Gamma Spectroscopy with computerized data reduction.
Gamma Spectroscopy with computerized data reduction Distillation and liquid scintillation counting Gas flow proportional counting Chemical separation and gas flow proportional or scintillation counting Chemical separation and liquid scintillation counting 6. Fe-55 Quarterly Composite Page 93 of 503
1.3.1 Total
Radioactivity Determination cont'd Gamma isotopic measurements are performed using germanium detectors with a resolution of 2.1 keV or lower. A peak search of the resulting gamma ray spectrum is performed by the computer system. Energy and net count data for all significant peaks are determined, and a quantitative reduction or MDC calculation is performed. This ensures that the MDC's are met for the nuclides specified in ODCM Chapter 10 (i.e., Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-1 34, Cs-1 37, Ce-141 and Ce-144). The quantitative calculations, corrections for counting time, decay time, sample volume, sample geometry, detector efficiency, baseline counts, branching ratio and MDC calculations, are made based on the counts at the location in the spectrum where the peak for that radionuclide would be located, if present.Tritium, Gross Alpha, Sr-89, Sr-90, Fe-55 and Ni-63 are, in some cases, analyzed offsite.ECL fraction is determined using radionuclide concentrations of a tank planned for release, the most current results available for tritium, gross alpha, Sr-89, Sr-90, Fe-55 and Ni-63 and the corresponding ECL values.This ECL fraction is used, with appropriate safety factors, tolerance factors, and the minimum assured dilution stream flow to calculate maximum permissible release rates and a liquid effluent monitor setpoint. The monitor setpoint is calculated to assure that the limits of the Offsite Dose Calculation Manual (ODCM) are not exceeded.A monitor reading in excess of the calculated setpoint results in an automatic termination of the liquid radwaste discharge. Liquid effluent discharge is also automatically terminated if the dilution stream flow rate falls below the minimum assured dilution flow rate used in the setpoint calculations and established as a setpoint on the dilution stream flow monitor.Radionuclide concentrations, safety factors, dilution stream flow rate, and liquid effluent radiation monitor calibrations are entered into the computer and a pre-release printout is generated. If the release is not permissible, appropriate warnings will be displayed on the computer screen. If the release is permissible, it is approved by the Chemistry Department and sent to the Operations Department for approval and release. When the release is completed, the necessary data from the release (i.e., release volume, etc.) are provided by the Operations Department to the Chemistry Department. These data are input to the computer and a post-release printout is generated. The post release printout contains the actual release rates, release concentrations and quantities, actual dilution flow, and calculated doses to an individual. Typically achieved liquid effluent sample analyses minimum detectable concentrations are reported in Table 1-4.Page 94 of 503
1.3.2 Total
Error Estimation The total or maximum error associated with the effluent measurement includes the cumulative errors resulting from the total operation of sampling and measurement. Because it may be very difficult to assign error terms for each parameter affecting the final measurement, detailed statistical evaluation of error is not suggested. The objective should be to obtain an overall estimate of the error associated with measurements of radioactive materials released in effluents (Reference Reg. Guide 1.23 Rev 1). Total Error is calculated by the root mean square method. The root mean square value is the square root of the arithmetic mean (average) of the squares of the original values.a. Fission and activation total release was calculated from sample analysis results and release point flow rates.Sampling and statistical error 10%Counting Equipment Calibration 10%Tank Volumes and System Flow Rates 20%TOTAL ERROR 24.5%b. Total Tritium release was calculated from sample analysis results and release point volumes.Sampling and statistical errors 10%Counting equipment calibration 10%Tank volumes and system flow rate 20%TOTAL ERROR 24.5%c. Dissolved and entrained gases were calculated from sample analysis results and release point volumes.Sampling and statistical error 20%Counting equipment calibration 10%Tank volumes and system flow rate 20%TOTAL ERROR 30%d. Gross alpha radioactivity was calculated from sample analysis results and release point volumes.Sampling and statistical error 10%Counting Equipment calibration 10%Tank volumes and system flowrates 20%TOTAL ERROR 24.5%Page 95 of 503
1.3.2 Total
Error Estimation cont'd e. Volume of waste prior to dilution was calculated from level indicators on the tanks and pump discharge flow rates and times.Level Indicator error 10%Operator Interpretation of gauge 10%TOTAL ERROR 14%f. Volume of dilution water used was calculated from flow totalizers and pump discharge flow rates and times.Flow totalizer error 10%Operator interpretation of gauge 10%TOTAL ERROR 14%g. Gross alpha, Sr-89, Sr-90, Fe-55, Ni-63 and H-3 radioactivity has an additional error associated with sample compositing. Compositing sample error 5%1.4 Liquid Effluent Release Data Regulatory Guide 1.21 Rev. 1 Tables 2A and 2B are found in this report as Tables 1-1A, 1-1 B, 1-1 C, 1-2A, 1-2B and 1-2C. Data is presented on a quarterly basis as required by Regulatory Guide 1.21 Rev. 1 for all four quarters.1.5 Radiological Impact Due to Liquid Releases Doses to an individual due to radioactivity in liquid effluent were calculated in accordance with the Offsite Dose Calculation Manual.Results are presented in Table 1-3A for Unit 1 and 1-3B for Unit 2, for all four quarters.1.6 Liquid Effluents -Batch Releases Batch release information for liquid effluents is presented in Table 1-5A for Unit 1 and Table 1-5B for Unit 2.1.7 Liquid Effluents -Abnormal Releases There were no abnormal liquid releases during 2013.Page 96 of 503 Table 1-1A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents -Summation of All Releases Unit: 1 Starting: 1-Jan- 2013 Ending: 31-Dec-2013 Tyve of Effluent Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter A. Fission And Activation Products 1. Total Release (not including tritium, gases, alpha) Curies 8.92E-02 2.04E-02 1.66E-02 7.24E-03 2. Average diluted concentration during period uCi/mL 8.73E-09 5.78E-09 4.1OE-09 1.12E-09 3. Percent of Applicable Limit %* * * *B. Tritium 1. Total Release Curies 7.69E+02 4.33E+02 1.37E+02 3.41E+02 2. Average diluted Concentration during period uCi/mL 7.53E-05 1.22E-04 3.36E-05 5.26E-05 3. Percent of Applicable Umit %* * * *C. Dissolved and Entrained Gases 1. Total Release Curies 7.26E-03 4.18E-05 0.OOE+00 6.58E-06 2. Average diluted Concentration during period uCi/mL 7.11E-10 1.18E-11 0.OOE+00 1.02E-12 3. Percent of Applicable Limit %* * * *D: Gross Alpha Radioactivity
- 1. Total Release Curies 4.81E-04 O.OOE+00 O.OOE+00 0.OOE+00 E: Waste Vol Release (Pre-Dilution)
Liters 2.68E+07 2.95E+07 2.82E+07 3.14E+07 F. Volume of Dilution Water Used Liters 1.02E+10 3.50E+09 4.03E+09 6.44E+09* Applicable limits are expressed in terms of dose. See Tables 1-3A and 1-3B of this report.Page 97 of 503 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 1-4 for typical minimum detectable concentrations. Page 98 of 503 Table 1-1B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents -Summation Of All Releases Unit: 2 Startina: 1-Jan- 2013 Endina: 31-Dec-2013 Type of Effluent A. Fission And Activation Products 1. Total Release (not including tritium, gases, alpha)2. Average diluted concentration during period 3. Percent of Applicable Limit Ilnii**I CT Mlmml4=r I)Mf fmm=lr*gr'ADf r% A M r AT- Monmmgr M Curies uCi/mL 1.21E-02 1.50E-09 8.18E-03 2.34E-09 2.71E-03 6.76E-10*¢1.94E-03 3.24E-10 B. Tritium 1. Total Release Curies 6.72E+01 6.95E+01 2. Average diluted Concentration during period uCi/mL 8.34E-06 1.99E-05 3. Percent of Applicable Limit %* *C. Dissolved and Entrained Gases 1. Total Release Curies 3.35E-04 5.13E-06 2. Average diluted Concentration during period uCi/mL 4.16E-11 1.47E-12 3. Percent of Applicable Limit %* *D: Gross Alpha Radioactivity
- 1. Total Release Curies O.OOE+00 0.OOE+00 E: Waste Vol Release (Pre-Dilution)
Liters 3.45E+07 4.55E+07 F. Volume of Dilution Water Used Liters 8.02E+09 3.44E+09* Applicable limits are expressed in terms of dose. See Tables 1-3A and 1-3B of this report.3.85E+01 9.59E-06 , O.OOE+00 O.OOE+00 0.OOE+00 4.18E+07 3.97E+09 4.70E+01 7.86E-06 O.OOE+OO O.OOE+0O O.OOE+OO 4.37E+07 5.94E+09 Page 99 of 503 If Not Detected,. Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 1-4 for typical minimum detectable concentrations. Page 100 of 503 Table 1-1C VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents -Summation Of All Releases Unit: Site Starting: 1-Jan- 2013 Endinq: 31-Dec-2013 TvYe of Effluent Units 1ST Quarter 2ND Ouarter 3RD Ouarter 4TH Ouarter A. Fission And Activation Products 1. Total Release (not including tritium, gases, alpha) Curies 1.01E-01 2.86E-02 1.94E-02 9.18E-03 2. Average diluted concentration during period uCi/mL 5.54E-09 4.07E-09 2.40E-09 7.37E-10 3. Percent of Applicable Limit %* * * *B. Tritium 1. Total Release Curies 8.37E+02 5.02E+02 1.75E+02 3.88E+02 2. Average diluted Concentration during period uCi/mL 4.58E-05 7.15E-05 2.17E-05 3.11E-05 3. Percent of Applicable Limit % * * * *C. Dissolved and Entrained Gases 1. Total Release Curies 7.60E-03 4.70E-05 O.OOE+00 6.58E-06 2. Average diluted Concentration during period uCi/mL 4.16E-10 6.69E-12 O.OOE+00 5.29E-13 3. Percent of Applicable Limit % * * * *D: Gross Alpha Radioactivity
- 1. Total Release Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 E: Waste Vol Release (Pre-Dilution)
Liters 6.13E+07 7.50E+07 7.OOE+07 7.51E+07 F. Volume of Dilution Water Used Liters 1.82E+10 6.95E+09 8.OOE+09 1.24E+10* Applicable limits are expressed in terms of dose. See Tables 1-3A and 1-3B of this report.Page 101 of 503 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 1-4 for typical minimum detectable concentrations. Table 1-2A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents Unit: 1 Startina: 1-Jan- 2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Fission & Activation Products Fe-55 Total For Period Tritium H-3 Dissolved And Entrained Gases No Nuclides Found Gross Alpha Radioactivity No Nuclides Found Curies Curies Curies Curies Curies 1.09E-03 1.09E-03 3.18E-02 O.OOE+00 O.OOE+00 1.64E-03 1.64E-03 4.13E-02 O.OOE+O0 O.OOE+00 5.87E-04 5.87E-04 4.15E-02 O.OOE+00 O.OOE+00 3.76E-04 1.27E-01 0.OOE+00 0.OOE+00*Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable concentrations. Page 102 of 503 Table 1-2A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents Unit: 1 Starting: 1-Jan- 2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released Fission & Activation Products Co-58 Co-60 Cr-51 Fe-55 1-131 1-132 Mn-54 Nb-95 Ni-56 Ni-63 Sr-89 Sr-90 W-187 Ba-133 Cs-134 Cs-137 Rh-105 Ru-105 Ru-106 Sb-122 Sb-124 Sb-125 Sb-126 Te-132 Sn-117M Te-125M Te-129M Total For Period Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies 5.69E-03 1.55E-03 7.33E-04 2.46E-02 9.94E-05 7.27E-05 3.64E-04 6.01E-06 9.91E-06 2.21E-03 2.09E-05 4.96E-06 O.OOE+00 6.72E-05 1.90E-05 2.48E-04 2.04E-05 4.81E-06 O.OOE+00 3.18E-05 6.17E-05 3.79E-02 3.79E-05 7.81E-05 O.OOE+00 1.36E-02 7.87E-04 8.81E-02 2.56E-03 6.43E-04 0.OOE+00 7.85E-03 0.OOE+0O 0.OOE+O0 1.83E-05 2.58E-06 O.OOE+00 6. 13E-03 1.66E-06 6.1 IE-07 7.26E-06 0.OOE+OO 4. 18E-05 4.36E-04 0.OOE+00 0.OOE+00 8.41E-06 0.OOE+0O 4-33E-06 5. 34E-04 0.OOE+00 0.OOE+00 0.OOE+O0 5.37E-04 0.OOE+00 1.88E-02 2.33E-03 6.09E-04 0.OOE+0O 4.30E-03 0.OOE+00 0.OOE+00 3.48E-05 0.OOE+00 0.OOE+00 4.69E-03 9.36E-07 1 .47E-06 0.OOE+00 0.OOE+00 4. 57E-05 3.34E-04 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 1. 16E-03 0.OOE+O0 0.OOE+00 0.OOE+O0 2.57E-03 0.OOE+O0 1.61E-02 2.03E-04 6.04E-04 0.OOE+00 8.38E-04 0.OOE+00 0.OOE+00 1.06E-05 0.OOE+00 8.40E-06 7.93E-04 0. OOE+00 2.64E-07 0.OOE+00 0.OOE+0O 1.49E-06 1.14E-04 O.OOE+00 O.OOE+00 O.OOE+0O 0.OOE+0O 0.OOE+00 3.84E-05 0.OOE+OO 0.OOE+0O 1.66E-06 4.25E-03 0.OOE+00 6.86E-03*Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable Page 103 of 503 concentrations. Page 104 of 503 Table 1-2A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents Unit: 1 Startinga: 1-Jan- 2013 Ending: 31-Dec-2013 Batch Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Nuclides Released Tritium H-3 Dissolved And Entrained Gases Ar-41 Xe-127 Xe-133 Xe-135 Xe-133M Total For Period Gross Alpha Radioactivity G-Alpha Curies Curies Curies Curies Curies Curies Curies 7.69E+02 O.OOE+00 1.06E-05 6.73E-03 4.71E-04 5.53E-05 7.26E-03 4.33E+02 3. 19E-06 0.OOE+00 3.86E-05 0.OOE+00 0.OOE+00 4.18E-O5 1.37E+02 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 3.41E+02 0.OOE+00 0.OOE+O0 6.58E-06 0.OOE+00 a.OOE+00 6.5SE-06 Curies O.OOE+O0 O.OOE+00 O.OOE+O0 O.OOE+00 Page 105 of 503
- Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 1-4 for typical minimum detectable concentrations.
Table 1-2B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents Unit: 2 Startina: 1-Jan- 2013 Ending: 31-Dec-2013 Continuous Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Nuclides Released Fission & Activation Products No Nuclides Found Tritium H-3 Dissolved And Entrained Gases No Nuclides Found Gross Alpha Radioactivity No Nuclides Found Curies Curies Curies Curies 0.OOE+00 3.88E-02 0.OOE+00 0.OOE+00 0.OOE+00 1.17E-01 0.OOE+00 0.OOE+00 0.OOE+00 2.92E-02 0.OOE+00 0.OOE+00 O.OOE+00 7.56E-02 O.OOE+00 O.OOE+00 Page 106 of 503
- Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 1-4 for typical minimum detectable concentrations.
Table 1-2B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents Unit: 2 Startina: 1-Jan- 2013 Endinq: 31-Dec-2013 Batch Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Nuclides Released Fission & Activation Products Co-58 Co-60 Cr-51 Fe-55 1-131 Mn-54 Nb-95 Ni-56 Ni-63 Sr-89 W-187 Cs-134 Cs-137 Sb-122 Sb-124 Sb-125 Sb-126 Te-132 Te-125M Te-129M Total For Period Tritium H-3 Dissolved And Entrained Gases Ar-41 Xe-127 Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies Curies 1.12E-03 4.35E-04 1.04E-04 1.28E-03 1.65E-05 4.99E-05 0.OOE+00 7.27E-06 8.73E-04 5.49E-06 0.OOE+00 0.OOE+00 7.08E-05 5.62E-06 3.47E-05 4.87E-03 9.55E-06 5.28E-06 3.09E-03 8.88E-05 1.21E-02 6.71E+01 O.OOE+00 1.06E-05 1.57E-03 6.04E-04 0.OOE+00 1.37E-03 0.OOE+00 3.30E-05 1.24E-05 0.OOE+00 1. 12E-03 5.92E-06 6. 17E-06 2.25E-04 8.29E-04 0.OOE+00 0.OOE+00 5.OOE-04 0.OOE+00 0.OOE+00 1.91E-03 0.OOE+0O 8.18E-03 6.94E+01 5. 13E-06 0.OQE+00 4.96E-04 2. 16E-04 0.OOE+00 5.96E-06 0.OOE+00 1.05E-06 0.OOE+O0 8.57E-07 2.0 1E-04 0.OOE+00 0.OOE+00 2.74E-05 1.42E-04 0.OOE+00 9.98E-06 8.99E-04 0.OOE+00 0.OOE+00 7.15E-04 0.OOE+00 2.71E-03 3.85E+01 0.OOE+0Q 0.OOE+00 4.03E-05 6.37E-05 0.OOE+O0 1. 15E-04 0.OOE+00 0.OOE+00 O.OOE+00 2.40E-06 6.41E-05 0.OOE+O0 0.OOE+00 1.57E-06 2.39E-05 0.OOE+00 0.OOE+00 1.11E-05 0.OOE+00 0.OOE+00 1.62E-03 0.OOE+O0 IL.94E-03 4. 70E+01 0.OOE+00 0.OOE+O0 Page 107 of 503 Xe-133 Curies 3.23E-04 O.OOE+00 O.OOE+00 O.OOE+00 Xe-135 Curies 1.77E-06 O.OOE+00 O.OOE+00 O.OOE+00 Total For Period Curies 3.35E-04 5.13E-06 O.OOE+00 0.OOE+00 Gross Alpha Radioactivity No Nuclides Found Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00*Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable concentrations. Table 1-2C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents Unit: Site Starting: 1-Jan- 2013 Endina: 31-Dec-2013 Continuous Mode Nuclides Released Fission & Activation Products Fe-55 Total For Period Tritium H-3 Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Curies Curies Curies 1.09E-03 7.06E-02 1.64E-03 1.58E-01 5.87E-04 7.07E-02 3.76E-04 2.02E-01 Dissolved And Entrained Gases No Nuclides Found Gross Alpha Radioactivity No Nuclides Found Curies Curies 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 Page 108 of 503
- Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable concentrations.
Table 1-2C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents Unit: Site Startina: 1-Jan- 2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Fission & Activation Products Co-58 Curies 6.81E-03 4.12E-03 2.82E-03 2.43E-04 Co-60 Curies 1.98E-03 1.25E-03 8.25E-04 6.67E-04 Cr-51 Curies 8.37E-04 O.OOE+00 O.00E+00 O.OOE+00 Fe-55 Curies 2.58E-02 9.22E-03 4.31E-03 9.53E-04 1-131 Curies 1.16E-04 O.OOE+00 O.OOE+00 O.OOE+00 1-132 Curies 7.27E-05 O.OOE+00 O.OOE+00 O.OOE+00 Mn-54 Curies 4.14E-04 5.12E-05 3.59E-05 1.06E-05 Nb-95 Curies 6.01E-06 1.49E-05 0.O0E+00 0.OOE+00 Ni-56 Curies 1.72E-05 O.OOE+00 8.57E-07 1.08E-05 Ni-63 Curies 3.08E-03 7.25E-03 4.89E-03 8.57E-04 Sr-89 Curies 2.64E-05 7.58E-06 9.36E-07 0.OOE+00 Sr-90 Curies 4.96E-06 6.11E-07 1.47E-06 2.64E-07 W-187 Curies O.OOE+00 1.34E-05 O.OOE+00 0.OOE+00 Ba-133 Curies 6.72E-05 O.OOE+00 O.OOE+00 O.OOE+00 Cs-134 Curies 1.90E-05 2.67E-04 7.31E-05 3.05E-06 Cs-137 Curies 3.19E-04 1.27E-03 4.75E-04 1.38E-04 Rh-105 Curies 2.04E-05 O.OOE+00 O.OOE+00 O.OOE+00 Ru-105 Curies 4.81E-06 O.OOE+00 O.OOE+00 0.OOE+00 Ru-106 Curies 0.OOE+00 8.41E-06 0.OOE+00 O.OOE+00 Sb-122 Curies 3.74E-05 0.OOE+00 0.OOE+00 O.OOE+00 Sb-124 Curies 9.65E-05 4.33E-06 9.98E-06 O.OOE+00 Sb-125 Curies 4.28E-02 1.03E-03 2.05E-03 4.95E-05 Page 109 of 503 Sb-126 Curies 4.74E-05 0.OOE+00 O.OOE+00 0.OOE+00 Te-132 Curies 8.34E-05 0.OOE+00 O.OOE+00 O.OOE+00 Sn-117M Curies O.OOE+00 0.OOE+00 0.OOE+00 1.66E-06 Te-125M Curies 1.66E-02 2.45E-03 3.28E-03 5.87E-03 Te-129M Curies 8.75E-04 O.OOE+00 0.OOE+00 O.OOE+00 Total For Period Curies 1.OOE-01 2.70E-02 1.88E-02 8.80E-03*Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable concentrations. Table 1-2C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents Unit: Site Startinag 1-Jan- 2013 Endina: 31-Dec-2013 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Tritium H-3 Curies 8.37E+02 5.02E+02 1.75E+02 3.87E+02 Dissolved And Entrained Gases Ar-41 Curies O.OOE+00 8.32E-06 O.OOE+00 0.OOE+00 Xe-127 Curies 2.12E-05 O.OOE+00 O.OOE+00 0.OOE+00 Xe-133 Curies 7.05E-03 3.86E-05 O.OOE+00 6.58E-06 Xe-135 Curies 4.73E-04 0.OOE+00 O.OOE+00 0.OOE+00 Xe-133M Curies 5.53E-05 O.OOE+00 0.OOE+00 O.OOE+00 Total For Period Curies 7.60E-03 4.70E-05 0.OOE+00 6.58E-06 Gross Alpha Radioactivity G-Alpha Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Page 110 of 503
- Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable concentrations.
Table 1-3A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses to a member of the public due to Liquid Releases Unit: 1 Startina: 1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Liver Lung Thyroid Total Body ODCM Lmt 5.OOE+O0 5.OOE+O0 5.OOE+O0 5.OOE+O0 5.OOE+O0 5.OOE+O0 1.50E+00 Units mRem mRem mRem mRem mRem mRem mRem 1ST Qtr 3.09E-03 1.75E-02 1.38E-02 1.33E-02 5.61E-02 1. 15E-02 1.26E-02%/o ODCM 6.18E-02 3.51E-01 2.76E-01 2.66E-01 1.12E+00 2.31E-01 8.42E-01 2ND Qtr 8.21E-03 1.34E-02 1.46E-02 1.87E-02 1.45E-02 1.28E-02 1.66E-02%/o ODCM 1.64E-01 2.68E-01 2.93E-01 3.73E-01 2.90E-01 2.55E-01 1.11E+00 3RD Qtr 6.16E-03 4.47E-03 5.38E-03 8.12E-03 6.88E-03 3.34E-03 6.51E-03%/a ODCM 1.23E-01 8.94E-02 1.08E-01 1.62E-01 1.38E-01 6.69E-02 4.34E-01 4TH Qtr 1.60E-03 9.57E-03 9.85E-03 9.97E-03 8.92E-03 8.73E-03 9.51E-03 0/a ODCM 3.19E-02 1.91E-01 1.97E-01 1.99E-01 1.78E-01 1.75E-01 6.34E-0 1 Cumulative Doses per Year Organ ODCM Lmt Units 1.OOE+01 mRem 1.00E+01 mRem Year to Ending Date% ODCM Receptor Limit Bone GI-Lli 1.91E-02 4.49E-02 1.91E-01 Maximum Individual Liquid 4.49E-01 Maximum Individual Liquid Liquid Effluent Organ Annual Liquid Effluent Organ Annual Page 11 of 503 Kidney Liver Lung Thyroid Total Body 1.00E+01 1.00E+01 1.00E+01 1.0OE+01 3.OOE+00 mRem mRem mRem mRem mRem 4.37E-02 5.01E-02 8.64E-02 3.64E-02 4.53E-02 4.37E-01 5.01E-01 8.64E-01 3.64E-01 1.51E+00 Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual Uquid Effluent TB Annual Page 112 of 503 Table 1-3B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses to a member of the public due to Liquid Releases Unit: 2 Startina: 1-Jan- 2013 Ending: 31-Dec-2013 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Liver Lung Thyroid Total Body ODCM Lint Units 1ST Qtr 0/b ODCM 2ND Qtr % ODCM 3RD Qtr %/o ODCM 4TH Qtr % ODCM 5.OOE+00 5.OOE+00 5.OOE+00 5.OOE+00 5.OOE+00 5.OOE+00 1.50E+00 mRem mRem mRem mRem mRem mRem mRem 7.11E-04 1.82E-03 1.38E-03 1.33E-03 6.51E-03 9.41E-04 1. 18E-03 1.42E-02 3.63E-02 2.76E-02 2.66E-02 1.30E-01 1.88E-02 7.87E-02 9.40E-03 3.23E-03 7.03E-03 1.50E-02 4.66E-03 2.04E-03 1. 1OE-02 1.88E-01 6.46E-02 1.41E-01 3.OOE-01 9.32E-02 4.07E-02 7.35E-01 1.65E-03 1.53E-03 1.96E-03 3.29E-03 3.84E-03 1. 1OE-03 2.61E-03 3.29E-02 3.07E-02 3.91E-02 6.59E-02 7.68E-02 2.20E-02 1.74E-01 3.44E-04 1.70E-03 1.79E-03 1.67E-03 1.40E-03 1.36E-03 1.55E-03 6.88E-03 3.40E-02 3.57E-02 3.34E-02 2.80E-02 2.72E-02 1.03E-01 Cumulative Doses per Year Organ ODCM Lmt Units Year to Ending Date%/a ODCM Receptor Limit Bone GI-Lli Kidney Uver Lung Thyroid Total Body 1.00E+01 1.00E+01 1.OOE+01 1.00E+01 1.00E+01 1.00E+01 3.OOE+00 mRem mRem mRem mRem mRem mRem mRem 1.21E-02 8.28E-03 1.21E-02 2.13E-02 1.64E-02 5.44E-03 1.64E-02 1.21E-01 8.28E-02 1.21E-01 2.13E-01 1.64E-01 5.44E-02 5.45E-01 Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual ULquid Maximum Individual ULquid Maximum Individual Liquid ULquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual ULquid Effluent Organ Annual ULquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent TB Annual Page 113 of 503 Table 1-3C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses to a member of the public due to Liquid Releases Unit: Site Starting: 1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Liver Lung Thyroid Total Body ODCM Lmt Units 1ST Qtr % ODCM 2ND Qtr %/o ODCM 3RD Qtr 0/o ODCM 4TH Qtr 0/b ODCM 5.OOE+00 5.OOE+00 5.0OEO00 5.OOE+00 5.OOE+OO 5.OOE+QO 1.50E+00 mRem mRem mRem mRem mRem mRem mRem 3.80E-03 1.94E-02 1.52E-02 1.47E-02 6.26E-02 1.25E-02 1.38E-02 7.61E-02 3.87E-01 3.04E-01 2.93E-01 1.25E+00 2.49E-01 9.21E-01 1.76E-02 1.66E-02 2.17E-02 3.36E-02 1.92E-02 1.48E-02 2.77E-02 3.52E-01 3.32E-01 4.33E-01 6.73E-01 3.84E-01 2.96E-01 1.84E+00 7.81E-03 6.OOE-03 7.34E-03 1.14E-02 1.07E-02 4.44E-03 9.12E-03 1.56E-01 1.20E-01 1.47E-01 2.28E-01 2. 14E-01 8.89E-02 6.08E-01 1.94E-03 1. 13E-02 1. 16E-02 1. 16E-02 1.03E-02 1.01E-02 1.11E-02 3.88E-02 2.25E-01 2.33E-01 2.33E-01 2.06E-0 1 2.02E-01 7.37E-01 Cumulative Doses per Year Organ ODCM Lmt Units Year to Ending Date% ODCM Receptor Limit Bone GI-Lli Kidney Liver Lung Thyroid Total Body 1.OOE+O1 1.OOE+01 1.0OE+01 1.OOE+O1 1.OOE+01 1.OOE+O1 3.OOE+00 mRem mRem mRem mRem mRem mRem mRem 3.12E-02 5.32E-02 5.58E-02 7.14E-02 1.03E-01 4.18E-02 6.16E-02 3.12E-01 5.32E-01 5.58E-01 7.14E-01 1.03E+00 4.18E-01 2.05E+00 Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Maximum Individual Liquid Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent Organ Annual Liquid Effluent TB Annual Page 114 of 503 Table 1-4 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 MINIMUM DETECTABLE CONCENTRATIONS-LIQUID SAMPLE ANALYSES Starting: 1-Jan-2013 Ending: 31-Dec-2013 The values in this table represent a priori Minimum Detectable Concentrations (MDC) that are typically achieved in laboratory analyses of liquid radwaste samples.RADIONUCLIDE Mn-54 Fe-59 Co-58 Co-60 Zn-65 Mo-99 Cs-134 Cs-137 Ce-141 Ce-144 1-131 Xe-133 Xe-135 Fe-55 Sr-89 Sr-90 H-3 Gross Alpha MDC 2.73E-08 8.33E-08 3.78E-08 6.76E-08 1.32E-07 4.31E-07 3.06E-08 4.51E-08 6.99E-08 2.95E-07 5.97E-08 9.11E-08 4.27E-08 1.00E-06 5.OOE-08 7.OOE-09 2.OOE-06 7.OOE-08 UNITS pCi/ml 1 tCi/ml pCi/ml jiCi/ml tCi/ml iCi/ml ,tCi/ml pCi/ml pCi/ml 1Ci/ml tCi/ml 1 Ci/ml pCi/ml tCi/ml pCi/ml tCi/mI pCi/ml pCi/ml Page 115 of 503 Table 1-5A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents -Batch Release Summary Unit: 1 Startina: 1-Jan- 2013 Ending: 31 -Dec-2013 Liquid Release Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter Year Totals 1. Number of batch releases 43 22 12 18 95 2. Total time period for Batch releases (Minutes) 1.52E+04 3.80E+03 1.58E+03 6.25E+03 2.68E+04 3. Maximum time period for a batch release (Minutes) 1.08E+03 6.08E+02 3.41E+02 9.08E+02 1.08E+03 4. Average time period for a batch release (Minutes) 3.53E+02 1.73E+02 1.31E+02 3.47E+02 2.82E+02 5. Minimum time period for a batch release (Minutes) 6.50E+01 6.10E+01 4.90E+01 6.OOE+01 4.90E+01 6. Average stream flow during periods of release of liquid effluent into a flowing stream * (CFS) 5863 6705 17736 7121 9356*Average river flowrate taken from USGS Monitoring Station 02197500, Savannah River at Burton's Ferry Bridge near Millhaven, Ga. 32 miles downstream of Plant Vogtle.Page 116 of 503 Table 1-5B i ; ;A n i I"n;4**t4UJ .ij fl~.~UC~a .* *Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents -Batch Release Summary Unit: 2 Startina" 1-Jan- 2013 Ending: 31-Dec-2013 1ST Quarter 2ND Quarter 3RD Quarter 15 18 7 es) 2.76E+03 2.96E+03 9.OOE+02 es) 7.60E+02 3.48E+02 2.83E+02 es) 1.84E+02 1.64E+02 1.29E+02 tes) 5.20E+01 4.70E+01 6.OOE+01 4TH Quarter 1. Number of batch releases 2. Total time period for Batch releases 3. Maximum time period for a batch release 4. Average time period for a batch release 5. Minimum time period for a batch release 6. Average stream flow during periods of release of liquid effluent into a flowing stream *(Minut (Minut (Minut ( Minut 6 1.21E+03 4.41E+02 2.02E+02 8.40E+01 7121 Year Totals 46 7.16E+03 7.60E+02 1.70E+02 4.70E+01 9356 ( CFS )5863 6705 17736*Average river flowrate taken from USGS Monitoring Station 02197500, Savannah River at Burton's Ferry Bridge near Millhaven, Ga. 32 miles downstream of Plant Vogtle.Page 117 of 503 Table 1-5C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents -Batch Release Summary Unit: Site Startina: 1-Jan- 2013 Ending: 31-Dec-2013 I ;n..;A D0M ec IIn;i*I CT NimbrM Tin% fmm:rigr'A F' rlmm or 1. Number of batch releases 2. Total time period for Batch releases 3. Maximum time period for a batch release 4. Average time period for a batch release 5. Minimum time period for a batch release 6. Average stream flow during periods of release of liquid effluent into a flowing stream *(Minutes)(Minutes)(Minutes)(Minutes)(CFS )55 1.73E+04 1.08E+03 3.14E+02 5.20E+01 5863 40 6.75E+03 6.08E+02 1.69E+02 4.70E+01 6705 19 2.48E+03 3.41E+02 1.30E+02 4.90E+01 17736 4TH Ouarter 24 7.46E+03 9.08E+02 3.11E+02 6.OOE+01 7121 Year Totals 138 3.40E+04 1.08E+03 2.46E+02 4.70E+01 9356*Average river flowrate taken from USGS Monitoring Station 02197500, Savannah River at Burton's Ferry Bridge near Millhaven, Ga. 32 miles downstream of Plant Vogtle.Page 118 of 503 Table 1-6A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT- 2013 Liquid Effluents -Abnormal Release Summary Unit: 1 Startina: 1-]an- 2013 Ending: 31-Dec-2013 I in,,irl Ilnitc I QT nfrtar?NIl f.lmirher 2ND n"n er a 1. Number of Releases 2. Total Time For All Releases 3. Maximum Time For A Release 4. Average Time For A Release 5. Minimum Time For A Release 6. Total activity for all releases (Minutes)(Minutes)(Minutes)(Minutes)( Curies )0 0.OOE÷00 0.OOE+00 0.OOE+00 0.OOE+OO 0.OOE+00 0 O.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 3RD Ouarter 0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 4TH Ouarter 0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Year Totals 0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00*Average river flowrate taken from USGS Monitoring Station 02197500, Savannah River at Burton's Ferry Bridge near Millhaven, Ga. 32 miles downstream of Plant Vogtle.Page 119 of 503 Page 120 of 503 Table 1-6B VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents -Abnormal Release Summary Unit: 2 Startina: 1-Jan- 2013 Endinn: 31-Dec-2013 Liouid Releases Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter Year Totals 1. Number of Releases 0 0 0 0 0 2. Total Time For All Releases (Minutes) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3. Maximum Time For A Release (Minutes) 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 4. Average Time For A Release (Minutes) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5. Minimum Time For A Release (Minutes) 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6. Total activity for all releases (Curies) 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00*Average river flowrate taken from USGS Monitoring Station 02197500, Savannah River at Burton's Ferry Bridge near Millhaven, Ga. 32 miles downstream of Plant Vogtle.Page 121 of 503 Table 1-6C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Liquid Effluents -Abnormal Release Summary Unit: Site Startina: 1-lan- 2013 Endina: 31-Dec-2013 l .;Annmi D I I n;#-I CT Ml.m m ýr ,11n fmm=r+A'40n nm 1. Number of Releases 2. Total Time For All Releases 3. Maximum Time For A Release 4. Average Time For A Release 5. Minimum Time For A Release 6. Total activity for all releases (Minutes)(Minutes)(Minutes)(Minutes)( Curies )0 0.OOE+00 O.OOE+00 0.OOE+00 0.O0E+00 0.aOE+00 0 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+0O 0.OOE+00 0 0.OOE+00 0.OOE+O0 0.OOE+00 O.OOE+00 0.OOE+00 4TH Ouarter 0 0.OOE+00 0.OOE+0O 0.OOE+00 O.OOE÷0O 0.OOE+00 Year Totals 0 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+0O0 O.OOE+00*Average river flowrate taken from USGS Monitoring Station 02197500, Savannah River at Burton's Ferry Bridge near Millhaven, Ga. 32 miles downstream of Plant Vogtle.Page 122 of 503
2.0 Gaseous
Effluents 2.1 Regulatory Requirements The ODCM Specifications presented in this section are for Unit 1 and Unit 2.2.1.1 Dose Rate Limits The dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the SITE BOUNDARY shall be limited to the following:
- a. For noble gases, Less than or equal to 500 mrems/yr.
to the whole body and less than or equal to 3000 mrems/yr. to the skin and, b. For Iodine-1 31, for Iodine-1 33, for tritium and for all radionuclides in particulate form with half lives greater than 8 days: Less than or equal to 1500 mrems/yr. to any organ.2.1.2 Air Doses Due to Noble Gases in Gaseous Releases The air dose due to noble gases released in gaseous effluents, from each unit, to areas at and beyond the SITE BOUNDARY shall be limited to the following:
- a. During any calendar quarter: Less than or equal to 5 mrads for gamma radiation and less than or equal to 10 mrads for beta radiation, and b. During any calendar year: Less than or equal to 10 mrads for gamma radiation and less than or equal to 20 mrads for beta radiation.
2.1.3 Doses
to a Member of the Public The dose to a MEMBER OF THE PUBLIC from Iodine-131, Iodine-133, tritium and all radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents released, from each unit, to areas at and beyond the SITE BOUNDARY shall be limited to the following.
- a. During any calendar quarter: Less than or equal to 7.5 mrems to any organ.b. During any calendar year: Less than or equal to 15 mrems to any organ.Page 123 of 503
2.2 Measurements
and Approximations of Total Radioactivity
2.2.1 Sample
Collection and Analysis Gaseous Effluents at the Vogtle Electric Generating Plant are currently confined to five paths: plant vents (Unit 1 and Unit 2), the condenser air ejector, the steam packing exhauster systems (Unit 1 and Unit 2), and the Radwaste Processing Facility (RPF).Waste gas decay tanks are batch released through the Unit 1 plant vent. The containment purges are released through their respective plant vents.Containment atmosphere is also released via the containment equipment hatch during periods when the equipment hatch is open with containment purge/vent being stopped. Approval was granted by the NRC to open the equipment hatch during fuel movement; a release permit is generated when the equipment hatch is opened and the containment exhaust fan is not discharging to the plant vent.Any detected activity in the containment equipment hatch permit is included in the Ground Release Table of the effluent report.All of the paths with the exception of the RPF can be continuously monitored for gaseous radioactivity. The RPF is equipped with an integrated-type sample collection device for collecting particulates. Plant vent, containment, steam jet air ejector, steam-packing exhauster are equipped with an integrated-type sample collection device for collecting particulates and iodines. During this reporting period, there were no continuous radioactive releases through the condenser air ejector and the steam packing exhauster system vents. Batch Waste Gas Decay Tank releases are analyzed for noble gases before each release. The containment atmosphere is analyzed for noble gases prior to each release and for tritium at least on a monthly basis.Sample analysis results and release flow rates form the basis for calculating released quantities of radionuclide specific radioactivity, dose rates associated with gaseous releases, and cumulative doses for the current quarter and year.With each release period and batch release, radioactivity, dose rates, and cumulative doses are calculated. Cumulative dose results are tabulated, along with the percent of the ODCM limits for each release for the current quarter and year.Typically achieved minimum detectable concentrations for gaseous effluent sample analyses are reported in Table 2-6.Page 124 of 503
2.2.2 Total
Quantities of Radioactivity, Dose Rates, and Cumulative Doses The methods for determining release quantities of radioactivity, dose rates, and cumulative doses are as follows: 2.2.2.1 Fission and Activation Gases The released radioactivity is determined from sample analysis results collected as described above and average release flow rates over the period represented by the collected sample. Dose rates due to noble gases, radioiodines, tritium, and particulates are calculated. Calculated dose rates are compared to the dose rate limits specified in ODCM 3.1.2 for noble gases, radioiodines, tritium, and particulates. Dose rate calculation methodology is presented in the ODCM.Beta and gamma air doses due to noble gases are calculated for the location in the unrestricted area with the potential for the highest exposure due to gaseous releases. Air doses are calculated for each release period and cumulative totals are kept for each unit for the calendar quarter and year. Cumulative air doses are compared with the dose limits specified in ODCM 3.1.3. Current percent of the ODCM limits are shown on the printout for each release period. Air dose calculation methodology is presented in the ODCM.2.2.2.2 Radioiodines, Tritium and Particulate Releases The released quantities of radioiodines, tritium and particulates are determined using the weekly samples and release flow rates for the two plant vent release points.After each quarter, the particulate filters from each plant vent are combined, for strontium analysis. Strontium concentrations are input to the composite file of the computer to be used for release dose rate and individual dose calculations. Doses to a Member of the Public due to radioiodines, tritium and particulates are calculated for the controlling receptor, which is described in Table 3-7of the ODCM. Doses are calculated for each release period, and cumulative totals are kept for each unit for the current calendar quarter and year. Cumulative doses are compared to the dose limits specified in ODCM 3.1.4.Current percent of ODCM limits are shown in this report for each release period.2.2.2.3 Gross Alpha Release The gross alpha release is calculated each month by counting the particulate filters for each week for gross alpha activity. The four or five weeks' numbers are then recorded on a data sheet and the activity is summed at the end of the month. This concentration is used for release calculations. Page 125 of 503
2.2.3 Total
Error Estimation The total or maximum error associated with the effluent measurement will include the cumulative errors resulting from the total operation of sampling and measurement. Because it may be very difficult to assign error terms for each parameter affecting the final measurement, detailed statistical evaluation of error are not suggested. The objective should be to obtain an overall estimate of the error associated with measurements of radioactive materials released in liquid and gaseous effluents and solid waste.Estimated errors are based on errors in counting equipment calibration, counting statistics, vent-flow rates, vent sample flow rates, non-steady release rates, chemical yield factors, and sample losses for such items as charcoal cartridges. Total Error is calculated by the root mean square method. The root mean square value is the square root of the arithmetic mean (average) of the squares of the original values.a. Fission and activation total release was calculated from sample analysis results and release point flow rates.Sampling and statistical error in counting 10%Counting equipment calibration 10%Vent flow Rates 10%Non-steady release rates 20%TOTAL ERROR 26.5%b. 1-131 releases were calculated from each weekly sample: Statistical error in counting 10%Counting equipment calibration 10%Vent Flow Rates 10%Vent Sample Flow Rates 50%Non-Steady release rates 10%Losses from charcoal cartridges 10%TOTAL ERROR 55%c. Particulates with half-lives greater than 8 day releases were calculated from sample and analysis results and release point flow rates.Statistical error at MDC concentration 10%Counting equipment calibration 10%Vent flow rates 10%Vent sample flow rates 50%Non steady release rates 10%TOTAL ERROR 54%Page 126 of 503
2.2.3 Total
Error Estimation cont'd d. Total tritium releases were calculated from sample analysis results and release point flow rates.Water vapor in sample stream determination 10%Vent flow rates 10%Counting calibration and statistics 10%Non-steady release rates 10%TOTAL ERROR 20%e. Gross Alpha radioactivity was calculated from sample analysis results and release point flow rates.Statistical error at MDC concentration 10%Counting equipment calibration 10%Vent flow rates 10%Vent sample flow rates 50%Non Steady release rates 10%TOTAL ERROR 55%2.3 Gaseous Effluent Release Data Regulatory Guide 1.21 Rev. 1 Tables 1A, 1B, and 1C are found in this report as Tables 2-1A, 2-1B, 2-1C, 2-2A, 2-2B, 2-2C, 2-3A, 2-3B, and 2-3C. Data are presented on a quarterly basis as required by Regulatory Guide 1.21 Rev. 1.To complete table 2-1A, and 2-1 B, the total release for each of the four categories (fission and activation gases, iodines, particulates, and tritium) was divided by the number of seconds in the quarter to obtain a release rate in pLCi/second for each category. However, the percent of the ODCM limits are not applicable because VEGP has no curie limits for gaseous releases. Applicable limits are expressed in terms of dose. Noble gases are limited as specified in ODCM 3.1.2. The other three categories (tritium, radioiodines, and particulates) are limited as a group as specified in ODCM 3.1.2.Dose rates due to noble gas releases and due to radioiodines, tritium, and particulate releases were calculated as part of the pre-release and post-release permits. No limits were exceeded for this reporting period.Gross alpha radioactivity is reported in Table 2-1A, and 2-1B as curies released in each quarter.Limits for cumulative beta and gamma air doses due to noble gases are specified in ODCM 3.1.3. Cumulative air doses are presented in Table 2-4A, and 2-4B along with the percent of the ODCM limits.Page 127 of 503 Limits for cumulative doses to a Member of the Public due to radioiodines, tritium and particulates, are specified in ODCM 3.1.4. Cumulative doses to a Member of the Public are presented in Table 2-5A, and 2-5B along with percent of ODCM limits.2.4 Radiological Impact Due to Gaseous Releases Dose rates due to the release of noble gases were calculated for the site in accordance with ODCM 3.4.1.1. Dose rates due to radioiodines, tritium, and particulates in gaseous releases were calculated in accordance with ODCM 3.4.1.2.Dose rates were calculated as part of pre-release and post release permits. No limits were exceeded for this reporting period.Cumulative air doses due to noble gas releases were calculated for each unit in accordance with ODCM 3.4.2. These results are presented in Tables 2-4A and 2-4B.Cumulative doses to a Member of the Public were calculated for each unit in accordance with ODCM 3.4.3. These results are presented in Tables 2-5A and 2-58.Dose rates and doses were calculated using the methodology presented in the Vogtle Electric Generating Plant Offsite Dose Calculation Manual.2.5 Gaseous Effluents -Batch Releases Other data pertinent to batch releases of radioactive gaseous effluent from Unit 1 and Unit 2 are listed in Table 2-7A and 2-7B.2.6 Gaseous Effluents -Abnormal Releases There were no abnormal releases for 2013.Page 128 of 503 Table 2-1A VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Summation Of All Releases Unit: 1 Startina: 1-Jan- 2013 Ending: 31-Dec-2013 Tvye of Effluent Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter A. Fission And Activation Gases 1. Total Release Curies 4.79E-02 4.75E-01 1.88E+00 9.21E+00 2. Average Release rate for period uCi/sec 6.07E-03 6.03E-02 2.38E-01 1.17E+00 3. Percent of Applicable Limit % * * * *B. Radioiodines
- 1. Total Iodine-131 Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2. Average Release rate for period uCi/sec O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 3. Percent of Applicable Limit %* * * *C. Particulates
- 1. Particulates ( Half-Lives
> 8 Days) Curies 1.99E-08 2.38E-08 O.OOE+00 9.14E-07 2. Average Release rate for period uCi/sec 2.53E-09 3.02E-09 O.OOE+00 1.159E-07 3. Percent of Applicable Umit % * * * *D. Tritium 1. Total Release Curies 5.89E+00 8.54E+00 1.21E+01 1.30E+01 2. Average Release rate for period uCi/sec 7.47E-01 1.08E+00 1.53E+00 1.65E+00 3. Percent of Applicable Limit %* * * *E. Gross Alpha 1. Total Release Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2. Average Release rate for period uCi/sec O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00* Applicable limits are expressed in terms of dose. See Tables 2-4A, 2-4B, 2-5A, 2-5B of this report.If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. Page 129 of 503 Table 2-1B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Summation Of All Releases Unit: 2 Starting: 1-Jan- 2013 Ending: 31-Dec-2013 Type of Effluent Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter A. Fission And Activation Gases 1. Total Release Curies 5.13E+00 1.31E+00 4.91E-02 6.26E-02 2. Average Release rate for period uCi/sec 6.51E-01 1.66E-01 6.23E-03 7.94E-03 3. Percent of Applicable Limit % * * * *B. Radioiodines
- 1. Total Iodine-131 Curies O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 2. Average Release rate for period uCi/sec O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 3. Percent of Applicable Umit %* * * *C. Particulates
- 1. Particulates ( Half-Lives
> 8 Days) Curies O.OOE+00 6.52E-08 O.OOE+00 7.80E-08 2. Average Release rate for period uCi/sec O.OOE+00 8.27E-09 O.OOE+00 9.893E-09 3. Percent of Applicable Limit %* * * *D. Tritium 1. Total Release Curies 1.36E+01 2.84E+00 2.16E+00 8.95E-01 2. Average Release rate for period uCi/sec 1.72E+00 3.61E-01 2.74E-01 1.14E-01 3. Percent of Applicable Limit %* * * *E. Gross Alpha 1. Total Release Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2. Average Release rate for period uCi/sec O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00* Applicable limits are expressed in terms of dose. See Tables 2-4A, 2-4B, 2-5A, 2-5B of this report.If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. Page 130 of 503 Table 2-1C VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Summation Of All Releases Unit: Site Startino: 1-Jan- 2013 Ending: 31-Dec-2013 Type of Effluent Units 1ST Quarter 2ND Quarter 3RD Ouarter 4TH Quarter A. Fission And Activation Gases 1. Total Release Curies 5.18E+00 1.78E+00 1.92E+00 9.27E+00 2. Average Release rate for period uCi/sec 6.57E-01 2.26E-01 2.44E-01 1.18E+00 3. Percent of Applicable Limit % * * * *B. Radioiodines
- 1. Total Iodine-131 Curies O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 2. Average Release rate for period uCi/sec 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 3. Percent of Applicable Limit %* * * *C. Particulates
- 1. Particulates ( Half-Lives
> 8 Days) Curies 1.99E-08 8.89E-08 0.OOE+00 9.92E-07 2. Average Release rate for period uCi/sec 2.53E-09 1.13E-08 O.OOE+00 1.258E-07 3. Percent of Applicable Limit % * * * *D. Tritium 1. Total Release Curies 1.95E+01 1.14E+01 1.43E+01 1.39E+01 2. Average Release rate for period uCi/sec 2.47E+00 1.44E+00 1.81E+00 1.76E+00 3. Percent of Applicable Limit %* * * *E. Gross Alpha 1. Total Release Curies 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 2. Average Release rate for period uCi/sec O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00* Applicable limits are expressed in terms of dose. See Tables 2-4A, 2-4B, 2-5A, 2-5B of this report.Page 131 of 503 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. Page 132 of 503 Table 2-2A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Mixed Mode Level Releases Unit: 1 Starting: 1-Jan- 2013 Ending: 31-Dec-2013 Continuous Mode hiU..A- .4A 0 I hn;4©I .CTOrO+n n r")Nf f.n 1D.'0 En =r+0r ATU fnismr.r Fission Gases Xe-135 Total For Period Iodines No Nuclides Found Particulates Be-7 Sr-90 Total For Period Tritium H-3 Gross Alpha G-Alpha Total For Period Curies Curies Curies Curies Curies Curies 0.OOE+00 0.OOE+O0 0.OOE+00 1.99E-08 1.99E-08 5.78E+00 0.0OE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 2.38E-08 2.38E-08 8.46E+00 0.OOEO00 0.OOE+00 1.80E+00 1.8OE+00 0.OOE+0O 0.OOE+00 0.OOE+00 1.20E+01 5. 74E-08 5.74E-08 9.15E+00 9.15E+00 O.OOE+0O 9.14E-07 O.OOE+00 9.14E-07 1.30E+01 O.OOE+00 O.00E+00 Curies Curies Curies Page 133 of 503 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. Table 2-2A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Mixed Mode Level Releases Unit: 1 Startina: 1-Jan- 2013 Ending: 31-Dec-2013 Batch Mode MI n ,-I ,n Di lnc0 c I In;,.'I Cy r%. I)Jhlfm rm@m-nr 2aDf rl.min 'r AT- Minrma Fission Gases Ar-41 Kr-85 Xe-133 Total For Period Iodines No Nuclides Found Particulates No Nuclides Found Tritium H-3 Gross Alpha No Nuclides Found Curies Curies Curies Curies Curies 4.79E-02 O.OOE+00 O.OOE+00 4.79E-02 O.OOE+00 0.00E+00 1.14E-01 0.00E+00 Page 134 of 503 4.75E-01 0.OOE+00 0.OOE+00 4.75E-01 0.OOE+00 0.00E+00 7.97E-02 0.OOE+00 4.85E-02 2.32E-02 6.27E-04 7.24E-02 0.OOE+00 0.00E+00 5.47E-02 0.OOE+00 5.80E-02 0.OOE+00 0.OOE+00 5.80E-02 0.OOE+00 0.00E+00 2. 54E-02 0.OOE+00 Curies Curies Curies If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 2-6 for typical minimum detectable concentrations. Page 135 of 503 Table 2-2B VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Mixed Mode Level Releases Unit: 2 Startina: 1-Jan- 2013 Endina: 31-Dec-2013 Continuous Mode I KnuIM D'aIaa'ce I Inii-c 11 &-r"If o2Dn AYUW .4 2z .gua. vu. be" Mug Lý* Mug ýO ~ ..** 0 Fission Gases No Nuclides Found Iodines No Nuclides Found Particulates Sr-89 Sr-90 Total For Period Tritium H-3 Gross Alpha No Nuclides Found Curies Curies Curies Curies Curies 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 4.09E+00 0.001E+00 0.00E+00 0.OOE+00 5.24E-08 1.28E-08 6.52E-08 2.62E+00 0.OOE+00 0.00 E+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 2.04E+00 0.OOE+00 0.OOE+00 0.OOE+00 7.80E-08 0.OOE+00 7.80E-08 0.OOE+00 0.OOE÷00 Curies Curies If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 2-6 for typical minimum detectable concentrations. Page 136 of 503 Table 2-2B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Mixed Mode Level Releases Unit: 2 Startina: 1-Jan- 2013 Ending: 31-Dec-2013 Batch Mode 1ST Quarter 2ND Quarter 3RD Qua 5.67E-01 5.14E-01 3.OOE-(4.47E+00 7.93E-01 1.91E-(5.39E-02 4.77E-04 5.99E-(5.10E+00 1.31E+00 4.91E-4 O.OOE+O0 O.OOE+O0 O.OOE+i Liquid Releases Fission Gases Ar-41 Xe-133 Xe-135 Total For Period Iodines No Nuclides Found Particulates No Nuclides Found Tritium H-3 Gross Alpha No Nuclides Found Units Curies Curies Curies Curies Curies rter)2 32 D5 02 00 4TH Quarter 2.38E-02 3.83E-02 5.14E-04 6.26E-02 O.OOE+O0 Curies Curies 0.OOE+00 9.43E+00 O.OOE+00 O.OOE+00 2.18E-01 O.OOE+O0 O.00E+00 1.26E-01 O.OOE+OO O.OOE+OO 8.95E-01 O.OOE+00 Curies Page 137 of 503 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. Page 138 of 503 Table 2-2C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Mixed Mode Level Releases Unit: Site Startina: 1-Jan- 2013 Ending: 31-Dec-2013 Continuous Mode 1ST Quarter 2ND Quarter 3RD Qua Nuclide Releases Fission Gases Xe-135 Total For Period Iodines No Nuclides Found Particulates Be-7 Sr-89 Sr-90 Total For Period Tritium H-3 Gross Alpha G-Alpha Total For Period Units irter Curies Curies Curies Curies Curies Curies Curies O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+O0 1.99E-08 1.99E-08 9.86E+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 5.24E-08 3. 66E-08 8.89E-08 1.11E+01 O.OOE+00 O.OOE+00 1.80E+00 1.80E+00 0.OOE+00 0.OOE+0O 0.OOE+00 0.OOE+00 0.OOE+00 1.41E+01 5.74E-08 5.74E-08 4TH Quarter 9.15E+00 9.15E+00 0.OOE+00 9.14E-07 7.80E-08 0.OOE+00 9.92E-07 1.30E+01 O.OOE+00 0.O0E+00 Curies Curies Curies If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. Page 139 of 503 Table 2-2C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Mixed Mode Level Releases Unit: Site Starting: 1-Jan- 2013 Endina: 31-Dec-2013 Batch Mode Iu 1,,- .1 Dn_1 " I ;0-12 lu r% .4-*'II m m ATU m EU LI =LI =00I =0 ~ LIN L3 J.L I LIMUE3 LV.1 I U ju l~I ~ ~ ~ M I mdu E V§ U e U U ý ~Fission Gases Ar-41 Kr-85 Xe-133 Xe-135 Total For Period lodines No Nuclides Found Particulates No Nuclides Found Tritium H-3 Gross Alpha No Nuclides Found Curies Curies Curies Curies Curies Curies 6.15SE-01 0.OOE+0O 4.47E+00 5.39E-02 5.14E+00 0.OOE+00 0.OOE+00 9.54E+00 0.OOE+00 9.89E-01 0.OOE+00 7.93E-01 4. 77E-04 1.78E+00 0.OOE+00 0.OOE+00 2.98E-0 1 0.OOE+O0 7.86E-02 2.32E-02 1.97E-02 5.99E-05 1.22E-01 O.OOE+00 O.OOE+00 1.81E-01 O.OOE+00 8.18E-02 O.OOE+00 3.83E-02 5.14E-04 1.21E-01 O.OOE+00 O.OOE+00 9.20E-01 O.OOE+0O Curies Curies Curies Page 140 of 503 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels.See Table 2-6 for typical minimum detectable concentrations. Page 141 of 503 Table 2-3A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Ground Level Releases Unit: 1 Starting: 1-Jan- 2013 Ending: 31-Dec-2013 Continuous Mode 1ST Ouarter 2ND Ouarter 3RD Oua O.OOE+00 O.OOE+00 O.OOE+(Nuclide Releases Fission Gases No Nuclides Found Iodines No Nuclides Found Particulates No Nuclides Found Tritium No Nuclides Found Units Curies rter O0 4TH Ouarter O.OOE+00 Curies Curies 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 Curies Gross Alpha No Nuclides Found Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels.Page 142 of 503 See Table 2-6 for typical minimum detectable concentrations. Table 2-3A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Ground Level Releases Unit: 1 Starting: 1-Jan- 2013 Ending: 31-Dec-2013 Batch Mode Nirlida Rp~lpacac== Iinitc 1 7)Nfl fl..arurlrfIl:uIrfprr 4TM Nfal~urI~Units JQT n"n or 2ND nuarter 3RD Ong or 4TH n"garter Fission Gases No Nuclides Found Iodines No Nuclides Found Particulates No Nuclides Found Tritium No Nuclides Found Curies O.OOE+O0 O.OOE+00 O.OOE+O0 O.OOE+O0 Curies O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+00 Curies O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 Curies O.OOE+0o O.OOE+0O O.OOE+00 O.OOE+O0 Gross Alpha No Nuclides Found Curies O.OOE+0O Page 143 of 503 O.OOE+00 O.OOE+00 O.OOE+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 2-6 for typical minimum detectable concentrations. Page 144 of 503 Table 2-3B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Ground Level Releases Unit: 2 Startina: 1-Jan- 2013 Endina: 31-Dec-2013 Continuous Mode N.rlide Ilnitc 1 flh,2rter 7 Nf Amumrt~~rAmlra~r'r 4TH fliirt~r Nuclide Releases Units IST nun -or 2ND inuarter 3RD nua er 4TH nuarter Fission Gases No Nuclides Found lodines No Nuclides Found Particulates No Nuclides Found Tritium No Nuclides Found Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Gross Alpha No Nuclides Found Curies O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 2-6 for typical minimum detectable concentrations. Page 145 of 503 Table 2-3B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Ground Level Releases Unit: 2 Startina: 1-Jan- 2013 Endina: 31-Dec-2013 Batch Mode Ni ir"lign cajc Ilnifc 1 lNfl flnimrh~rfl.iart~r 4TH Anartpr Units IST nua er 2ND nuarter 3RD Ouarter Fission Gases Ar-41 Xe-133 Xe-135 Total For Period lodines No Nuclides Found Particulates No Nuclides Found Tritium H-3 Gross Alpha No Nuclides Found Curies Curies Curies Curies 3.67E-03 3.01E-02 3.72E-04 3.42E-02 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Curies 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Curies Curies O.OOE+00 7.42E-02 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 Curies 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels. See Page 146 of 503 Table 2-6 for typical minimum detectable concentrations. Page 147 of 503 Table 2-3C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Ground Level Releases Unit: Site Starting: 1-Jan- 2013 Ending: 31-Dec-2013 Continuous Mode Nuclide Releases Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter Fission Gases No Nuclides Found Curies O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+O0 lodines No Nuclides Found Curies O.OOE+O0 O.OOE+O0 O.OOE+0O O.OOE+O0 Particulates No Nuclides Found Curies O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+O0 Tritium No Nuclides Found Curies O.OOE+O0 O.OOE+00 O.OOE+O0 O.OOE+00 Gross Alpha No Nuclides Found Curies O.OOE+00 O.OOE+O0 O.OOE+0O O.OOE+O0 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 2-6 for typical minimum detectable concentrations. Page 148 of 503 Table 2-3C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Ground Level Releases Unit:Site Startino: 1-Jan- 2013 Endina: 31-Dec-2013 Batch Mode Nirlida gplpacpc ilnitc 1 ~ Am ,rI~rlrO.artor~Rfl AmiarI~r 4TH l.arn~rh Units 1ST nua er 2ND nua er 3RD nuar+er 4TH nuarter Fission Gases Ar-41 Xe-133 Xe-135 Total For Period Iodines No Nuclides Found Particulates No Nuclides Found Tritium H-3 Gross Alpha No Nuclides Found Curies Curies Curies Curies 3.67E-03 3.01E-02 3.72E-04 3.42E-02 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Curies Curies 0.OOE+00 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 Curies 7.42E-02 0.OOE+00 0.OOE+00 0.OOE+00 Curies 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 2-6 for typical minimum detectable concentrations. Page 149 of 503 Table 2-4A VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Ground Level Releases Unit: 1 Startina: 1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Type of Radiation ODCM Lint Units Gamma Air 5.OOE+00 mRad Beta Air 1.OOE+01 mRad 1ST Qtr 6.52E-06 2.30E-06%/o ODCM 1.30E-04 2.30E-05 2ND Qtr 6.47E-05 2.28E-05%/a ODCM 1.29E-03 2.28E-04 3RD Qtr 5.73E-05 6.80E-05 0/b ODCM 1. 15E-03 6.80E-04 4TH Qtr 2.65E-04 3.33E-04%/o ODCM 5.31E-03 3.33E-03 Cumulative Doses Per Year Type of Radiation ODCM Lint Gamma Air 1.00E+01 Beta Air 2.OOE+01 Units mRad mRad Year to End Date 3.94E-04 4.26E-04%/c ODCM 3.94E-03 2.13E-03 Receptor Site Boundary / Child Site Boundary / Child Limit Air Dose Gamma Annual 1.21 Air Dose Beta Annual 1.21 Page 150 of 503 Table 2-46 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Ground Level Releases Unit: 2 Starting: 1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Type of Radiation ODCM Lint Units Gamma Air 5.OOE+00 mRad Beta Air 1.00E+01 mRad 1ST Qtr 1.06E-04 1.02E-04%/o ODCM 2.11E-03 1.02E-03 2ND Qtr 7.41E-05 3.69E-05%/o ODCM 1.48E-03 3.69E-04 3RD Qtr 4.19E-06 1.74E-06 0/0 ODCM 8.38E-05 1.74E-05 4TH Qtr 3.45E-06 1.75E-06%/o ODCM 6.90E-05 1.75E-05 Cumulative Doses Per Year Type of Radiation ODCM Lrnt Gamma Air 1.00E+01 Beta Air 2.OOE+01 Units mRad mRad Year to End Date 1.87E-04 1.42E-04%/o ODCM 1.87E-03 7. 1OE-04 Receptor Site Boundary / Child Site Boundary / Child Limit Air Dose Gamma Annual 1.21 Air Dose Beta Annual 1.21 Page 151 of 503 Table 2-4C VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Ground Level Releases Unit: Site Starting: 1-lan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Type of Radiation ODCM Lmt Units 1ST Qtr %/a ODCM 2ND Qtr %/a ODCM 3RD Qtr %/o ODCM 4TH Qtr %/a ODCM Gamma Air Beta Air 5.OOE+00 mRad 1.12E-04 2.24E-03 1.39E-04 2.78E-03 6.15E-05 1.23E-03 2.69E-04 5.38E-03 1.00E+01 mRad 1.04E-04 1.04E-03 5.97E-05 5.97E-04 6.97E-05 6.97E-04 3.34E-04 3.34E-03 Cumulative Doses Per Year Type of Radiation ODCM Lmt Units Year to End Date% ODCM Receptor Limit Gamma Air Beta Air 1.OOE+01 mRad 2.OOE+01 mRad 5.81E-04 5.68E-04 5.81E-03 Site Boundary / Child 2.84E-03 Site Boundary / Child Air Dose Gamma Annual 1.21 Air Dose Beta Annual 1.21 Page 152 of 503 Table 2-5A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses To a Member of the Public Due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: 1 Startina: 1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Uver Lung Thyroid Total Body ODCM Lint 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 Units mRem mRem mRem mRem mRem mRem mRem IST Qtr 7.91E-07 1.27E-04 1.27E-04 1.27E-04 1.27E-04 1.27E-04 1.28E-04 0/0 ODCM 1.05E-05 1.70E-03 1.70E-03 1.70E-03 1. 70E-03 1.70E-03 1.70E-03 2ND Qtr 9.43E-07 1.85E-04 1.85E-04 1.85E-04 1.85E-04 1.85E-04 1.85E-04 0/o ODCM 1.26E-05 2.46E-03 2.46E-03 2.46E-03 2.46E-03 2.46E-03 2.46E-03 3 RD Qtr 0.00E+00 2.61E-04 2.61E-04 2.61E-04 2.61E-04 2.61E-04 2.61E-04 0/o ODCM 0.OOE+00 3.49E-03 3.49E-03 3.49E-03 3.49E-03 3.49E-03 3.49E-03 4TH Qtr 0.OOE+00 2.81E-04 2.81E-04 2.81E-04 2.81E-04 2.81E-04 2.81E-04%/o ODCM 0.OOE+00 3.75E-03 3.75E-03 3.75E-03 3.75E-03 3.75E-03 3.75E-03 Cumulative Doses per Year Organ Bone GI-Lli Kidney Liver Lung Thyroid Total Body ODCM Lmt 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 Units mRem mRem mRem mRem mRem mRem mRem Year to Ending Date/o ODCM Receptor Limit 1.734E-06 8.545E-04 8.545E-04 8.545E-04 8.545E-04 8.545E-04 8.549E-04 1. 156E-5 5.697E-03 5.697E-03 5.697E-03 5.697E-03 5.697E-03 5.700E-03 Maximum Individual Maximum Individua Maximum Individua Maximum Individua Maximum Individua Maximum Individua Maximum Individual / Child/ Child/ Child/ Child/ Child/ Child/ Child Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual 1.21 1.21 1.21 1.21 1.21 1.21 1.21 Page 153 of 503 Table 2-5B VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses To a Member of the Public Due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: 2 Startina: 1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Uver Lung Thyroid Total Body ODCM Lmt 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 Units mRem mRem mRem mRem mRem mRem mRem 1ST Qtr O.OOE+O0 3.OOE-04 3.OOE-04 3.OOE-04 3.OOE-04 3.OOE-04 3.OOE-04%/o ODCM O.OOE+O0 4.OOE-03 4.OOE-03 4.OOE-03 4.OOE-03 4.OOE-03 4.OOE-03 2ND Qtr 5.69E-07 6.15E-05 6.15E-05 6.15E-05 6.15E-05 6.15E-05 6.16E-05 0/o ODCM 7.59E-06 8.20E-04 8.20E-04 8.20E-04 8.20E-04 8.20E-04 8.21E-04 3RD Qtr O.OOE+00 4.67E-05 4.67E-05 4.67E-05 4.67E-05 4.67E-05 4.67E-05 0/o ODCM 0.OOE+00 6.23E-04 6.23E-04 6.23E-04 6.23E-04 6.23E-04 6.23E-04 4TH Qtr 9.17E-08 1.94E-05 1.93E-05 1.93E-05 1.93E-05 1.93E-05 1.94E-05 0/b ODCM 1.22E-06 2.58E-04 2.58E-04 2.58E-04 2.58E-04 2.58E-04 2.58E-04 Cumulative Doses per Year Organ Bone GI-Lli Kidney Uver Lung Thyroid Total Body ODCM Lmt 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 Units mRem mRem mRem mRem mRem mRem mRem Year to Ending Date 0/a ODCM Receptor Limit 6.606E-07 4.276E-04 4.276E-04 4.276E-04 4.276E-04 4.276E-04 4.277E-04 4.404E-6 2.850E-03 2.850E-03 2.850E-03 2.850E-03 2.850E-03 2.851E-03 Maximum Individual Maximum Individua Maximum Individua Maximum Individua Maximum Individua Maximum Individua Maximum Individual / Child/ Child/ Child/ Child/ Child/ Child/ Child Iodine/Part Dose Annual 1.21 Iodine/Part Dose Annual 1.21 Iodine/Part Dose Annual 1.21 Iodine/Part Dose Annual 1.21 Iodine/Part Dose Annual 1.21 Iodine/Part Dose Annual 1.21 Iodine/Part Dose Annual 1.21 Page 154 of 503 Table 2-5C VogUe Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses To a Member of the Public Due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: Site Starting: 1-Jan- 2013 Endina: 31-Dec-2013 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Uver Lung Thyroid Total Body ODCM Lint 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 7.50E+00 Units mRem mRem mRem mRem mRem mRem mRem 1ST Qtr 7.91E-07 4.27E-04 4.27E-04 4.27E-04 4.27E-04 4.27E-04 4.28E-04%/o ODCM 1.05E-05 5.70E-03 5.70E-03 5.70E-03 5.70E-03 5.70E-03 5.70E-03 2ND Qtr 1.51E-06 2.46E-04 2.46E-04 2.46E-04 2.46E-04 2.46E-04 2.46E-04% ODCM 2.02E-05 3.28E-03 3.28E-03 3.28E-03 3.28E-03 3.28E-03 3.28E-03 3RD Qtr O.OOE+00 3.08E-04 3.08E-04 3.08E-04 3.08E-04 3.08E-04 3.08E-04%/ ODCM O.OOE+OO 4.11E-03 4.11E-03 4.11E-03 4.11E-03 4.11E-03 4.11E-03 4TH Qtr 9.17E-08 3.OOE-04 3.OOE-04 3.OOE-04 3.OOE-04 3.OOE-04 3.OOE-04% ODCM 1.22E-06 4.01E-03 4.01E-03 4.01E-03 4.01E-03 4.01E-03 4.01E-03 Cumulative Doses per Year Organ Bone GI-Lli Kidney Uver Lung Thyroid Total Body ODCM Lmt 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 Units mRem mRem mRem mRem mRem mRem mRem Year to Ending Date% ODCM Receptor 2.395E-06 1.282E-03 1.282E-03 1.282E-03 1.282E-03 1.282E-03 1.283E-03 1.597E-05 8.547E-03 8.547E-03 8.547E-03 8.547E-03 8.547E-03 8.551E-03 Maximum Individual Maximum Individual Maximum Individual Maximum Individual Maximum Individual Maximum Individual Maximum Individual / Child I Child/ Child I Child/ Child/ Child/ Child Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Iodine/Part Dose Annual Limit 1.21 1.21 1.21 1.21 1.21 1.21 1.21 Page 155 of 503 Page 156 of 503 Table 2-6 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 MINIMUM DETECTABLE CONCENTRATIONS GASEOUS SAMPLE ANALYSES Starting: 1-Jan-2013 Ending: 31-Dec-2013 RADIONUCLIDE MDC UNITS Kr-87 1.82E-08 iiCi/ml Kr-88 2.53E-08 p.Ci/ml Xe-133 2.05E-08 pCi/ml Xe-133m 8.63E-08 p.Ci/ml Xe-135 7.12E-08 P.Ci/ml Xe-138 1.05E-07 tCi/ml 1-131 7.93E-15* pCi/ml Mn-54 3.94E-14* !pCi/ml Fe-59 2.45E-14* ilCi/ml Co-58 1.39E-14* ptCi/ml Co-60 1.75E-14* ipCi/ml Zn-65 2.82E-14* ptCi/ml Mo-99 9.57E-14* pCi/ml Cs-134 1.12E-14* pCi/ml Cs-137 8.71E-15* ptCi/ml Ce-141 8.62E-15* ptCi/ml Ce-144 2.77E-14* pCi/ml Sr-89 1.OOE-13 pCi/ml Sr-90 1.OOE-13 pLCi/ml H-3 9.OOE-08 pCi/ml Gross Alpha 1.00E-13 p.Ci/ml* Based on an estimated sample volume of 5.7E+08 mis for particulate filters and charcoal cartridges. Page 157 of 503 Table 2-7A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Batch Release Summary Unit: 1 Startina: 1-Jan- 2013 Endina: 31-Dec-2013 f-, &-^.- DM-ý-e Ilni4.1. Number of batch releases 2. Total time period for batch releases 3. Maximum time period for a batch release 4. Average time period for a batch release 5. Minimum time period for a batch release ( Minutes)(Minutes)(Minutes)(Minutes)1ST Ouarter 28 1.55E+03 1.OOE+02 5.52E+01 7.OOE+00 2ND Quarter 3RD Quarter 4TH Ouarter 42 32 32 3.38E+03 3.37E+03 2.05E+03 4.80E+02 1.03E+03 1.50E+02 8.06E+01 1.05E+02 6.41E+01 3.OOE+O0 2.10E+01 2.60E+01 Year Totals Year Totals 134 1.04E+04 1.03E+03 7.73E+01 3.OOE+O0 Page 158 of 503 Table 2-7B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Batch Release Summary Unit: 2 Startina: 1-Jan- 2013 Endina: 31-Dec-2013 r .eaue a ea I Inilc ICT ga'rN, t r 2Nfl flf.2r4~nr 2Dfl flm.~rt~r ~TI.I fluI2rta~r ,3mn n"nr+ar 'ADD n"n or AT&i nu:%r+ar b!1. Number of batch releases 2. Total time period for batch releases 3. Maximum time period for a batch release 4. Average time period for a batch release 5. Minimum time period for a batch release (Minutes)(Minutes)(Minutes)(Minutes)39 2.70E+04 8.OOE+03 6.93E+02 6.OOE+O0 12 8.42E+03 7.99E+03 7.02E+02 1.00E+01 11 7.21E+02 2.93E+02 6.55E+01 2.30E+01 12 5.98E+02 1.39E+02 4.98E+01 2.40E+01 Year Totals 74 3.67E+04 8.OOE+03 4.97E+02 6.OOE+O0 Page 159 of 503 Table 2-7C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Batch Release Summary Unit: Site Startina: 1-lan- 2013 Ending: 31-Dec-2013 gaseous Releases Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter Year Totals 1. Number of batch releases 67 54 43 44 208 2. Total time period for batch releases (Minutes) 2.86E+04 1.18E+04 4.09E+03 2.65E+03 4.71E+04 3. Maximum time period for a batch release (Minutes) 8.OOE+03 7.99E+03 1.03E+03 1.50E+02 8.OOE+03 4. Average time period for a batch release (Minutes) 4.26E+02 2.19E+02 9.52E+01 6.02E+01 2.26E+02 5. Minimum time period for a batch release (Minutes) 6.OOE+0O 3.OOE+0O 2.10E+01 2.40E+01 3.OOE+0O Page 160 of 503 Table 2-8A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Abnormal Release Summary Unit: 1 Startina: 1-Jan- 2013 Ending: 31-Dec-2013 Gaseous Releases Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter Year Totals 1. Number of Releases 0 0 0 0 0 2. Total Time For All Releases (Minutes) O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 3. Maximum Time For A Release (Minutes) O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 4. Average Time For A Release (Minutes) O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 5. Minimum Time For A Release (Minutes) O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 6. Total activity for all releases (Curies ) O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Page 161 of 503 Table 2-8B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Abnormal Release Summary Unit: 2 Startina: 1-Jan- 2013 Endina: 31-Dec-2013 Gaseous Releases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Year Totals 1. Number of Releases 0 0 0 0 0 2. Total Time For All Releases (Minutes) O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 3. Maximum Time For A Release (Minutes) O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 4. Average Time For A Release (Minutes) O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 5. Minimum Time For A Release (Minutes) O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 6. Total activity for all releases (Curies ) O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Page 162 of 503 Table 2-8C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Gaseous Effluents -Abnormal Release Summary Unit: Site Starting: 1-Jan- 2013 Endina: 31-Dec-2013 Gaseous Releases Units 1ST Ouarter 2ND Ouarter 3RD Ouarter 4TH Ouarter Year Totals 1. Number of Releases 0 0 0 0 0 2. Total Time For All Releases (Minutes) 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 3. Maximum Time For A Release (Minutes) 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 4. Average Time For A Release (Minutes) 0.00E+00 0.OOE+00 0.OOE+00 0.00E+00 0.00E+00 5. Minimum Time For A Release (Minutes) 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 6. Total activity for all releases (Curies ) 0.00E+00 0.OOE+00 O.OOE+00 0.OOE+00 0.00E+00 Page 163 of 503
3.0 Solid
Waste 3.1 Regulatory Requirements The ODCM requirements presented in this section are stated in part for Unit 1 and Unit 2.3.1.1 Solid Radioactive Waste System 10.2.1 Process Control Program (PCP)Radioactive wastes shall be solidified or dewatered in accordance with the PCP to meet shipping and transportation requirements during transit and disposal site requirements when received at the disposal site.3.1.2 Reporting Requirements 12.1 PCP states in part: The Radioactive Effluent Release Report, submitted in accordance with Technical Specification 5.6.3, shall include a summary of the quantities of solid radwaste released from the units, as outlined in Regulatory Guide 1.21 Rev 2.3.2 Solid Waste Data Regulatory Guide 1.21 Rev 2, Table 3 is found in this report as Table 3-1. GEL Laboratories performs hard-to-detect analysis for solid waste. Final calculations for nuclides include sample analysis performed on resin from High Integrity Containers. For Gaseous and Liquid composites, the Georgia Power Environmental Laboratory performs hard-to-detect analysis.Page 164 of 503 Table 3-1 Vogtie Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units 1 and 2 Page 1 of 9 JANUARY 1, 2013 THROUGH JUNE 30, 2013 Page 165 of 503 Regulatory Guide 1.21, Effluent and Waste Disposal Semi-Annual Report ot Solid Waste and Irradiated Fuel Shipments ¢/aT,, PERIOD COVERED: FROM: 1/1/2.013 TO: 6="O/2013 FOR UNIT I & 2 A. SOIUD WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not iradbaled tuel)I.. Type of waste UNIT 6 month Est, Total......_peiod ERROR %Dry oornpTes5fe waste, contaninated equip. fro 1ý83E2 25 etc. ,V U Ci=-0s A?) Cl 5.27E-1 25 Steam Generator Blow Down Resin (Seconcdary Side Resin) _e 6,43EI 25 2. Es-timat~e of maiom nue~ft compxosion (by peof waste)ISOTOPE PERCENT CURIES[ycaipressible waste, contaminated equip. e~c WNA N/A Co,58 46.933 2.47e-1 CO-60 16.526 8.7Ne-2 Cr-51 111,053 5.82e-2 Fe--55 8.,50 4.48e-2 Nb-95 6.288 2.78e-2 NI-63 3.843 2.02e-2 Mn-54 2.963 1.55e-2 Zr-95 2.586 1.38e-2 Fe-59 0,538 2.82a.3 Zn.65 0.367 1.93e,3 Sb-1 25 0.381 1.900-3 Cs-137 0.260 1.37e-3 Sn-1 13, H-3, U0-57, Cs-134, C-14, St-90 I.% 4,1 le-3 Stoam Generator Slow Down Resin (Secondaiy Side Resin) .......Co-58 39.107 9.1 te-3 CO-60 23,996 5,560-311.553 2.6N-3 M-__..63 7-219 1.63e-3 Ct-5I 6.460 1,.27e..3 Mn-64 3.346 7.790.4 Nb-95 3.106 7.23e-42.076 4.83e4 H-3 1.699 3.96-4 Sb- 125 0.544 127e-4 Cs- 137 ,0r.4 1,,14ea4 Zn-65 0.394 9.17a-5 Fe,59 0.363 6.46e-.Co-57 0.226 5.21e-5 0S- ,1 ,- 5.230e-Cs-1134. C-14, Sr-90, Co-1 44, Nb-94, Sol.124 >%6-949-2 Table 3-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units 1 and 2 JANUARY 1, 2013 THROUGH JUNE 30, 2013 Page 166 of 503 Page 2 of 9 NRC Regulatory Guide 1.21 Reports Page 1 ReportDate: 30812014 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream Ouring Period From 01101)2013 to 06&3V2013 Percent Cutaff 0 Waste Siream: Resins, Fifters, and Evap Bottomns Waste Volume Curies % Error Class Ft^3 MA3 Shipped (Ci)A 0=00E+00 000E+00 0,00E+00 +t/ 25%B 000E+0O 0.OOE÷00 0.00E+00 ÷1/ 25%C 0.00E+00 0.00E+00 0.OQE+00 +/1 25%All 0.00E+00 O.OOE+00 0.00E+00 +1- 25%Waste Stream SS DAW Dry Active Waste Dry Active Waste*waste Vof ure Curies %Error Class3Ft' 3 Shipped i CI)C 0.0OE+00 0.OOE+00 0,OOE.O0 +1-25%All ;.47E+03 1.83E+02 5.27E-01 +1 *25%Waste Stream Irradiated Components w~ipVolume Curies ý4 Error Class FtA3 M-%3 Shipped iCl)A O0O0E+00 0.OOE+00 0.00E+0O +/-25%B 0.C0E+00O .OOE+O0 0.OOE+0O +1-25%C 0,00E+00 000OE+00 i 0.0OE+00 +1-25%All I0.OOE+00 0,O0E+00 0.OOE+00 +/-26%Table 3-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units I and 2 Page 167 of 503 Page 3 of 9 JANUARY 1, 2013 THROUGH JUNE 30, 2013 NRC Regulatory Guide 1.21 Reports P;UA 2 Report Date" 3W/12014 Solid Waste Shipped Qftsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Perfiod From 0110112013 to 06130/2013 Percent Cutoff 0 Waste Stream Other Waste SGDU C,.,51N (1olt) SGBO Resin (Clips)Waste Volume Curies % Error class FtA3 M,3 Shipped (Ci)A 2,27E+a3 6,43E+O1 2,33E-02 41-25%S 0,00E+00 0.00E+00 0.00E+00 +1-25%C 0,OOE+00 0,00E+O0 0.00E+00 +1-25%All 2,27E+03 6-43E+01 2.33E-02 +1-25%Waste Stream : Sum or A41 4 Categorfes SGBD RESIN (Bolt) SS DAW Dry Active Waste* SGBD Resin (Clips)Waste Volume Curies % Error Class j FtA3 MA3 Shipped (CI)A [8774E+03 2.47E+02 5.50E-01 +/-25%B 0.00E+00 0.00E+-00 0,OOE+00 +/-25%C .OOE+00 0.OOE+00 0.00E+00 +1-25%AJI 8j 74 E+03 2ý47E.02 5,50E.01 +1.25%-Combined Waste Type Shipment, Major Volume Waste Type Shown Table 3-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL REPORT -2013 Page 168 of 503 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units I and 2 JANUARY 1, 2013 THROUGH JUNE 30, 2013 NRC Regulatory Guide 1.21 Reports Page 4 of 9 Page 1 Report Date: 3/6I2014..... ... ..... ... ... ..... ..... .... ..............,... ... .... .. ..... ......Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/0112013 to 06/3012013 "7L .".7 "" ' .... ..... .... " "........ ". ..... .... .." ........ .... ... ......... ..... ... ..: .. ; .."'.....:., ', Number of Shipments Mode of Transportation Destinatlei' 5 Hittman Transport ENERGY SOLUTIONS 4 Hiftman Transport GTSD GALLAHER TABLE 3-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT -2013 Page 169 of 503 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units 1 and 2 JULY 1, 2013 THROUGH DECEMBER 31, 2013 Page 5 of 9 Regulatory Guide 1.21: Effluent and Waste Disposal Semi-Annual Report of Solid Waste and Irradiated Fuel Shipments PERIOD COVERED: FROM: 72013 ... TO: 12/31L21 3 FOR UNIT: !A.2 _A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)Type of waste UNIT 6 month Esi, Total........... period ERROR %Rosins and Filters (NRC Waste Class A) m3 102 EI 25 Ci 2.,3Ei 25 Dry compressible waste. corntaminated equip. T -5.01 El 25 etc., (NRC Waste Class A) CI 2.64E-2 25 Steam Generator Blow Down Rosin (Secondary Side tm 3.70E1 25 (NRC Waste Class A Ci 5.,58E,3 25 2. Eslimate of major nuclide composition (by tyr* of waste)ISOTOPE PERCENT CURIES Resins and Filters (NRC Waste Class A)Ni-63 42.644 1.02E1 Com60 28,314 5.75 Fe-55 15.718 3.75 Cs-137 5.080 1,21 Co-68 3.604 859E.1 SbI25 1.335 3.1BE-1 , Cs-134 ................ 0.849 2.02E-1 C-14 , 0.815 1.94E-1 Mn-54 0.749 1-78E-l Nb-95 0.199 4.73E-2 Ni-59 0,194 4.62E-2 Zr-95 0.130 3.11 E-2 7n-65 0,106 2.53E-2 H-3,Co-57,Sr-9.0,Cr-51 ,Tc-99,Fe-.9Sn.1-13,Nb-94.Ce-144,Pu-241 >0.1% 6.25E-2 Dry compressible waste, contaminated equip. etc NA .A (NRC Waste Class A)_________ ________Co058 46.319 1.22E-2 Co-60 1-199 4.80E-3 Fe-5, 9,334 2,46E-3 Cr-5i 9-137 2.41E-3 Nb-95 4.647 1.23E-3 NI-63 4.249 2.02E-2 Mn,54 3.183 1.12E-3_____________________________ 2.522 6.65E-4 Fe-59 0.495 1.31E-4 Sb'125 0.396 1.04E-40.3w 1.04E-4 Cs-137 0.287 7.57E-5 Sn-I 13, K-.3, Co-57, Cs-134, C-14, S-90 .. I1% 2.12E-4 TABLE 3-1 Page 170 of 503 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units I and 2 Page 6 of9 JULY 1, 2013 THROUGH DECEMBER 31, 2013 Steam Oenerator Blow Down Resin (Secondary Side Resin)ANRC Waste Class A) ........Co-58 36.717 2,05E-3 Co-60 28.398 1,5aE.3 Fe-55 14.106 7.78E-4 Ni-63 6.85. " 3-E-4 Mn-54 4.234 2.36E-4 Cr-51 2,871 160,E-,4 Nb-95 1.990 iE11-4 Zr-95 T.871 1.04E-4 Sb-I25 0.599 3.34E-5 Zn-66 0,499 2,78E-5 Cs-137 0.461 2.57E-5 H--3 0.359 2.OOE-50.275 1.53E-5 Fe-59 0274 1 ,53E-5 Sn-i 13 0.244 1.38E-6 Cs-134, C-14,.St-.90 .A. .1% 1.3GE-5 3. Solid Waste, Visposiflon NuMkhe o ý pmnt 3 Re,-*n tidqqouTr!ý ordatiw Transler Truck with Cask DotnationSolutions Barmvell Processing Facility 16043 Dunbarton Blvd Barnwall, SC 2 Filler 1 DAW Transfer Ttuck with Cask Exclusive use transfaT truck~Energy Solutions 1560 Bear Creek Rd Oak Ridge, TN Energy Soluions 1560 Bear Creek Rd?Oak Ridge, TN Energy Soluilons ,628 Gallahei Rd EKingston. TN 2 Otier (SeM Resin)transfer Truck 13. IRRADIATED FUEL SHIPMENTS (Disp~osition) NUmbot of ShiuMents Mgde gf TrMnsportation None NIA ,Nglirjation NIA TABLE 3-1 Page 6 of 503 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units 1 and 2 Page 172 of9 JULY 1, 2013 THROUGH DECEMBER 31, 2013 Page 172 of 5003 NRC Regulatory Guide 1.21 Reports Noge Report Date: 3*12014 Solid Waste Shipped Offsite for Disposal and Estimates of Ma~or Nuclides by Waste Class and Stream During Period From 0710112013 to 1213012013 Percent Cutoff: 0 Waste Stream, Resins, Filters, and Evap Bottoms HIC 11743-01 SFP FILTERS 07-08 RPF Resin TUFS Membranes 3698-13 Waste Volume Cures % Error Class FtA3 M^3 Shipped (Cl)A 316iE+02 1.02E+01 2.38E*01 +f- 25%B 0.00E+00 0,00E+O0 0.OOE+00 +1- 25%C 0O.0E+00 0,00E+00 0.OOE+00 +1- 25%All 3.61E+02 1.02E+01 2.38E+01 +/-25%Waste Stream : Dry Active Waste Dry Actve Wastek Waste Volume CuriesI %Error Cl~ass FtA3 M113 Shipped j (CIq A 1,77E+03 6-01 E+01 2,64&~02 -5 a 0.0QE+00 O.0OE+00 0.0OE+00 f 1-25%C 0.O0Q4-00 0O0OE+00 0.00E+00 j +1-25%All 1.77E+0~3 5.01 E+01 2.641202 +1-25%Waste Stream , Irradiated Components Waste Volume Curies % Error Class FtA3 MA3 Shipped (Ci)A 0=00E+00 0.00E.00 0.00E+00 +/-25%B 0-OOE+00 O.OOE+00 0.00E+00 +1-25%C 0.002E+00 0.OOE+00 0.00E+O0 +-25%All 0.0oE+00 o 0,0E1+O0 .OOE+00 +/-25%TABLE 3-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Units 1 and 2 Page 8 of 9 Page 173 of 503 JULY 1, 2013 THROUGH DECEMBER 31, 2013 NRC Regulatory Guide 1.21 Reports TPege 2Date: W362914 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Peiod From 07t01/2013 to 12130/2013 Percent Cutoff' 0 Waste Stream Other Waste SGBD RESIN (Bolt) SGBD Resin (Clips)Waste Volume Curies % Error Class FtA3 MA3 Shipped ICi)A 1,31E+03 3,70E+01 5.58E-03 +1-25%B O.00E+00 O.00E+00 O.OE+0-25% C Q,00E+O0 0.OOE+00 O,OOE+00 +/-25%All 1,31E+03 3.70E+01 6.68E-O3 +/-25%Waste Stream : Sum of All 4 Categories SGBD RESIN (Bolt) HIC 11743-OI RPF Resin TUFS Membranes SFP FILTERS 07-08 Dry Active Waste*3698-13 SGBD Resin (Clips)waste Volume Curies % Error Class Ft&3 MA3 Shipped P)i A 144E+03 9.73E+01 2,39E+01 +1-25%B O-0OE+00 04012+00 0.00E+00 +/-25%C 0.00E+O0 O.00E+00 OOOE.+00 +1-25"A Ali 3,44E+.03 9.73E+01 2.39E+0O1 +1-25%-Combined Waste Type Shipment, Major Volume Waste ae Shown TABLE 3-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT -2013 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Page 174 of 503 Urits I ard 2 AllY 1,2013 THROIiH IJECEI'IJER 31,2013 NRC Regulatory Guide 1.21 Reports Page9 d 9 Page I Report Date: :lill 01 Solid Waste Shipped Offsite for 15sposaland Estimatesof Major Nuclides by Waste Class and Stream Durtng Period From 0710112013 to 1213012013 Number of Shlpmetats ,_of Transportation Destination 3 Hittman Transport O'tQC<Koong Facity.3 HlttmanTransport L T1 10 N" 2 HillmanTransport IGT IGALLAHER 4.0 Doses to Members ofthe Public inside the Site Boundary Page 175 olf503
4.1 Regulatory
Requirements ODCM 7.2.2.3 states in part: "The report shall also include assessment of the radiation doses from radioactive liquid and gaseous effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY during the report period; this assessment must be performed in accordance with Chapter 6. All assumptions used in making these assessments ( i.e., specific activity, exposure time, and location) shall be included in the report".4.2 Demonstration of Compliance The location of concern within the site boundary is the Visitors Center. The activities at the Visitor Center consist of occasional attendance at meetings and/or short visits for informational purposes.There will be no radiation dose at this location due to radioactive liquid effluents. Delineated in Table 4-1 for this location are the values of the basic data assumed in the dose assessment due to radioactive gaseous effluents. Listed in this table are distance and direction from a point midway between the center of Unit 1 and the Unit 2 reactors, the dispersion and deposition factors for any releases from the plant vent (mixed mode) and from the turbine building (ground level), and the estimated maximum occupancy factor for an individual and the assumed age group of this individual. The source term is listed in Tables 2-2A, and 2-2B for the mixed mode releases. Similarly, it is listed in tables 2-3A and 2-3B for the ground level releases.The maximum doses in units of mrem to a MEMBER OF THE PUBLIC due to their activities inside the site boundary during the reporting period are presented in Table 4-1.Page 176 of 503 Table 4-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses to a Member of the Public Due to Activities Inside the Site Boundary Unit: Site Starting: 1-Jan-2013 Ending: 31-Dec-2013 Location Name: Distance (kilometers): Sector: Occupancy Factor: Age Group: Ground Level Release Ground Level Release Mixed Mode Release Mixed Mode Release Visitor's Center Receptor 4.47E-01 SE 4.57E-04 Child Noble Gas Particulate and Radioiodine Noble Gas Particulate and Radioiodine X/Q (sec/m3): 5.93E-06 X/Q (sec/m3): 5.58E-06 X/Q (sec/m3): 7.12E-07 X/Q (sec/m3): 6.74E-07 D/Q (m-2): 2.28E-08 D/Q (m-2): 5.77E-09 Bone Liver Total Body Thyroid Kidney Lung GI-Lli NG Total Body Whole Body Dose Units mRem mRem mRem mRem mRem mRem mRem mRem mRem 1ST Quarter 1.97E-11 2.33E-07 2.33E-07 2.33E-07 2.33E-07 2.33E-07 2.33E-07 7.43E-08 3.07E-07 2ND Quarter 3.65E-11 1.32E-07 1.32E-07 1.32E-07 1.32E-07 1.32E-07 1.32E-07 9.26E-08 2.25E-07 3RD Quarter 0.OOE+00 1.66E-07 1.66E-07 1.66E-07 1.66E-07 1.66E-07 1.66E-07 4.09E-08 2.07E-07 4TH Quarter 4.57E-13 1.62E-07 1.62E-07 1.62E-07 1.62E-07 1.62E-07 1.62E-07 1.78E-07 3.40E-07 Year 5.66E-11 6.92E-07 6.92E-07 6.92E-07 6.92E-07 6.92E-07 6.92E-07 3.86E-07 1.08E-06 Page 177 of 503 Table 4-1 Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2013 Doses to a Member of the Public Due to Activities Inside the Site Boundary Unit: Site Starting: 1-Jan-2013 Ending: 31-Dec-2013 Location Name: Distance (kilometers): Sector: Occupancy Factor: Age Group: Ground Level Release Ground Level Release Ground Level Release Mixed Mode Release Mixed Mode Release Units 3&4 Construction 4.83E-01 SW 2.37E-01 Adult Noble Gas Particulate and Radioiodine Particulate and Radioiodine Noble Gas Particulate and Radioiodine X/Q (sec/m3): 1.81E-05 X/Q (sec/m3): 6.93E-06 X/Q (sec/m3): 6.96E-06 X/Q (sec/m3): 9.75E-07 X/Q (sec/m3): 9.17E-07 D/Q (m-2): 2.88E-08 D/Q (m-2): 2.88E-08 D/Q (m-2): 7.14E-09 Bone Uver Total Body Thyroid Kidney Lung GI-Lli NG Total Body Whole Body Dose Units mRem mRem mRem mRem mRem mRem mRem mRem mRem 1ST Quarter 1.37E-08 1.93E-04 1.93E-04 1.93E-04 1.93E-04 1.93E-04 1.93E-04 5.60E-05 2.49E-04 2ND Quarter 2.52E-08 1.06E-04 1.06E-04 1.06E-04 1.06E-04 1.06E-04 1.06E-04 6.59E-05 1.72E-04 3RD Quarter O.OOE+00 1.32E-04 1.32E-04 1.32E-04 1.32E-04 1.32E-04 1.32E-04 2.91E-05 1.62E-04 4TH Quarter 1.64E-10 1.29E-04 1.29E-04 1.29E-04 1.29E-04 1.29E-04 1.29E-04 1.27E-04 2.56E-04 Year 3.91E-08 5.61E-04 5.61E-04 5.61E-04 5.61E-04 5.61E-04 5.61E-04 2.78E-04 8.39E-04 Page 178 of 503 Page 179 of 503
5.0 Total
Dose from Uranium Fuel Cycle (40CFRI90)
5.1 Regulatory
Requirements ODCM 5.1 states in part that the annual (calendar year) dose or dose commitment to any MEMBER OF THE PUBLIC due to releases of radioactivity and to radiation from uranium fuel cycle sources shall be limited to less than or equal to 25 mrems to the whole body or to any organ, except the thyroid, which shall be limited to less than or equal to 75 mrems.5.2 Demonstration of Compliance No dose limits stated in ODCM Sections 2.1.3, 3.1.3, and 3.1.4 were exceeded.Therefore, compliance with 40 CFR 190 dose limits was demonstrated in accordance with the requirements of ODCM Section 5.1.3.6.0 Meteorological Data ODCM 7.2.2.2 states in part: The Radioactive Effluent Release Report shall include an annual summary of hourly meteorological data collected over the previous year.This annual summary may be either in the form of an hour-by-hour listing of wind speed, wind direction, atmospheric stability, and precipitation (if measured) on magnetic tape; or in the form of joint frequency distributions of wind speed, wind direction and atmospheric stability. In lieu of submission with the Radioactive Effluent Release Report, the licensee has the option of retaining this summary of required meteorological data on site in a file that shall be provided to the NRC upon request.7.0 Program Deviations
7.1 Inoperable
Liquid or Gaseous Effluent Monitoring Instrumentation
7.1.1 Regulatory
Requirement ODCM 7.2.2.6 states in part that the report shall include deviations from the liquid and gaseous effluent monitoring instrumentation operability requirements included in Sections 2.1.1 and 3.1.1, respectively. The report shall include an explanation as to why the inoperability of liquid or gaseous effluent monitoring instrumentation was not corrected within the specified time requirement. Page 180 of 503
7.1.2 Description
of Deviations The inoperability of liquid and gaseous effluent monitors not corrected within the specified time for this reporting period is detailed below.Overall, resources and major projects effected the amount resources that were allocated to repairing the monitors. During the first half of the year, there were two new radiation monitors installed and a forced maintenance outage. When applicable, compensatory measures were utilized: a. 1RE-12839 This monitor was out of service due to a failed sample pump and a bad heat trace circuit. Work to return to service overlapped with work for 2RE-1 2839.This monitor was returned to service after 36 days.b. 1FT-1085A This transmitter has been delayed with repair because of the unavailability of parts. A new transmitter arrived in September 2013 and was returned to service.c. IFT-12839 Due to a failed calibration, the transmitter was sent offsite for repair.As a result, it was out of service greater than 30 days.d. 1FIS-12862 The flow switch was discovered malfunctioning while performing a work order. Repair will be targeted for this year.e. 2RE-0018 The flow balance valve malfunctioned preventing the throttle of flow for the radiation monitor. The original work instructions were revised to include a total valve rebuild. The time that it took to develop new work instructions and create a clearance for the system extended the out of service time for the monitor. It has been returned to service.f. 2RE-0020B The radiation monitor's skid pump would trip intermittently. Troubleshooting and replacement of the pump lasted for approximately a week from the start date. As a result, the monitor was returned to service in 33 days.Later in the year, the motor and starter switch was replaced. This was delayed as a result of the forced maintenance outage. It has been returned to service.g. 2RE-0848 This monitor was declared out of service when the low voltage power supply failed. The CPU board was replaced. Work orders related to repairing Turbine Drain Header valves extended the out of service time beyond 30 days. The monitor is now in service.Page 181 of 503
- h. 2FT-12442 At the beginning of the year, this transmitter was declared out of service when it was found out of tolerance for voltage. The transmitter was sent offsite for repair which caused it to be out of service for > 30 days.This flow transmitter was taken out of service after failing a comparison with 2FT-12835 in September 2013. The transmitter is in service.i. AF17620A Dilution flow indication was reading incorrectly.
It is planned to be repaired this year.j. AFQ17620 This totalizer was not incrementing correctly. Due to parts obsolescence, an equivalency determination had to be performed to make the repair. It has been returned to service.7.2 Tanks Exceeding Curie Content Limits 7.2.1 Regulatory Requirements ODCM 7.2.2.6 states in part that the report shall include a description of the events leading to liquid holdup tanks or gas storage tanks exceeding the limits of Technical Specifications 5.5.12.7.2.2 Description of Deviations Limits for outdoor liquid hold-up tanks used for radioactive liquids were not exceeded during this reporting period.Limits for the gas storage tanks were not exceeded during this reporting period.8.0 Changes to the Vogtle Electric Generating Plant Offsite Dose Calculation Manual (ODCM)8.1 Regulatory Requirements ODCM 7.2.2.5 states in part that changes to the ODCM shall be submitted with the Radioactive Effluent Release Report. These changes may be due to changes in the radiological environmental monitoring program sampling locations as required by ODCM 4.1.1.2.3 or changes to dose calculation locations as required by ODCM 4.1.2.2.2. Land uses Page 182 of 503 and dose calculation locations within five miles of VEGP must be determined by a land use census as required by ODCM 4.1.2.8.2 Description of Changes Version 29 of the "OFFSITE DOSE CALCULATION MANUAL FOR SOUTHERN NUCLEAR OPERATING COMPANY VOGTLE ELECTRIC GENERATING PLANT" was released in February 2013. The following changes were made: 1) A correction to the Dose Equivalent 1-131 definition for thyroid conversion factors. The ODCM reference stated that the factors were from Table E-7 of NRC Regulatory Guide 1.109, Revision 1, 1977 while Chapter 15 of the VEGP FSAR, Table 15A-5 has a footnote that states these factors are from Table 2.1 of the EPA Federal Guidance Report 11 (EPA-520/1-88-020). The FSAR definition takes precedence over the ODCM definition. The software that uses these dose conversion factors already contained the correct conversion factors.2) Equation 2.7 contained a typo with operational signs. Variables fas and Xis should be multiplied instead of summed for the desired results.3) Action Statement 51 was revised to account for the ability to analyze fixed filter paper with gamma spectroscopy after new radiation monitors were installed for the Plant Vent System.9.0 Major Changes to Liquid, Gaseous, or Solid Radwaste Treatment Systems 9.1 Regulatory Requirements ODCM 7.2.2.7 states in part: As required by Sections 2.1.5 and 3.1.6, licensee initiated MAJOR CHANGES TO RADIOACTIVE WASTE TREATMENT SYSTEMS (liquid and gaseous) shall be reported to the Nuclear Regulatory Commission in the Radioactive Effluent Release Report covering the period in which the change was reviewed and accepted for implementation. Note 1: In lieu of inclusion in the Radioactive Effluents Release Report, this same information may be submitted as part of the annual FSAR update.PCP 12.1 states in part: Page 183 of 503 Licensee major initiated changes to the solid radioactive waste treatment system shall be reported to the Nuclear Regulatory Commission in the Radioactive Effluent Release Report for the period in which the change was implemented.
9.2 Description
of Major Changes Gaseous Radwaste System There were no major changes to the gaseous radwaste systems in the 2013 assessment period.Liquid Radwaste System Major changes to the liquid radwaste facilities are those that contribute to significant changes in release; i.e., either decreases or increases in release volume or activity/dose. There were no major changes to the liquid radwaste systems occurred during the 2013 assessment period.Solid Radwaste System There were no major changes to the solid radwaste systems in the 2013 assessment period.Page 184 of 503 Appendix A Vogtle Electric Generating Plant CARBON- 14 Carbon-14 (C-14) is a naturally-occurring radionuclide with a 5730 year half life. Nuclear weapons testing in the 1950s and 1960s significantly increased the amount of C-14 in the atmosphere. Nuclear power plants also produce C-14, but the amount is infinitesimal compared to what has been distributed in the environment due to weapons testing and what is produced by natural cosmic ray interactions. As nuclear plants have improved gaseous waste processing systems and improved fuel performance, the percentages of "principal radionuclides" in gaseous effluents have changed, and C-14 has become a larger percentage. "Principal radionuclides" are determined based on public dose contribution or the amount of activity discharged compared to other radionuclides of the same effluent type. In Revision 2 (June 2009) of Regulatory Guide 1.21 (RG 1.21), "Measuring, Evaluating, and Reporting Radioactive Material in Liquid and Gaseous Effluents and Solid Waste," the NRC recommended re-evaluating"principal radionuclides" and reporting C-14 as appropriate. In 2010 Radioactive Effluent Release Reports, virtually all U. S. nuclear power plants started reporting C-14 amounts released and resulting doses to the maximally exposed member of the public.Because C-14 is considered a hard-to-detect radionuclide which must be chemically separated from the effluent stream before it can be measured, RG 1.21 provides the option of calculating the C-14 source term based on power generation. The Electric Power Research Institute (EPRI) developed an accepted methodology for calculating C-14, and published the results in Technical Report 1021106 (December 2010), "Estimation of Carbon- 14 in Nuclear Power Plant Gaseous Effluents." Evaluation of C- 14 in radioactive liquid effluents is not required because the quantity and dose contribution has been determined to be insignificant. At Plant Vogtle, the annual quantity of C-14 released in gaseous effluents was estimated to be 12.08 Curies (per unit). Approximately 30% of the C-14 released is in the form of 1 4 C0 2 and is incorporated into plants through photosynthesis. Ingestion dose results from this pathway. The remaining 70% is estimated to be organic. Both the organic and inorganic forms of C-14 contribute to inhalation dose. A child is the maximally exposed individual, and bone dose is the highest organ dose. Using the dose calculation methodology from the Vogtle ODCM, the resulting bone dose to a child located at the controlling receptor location would be 8.46E-02 mrem in a year which is 0.56% of the regulatory limit of 15 mrem per year (per unit) to any organ due to gaseous effluents. The resulting total body dose to a child located at the controlling receptor location would be 1.69E-02 mrem in a year which is 0. 11% of the regulatory limit of 15 mrem per year (per unit) total body dose due to gaseous effluents Page 185 of 503 Appendix B Vogtle Electric Generating Plant CORRECTED REPORTS This section contains corrected reports for typos contained in the 2011 and 2012 Annual Radiological Effluent Release Reports: 2011 Report Table 2-5A/U 1 Year to Date -The exponential term for Organ doses were truncated due to formatting. The values should be E-07/E-04. Table 2-5C/Site Year to Date -Bone dose is the same as U I 2012 Report Table I-2A/U I (continuous) 3rd quarter -Gross Alpha value should be 0.Table 2-2C/Site (continuous) 4th quarter -The gas total value should be 1.19E+O 1.Table 2-3B/U2 (batch) 3 rd and 4 th quarters -H-3 values should be zero> Table 2-5C/Site Year to Date -All values were from the 2011 ARERR. They were updated to correct to 2012 values.Page 186 of 503 Table 2-5A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2011 Doses To A Member Of The Public Due To Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: 1 Starting: 1-Jan- 2011 Ending: 31-Dec-2011 Cumulative Doses Per Quarter Organ Bone GI-Lli Kidney Liver Lung Thyroid Total Body ODCM Units 7.50E+00 mRem 7.50E+00 mRem 7.50E+00 mRem 7.50E+00 mRem 7.50E+00 mRem 7.50E+00 mRem 7.50E+00 mRem 1ST Qtr 3.13E-07 1.10E-04 1.10E-04 1.10E-04 1. 1OE-04 1. 10E-04 1. 10E-04 0/h ODCM 4.18E-06 1.46E-03 1.46E-03 1.46E-03 1.46E-03 1.46E-03 1.46E-03 2ND Qtr 6.64E-09 2.43E-05 2.43E-05 2.43E-05 2.43E-05 2.43E-05 2.43E-05 0/o ODCM 8.86E-08 3.24E-04 3.24E-04 3.24E-04 3.24E-04 3.24E-04 3.24E-04 3RD Qtr 0.OOE+00 3.06E-05 3.06E-05 3.06E-05 3.06E-05 3.06E-05 3.06E-05 0/0 ODCM O.OOE+00 4.08E-04 4.08E-04 4.08E-04 4.08E-04 4.08E-04 4.08E-04 4TH Qtr 4.26E-07 1.11E-04 1.11E-04 1.11E-04 1.11E-04 1.11E-04 1.11E-04%/c ODCM 5.69E-06 1.48E-03 1.48E-03 1.48E-03 1.48E-03 1.48E-03 1.48E-03 Cumulative Doses per Year Organ ODCM Bone 1.500E+01 GI-Lli 1.500E+01 Kidney 1.500E+01 Liver 1.500E+01 Lung 1.500E+01 Thyroid 1.500E+01 Total Body 1.500E+01 Units mRem mRem mRem mRem mRem mRem mRem Year to Ending 7.465E-07 2.751E-04 2.751E-04 2.751E-04 2.751E-04 2.751E-04 2.751E-04 0/0 4.977E-06 1.834E-03 1.834E-03 1.834E-03 1.834E-03 1.834E-03 1.834E-03 Receptor Limit Maximum Maximum Maximum Maximum Maximum Maximum Maximum Individual Individual Individual Individual Individual Individual Individual ///////Child Child Child Child Child Child Child Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Dose Annual Dose Annual Dose Annual Dose Annual Dose Annual Dose Annual Dose Annual 1.21 1.21 1.21 1.21 1.21 1.21 1.21 Page 187 of 503 Table 2-5C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2011 Doses To A Member Of The Public Due To Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: Site Starting: 1-Jan- 2011 Ending: 31-Dec-2011 Cumulative Doses Per Quarter Organ ODCM Units Bone 7.50E+00 mRem GI-Lli 7.50E+00 mRem Kidney 7.50E+00 mRem Liver 7.50E+00 mRem Lung 7.50E+00 mRem Thyroid 7.50E+00 mRem Total Body 7.50E+00 mRem 1ST Qtr 3.13E-07 1.62E-04 1.62E-04 1.62E-04 1.62E-04 1.62E-04 1.62E-04%/o ODCM 4.18E-06 2.17E-03 2.17E-03 2.17E-03 2.17E-03 2.17E-03 2.17E-03 2ND Qtr 6.64E-09 1.03E-04 1.03E-04 1.03E-04 1.03E-04 1.03E-04 1.03E-04%/o ODCM 8.86E-08 1.38E-03 1.38E-03 1.38E-03 1.38E-03 1.38E-03 1.38E-03 3RD Qtr O.OOE+00 2.52E-04 2.52E-04 2.52E-04 2.52E-04 2.52E-04 2.52E-04% ODCM 0.0OE+00 3.36E-03 3.36E-03 3.36E-03 3.36E-03 3.36E-03 3.36E-03 4TH Qtr 4.26E-07 3.37E-04 3.37E-04 3.37E-04 3.37E-04 3.37E-04 3.37E-04 0/a ODCM 5.96E-06 4.97E-03 4.97E-03 4.97E-03 4.97E-03 4.97E-03 4.97E-03 Cumulative Doses per Year Organ ODCM Bone 1.500E+01 GI-Lli 1.500E+01 Kidney 1.500E+01 Liver 1.500E+01 Lung 1.500E+01 Thyroid 1.500E+01 Total Body 1.500E+01 Units mRem mRem mRem mRem mRem mRem mRem Year to Ending Date 6.164E-04 8.909E-04 8.908E-04 8.908E-04 8.908E-04 8.908E-04 8.909E-04%/o ODCM Receptor 4.109E-03 Maximum Individual 5.939E-03 Maximum Individual 5.939E-03 Maximum Individual 5.939E-03 Maximum Individual 5.939E-03 Maximum Individual 5.939E-03 Maximum Individual 5.939E-03 Maximum Individual / Child/ Child/ Child I Child I Child/ Child/ Child Limit Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Dose Annual Dose Annual Dose Annual Dose Annual Dose Annual Dose Annual Dose Annual 1.21 1.21 1.21 1.21 1.21 1.21 1.21 Page 188 of 503 Nuclides Released Fission & Activation Products No Nuclides Found Tritium H-3 Dissolved And Entrained Gases No Nuclides Found Gross Alpha Radioactivity G-Alpha Table 1-2A Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2012 Liquid Effluents Unit: 1 Starting: 1-Jan- 2012 Ending: 31-Dec-2012 Continuous Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Curies O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 Curies 9.82E-02 1.07E-01 6.30E-02 4.84E-02 Curies O.OOE+O0 O.OOE+O0 O.OOE+0O O.0OE+O0 Curies O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0*Zeroes in this table indicate that no radioactivity was present at detectable levels. See Table 1-4 for typical minimum detectable concentrations. Page 189 of 503 Table 2-2C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2012 Gaseous Effluents -Mixed Mode Level Releases Unit: Site Starting: 1-Jan- 2012 Ending: 31-Dec-2012 Continuous Mode Nuclides Released Fission Gases Kr-85M Xe-133 Xe- 135 Total For Period Units Curies Curies Curies 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 9.46E-02 4.75E+00 5.37E+00 1.10E-01 5.52E+00 6.24E+00 Curies O.OOE+00 0.OOE+00 1.02E+01 1.19E+01 lodines 1-131 Curies 0.OOE+00 0.DOE+00 0.OOE+00 0.OOE+00 8.94E-06 8.94E-06 0.OOE+00 O.OOE+00 Total For Period Particulates Co-58 Sr-89 Sr-90 Curies Curies O.OOE+00 1.13E-07 0.OOE+00 4.41E-07 3. 13E-08 4.73E-07 1.08E-07 3.07E-07 1.86E-08 4.34E-07 O.OOE+00 4.19E-08 O.OOE+00 4.19E-08 Curies O.OOE+00 Curies 1.13E-07 Total For Period Tritium H-3 Curies 2.62E+01 1.66E+01 8.38E+00 Gross Alpha No Nuclides Found Curies O.OOE+00 O.OOE+00 O.OOE+00*If Not Detected, Nuclide is Not Reported. Zeroes in this table indicate that no radioactivity was present at detectable levels.6.83E+00 0.OOE+00 Page 190 of 503 See Table 2-6 for typical minimum detectable concentrations. Table 2-3B Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2012 Gaseous Effluents -Ground Level Releases Unit: 2 Starting: 1-Jan- 2012 Ending: 31-Dec-2012 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Fission Gases No Nuclides Found Curies 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 Iodines No Nuclides Found Curies 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 Particulates No Nuclides Found Curies 0.OOE+O0 0.OOE+00 0.OOE+00 O.OOE+O0 Tritium H-3 Curies 0.OOE+00 0.OOE+O0 O.OOE+00 O.O0E+00 Gross Alpha No Nuclides Found Curies 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 Page 191 of 503 Table 2-5C Vogtle Electric Generating Plant RADIOACTIVE EFFLUENT RELEASE REPORT -2012 Doses To A Member Of The Public Due To Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: Site Starting: 1-Jan- 2012 Ending: 31-Dec-2012 Cumulative Doses Per Quarter Organ ODCM Units Bone 7.50E+00 mRem GI-Lli 7.50E+00 mRem Kidney 7.50E+00 mRem Liver 7.50E+00 mRem Lung 7.50E+00 mRem Thyroid 7.50E+00 mRem Total Body 7.50E+00 mRem 1ST Qtr 1.33E-07 5.68E-04 5.68E-04 5.68E-04 5.68E-04 5.68E-04 5.68E-04% ODCM 1.78E-06 3.63E-04 3.63E-04 3.63E-04 3.63E-04 3.63E-04 3.63E-04 2ND Qtr 1.76E-06 3.63E-04 3.63E-04 3.63E-04 3.63E-04 3.63E-04 3.63E-04% ODCM 2.35E-05 4.84E-03 4.84E-03 4.84E-03 4.84E-03 4.84E-03 4.84E-03 3RD Qtr 1. 15E-06 1.90E-04 1.90E-04 1.90E-04 1.90E-04 2.05E-04 1.90E-04 0/b ODCM 1.54E-05 2.53E-03 2.53E-03 2.53E-03 2.53E-03 2.74E-03 2.53E-03 4TH Qtr 4.93E-08 1.57E-04 1.57E-04 1.57E-04 1.57E-04 1.57E-04 1.57E-04 0/b ODCM 6.57E-07 2.09E-03 2.09E-03 2.09E-03 2.09E-03 2.09E-03 2.09E-03 Cumulative Doses per Year Organ ODCM Units Year to Ending Date 0/b ODCM Receotor Limit Bone GI-Lli Kidney Liver Lung Thyroid Total Body 1.500E+01 mRem 1.50015+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 1.500E+01 mRem mRem mRem mRem mRem mRem 7.465E-07 8.909E-04 8.908E-04 8.908E-04 8.908E-04 8.908E-04 8.909E-04 2.064E-05 5.939E-03 5.939E-03 5.939E-03 5.939E-03 5.939E-03 5.939E-03 Maximum Individual Maximum Individual Maximum Individual Maximum Individual Maximum Individual Maximum Individual Maximum Individual / Child/ Child/ Child/ Child/ Child I Child/ Child Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Iodine/Part Dose Annual 1.21 Dose Annual 1.21 Dose Annual 1.21 Dose Annual 1.21 Dose Annual 1.21 Dose Annual 1.21 Dose Annual 1.21 Page 192 of 503 Appendix C VEGP ODCM Version 29 OFFSITE DOSE CALCULATION MANUAL FOR SOUTHERN NUCLEAR OPERATING COMPANY VOGTLE ELECTRIC GENERATING PLANT Version 29 February 2013 Page iii of 503 TABLE OF CONTENTS PAGE T A B LE O F C O N T E N T S ............................................................................................................... i L IS T O F T A B L E S ...................................................................................................................... iv L IS T O F F IG U R E S .................................................................................................................... vi R E F E R E N C E S ........................................................................................................................ v ii C H A PT E R 1: IN T R O D U C T IO N ............................................................................................. 1-1 C HA PTER 2: LIQ U ID EFFLU ENTS ....................................................................................... 2-1 2.1 LIMITS OF OPERATION 2-1 2.1.1 Liquid Effluent Monitoring Instrumentation Control 2-1 2.1.2 Liquid Effluent Concentration Control 2-7 2.1.3 Liquid Effluent Dose Control 2-10 2.1.4 Liquid Radwaste Treatment System Control 2-11 2.1.5 Major Changes to Liquid Radioactive Waste Treatment Systems 2-12 2.2 LIQUID RADWASTE TREATMENT SYSTEM 2-13 2.3 LIQUID EFFLUENT MONITOR SETPOINTS 2-17 2.3.1 General Provisions Regarding Setpoints 2-17 2.3.2 Setpoints for Radwaste System Discharge Monitors 2-19 2.3.3 Setpoints for Monitors on Normally Low-Radioactivity Streams 2-25 2.4 LIQUID EFFLUENT DOSE CALCULATIONS 2-26 2.4.1 Calculation of Dose 2-26 2.4.2 Calculation of Ai, 2-27 2.4.3 Calculation of CF~v 2-28 2.5 LIQUID EFFLUENT DOSE PROJECTIONS 2-37 2.5.1 Thirty-One Day Dose Projections 2-37 2.5.2 Dose Proiections for Specific Releases 2-37 2.6 DEFINITIONS OF LIQUID EFFLUENT TERMS 2-38 CHAPTER 3: GASEO US EFFLUENTS ................................................................................. 3-1 3.1 LIMITS OF OPERATION 3-1 3.1.1 Gaseous Effluent Monitoring Instrumentation Control 3-1 3.1.2 Gaseous Effluent Dose Rate Control 3-7 3.1.3 Gaseous Effluent Air Dose Control 3-10 3.1.4 Control on Gaseous Effluent Dose to a Member of the Public 3-11 3.1.5 Gaseous Radwaste Treatment System Control 3-12 3.1.6 Manor Changes to Gaseous Radioactive Waste Treatment Systems 3-13 i VER 29 TABLE OF CONTENTS (continued) PAGE 3.2 GASEOUS WASTE PROCESSING SYSTEM 3-14 3.3 GASEOUS EFFLUENT MONITOR SETPOINTS 3-20 3.3.1 General Provisions Regarding Noble Gas Monitor Setpoints 3-20 3.3.2 Setpoint for the Final Noble Gas Monitor on Each Release Pathway 3-22 3.3.3 Setpoints for Noble Gas Monitors on Effluent Source Streams 3-25 3.3.4 Determination of Allocation Factors, AG 3-27 3.3.5 Setpoints for Noble Gas Monitors with Special Requirements 3-29 3.3.6 Setpoints for Particulate and Iodine Monitors 3-29 3.4 GASEOUS EFFLUENT COMPLIANCE CALCULATIONS 3-30 3.4.1 Dose Rates at and Beyond the Site Boundary 3-30 3.4.2 Noble Gas Air Dose at or Beyond Site Boundary 3-31 3.4.3 Dose to a Member of the Public at or Beyond Site Boundary 3-35 3.4.4 Dose Calculations to Support Other Requirements 3-38 3.5 GASEOUS EFFLUENT DOSE PROJECTIONS 3-44 3.5.1 Thirty-One Day Dose Proiections 3-44 3.5.2 Dose Proiections for Specific Releases 3-45 3.6 DEFINITIONS OF GASEOUS EFFLUENT TERMS 3-46 CHAPTER 4: RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM .................... 4-1 4.1 LIMITS OF OPERATION 4-1 4.1.1 Radiological Environmental Monitoring 4-1 4.1.2 Land Use Census 4-9 4.1.3 Interlaboratory Comparison Program 4-10 4.2 RADIOLOGICAL ENVIRONMENTAL MONITORING LOCATIONS 4-11 CHAPTER 5: TOTAL DOSE DETERMINATIONS .................................................................. 5-1 5.1 LIMIT OF OPERATION 5-1 5.1.1 Applicabilitv 5-1 5.1.2 Actions 5-1 5.1.3 Surveillance Requirements 5-1 5.1.4 Basis 5-1 5.2 DEMONSTRATION OF COMPLIANCE 5-3 CHAPTER 6: POTENTIAL DOSES TO MEMBERS OF THE PUBLIC DUE TO THEIR ACTIVITIES INSIDE THE SITE BOUNDARY ................................................... 6-1 6.1 REQUIREMENT FOR CALCULATION 6-1 6.2 CALCULATIONAL METHOD 6-1 2 VER 29 TABLE OF CONTENTS (continued) PAGE C H A PT E R 7: R E P O R T S ....................................................................................................... 7-1 7.1 ANNUAL RADIOLOGICAL ENVIRONMENTAL SURVEILLANCE REPORT 7-1 7.1.1 Requirement for Report 7-1 7.1.2 Report Contents 7-1 7.2 RADIOACTIVE EFFLUENT RELEASE REPORT 7-3 7.2.1 Requirement for Report 7-3 7.2.2 Report Contents 7-3 7.3 MONTHLY OPERATING REPORT 7-6 7.4 SPECIAL REPORTS 7-6 CHAPTER 8: METEOROLOGICAL MODELS ....................................................................... 8-1 8.1 ATMOSPHERIC DISPERSION 8-1 8.1.1 Ground-Level Releases 8-1 8.1.2 Elevated Releases 8-2 8.1.3 Mixed-Mode Releases 8-4 8.2 RELATIVE DEPOSITION 8-5 8.2.1 Ground-Level Releases 8-5 8.2.2 Elevated Releases 8-5 8.2.3 Mixed-Mode Releases 8-6 8.3 ELEVATED PLUME DOSE FACTORS 8-6 CHAPTER 9: METHODS AND PARAMETERS FOR CALCULATION OF GASEOUS EFFLUENT PATHWAY DOSE FACTORS, Raipj ........................................... 9-1 9.1 INHALATION PATHWAY FACTOR 9-1 9.2 GROUND PLANE PATHWAY FACTOR 9-2 9.3 GARDEN VEGETATION PATHWAY FACTOR 9-3 9.4 GRASS-COW-MILK PATHWAY FACTOR 9-6 9.5 GRASS-GOAT-MILK PATHWAY FACTOR 9-9 9.6 GRASS-COW-MEAT PATHWAY FACTOR 9-12 CHAPTER 10: DEFINITIONS OF EFFLUENT CONTROL TERMS ........................................ 10-1 10.1 TERMS SPECIFIC TO THE ODCM 10-1 10.2 TERMS DEFINED IN THE TECHNICAL SPECIFICATIONS 10-5 3 VER 29 LIST OF TABLES Table 2-1.Table 2-2.Table 2-3.Table 2-4.Table 2-5.Table 2-6.Table 2-7.Table 2-8.Table 3-1.Table 3-2.Table 3-3.Table 3-4.Table 3-5.Table 3-6.Table 3-7.Table 3-8.Table 3-9.Table 3-10.Table 3-11.Table 3-12.Table 4-1.Radioactive Liquid Effluent Monitoring Instrumentation Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements Radioactive Liquid Waste Sampling and Analysis Program Applicability of Liquid Monitor Setpoint Methodologies Parameters for Calculation of Doses Due to Liquid Effluent Releases Element Transfer Factors Adult Ingestion Dose Factors Site-Related Ingestion Dose Factors, AT, Radioactive Gaseous Effluent Monitoring Instrumentation Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements Radioactive Gaseous Waste Sampling and Analysis Program Applicability of Gaseous Monitor Setpoint Methodologies Dose Factors for Exposure to a Semi-Infinite Cloud of Noble Gases Dose Factors for Exposure to Direct Radiation from Noble Gases in an Elevated Finite Plume Attributes of the Controlling Receptor Raipj for Ground Plane Pathway, All Age Groups Raipj for Inhalation Pathway, Child Age Group Raipj for Inhalation Pathway, Adult Age Group Raipj for Cow Meat Pathway, Child Age Group Raipj for Garden Vegetation, Child Age Group Radiological Environmental Monitoring Program PAGE 2-3 2-5 2-8 2-18 2-30 2-31 2-32 2-35 3-3 3-5 3-8 3-21 3-33 3-34 3-37 3-39 3-40 3-41 3-42 3-43 4-3 4 VER 29 LIST OF TABLES (Continued) Table 4-2.Table 4-3.Table 4-4.Table 4-5 Table 6-1.Table 8-1.Table 9-1.Table 9-2.Table 9-3.Table 9-4.Table 9-5.Table 9-6.Table 9-7.Table 9-8.Table 9-9.Table 9-10.Table 9-11.Table 9-12.Table 9-13.Table 9-14.Table 9-15.Reporting Levels for Radioactivity Concentrations in Environmental Samples Values for the Minimum Detectable Concentration (MDC)Radiological Environmental Monitoring Locations Groundwater Monitoring Locations Attributes of Member of the Public Receptor Locations Inside the Site Boundary Terrain Elevation Above Plant Site Grade Miscellaneous Parameters for the Garden Vegetation Pathway Miscellaneous Parameters for the Grass-Cow-Milk Pathway Miscellaneous Parameters for the Grass-Goat-Milk Pathway Miscellaneous Parameters for the Grass-Cow-Meat Pathway Individual Usage Factors Stable Element Transfer Data Inhalation Dose Factors for the Infant Age Group Inhalation Dose Factors for the Child Age Group Inhalation Dose Factors for the Teenager Age Group Inhalation Dose Factors for the Adult Age Group Ingestion Dose Factors for the Infant Age Group Ingestion Dose Factors for the Child Age Group Ingestion Dose Factors for the Teenager Age Group Ingestion Dose Factors for the Adult Age Group External Dose Factors for Standing on Contaminated Ground PAGE 4-7 4-8 4-12 4-15 6-2 8-7 9-5 9-8 9-11 9-14 9-15 9-16 9-17 9-20 9-23 9-26 9-29 9-32 9-35 9-38 9-41 5 VER 29 LIST OF FIGURES Figure 2-1.Figure 2-2.Figure 2-3.Figure 3-1.Figure 3-2.Figure 3-3.Figure 3-4.Figure 3-5.Figure 4-1.Figure 4-2.Figure 4-3.Figure 4-4.Figure 4-5 Figure 8-1.Figure 8-2.Figure 8-3.Figure 8-4.Figure 8-5.Figure 8-6.Figure 8-7.Figure 8-8.Figure 8-9.Figure 8-10.Unit 1 Liquid Radwaste Treatment System Unit 2 Liquid Radwaste Treatment System Liquid Radwaste Discharge Pathways Schematic Diagram of the Gaseous Radwaste Treatment System Schematic Diagram of the Unit 1 Plant Vent Release Pathway Schematic Diagram of the Unit 2 Plant Vent Release Pathway Schematic Diagram of the Turbine Building Vent Release Pathway (Typical of Both Units)Schematic Diagram of the Radwaste Processing Facility Ventilation Release Pathway Terrestrial Stations Near Site Boundary Terrestrial Stations and Aquatic Stations, 0-5 Miles Terrestrial Stations Beyond 5 Miles Drinking Water Stations Groundwater Monitoring Wells Vertical Standard Deviation of Material in a Plume (a,)Terrain Recirculation Factor (Kr)Plume Depletion Effect for Ground Level Releases Plume Depletion Effect for 30-Meter Releases Plume Depletion Effect for 60-Meter Releases Plume Depletion Effect for 100-Meter Releases Relative Deposition for Ground-Level Releases Relative Deposition for 30-Meter Releases Relative Deposition for 60-Meter Releases Relative Deposition for 100-Meter (or Greater) Releases PAGE 2-14 2-15 2-16 3-15 3-16 3-17 3-18 3-19 4-16 4-17 4-18 4-19 4-20 8-8 8-9 8-10 8-11 8-12 8-13 8-14 8-15 8-16 8-17 6 VER 29 REFERENCES
- 1. J.S. Boegli, R.R. Bellamy, W.L. Britz, and R.L. Waterfield, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants," NUREG-0133, October 1978.2. "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR 50, Appendix I," U.S. NRC Regulatory Guide 1.109, March 1976.3. "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR 50, Appendix I," U.S. NRC Regulatory Guide 1.109, Revision 1, October 1977.4. "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors," U.S. NRC Regulatory Guide 1.111, March 1976.5. "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors," U.S. NRC Regulatory Guide 1.111, Revision 1, July 1977.6. "Estimating Aquatic Dispersion of Effluents from Accidental and Routine Reactor Releases for the Purpose of Implementing Appendix I," U.S. NRC Regulatory Guide 1.113, April 1977.7. W.R. Stokes Ill, T.W. Hale, J.L. Pearman, and G.R. Buell, "Water Resources Data, Georgia, Water Year 1983," U.S. Geological Survey Water Data Report GA-83-1, June 1984.8. Direct communication with the Water Resources Division, U.S. Geological Survey, U.S.Department of the Interior, February 1985.9. Bernd Kahn, et al., "Bioaccumulation of P-32 in Bluegill and Catfish," NUREG/CR-3981, February 1985.10. Memo from S.E. Ewald, Georgia Power Company, to C.C. Eckert, Georgia Power Company, May 9, 1988.11. Voqtle Electric Generating Plant Units 1 and 2 Final Safety Analysis Report, Georgia Power Company.12. Voqtle Electric Generating Plant Units 1 and 2 Environmental Report -Operating License Stage, Georgia Power Company.13. Memo from A.C. Stalker, Georgia Power Company, to D.F. Hallman, Georgia Power Company, May 9, 1988.14. Voaqtle Electric Generating Plant Land Use Survey -1988, Georgia Power Company, April 1988.15. Letter to Southern Company Services from Pickard, Lowe, and Garrick, Inc., Washington, D.C., April 27,1988.7 VER 29
- 16. Letter to Bill Ollinger, Georgia Power Company, from T.L. Broadwell, Georgia Power Company, Atlanta, Georgia, June 22, 1988.17. Letter to Bill Ollinger, Georgia Power Company, from R.D. Just, Georgia Power Company, Atlanta, Georgia, July 8, 1988.18. L.A. Currie, Lower Limit of Detection:
Definition and Elaboration of a Proposed Position of Radiolo-gical Effluent and Environmental Measurements, U.S. NRC Report NUREG/CR-4007, 1984.19. "Radiological Assessment Branch Technical Position," U.S. Nuclear Regulatory Commission, Revision 1, November 1979.20. D.C. Kocher, "Radioactive Decay Data Tables," U.S. DOE Report DOE/TIC-11026, 1981.21. J.E. Till and H.R. Meyer, eds., Radiological Assessment, U.S. NRC Report NUREG/CR-3332, 1983.22. Letter to Bill Ollinger, Southern Nuclear Operating Company, from Gary D. Johnson, Georgia Power Company, December 21, 1995.23. Letter to Mary Beth Lloyd, Southern Nuclear Operating Company, from Steven Bearce, Southern Company Services, February 2, 2009.8 VER 29 VEGP ODCM CHAPTER 1 INTRODUCTION The Offsite Dose Calculation Manual is a supporting document of the Technical Specifications. As such, it describes the methodology and parameters to be used in the calculation of offsite doses due to radioactive liquid and gaseous effluents, and in the calculation of liquid and gaseous effluent monitoring instrumentation alarm setpoints. In addition, it contains the following:
- The controls required by the Technical Specifications, governing the radioactive effluent and radiological environmental monitoring programs.* Schematics of liquid and gaseous radwaste effluent treatment systems, which include designation of release points to UNRESTRICTED AREAS.* A list and maps indicating the specific sample locations for the Radiological Environmental Monitoring Program." Specifications and descriptions of the information that must be included in the Annual Radiological Environmental Operating Report and the Radioactive Effluent Release Report required by the Technical Specifications.
The ODCM will be maintained at the plant for use as a reference guide and training document of accepted methodologies and calculations. Changes in the calculational methods or parameters will be incorporated into the ODCM in order to ensure that it represents current methodology in all applicable areas. Any computer software used to perform the calculations described will be maintained current with the ODCM.Equations and methods used in the ODCM are based on those presented in NUREG-0133 (Reference 1), in Regulatory Guide 1.109 (References 2 and 3), in Regulatory Guide 1.111 (References 4 and 5), and in Regulatory Guide 1.113 (Reference 6).1-1 VER 29 VEGP ODCM CHAPTER 2 LIQUID EFFLUENTS 2.1 LIMITS OF OPERATION The following Liquid Effluent Controls implement requirements established by Technical Specifications Section 5.0. Terms printed in all capital letters are defined in Chapter 10.2.1.1 Liquid Effluent Monitoring Instrumentation Control In accordance with Technical Specification 5.5.4.a, the radioactive liquid effluent monitoring instrumentation channels shown in Table 2-1 shall be OPERABLE with their alarm/trip setpoints set to ensure that the limits specified in Section 2.1.2 are not exceeded. The alarm/trip setpoints of these channels shall be determined in accordance with Section 2.3.2.1.1.1 Applicability This limit applies at all times.2.1.1.2 Actions With a radioactive liquid effluent monitoring instrumentation channel alarm/trip setpoint less conservative than required by the above control, immediately suspend the release of radioactive liquid effluents monitored by the affected channel, declare the channel inoperable, or change the setpoint to a conservative value.With less than the minimum number of radioactive liquid effluent monitoring instrumentation channels OPERABLE, take the ACTION shown in Table 2-1. Restore the INOPERABLE instrumentation to OPERABLE status within 30 days, or if unsuccessful, explain in the next Radioactive Effluent Release Report, per Technical Specification 5.6.3, why this inoperability was not corrected in a timely manner.This control does not affect shutdown requirements or MODE changes.2.1.1.3 Surveillance Requirements Each radioactive liquid effluent monitoring instrumentation channel shall be demonstrated OPERABLE by performance of the CHANNEL CHECK, SOURCE CHECK, CHANNEL CALIBRATION, and CHANNEL OPERATIONAL TEST operations at the frequencies shown in Table 2-2. Specific instrument numbers are provided in parentheses for information only. The numbers apply to each unit. These numbers will help to identify associated channels or loops and are not intended to limit the requirements to the specific instruments associated with the number.2-1 VER 29 2-1 VER 29 VEGP ODCM 2.1.1.4 Basis The radioactive liquid effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in liquid effluents during actual or potential releases of liquid effluents. The Alarm/Trip Setpoints for these instruments shall be calculated and adjusted in accordance with the methodology and parameters in Section 2.3 to ensure that the alarm/trip will occur prior to exceeding the limits of Section 2.1.2. The OPERABILITY and use of this instrumentation is consistent with the requirements of General Design Criteria 60, 63, and 64 of Appendix A to 10 CFR Part 50.2-2 VER 29 VEGP ODCM Table 2-1. Radioactive Liquid Effluent Monitoring Instrumentation OPERABILITY Requirementsa Instrument Minimum Channels Operable ACTION 1. Radwaste Monitors Providing Alarm and Automatic Termination of Release a. Liquid Radwaste Effluent Line (RE-0018) 1 37 b. Steam Generator Blowdown Effluent Line 1 38 (RE-0021)c. Turbine Building Effluent Line (RE-0848) 1 38 2. Radwaste Monitors Providing Alarm, but Not Automatic Termination of Release NSCW Effluent Line (RE-0020 A) 1 39 NSCW Effluent Line (RE-0020 B) 1 39 3. Flowrate Measurement Devices a. Liquid Radwaste Effluent Line (FT-0018), 1 40 (FT-1084A1B), or (FT-1085A/B)
- b. Steam Generator Blowdown Effluent Line 1 40 (FT-0021)c. Flow to Blowdown Sump (AFQI-7620, F17620A) 1 40 a. All requirements in this table apply to each unit.2-3 VER 29 VEGP ODCM Table 2-1 (contd). Notation for Table 2-1 -ACTION Statements ACTION 37 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases may continue provided that prior to initiating a release: a. The local radiation monitor reading (if functional) is recorded at least once per 12 hours during the release or at least two independent samples are analyzed in accordance with Section 2.1.2.3, and b. At least two technically qualified members of the Facility Staff independently verify the discharge line valving and the release rate calculations.
Otherwise, suspend release of radioactive effluents via this pathway.ACTION 38 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway may continue provided the local radiation monitor reading (if functional) is recorded at least once per 12 hours or grab samples are analyzed for gross radioactivity at a MINIMUM DETECTABLE CONCENTRATION no higher than 1 x 10-7 ltCi/mL using gross beta/gamma counting or 5 x 10-7 ýiCi/mL for the principal gamma emitters using gamma-ray spectroscopy.
- a. At least once per 12 hours when the specific activity of the secondary coolant is greater than 0.01 pCi/gram DOSE EQUIVALENT 1-131.b. At least once per 24 hours when the specific activity of the secondary coolant is less than or equal to 0.01 fiCi/gram DOSE EQUIVALENT I-131.ACTION 39 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway may continue provided that, at least once per 12 hours, the local radiation monitor reading (if functional) is recorded or grab samples are collected and analyzed for radioactivity at a MINIMUM DETECTABLE CONCENTRATION no higher than 1 x 10-7 ItCi/mL using gross beta/gamma counting or 5 x 10-7 RtCi/mL for the principal gamma emitters using gamma-ray spectroscopy.
ACTION 40 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway 2-4 VER 29 VEGP ODCM may continue provided the flowrate is estimated at least once per 4 hours during actual releases. Pump curves generated in place may be used to estimate flow.2-5 VER29 2-5 VER 29 VEGP ODCM Table 2-2. Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements Surveillance Requirementsd CHANNEL CHANNEL Instrument CHANNEL SOURCE CALIBRA- OPERATIONAL CHECK CHECK TION TEST 1. Radwaste Monitors Providing Alarm and Automatic Termination of Release a. Liquid Radwaste Effluent Line (RE-0018) D P Rb Ra(l)b. Steam Generator Blowdown Effluent Line (RE-0021) D M Rb Ra(l)c. Turbine Building Effluent Line (RE-0848) D M Rb Ra(l)2. Radwaste Monitors Providing Alarm, but Not Automatic Termination of Release NSCW Effluent Line (RE-0020 A&B) D M Rb Ra(2)3. Flowrate Measurement Devices a. Liquid Radwaste Effluent Line (FT-001 8), (FT-1084A/B), or (FT- 1085A/B) Dc NA R NA b. Steam Generator Blowdown Effluent Line (FT-0021) Dc NA R NA c. Flow to Blowdown Sump (AFQI-7620, F17620A) Dc NA R Q 2-5 VER 29 VEGP ODCM Table 2-2 (contd). Notation for Table 2-2 a. In addition to the basic functions of a CHANNEL OPERATIONAL TEST (Section 10.2): (1) The CHANNEL OPERATIONAL TEST shall also demonstrate that automatic isolation of this pathway and control room annunciation occurs (for item a. below only); and control room CRT indication occurs (if any of the following conditions exist): (a) Instrument indicates measured levels above the alarm/trip setpoint;(b) Instrument indicates an "Equipment Trouble" alarm;(c) Instrument indicates a "Low" alarm; or (d) Instrument indicates channel "Deactivated". (2) The CHANNEL OPERATIONAL TEST shall also demonstrate that control room annunciation occurs (for item a. below only); and that control room CRT indication occurs (if any of the following conditions exist): (a) Instrument indicates measured levels above the alarm/trip setpoint;(b) Instrument indicates an "Equipment Trouble" alarm;(c) Instrument indicates a "Low" alarm; or (d) Instrument indicates channel "Deactivated".
- b. The initial CHANNEL CALIBRATION shall be performed using one or more of the reference standards certified by the National Institute of Standards and Technology or using standards that have been obtained from suppliers that participate in measurements assurance activities with NIST. These standards shall permit calibrating the system over its intended range of energy and measurement range. For subsequent CHANNEL CALIBRATION, sources that have been related to the initial calibration shall be used.c. CHANNEL CHECK shall consist of verifying indication of flow during periods of release. CHANNEL CHECK shall be made at least once per 24 hours on days on which continuous, periodic, or batch releases are made.2-6 VER 29 VEGP ODCM d. All requirements in this table apply to each unit.2-7 VER 29 VEGP ODCM 2.1.2 Liquid Effluent Concentration Control In accordance with Technical Specifications 5.5.4.b and 5.5.4.c, the concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS shall be limited at all times to ten times the concentrations specified in 10 CFR 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 1 x 10 -4 pCi/mL total activity.2.1.2.1 Applicability This limit applies at all times.2.1.2.2 Actions With the concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS exceeding the limits stated in Section 2.1.2, immediately restore the concentration to within the stated limits.This control does not affect shutdown requirements or MODE changes.2.1.2.3 Surveillance Requirements The radioactivity content of each batch of radioactive liquid waste shall be determined by sampling and analysis in accordance with Table 2-3. The results of radioactive analyses shall be used with the calculational methods in Section 2.3 to assure that the concentration at the point of release is maintained within the limits of Section 2.1.2.2.1.2.4 Basis This control is provided to ensure that the concentration of radioactive materials released in liquid waste effluents to UNRESTRICTED AREAS will be less than ten times the concentration levels specified in 10 CFR 20, Appendix B, Table 2, Column 2.This limitation provides additional assurance that the levels of radioactive materials in bodies of water in UNRESTRICTED AREAS will result in exposures within (1) the Section II.A design objectives of Appendix 1, 10 CFR 50, to a MEMBER OF THE PUBLIC, and (2) the limits of 10 CFR 20.1301 to the population.
The concentration limit for dissolved or entrained noble gases is based upon the assumption that Xe-1 35 is the controlling radioisotope and its MPC in air (submersion) was converted to an equivalent concentration in water using the methods described in International Commission on Radiological Protection (ICRP) Publication 2 (1959). The resulting concentration of 2 x 104 was then multiplied by the ratio of the effluent concentration limit for Xe-1 35, stated in Appendix B, Table 2, Column 1 of 10 CFR 20 (paragraphs 20.1001 to 20.2401), to the MPC for Xe-135, stated in Appendix B, Table II, Column 1 of 10 CFR 20 (paragraphs 20.1 to 20.601), to obtain the limiting concentration of 1 x 104 ptCi/mL.2-7 VER 29 VEGP ODCM 2-8 VER29 2-8 VER 29 VEGP ODCM Table 2-3.Radioactive Liquid Waste Sampling and Analysis Program_-_ Sam pling and Analysis Requirementsa b MINIMUM MINIMUM DETECTABLE CONCENTRA-Minimum TO MC Liquid Release Sampling Analysis Type of Activity TION (MDC)Type FREQUENCY FREQUENCY Analysis (jiCi/mL)A. BATCH RELEASES PRINCIPAL 5 E-7 GAMMA EMITTERS P P Each BATCH Each BATCH 1-131 1 E-6 1. Waste Monitor Dissolved and 1 E-5 Tank p Entrained Gases One BATCH/M M (Gamma Emitters)2. Drainage of H-3 I E-5 System P M Each BATCH COMPOSITE Gross Alpha 1 E-7 Sr-89, Sr-90 5 E-8 P Q Each BATCH COMPOSITE Fe-55 I E-6 B. CONTINUOUS RELEASES PRINCIPAL 5 E-7 GAMMA EMITTERS W Continuous COMPOSITE 1-131 1 E-6 Dissolved and 1 E-5 M Entrained Gases Grab Sample M (Gamma Emitters)Waste Water H-3 1 E-5 Retention Basinc M Continuous COMPOSITE Gross Alpha 1 E-7 Sr-89, Sr-90 5 E-8 Q Continuous COMPOSITE Fe-55 1 E-6 2-8 VER 29 VEGP ODCM Table 2-3 (contd). Notation for Table 2-3 a. All requirements in this table apply to each unit.b. Terms printed in all capital letters are defined in Chapter 10.c. The VVWRB will not be considered a release point until there is a confirmed primary to secondary leak. Once a primary to secondary leak has been confirmed, this composite shall be analyzed as specified until the leak is repaired. This surveillance will continue until three consecutive weekly composite samples have shown no activity above the MDC.2-10 VER 29 VEGP ODCM 2-10 VER 29 VEGP ODCM 2.1.3 Liquid Effluent Dose Control In accordance with Technical Specifications 5.5.4.d and 5.5.4.e, the dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive materials in liquid effluents released, from each unit, to UNRESTRICTED AREAS shall be limited: a. During any calendar quarter to less than or equal to 1.5 mrem to the total body and to less than or equal to 5 mrem to any organ, and b. During any calendar year to less than or equal to 3 mrem to the total body and to less than or equal to 10 mrem to any organ.2.1.3.1 Applicability These limits apply at all times.2.1.3.2 Actions With the calculated dose from the release of radioactive materials in liquid effluents exceeding any of the limits of Section 2.1.3., prepare and submit to the Nuclear Regulatory Commission within 30 days a special report which identifies the cause(s) for exceeding the limit(s); defines the corrective actions to be taken to reduce the releases;and defines the proposed corrective actions to be taken to assure that subsequent releases will be in compliance with the limits of Section 2.1.3.This control does not affect shutdown requirements or MODE changes.2.1.3.3 Surveillance Requirements At least once per 31 days, cumulative dose contributions from liquid effluents for the current calendar quarter and the current calendar year shall be determined, for each unit, in accordance with Section 2.4.2.1.3.4 Basis This control is provided to implement the requirements of Sections II.A, III.A and IV.A of Appendix 1, 10 CFR Part 50. The limits stated in Section 2.1.3 implement the guides set forth in Section Il.A of Appendix I. The ACTIONS stated in Section 2.1.3.2 provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive material in liquid effluents will be kept "as low as is reasonably achievable." Also, for fresh water sites with drinking water supplies that can be potentially affected by plant operations, there is reasonable assurance that the operation of the facility will not result in radionuclide concentrations in the finished drinking water that are in excess of the requirements of 40 CFR Part 141. The dose calculations in Section 2.4 implement the requirements in 2-10 VER 29 VEGP ODCM Section III.A of Appendix I, which state that conformance with the guides of Appendix I be shown by calculational procedures based on models and data, such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated. The equations specified in Section 2.4 for calculating the doses due to the actual release rates of radioactive materials in liquid effluents are consistent with the 2-11 VER 29 VEGP ODCM methodology provided in Regulatory Guide 1.109 (Reference
- 3) and Regulatory Guide 1.113 (Reference 6).This control applies to the release of liquid effluents from each unit at the site. The liquid effluents from shared LIQUID RADWASTE TREATMENT SYSTEMs are to be proportioned between the units.2.1.4 Liquid Radwaste Treatment System Control In accordance with Technical Specification 5.5.4.f, the LIQUID RADWASTE TREATMENT SYSTEM shall be OPERABLE.
The appropriate portions of the system shall be used to reduce radioactivity in liquid wastes prior to their discharge when the projected doses due to the liquid effluent, from each unit, to UNRESTRICTED AREAS would exceed 0.06 mrem to the total body or 0.2 mrem to any organ of a MEMBER OF THE PUBLIC in 31 days.2.1.4.1 Applicability This limit applies at all times.2.1.4.2 Actions With radioactive liquid waste being discharged without treatment and in excess of the above limits and any portion of the LIQUID RADWASTE TREATMENT SYSTEM not in operation, prepare and submit to the Nuclear Regulatory Commission within 30 days a special report which includes the following information:
- a. Explanation of why liquid radwaste was being discharged without treatment, identification of any inoperable equipment or subsystems and the reason for the inoperability, b. Action(s) taken to restore the inoperable equipment to OPERABLE status, and c. Summary description of action(s) taken to prevent a recurrence.
This control does not affect shutdown requirements or MODE changes.2.1.4.3 Surveillance Requirements Doses due to liquid releases to UNRESTRICTED AREAS shall be projected at least once per 31 days, in accordance with Section 2.5, during periods in which the LIQUID RADWASTE TREATMENT SYSTEMs are not being fully utilized.The LIQUID RADWASTE TREATMENT SYSTEM shall be demonstrated OPERABLE by meeting the controls of Sections 2.1.2 and 2.1.3.2-11 VER 29 VEGP ODCM 2.1.4.4 Basis The OPERABILITY of the LIQUID RADWASTE TREATMENT SYSTEM ensures that this system will be available for use whenever liquid effluents require treatment prior to release to the UNRESTRICTED AREAS. The requirement that the appropriate portions of this system be used when specified provides assurance that the releases of radioactive materials in liquid effluents will be kept "as low as is reasonably achievable." This control implements the requirements of 10 CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR Part 50, and the design objective given in Section lI.D of Appendix I to 10 CFR Part 50. The specified limits governing the use of appropriate portions of the LIQUID RADWASTE TREATMENT SYSTEM were specified as a suitable fraction of the dose design objectives set forth in Section II.A of Appendix 1, 10 CFR Part 50, for liquid effluents. This control applies to the release of radioactive materials in liquid effluents from each unit at the site. For units with shared radwaste systems, the liquid effluents from the shared system are to be proportioned among the units sharing that system.2.1.5 Major Changes to Liquid Radioactive Waste Treatment Systems Licensee initiated MAJOR CHANGES TO LIQUID RADIOACTIVE WASTE TREATMENT SYSTEMS: a. Shall be reported to the Nuclear Regulatory Commission in the Radioactive Effluent Release Report for the period in which the change was implemented. The discussion of each change shall contain the information described in Section 7.2.2.7.b. Shall become effective upon review and approval by the Vice President -Plant.2-12 VER 29 VEGP ODCM 2.2 LIQUID RADWASTE TREATMENT SYSTEM The Vogtle Electric Generating Plant is located on the west bank of the Savannah River approximately 151 river miles from the Atlantic Ocean. There are two pressurized water reactors on the site. Each unit is served by a separate LIQUID RADWASTE TREATMENT SYSTEM; however, certain components are shared between the two systems. Schematics of the LIQUID RADWASTE TREATMENT SYSTEMs are presented in Figure 2-1 and Figure 2-2. Liquid discharge pathways are shown in Figure 2-3.All liquid radwastes treated by the LIQUID RADWASTE TREATMENT SYSTEM are collected in 5,000-gallon or 20,000-gallon waste monitor tanks. Releases from the waste monitor tanks are to the discharge line from the blowdown sump, and from there to the Savannah River. The blowdown sump also receives input from the waste water retention basins, turbine plant cooling water blowdown, and nuclear service cooling water blowdown. Additional dilution water is available from the cooling tower makeup water bypass line.Although no significant quantities of radioactivity are expected in the nuclear service cooling water, the steam generator blowdown processing system, or the turbine building drain system, these effluent pathways are monitored as a precautionary measure. The monitors serving the latter two pathways provide for automatic termination of releases from these systems in the event that radioactivity is detected above predetermined levels. These two systems discharge to the waste water retention basin. Sampling and analysis of releases via all three of these pathways must be sufficient to ensure that the liquid effluent dose limits specified in the controls of Section 2.1.3 are not exceeded.2-13 VER 29 VEGP ODCM To Unit 2 Filter Demin Waste Monitor Waste Monitor Tank: Tank: 5,000 gal 20,000 gal I I To Figure 2-1. Unit 1 Liquid Radwaste Treatment System 2-14 VER 29 VEGP ODCM from Laundry and Hot Shower Tank (Unit 1)Filter D ni n i Waste Monitor Waste Monitor Tank: Tank: 5,000 gal 20,000 gal To Discharge Figure 2-2. Unit 2 Liquid Radwaste Treatment System 2-15 VER 29 VEGP ODCM River Radioactivity Monitors 0 1(2) RE0020 0 1(2) REO021 0 1(2) RE0848 G 1(2) RE0018*The blowdown gump is common to both units.Figure 2-3. Liquid Radwaste Discharge Pathways 2-16 VER 29 VEGP ODCM 2.3 LIQUID EFFLUENT MONITOR SETPOINTS 2.3.1 General Provisions Regarding Setpoints Liquid monitor setpoints calculated in accordance with the methodology presented in this section will be regarded as upper bounds for the actual high alarm setpoints. That is, a lower value for the high alarm setpoint may be established or retained on the monitor, if desired. Intermediate level setpoints should be established at an appropriate level to give sufficient warning prior to reaching the high alarm setpoint. If no release is planned for a particular pathway, or if there is no detectable activity in the planned release, the monitor setpoint should be established as close to background as practical to prevent spurious alarms, and yet alarm should an inadvertent release occur.Two basic setpoint methodologies are presented below. For radwaste system discharge monitors, setpoints are determined to assure that the limits of Section 2.1.2 are not exceeded. For monitors on streams that are not expected to contain significant radioactivity, the purpose of the monitor setpoints is to cause an alarm on low levels of radioactivity, and to terminate the release where this is possible. Section 2.1.1 establishes the requirements for liquid effluent monitoring instrumentation. Table 2-4 lists the monitors for which each of the setpoint methodologies is applicable. 2-17 VER 29 VEGP ODCM Table 2-4. Applicability of Liquid Monitor Setpoint Methodologies Liquid Radwaste Discharge Monitors Setpoint Method: Section 2.3.2 Release Type: BATCH Unit I or Unit 2 Liquid Waste Treatment System Effluent Monitor: 1RE-0018 / 2RE-0018 Normally Low-Radioactivity Streams with Termination or Diversion upon Alarm Setpoint Method: Section 2.3.3 Release Type: CONTINUOUS Unit 1 or Unit 2 Steam Generator Blowdown Effluent Monitor: 1 RE-0021 / 2RE-0021 Unit 1 or Unit 2 Turbine Building Drain Effluent Monitor: 1 RE-0848 / 2RE-0848 Normally Low-Radioactivity Streams with Alarm Only Setpoint Method: Section 2.3.3 Release Type: CONTINUOUS Unit 1 or Unit 2 Nuclear Service Cooling Water System Effluent Monitors (2 per unit): 1RE-0020 A and B 2RE-0020 A and B 2-18 VER 29 VEGP ODCM 2.3.2 Setpoints for Radwaste System Discharge Monitors 2.3.2.1 Overview of Method LIQUID RADWASTE TREATMENT SYSTEM effluent line radioactivity monitors are intended to provide alarm and automatic termination of release prior to exceeding the limits specified in Section 2.1.2 at the point of release of the diluted effluent into the UNRESTRICTED AREA. Therefore, their alarm/trip setpoints are established to ensure compliance with the following equation (equation adapted from Addendum to Reference 1): c'f- <- TF" CECL (2.1)F+f where: CECL = the Effluent Concentration Limit corresponding to the mix of radionuclides in the effluent being considered for discharge, in g.Ci/mL.c = the setpoint, in jgCi/mL, of the radioactivity monitor measuring the concentration of radioactivity in the effluent line prior to dilution and subsequent release. The setpoint represents a concentration which, if exceeded, could result in concentrations exceeding the limits of Section 2.1.2 in the UNRESTRICTED AREA.f = the effluent flowrate at the location of the radioactivity monitor, in gpm.F = the dilution stream flowrate which can be assured prior to the release point to the UNRESTRICTED AREA, in gpm. A predetermined dilution flowrate must be assured for use in the calculation of the radioactivity monitor setpoint.TF = the tolerance factor selected to allow flexibility in the establishment of a practical monitor setpoint which could accommodate effluent releases at concentrations higher than the ECL values stated in 10 CFR 20, Appendix B, Table 2, Column 2; the tolerance factor must not exceed a value of 10.While equation (2.1) shows the relationships of the critical parameters that determine the setpoint, it cannot be applied practically to a mixture of radionuclides with different Effluent Concentration Limits (ECLs). For a mixture of radionuclides, equation (2.1) is satisfied in a practicable manner based on the calculated ECL fraction of the radionuclide mixture and the dilution stream flowrate that can be assured for the 2-19 VER 29 VEGP ODCM duration of the release (Fd), by calculating the maximum permissible effluent flowrate (fin) and the radioactivity monitor setpoint (c).The setpoint method presented below is applicable to the release of only one tank of liquid radwaste per reactor unit at a given time. Liquid releases must be controlled administratively to ensure that this condition is met; otherwise, the setpoint method may not ensure that the limits of Section 2.1.2 are not exceeded.2.3.2.2 Setpoint Calculation Steps Step 1: Determine the radionuclide concentrations in the liquid waste being considered for release in accordance with the sampling and analysis requirements of Section 2.1.2.All liquid radwastes treated by the LIQUID RADWASTE TREATMENT SYSTEM are collected in waste monitor tanks for sampling and analysis. The 5,000-gallon waste monitor tanks are recirculated for a minimum of 30 minutes, and the 20,000-gallon waste monitor tanks are recirculated for a minimum of 45 minutes. This mixing assures that a representative sample can be taken from the tank.The total concentration of the liquid waste is determined by the results of all required analyses on the collected sample, as follows: YZCi = C + ZC +Cf + + c + YICg (2.2)s g where: C, = the gross concentration of alpha emitters in the liquid waste, not less than that measured in the most recent applicable composite sample.Cs = the concentration of strontium radioisotope s (Sr-89 or Sr-90) in the liquid waste, not less than that measured in the most recent applicable composite sample.Cf = the concentration of Fe-55 in the liquid waste, not less than that measured in the most recent applicable composite sample.Ct = the concentration of H-3 in the liquid waste, not less than that measured in the most recent applicable composite sample.Cg = the concentration of gamma emitter g in the liquid waste as measured by gamma ray spectroscopy performed on the sample for the release under consideration. The Cg term will be included in the analysis of each waste sample; terms for gross concentrations of alpha emitters, Sr-89, Sr-90, Fe-55, and tritium will be included in 2-20 VER 29 VEGP ODCM accordance with the sampling and analysis program required for the waste stream (see Section 2.1.2). For each analysis, only radionuclides identified and detected above background for the given measurement should be included in the calculation. When using the alternate setpoint methodology of step 5.b, the historical maximum values of Ca, Cs, Cf, and Ct shall be used.Step 2: Determine the required dilution factor for the mix of radionuclides detected in the waste.Measured radionuclide concentrations are used to calculate ECL fractions. The ECL fractions are used along with a safety factor to calculate the required dilution factor; this is the minimum ratio of dilution flowrate to waste flowrate that must be maintained throughout the release to ensure that the limits of Section 2.1.2 are not exceeded at the point of discharge into the UNRESTRICTED AREA. The required dilution factor, RDF, is calculated as the sum of the dilution factors required for gamma emitters (RDFy) and for non-gamma-emitters (RDFny): RDF = YCL+ [(SF)(TF)I (2.3)= RDFY + RDF,,y RDF), = (sFCr) (2.4)(SFXTF)where: SC" Cf C,'C+ + +RDF,,, = ECL, ECL,. ECL ECL,j (2.5)(SF)(TF )C = the measured concentration of radionuclide i as defined in step 1, in J4Ci/mL. The Ca, Cs, Cf, and Ct terms will be included in the calculation as appropriate. ECL = the Effluent Concentration Limit for radionuclide i from 10 CFR Part 20, Appendix B, Table 2, Column 2 (except for noble gases as discussed below). In the absence of information regarding the solubility classification of a given radionuclide in the waste stream, the solubility class with the lowest ECL shall be assumed. For dissolved or entrained noble gases, the concentration shall be limited to 1x10- ptCi/mL. For gross alpha, the ECL shall be 2x1 0-9 tCi/mL; if specific alpha-emitting radionuclides are measured, the ECL for the specific radionuclide(s) should be used.2-21 VER 29 VEGP ODCM SF = the safety factor selected to compensate for statistical fluctuations and errors of measurement. The value for the safety factor must be between 0 and 1. A value of 0.5 is reasonable for liquid releases; a more precise value may be developed if desired.TF = the tolerance factor (as defined in Section 2.3.2.1).Step 3: Determine the release-specific assured dilution stream flowrate.Determine the dilution stream flowrate that can be assured during the release period, designated Fd; this value is the setpoint for the dilution stream flowrate measurement device.If simultaneous radioactive releases are planned from the same or different reactor units, the dilution stream must be allocated among all the simultaneous releases. There will only be one such release per unit at a given time, unless there is detectable radioactivity in one of the normally low-radioactivity streams (see Section 2.3.3).Allocation of the dilution stream to multiple release paths is accomplished as follows: F:O, = Fd (AFP) (2.6)where: Fdp = the dilution flowrate allocated to release pathway p, in gpm.AFp = the dilution allocation factor for release pathway p. AFn may be assigned any value between 0 and 1 for each active release pathway, under the condition that the sum of the AFp for all active release pathways for the entire plant site does not exceed 1.Fd = the assured minimum dilution flow for the unit, in gpm.In the normal case in which the only release pathways with detectable radioactivity are the LIQUID RADWASTE TREATMENT SYSTEMs of each unit, AFp for each unit may be assigned the value of 0.5 to permit releases from either unit to be made without regard to any releases from the other unit; if only one unit's LIQUID RADWASTE TREATMENT SYSTEM is releasing at a given time, its AFp may be increased proportionately. If more precise allocation factor values are desired, they may be determined based on the relative radiological impact of each active release pathway;this may be approximated by multiplying the RDF of each effluent stream by its respective planned release flowrate, and comparing these values. If only one simultaneous release is being made, its AFp may be assigned the value of 1, making Fdp equal to Fd.2-22 VER 29 VEGP ODCM For the case where RDF < 1, the planned release meets the limits of Section 2.1.2 without dilution, and could be released with any desired effluent flowrate and dilution flowrate. However, in order to maintain individual doses due to liquid effluent releases as low as is reasonably achievable, no releases with detectable radioactivity should be made if the assured dilution flowrate, Fd, is less than 12,000 gpm.Step 4: Determine the maximum allowable waste discharge flowrate.For the case where RDF > 1, the maximum permissible effluent discharge flowrate for this release pathway, fm.p (in gpm), is calculated as follows: Fd° (2.7)P (RDF- 1)For the case RDF _< 1, equation (2.7) is not valid. However, as discussed above, when RDF < 1, the release may be made at full discharge pump capacity; the radioactivity monitor setpoint must still be calculated in accordance with Step 5 below.NOTE 1: Discharge flowrates are actually limited by the discharge pump capacity.When the calculated maximum permissible release flowrate exceeds the pump capacity, the release may be made at full capacity. Discharge flowrates less than the pump capacity must be achieved by throttling if this is available; if throttling is not available, the release may not be made as planned.NOTE 2: If, at the time of the planned release, there is detectable radioactivity due to plant operations in the dilution stream, the diluting capacity of the dilution stream is diminished. (In addition, sampling and analysis of the other radioactive effluents affecting the dilution stream must be sufficient to ensure that the liquid effluent dose limits specified in the controls of Section 2.1.3 are not exceeded.) Under these conditions, equation (2.7)must be modified to account for the radioactivity present in the dilution stream prior to the introduction of the planned release: fp =(RDF- 1) r dF ,ECLJ(2.8) where: Cir the measured concentration of radionuclide i in release pathway r that is contributing to radioactivity in the dilution stream.fr = the effluent discharge flowrate of release pathway r.If the entire dilution stream contains detectable activity due to plant operations, whether or not its source is identified, fr = Fd, and Cir is the 2-23 VER 29 VEGP ODCM concentration in the total dilution system. This note does not apply: a) if the RDF of the planned release is _< 1; or b) if the release contributing radioactivity to the dilution stream has been accounted for by the assignment of an allocation factor.Step 5: Determine the maximum radioactivity monitor setpoint concentration. Based on the values determined in previous steps, the radioactivity monitor setpoint for the planned release is calculated to ensure that the limits of Section 2.1.2 will not be exceeded. Because the radioactivity monitor responds primarily to gamma radiation, the monitor setpoint cp for release pathway p (in [tCi/mL) is based on the concentration of gamma emitters in the waste stream, as follows: cP = AP Cg (2.9)where: Ap an adjustment factor which will allow the setpoint to be established in a practical manner to prevent spurious alarms while allowing a margin between measured concentrations and the limits of Section 2.1.2.Step 5.a. If the concentration of gamma emitters in the effluent to be released is sufficient that the high alarm setpoint can be established at a level that will prevent spurious alarms, Ap should be calculated as follows: 1 Ap = x ADF RDF (2.10)1- (F,1P + f,,P)RDF Alp where: ADF = the assured dilution factor.fap the anticipated actual discharge flowrate for the planned release (in gpm), a value less than fmp.The release must then be controlled so that the actual effluent discharge flowrate does not exceed fap at any time.Step 5.b. Alternatively, Ap may be calculated as follows: ADF- RDF,,n AP =RDFy (2.11)2-24 VER 29 VEGP ODCM Step 5.c. Evaluate the computed value of Ap as follows: If Ap > 1, calculate the monitor setpoint, cp. However, if cp is within about 10 percent of Cg, it may be impractical to use this value of cp.This situation indicates that measured concentrations are approaching values which would cause limits of Section 2.1.2 to be exceeded. Therefore, steps should be taken to reduce potential concentrations at the point of discharge; these steps may include decreasing the planned effluent discharge flowrate, increasing the dilution stream flowrate, postponing simultaneous releases, and/or decreasing the effluent concentrations by further processing the liquid planned for release. Alternatively, allocation factors for the active liquid release pathways may be reassigned. When one or more of these actions has been taken, repeat Steps 1-5 to calculate a new radioactivity monitor setpoint.If Ap < 1, the release may not be made as planned. Consider the alternatives discussed in the paragraph above, and calculate a new setpoint based on the results of the actions taken.2.3.2.3 Use of the Calculated Setpoint The setpoint calculated above is in the units jtCi/mL. The monitor actually measures a count rate, subtracts a predetermined background count rate, and multiplies by a calibration factor to convert from count rate to [tCi/mL.Initial calibration of the monitors by the manufacturer and Georgia Power Company utilized NIST-traceable liquid solutions with gamma ray emissions over the range 0.08 to 1.33 MeV, in the exact geometry of each production monitor. The calibration factor is a function of the radionuclide mix in the liquid to be released, and will be calculated for the monitor based on the results of the pre-release sample results from the laboratory gamma-ray spectrometer system. The mix-dependent calibration factor will be used as the gain factor in the PERMS monitor, or used to modify the calculated base monitor setpoint so that the default calibration factor in the PERMS monitor can be left unchanged. Notwithstanding the initial calibration, monitor calibration data for conversion between count rate and concentration may include operational data obtained from determining the monitor response to stream concentrations measured by liquid sample analysis. In all cases, monitor background must be controlled so that the monitor is capable of responding to concentrations in the range of the setpoint value.2-25 VER 29 VEGP ODCM 2.3.3 Setpoints for Monitors on Normally Low-Radioactivity Streams Radioactivity in these streams (listed in Table 2-4 above) is expected to be at very low levels, generally below detection limits. Accordingly, the purpose of these monitors is to alarm upon the occurrence of significant radioactivity in these streams, and to terminate or divert the release where this is possible.2.3.3.1 Normal Conditions When radioactivity in one of these streams is at its normal low level, its radioactivity monitor setpoint should be established as close to background as practical to prevent spurious alarms, and yet alarm should an inadvertent release occur.2.3.3.2 Conditions Requiring an Elevated Setpoint Under the following conditions, radionuclide concentrations must be determined and an elevated radioactivity monitor setpoint determined for these pathways: For streams that can be diverted or isolated, a new monitor setpoint must be established when it is desired to discharge the stream directly to the dilution water even though the radioactivity in the stream exceeds the level which would normally be diverted or isolated.* For streams that cannot be diverted or isolated, a new monitor setpoint must be established whenever: the radioactivity in the stream becomes detectable above the background levels of the applicable laboratory analyses; or the associated radioactivity monitor detects activity in the stream at levels above the established alarm setpoint.When an elevated monitor setpoint is required for any of these effluent streams, it should be determined in the same manner as described in Section 2.3.2. However, special consideration must be given to Step 3. An allocation factor must be assigned to the normally low-radioactivity release pathway under consideration, and allocation factors for other release pathways discharging simultaneously must be adjusted downward (if necessary) to ensure that the sum of the allocation factors does not exceed 1. Sampling and analysis of the normally low-radioactivity streams must be sufficient to ensure that the liquid effluent dose limits specified in the controls of Section 2.1.3 are not exceeded.2-26 VER 29 VEGP ODCM 2.4 LIQUID EFFLUENT DOSE CALCULATIONS The following sub-sections present the methods required for liquid effluent dose calculations, in deepening levels of detail. Applicable site-specific pathways and parameter values for the calculation of De, A 1 j, and CFiv are summarized in Table 2-5.2.4.1 Calculation of Dose The dose limits for a MEMBER OF THE PUBLIC specified in Section 2.1.3 are on a per-unit basis. Therefore, the doses calculated in accordance with this section must be determined and recorded on a per-unit basis, including apportionment of releases shared between the two units.For the purpose of implementing Section 2.1.3, the dose to the maximum exposed individual due to radionuclides identified in liquid effluents released from each unit to UNRESTRICTED AREAS will be calculated as follows (equation from Reference 1, page 15): D,=Z rI ('At, CiF,) (2.12)where: D, = the cumulative dose commitment to the total body or to any organ T, in mrem, due to radioactivity in liquid effluents released during the total of the m time periods At,.Aj, = the site-related adult ingestion dose commitment factor, for the total body or for any organ T, due to identified radionuclide i, in (mrem.mL)/(h.plCi). Methods for the calculation of A, are presented below in Section 2.4.2.The values of Aj, to be used in dose calculations for releases from the plant site are listed in Table 2-8.At, = the length of time period I, over which C,/ and F, are averaged for liquid releases, in h.Ci, = the average concentration of radionuclide i in undiluted liquid effluent during time period I, in [tCi/mL. Only radionuclides identified and detected above background in their respective samples should be included in the calculation. F, = the near-field average dilution factor in the receiving water of the UNRESTRICTED AREA: 2-27 VER 29 VEGP ODCM F, f (2.13)F, xZ where: ft = the average undiluted liquid waste flowrate actually observed during the period of radioactivity release, in gpm.Ft = the average dilution stream flowrate actually observed during the period of radioactivity release, in gpm. If simultaneous releases from both units occur, the dilution stream flowrate Ft must be allocated between them. In such cases, F, is unit-specific. Z = the applicable dilution factor for the receiving water body, in the near field of the discharge structure, during the period of radioactivity release, from Table 2-5.NOTE: In equation (2.13), the product (Ft x Z) is limited to 1000 cfs (= 448,000 gpm) or less. (Reference 1, Section 4.3.)2.4.2 Calculation of A, The site-related adult ingestion dose commitment factor, Aij, is calculated as follows (equation adapted from Reference 1, page 16, by addition of the irrigated garden vegetation pathway): ,= 1. 14x 1' U+fBFi e-,'s + U,,CF., DF., (2.14)where: 1.14 x 10 5 = a units conversion factor, determined by: 106 pCi/pCi x 10 3 mL/L + 8760 h/y.U= the adult drinking water consumption rate applicable to the plant site (L/y).Dw= the dilution factor from the near field of the discharge structure for the plant site to the potable water intake location.= the decay constant for radionuclide i (h-1). Values of ki used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.tw= the transit time from release to receptor for potable water 2-28 VER 29 VEGP ODCM consumption (h).Uf = the adult rate of fish consumption applicable to the plant site (kg/y).BFj = the bioaccumulation factor for radionuclide i applicable to freshwater fish in the receiving water body for the plant site, in (pCi/kg)/(pCi/L) = (L/kg). For specific values applicable to the plant site, see Table 2-6.tf = the transit time from release to receptor for fish consumption (h).U= the adult consumption rate for irrigated garden vegetation applicable to the plant site (kg/y).CFiv = the concentration factor for radionuclide i in irrigated garden vegetation, as applicable to the vicinity of the plant site, in (pCi/kg)/(pCi/L). Methods for calculation of CFiv are presented below in Section 2.4.3.DFi, = the dose conversion factor for radionuclide i for adults, in organ T (mrem/pCi). For specific values, see Table 2-7.2.4.3 Calculation of Cfiv The concentration factor for radionuclide i in irrigated garden vegetation, CFiv in (L/kg), is calculated as follows: For radionuclides other than tritium (equation adapted from Reference 3, equations A-8 and A-9): iv=M fJ (2.15)For tritium (equation adapted from Reference 3, equations A-9 and A-10): CFjv = M. L, (2.16)where: M = the additional river dilution factor from the near field of the discharge structure for the plant site to the point of irrigation water usage.= the average irrigation rate during the growing season (L)/(m 2.h).r = the fraction of irrigation-deposited activity retained on the edible portions 2-29 VER 29 VEGP ODCM of leafy garden vegetation. Y, = the areal density (agricultural productivity) of leafy garden vegetation (kg/Mr 2)f, = the fraction of the year that garden vegetation is irrigated. B 1 v = the crop to soil concentration factor applicable to radionuclide i (pCi/kg garden vegetation)/(pCi/kg soil).P = the effective surface density of soil (kg/m 2).ki = the decay constant for radionuclide i (h-1). Values of k, used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.Xw = the rate constant for removal of activity from plant leaves by weathering (h-1).XEi = the effective removal rate for activity deposited on crop leaves (h-1)calculated as: XEi = Xi + Xw.te = the period of leafy garden vegetation exposure during the growing season (h).tb = the period of long-term buildup of activity in soil (h).th = the time between harvest of garden vegetation and human consumption (h).Lv = the water content of leafy garden vegetation edible parts (Llkg).2-30 VER 29 VEGP ODCM Table 2-5.Parameters for Calculation of Doses Due to Liquid Effluent Releases Dose Calculation Receptor Locations: Fish: Vicinity of plant discharge Drinking Water: 112 miles downstream, at Beaufort, SC (Reference 12)Irrigated Garden Vegetation: None (Reference 12)Numerical Parameters: Parameter Value Reference Z Uw Dw tw Uf tf Uv M I r Yv f, P xw t.tb th L, 10, for May through December 20, for January through April 730 L/y 8 48 h 21 kg/y 24 h 0 kg/y 1.0+No value 0.25 2.0 kg/m 2 1.0+240 kg/m 2 0.0021 h-1 (i.e., half-life of 14 d)1440 h (= 60 d)1.31 x 10 5 h (= 15 y)24 h 0.92 L/kg Ref. 11 Ref 3 Ref. 7 Ref. 3, Sec. A.2; Ref. 8 Ref. 3, Table E-5 Ref. 3, Sec. A.2 Ref. 12 Ref. 3, Table E-15.Ref. 3, Table E-1 5 Ref. 3, Table E-15 Ref. 3, Table E-15 Ref. 3, Table E-15 Ref. 3, Table E-15 Ref. 3, Table E-15 Based on Ref. 21, Table 5.16 (for lettuce, cabbage, etc.)* -Because there is no irrigated garden vegetation pathway downstream of the plant site, the consumption of irrigated garden vegetation is set to zero, and the other pathway parameters are defaults.+ -There is no established default value for this parameter. The most conservative physically realistic value is 1.0.2-31 VER 29 VEGP ODCM Table 2-6.Element Transfer Factors Freshwater Fish Element BFj*H 9.0 E-01 C 4.6 E+03 Na 1.0 E+02 P 3.0 E+03 Cr 2.0 E+02 Mn 4.0 E+02 Fe 1.0 E+02 Co 5.0 E+01 Ni 1.0 E+02 Cu 5.0 E+01 Zn 2.0 E+03 Br 4.2 E+02 Rb 2.0 E+03 Sr 3.0 E+01 Y 2.5 E+01 Zr 3.3 E+00 Nb 5.5 E+02 Mo 1.0 E+01 Tc 1.5 E+01 Ru 1.0 E+01 Rh 1.0 E+01 Ag 2.3 E+00 Sb 2.0 E+02 Te 4.0 E+02 I 1.5 E+01 Cs 2.0 E+03 Ba 4.0 E+00 La 2.5 E+01 Ce 1.0 E+00 Pr 2.5 E+01 Nd 2.5 E+01 W 1.2 E+03 Np 1.0 E+01 Bioaccumulation Factors for freshwater fish, in (pCi/kg)/(pCi/L). They are obtained from Reference 3 (Table A-I), except as follows: Reference 9 for P; Reference 2 (Table A-8)for Ag; and Reference 10 for Nb and Sb.2-32 VER 29 VEGP ODCM Table 2-7. Adult Ingestion Dose Factors Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 No Data 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 C-14 2.84E-06 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 Na-24 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 P-32 1.93E-04 1.20E-05 7.46E-06 No Data No Data No Data 2.17E-05 Cr-51 No Data No Data 2.66E-09 1.59E-09 5.86E-10 3.53E-09 6.69E-07 Mn-54 No Data 4.57E-06 8.72E-07 No Data 1.36E-06 No Data 1.40E-05 Mn-56 No Data 1.15E-07 2.04E-08 No Data 1.46E-07 No Data 3.67E-06 Fe-55 2.75E-06 1.90E-06 4.43E-07 No Data No Data 1.06E-06 1.09E-06 Fe-59 4.34E-06 1.02E-05 3.91E-06 No Data No Data 2.85E-06 3.40E-05 Co-58 No Data 7.45E-07 1.67E-06 No Data No Data No Data 1.51E-05 Co-60 No Data 2.14E-06 4.72E-06 No Data No Data No Data 4.02E-05 Ni-63 1.30E-04 9.01E-06 4.36E-06 No Data No Data No Data 1.88E-06 Ni-65 5.28E-07 6.86E-08 3.13E-08 No Data No Data No Data 1.74E-06 Cu-64 No Data 8.33E-08 3.91E-08 No Data 2.1OE-07 No Data 7.1OE-06 Zn-65 4.84E-06 1.54E-05 6.96E-06 No Data 1.03E-05 No Data 9.70E-06 Zn-69 1.03E-08 1.97E-08 1.37E-09 No Data 1.28E-08 No Data 2.96E-09 Br-83 No Data No Data 4.02E-08 No Data No Data No Data 5.79E-08 Br-84 No Data No Data 5.21E-08 No Data No Data No Data 4.09E-13 Br-85 No Data No Data 2.14E-09 No Data No Data No Data No Data Rb-86 No Data 2.11E-05 9.83E-06 No Data No Data No Data 4.16E-06 Rb-88 No Data 6.05E-08 3.21E-08 No Data No Data No Data 8.36E-19 Rb-89 No Data 4.01E-08 2.82E-08 No Data No Data No Data 2.33E-21 Sr-89 3.08E-04 No Data 8.84E-06 No Data No Data No Data 4.94E-05 Sr-90 7.58E-03 No Data 1.86E-03 No Data No Data No Data 2.19E-04 Sr-91 5.67E-06 No Data 2.29E-07 No Data No Data No Data 2.70E-05 All values are in (mrem/pCi ingested). They are obtained from Reference 3 (Table E-1 1), except as follows: Reference 2 (Table A-3) for Rh-105, Sb-124, and Sb-125.2-33 VER 29 VEGP ODCM Table 2-7 (contd). Adult Ingestion Dose Factors Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 2.15E-06 No Data 9.30E-08 No Data No Data No Data 4.26E-05 Y-90 9.62E-09 No Data 2.58E-10 No Data No Data No Data 1.02E-04 Y-91m 9.09E-11 No Data 3.52E-12 No Data No Data No Data 2.67E-10 Y-91 1.41E-07 No Data 3.77E-09 No Data No Data No Data 7.76E-05 Y-92 8.45E-10 No Data 2.47E-11 No Data No Data No Data 1.48E-05 Y-93 2.68E-09 No Data 7.40E-1 1 No Data No Data No Data 8.50E-05 Zr-95 3.04E-08 9.75E-09 6.60E-09 No Data 1.53E-08 No Data 3.09E-05 Zr-97 1.68E-09 3.39E-10 1.55E-10 No Data 5.12E-10 No Data 1.05E-04 Nb-95 6.22E-09 3.46E-09 1.86E-09 No Data 3.42E-09 No Data 2.1OE-05 Mo-99 No Data 4.31E-06 8.20E-07 No Data 9.76E-06 No Data 9.99E-06 Tc-99m 2.47E-10 6.98E-10 8.89E-09 No Data 1.06E-08 3.42E-10 4.13E-07 Tc-101 2.54E-10 3.66E-10 3.59E-09 No Data 6.59E-09 1.87E-10 1.1OE-21 Ru-103 1.85E-07 No Data 7.97E-08 No Data 7.06E-07 No Data 2.16E-05 Ru-105 1.54E-08 No Data 6.08E-09 No Data 1.99E-07 No Data 9.42E-06 Ru-106 2.75E-06 No Data 3.48E-07 No Data 5.31 E-06 No Data 1.78E-04 Rh-105 1.22E-07 8.86E-08 5.83E-08 No Data 3.76E-07 No Data 1.41 E-05 Ag-110m 1.60E-07 1.48E-07 8.79E-08 No Data 2.91 E-07 No Data 6.04E-05 Sb-124 2.81E-06 5.30E-08 1.11E-06 6.79E-09 No Data 2.18E-06 7.95E-05 Sb-125 2.23E-06 2.40E-08 4.48E-07 1.98E-09 No Data 2.33E-04 1.97E-05 Te-125m 2.68E-06 9.71E-07 3.59E-07 8.06E-07 1.09E-05 No Data 1.07E-05 Te-127m 6.77E-06 2.42E-06 8.25E-07 1.73E-06 2.75E-05 No Data 2.27E-05 Te-127 1.1OE-07 3.95E-08 2.38E-08 8.15E-08 4.48E-07 No Data 8.68E-06 Te-129m 1.15E-05 4.29E-06 1.82E-06 3.95E-06 4.80E-05 No Data 5.79E-05 Te-129 3.14E-08 1.18E-08 7.65E-09 2.41E-08 1.32E-07 No Data 2.37E-08 Te-131m 1.73E-06 8.46E-07 7.05E-07 1.34E-06 8.57E-06 No Data 8.40E-05 Te-131 1.97E-08 8.23E-09 6.22E-09 1.62E-08 8.63E-08 No Data 2.79E-09 2-34 VER 29 VEGP ODCM Table 2-7 (contd). Adult Ingestion Dose Factors Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 2.52E-06 1.63E-06 1.53E-06 1.80E-06 1.57E-05 No Data 7.71E-05 1-130 7.56E-07 2.23E-06 8.80E-07 1.89E-04 3.48E-06 No Data 1.92E-06 1-131 4.16E-06 5.95E-06 3.41E-06 1.95E-03 1.02E-05 No Data 1.57E-06 1-132 2.03E-07 5.43E-07 1.90E-07 1.90E-05 8.65E-07 No Data 1.02E-07 1-133 1.42E-06 2.47E-06 7.53E-07 3.63E-04 4.31E-06 No Data 2.22E-06 1-134 1.06E-07 2.88E-07 1.03E-07 4.99E-06 4.58E-07 No Data 2.51E-10 1-135 4.43E-07 1.16E-06 4.28E-07 7.65E-05 1.86E-06 No Data 1.31E-06 Cs-134 6.22E-05 1.48E-04 1.21E-04 No Data 4.79E-05 1.59E-05 2.59E-06 Cs-136 6.51E-06 2.57E-05 1.85E-05 No Data 1.43E-05 1.96E-06 2.92E-06 Cs-137 7.97E-05 1.09E-04 7.14E-05 No Data 3.70E-05 1.23E-05 2.11E-06 Cs-138 5.52E-08 1.09E-07 5.40E-08 No Data 8.01E-08 7.91E-09 4.65E-13 Ba-139 9.70E-08 6.91E-11 2.84E-09 No Data 6.46E-11 3.92E-11 1.72E-07 Ba-140 2.03E-05 2.55E-08 1.33E-06 No Data 8.67E-09 1.46E-08 4.18E-05 Ba-141 4.71E-08 3.56E-11 1.59E-09 No Data 3.31E-11 2.02E-11 2.22E-17 Ba-142 2.13E-08 2.19E-11 1.34E-09 No Data 1.85E-11 1.24E-11 3.OOE-26 La-140 2.50E-09 1.26E-09 3.33E-10 No Data No Data No Data 9.25E-05 La-142 1.28E-10 5.82E-11 1.45E-11 No Data No Data No Data 4.25E-07 Ce-141 9.36E-09 6.33E-09 7.18E-10 No Data 2.94E-09 No Data 2.42E-05 Ce-143 1.65E-09 1.22E-06 1.35E-10 No Data 5.37E-10 No Data 4.56E-05 Ce-144 4.88E-07 2.04E-07 2.62E-08 No Data 1.21E-07 No Data 1.65E-04 Pr-143 9.20E-09 3.69E-09 4.56E-10 No Data 2.13E-09 No Data 4.03E-05 Pr-144 3.01E-11 1.25E-11 1.53E-12 No Data 7.05E-12 No Data 4.33E-18 Nd-147 6.29E-09 7.27E-09 4.35E-10 No Data 4.25E-09 No Data 3.49E-05 W-187 1.03E-07 8.61E-08 3.01E-08 No Data No Data No Data 2.82E-05 Np-239 1.19E-09 1.17E-10 6.45E-11 No Data 3.65E-10 No Data 2.40E-05 2-35 VER 29 VEGP ODCM Table 2-8. Site-Related Ingestion Dose Factors, A 1.Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 0.00 1.32E+00 1.32E+00 1.32E+00 1.32E+00 1.32E+00 1.32E+00 C-14 3.13E+04 6.26E+03 6.26E+03 6.26E+03 6.26E+03 6.26E+03 6.26E+03 Na-24 1.36E+02 1.36E+02 1.36E+02 1.36E+02 1.36E+02 1.36E+02 1.36E+02 P-32 1.32E+06 8.22E+04 5.11E+04 0.00 0.00 0.00 1.49E+05 Cr-51 0.00 0.00 1.27E+00 7.58E-01 2.79E-01 1.68E+00 3.19E+02 Mn-54 0.00 4.41E+03 8.42E+02 0.00 1.31E+03 0.00 1.35E+04 Mn-56 0.00 1.74E-01 3.08E-02 0.00 2.21E-01 0.00 5.55E+00 Fe-55 6.86E+02 4.74E+02 1.11E+02 0.00 0.00 2.65E+02 2.72E+02 Fe-59 1.07E+03 2.51E+03 9.61E+02 0.00 0.00 7.01E+02 8.36E+03 Co-58 0.00 9.59E+01 2.15E+02 0.00 0.00 0.00 1.94E+03 Co-60 0.00 2.78E+02 6.14E+02 0.00 0.00 0.00 5.23E+03 Ni-63 3.25E+04 2.25E+03 1.09E+03 0.00 0.00 0.00 4.70E+02 Ni-65 1.72E-01 2.23E-02 1.02E-02 0.00 0.00 0.00 5.66E-01 Cu-64 0.00 2.75E+00 1.29E+00 0.00 6.94E+00 0.00 2.35E+02 Zn-65 2.32E+04, 7.37E+04 3.33E+04 0.00 4.93E+04 0.00 4.64E+04 Zn-69 7.88E-07 1.51E-06 1.05E-07 0.00 9.79E-07 0.00 2.26E-07 Br-83 0.00 0.00 3.83E-02 0.00 0.00 0.00 5.52E-02 Br-84 0.00 0.00 1.22E-12 0.00 0.00 0.00 9.61E-18 Br-85 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Rb-86 0.00 9.75E+04 4.54E+04 0.00 0.00 0.00 1.92E+04 Rb-88 0.00 1.29E-22 6.82E-23 0.00 0.00 0.00 1.78E-33 Rb-89 0.00 1.61E-26 1.14E-26 0.00 0.00 0.00 0.00 Sr-89 2.49E+04 0.00 7.16E+02 0.00 0.00 0.00 4.OOE+03 Sr-90 6.23E+05 0.00 1.53E+05 0.00 0.00 0.00 1.80E+04 Sr-91 7.25E+01 0.00 2.93E+00 0.00 0.00 0.00 3.45E+02 Sr-92 3.33E-01 0.00 1.44E-02 0.00 0.00 0.00 6.60E+00 Y-90 5.04E-01 0.00 1.35E-02 0.00 0.00 0.00 5.34E+03 Y-91m 1.04E-11 0.00 4.01E-13 0.00 0.00 0.00 3.04E-11 Y-91 9.77E+00 0.00 2.61E-01 0.00 0.00 0.00 5.38E+03 Y-92 4.61E-04 0.00 1.35E-05 0.00 0.00 0.00 8.07E+00 Y-93 3.19E-02 0.00 8.82E-04 0.00 0.00 0.00 1.01E+03 Zr-95 5.47E-01 1.75E-01 1.19E-01 0.00 2.75E-01 0.00 5.56E+02 Zr-97 7.40E-03, 1.49E-03 6.83E-04 0.00 2.26E-03 0.00 4.62E+02 Nb-95 8.09E+00 4.50E+00 2.42E+00 0.00 4.45E+00 0.00 2.73E+04 Mo-99 0.00 1.07E+02 2.04E+01 0.00 2.43E+02 0.00 2.49E+02 Tc-99m 5.70E-04 1.61E-03 2.05E-02 0.00 2.44E-02 7.89E-04 9.53E-01 All values are in (mrem.mL)/(h.[tCi). They are calculated using equation (2.14), and data from Table 2-5, Table 2-6, and Table 2-7. When "No Data" is shown for a radionuclide-organ combination in Table 2-7, A 1 , factors in this table are presented as zero.2-36 VER 29 VEGP ODCM Table 2-8 (contd). Site-Related Ingestion Dose Factors, Aj, Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI Tc-101 2.71E-33 3.91E-33 3.83E-32 0.00 7.03E-32 2.00E-33 0.00 Ru-103 6.21E+00 0.00 2.68E+00 0.00 2.37E+01 0.00 7.25E+02 Ru-105 8.79E-03 0.00 3.47E-03 0.00 1.14E-01 0.00 5.38E+00 Ru-106 9.42E+01 0.00 1.19E+01 0.00 1.82E+02 0.00 6.1OE+03 Rh-105 2.32E+00 1.69E+00 1.11E+00 0.00 7.15E+00 0.00 2.68E+02 Ag-110m 2.53E+00 2.34E+00 1.39E+00 0.00 4.61E+00 0.00 9.56E+02 Sb-124 1.36E+03 2.56E+01 5.37E+02 3.28E+00 0.00 1.05E+03 3.84E+04 Sb-125 1.09E+03 1.17E+01 2.19E+02 9.68E-01 0.00 1.14E+05 9.63E+03 Te-125m 2.56E+03 9.29E+02 3.43E+02 7.71E+02 1.04E+04 0.00 1.02E+04 Te-127m 6.51E+03 2.33E+03 7.93E+02 1.66E+03 2.64E+04 0.00 2.18E+04 Te-127 1.78E+01 6.40E+00 3.85E+00 1.32E+01 7.25E+01 0.00 1.41E+03 Te-129m 1.09E+04 4.07E+03 1.73E+03 3.74E+03 4.55E+04 0.00 5.49E+04 Te-129 1.78E-05 6.68E-06 4.33E-06 1.36E-05 7.47E-05 0.00 1.34E-05 Te-131m 9.57E+02 4.68E+02 3.90E+02 7.42E+02 4.74E+03 0.00 4.65E+04 Te-131 8.64E-17 3.61E-17 2.73E-17 7.10E-17 3.78E-16 0.00 1.22E-17 Te-132 1.97E+03 1.27E+03 1.19E+03 1.41E+03 1.23E+04 0.00 6.02E+04 1-130 7.60E+00 2.24E+01 8.85E+00 1.90E+03 3.50E+01 0.00 1.93E+01 1-131 1.73E+02 2.48E+02 1.42E+02 8.13E+04 4.25E+02 0.00 6.55E+01 1-132 5.27E-03 1.41E-02 4.93E-03 4.93E-01 2.24E-02 0.00 2.65E-03 1-133 2.59E+01 4.51E+01 1.37E+01 6.62E+03 7.86E+01 0.00 4.05E+01 1-134 2.18E-08 5.94E-08 2.12E-08 1.03E-06 9.44E-08 0.00 5.17E-11 1-135 1.31E+00 3.44E+00 1.27E+00 2.27E+02 5.52E+00 0.00 3.89E+00 Cs-134 2.98E+05 7.1OE+05 5.80E+05 0.00 2.30E+05 7.62E+04 1.24E+04 Cs-136 2.96E+04 1.17E+05 8.42E+04 0.00 6.51E+04 8.92E+03 1.33E+04 Cs-137 3.82E+05 5.23E+05 3.43E+05 0.00 1.78E+05 5.90E+04 1.01E+04 Cs-138 9.12E-12 1.80E-11 8.92E-12 0.00 1.32E-11 1.31E-12 7.68E-17 Ba-139 5.64E-06 4.02E-09 1.65E-07 0.00 3.76E-09 2.28E-09 1.00E-05 Ba-140 3.74E+02 4.69E-01 2.45E+01 0.00 1.60E-01 2.69E-01 7.69E+02 Ba-141 8.47E-25 6.40E-28 2.86E-26 0.00 5.95E-28 3.63E-28 3.99E-34 Ba-142 0.00 0.00 0.00 0.00 0.00 0.00 0.00 La-140 1.10E-01 5.56E-02 1.47E-02 0.00 0.00 0.00 4.08E+03 La-142 2.19E-07 9.96E-08 2.48E-08 0.00 0.00 0.00 7.27E-04 Ce-141 1.15E-01 7.79E-02 8.84E-03 0.00 3.62E-02 0.00 2.98E+02 Ce-143 8.65E-03 6.39E+00 7.08E-04 0.00 2.81E-03 0.00 2.39E+02 Ce-144 6.22E+00 2.60E+00 3.34E-01 0.00 1.54E+00 0.00 2.1OE+03 Pr-143 6.10E-01 2.44E-01 3.02E-02 0.00 1.41E-01 0.00 2.67E+03 Pr-144 1.48E-28 6.14E-29 7.51E-30 0.00 3.46E-29 0.00 2.13E-35 Nd-147 4.11E-01 4.75E-01 2.84E-02 0.00 2.78E-01 0.00 2.28E+03 W-187 1.47E+02 1.23E+02 4.31E+01 0.00 0.00 0.00 4.04E+04 Np-239 2.81E-02 2.76E-03 1.52E-03 0.00 8.62E-03 0.00 5.67E+02 2-37 VER 29 VEGP ODCM 2.5 LIQUID EFFLUENT DOSE PROJECTIONS 2.5.1 Thirty-One Day Dose Projections In order to meet the requirements for operation of the LIQUID RADWASTE TREATMENT SYSTEM (see Section 2.1.4), dose projections must be made at least once each 31 days; this applies during periods in which a discharge to UNRESTRICTED AREAS of liquid effluents containing radioactive materials occurs or is expected.Projected 31-day doses to individuals due to liquid effluents may be determined as follows: Dpj x31+ D,, (2.17)where: D~p = the projected dose to the total body or organ r, for the next 31 days of liquid releases.Dec = the cumulative dose to the total body or organ c, for liquid releases that have occurred in the elapsed portion of the current quarter, plus the release under consideration. t = the number of whole or partial days elapsed into the current quarter, including the time to the end of the release under consideration (even if the release continues into the next quarter).Dia = the anticipated dose contribution to the total body or any organ ',, due to any planned activities during the next 31-day period, if those activities will result in liquid releases that are in addition to routine liquid effluents. If only routine liquid effluents are anticipated, Dta may be set to zero.2.5.2 Dose Projections for Specific Releases Dose projections may be performed for a particular release by performing a prerelease dose calculation assuming that the planned release will proceed as anticipated. For individual dose projections due to liquid releases, follow the methodology of Section 2.4, using sample analysis results for the source to be released, and parameter values expected to exist during the release period.2-38 VER 29 VEGP ODCM 2.6 DEFINITIONS OF LIQUID EFFLUENT TERMS The following symbolic terms are used in the presentation of liquid effluent calculations in the subsections above.Section of Term Definition Initial Use Ap= the adjustment factor used in calculating the effluent monitor setpoint for liquid release pathway p: the ratio of the assured dilution to the required dilution [unitless]. 2.3.2.2 ADF = the assured dilution factor for a planned release [unitless]. 2.3.2.2 AFp = the dilution allocation factor for liquid release pathway p 2.3.2.2[unitless]. A, = the site-related adult ingestion dose commitment factor, for the total body or for any organ T, due to identified radionuclide i [(mrem
- mL)/(h * ýtCi)]. The values of Ai, are listed in Table 2-8. 2.4.1 Biv = the crop to soil concentration factor applicable to radionuclide i, [(pCi/kg garden vegetation)/(pCi/kg soil)]. 2.4.3 BFi = the bioaccumulation factor for radionuclide i for freshwater fish [(pCilkg)/(pCi/L)].
Values are listed in Table 2-6. 2.4.2 c = the setpoint of the radioactivity monitor measuring the concentration of radioactivity in the effluent line, prior to dilution and subsequent release [ptCi/mL]. 2.3.2.1 Cp= the calculated effluent radioactivity monitor setpoint for liquid release pathway p [gCi/mL]. 2.3.2.2 Ca -the gross concentration of alpha emitters in the liquid waste as measured in the applicable composite sample [giCi/mL]. 2.3.2.2 CECL -the Effluent Concentration Limit stated in 10 CFR 20, Appendix B, Table 2, Column 2 [giCi/mL]. 2.3.2.1 Cf= the concentration of Fe-55 in the liquid waste as measured in the applicable composite sample [gCi/mL]. 2.3.2.2 2-39 VER 29 VEGP ODCM Section of Term Definition Initial Use Cg= the concentration of gamma emitter g in the liquid waste as measured by gamma ray spectroscopy performed on the applicable prerelease waste sample [pfCi/mL]. 2.3.2.2 C = the measured concentration of radionuclide i in a sample of liquid effluent [VtCi/mL]. 2.3.2.2 CQ = the average concentration of radionuclide i in undiluted liquid effluent during time period / [jiCi/mL]. 2.4.1 Cir = the measured concentration of radionuclide i in release pathway r that is contributing to radioactivity in the dilution 2.3.2.2 stream [(,Ci/mL]. Cs = the concentration of strontium radioisotope s (Sr-89 or Sr-90) in the liquid waste as measured in the applicable composite sample [jiCi/mL]. 2.3.2.2 Ct = the concentration of H-3 in the liquid waste as measured in the applicable composite sample [[tCi/mL]. 2.3.2.2 CFi, = the concentration factor for radionuclide i in irrigated garden vegetation [(pCi/kg)/(pCi/L)]. 2.4.2 Dw= the dilution factor from the near field of the discharge structure to the potable water intake location [unitless]. 2.4.2 D = the cumulative dose commitment to the total body or to any organ c, due to radioactivity in liquid effluents released during a given time period [mrem]. 2.4.1 DOa = the anticipated dose contribution to the total body or any organ T, due to any planned activities during the next 31-day period [mrem]. 2.5.1 Dec = the cumulative dose to the total body or organ r, for liquid releases that have occurred in the elapsed portion of the current quarter, plus the release under consideration 2.5.1[mrem].2-40 VER 29 VEGP ODCM Term Definition D= the projected dose to the total body or organ c, for the next 31 days of liquid releases [mrem].DFi = the dose conversion factor for radionuclide i for adults, in organ t [mrem/pCi]. Values are listed in Table 2-7.ECL = the liquid Effluent Concentration Limit for radionuclide i from 10 CFR Part 20, Appendix B, Table 2, Column 2[gC i/m L.f = the effluent flowrate at the location of the radioactivity monitor [gpm].fap = the anticipated actual discharge flowrate for a planned release from liquid release pathway p [gpm].f= the fraction of the year that garden vegetation is irrigated [unitless]. fmp = the maximum permissible effluent discharge flowrate for release pathway p [gpm].fr = the effluent discharge flowrate of release pathway r [gpm].ft = the average undiluted liquid waste flowrate actually observed during the period of a liquid release [gpm].F = the dilution stream flowrate which can be assured prior to the release point to the UNRESTRICTED AREA [gpm].Fd = the entire assured dilution flowrate for the plant site during the release period [gpm].Fdp = the dilution flowrate allocated to release pathway p [gpm].F, = the near-field average dilution factor in the receiving water of the UNRESTRICTED AREA [unitless]. Ft = the average dilution stream flowrate actually observed during the period of a liquid release [gpm].I = the average irrigation rate during the growing season[L/(m 2.h)].Section of Initial Use 2.5.1 2.4.2 2.3.2.2 2.3.2.1 2.3.2.2 2.4.3 2.3.2.2 2.3.2.2 2.4.1 2.3.2.1 2.3.2.2 2.3.2.2 2.4.1 2.4.1 2.4.3 2-41 VER 29 VEGP ODCM Section of Term Definition Initial Use Lv = the water content of leafy garden vegetation edible parts 2.4.3[L/kg].M = the additional river dilution factor from the near field of the discharge structure for the plant site to the point of irrigation water usage [unitless]. 2.4.3 P = the effective surface density of soil [kg/M 2]. 2.4.3 r = the fraction of irrigation-deposited activity retained on the edible portions of leafy garden vegetation. 2.4.3 RDF = the required dilution factor: the minimum ratio by which liquid effluent must be diluted before reaching the UNRESTRICTED AREA, in order to ensure that the limits of Section 2.1.2 are not exceeded [unitless]. 2.3.2.2 RDFy = the RDF for a liquid release due only to its concentration of gamma-emitting radionuclides [unitless]. 2.3.2.2 RDFr = the RDF for a liquid release due only to its concentration of non-gamma-emitting radionuclides [unitless]. 2.3.2.2 SF = the safety factor selected to compensate for statistical fluctuations and errors of measurement [unitless]. 2.3.2.2 t = the number of whole or partial days elapsed into the current quarter, including the time to the end of the release under consideration. 2.5.1 tb = the period of long-term buildup of activity in soil [h]. 2.4.3 te = the period of leafy garden vegetation exposure during the growing season [h]. 2.4.3 tf = the transit time from release to receptor for fish 2.4.2 consumption [h].th = the time between harvest of garden vegetation and human consumption [h]. 2.4.3 tw= the transit time from release to receptor for potable water consumption [h]. 2.4.2 2-42 VER 29 VEGP ODCM Section of Term Definition Initial Use TF = the tolerance factor selected to allow flexibility in the establishment of a practical monitor setpoint which could accommodate effluent releases at concentrations higher than the ECL values stated in 10 CFR 20, Appendix B, Table 2, Column 2 [unitless]; the tolerance factor must not 2.3.2.1 exceed a value of 10.Uf = the adult rate of fish consumption [kg/y]. 2.4.2 Uv= the adult consumption rate for irrigated garden vegetation [kg/y]. 2.4.2 Uw= the adult drinking water consumption rate applicable to the plant site [L/y]. 2.4.2 YV = the areal density (agricultural productivity) of leafy garden vegetation [kg/M 2]. 2.4.3 Z = the applicable dilution factor for the receiving water body, in the near field of the discharge structure, during the period of radioactivity release [unitless]. 2.4.1 At 1 = the length of time period 1, over which Ci and F, are averaged for liquid releases [h]. 2.4.1 ,Ei = the effective removal rate for activity deposited on crop leaves [h-1]. 2.4.3= the decay constant for radionuclide i [h-1]. 2.4.2 k= the rate constant for removal of activity from plant leaves by weathering [h-1]. 2.4.3 2-43 VER 29 VEGP ODCM CHAPTER 3 GASEOUS EFFLUENTS 3.1 LIMITS OF OPERATION The following Limits of Operation implement requirements established by Technical Specifications Section 5.0. Terms printed in all capital letters are defined in Chapter 10.3.1.1 Gaseous Effluent Monitoring Instrumentation Control In accordance with Technical Specification 5.5.4.a, the radioactive gaseous effluent monitoring instrumentation channels shown in Table 3-1 shall be OPERABLE with their alarm/trip setpoints set to ensure that the limits of Section 3.1.2.a are not exceeded.The alarm/trip setpoints of these channels shall be determined in accordance with Section 3.3.3.1.1.1 Applicability These limits apply as shown in Table 3-1.3.1.1.2 Actions With a radioactive gaseous effluent monitoring instrumentation channel alarm/trip setpoint less conservative than required by the above control, immediately suspend the release of radioactive gaseous effluents monitored by the affected channel, declare the channel inoperable, or restore the setpoint to a value that will ensure that the limits of Section 3.1.2.a are met.With less than the minimum number of radioactive gaseous effluent monitoring instrumentation channels OPERABLE, take the ACTION shown in Table 3-1. Restore the inoperable instrumentation to operable status within 30 days, or if unsuccessful, explain in the next Radioactive Effluent Release Report, per Technical Specification 5.6.3, why this inoperability was not corrected in a timely manner.This control does not affect shutdown requirements or MODE changes.3.1.1.3 Surveillance Requirements Each radioactive gaseous effluent monitoring instrumentation channel shall be demonstrated OPERABLE by performance of the CHANNEL CHECK, SOURCE CHECK, CHANNEL CALIBRATION and CHANNEL OPERATIONAL TEST operations at the frequencies shown in Table 3-2.3-1 VER 29 VEGP ODCM 3.1.1.4 Basis The radioactive gaseous effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in gaseous effluents during actual or potential releases of gaseous effluents. The Alarm/Trip Setpoints for these instruments shall be calculated and adjusted in accordance with the methodology and parameters in Section 3.3 to ensure that the alarm/trip will occur prior to exceeding the limits of Section 3.1.2.a. The OPERABILITY and use of this instrumentation is consistent with the requirements of General Design Criteria 60, 63, and 64 of Appendix A to 10 CFR Part 50.3-2 VER 29 VEGP ODCM Table 3-1. Radioactive Gaseous Effluent Monitoring Instrumentation OPERABILITY Requirements Minimum Instrument Channels OPERABLE Applicability ACTION 1. GASEOUS RADWASTE TREATMENT SYSTEM (Common)a. Noble Gas Activity Monitor, with Alarm and Automatic Termination of Release (ARE-0014) 1 During releases' 45 b. Effluent System Flowrate Measuring Device (AFT-0014) 1 During releasesa 46 2. Turbine Building Vent (Each Unit)a. Noble Gas Activity Monitor (RE-1 2839C) 1 During releasesa 4a b. Iodine and Particulate Samplers (RE-12839A & B) 1 During releases' 51 c. Flowrate Monitor (FT-1 2839 or FIS-1 2 8 6 2)b 1 During releasesa 46 d. Sampler Flowrate Monitor (1FI-13211, 2FIT-13211) 1 During releasesa 46 3. Plant Vent (Each Unit)a. Noble Gas Activity Monitor (RE-1 2442C or RE-1 2444C) 1 At all times 47,48 b. Iodine Sampler/Monitor (RE-12442B or RE-12444B) 1 At all times 51 c. Particulate Sampler/Monitor (RE-1 2442A or RE-12444A) 1 At all times 51 d. Flowrate Monitor (FT-12442 or 12835) 1 At all times 46 e. Sampler Flowrate Monitor (FI-12442 or FI-12444) 1 At all times 46 4. Radwaste Processing Facility Vent (Common)a. Particulate Monitor (ARE-1 6980) 1 1 During releasesa 51 a. "During releases" means "During radioactive releases via this pathway." b. During emergency filtration. 3-3 VER 29 VEGP ODCM Table 3-1 (contd). Notation for Table 3-1 -ACTION Statements ACTION 45 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, the contents of the tank(s) may be released to the environment for up to 14 days provided that prior to initiating the release: a. The local radiation monitor reading (if functional) is recorded at least once per 12 hours or at least two independent samples of the tank's contents are analyzed, and b. At least two technically qualified members of the Facility Staff independently verify the discharge line valving, and verify the release rate calculations. Otherwise, suspend release of radioactive effluents via this pathway.ACTION 46 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway may continue provided the flowrate is estimated at least once per 4 hours.ACTION 47 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway may continue provided the local radiation monitor reading (if functional) is recorded at least once per 12 hours or grab samples are taken at least once per 12 hours and these samples are analyzed for radioactivity within 24 hours. With the plant vent radiation monitor iodine and particulate channels inoperable during the loss of sample line heat tracing, the noble gas channel of RE-1 2442 and RE-12444 would still be considered valid.ACTION 48 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, record the local radiation monitor reading (if functional) for RE-2565C at least once per 12 hours or immediately suspend containment purging of radioactive effluents via this pathway.ACTION 49 -(Not Used)ACTION 50 -(Not Used)ACTION 51 -With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via the affected pathway may continue provided one of the following options is available (1) the 3-4 VER 29 VEGP ODCM local radiation monitor reading (if functional) is recorded at least once per 12 hours (2) samples are continuously collected with the installed skid or (3)samples are continuously collected with auxiliary sampling equipment. RE-12444A and B may be verified functional by recording local radiation monitor skid flow once per 12 hours. With the plant vent radiation monitor particulate and iodine channels inoperable during the loss of sample line heat tracing, estimate radioactive releases for up to 48 hours while continuing to monitor noble gas activity from RE-1 2442 and RE-1 2444.3-5 VER 29 VEGP ODCM Table 3-2. Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements Surveillance Requirements CHANNEL Instrument CHANNEL OPERA-CHANNEL SOURCE CALIBRA- TIONAL CHECK CHECK TION TEST MODESc 1. GASEOUS RADWASTE TREATMENT SYSTEM (Common)a. Noble Gas Activity Monitor, with Alarm and Automatic Termination of Release During (ARE-0014) P P Rb Ra(') Release b. Effluent System Flowrate Measuring Device During (AFT-0014) P NA R NA Release 2. Turbine Building Vent (Each Unit)a. Noble Gas Activity Monitor During (RE-12839C) D M Rb Ra(2) Release b. Iodine and Particulate During Samplers (RE-12839A&B) Wd NA NA NA Release c. Flowrate Monitor During (FT-12839 or FIS-12862) D NA R NA Release d. Sampler Flowrate Monitor During (1FI-13211, 2FIT-13211) D NA R Q Release 3. Plant Vent (Each Unit)a. Noble Gas Activity Monitor (RE-1 2442C or RE-12444C) D M Rb Ra(2) All b. Particulate and Iodine Monitors (RE-12442A&B) Wd NA R Ra(2) All c. Particulate and Iodine Samplers (RE-12444A&B) 'Nd NA NA NA All d. Flowrate Monitor (FT-12442 or 12835) D NA R NA All e. Sampler Flowrate Monitor (FI-12442 or Fl-12444) D NA R Q All 4. Radwaste Processing Facility Vent (Common)a. Particulate Monitor Wd Q Re N/A During (ARE-16980) Release 3-6 VER 29 VEGP ODCM Table 3-2 (contd). Notation for Table 3-2 a. In addition to the basic functions of a CHANNEL OPERATIONAL TEST (Section 10.2): (1) The CHANNEL OPERATIONAL TEST shall also demonstrate that automatic isolation of this pathway and control room annunciation occurs (for item a. below only); and control room CRT indication occurs (if any of the following conditions exist): (a) Instrument indicates measured levels above the alarm/trip setpoint;(b) Instrument indicates an "Equipment Trouble" alarm;(c) Instrument indicates a "Low" alarm; or (d) Instrument indicates channel "Deactivated." (2) The CHANNEL OPERATIONAL TEST shall also demonstrate that control room annunciation occurs (for item a. below only); and that control room CRT indication occurs (if any of the following conditions exist): (a) Instrument indicates measured levels above the alarm/trip setpoint;(b) Instrument indicates an "Equipment Trouble" alarm;(c) Instrument indicates a "Low" alarm; or (d) Instrument indicates channel "Deactivated." ("Loss of counts" for ARE-16980 only)b. The initial CHANNEL CALIBRATION shall be performed using one or more of the reference standards certified by the National Institute of Standards and Technology, or using standards that have been obtained from suppliers that participate in measurement assurance activities with NIST. These standards shall permit calibrating the system over its intended range of energy and measurement range. For any subsequent CHANNEL CALIBRATION, sources that have been related to the initial calibration shall be used.c. MODES in which surveillance is required. "All" means "At all times." "During release" means "During radioactive release via this pathway." 3-7 VER 29 VEGP ODCM d. The channel check shall consist of visually verifying that the collection device (i.e., particulate filter or charcoal cartridge, etc.) is in place for sampling.e. The CHANNEL CALIBRATION verifies proper operation of the CHANNEL OPERATIONAL TEST requirements described in Notation a(2) above.3-8 VER 29 VEGP ODCM 3.1.2 Gaseous Effluent Dose Rate Control In accordance with Technical Specifications 5.5.4.c and 5.5.4.g, the licensee shall conduct operations so that the dose rates due to radioactive materials released in gaseous effluents from the site to areas at and beyond the SITE BOUNDARY are limited as follows: a. For noble gases: Less than or equal to a dose rate of 500 mrem/y to the total body and less than or equal to a dose rate of 3000 mrem/y to the skin, and b. For Iodine-1 31, Iodine-1 33, tritium, and for all radionuclides in particulate form with half-lives greater than 8 days: Less than or equal to a dose rate of 1500 mrem/y to any organ.3.1.2.1 Applicability This limit applies at all times.3.1.2.2 Actions With a dose rate due to radioactive material released in gaseous effluents exceeding the limit stated in Section 3.1.2, immediately decrease the release rate to within the stated limit.These limits do not affect shutdown requirements or MODE changes.3.1.2.3 Surveillance Requirements The dose rates due to radioactive materials in areas at or beyond the SITE BOUNDARY due to releases of gaseous effluents shall be determined to be within the above limits, in accordance with the methods and procedures in Section 3.4.1, by obtaining representative samples and performing analyses in accordance with the sampling and analysis program specified in Table 3-3.3.1.2.4 Basis This control is provided to ensure that gaseous effluent dose rates will be maintained within the limits that historically have provided reasonable assurance that radioactive material discharged in gaseous effluents will not result in a dose to a MEMBER OF THE PUBLIC in an UNRESTRICTED AREA, either within or outside the SITE BOUNDARY, exceeding the limits specified in Appendix I of 10 CFR Part 50, while allowing operational flexibility for effluent releases. For MEMBERS OF THE PUBLIC who may at times be within the SITE BOUNDARY, the occupancy of the MEMBER OF THE PUBLIC will be sufficiently low to compensate for any increase in the atmospheric diffusion factor above that for the SITE BOUNDARY.3-9 VER 29 VEGP ODCM The dose rate limit for Iodine-1 31, Iodine-1 33, tritium, and radionuclides in particulate form with half-lives greater than 8 days specifically applies to dose rates to a child via the inhalation pathway.This control applies to the release of gaseous effluents from all reactors at the site.3-10 VER 29 VEGP ODCM Table 3-3. Radioactive Gaseous Waste Sampling and Analysis Program Sampling and Analysis Requirementsa MINIMUM DETECTABLE Minimum CONCENTRA-Gaseous Sampling Analysis Type of Activity TION (MDC)Release Type FREQUENCY FREQUENCY Analysis (jtCi/mL)Waste Gas P P Noble Gas 1 E-4 Decay Tank Each Tank Grab Each Tank PRINCIPAL (Common) Sample GAMMA EMITTERS pi Noble Gas 1 E-4 Containment pC Each Furge PRINCIPAL Purge 14, Each Purge GAMMA EMITTERS 24" or14 (Each Unit) Grab Sample M H-3 (Oxide) 1 E-6 Noble Gas 1 E-4 Plant Vent Mc'd'f MC PRINCIPAL (Each Unit) Grab Sample GAMMA EMITTERS H-3 (Oxide) 1 E-6 Condenser Air Noble Gas 1 E-4 PRINCIPAL Ejector & MGAMMA EMITTERS Steam Packing Mple M Exhaust Grab Sample (Each Unit)b H-3 (Oxide) 1 E-6 we Charcoal 1-131 1 E-12 CONTINUOUS 8 or Silver Zeolite Sample We Particulate 1 E-11 CONTINUOUS Particulate PRINCIPAL Sample GAMMA EMITTERS Plant Vent, M Gross Alpha 1 E-1 1 Condenser Air COMPOSITE Ejector & Particulate Steam Packing CONTINUOUS 8 arile Exhaust (Each Sample Unit)b Q Sr-89, Sr-90 1 E-1 1 CONTINUOUS 8 COMPOSITE Particulate Sample Radwaste Wh Particulate 1 E-11 Processing Particulate PRINCIPAL Facility Vent CONTINUOUS 8 Sample GAMMA EMITTERS (Common)3-11 VER 29 VEGP ODCM Table 3-3 (contd). Notation for Table 3-3 a. Terms printed in all capital letters are defined in Chapter 10.b. The turbine building vent is the release point for the condenser air ejector and steam packing exhaust. All sampling and analyses may be omitted for this vent, provided the absence of a primary to secondary leak has been demonstrated, that is, if the gamma activity in the secondary water does not exceed background by more than 20%.c. Sampling and analysis shall also be performed following shutdown, startup, or a THERMAL POWER change exceeding 15% of the RATED THERMAL POWER within a one-hour period. This requirement does not apply if (1) analysis shows that the DOSE EQUIVALENT 1-131 concentration in the primary coolant has not increased more than a factor of 3; and (2) the noble gas monitor shows that effluent activity has not increased more than a factor of 3.d. Tritium grab samples shall be taken at least once per 24 hours when the refueling cavity is flooded.e. Samples shall be changed at least once per 7 days and analyses shall be completed within 48 hours after changing (or after removal from sampler).Sampling shall also be performed at least once per 24 hours for at least 7 days following each shutdown, startup, or THERMAL POWER change exceeding 15%of RATED THERMAL POWER in one hour, and analyses shall be completed within 48 hours of changing. When samples collected for 24 hours are analyzed, the corresponding MDC may be increased by a factor of 10. This requirement does not apply if (1) analysis shows that the DOSE EQUIVALENT 1-131 concentration in the primary coolant has not increased more than a factor of 3;and (2) the noble gas monitor shows that effluent activity has not increased more than a factor of 3.f. Tritium grab samples shall be taken at least once per 7 days from the Unit 1 plant vent, whenever spent fuel is in the spent fuel pool (Unit 1 plant vent only).g. The ratio of the sample flowrate to the sampled stream flowrate shall be known for the time period covered by each dose or dose rate calculation made in accordance with controls specified in Sections 3.1.2, 3.1.3, and 3.1.4.h. Samples shall be changed at least once per 7 days and analyses shall be completed within 48 hours after changing (or removal of sampler).3-12 VER 29 VEGP ODCM 3-13 VER 29 VEGP ODCM 3.1.3 Gaseous Effluent Air Dose Control In accordance with Technical Specifications 5.5.4.e and 5.5.4.h, the air dose due to noble gases released in gaseous effluents, from each reactor unit, to areas at and beyond the SITE BOUNDARY shall be limited to the following:
- a. During any calendar quarter: Less than or equal to 5 mrad for gamma radiation and less than or equal to 10 mrad for beta radiation, and b. During any calendar year: Less than or equal to 10 mrad for gamma radiation and less than or equal to 20 mrad for beta radiation.
3.1.3.1 Applicability This limit applies at all times.3.1.3.2 Actions With the calculated air dose from radioactive noble gases in gaseous effluents exceeding any of the above limits, prepare and submit to the Nuclear Regulatory Commission within 30 days a special report which identifies the cause(s) for exceeding the limit(s); defines the corrective actions that have been taken to reduce the releases;and defines the proposed corrective actions to be taken to assure that subsequent releases of radioactive noble gases in gaseous effluents will be in compliance with the limits of Section 3.1.3.This control does not affect shutdown requirements or MODE changes.3.1.3.3 Surveillance Requirements Cumulative air dose contributions from noble gas radionuclides released in gaseous effluents from each unit to areas at and beyond the SITE BOUNDARY, for the current calendar quarter and current calendar year, shall be determined in accordance with Section 3.4.2 at least once per 31 days.3.1.3.4 Basis This control is provided to implement the requirements of Sections 1I.B, III.A and IV.A of Appendix I, 10 CFR Part 50. Section 3.1.3 implements the guides set forth in Section ll.B of Appendix I. The ACTION statements in Section 3.1.3.2 provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I, assuring that the releases of radioactive material in gaseous effluents to UNRESTRICTED AREAS will be kept "as low as is reasonably achievable." The Surveillance requirements in Section 3.1.3.3 implement the requirements in Section III.A of Appendix I, which require that conformance with the guides of Appendix I be shown 3-14 VER 29 VEGP ODCM by calculational procedures based on models and data such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated. The dose calculations established in Section 3.4.2 for calculating the doses due to the actual releases of noble gases in gaseous effluents are consistent with the methodology provided in Regulatory Guide 1.109 (Reference 3), and Regulatory Guide 1.111 (Reference 5). The equations in Section 3.4.2 provided for determining the air doses at the SITE BOUNDARY are based upon the historical annual average atmospheric conditions.
3.1.4 Control
on Gaseous Effluent Dose to a Member of the Public In accordance with Technical Specifications 5.5.4.e and 5.5.4.i, the dose to a MEMBER OF THE PUBLIC from 1-131, 1-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents released, from each reactor unit, to areas at and beyond the SITE BOUNDARY shall be limited to the following:
- a. During any calendar quarter: Less than or equal to 7.5 mrem to any organ, and b. During any calendar year: Less than or equal to 15 mrem to any organ.3.1.4.1 Applicability This limit applies at all times.3.1.4.2 Actions With the calculated dose from the release of 1-131, 1-133, tritium, or radionuclides in particulate form with half-lives greater than 8 days, in gaseous effluents exceeding any of the above limits, prepare and submit to the Nuclear Regulatory Commission within 30 days a special report which identifies the cause(s) for exceeding the limit; defines the corrective actions that have been taken to reduce the releases of radioiodines and radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents; and defines proposed corrective actions to assure that subsequent releases will be in compliance with the limits stated in Section 3.1.4.This control does not affect shutdown requirements or MODE changes.3.1.4.3 Surveillance Requirements Cumulative organ dose contributions to a MEMBER OF THE PUBLIC from 1-131, 1-133, tritium, and radionuclides in particulate form with half-lives greater than 8 days released in gaseous effluents from each unit to areas at and beyond the SITE BOUNDARY, for the current calendar quarter and current calendar year, shall be determined in accordance with Section 3.4.3 at least once per 31 days.3.1.4.4 Basis 3-15 VER 29 VEGP ODCM This control is provided to implement the requirements of Section II.C, III.A and IV.A of Appendix 1, 10 CFR Part 50. The limits stated in Section 3.1.4 are the guides set forth in Section II.C of Appendix I. The ACTION statements in Section 3.1.4.2 provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive materials in gaseous effluents to UNRESTRICTED AREAS will be kept "as low as is reasonably achievable." The calculational methods specified in the Surveillance Requirements of Section 3.1.4.3 implement the requirements in Section III.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data, such that the actual exposure of a MEMBER OF THE PUBLIC through appropriate pathways is unlikely to be substantially underestimated.
The calculational methods in Section 3.4.3 for calculating the doses due to the actual releases of the subject materials are consistent with the methodology provided in Regulatory Guide 1.109 (Reference 3), and Regulatory Guide 1.111 (Reference 5).These equations provide for determining the actual doses based upon the historical annual average atmospheric conditions. The release specifications for radioiodines, radioactive materials in particulate form and radionuclides other than noble gases are dependent on the existing radionuclide pathways to man, in the areas at and beyond the SITE BOUNDARY. The pathways which were examined in the development of these calculations were: 1) individual inhalation of airborne radionuclides, 2) deposition of radionuclides onto green leafy garden vegetation with subsequent consumption by man, 3) deposition onto grassy areas where milk animals and meat producing animals graze with consumption of the milk and meat by man, and 4) deposition on the ground with subsequent exposure of man.3.1.5 Gaseous Radwaste Treatment System Control In accordance with Technical Specification 5.5.4.f, the GASEOUS WASTE PROCESSING SYSTEM and the VENTILATION EXHAUST TREATMENT SYSTEM shall be OPERABLE. The appropriate portions of the GASEOUS WASTE PROCESSING SYSTEM and the VENTILATION EXHAUST TREATMENT SYSTEM shall be used to reduce radioactive materials in gaseous wastes prior to their discharge when the projected doses in 31 days due to gaseous effluent releases, from each reactor unit, to areas at and beyond the SITE BOUNDARY would exceed 0.2 mrad to air from gamma radiation, 0.4 mrad to air from beta radiation, or 0.3 mrem to any organ of a MEMBER OF THE PUBLIC.3.1.5.1 Applicability These limits apply at all times.3.1.5.2 Actions 3-16 VER 29 VEGP ODCM With gaseous waste being discharged without treatment and in excess of the limits in Section 3.1.5, prepare and submit to the Nuclear Regulatory Commission within 30 days a special report which includes the following information:
- a. Identification of any inoperable equipment or subsystem and the reason for inoperability, b. Action(s) taken to restore the inoperable equipment to OPERABLE status, and c. Summary description of action(s) taken to prevent a recurrence.
This control does not affect shutdown requirements or MODE changes.3.1.5.3 Surveillance Requirements Doses due to gaseous releases from each unit to areas at and beyond the SITE BOUNDARY shall be projected at least once per 31 days, in accordance with Section 3.5.1, when the GASEOUS WASTE PROCESSING SYSTEM or the VENTILATION EXHAUST TREATMENT SYSTEM is not being fully utilized.The GASEOUS WASTE PROCESSING SYSTEM and the VENTILATION EXHAUST TREATMENT SYSTEM shall be demonstrated OPERABLE: by meeting the controls of Sections 3.1.2, and either 3.1.3 (for the GASEOUS WASTE PROCESSING SYSTEM) or 3.1.4 (for the VENTILATION EXHAUST TREATMENT SYSTEM).3.1.5.4 Basis The OPERABILITY of the GASEOUS WASTE PROCESSING SYSTEM ensures that the system will be available for use whenever gaseous effluents require treatment prior to release to the environment. The requirement that the appropriate portions of this system be used, when specified, provides reasonable assurance that the releases of radioactive materials in gaseous effluents will be kept "as low as is reasonably achievable." This control implements the requirements of 10 CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR Part 50, and the design objectives given in Section IL.D of Appendix I to 10 CFR Part 50. The specified limits governing the use of appropriate portions of the system were specified as a suitable fraction of the dose design objectives set forth in Section II.B and II.C of Appendix 1, 10 CFR Part 50, for gaseous effluents. This control applies to the release of radioactive materials in gaseous effluents from each unit at the site. For units with shared radwaste treatment systems, the gaseous effluents from the shared system are proportioned among the units sharing that system.3-17 VER 29 VEGP ODCM 3.1.6 Major Changes to Gaseous Radioactive Waste Treatment Systems Licensee initiated MAJOR CHANGES TO GASEOUS RADIOACTIVE WASTE TREATMENT SYSTEMS: a. Shall be reported to the Nuclear Regulatory Commission in the Radioactive Effluents Release Report for the period in which the change was implemented. The discussion of each change shall contain the information described in Section 7.2.2.7.b. Shall become effective upon review and approval by the Vice President -Plant.3-18 VER 29 VEGP ODCM 3.2 GASEOUS WASTE PROCESSING SYSTEM At Plant Vogtle, there are five potential points where radioactivity may be released to the atmosphere in gaseous discharges. These five potential release pathways are the Unit 1 and Unit 2 Plant Vents; the Unit 1 and Unit 2 Turbine Building Vents; and the Radwaste Processing Facility Vent. However, the Turbine Building Vents are not normal release pathways unless a primary-to-secondary leak exists. The Radwaste Processing Facility Vent is not a normal release pathway unless a spill occurs. The figures on the following pages give schematic diagrams of the Gaseous Waste Treatment System and the Ventilation Exhaust Treatment Systems (Reference 11).The Unit 1 Plant Vent release pathway includes two release sources that are common to the two units: ventilation air from the Fuel Handling Building, and discharges from the GASEOUS WASTE PROCESSING SYSTEM. Otherwise, discharges from the two reactor units are separated. Reactor Containment Building ventilation releases are through the respective plant vents. The Turbine Building Vent serves as the discharge point for both the condenser air ejector and the steam packing exhauster system. The Radwaste Processing Facility Vent includes sources from the Radwaste Processing Facility Process area.Releases from the two Turbine Building Vents and the Radwaste Processing Facility Vent are considered to be ground-level releases, whereas releases from the two Plant Vents are considered mixed-mode releases. Chapter 8 discusses the calculation of atmospheric dispersion parameters using the ground-level and mixed-mode (i.e., split-wake) models. All five potential release pathways are considered to be continuous (as opposed to batch) in nature.3-19 VER 29 VEGP ODCM Radioactivity Monitor ARE-0014 To Unit 1 Plant Vent via Auxiliary Building Ventilation System To Chemical Volume Control Tank To Waste Gas Decay Tank Header I I I I Unit 2 Waste Gas Volume Control Tank Purge Recycle Evaporator Vent Condenser Waste Evaporator Vent Condenser Recycle Holdup Tank Eductor Reactor Coolant Drain Tank*Dotted line operational between 20 and 100 psig NOTE: This is typical of both units. However, Unit 2 GWPS releases via Unit 1 plant vent.Figure 3-1.Schematic Diagram of the Gaseous Radwaste Treatment System 3-20 VER 29 VEGP ODCM Plant Vent Radioactivity Monitor I RE12442A,B,C HEARE 255,,C Fe HEanlg iT I I CF I CF I CF I I I HEPA /HEPAI HEPA Radioactivi R Ctor ty Monitor I I RE 0039A M Auxiliary )Building Radioactivity Monitor I RE2565A,B,C Fuel Handling ( ) ( )Building CF (Shared)*HC HetingCiReactor ME Moistur ElMinator t tr y Mthe FuContainment ARE-0014 From Waste Gas Processing Area and temSystem HEPA -High-Efficiency Particulate Air Filter CF -Activated Charcoal Filter HC -Heating Coil ME -Moisture Eliminator
- Prior to treatment by the Fuel Handling Building Ventilation Exhaust Treatment System, Exhaust from Unit I Spent Fuel Pool Area is monitored by ARE2532B and ARE2533B; exhaust from Unit 2 Spent Fuel Pool Area is monitored by ARE2532A and ARE2533A.Figure 3-2. Schematic Diagram of the Unit 1 Plant Vent Release Pathway 3-21 VER 29 VEGP ODCM Plant Vent I 3-22 VER 29 VEGP ODCM 0 Radioactivity Monitor 2RE12442A,B,C Auxiliary Building Radioactivity Monitor Reactor Containment HEPA -High-Efficiency Particulate Air Filter CF -Activated Charcoal Filter HC -Heating Coil ME -Moisture Eliminator Figure 3-3. Schematic Diagram of the Unit 2 Plant Vent Release Pathway 3-23 VER 29 VEGP ODCM Turbine Building Radioactivity Monitor I(2)RE12839A,B,C NC Steam Jet Air Steam Packing HEPA -High-Efficiency Particulate Air Filter CF -Activated Charcoal Filter HC -Heating Coil DE -Demister NO -Normally Open NC -Normally Closed NOTE: This is typical of both units.Figure 3-4.Schematic Diagram of the Turbine Building Vent Release Pathway (Typical of Both Units)3-24 VER 29 VEGP ODCM Raciwaste Proc:cssing Facility Vent Radioaclivity Monitor ARE 16980 IIEPA Radwastc PJOcclsiDs Facility Proee:u Area-Room 101 Figure 3-5. Schematic Diagram of the Radwaste Processing Facility Ventilation Release Pathway 3-25 VER 29 VEGP ODCM 3.3 GASEOUS EFFLUENT MONITOR SETPOINTS 3.3.1 General Provisions Regarding Noble Gas Monitor Setpoints Noble gas radioactivity monitor setpoints calculated in accordance with the methodology presented in this section are intended to ensure that the limits of Section 3.1.2.a are not exceeded.
They will be regarded as upper bounds for the actual high alarm setpoints. That is, a lower high alarm setpoint may be established or retained on the monitor, if desired. Intermediate level setpoints should be established at an appropriate level to give sufficient warning prior to reaching the high alarm setpoint.If no release is planned for a given pathway, or if there is no detectable activity in the gaseous stream being evaluated for release, the setpoint should be calculated in accordance with the methods presented below, based on an assumed concentration of Kr-88 that leads to a practical setpoint. A practical setpoint in this context is one which prevents spurious alarms, and yet produces an alarm should a significant inadvertent release occur.Section 3.1.1 establishes the requirements for gaseous effluent monitoring instrumentation, and Section 3.2 describes the VENTILATION EXHAUST TREATMENT SYSTEM and the GASEOUS WASTE PROCESSING SYSTEM. From those Sections, it can be seen that certain monitors are located on final release pathways, that is, streams that are being monitored immediately before being discharged from the plant;the setpoint methodology for these monitors is presented in Section 3.3.2. Other monitors are located on source streams, that is, streams that merge with other streams prior to passing a final monitor and being discharged; the setpoint methodology for these monitors is presented in Section 3.3.3. Table 3-4 identifies which of these setpoint methodologies applies to each monitor. Some additional monitors with special setpoint requirements are discussed in Section 3.3.5.As established in Section 3.1.1, gaseous effluent monitor setpoints are required only for the noble gas monitors on certain potential release streams: the two Plant Vents, the two Turbine Building Vents, and the GASEOUS WASTE PROCESSING SYSTEM discharge. However, because of the potential significance of releases from other sources, Section 3.3 discusses setpoint methodologies for certain additional monitors, as well.3-20 VER 29 VEGP ODCM Table 3-4. Applicability of Gaseous Monitor Setpoint Methodologies Final Release Pathways with no Monitored Source Streams Setpoint Method: Release Elevation: Section 3.3.2 Ground-level Unit 1 or Unit 2 Turbine Building Vent Monitor: Maximum Flowrate: 1 RE-12839C/2RE-12839C 900 cfm (4.25 E+05 mL/s)Final Release Pathways with One or More Monitored Source Streams Release Elevation: Mixed-Mode Unit 1 Plant Vent Monitors: Maximum Flowrate: Setpoint Method: Release Type: 1 RE-12442C, 1 RE-12444C 187,000 cfm (8.83 E+07 mL/s)Section 3.3.2 CONTINUOUS Source Stream: Unit 1 Reactor Containment Puraqe Monitor: 1 RE-2565C Maximum Flowrate: release-dependent Setpoint Method: Section 3.3.3 Release Type: BATCH Source Stream: Gaseous Waste Treatment System Monitor: Maximum Flowrate: Setpoint Method: Release Type: Unit 2 Plant Vent Monitors: Maximum Flowrate: Setpoint Method: Release Type: ARE-0014 release-dependent Section 3.3.3 BATCH 2RE-12442C, 2RE-12444C 112,500 cfm (5.31 E+07 mL/s)Section 3.3.2 CONTINUOUS Source Stream: Unit 2 Reactor Containment Purge Monitor: Maximum Flowrate: Setpoint Method: Release Type: 2RE-2565C release-dependent Section 3.3.3 BATCH (X3-Q-vb Values for Use in Setpoint Calculations Ground-Level Releases: Mixed-Mode Releases: 2.55 x 10-6 s/m 3 [NE Sector]4.62 x 10-7 s/m 3[NE Sector]Maximum flowrate values are from Reference 11, Table 11.5.2-1 and Table 11.5.5-1.3-21 VER 29 VEGP ODCM 3.3.2 Setpoint for the Final Noble Gas Monitor on Each Release Pathway 3.3.2.1 Overview of Method Gaseous effluent radioactivity monitors are intended to alarm prior to exceeding the limits of Section 3.1.2.a. Therefore, their alarm setpoints are established to ensure compliance with the following equation: flAG. ~SF .X .Rt c =the lesser of AG. (3.1)LAG.SF.X.Rk where: c = the setpoint, in jtCi/mL, of the radioactivity monitor measuring the concentration of radioactivity in the effluent line prior to release. The setpoint represents a concentration which, if exceeded, could result in dose rates exceeding the limits of Section 3.1.2.a at or beyond the SITE BOUNDARY.AG = an administrative allocation factor applied to divide the release limit among all the gaseous release pathways at the site.SF = the safety factor selected to compensate for statistical fluctuations and errors of measurement. X = the noble gas concentration for the release under consideration. Rt = the ratio of the dose rate limit for the total body, 500 mrem/y, to the dose rate to the total body for the conditions of the release under consideration. Rk = the ratio of the dose rate limit for the skin, 3000 mrem/y, to the dose rate to the skin for the conditions of the release under consideration. Equation (3.1) shows the relationships of the critical parameters that determine the setpoint. However, in order to apply the methodology presented in the equation to a mixture of noble gas radionuclides, radionuclide-specific concentrations and dose factors must be taken into account under conditions of maximum flowrate for the release point and annual average meteorology. The basic setpoint method presented below is applicable to the radioactivity monitor nearest the point of release for the release pathway. For monitors measuring the radioactivity in source streams that merge with other streams prior to subsequent monitoring and release, the modifications presented in Section 3.3.3 must be applied.3-22 VER 29 VEGP ODCM 3.3.2.2 Setpoint Calculation Steps Step 1: Determine the concentration, Xjv, of each noble gas radionuclide i in the gaseous stream v being considered for release, in accordance with the sampling and analysis requirements of Section 3.1.2. Then sum these concentrations to determine the total noble gas concentration, YXjv.Step 2: Determine Rt, the ratio of the dose rate limit for the total body, 500 mrem/y, to the total body dose rate due to noble gases detected in the release under consideration, as follows: Rt= 500 (3.2)(7-)vb y K-Qv where: 500 = the dose rate limit for the total body, 500 mrem/y.FXIQ)vb = the highest annual average relative concentration at the SITE BOUNDARY for the discharge point of release pathway v. Table 3-4 includes an indication of what release elevation is applicable to each release pathway; release elevation determines the appropriate value of FxQ)Vb *Ki = the total-body dose factor due to gamma emissions from noble gas radionuclide i, in (mrem/y)/(p.Ci/m 3), from Table 3-5.Qiv = the release rate of noble gas radionuclide i from the release pathway under consideration, in [tCi/s, calculated as the product of Xiv and fav, where: Xi = the concentration of noble gas radionuclide i for the particular release, in p.Ci/mL.fav = the maximum anticipated flowrate for release pathway v during the period of the release under consideration, in mL/s.Step 3: Determine Rk, the ratio of the dose rate limit for the skin, 3000 mrem/y, to the skin dose rate due to noble gases detected in the release under consideration, as follows: 3000 (3.3)(X/Q-),h Y_ [(L' + 1. 1M).Q I 3-23 VER 29 VEGP ODCM where: 3000 = the dose rate limit for the skin, 3000 mrem/y.Li = the skin dose factor due to beta emissions from noble gas radionuclide i, in (mrem/y)/(ptCi/m3), from Table 3-5.= the air dose factor due to gamma emissions from noble gas radionuclide i, in (mrad/y)I(ý.Ci/m3), from Table 3-5.1.1 = the factor to convert air dose in mrad to skin dose in mrem.All other terms were defined previously. Step 4: Determine the maximum noble gas radioactivity monitor setpoint concentration. Based on the values determined in previous steps, the radioactivity monitor setpoint for the planned release is calculated to ensure that the limits of Section 3.1.2.a will not be exceeded. Because the radioactivity monitor responds primarily to radiation from noble gas radionuclides, the monitor setpoint Cnv (in [tCi/mL) is based on the concentration of all noble gases in the waste stream, as follows: where: Cnv = the calculated setpoint, in ý.Ci/mL, for the noble gas monitor serving gaseous release pathway v.SAG
- SF" YX,, " R, c,,,,= the lesser of (3.4)LAG
- SF.EXiV ARA i AGv = the administrative allocation factor for gaseous release pathway v, applied to divide the release limit among all the gaseous release pathways at the site. The allocation factor may be assigned any value between 0 and 1, under the condition that the sum of the allocation factors for all simultaneously-active final release pathways at the entire plant site does not exceed 1. Alternative methods for determination of AGv are presented in Section 3.3.4.SF = the safety factor selected to compensate for statistical fluctuations and errors of measurement.
The value for the safety factor must be between 0 and 1. A value of 0.5 is reasonable for gaseous releases;a more precise value may be developed if desired.3-24 VER 29 VEGP ODCM Xiv = the measured concentration of noble gas radionuclide i in gaseous stream v, as defined in Step 1, in [tCi/mL.The values of Rt and Rk to be used in the calculation are those which were determined in Steps 2 and 3 above.Step 5: Determine whether the release is permissible, as follows: If Cnv Xiv, the release is permissible. However, if Cnv is within about 10 percent of YZXi,, it I may be impractical to use this value of Cnv. This situation indicates that measured concentrations are approaching values which would cause the limits of Section 3.1.2.a to be exceeded. Therefore, steps should be taken to reduce contributing source terms of gaseous radioactive material, or to adjust the allocation of the limits among the active release points. The setpoint calculations (steps 1-4) must then be repeated with parameters that reflect the modified conditions. If Cnv < Y-Xiv, the release may not be made as planned. Consider the alternatives discussed in the paragraph above, and calculate a new setpoint based on the results of the actions taken.3.3.2.3 Use of the Calculated Setpoint The setpoint calculated above is in the units p.Ci/mL. The monitor actually measures a count rate, subtracts a predetermined background count rate, and multiplies by a calibration factor to convert from count rate to 1 LCi/mL.Initial calibration by the manufacturer and Georgia Power Company of the gaseous effluent monitors specified in Section 3.1.1 utilized at least one NIST-traceable gaseous radionuclide source in the exact geometry of each production monitor. The point and gaseous sources used covered the beta particle end point energy range from 0.293 MeV to at least 1.488 MeV. The calibration factor is a function of the radionuclide mix in the gas to be released, and normally will be calculated for the monitor based on the results of the sample results from the laboratory gamma-ray spectrometer system. The mix-dependent calibration factor will be used as the gain factor in the PERMS monitor, or used to modify the calculated base monitor setpoint so that the default calibration factor in the PERMS monitor can be left unchanged. Notwithstanding the initial calibration, monitor calibration data for conversion between count rate and concentration may include operational data obtained from determining the monitor response to stream concentrations measured by sample analysis.3-25 VER 29 VEGP ODCM In all cases, monitor background must be controlled so that the monitor is capable of responding to concentrations in the range of the setpoint value. Contributions to the monitor background may include any or all of the following factors: ambient background radiation, plant-related radiation levels at the monitor location (which may change between shutdown and power conditions), and internal background due to contamination of the monitor's sample chamber.3.3.3 Setpoints for Noble Gas Monitors on Effluent Source Streams Table 3-4 lists certain gaseous release pathways as being source streams. As may be seen in the figures of Section 3.2, these are streams that merge with other streams, prior to passing a final radioactivity monitor and being released. Unlike the final monitors, the source stream monitors measure radioactivity in effluent streams for which flow can be terminated; therefore, the source stream monitors have control logic to terminate the source stream release at the alarm setpoint.3.3.3.1 Setpoint of the Monitor on the Source Stream Step 1: Determine the concentration XIs of each noble gas radionuclide i in source stream s (in 1.Ci/mL) according to the results of its required sample analyses [see Section 3.1.2].Step 2: Determine rt, the ratio of the dose rate limit for the total body, 500 mrem/y, to the total body dose rate due to noble gases detected in the source stream under consideration. Use the Xis values and the maximum anticipated source stream flowrate fas in equation (3.2) to determine the total body dose rate for the source stream, substituting rt for Rt.The SITE BOUNDARY relative dispersion value used in Steps 2 and 3 for the source stream is the same as the (X--Q)vb that applies to the respective merged stream. This is because the (xlQ) value is determined by the meteorology of the plant site and the physical attributes of the release point, and is unaffected by whether or not a given source stream is operating. Step 3: Determine rk, the ratio of the dose rate limit for the skin, 3000 mrem/y, to the skin dose rate due to noble gases detected in the source stream under consideration. Use the Xis values and the maximum anticipated source stream flow rate fas in equation (3.3) to determine the skin dose rate for the source stream, substituting rk for Rk.Step 4: Determine the maximum noble gas radioactivity monitor setpoint concentration, as follows: 3-26 VER 29 VEGP ODCM{AGs SF -Y Xis" rt Cns = the lesser of (3.5)AGs *SF .Xis.rk where: Cns = the calculated setpoint (in [tCi/mL) for the noble gas monitor serving gaseous source stream s.AGs = the administrative allocation factor applied to gaseous source stream s. For a given final release point v, the sum of all the AGs values for source streams contributing to the final release point must not exceed the release point's allocation factor Agv.Xis = the measured concentration of noble gas radionuclide i in gaseous source stream s, as defined in Step 1, in pCi/mL.The values of rt and rk to be used in the calculation are those which were determined in Steps 2 and 3 above. The safety factor, SF, was defined previously. Step 5: Determine whether the release is permissible, as follows: If Cns > ZXis, the release is permissible. However, if Cns is within about 10 percent of ZX 8 s, it may be impractical to use this value of Cns. This situation indicates that measured concentrations are approaching values which would cause the limits of Section 3.1.2.a to be exceeded. Therefore, steps should be taken to reduce contributing source terms of gaseous radioactive material, or to adjust the allocation of the limits among the active release points. The setpoint calculations (steps 1-4) must then be repeated with parameters that reflect the modified conditions. If Cns < EXis, the release may not be made as planned. Consider the alternatives discussed in the paragraph above, and calculate a new setpoint based on the results of the actions taken.3.3.3.2 Effect on the Setpoint of the Monitor on the Merged Stream Before beginning a release from a monitored source stream, a setpoint must be determined for the source stream monitor as presented in Section 3.3.3.1. In addition, whether or not the source stream has its own effluent monitor, the previously-determined maximum allowable setpoint for the downstream final monitor on the merged stream must be redetermined. This is accomplished by repeating the steps of Section 3.3.2, with the following modifications. 3-27 VER 29 VEGP ODCM Modification 1: The new maximum anticipated flowrate of the merged stream is the sum of the old merged stream maximum flowrate, and the maximum flowrate of the source stream being considered for release.(Janew = (Li. l + fa, (3.6)Modification 2: The new concentration of noble gas radionuclide i in the merged stream includes both the contribution of the merged stream without the source stream, and the source stream being considered for release.tv ' _ (fa, )"/d,, .(X, )o,,, + fas* Xi ,.s -t iv nmew (Jav),ne, t -I 3.3.4 Determination of Allocation Factors, AG When simultaneous gaseous releases are conducted, an administrative allocation factor must be applied to divide the release limit among the active gaseous release pathways.This is to assure that the dose rate limit for areas at and beyond the SITE BOUNDARY (see Section 3.1.2) will not be exceeded by simultaneous releases. The allocation factor for any pathway may be assigned any value between 0 and 1, under the following two conditions:
- 1. The sum of the allocation factors for all simultaneously-active final release paths at the plant site may not exceed 1.2. The sum of the allocation factors for all simultaneously-active source streams merging into a given final release pathway may not exceed the allocation factor of that final release pathway.Any of the following three methods may be used to assign the allocation factors to the active gaseous release pathways: 1. For ease of implementation, AG, may be equal for all release pathways: '1 AG, = -(3.8)where: N = the number of simultaneously active gaseous release pathways.2. AG, for a given release pathway may be selected based on an estimate of the portion of the total SITE BOUNDARY dose rate (from all simultaneous releases)that is contributed by the release pathway. During periods when a given building 3-28 VER 29 VEGP ODCM or release pathway is not subject to gaseous radioactive releases, it may be assigned an allocation factor of zero.3. AG, for a given release pathway may be selected based on a calculation of the portion of the total SITE BOUNDARY dose rate that is contributed by the release pathway, as follows: (XI/Qlb (K Q 1 N)AGv = N (3.9)where: (ROQ)vb = the annual average SITE BOUNDARY relative concentration applicable to the gaseous release pathway v for which the allocation factor is being determined, in s/m 3.Ki = the total-body dose factor due to gamma emissions from noble gas radionuclide i, in (mremly)I( jiCi/m 3), from Table 3-5.QiV = the release rate of noble gas radionuclide i from release pathway v, in ACi/s, calculated as the product of X 1 v and fav, where: Xiv = the concentration of noble gas radionuclide i applicable to the gaseous release pathway v for which the allocation factor is being determined, in ý.Ci/mL.fav = the discharge flowrate applicable to gaseous release pathway v for which the allocation factor is being determined, in mL/s.= the annual average SITE BOUNDARY relative concentration applicable to active gaseous release pathway r, in s/m 3.Qir = the release rate of noble gas radionuclide i applicable to active release pathway r, in ItCi/s, calculated as the product of Xir and far, where: Xir = the concentration of noble gas radionuclide i applicable to active gaseous release pathway r, in pICi/mL.far = the discharge flowrate applicable to active gaseous release pathway r, in mL/s.N = the number of simultaneously active gaseous release pathways (including pathway v that is of interest).
3-29 VER 29 VEGP ODCM NOTE: Although equations (3.8) and (3.9) are written to illustrate the assignment of the allocation factors for final release pathways, they may also be used to assign allocation factors to the source streams that merge into a given final release pathway.3.3.5 Setpoints for Noble Gas Monitors with Special Requirements At present, VEGP has no noble gas monitors for which setpoint methodologies are to be presented in the ODCM, and that require methods other than those in Section 3.3.2 or Section 3.3.3.3.3.6 Setpoints for Particulate and Iodine Monitors In accordance with Section 5.1.1 of NRC NUREG-0133 (Reference 1), the effluent controls of Section 3.1.1 do not require that the ODCM establish setpoint calculation methods for particulate and iodine monitors. Therefore, the following is provided for information only: Initial setpoints for the particulate channels of effluent monitors RE-12442 and RE-2565 were determined as described in Reference 13.3-30 VER 29 VEGP ODCM 3.4 GASEOUS EFFLUENT COMPLIANCE CALCULATIONS 3.4.1 Dose Rates at and Beyond the Site Boundary Because the dose rate limits for areas at and beyond the SITE specified in Section 3.1.2 are site limits applicable at any instant in time, the summations extend over all simultaneously active gaseous final release pathways at the plant site. Table 3-4 identifies the gaseous final release pathways at the plant site, and indicates the (XlQ)Vb value for each.3.4.1.1 Dose Rates Due to Noble Gases For the purpose of implementing the controls of Section 3.1.2.a, the dose rates due to noble gas radionuclides in areas at or beyond the SITE BOUNDARY, due to releases of gaseous effluents, shall be calculated as follows: For total body dose rates: DRt =y_ý(XIQ)Vb, y[KjQij1 (3.10)For skin dose rates: where: DRt = the total body dose rate at the time of the release, in mrem/y.DRk = the skin dose rate at the time of the release, in mrem/y.Qiv = the release rate of noble gas radionuclide i, in ýtCi/s, equal to the product of ft, and Xv, where: fry = the actual average flowrate for release pathway v during the period of the release, in mL/s.All other terms were defined previously. 3.4.1.2 Dose Rates Due to Iodine-1 31, Iodine-1 33, Tritium, and Radionuclides in Particulate Form with Half-Lives Greater than 8 Days For the purpose of implementing the controls of Section 3.1.2.b, the dose rates due to Iodine-1 31, Iodine-1 33, tritium, and all radionuclides in particulate form with half-lives greater than 8 days, in areas at or beyond the SITE BOUNDARY, due to releases of gaseous effluents, shall be calculated as follows: 3-31 VER 29 VEGP ODCM DRVk =(5Y_,b ZVO LY IP Q', i, (3.12)where: DRo = the dose rate to organ o at the time of the release, in mrem/y.Pio = the site-specific dose factor for radionuclide i and organ o, in (mrem/y)/(ýLCi/m 3). Since the dose rate limits specified in Section 3.1.2.b apply only to the child age group exposed to the inhalation pathway, the values of Pi,, may be obtained from Table 3-9, "Raipj for Inhalation Pathway, Child Age Group." Qqv = the release rate of radionuclide i from gaseous release pathway v, in pCi/s. For the purpose of implementing the controls of Section 3.1.2.b, only 1-131, 1-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days should be included in this calculation. All other terms were defined previously.
3.4.2 Noble
Gas Air Dose at or Beyond Site Boundary For the purpose of implementing the controls of Section 3.1.3, air doses in areas at or beyond the SITE BOUNDARY due to releases of noble gases from each unit shall be calculated as follows (adapted from Reference 1, page 28, by including only long-term releases): D,6 = 3.17x 10 {Yiý2Qb Nj .iv (3.13)Dy =3.17x 10{X /Q),Vb [Mi , Qiv (3.14)where: 3.17 x 10-8 = a units conversion factor: 1 y/(3.15 x 10 7 s).Dý = the air dose due to beta emissions from noble gas radionuclides, in mrad.Dy = the air dose due to gamma emissions from noble gas radionuclides, in mrad.Ni = the air dose factor due to beta emissions from noble gas radionuclide i (mrad/y)/(jxCi/m 3), from Table 3-5.3-32 VER 29 VEGP ODCM Mi = the air dose factor due to gamma emissions from noble gas radionuclide i (mrad/y)I(ptCi/m 3), from Table 3-5.Oil = the cumulative release of noble gas radionuclide i from release pathway v (ýiCi), during the period of interest.and all other terms are as defined above.Because the air dose limit is on a per-reactor-unit basis, the summations extend over all gaseous final release pathways for a given unit. For a release pathway discharging materials originating in both reactor units, the activity discharged from the release point may be apportioned to the two units in any reasonable manner, provided that all activity released via the particular shared release pathway is apportioned to one or the other unit.The gaseous final release pathways at the plant site, and the --Q)vb for each, are identified in Table 3-4.3-33 VER 29 VEGP ODCM Table 3-5.Dose Factors for Exposure to a Semi-Infinite Cloud of Noble Gases y -Body (K) 13- Skin (L) 7- Air (M) 3 -Air (N)Nuclide (mrem/y) per (mrem/y) per (mrad/y) per (mrad/y) per (ýtCilm 3) (1 iCilm 3) (gCilm 3) ([LCi/m 3)Kr-83m 7.56 E-02 0.00 E+00 1.93 E+01 2.88 E+02 Kr-85m 1.17 E+03 1.46 E+03 1.23 E+03 1.97 E+03 Kr-85 1.61 E+01 1.34 E+03 1.72 E+01 1.95 E+03 Kr-87 5.92 E+03 9.73 E+03 6.17 E+03 1.03 E+04 Kr-88 1.47 E+04 2.37 E+03 1.52 E+04 2.93 E+03 Kr-89 1.66 E+04 1.01 E+04 1.73 E+04 1.06 E+04 Kr-90 1.56 E+04 7.29 E+03 1.63 E+04 7.83 E+03 Xe-131m 9.15 E+01 4.76 E+02 1.56 E+02 1.11 E+03 Xe-1 33m 2.51 E+02 9.94 E+02 3.27 E+02 1.48 E+03 Xe-133 2.94 E+02 3.06 E+02 3.53 E+02 1.05 E+03 Xe-1 35m 3.12 E+03 7.11 E+02 3.36 E+03 7.39 E+02 Xe-135 1.81 E+03 1.86 E+03 1.92 E+03 2.46 E+03 Xe-137 1.42 E+03 1.22 E+04 1.51 E+03 1.27 E+04 Xe-138 8.83 E+03 4.13 E+03 9.21 E+03 4.75 E+03 Ar-41 8.84 E+03 2.69 E+03 9.30 E+03 3.28 E+03 All values in this table were obtained from Reference 3 (Table B-i), with units converted. 3-34 VER 29 VEGP ODCM Table 3-6.Dose Factors for Exposure to Direct Radiation from Noble Gases in an Elevated Finite Plume The contents of this table are not applicable to VEGP.3-35 VER 29 VEGP ODCM 3-36 VER 29 VEGP ODCM 3.4.3 Dose to a Member of the Public at or Beyond Site Boundary The dose received by an individual due to gaseous releases from each reactor unit, to areas at or beyond the SITE BOUNDARY, depends on the individual's location, age group, and exposure pathways. The MEMBER OF THE PUBLIC expected to receive the highest dose in the plant vicinity is referred to as the controlling receptor. The dosimetrically-significant attributes of the currently-defined controlling receptor are presented in Table 3-7.Doses to a MEMBER OF THE PUBLIC due to gaseous releases of 1-131,1-133, tritium, and all radionuclides in particulate form from each unit shall be calculated as follows (equation adapted from Reference 1, page 29, by considering only long-term releases): Dja = 3.17x 10-" Y{ZiE R [J-W,, [ QKip 1 (3.15)where: Dja = the dose to organ j of an individual in age group a, due to gaseous releases of 1-131, 1-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days, in mrem.3.17 x 10-8 = a units conversion factor: 1 y/(3.15 x 10 7 s).Raipj the site-specific dose factor for age group a, radionuclide i, exposure pathway p, and organ j. For the purpose of implementing the controls of Section 3.1.4, the exposure pathways applicable to calculating the dose to the currently-defined controlling receptor are included in Table 3-7; values of Raipj for each exposure pathway and radionuclide applicable to calculations of dose to the controlling receptor are included in Tables 3-8 through 3-12.A detailed discussion of the methods and parameters used for calculating Raipj for the plant site is presented in Chapter 9. That information may be used for recalculating the Raipj values if the underlying parameters change, or for calculating Raipm values for special radionuclides and age groups when performing the assessments discussed in Section 3.4.4 below.Wvi = the annual average relative dispersion or deposition at the location of the controlling receptor, for release pathway v, as appropriate to exposure pathway p and radionuclide i.3-37 VER 29 VEGP ODCM For all tritium pathways, and for the inhalation of any radionuclide: Wjp is (XIQ),, , the annual average relative dispersion factor for release pathway v, at the location of the controlling receptor (s/m 3).For the ground-plane exposure pathway, and for all ingestion-related pathways for radionuclides other than tritium: Wvip is FJIQ-)vP, the annual average relative deposition factor for release pathway v, at the location of the controlling receptor (m-2). Values of (x-Q)vp and (DI-Q-)vp for use in calculating the dose to the currently-defined controlling receptor are included in Table 3-7.'iv = the cumulative release of radionuclide i from release pathway v, during the period of interest (ptCi). For the purpose of implementing the controls of Section 3.1.4, only 1-131, 1-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days should be included in this calculation. In any dose assessment using the methods of this subsection, only radionuclides detectable above background in their respective samples should be included in the calculation. Because the member of the public dose limit is on a per-unit basis, the summations extend over all gaseous final release pathways for a given unit. For a release pathway discharging materials originating in both reactor units, the activity discharged from the release point may be apportioned between the two units in any reasonable manner, provided that all activity released from the plant site is apportioned to one or the other unit.The gaseous final release pathways at the plant site, and the release elevation for each, are identified in Table 3-4.3-38 VER29 3-38 VER 29 VEGP ODCM Table 3-7.Attributes of the Controlling Receptor The locations of members of the public in the vicinity of the plant site, and the exposure pathways associated with those locations, are determined in the Annual Land Use Census.Dispersion and deposition values were calculated based on site meteorological data collected for the period January 1, 1985 through December 31, 1987.Based on an analysis of this information, the current controlling receptor for the plant site is described as follows.Sector: Distance: Age Group: WSW 1.2 miles Child Exposure Pathways: Inhalation, ground plane, cow meat, and garden vegetation Dispersion Factors (-XIQvb: Ground-Level release points: Mixed-Mode release points: 6.20 E-7 s/m 3 1.27 E-7 s/m 3 Deposition Factors (DI-Qvb: Ground-Level release points: Mixed-Mode release points: 2.80 E-9 m 2 9.90 E-10 m-2 3-39 VER 29 VEGP ODCM 3-40 VER 29 VEGP ODCM 3.4.4 Dose Calculations to Support Other Requirements Case 1: A radiological impact assessment may be required to support evaluation of a reportable event.Dose calculations may be performed using the equations in Section 3.4.3, with the substitution of the dispersion and deposition parameters [(X/Q) and (D/Q)] for the period covered by the report, and using the appropriate pathway dose factors (Raipj) for the receptor of interest. Methods for calculating (X/Q) and (D/Q) from meteorological data are presented in Chapter 8.Values of Raipj other than those presented in Tables 3-8 through 3-12 may need to be calculated. Methods and parameters for calculating values of Raipj are presented in Chapter 9. When calculating Raipo for evaluation of an event, pathway and usage factors specific to the receptor involved in the event may be used in place of the values in Chapter 9, if the specific values are known.Case 2: A dose calculation is required to evaluate the results of the Land Use Census, under the provisions of Section 4.1.2.In the event that the Land Use Census reveals that exposure pathways have changed at previously-identified locations, or if new locations are identified, it may be necessary to calculate doses at two or more locations to determine which should be designated as the controlling receptor. Such dose calculations may be performed using the equations in Section 3.4.3, with the substitution of the annual average dispersion and deposition values [-j-Q-) and (D-I-Q)] for the locations of interest, and using the appropriate pathway dose factors (Raipj) for the receptors of interest.Methods for calculating (X/Q) and (D/Q) from meteorological data are presented in Chapter 8. The values of Raio other than those presented in Tables 3-8 through 3-12 may need to be calculated. Methods and parameters for calculating values of Raipj are presented in Chapter 9.Case 3: Under Section 5.2, a dose calculation may be required to support the determination of a component of the total dose to a receptor other than that currently defined as the controlling receptor.Dose calculations would be performed using the equations in Section 3.4.3, with the dispersion and deposition parameters and appropriate values of (Raipj) for the receptor of interest.Appropriate values of the dispersion and deposition parameters, if not found in Table 3-7, would need to be calculated. Methods for calculating (X/Q) and (D/Q)from meterological data are presented in Chapter 8.3-41 VER 29 VEGP ODCM Appropriate values of Raipj, if not found in Tables 3-8 through 3-12, would need to be calculated. Methods and parameters for calculating values of Raipj are presented in Chapter 9.3-42 VER 29 VEGP ODCM Table 3-8. Raipj for Ground Plane Pathway, All Age Groups Nuclide T. Body Skin H-3 0.00 0.00 C-14 0.00 0.00 P-32 0.00 0.00 Cr-51 4.66E+06 5.51 E+06 Mn-54 1.39E+09 1.63E+09 Fe-55 0.00 0.00 Fe-59 2.73E+08 3.21 E+08 Co-58 3.79E+08 4.44E+08 Co-60 2.15E+10 2.53E+10 Ni-63 0.00 0.00 Zn-65 7.47E+08 8.59E+08 Rb-86 8.99E+06 1.03E+07 Sr-89 2.16E+04 2.51E+04 Sr-90 0.00 0.00 Y-91 1.07E+06 1.21 E+06 Zr-95 2.45E+08 2.84E+08 Nb-95 1.37E+08 1.61 E+08 Ru-103 1.08E+08 1.26E+08 Ru-106 4.22E+08 5.07E+08 Ag-110m 3.44E+09 4.01E+09 Sb-124 5.98E+08 6.90E+08 Sb-125 2.34E+09 2.64E+09 Te-125m 1.55E+06 2.13E+06 Te-127m 9.16E+04 1.08E+05 Te-129m 1.98E+07 2.31E+07 1-131 1.72E+07 2.09E+07 1-133 2.45E+06 2.98E+06 Cs-134 6.86E+09 8.OOE+09 Cs-136 1.51E+08 1.71E+08 Cs-137 1.03E+10 1.20E+10 Ba-140 2.05E+07 2.35E+07 Ce-141 1.37E+07 1.54E+07 Ce-144 6.95E+07 8.04E+07 Pr-143 0.00 0.00 Nd-147 8.39E+06 1.01E+07 1. Units are m 2.(mremlyr)l([tCifs).
- 2. The values in the Total Body column also apply to the Bone, Liver, Thyroid, Kidney, Lung, and GI-LLI organs.3. This table also supports the calculations of section 6.2.3-43 VER 29 VEGP ODCM Table 3-9. Raipj for Inhalation Pathway, Child Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 0.00 1.12E+03 1.12E+03 1.12E+03 1.12E+03 1.12E+03 1.12E+03 C-14 3.59E+04 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 P-32 2.60E+06 1.14E+05 9.88E+04 0.00 0.00 0.00 4.22E+04 Cr-51 0.00 0.00 1.54E+02 8.55E+01 2.43E+01 1.70E+04 1.08E+03 Mn-54 0.00 4.29E+04 9.51E+03 0.00 1.OOE+04 1.58E+06 2.29E+04 Fe-55 4.74E+04 2.52E+04 7.77E+03 0.00 0.00 1.11E+05 2.87E+03 Fe-59 2.07E+04 3.34E+04 1.67E+04 0.00 0.00 1.27E+06 7.07E+04 Co-58 0.00 1.77E+03 3.16E+03 0.00 0.00 1.11E+06 3.44E+04 Co-60 0.00 1.31E+04 2.26E+04 0.00 0.00 7.07E+06 9.62E+04 Ni-63 8.21E+05 4.63E+04 2.80E+04 0.00 0.00 2.75E+05 6.33E+03 Zn-65 4.26E+04 1.13E+05 7.03E+04 0.00 7.14E+04 9.95E+05 1.63E+04 Rb-86 0.00 1.98E+05 1.14E+05 0.00 0.00 0.00 7.99E+03 Sr-89 5.99E+05 0.00 1.72E+04 0.00 0.00 2.16E+06 1.67E+05 Sr-90 1.01E+08 0.00 6.44E+06 0.00 0.00 1.48E+07 3.43E+05 Y-91 9.14E+05 0.00 2.44E+04 0.00 0.00 2.63E+06 1.84E+05 Zr-95 1.90E+05 4.18E+04 3.70E+04 0.00 5.96E+04 2.23E+06 6.11E+04 Nb-95 2.35E+04 9.18E+03 6.55E+03 0.00 8.62E+03 6.14E+05 3.70E+04 Ru-103 2.79E+03 0.00 1.07E+03 0.00 7.03E+03 6.62E+05 4.48E+04 Ru-106 1.36E+05 0.00 1.69E+04 0.00 1.84E+05 1.43E+07 4.29E+05 Ag-110m 1.69E+04 1.14E+04 9.14E+03 0.00 2.12E+04 5.48E+06 1.OOE+05 Sb-124 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Sb-125 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Te-125m 6.73E+03 2.33E+03 9.14E+02 1.92E+03 0.00 4.77E+05 3.38E+04 Te-127m 2.49E+04 8.55E+03 3.02E+03 6.07E+03 6.36E+04 1.48E+06 7.14E+04 Te-129m 1.92E+04 6.85E+03 3.04E+03 6.33E+03 5.03E+04 1.76E+06 1.82E+05 1-131 4.81E+04 4.81E+04 2.73E+04 1.62E+07 7.88E+04 0.00 2.84E+03 1-133 1.66E+04 2.03E+04 7.70E+03 3.85E+06 3.38E+04 0.00 5.48E+03 Cs-134 6.51E+05 1.01E+06 2.25E+05 0.00 3.30E+05 1.21E+05 3.85E+03 Cs-136 6.51E+04 1.71E+05 1.16E+05 0.00 9.55E+04 1.45E+04 4.18E+03 Cs-137 9.07E+05 8.25E+05 1.28E+05 0.00 2.82E+05 1.04E+05 3.62E+03 Ba-140 7.40E+04 6.48E+01 4.33E+03 0.00 2.11E+01 1.74E+06 1.02E+05 Ce-141 3.92E+04 1.95E+04 2.90E+03 0.00 8.55E+03 5.44E+05 5.66E+04 Ce-144 6.77E+06 2.12E+06 3.61E+05 0.00 1.17E+06 1.20E+07 3.89E+05 Pr-143 1.85E+04 5.55E+03 9.14E+02 0.00 3.OOE+03 4.33E+05 9.73E+04 Nd-147 1.08E+04 8.73E+03 6.81E+02 0.00 4.81E+03 3.28E+05 8.21E+04 1.2.Units are (mremlyr)I(p Cilm 3) for all radionuclides.
This table also supports the calculations of section 6.2.3-44 VER 29 VEGP ODCM Table 3-10.Raipj for Inhalation Pathway, Adult Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 0.00 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 C-14 1.82E+04 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 3.41E+03 P-32 1.32E+06 7.71E+04 5.01E+04 0.00 0.00 0.00 8.64E+04 Cr-51 0.00 0.00 1.00E+02 5.95E+01 2.28E+01 1.44E+04 3.32E+03 Mn-54 0.00 3.96E+04 6.30E+03 0.00 9.84E+03 1.40E+06 7.74E+04 Fe-55 2.46E+04 1.70E+04 3.94E+03 0.00 0.00 7.21E+04 6.03E+03 Fe-59 1.18E+04 2.78E+04 1.06E+04 0.00 0.00 1.02E+06 1.88E+05 Co-58 0.00 1.58E+03 2.07E+03 0.00 0.00 9.28E+05 1.06E+05 Co-60 0.00 1.15E+04 1.48E+04 0.00 0.00 5.97E+06 2.85E+05 Ni-63 4.32E+05 3.14E+04 1.45E+04 0.00 0.00 1.78E+05 1.34E+04 Zn-65 3.24E+04 1.03E+05 4.66E+04 0.00 6.90E+04 8.64E+05 5.34E+04 Rb-86 0.00 1.35E+05 5.90E+04 0.00 0.00 0.00 1.66E+04 Sr-89 3.04E+05 0.00 8.72E+03 0.00 0.00 1.40E+06 3.50E+05 Sr-90 9.92E+07 0.00 6.1OE+06 0.00 0.00 9.60E+06 7.22E+05 Y-91 4.62E+05 0.00 1.24E+04 0.00 0.00 1.70E+06 3.85E+05 Zr-95 1.07E+05 3.44E+04 2.33E+04 0.00 5.42E+04 1.77E+06 1.50E+05 Nb-95 1.41E+04 7.82E+03 4.21E+03 0.00 7.74E+03 5.05E+05 1.04E+05 Ru-103 1.53E+03 0.00 6.58E+02 0.00 5.83E+03 5.05E+05 1.10E+05 Ru-106 6.91E+04 0.00 8.72E+03 0.00 1.34E+05 9.36E+06 9.12E+05 Ag-110m 1.08E+04 1.OOE+04 5.94E+03 0.00 1.97E+04 4.63E+06 3.02E+05 Sb-124 3.12E+04 5.89E+02 1.24E+04 7.55E+01 0.00 2.48E+06 4.06E+05 Sb-125 6.61E+04 7.13E+02 1.33E+04 5.87E+01 0.00 2.20E+06 1.01E+05 Te-125m 3.42E+03 1.58E+03 4.67E+02 1.05E+03 1.24E+04 3.14E+05 7.06E+04 Te-127m 1.26E+04 5.77E+03 1.57E+03 3.29E+03 4.58E+04 9.60E+05 1.50E+05 Te-129m 9.76E+03 4.67E+03 1.58E+03 3.44E+03 3.66E+04 1.16E+06 3.83E+05 1-131 2.52E+04 3.58E+04 2.05E+04 1.19E+07 6.13E+04 0.00 6.28E+03 1-133 8.64E+03 1.48E+04 4.52E+03 2.15E+06 2.58E+04 0.00 8.88E+03 Cs-134 3.73E+05 8.48E+05 7.28E+05 0.00 2.87E+05 9.76E+04 1.04E+04 Cs-136 3.90E+04 1.46E+05 1.1OE+05 0.00 8.56E+04 1.20E+04 1.17E+04 Cs-137 4.78E+05 6.21E+05 4.28E+05 0.00 2.22E+05 7.52E+04 8.40E+03 Ba-140 3.90E+04 4.90E+01 2.57E+03 0.00 1.67E+01 1.27E+06 2.18E+05 Ce-141 1.99E+04 1.35E+04 1.53E+03 0.00 6.26E+03 3.62E+05 1.20E+05 Ce-144 3.43E+06 1.43E+06 1.84E+05 0.00 8.48E+05 7.78E+06 8.16E+05 Pr-143 9.36E+03 3.75E+03 4.64E+02 0.00 2.16E+03 2.81E+05 2.OOE+05 Nd-147 5.27E+03 6.1OE+03 3.65E+02 0.00 3.56E+03 2.21E+05 1.73E+05 1. Units are (mremlyr)l(gCilm
- 3) for all radionuclides.
- 2. This table is included to support the calculations of section 6.2.3-45 VER 29 VEGP ODCM Table 3-11. Raipj for Cow Meat Pathway, Child Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 0.00 2.34E+02 2.34E+02 2.34E+02 2.34E+02 2.34E+02 2.34E+02 C-14 5.29E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 P-32 7.41E+09 3.47E+08 2.86E+08 0.00 0.00 0.00 2.05E+08 Cr-51 0.00 0.00 8.79E+03 4.88E+03 1.33E+03 8.91E+03 4.66E+05 Mn-54 0.00 8.01E+06 2.13E+06 0.00 2.25E+06 0.00 6.72E+06 Fe-55 4.57E+08 2.42E+08 7.51E+07 0.00 0.00 1.37E+08 4.49E+07 Fe-59 3.76E+08 6.09E+08 3.03E+08 0.00 0.00 1.77E+08 6.34E+08 Co-58 0.00 1.64E+07 5.02E+07 0.00 0.00 0.00 9.58E+07 Co-60 0.00 6.93E+07 2.04E+08 0.00 0.00 0.00 3.84E+08 Ni-63 2.91E+10 1.56E+09 9.91E+08 0.00 0.00 0.00 1.05E+08 Zn-65 3.75E+08 1.OOE+09 6.22E+08 0.00 6.30E+08 0.00 1.76E+08 Rb-86 0.00 5.77E+08 3.55E+08 0.00 0.00 0.00 3.71E+07 Sr-89 4.82E+08 0.00 1.38E+07 0.00 0.00 0.00 1.87E+07 Sr-90 1.04E+10 0.00 2.64E+09 0.00 0.00 0.00 1.40E+08 Y-91 1.80E+06 0.00 4.82E+04 0.00 0.00 0.00 2.40E+08 Zr-95 2.66E+06 5.85E+05 5.21E+05 0.00 8.38E+05 0.00 6.11E+08 Nb-95 3.1OE+06 1.21E+06 8.62E+05 0.00 1.13E+06 0.00 2.23E+09 Ru-103 1.55E+08 0.00 5.96E+07 0.00 3.90E+08 0.00 4.01E+09 Ru-106 4.44E+09 0.00 5.54E+08 0.00 5.99E+09 0.00 6.90E+10 Ag-110m 8.39E+06 5.67E+06 4.53E+06 0.00 1.06E+07 0.00 6.74E+08 Sb-124 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Sb-125 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Te-125m 5.69E+08 1.54E+08 7.59E+07 1.60E+08 0.00 0.00 5.49E+08 Te-127m 1.77E+09 4.78E+08 2.11E+08 4.24E+08 5.06E+09 0.00 1.44E+09 Te-129m 1.79E+09 5.OOE+08 2.78E+08 5.77E+08 5.26E+09 0.00 2.18E+09 1-131 1.65E+07 1.66E+07 9.46E+06 5.50E+09 2.73E+07 0.00 1.48E+06 1-133 5.67E-01 7.02E-01 2.66E-01 1.30E+02 1.17E+00 0.00 2.83E-01 Cs-134 9.22E+08 1.51E+09 3.19E+08 0.00 4.69E+08 1.68E+08 8.16E+06 Cs-136 1.62E+07 4.46E+07 2.88E+07 0.00 2.37E+07 3.54E+06 1.57E+06 Cs-137 1.33E+09 1.28E+09 1.88E+08 0.00 4.16E+08 1.50E+08 7.99E+06 Ba-140 4.38E+07 3.84E+04 2.56E+06 0.00 1.25E+04 2.29E+04 2.22E+07 Ce-141 2.22E+04 1.11E+04 1.64E+03 0.00 4.86E+03 0.00 1.38E+07 Ce-144 2.32E+06 7.26E+05 1.24E+05 0.00 4.02E+05 0.00 1.89E+08 Pr-143 3.34E+04 1.OOE+04 1.66E+03 0.00 5.43E+03 0.00 3.60E+07 Nd-147 1.17E+04 9.47E+03 7.33E+02 0.00 5.19E+03 0.00 1.50E+07 Units are (mremlyr)l(, Cilm 3) for tritium, and m 2.(mremlyr)I(ý,Cils) for all other radionuclides.
3-46 VER 29 VEGP ODCM Table 3-12. Raipj for Garden Vegetation Pathway, Child Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI H-3 0.00 4.01E+03 4.01E+03 4.01E+03 4.01E+03 4.01E+03 4.01E+03 C-14 8.89E+08 1.78E+08 1.78E+08 1.78E+08 1.78E+08 1.78E+08 1.78E+08 P-32 3.37E+09 1.58E+08 1.30E+08 0.00 0.00 0.00 9.31E+07 Cr-51 0.00 0.00 1.17E+05 6.50E+04 1.78E+04 1.19E+05 6.21E+06 Mn-54 0.00 6.65E+08 1.77E+08 0.00 1.86E+08 0.00 5.58E+08 Fe-55 8.01E+08 4.25E+08 1.32E+08 0.00 0.00 2.40E+08 7.87E+07 Fe-59 3.98E+08 6.43E+08 3.20E+08 0.00 0.00 1.86E+08 6.70E+08 Co-58 0.00 6.44E+07 1.97E+08 0.00 0.00 0.00 3.76E+08 Co-60 0.00 3.78E+08 1.12E+09 0.00 0.00 0.00 2.1OE+09 Ni-63 3.95E+10 2.11E+09 1.34E+09 0.00 0.00 0.00 1.42E+08 Zn-65 8.13E+08 2.16E+09 1.35E+09 0.00 1.36E+09 0.00 3.80E+08 Rb-86 0.00 4.52E+08 2.78E+08 0.00 0.00 0.00 2.91E+07 Sr-89 3.60E+10 0.00 1.03E+09 0.00 0.00 0.00 1.39E+09 Sr-90 1.24E+12 0.00 3.15E+11 0.00 0.00 0.00 1.67E+10 Y-91 1.86E+07 0.00 4.99E+05 0.00 0.00 0.00 2.48E+09 Zr-95 3.86E+06 8.48E+05 7.55E+05 0.00 1.21E+06 0.00 8.85E+08 Nb-95 4.1OE+05 1.60E+05 1.14E+05 0.00 1.50E+05 0.00 2.96E+08 Ru-103 1.53E+07 0.00 5.90E+06 0.00 3.86E+07 0.00 3.97E+08 Ru-106 7.45E+08 0.00 9.30E+07 0.00 1.01E+09 0.00 1.16E+10 Ag-110m 3.21E+07 2.17E+07 1.73E+07 0.00 4.04E+07 0.00 2.58E+09 Sb-124 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Sb-1 25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Te-125m 3.51E+08 9.50E+07 4.67E+07 9.84E+07 0.00 0.00 3.38E+08 Te-127m 1.32E+09 3.56E+08 1.57E+08 3.16E+08 3.77E+09 0.00 1.07E+09 Te-129m 8.41E+08 2.35E+08 1.31E+08 2.71E+08 2.47E+09 0.00 1.03E+09 1-131 1.43E+08 1.44E+08 8.17E+07 4.75E+10 2.36E+08 0.00 1.28E+07 1-133 3.53E+06 4.37E+06 1.65E+06 8.11E+08 7.28E+06 0.00 1.76E+06 Cs-134 1.60E+10 2.63E+10 5.55E+09 0.00 8.15E+09 2.93E+09 1.42E+08 Cs-136 8.24E+07 2.27E+08 1.47E+08 0.00 1.21E+08 1.80E+07 7.96E+06 Cs-137 2.39E+10 2.29E+10 3.38E+09 0.00 7.46E+09 2.68E+09 1.43E+08 Ba-140 2.77E+08 2.42E+05 1.61E+07 0.00 7.89E+04 1.45E+05 1.40E+08 Ce-141 6.56E+05 3.27E+05 4.86E+04 0.00 1.43E+05 0.00 4.08E+08 Ce-144 1.27E+08 3.98E+07 6.78E+06 0.00 2.21E+07 0.00 1.04E+10 Pr-143 1.46E+05 4.37E+04 7.23E+03 0.00 2.37E+04 0.00 1.57E+08 Nd-147 7.15E+04 5.79E+04 4.48E+03 0.00 3.18E+04 0.00 9.17E+07 Units are (mremlyr)I(p.Cilm
- 3) for tritium, and radionuclides.
2 m .(mrem/yr)/(jiCi/s) for all other 3-47 VER29 VEGP ODCM 3.5 GASEOUS EFFLUENT DOSE PROJECTIONS 3.5.1 Thirty-One Day Dose Projections In order to meet the requirements of the limit for operation of the gaseous radwaste treatment system (see Section 3.1.5), dose projections must be made at least once each 31 days; this applies during periods in which a discharge to areas at or beyond the SITE BOUNDARY of gaseous effluents containing radioactive materials occurs or is expected.Projected 31-day air doses and doses to individuals due to gaseous effluents may be determined as follows: For air doses:= 7 Doc x 31+/-+ Dpa (3.16)Dy = ("- x 31 + Dya For individual doses: D=- -D-RZJ 31,+ D (3.17)where: Dpp = the projected air dose due to beta emissions from noble gases, for the next 31 days of gaseous releases.Dpc = the cumulative air dose due to beta emissions from noble gas releases that have occurred in the elapsed portion of the current quarter, plus the release under consideration. DOa = the anticipated air dose due to beta emissions from noble gas releases, contributed by any planned activities during the next 31-day period, if those activities will result in gaseous releases that are in addition to routine gaseous effluents. If only routine gaseous effluents are anticipated, DOa may be set to zero.Dyp = the projected air dose due to gamma emissions from noble gases for the next 31 days of gaseous releases.Dyc = the cumulative air dose due to gamma emissions from noble gas releases that have occurred in the elapsed portion of the current quarter, plus the release under consideration. 3-48 VER 29 VEGP ODCM Dya = the anticipated air dose due to gamma emissions from noble gas releases, contributed by any planned activities during the next 31-day period, if those activities will result in gaseous releases that are in addition to routine gaseous effluents. If only routine gaseous effluents are anticipated, Dya may be set to zero.Dop = the projected dose to the total body or organ o, due to releases of I-131, 1-133, tritium, and particulates for the next 31 days of gaseous releases.Doc = the cumulative dose to the total body or organ o, due to releases of 1-131, 1-133, tritium, and particulates that have occurred in the elapsed portion of the current quarter, plus the release under consideration. Doa = the anticipated dose to the total body or organ o, due to releases of 1-131, 1-133, tritium, and particulates, contributed by any planned activities during the next 31-day period, if those activities will result in gaseous releases that are in addition to routine gaseous effluents. If only routine gaseous effluents are anticipated, Doa may be set to zero.t = the number of whole or partial days elapsed into the current quarter, including the time to the end of the release under consideration (even if the release continues into the next quarter).3.5.2 Dose Projections for Specific Releases Dose projections may be performed for a particular release by performing a pre-release dose calculation assuming that the planned release will proceed as anticipated. For air dose and individual dose projections due to gaseous effluent releases, follow the methodology of Section 3.4, using sample analysis results for the gaseous stream to be released, and parameter values expected to exist during the release period.3-49 VER 29 VEGP ODCM 3.6 DEFINITIONS OF GASEOUS EFFLUENT TERMS Section of Initial Term Definition Use AG = the administrative allocation factor for gaseous streams, applied to divide the gaseous release limit among all the release pathways [unitless]. 3.3.2.1 AGs = the administrative allocation factor for gaseous source stream s, applied to divide the gaseous release limit among all the release pathways [unitless]. 3.3.3 AGv = the administrative allocation factor for gaseous release pathway v, applied to divide the gaseous release limit among all the release pathways [unitless]. 3.3.2.2 c = the setpoint of the radioactivity monitor measuring the concentration of radioactivity in the effluent line prior to release [jiCi/mL]. 3.3.2.1 Cns = the calculated noble gas effluent monitor setpoint for gaseous source stream s [gCi/mL]. 3.3.3 Cnv = the calculated noble gas effluent monitor setpoint for release pathway v [giCi/mL]. 3.3.2.2 Dja = the dose to organ j of an individual in age group a, due to gaseous releases of 1-131, 1-133, tritium, and radionuclides in particulate form with half-lives greater than 3.4.3 8 days [mrem].Doa = the anticipated dose to organ o due to releases of non-noble-gas radionuclides, contributed by any planned activities during the next 31-day period [mrem]. 3.5.1 Do= the cumulative dose to organ o due to releases of non-noble-gas radionuclides that have occurred in the elapsed portion of the current quarter, plus the release under 3.5.1 consideration [mrem].Dop= the projected dose to organ o due to the next 31 days of gaseous releases of non-noble-gas radionuclides [mrem]. 3.5.1 D= the air dose due to beta emissions from noble gas radionuclides [mrad]. 3.4.2 3-50 VER 29 VEGP ODCM Section of Initial Term Definition Use Doa = the anticipated air dose due to beta emissions from noble gas releases, contributed by any planned activities during the next 31-day period [mrad]. 3.5.1 Doc = the cumulative air dose due to beta emissions from noble gas releases that have occurred in the elapsed portion of the current quarter, plus the release under consideration 3.5.1[mrad].DIp = the projected air dose due to beta emissions from noble gases, for the next 31 days of gaseous releases [mrad]. 3.5.1 DY= the air dose due to gamma emissions from noble gas radionuclides [mrad]. 3.4.2 Dya = the anticipated air dose due to gamma emissions from noble gas releases, contributed by any planned activities during the next 31-day period [mrad]. 3.5.1 Dyc = the cumulative air dose due to gamma emissions from noble gas releases that have occurred in the elapsed portion of the current quarter, plus the release under 3.5.1 consideration [mrad].Dyp = the projected air dose due to gamma emissions from noble gases, for the next 31 days of gaseous releases [mrad]. 3.5.1 (DIQ)vp = the annual average relative deposition factor for release pathway v, at the location of the controlling receptor, from 3.4.3 Table 3-7 [m-2].DRk = the skin dose rate at the time of the release [mrem/y]. 3.4.1.1 DRo = the dose rate to organ o at the time of the release 3.4.1.2[mrem/y].DRt = the total body dose rate at the time of the release 3.4.1.1[mrem/y].fav = the maximum anticipated actual discharge flowrate for release pathway v during the period of the planned release 3.3.2.2[mL/s].fas = the maximum anticipated actual discharge flowrate for gaseous source stream s during the period of the planned 3.3.3 3-51 VER 29 VEGP ODCM Section of Initial Term Definition Use release [mL/s].Ki = the total body dose factor due to gamma emissions from noble gas radionuclide i, from Table 3-5 3.3.2.2[(mrem/y)l([.C i/m 3)].Li = the skin dose factor due to beta emissions from noble gas radionuclide i, from Table 3-5 [(mrem/y)/(ý.Cilm 3)]. 3.3.2.2 M= the air dose factor due to gamma emissions from noble gas radionuclide i, from Table 3-5 [(mradly)/(jICi/m 3)]. 3.4.2 N = the number of simultaneously active gaseous release pathways [unitless]. 3.3.4 N = the air dose factor due to beta emissions from noble gas radionuclide i, from Table 3-5 [(mradly)/([iCilm 3)]. 3.4.2 Pio = the site-specific dose factor for radionuclide i (I-131, 1-133, tritium, and radionuclides in particulate form with half-lives greater than 8 days) and organ o. The values of P 0 , are equal to the site-specific Raipj values presented in 3.4.1.2 Table 3-9 [(mrem/y)/(jiCi/m 3)].Q= the release rate of noble gas radionuclide i from release pathway v during the period of interest [pCi/s]. 3.3.2.2 Q'iv= the release rate of radionuclide i (1-131, 1-133, tritium, and radionuclides in particulate form with half-lives greater than 8 days) from gaseous release pathway v during the period of interest [pCi/s]. 3.4.1.2 v= the cumulative release of noble gas radionuclide i from release pathway v during the period of interest [ptCi]. 3.4.2the cumulative release of non-noble-gas radionuclide i from release pathway v, during the period of interest [pCi]. 3.4.3 Raipj = the site-specific dose factor for age group a, radionuclide i, exposure pathway p, and organ j. Values and units of Raipj for each exposure pathway, age group, and radionuclide that may arise in calculations for implementing Section 3.1.4 are listed in Table 3-8 through Table 3-9. 3.4.3 3-52 VER 29 VEGP ODCM Section of Initial Term Definition Use Rk = the ratio of the skin dose rate limit for noble gases, to the skin dose rate due to noble gases in the release under consideration [unitless]. 3.3.2.1 Rt = the ratio of the total body dose rate limit for noble gases, to the total body dose rate due to noble gases in the release under consideration [unitless]. 3.3.2.1 rk = the ratio of the skin dose rate limit for noble gases, to the skin dose rate due to noble gases in the source stream under consideration [unitless]. 3.3.3.1 rt = the ratio of the total body dose rate limit for noble gases, to the total body dose rate due to noble gases in the source stream under consideration [unitless]. 3.3.3.1 SF = the safety factor used in gaseous setpoint calculations to compensate for statistical fluctuations and errors of measurement [unitless]. 3.3.2.2 t =the number of whole or partial days elapsed in the current quarter, including the period of the release under 3.5.1 consideration. Wvip = the annual average relative dispersion [(X-IQ--)P] or deposition [(IQ-)-Pv] at the location of the controlling receptor, for release pathway v, as appropriate to 3.4.3 exposure pathway p and radionuclide i.X = the noble gas concentration for the release under consideration [pCi/mL]. 3.3.2.1 Xir = the concentration of radionuclide i applicable to active gaseous release pathway r [pCi/mL]. 3.3.4 Xis = the measured concentration of radionuclide i in gaseous source stream s [pCi/mL]. 3.3.3 3-53 VER 29 VEGP ODCM Section of Initial Term Definition Use A= the measured concentration of radionuclide i in gaseous stream v [IuCi/mL]. 3.3.2.2 (X/Q) = the highest relative concentration at any point at or beyond the SITE BOUNDARY [s/m 3]. 3.3.2.1 (x-'-IQ),= the annual average SITE BOUNDARY relative concentration applicable to active gaseous release 3.3.4 pathway r [s/m3].= the highest annual average relative concentration at the SITE BOUNDARY for the discharge point of release pathway v, from Table 3-4 [s/m 3]. 3.3.2.2 I-Q-)IP = annual average relative dispersion factor for release pathway v, at the location of the controlling receptor, from 3.4.3 Table 3-7 [s/m 3].3-54 VER 29 VEGP ODCM CHAPTER 4 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM 4.1 LIMITS OF OPERATION The following limits are the same for both units at the site. Thus, a single program including monitoring, land use survey, and quality assurance serves both units.4.1.1 Radiological Environmental Monitoring The Radiological Environmental Monitoring Program (REMP) shall be conducted as specified in Table 4-1.4.1.1.1 Applicability This control applies at all times.4.1.1.2 Actions 4.1.1.2.1 With the REMP not being conducted as specified in Table 4-1, submit to the Nuclear Regulatory Commission (NRC), in the Annual Radiological Environmental Operating Report, a description of the reasons for not conducting the program as required and the plans for preventing a recurrence. Deviations from the required sampling schedule are permitted if specimens are unobtainable due to hazardous conditions, unavailability, inclement weather, equipment malfunction, or other just reasons. If deviations are due to equipment malfunction, efforts shall be made to complete corrective action prior to the end of the next sampling period.4.1.1.2.2 With the confirmed 1 measured level of radioactivity as a result of plant effluents in an environmental sampling medium specified in Table 4-1 exceeding the reporting levels of Table 4-2 when averaged over any calendar quarter, submit within 30 days a special report to the NRC. The special report shall identify the cause(s) for exceeding the limit(s) and define the corrective action(s) to be taken to reduce radioactive effluents so that the potential annual dose to a MEMBER OF THE PUBLIC is less than the calendar year limits of Sections 2.1.3, 3.1.3, and 3.1.4. The methodology and parameters used to estimate the potential annual dose to a MEMBER OF THE PUBLIC shall be indicated in the special report.When more than one of the radionuclides in Table 4-2 are detected in the sampling medium, this report shall be submitted if: Defined as confirmed by reanalysis of the original sample, or analysis of a duplicate or new sample, as appropriate. The results of the confirmatory analysis shall be completed at the earliest time consistent with the analysis.4-1 VER 29 VEGP ODCM concentrat ion (1) concentrat ion (2) + ... > 1.0 reporting level (1) reporting level (2)When radionuclides other than those in Table 4-2 are detected and are the result of plant effluents, this special report shall be submitted if the potential annual dose to a MEMBER OF THE PUBLIC is equal to or greater than the calendar year limits stated in Sections 2.1.3, 3.1.3, and 3.1.4. This special report is not required if the measured level of radioactivity was not the result of plant effluents; however, in such an event, the condition shall be described in the Annual Radiological Environmental Operating Report. The levels of naturally-occurring radionuclides which are not included in the plant's effluent releases need not be reported.4.1.1.2.3 If adequate samples of milk, or during the growing season, grass or leafy vegetation, can no longer be obtained from one or more of the sample locations required by Table 4-1, or if the availability is frequently or persistently wanting, efforts shall be made: to identify specific locations for obtaining suitable replacement samples;and to add any replacement locations to the REMP given in the ODCM within 30 days.The specific locations from which samples became unavailable may be deleted from the REMP. Pursuant to Technical Specification 5.5.1, documentation shall be submitted in the next Radioactive Effluent Release Report for the change(s) in the ODCM, including revised figure(s) and table(s) reflecting the changes to the location(s), with supporting information identifying the cause of the unavailability of samples and justifying the selection of any new location(s). 4.1.1.2.4 This control does not affect shutdown requirements or MODE changes.4.1.1.3 Surveillance Requirements The REMP samples shall be collected pursuant to Table 4-1 from the locations described in Section 4.2, and shall be analyzed pursuant to the requirements of Table 4-1 and Table 4-3. Required detection capabilities for thermoluminescent dosimeters used for environmental measurements shall be in accordance with the recommendations of Regulatory Guide 4.13. Program changes may be initiated based on operational experience. Analyses shall be performed in such a manner that the stated MINIMUM DETECTABLE CONCENTRATIONs (MDCs) will be achieved under routine conditions. Occasionally background fluctuations, unavoidable small sample sizes, the presence of interfering radionuclides, or other uncontrollable circumstances may render these MDCs unachievable. In such cases, the contributing factors will be identified and described in the Annual Radiological Environmental Operating Report.4.1.1.4 Basis 4-2 VER 29 VEGP ODCM The REMP required by this control provides representative measurements of radiation and of radioactive materials in those exposure pathways, and for those radionuclides, which lead to the highest potential radiation exposures of MEMBERS OF THE PUBLIC resulting from the plant operation. The REMP implements Section IV.B.2, Appendix I, 10 CFR 50, and thereby supplements the radiological effluent monitoring program by measuring concentrations of radioactive materials and levels of radiation, which may then be compared with those expected on the basis of the effluent measurements and modeling of the environmental exposure pathways.The detection capabilities required by Table 4-3 are within state-of-the-art for routine environmental measurements in industrial laboratories. 4-3 VER 29 VEGP ODCM Table 4-1. Radiological Environmental Monitoring Program Exposure Number of Representative Samples and Sample Sampling and Type and Pathway Locations(l) Collection Frequency of and/or Sample Frequency Analysis 1. DIRECT RADIATION Direct Thirty-six or more routine monitoring stations, either Quarterly. Gamma dose Radiation(2) with two or more dosimeters, or with one instrument quarterly. for measuring and recording dose rate continuously, placed as follows: An inner ring of stations, one in each meteorological sector in the general area of the site boundary.An outer ring of stations, one in each meteorological sector at approximately 5 miles from the site.The balance of the stations to be placed in special interest areas such as population centers, nearby residences, schools, and in one or more areas to serve as control stations.2. AIRBORNE Radioiodine Samples from 5 or more locations as follows: Continuous Radioiodine and sampler operation Canister: 1-131 Particulates Three or more samples from close to the three site with sample analysis weekly.boundary locations, in different sectors. collection weekly, or more frequently Particulate One sample from the vicinity of a community having if required by dust Sampler: Gross the highest calculated annual average ground-level loading, beta radioactivity D/Q. analysis following filter change, and One sample from a control location, as, for example, gamma isotopic a population center 10 to 20 miles distant and in the analysis of least prevalent wind direction. composite (by location)quarterly.(3)(4) 4-4 VER 29 VEGP ODCM Table 4-1. Radiological Environmental Monitoring Program Exposure Number of Representative Samples Sampling and Collection Type and Frequency of Pathway and Sample Locations(I) Frequency Analysis and/or Sample 3. WATERBORNE Surface(5) One sample upstream. Composite sample over Gamma isotopic analysis 1-month period.(6) monthly; composite for One sample downstream. tritium analysis quarterly.(4) Drinking Two samples at each of the one to Composite sample of river 1-131 analysis on each three nearest water treatment plants water near intake at each sample when the dose that could be affected by discharges water treatment plant over calculated for the from the facility. 2-week period when 1-131 consumption of the water is analysis is performed, greater than 1 mrem per Two samples at a control location, monthly composite year. Composite for gross otherwise; and grab sample beta and gamma isotopic of finished water at each analyses monthly.water treatment plant every Composite for tritium 2 weeks or monthly, as analysis quarterly.(4)(7) appropriate.(6) Sediment from One sample from downstream area Semiannually. Gamma isotopic analysis Shoreline with existing or potential recreational semi-annually.(4) value.Groundwater An adequate number of onsite wells Quarterly Tritium and gamma to provide detection of radioactive isotopic quarterly. Other liquid releases into the groundwater analyses based on results from tanks, underground piping, and of tritium and gamma.other plant equipment. At least one well at a control location.4-5 VER 29 VEGP ODCM Table 4-1. Radiological Environmental Monitoring Program Exposure Number of Representative Samples and Sample Sampling and Type and Pathway Locations(I) Collection Frequency of and/or Sample Frequency Analysis 4. INGESTION Milk Samples from milking animals in three locations within Semimonthly. Gamma 3 miles distance having the highest dose potential; if there isotopic are none, then one sample from milking animals in each of analysis semi-three areas between 3 and 5 miles distance where doses monthly.(4)(8) are calculated to be greater than 1 mrem per year.(7)One sample from milking animals at a control location about 10 miles distant or beyond, and preferably in a wind direction of low prevalence. Fish At least one sample of any commercially and recreationally Semiannually. Gamma important species in vicinity of plant discharge area. isotopic analyses on At least one sample of any species in areas not influenced edible by plant discharge. portions.(4) At least one sample of any anadromous species in vicinity of During spring Gamma plant discharge. spawning isotopic season. analyses on edible portion.(4) Grass or One sample from two onsite locations near the site boundary Monthly during Gamma Leafy in different sectors. growing season. isotopic.(4)(8) Vegetation____________ ____One sample from a control location about 15 miles distant. Monthly during Gamma growing season, isotopic.(4)(8) 4-6 VER 29 VEGP ODCM Table 4-1. Radiological Environmental Monitoring Program TABLE NOTATIONS (1) For each sample location in this table, specific parameters of distance and direction sector from a point midway between the center of the two reactors, and additional description where pertinent, are provided in Table 4-4, and in Figure 4-1 through Figure 4-4 of this ODCM.(2) One or more instruments, such as a pressurized ion chamber, for measuring and recording dose rate continuously, may be used in place of or in addition to integrating dosimeters. For the purpose of this table, a thermoluminescent dosimeter (TLD) is considered to be one phosphor; two or more phosphors in a packet are considered as two or more dosimeters. Film badges shall not be used as dosimeters for measuring direct radiation. (3) Airborne particulate sample filters shall be analyzed for gross beta radioactivity 24 hours or more after sampling to allow for radon and thoron daughter decay. If gross beta activity in air particulate samples is greater than 10 times the yearly mean of control samples, gamma isotopic analysis shall be performed on the individual samples.(4) Gamma isotopic analysis means the identification and quantification of gamma-emitting radionuclides that may be attributable to the effluents from the facility.(5) The upstream sample shall be taken at a distance beyond significant influence of the discharge. The downstream sample shall be taken in an area beyond but near the mixing zone.(6) Composite sample aliquots shall be collected at time intervals that are very short (e.g., hourly) relative to the compositing period (e.g., monthly) in order to assure obtaining a representative sample.(7) The dose shall be calculated for the maximum organ and age group, using the methodology and parameters in the ODCM.(8) If gamma isotopic analysis is not sensitive enough to meet the required MDC for 1-131, a separate analysis for 1-131 will be performed. 4-7 VER 29 VEGP ODCM Table 4-2. Reporting Levels for Radioactivity Concentrations in Environmental Samples Water Airborne Fish Milk Grass or Leafy ApalyLi Particulate or Vegetation ______ Gases (pCi/m 3) (pCi/kg, wet) (pCi/L) (pCi/kg, wet)H-3 2 E+4a Mn-54 1 E+3 3 E+4 Fe-59 4 E+2 1 E+4 Co-58 1 E+3 3 E+4 Co-60 3 E+2 1 E+4 Zn-65 3 E+2 2 E+4 Zr-95 4 E+2 Nb-95 7 E+2 1-131 2 E+Ob 9 E-1 3 E+0 1 E+2 Cs-134 3 E+1 1 E+1 1 E+3 6 E+1 1 E+3 Cs-137 5 E+1 2 E+1 2 E+3 7 E+1 2 E+3 Ba-140 2 E+2 3 E+2 La-140 1 E+2 0 E+2 a. This is the 40 CFR 141 value for drinking water samples. If no drinking water pathway exists, a value of 3 E+04 pCi/L may be used.b. If no drinking water pathway exists, a value of 20 pCi/L may be used.4-8 VER 29 VEGP ODCM Table 4-3. Values for the Minimum Detectable Concentration (MDC)Minimum Detectable Concentration (MDC)a Water Airborne Fish Milk Grass or Leafy Sediment AnlssParticulate or Vegetation Analysis (pCi/L) G ase p r (pCi/kg, wet) (pCi/L) (iget) (pCi/kg, dry)Gases (p Ci/m3) (C(pCi/kg, wet)Gross Beta 4 E+O 1 E-2 H-3 2 E+3b Mn-54 1.5 E+1 1.3 E+2 Fe-59 3 E+1 2.6 E+2 Co-58, Co-60 1.5 E+1 1.3 E+2 Zn-65 3 E+1 2.6 E+2 Zr-95 3 E+1 Nb-95 1.5 E+1 1-131 1 E+Oc 7 E-2 1 E+0 6 E+1 Cs-134 1.5 E+1 5 E-2 1.3 E+2 1.5 E+1 6 E+1 1.5 E+2 Cs-137 1.8 E+1 6 E-2 1.5 E+2 1.8 E+1 8 E+1 1.8 E+2 Ba-140 6 E+1 6 E+1 La-140 1.5 E+1 1.5 E+1 a. See the definition of MINIMUM DETECTABLE CONCENTRATION in Section 10.1. Other peaks which are measurable and identifiable as plant effluents, together with the radionuclides in this table, shall be analyzed and reported in accordance with Section 7.1.b. If no drinking water pathway exists, a value of 3 E+3 pCi/L may be used.c. If no drinking water pathway exists, a value of 1.5 E+1 pCi/L may be used.4-9 VER 29 VEGP ODCM 4.1.2 Land Use Census A land use census shall be conducted and shall identify the following within a distance of 5 miles in each of the 16 meteorological sectors: the location of the nearest milk animal, 1 the nearest permanent residence, and the nearest garden of greater than 500 square feet producing broad leafy vegetation. Land within the Savannah River Site is excluded from this census.4.1.2.1 Applicability This control applies at all times.4.1.2.2 Actions 4.1.2.2.1 With a land use census identifying a location(s) which yields a calculated dose or dose commitment greater than values currently being calculated in accordance with Section 3.4.3, identify the new location(s) in the next Radioactive Effluent Release Report.4.1.2.2.2 With a land use census identifying a location(s) which yields a calculated dose or dose commitment (via the same exposure pathway) 20 percent greater than at a location from which samples are currently being obtained in accordance with Section 4.1.1, add the new location(s) to the REMP within 30 days if samples are available. The sampling location, excluding control station location(s), having the lowest calculated dose or dose commitment (via the same exposure pathway) may be deleted from the REMP if new sampling locations are added. Pursuant to Technical Specification
5.5.1 submit
in the next Radioactive Effluent Release Report any change(s) in the ODCM, including the revised figure(s) and table(s) reflecting any new location(s) and information supporting the change(s). 4.1.2.2.3 This control does not affect shutdown requirements or MODE changes.4.1.2.3 Surveillance Requirements The land use census shall be conducted annually, using that information which will provide good results, such as a door-to-door census, a visual census from automobile or aircraft, consultation with local agriculture authorities, or some combination of these methods, as feasible. Results of the land use census shall be included in the Annual Radiological Environmental Operating Report.4.1.2.4 Basis This control is provided to ensure that changes in the use of UNRESTRICTED AREAS are identified and that modifications to the REMP are made if required by the results of this census. This census satisfies the requirements of Section IV.B.3 of Appendix I to 10 CFR 1 Defined as a cow or goat that is producing milk for human consumption. 4-9 VER 29 VEGP ODCM Part 50. Restricting the census to gardens of greater than 500 ft 2 provides assurance that significant exposure pathways via leafy vegetables will be identified and monitored since a garden of this size is the minimum required to produce the quantity (26 kg/y) of leafy vegetables assumed in Regulatory Guide 1.109 for consumption by a child. To determine this minimum garden size, the following assumptions were made: (1) 20 percent of the garden was used for growing broad leaf vegetation (i.e., similar to lettuce and cabbage) and (2) a vegetation yield of 2 kg/M 2 was obtained.4.1.3 Interlaboratory Comparison Program Analyses shall be performed on radioactive materials supplied as part of an Interlaboratory Comparison Program which satisfies the requirements of Regulatory Guide 4.15, Revision 1, February, 1979.4.1.3.1 Applicability This control applies at all times.4.1.3.2 Actions With analyses not being performed as required by Section 4.1.3, report the corrective actions taken to prevent a recurrence in the Annual Radiological Environmental Operating Report.This control does not affect shutdown requirements or MODE changes.4.1.3.3 Surveillance Requirements A summary of the results obtained as part of the required Interlaboratory Comparison Program shall be included in the Annual Radiological Environmental Operating Report.4.1.3.4 Basis The requirement for participation in an approved Interlaboratory Comparison Program is provided to ensure that independent checks on the precision and accuracy of the measurements of radioactive material in environmental sample matrices are performed as part of the quality assurance program for environmental monitoring, in order to demonstrate that the results are reasonably valid for the purposes of Section IV.B.2, Appendix 1, 10 CFR 50.4-10 VER 29 VEGP ODCM 4.2 RADIOLOGICAL ENVIRONMENTAL MONITORING LOCATIONS Table 4-4 and Table 4-5 and Figure 4-1 through Figure 4-5 specify the locations at which the measurements and samples are taken for the REMP required by Section 4.1.1.4-i 1 VER29 4-11 VER 29 VEGP ODCM Table 4-4. Radiological Environmental Monitoring Locations Location Descriptive Location Direction Distance Sample Number (miles) Type(1)1 River Bank N 1.1 D 2 River Bank NNE 0.8 D 3 Discharge Area NE 0.6 A 3 River Bank NE 0.7 D 4 River Bank ENE 0.8 D 5 River Bank E 1.0 D 6 Plant Wilson ESE 1.1 D 7 Simulator Building SE 1.7 D,V,A 8 River Road SSE 1.1 D 9 River Road S 1.1 D 10 Met Tower SSW 0.9 A 10 River Road SSW 1.1 D 11 River Road SW 1.2 D 12 River Road WSW 1.2 D,A 13 River Road W 1.3 D 14 River Road WNW 1.8 D 15 Hancock Landing Road NW 1.5 D,V 16 Hancock Landing Road NNW 1.4 D,A 17 Savannah River Site, River Road N 5.4 D 18 Savannah River Site, D Area NNE 5.0 D 19 Savannah River Site, Road A.13 NE 4.6 D 20 Savannah River Site, Road A.13.1 ENE 4.8 D 21 Savannah River Site, Road A.17 E 5.3 D 22 River Bank Downstream of Buxton ESE 5.2 D Landing 23 River Road SE 4.6 D 24 Chance Road SSE 4.9 D 25 Chance Road near Highway 23 S 5.2 D 26 Highway 23 and Ebenezer Church SSW 4.6 D Rd.4-12 VER 29 VEGP ODCM Table 4-4 (contd).Radiological Environmental Monitoring Locations Location Descriptive Location Direction Distance Sample Number (miles) Type(l)27 Highway 23, opposite Boll Weevil SW 4.7 D Road 28 Thomas Road WSW 5.0 D 29 Claxton-Lively Road W 5.1 D 30 Nathaniel Howard Road WNW 5.0 D 31 River Road at Allen's Chapel Fork NW 5.0 D 32 River Bank NNW 4.7 D 35 Girard SSE 6.6 D,A 36 GPC Waynesboro Operating WSW 13.9 D,A Headquarters 37 Substation; Waynesboro, GA WSW 16.7 D,V 43 Employees Recreation Area SW 2.2 D 47 Oak Grove Church SE 10.4 D 48 McBean Cemetery NW 10.2 D 51 SGA School; Sardis, GA S 11.0 D 52 Oglethorp Substation; SW 10.7 D Alexander, GA 80 Augusta Water Treatment Plant NNW 29.0 W(2)81 Savannah River N 2.5 F(3),S(4)82 Savannah River (RM 151.2) NNE 0.8 R 83 Savannah River (RM 150.4) ENE 0.8 R, S(4)84 Savannah River (RM 149.5) ESE 1.6 R 85 Savannah River ESE 4.3 F(3)87 Beaufort -Jasper Water Treatment SE 76.0 W(5)Plant; Beaufort, SC 88 Cherokee Hill Water Treatment SSE 72.0 W(6)Plant; Port Wentworth, GA 89 Purrysburg Water Treatment Plant; SSE 76.0 W(7)Purrysburg, SC 101 Girard Dairy S 5.5 M 102 Seven Oaks Dairy w 7.5 M 4-13 VER 29 VEGP ODCM Table 4-4 (cont.) Radiological Environmental Monitoring Locations TABLE NOTATIONS (1) Sample Types: A -Airborne Radioactivity D -Direct Radiation F -Fish M -Milk R -River Water S -River Shoreline Sediment W -Drinking Water (at water treatment plant)V -Vegetation (2) The intake for the Augusta Water Treatment Plant is located on the Augusta Canal. The entrance to this canal is at river mile (RM) 207 on the Savannah River. The canal effectively parallels the river. The intake to the pumping station is about 4 miles down the canal and only 0.1 mile from the river (across land).(3) About a 5-mile stretch of the river is generally needed to obtain adequate fish samples.Samples are normally gathered between RM 153 and 158 for upriver collections and between RMs 144 and 149.4 for downriver collections. (4) Sediment is collected at locations with existing or potential recreational value. High water shifting of the river bottom or other reasons could cause a suitable location for sediment collection to become unavailable or unsuitable. Thus, a stretch of river between RM 148.5 and 150.5 is designated for downriver sediment collections, while a stretch between RM 153 and 154 is designated for upriver collections. In practice, collections are normally made at RM 150.2 for downriver collections and at RM 153.3 for upriver collections. (5) The intake for the Beaufort-Jasper Water Treatment Plant is located at the end of a canal which begins at RM 39.3 on the Savannah River. This intake is about 16 miles by line of sight down the canal from its beginning on the Savannah River.(6) The intake for the Cherokee Hill Water Treatment Plant is located on Abercorn Creek, which is about one and a quarter creek miles from its mouth on the Savannah River at RM 29.(7) The intake for the Purrysburg Water Treatment Plant is located on the same canal as the Beaufort-Jasper Water Treatment Plant. The Purrysburg intake is nearer to the Savannah River at the beginning of the canal.4-14 VER 29 4-14 VFR 29 VEGP ODCM Table 4-5. Groundwater Monitoring Locations WELL AQUIFER MONITORING PURPOSE LT-1 B Water Table NSCW related tank LT-7A Water Table NSCW related tank LT-1 2 Water Table NSCW related tank LT-1 3 Water Table NSCW related tank 802A Water Table Southeastern potential leakage 803A* Water Table Up gradient to rad waste building Down gradient from rad waste bldg and NSCW related facilities 806B Water Table Dilution line 808 Water Table Up gradient; along Pen Branch Fault NSCW related tank; western potential RI Water Tablelekg leakage R2 Water Table Southern potential leakage R3 Water Table Eastern potential leakage R4 Water Table Dilution line R5 Water Table Dilution line R6 Water Table Dilution line R7 Water Table Dilution line R8 Water Table Dilution line 1014 Tertiary Up gradient 1015 Water Table Vertically up gradient 27 Tertiary Down gradient tertiary 29 Tertiary Down gradient tertiary MU-1 Tertiary/Cretaceous Facility water supply River N/A Surface water* May need to be abandoned in the future due to construction activities (REF 23).4-15 VER 29 VEGP ODCM j 4w~91-65,,.) -" 4FA Figure 4-1. Terrestrial Stations Near Site Boundary 4-16 VER29 4-16 VER 29 VEGP ODCM-I .I Figure 4-2. Terrestrial Stations and Aquatic Stations, 0-5 Miles 4-17 VER29 4-17 VER 29 VEGP ODCM Figure 4-3. Terrestrial Stations Beyond 5 Miles 4-18 VER29 4-18 VER 29 VEGP ODCM SO VEGP.Canal to Sup Water to B GEORGIA PURRYSBURG WATER TREATMENT PLANT 0 10 2V 30 CHEROKEE HILL WATER TREATMENT PLANT (PORT WENTWORTH) UTH CAROLINA ply River eaufort Beaufort Jasper County Water Treatment Plant C., V,0 Figure 4-4. Drinking Water Stations 4-19 VER 29 VEGPODCM 11>6'4 5" NEV BARGE rALMJ1 OPTION I 0,. ST DOMRIS BASIN DiAM ,'-..0 OW-1005 179 0 519 27 A\ "9 El Ow-r 0 OW. 1009 m-- p!ont-3 0 0 oO-0C p 1 01t -2 _"--j .520OW W27% I.-t Te~rt~a ocd or mon.Ier.P wi.OV--1 -1012 ULi-2\2' ,V,' V.i L3c L"c. -dc 01cr, 9 ,'- c m o cl 9 1 1 ic'1 4-20 VER 29 VEGPODCM Figure 4-5 Groundwater Monitoring Wells 4-21 VER29 4-21 VER 29 VEGP ODCM CHAPTER 5 TOTAL DOSE DETERMINATIONS
5.1 LIMIT
OF OPERATION In accordance with Technical Specification 5.5.4.j, the dose or dose commitment to any MEMBER OF THE PUBLIC over a calendar year, due to releases of radioactivity and to radiation from uranium fuel cycle sources, shall be limited to less than or equal to 25 mrem to the total body or any organ, except the thyroid, which shall be limited to less than or equal to 75 mrem.5.1.1 Applicability This limit applies at all times.5.1.2 Actions With the calculated doses from the release of radioactive materials in liquid or gaseous effluents exceeding twice the limits of Section 2.1.3, 3.1.3, or 3.1.4, calculations shall be made according to Section 5.2 methods to determine whether the limits of Section 5.1 have been exceeded. If these limits have been exceeded, prepare and submit a special report to the Nuclear Regulatory Commission within 30 days, which defines the corrective actions to be taken to reduce subsequent releases to prevent recurrence of exceeding the limits of Section 5.1 and includes the schedule for achieving conformance with the limits of Section 5.1. This special report, as defined in 10 CFR 20.2203, shall also include an analysis which estimates the radiation exposure (dose) to a MEMBER OF THE PUBLIC from uranium fuel cycle sources (including all effluent pathways and direct radiation) for the calendar year that includes the release(s) covered by this report. This special report shall also describe the levels of radiation and concentrations of radioactive material involved, and the cause of the exposure levels or concentrations. If the estimated dose(s) exceeds the limits of Section 5.1, and if the release condition resulting in violation of the provisions of 40 CFR 190 has not already been corrected, the special report shall include a request for variance in accordance with the provisions of 40 CFR 190 and including the specified information of 40 CFR 190.11 (b). Submittal of the report is considered a timely request, and a variance is granted until staff action on the request is complete.This control does not affect shutdown requirements or MODE changes.5.1.3 Surveillance Requirements Cumulative dose contributions from liquid and gaseous effluents and from direct radiation shall be determined in accordance with Section 5.2. This requirement is applicable only under the conditions set forth above in Section 5.1.2.5.1.4 Basis 5-1 VER 29 VEGP ODCM This control is provided to meet the dose limitations and reporting requirements of 40 CFR 190. The control requires the preparation and submittal of a special report whenever the calculated doses from plant radioactive effluents exceed the limits of Section 5.1. For sites containing up to 4 reactors, it is highly unlikely that the resultant dose to a MEMBER OF THE PUBLIC will exceed the dose limits of 40 CFR 190 if the individual reactors remain within twice the dose design objectives of Appendix I and if direct radiation doses from the units, such as direct exposure from outside storage tanks, are kept small. The special report will describe a course of action which should result in the limitation of dose to a MEMBER OF THE PUBLIC for a calendar year to within the 40 CFR 190 limits. For the purposes of the special report, it may be assumed that the dose commitment to the MEMBER OF THE PUBLIC from other uranium fuel cycle sources is negligible with the exception that dose contributions from other uranium fuel cycle facilities at the same site or within a radius of 5 miles must be considered. If the dose to any MEMBER OF THE PUBLIC is estimated to exceed the requirements of 40 CFR 190, the special report with a request for variance (provided the release conditions resulting in violation of 40 CFR 190 have not already been corrected), in accordance with the provisions of 40 CFR 190.11 and 10 CFR 20.2203(a)(4), is considered to be a timely request and fulfills the requirements of 40 CFR 190 until NRC staff action is completed. The variance only relates to the limits of 40 CFR 190, and does not apply in any way to the requirements for dose limitation as addressed in other sections of this ODCM. An individual is not considered a MEMBER OF THE PUBLIC during any period in which he/she is engaged in carrying out any operation which is part of the nuclear fuel cycle.5-2 VER 29 VEGP ODCM 5.2 DEMONSTRATION OF COMPLIANCE There are no other uranium fuel cycle facilities within 5 miles of the plant site.Therefore, for the purpose of demonstrating compliance with the limits of Section 5.1, the total dose to a MEMBER OF THE PUBLIC in the vicinity of the plant site due to uranium fuel cycle sources shall be determined as follows: DTk = DL + DG +Do + DN (5.1)where: DTk = the total dose or dose commitment to the total body or organ k, in mrem.DL = the dose to the same organ due to radioactivity discharged from the plant site in liquid effluents, calculated in accordance with Section 2.4.1, in mrem.DG = the dose to the same organ due to non-noble-gas radionuclides discharged from the plant site in gaseous effluents, calculated for the controlling receptor in accordance with Section 3.4.3, in mrem.DD = the direct radiation dose to the whole body of an individual at the controlling receptor location, due to radioactive materials retained within the plant site, in mrem. Values of direct radiation dose may be determined by measurement, calculation, or a combination of the two.DN = the external whole body dose to an individual at the controlling receptor location, due to gamma ray emissions from noble gas radionuclides discharged from the plant site in gaseous effluents, in mrem. DN is calculated as follows (equation adapted from Reference 1, page 22, by recasting in cumulative dose form): DN =3.17x1O8Z{X/Q)vp[K.j (5.2)where: 3.17 x 10-8 = a units conversion factor: 1 y/(3.15 x 10 7 s).(iv = the cumulative release of noble gas radionuclide i from release pathway v (pICi), during the period of interest.Ki =the total-body dose factor due to gamma emissions from noble gas radionuclide i (mrem/y)/(ýt Ci/m 3), from Table 3-5.5-3 VER29 5-3 VER 29 VEGP ODCM (XE-Q-)I = annual average relative dispersion factor for release pathway v, at the location of the controlling receptor, from Table 3-7[s/m 3].As defined above, DL and DG are for different age groups, while DD and DN are not age group specific. When a more precise determination of DTk is desired, values of DL and DG may be calculated for all four age groups, and those values used in equation (5.1) to determine age group specific values of DTk; the largest value of DTk for any age group may then be compared to the limits of Section 5.1.5-4 VER 29 VEGP ODCM CHAPTER 6 POTENTIAL DOSES TO MEMBERS OF THE PUBLIC DUE TO THEIR ACTIVITIES INSIDE THE SITE BOUNDARY 6.1 REQUIREMENT FOR CALCULATION To support the reporting requirements of Section 7.2.2.3, an assessment of the radiation doses from radioactive liquid and gaseous effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY shall be performed as specified in Section 6.2, at least once per calendar year.6.2 CALCULATIONAL METHOD For the purpose of performing the calculations required in Section 6.1, the dose to a member of the public inside the SITE BOUNDARY shall be determined at the locations, and for the receptor age groups, defined in Table 6-1. The dose to such a receptor at any one of the defined locations shall be determined as follows: Dik = [DA +DS +DP]'F. (6.1)where: Dik = the total dose to the total body or organ k, in mrem.DA = the dose to the same organ due to inhalation of non-noble-gas radionuclides discharged from the plant site in gaseous effluents, calculated in accordance with Section 3.4.3, in mrem. The FX1Q) value to be used is given for each receptor location in Table 6-1; depleted AM values may be used in calculations for non-noble-gas radionuclides. Ds = the dose to the same organ due to ground plane deposition of non-noble-gas radionuclides discharged from the plant site in gaseous effluents, calculated in accordance with Section 3.4.3, in mrem. The (LjQ) value to be used is given for each receptor location in Table 6-1.Dp = the external whole body dose due to gamma ray emissions from noble gas radionuclides discharged from the plant site in gaseous effluents, calculated using equation (5.2), in mrem. The AM values that are to be used are given for each receptor location in Table 6-1.6-1 VER29 6-1 VER 29 VEGP ODCM Fo = the occupancy factor for the given location, which is the fraction of the year that one individual MEMBER OF THE PUBLIC is assumed to be present at the receptor location [unitless]. Values of Fo for each receptor location are included in Table 6-1.6-2 VER 29 VEGP ODCM Table 6-1. Attributes of Member of the Public Receptor Locations Inside the Site Boundary Location: Visitors Center, SE at 447 meters Age Group: Child Occupancy Factor: 4.57 x 1 0-4 (based on 4 hours per year)Dispersion and Deposition Parameters: Parameter Ground-Level Mixed-Mode Undepleted (57U', s/m 3 5.93 E-6 7.12 E-7 Depleted (X7Q-, s/m 3 5.58 E-6 6.74 E-7 (DM7Q), m 2 2.28 E-8 5.77 E-9 6-3 VER 29 VEGP ODCM CHAPTER 7 REPORTS 7.1 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT 7.1.1 Requirement for Report In accordance with Technical Specification 5.6.2, the Annual Radiological Environmental Operating Report covering the REMP activities during the previous calendar year shall be submitted before May 15 of each year. (A single report fulfills the requirements for both units.) The material provided shall be consistent with the objectives outlined in section 4.1 and section 7.1.2 of the ODCM, and in Sections IV.B.2, IV.B.3, and IV.C of Appendix I to 10 CFR Part 50.7.1.2 Report Contents The materials specified in the following subsections shall be included in each Annual Radiological Environmental Operating Report: 7.1.2.1 Data The report shall include summarized and tabulated results of all REMP samples required by Table 4-1 taken during the report period, in a format similar to that contained in Table 3 of the Radiological Assessment Branch Technical Position (Reference 19); the results for any additional samples shall also be reported. In the event that some results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results; the missing data shall be submitted as soon as possible in a supplementary report. The results for naturally-occurring radionuclides not included in plant effluents need not be reported.7.1.2.2 Evaluations Interpretations and analyses of trends of the results shall be included in the report, including the following: (as appropriate) comparisons with preoperational studies, operational controls, and previous environmental reports; and an assessment of any observed impacts of the plant operation on the environment. If the measured level of radioactivity in an environmental sampling medium exceeding the reporting levels of Table 4-2 is not the result of plant effluents, the condition shall be described as required by Section 4.1.1.2.2. 7.1.2.3 Programmatic Information Also to be included in each report are the following: a summary description of the REMP; a map(s) of all sampling locations keyed to a table giving distances and 7-1 VER 29 VEGP ODCM directions from a point midway between the centers of the two reactors; the results of land use censuses required by Section 4.1.2; and the results of licensee participation in the Interlaboratory Comparison Program required by Section 4.1.3.7.1.2.4 Descriptions of Program Deviations Discussions of deviations from the established program must be included in each report, as follows: 7.1.2.4.1 If the REMP is not conducted as required in Table 4-1, a description of the reasons for not conducting the program as required, and the plans for preventing a recurrence, must be included in the report.7.1.2.4.2 If the MDCs required by Table 4-3 are not achieved, the contributing factors must be identified and described in the report.7.1.2.4.3 If Interlaboratory Comparison Program analyses are not performed as required by Section 4.1.3, the corrective actions taken to prevent a recurrence must be included in the report.7-2 VER 29 VEGP ODCM 7.2 RADIOACTIVE EFFLUENT RELEASE REPORT 7.2.1 Requirement for Report In accordance with Technical Specification 5.6.3, the Radioactive Effluent Release Report covering the operation of the units during the previous calendar year of operation shall be submitted in accordance with 10 CFR Part 50.36a. (A single submittal may be made for Units 1 and 2. However, the submittal shall specify the releases of radioactive material in liquid and gaseous effluents from each unit and solid radioactive waste from the site.) The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the units. The material provided shall be consistent with the objectives outlined throughout this ODCM and the Process Control Program (PCP) and in conformance with 10 CFR Part 50.36a and Section IV.B.1 of Appendix I to 10 CFR Part 50.7.2.2 Report Contents The materials specified in the following subsections shall be included in each Radioactive Effluent Release Report: 7.2.2.1 Quantities of Radioactive Materials Released The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the units as outlined in NRC Regulatory Guide 1.21, "Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," Revision 1, June 1974, with liquid and gaseous effluent data summarized on a quarterly basis and solid radioactive waste data summarized on a semiannual basis following the format of Appendix B thereof. Unplanned releases of radioactive materials in gaseous and liquid effluents from the site to UNRESTRICTED AREAS shall be included in the report, tabulated either by quarter or by event. For gamma emitters released in liquid and gaseous effluents, in addition to the principal gamma emitters for which MDCs are specifically established in Table 2-3 and Table 3-3, other peaks which are measurable and identifiable also shall be identified and reported.7.2.2.2 Meteorological Data The report shall include an annual summary of hourly meteorological data collected over the previous year. This annual summary may be either in the form of an hour-by-hour listing of wind speed, wind direction, and atmospheric stability, and precipitation (if measured) on magnetic tape; or in the form of joint frequency distributions of wind speed, wind direction, and atmospheric stability. In lieu of submission with the Radioactive Effluent Release Report, the licensee has the option of retaining this summary of required meteorological data on site in a file that shall be provided to the NRC upon request.7-3 VER 29 VEGP ODCM 7.2.2.3 Dose Assessments The report shall include an assessment of the radiation doses due to the radioactive liquid and gaseous effluents released from each unit during the previous calendar year.Historical annual average meteorology or the meteorological conditions concurrent with the time of release of radioactive materials in gaseous effluents (as determined by sampling frequency and measurement) shall be used for determining the gaseous pathway doses. This assessment of radiation doses shall be performed in accordance with Sections 2.1.3, 2.4, 3.1.3, 3.1.4, 3.4.2, 3.4.3, 5.1, and 5.2.If a determination is required by Section 5.1.2, the report shall also include an assessment of radiation doses to the likely most exposed MEMBER OF THE PUBLIC from reactor releases and other nearby uranium fuel cycle sources (including doses from primary effluent pathways and direct radiation) for the previous calendar year to show conformance with 40 CFR 190, Environmental Radiation Protection Standards for Nuclear Power Operation; this dose assessment must be performed in accordance with Chapter 5. The report shall also include an assessment of the radiation doses from radioactive liquid and gaseous effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY during the report period; this assessment must be performed in accordance with Chapter 6. All assumptions used in making these assessments (i.e., specific activity, exposure time, and location) shall be included in the report.7.2.2.4 Solid Radwaste Data For each type of solid waste shipped offsite during the report period, the following information shall be included: a. Waste volume, b. Total curie quantity (specify whether determined by measurement of estimate), c. Principal radionuclides (specify whether determined by measurement or estimate), d. Type of waste (e.g., spent resin, compacted dry waste, evaporator bottoms), e. Type of container (e.g., LSA, Type A, Type B, Large Quantity), f. Solidification agent (e.g., cement, urea formaldehyde) and g. Class of solid wastes (as defined by 10 CFR Part 61.)7.2.2.5 Licensee Initiated Document Changes Licensee initiated changes shall be submitted to the Nuclear Regulatory Commission as a part of or concurrent with the Radioactive Effluent Release Report for the period in which any changes were made. Such changes to the ODCM shall be submitted pursuant to Technical Specification 5.5.1. This requirement includes: 7-4 VER 29 VEGP ODCM 7.2.2.5.1 Any changes to the sampling locations in the radiological environmental monitoring program, including any changes made pursuant to Section 4.1.1.2.3. Documentation of changes made pursuant to Section 4.1.1.2.3 shall include supporting information identifying the cause of the unavailability of samples.7.2.2.5.2 Any changes to dose calculation locations or pathways, including any changes made pursuant to Section 4.1.2.2.2. 7.2.2.6 Descriptions of Program Deviations Discussions of deviations from the established program shall be included in each report, as follows: 7.2.2.6.1 The report shall include deviations from the liquid and gaseous effluent monitoring instrumentation operability requirements included in Sections 2.1.1 and 3.1.1, respectively. The report shall include an explanation as to why the inoperability of the liquid or gaseous effluent monitoring instrumentation was not corrected within the specified time requirement. 7.2.2.6.2 The report shall include a description of the events leading to liquid holdup tanks or gas storage tanks exceeding the limits of Technical Specification 5.5.12.7.2.2.7 Major Changes to Radioactive Waste Treatment Systems As required by Sections 2.1.5 and 3.1.6, licensee initiated MAJOR CHANGES TO RADIOACTIVE WASTE TREATMENT SYSTEMS (liquid and gaseous) shall be reported to the Nuclear Regulatory Commission in the Radioactive Effluent Release Report covering the period in which the change was reviewed and accepted for implementation. 1 The discussion of each change shall contain: a. A summary of the evaluation that led to the determination that the change could be made in accordance with 10 CFR 50.59;b. Sufficient detailed information to totally support the reason for the change without benefit of additional supplemental information;
- c. A detailed description of the equipment, components, and processes involved and the interfaces with other plant systems;In lieu of inclusion in the Radioactive Effluents Release Report, this same information may be submitted as part of the annual FSAR update.7-5 VER 29 VEGP ODCM d. An evaluation of the change which shows the predicted releases of radioactive materials in liquid and gaseous effluents that differ from those previously predicted in the license applications and amendments thereto;e. An evaluation of the change which shows the expected maximum exposures to individuals in the UNRESTRICTED AREA and to the general population that differ from those previously estimated in the license applications and amendments thereto;f. A comparison of the predicted releases of radioactive materials, in liquid and gaseous effluents, to the actual releases for the period prior to when the changes are to be made;g. An estimate of the exposure to plant operating personnel as a result of the change; and h. Documentation of the fact that the change was reviewed and found acceptable by the PRB.7-6 VER 29 VEGP ODCM 7.3 MONTHLY OPERATING REPORT This ODCM establishes no requirements pertaining to the Monthly Operating Report.7.4 SPECIAL REPORTS Special reports shall be submitted to the Nuclear Regulatory Commission as required by Sections 2.1.3.2, 2.1.4.2, 3.1.3.2, 3.1.4.2, 3.1.5.2, 4.1.1.2.2, and 5.1.2.7-7 VER 29 VEGP ODCM CHAPTER 8 METEOROLOGICAL MODELS The models presented in this chapter are those which were used to compute the specific values of meteorology-related parameters that are referenced throughout this ODCM. These models should also be used whenever it is necessary to calculate values of these parameters for new locations of interest.Note: Although Plant Vogtle has no pure elevated releases, the sections on elevated-mode calculations (8.1.2 and 8.2.2) are included for convenience in calculating mixed-mode values, and to preserve section number compatibility with the ODCMs of the other Southern Company nuclear power plants.8.1 ATMOSPHERIC DISPERSION Atmospheric dispersion may be calculated using the appropriate form of the sector-averaged Gaussian model. Gaseous release elevations may be considered to be either at ground-level, elevated, or mixed-mode.
Facility release elevations for each gaseous release point are as indicated in Table 3-4.8.1.1 Ground-Level Releases Relative concentration calculations for ground-level releases, or for the ground-level portion of mixed-mode releases, shall be made as follows: (X/Q)-= 2.O325-K, rE nk (8.1)N r Xjk IUj Y where: (X/Q)G = the ground-level sector-averaged relative concentration for a given wind direction (sector) and distance (s/mi 3).2.032 = (2/h)1 1 2 divided by the width in radians of a 22.50 sector, which is 0.3927 radians.8 = the plume depletion factor for all radionuclides other than noble gases at a distance r shown in Figure 8-3. For noble gases, the depletion factor is unity. If an undepleted relative concentration is desired, the depletion factor is unity. Only depletion by deposition is considered since depletion by radioactive decay would be of little significance at the distances considered. Kr = the terrain recirculation factor corresponding to a distance r, taken from Appendix A of Reference 15.8-1 VER 29 VEGP ODCM njk = the number of hours that wind of wind speed class j is directed into the given sector during the time atmospheric stability category k existed.N = the total hours of valid meteorological data recorded throughout the period of interest for all sectors, wind speed classes, and stability categories. u= the wind speed (mid-point of wind speed class j) at ground level (m/s).r = the distance from release point to location of interest (m).Lzk = the vertical standard deviation of the plume concentration distribution considering the initial dispersion within the building wake, calculated as follows: zk ,.YZzk = the lesser q OR (8.2)ORF3(azk=zk the vertical standard deviation of the plume concentration distribution (m)for a given distance and stability category k as shown in Figure 8-1. The stability category is determined by the vertical temperature gradient AT/Az (0C/100 m).r = 3.1416 b = the maximum height of adjacent plant structure (55 m).8.1.2 Elevated Releases Relative dispersion calculations for elevated releases, or for the elevated portion of mixed-mode releases, shall be made as follows: (X/Q)E _ 2.032KY ,k ujk _(N rO (8.3)8-2 VER 29 VEGP ODCM where: (X/Q)E = the elevated release sector-averaged relative concentration for a given wind direction (sector) and distance (s/m 3).8k= the plume depletion factor for all radionuclides other than noble gases at a distance r for elevated releases, as shown in Figure 8-4, Figure 8-5, and Figure 8-6. For an elevated release, this factor is stability dependent. For noble gases, the depletion factor is unity. If an undepleted relative concentration is desired, the depletion factor is unity.Only depletion by deposition is considered since depletion by radioactive decay would be of little significance at the distances considered. njk = the number of hours that wind of wind speed class j is directed into the given sector during the time atmospheric stability category k existed.uj= the wind speed (mid-point of wind speed class j) at the effective release height h (m/s).h = the effective height of the release (m), which is calculated as follows: h = h,, + hpr -h, -c,. (8.4)hv= the height of the release point (m).ht= the maximum terrain height between the release point and the point of interest (m), from Table 8-1.hpr = the additional height due to plume rise (m) which is calculated as follows and limited by hpr(max): 1," 2/3 I/hPr=14 4c{UJ diI/ (8.5)((w'31 -Jd SU )hpr(max)= the lesser of: OR (8.6)ofj5O.R,- -I/6 d = the inside diameter of the vent (m).8-3 VER 29 VEGP ODCM Cv= the correction for low vent exit velocity (m), which is calculated as follows: 311.5W- 1.d for-W° <1.5 CV OR (8.7)cv={ u)for Wo 1. 5 U Fm = the momentum flux parameter (m 4/s 2), which is calculated as follows: Fm =WO ).d 2 (8.8)S 2)S = the stability parameter: = 8.75 x 10-4s-2 for -0.5 < AT < 1.5= 1.75 x 10-3 s-2 for 1.5 < AT < 4.0= 2.45 x 10-3 s-2 for AT > 4.0 All other symbols are as previously defined in Section 8.1.1.8.1.3 Mixed-Mode Releases Relative dispersion calculations for mixed-mode releases shall be made as follows: (X/Q)A, = (I -E) .(X/Q)E + E .(X/Q)G (8.9)where: (X/Q)M = the mixed-mode release sector-averaged relative concentration for a given wind direction (sector) and distance (s/mi 3).E = the fraction of hours during which releases are considered as ground-level releases, calculated as follows: 8-4 VER 29 VEGP ODCM 1.0 for W <1.0 uj 0.3-0.06. w wo 5.0 for 1.5<) u 0 for W0 > 5.0 Uj All other symbols are as previously defined.8-5 VER 29 VEGP ODCM 8.2 RELATIVE DEPOSITION Plume depletion may be calculated using the appropriate form of the sector-averaged Gaussian model. Gaseous release elevations may be considered to be either at ground-level, elevated, or mixed-mode. Facility release elevations for each gaseous release points are as indicated in Table 3-4.8.2.1 Ground-Level Releases Relative deposition calculations for ground-level releases, or for the ground-level portion of mixed-mode releases, shall be made as follows: (DQ) = 2.55D, K Nr k where: (D/Q)G = the ground-level sector-averaged relative deposition for a given wind direction (sector) and distance (m-2).2.55 = the inverse of the number of radians in a 22.5' sector [= (2 7T /16)-1].Dg = the deposition rate at distance r, taken from Figure 8-7 for ground-level releases (m-1).nk= the number of hours in which the wind is directed into the sector of interest, and during which stability category k exists.All other symbols are as defined previously in Section 8.1.8.2.2 Elevated Releases Relative deposition calculations for elevated releases, or for the elevated portion of mixed-mode releases, shall be made as follows: (D/Q)F = 2.55K, Z (n1 Dk (8.12)Nr k where: (D/Q)E = the elevated-plume sector-averaged relative deposition for a given wind direction (sector) and distance (m-2).Dek = the elevated plume deposition rate at distance r, taken from Figure 8-8, Figure 8-9, or Figure 8-10, as appropriate to the plume effective release height h defined in Section 8.1.2, for stability class k (m-1).All other symbols are as defined previously. 8-6 VER 29 VEGP ODCM 8.2.3 Mixed-Mode Releases Relative deposition calculations for mixed-mode releases shall be made as follows: (D/Q)0 = (1- E).(D/Q)E + E.(D/Q)G (8.13)where: (D/Q)M = the mixed-mode release sector-averaged relative deposition for a given wind direction (sector) and distance (m-2).E = the fraction of hours during which releases are considered as ground-level releases, defined in Section 8.1.3.All other symbols are as previously defined.8.3 ELEVATED PLUME DOSE FACTORS These factors are not required in effluent dose calculations for VEGP.8-7 VER 29 VEGP ODCM Table 8-1. Terrain Elevation Above Plant Site Grade Dist. NENNESNE ENE EWESE TSW W SNSSWW NNW (m) 1 500 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 8.7 5.7 1.4 5.8 5.7 3.5 1,000 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 16.7 13.4 3.3 10.4 11.8 6.8 1,500 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 21.7 18.6 7.3 12.2 14.3 7.3 2,000 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 21.7 18.6 7.3 12.2 14.3 7.3 2,500 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 21.7 18.6 7.3 12.2 14.3 7.3 3,000 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 23.7 18.6 7.3 12.2 14.3 7.3 3,500 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4.7 24.4 18.6 7.3 12.2 16.9 7.3 4,000 0.0 0.0 0.0 0.0 0.0 0.0 4.5 0.0 0.0 4.7 24.4 18.6 7.3 12.2 16.9 7.3 5,000 0.0 0.0 0.0 0.0 0.0 0.0 11.1 0.0 0.0 4.7 24.7 18.6 7.3 12.2 16.9 7.3 6,000 0.0 0.0 0.0 0.0 0.0 0.0 11.1 0.0 0.0 4.7 26.8 18.6 7.3 12.2 16.9 7.3 7,000 0.0 0.0 0.0 7.8 0.0 0.0 11.1 0.0 3.6 4.7 26.8 18.6 7.3 12.2 16.9 7.3 8,000 0.0 0.0 21.1 13.9 0.0 0.0 11.8 0.0 14.6 4.7 26.8 18.6 7.3 12.2 16.9 7.3 9,000 0.0 0.0 24.4 14.6 0.0 0.0 12.7 7.1 14.6 5.1 26.8 18.6 7.3 12.2 16.9 7.3 10,000 0.0 10.2 24.4 20.2 0.0 0.0 17.1 17.0 14.6 6.8 26.8 18.6 7.3 12.2 16.9 7.3 12,000 0.0 15.9 26.8 20.2 0.0 0.0 17.1 19.5 14.6 6.8 34.1 28.9 13.4 12.2 16.9 7.3 14,000 0.0 15.9 26.8 20.2 0.0 0.0 17.1 19.5 14.6 6.8 34.1 28.9 13.4 16.5 19.7 7.3 16,000 0.0 15.9 26.8 21.7 13.2 0.0 17.1 19.5 14.6 6.8 34.1 28.9 13.4 16.5 25.7 7.3 Data in this table are obtained from Reference 11.8-8 VER 29 VEGPODCM I UI.: ".'.-f--' I A' I I I I-1, N 0 V -/0CI I-01 E "1-01 L., 00 1 40 10'0 0.1 1 10 PLUME TRAVEL DISTANCE (KILOMETERS) 100 Range of Vertical Range of Vertical Category Temperature Gradient Temperature Gradient (0 C/100 m) (°F/100 ft)A AT/AZ < -1.9 AT/AZ < -1.0 B -1.9 s AT/AZ < -1.7 -1.0 s AT/AZ < -0.9 C -1.7 s AT/AZ < -1.5 -0.9 s AT/AZ < -0.8 D -1.5 s AT/AZ < -0.5 -0.8 s AT/AZ < -0.3 E -0.5 s AT/AZ < 1.5 -0.3 s AT/AZ < 0.8 F 1.5 s AT/AZ < 4.0 0.8 s AT/AZ < 2.2 G 4.0 s AT/AZ 2.2 s AT/AZ mTh caranh is reproduced from Reference 5 (Figure 1)5 Figure 8-1. Vertical Standard Deviation of Material in a Plume (crz)8-9 VER 29 VEGP ODCM 8-10 VER 29 VEGP ODCM This figure intentionally left blank.Refer to the definition for Kr (terrain recirculation factor) in section 8.1.1 for applicable plant data.Figure 8-2. Terrain Recirculation Factor (Kr)8-11 VER 29 VEGPODCM z w 6 t=a: 1.0 0.9 0.7 0.6 0.4 0.2 0.1 0.1 1.0 1 0 PLUME TRAVEL DISTANCE (KILOMETERS) 100.0 200.0 This graph is reproduced from Reference 5 (Figure 2).Figure 8-3. Plume Depletion Effect for Ground Level Releases 8-12 VER 29 VEGPODCM 1.0 0.1I£0.7 I ,o, c 0.1 0.4 C U. 0".3 0.2 0.1 0.1 1.0 10.0 PLUMETRAVEL DISTANCE (KILOMETERS) 100.0' IOQ.0 This graph is reproduced from Reference 5 {Figure 3)Fiaure 8-4. Plume Depletion Effect for 30-Meter Releases 8-13 VER 29 VEGPODCM 1.0 0.8 r-: -::: 1:..STABLE-r-t-- J -ý EUTR.A.L'0.8'g- 0.7 z o.e 0.20.3 0.1 1.0 10.0 PLUMETRAVEL DISTANCE (KILOMETERSJ This graph is reproduced from Reference 5 (Figure 4).8-14 VER 29 VEGPODCM 100.0 200.0 Figure 8-5. Plume Depletion Effect for 60-Meter Releases 8-15 VER 29 VEGPODCM 1.0 S.,-I iV 0.8 0.7 i Z 0.1 C It 0.5 Q= OA ac 0.3--o-0 NEUTRAL CDJ _UNSTABLE STABLE CE.F,G) lA.B.C)IR L I I. ) I I (FRACTI{N -EIIJN i 1.f i L I,,I G.2 0.1 0.1 1.0 10.0 PLUME.TRAVEL DISTANCE CKILOMETERSJ 100.0 200.0 This graph is reproduced from Reference 5 (Figure 5).8-16 VER 29 VEGPODCM---I ~-*r--~I I I lo-w a: w!: V-- u I II I l III a: zo to-ill A.W C w a: Io-7 0.1 1.0 10.0 PLUME TRAVEL DISTANCE (KILOMETERS) 100.0 200.0 This graph is reproduced from Reference 5 (Figure 6)Figure 8-6. Plume Depletion Effect for 100-Meter Releases 8-17 VER 29 VEGP ODCM Figure 8-7. Relative Deposition for Ground-Level Releases 8-18 VER 29 VEGPODCM 1o-4 " t' I I I 11 ic -j IH' I ... I I I :E a: '"' I NEUTRAL z NEUTRALUME thi g a-5 is rc 7..en 8 e D I fr0MeR 0 ' i i: a: JrAL(EFG 10-6 -" l I I : :: :F: 0.1 1.0 10.0 100.0 200.0 PLUME TRAVEL DISTANCE (KILOM4ETERS) This graph is reproduced from Reference 5 (Figure 7).Figure 8-8. Relative Deposition for 30-Meter Releases 8-19 VER 29 VEGPODCM Io-5 w w a::.w a: z Io-6 Io-7.,STABLE EFG i! I FL J I 0.1 1.0 I0.Ot 100.0- 200.0 PLUME TRAVEL DISTANCE (KILOMETERS) This graph is reproduced from Reference 5 [Figure 8).8-20 VER 29 VEGPODCM I-igure b-9. Relative IUeposition tor (bu-Meter Releases 8-21 VER 29 VEGPODCM 10 lo-s%V a: C(z III i--w C w a: 10-6 III UNSTABLE (A,B C1 if w STABLE (E,FG)PLUME TRAVEL DISTANCE (KILOMETERS) 10-8 This graph is reproduced from Reference 5 (Figure 9).Figure 8-10. Relative Deposition for 100-Meter (or Greater) Releases 8-22 VER 29 VEGP ODCM CHAPTER 9 METHODS AND PARAMETERS FOR CALCULATION OF GASEOUS EFFLUENT PATHWAY DOSE FACTORS, Raipj 9.1 INHALATION PATHWAY FACTOR For the inhalation pathway, Raipj in (mrem/y) per ( iCi/m 3) is calculated as follows (Reference 1, Section 5.3.1.1): Raipj = K 1 * (BR)a .(DFA)a~j (9.1)where: K 1 = the units conversion factor: 106 pCi/ltCi.(BR)a = the breathing rate of receptor age group a, in m 3/y, from Table 9-5.(DFA)aij = the inhalation dose factor for receptor age group a, radionuclide i, and organ j, in mrem/pCi, from Table 9-7 through Table 9-10.9-1 VER 29 VEGP ODCM 9.2 GROUND PLANE PATHWAY FACTOR For the ground plane external exposure pathway, Raipj in (m 2.mrem/y) per (ýtCi/s)is calculated as follows (Reference 1, Section 5.3.1.2): Rapj= K, .-K2 .(SHF). (DFG j1-e') (9.2)where: K 1 = the units conversion factor: 106 pCi/pCi.K 2 = the units conversion factor: 8760 h/y.(SHF) = the shielding factor due to structure (dimensionless). The value used for (SHF) is 0.7, from (Reference 3, Table E-15).(DFG)ij = the ground plane dose factor for radionuclide i and organ j, in (mrem/h) per (pCi/m 2), from Table 9-15. Dose factors are the same for all age groups, and those for the total body also apply to all organs other than skin.= the radioactive decay constant for radionuclide i, in s-1. Values of Xi used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.t = the exposure time, in s. The value used fort is 4.73 x 10 8 s (= 15 y), from (Reference 1, Section 5.3.1.2).9-2 VER 29 VEGP ODCM 9.3 GARDEN VEGETATION PATHWAY FACTOR For radionuclides other than tritium in the garden vegetation consumption pathway, Rapj in (m 2.mrem/y) per (pICi/s) is calculated as follows (Reference 1, Section 5.3.1.5): R,,,pj = K, .MA (DFLT),, (UfLe-' + e (9.3)where: K 1 = the units conversion factor: 106 pCi/lCi.r = the fraction of deposited activity retained on the edible parts of garden vegetation (dimensionless). The value used for r is 1.0 for radioiodines and 0.2 for particulates, from (Reference 3, Table E-1).Yv the areal density (agricultural productivity) of growing leafy garden vegetation, in kg/M 2 , from Table 9-1.= the radioactive decay constant for radionuclide i, in s-1. Values of Xq used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.x = the rate constant for removal of activity on leaf and plant surfaces by weathering, in s-1, from Table 9-1.(DFL)aij -the ingestion dose factor for receptor age group a, radionuclide i, and organ j, in mrem/pCi, from Table 9-11 through Table 9-14.UaL the consumption rate of fresh leafy garden vegetation by a receptor in age group a, in kg/y, from Table 9-5.Uas = the consumption rate of stored garden vegetation by a receptor in age group a, in kg/y, from Table 9-5.fL = the fraction of the annual intake of fresh leafy garden vegetation that is grown locally (dimensionless), from Table 9-1.fg = the fraction of the annual intake of stored garden vegetation that is grown locally (dimensionless), from Table 9-1.tL = the average time between harvest of fresh leafy garden 9-3 VER 29 VEGP ODCM vegetation and its consumption, in s, from Table 9-1.thv = the average time between harvest of stored garden vegetation and its consumption, in s, from Table 9-1.For tritium in the garden vegetation consumption pathway, Raipj in (mrem/y) per (pLCi/i 3) is calculated as follows (Reference 1, Section 5.3.1.5), based on the concentration in air rather than deposition onto the ground: (0.5,)Ra,rj = K, .K 3* (DFL),I -*(U,.flI + Uasf, )O. 75. -- 1 (9.4)~H where: K 3 = = the units conversion factor: 10 3 g/kg.H = = the absolute humidity of atmospheric air, in g/m 3 , from Table 9-1.0.75 = the fraction of the mass of total garden vegetation that is water= (dimensionless). 0.5 = = the ratio of the specific activity of tritium in garden vegetation water to that in atmospheric water (dimensionless). and other parameters are as defined above.9-4 VER 29 VEGP ODCM Table 9-1.Miscellaneous Parameters for the Garden Vegetation Pathway The following parameter values are for use in calculating Raipj for the garden vegetation pathway only. The terms themselves are defined in section 9.3.Parameter Value Reference Yv 2.0 kg/M 2 Ref. 3, Table E-15 Xw 5.73 x 10-7s 1 Ref. 1, page 33 (14-day half-life) fL 1.0 Ref. 1, page 36 f9 0.76 Ref. 1, page 33 tL 8.6 x 104S Ref. 3, Table E-15 (1 day)thy 5.18 x 106 S Ref. 3, Table E-15 (60 days)H 8 g/m 3 Ref. 3 9-5 VER 29 VEGP ODCM 9.4 GRASS-COW-MILK PATHWAY FACTOR For radionuclides other than tritium in the grass-cow-milk pathway, Raipj in (m 2.mrem/y) per (gCi/s) is calculated as follows (Reference 1, Section 5.3.1.3): R,,,m = K, r .Q p. .U,,p .F,,, .(DFL),,,j .ýfpf, + (I*fm -' (9.6)Y Y (+) ., where: K 1 = the units conversion factor: 106 pCi/gCi.r = the fraction of deposited activity retained on the edible parts of vegetation (dimensionless). The value used for r is 1.0 for radioiodines and 0.2 for particulates, from (Reference 3, Table E-1).x = the radioactive decay constant for radionuclide i, in s-1. Values of Xj used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.w = the rate constant for removal of activity on leaf and plant surfaces by weathering, in s-1, from Table 9-2.QF = the cow's consumption rate of feed, in kg/d, from Table 9-2.Uap the consumption rate of cow milk by a receptor in age group a, in L/y, from Table 9-5.Fmi the stable element transfer coefficient applicable to radionuclide i, for cow's milk, in d/L, from Table 9-6.(DFL)aij = the ingestion dose factor for receptor age group a, radionuclide i, and organ j, in mrem/pCi, from Table 9-11 through Table 9-14.fp the fraction of the year that the cow is on pasture (dimensionless), from Table 9-2.fs the fraction of the cow's feed that is pasture grass while the cow is on pasture (dimensionless), from Table 9-2.Y1 = the areal density (agricultural productivity) of growing pasture feed grass, in kg/mi, from Table 9-2.9-6 VER 29 VEGP ODCM Y = the areal density (agricultural productivity) of growing stored feed, in kg/M 2 , from Table 9-2.thin = the transport time from harvest of stored feed to its consumption by the cow, in s, from Table 9-2.tf = the transport time from consumption of feed by the cow, to consumption of milk by the receptor, in s, from Table 9-2.For tritium in the grass-cow-milk pathway, Raipj in (mrem/y) per (ltCi/m 3) is calculated as follows (Reference 1, Section 5.3.1.5), based on the concentration in air rather than deposition onto the ground: R,,Pi=K, K 3 .QF .Up ' F,, .(DFL)ao .0. 75.1 (05) (9.6)where: K3 = the units conversion factor: 103 g/kg.H = the absolute humidity of atmospheric air, in g/m 3 , from Table 9-2.0.75 = the fraction of the mass of total vegetation that is water (dimensionless). 0.5 = the ratio of the specific activity of tritium in vegetation water to that in atmospheric water (dimensionless). and other parameters are as defined above.9-7 VER 29 VEGP ODCM Table 9-2.Miscellaneous Parameters for the Grass-Cow-Milk Pathway The following parameter values are for use in calculating only. The terms themselves are defined in section 9.4.Raipj for the grass-cow-milk pathway Parameter Value Reference 5.73 x 10-7 s-1 Ref. 1, page 33 (14-day half-life) QF 50 kg/d Ref. 3, Table E-3 fp 1.0 Ref. 1, page 33 fs 1.0 Ref. 1, page 33 YP 0.7 kg/M 2 Ref. 3, Table E-15 YS 2.0 kg/M 2 Ref. 3, Table E-15 thin 7.78 x 106 S Ref. 3, Table E-15 (90 days)tf 1.73 x 10s Ref. 3, Table E-15 (2 days)H 8 g/m 3 Ref. 3 9-8 VER 29 VEGP ODCM 9.5 GRASS-GOAT-MILK PATHWAY FACTOR For radionuclides other than tritium in the grass-goat-milk pathway, Rapj in (m 2.mrem/y) per ([tCi/s) is calculated as follows (Reference 1, Section 5.3.1.3): Fff(1-f~fj)-' Ra=pi K, + r F .F,,, (DFLL. i + (Pf + (97)where: K 1 = the units conversion factor: 106 pCi/pCi.r = the fraction of deposited activity retained on the edible parts of vegetation (dimensionless). The value used for r is 1.0 for radioiodines and 0.2 for particulates, from (Reference 3, Table E-1).= the radioactive decay constant for radionuclide i, in s-1.Values of Xi used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.the rate constant for removal of activity on leaf and plant surfaces by weathering, in s-1, from Table 9-3.QF = the goat's consumption rate of feed, in kg/d, from Table 9-3.Uap = the consumption rate of goat milk by a receptor in age group a, in L/y, from Table 9-5.Fmi = the stable element transfer coefficient applicable to radionuclide i, for goat's milk, in d/L, from Table 9-6.(DFL)aij = the ingestion dose factor for receptor age group a, radionuclide i, and organ j, in mrem/pCi, from Table 9-11 through Table 9-14.fp = the fraction of the year that the goat is on pasture (dimensionless), from Table 9-3.f, = the fraction of the goat's feed that is pasture grass while the goat is on pasture (dimensionless), from Table 9-3.Yp = the areal density (agricultural productivity) of growing pasture feed grass, in kg/m , from Table 9-3.9-9 VER 29 VEGP ODCM Ys = the areal density (agricultural productivity) of growing stored feed, in kg/M 2 , from Table 9-3.thm = the transport time from harvest of stored feed to its consumption by the goat, in s, from Table 9-3.tf = the transport time from consumption of feed by the goat, to consumption of milk by the receptor, in s, from Table 9-3.For tritium in the grass-goat-milk pathway, Raipj in (mrem/y) per (AjCi/m 3) is calculated as follows (Reference 1, Section 5.3.1.5), based on the concentration in air rather than deposition onto the ground: Ra,pj = K.
- K 3 .Q, .'U .Fm, .(DFL),j .0. 75. (05) (9.8)where: K 3 = the units conversion factor: 10 3 g/kg.H = the absolute humidity of atmospheric air, in g/m 3 , from Table 9-3.0.75 = the fraction of the mass of total vegetation that is water (dimensionless).
0.5 = the ratio of the specific activity of tritium in vegetation water to that in atmospheric water (dimensionless). and other parameters are as defined above.9-10 VER 29 VEGP ODCM Table 9-3.Miscellaneous Parameters for the Grass-Goat-Milk Pathway The following parameter values are for use in calculating Raipj for the grass-goat-milk pathway only. The terms themselves are defined in section 9-5.Parameter Value Reference 5.73 x 107 s-I Ref. 1, page 33 (14-day half-life) QF 6 kg/d Ref. 3, Table E-3 fp 1.0 Ref. 1, page 33 fs 1.0 Ref. 1, page 33 Yp 0.7 kg/M 2 Ref. 3, Table E-15 Ys 2.0 kg/M 2 Ref. 3, Table E-15 thin 7.78 x 106 S Ref. 3, Table E-15 (90 days)tf 1.73 x 10 5 s Ref. 3, Table E-15 (2 days)H 8 g/m 3 Ref. 3 9-11 VER 29 VEGP ODCM 9.6 GRASS-COW-MEAT PATHWAY FACTOR For radionuclides other than tritium in the grass-cow-meat pathway, Raipj in (m 2-mrem/y) per (.Ci/s) is calculated as follows (Reference 1, Section 5.3.1.4): RaTV, r .FK 1.QL -,f,)*Uap
- 1 je- + (9.9)+ L11r: where: K 1 = the units conversion factor: 106 pCi/pCi.r = the fraction of deposited activity retained on the edible parts of vegetation (dimensionless).
The value used for r is 1.0 for radioiodines and 0.2 for particulates, from (Reference 3, Table E-1).i= the radioactive decay constant for radionuclide i, in s-1.Values of ki used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.x= the rate constant for removal of activity on leaf and plant surfaces by weathering, in s-1, from Table 9-4.QF = the cow's consumption rate of feed, in kg/d, from Table 9-4.Uap " the consumption rate of meat by a receptor in age group a, in kg/y, from Table 9-5.F,= the stable element transfer coefficient applicable to radionuclide i, for meat, in d/kg, from Table 9-6.(DFL)aij = the ingestion dose factor for receptor age group a, radionuclide i, and organ j, in mrem/pCi, from Table 9-11 through Table 9-14.fp = the fraction of the year that the cow is on pasture (dimensionless), from Table 9-4.fs = the fraction of the cow's feed that is pasture grass while the cow is on pasture (dimensionless), from Table 9-4.9-12 VER 29 VEGP ODCM Yp = the areal density (agricultural productivity) of growing pasture feed grass, in kg/mr, from Table 9-4.Ys = the areal density (agricultural productivity) of growing stored feed, in kg/M 2 , from Table 9-4.thrn = the transport time from harvest of stored feed to its consumption by the cow, in s, from Table 9-4.tf = the transport time from consumption of feed by the cow, to consumption of meat by the receptor, in s, from Table 9-4.For tritium in the grass-cow-meat pathway, Raapj in (mrem/y) per (lLCi/m 3) is calculated as follows (Reference 1, Section 5.3.1.4), based on the concentration in air rather than deposition onto the ground: Ra,j =K, .K 3 "QF U,,p .Ff .(DFL), (0.75.( 59.10)where: K 3 = the units conversion factor: 103 g/kg.H = the absolute humidity of atmospheric air, in g/m 3 , from Table 9-4.0.75 = the fraction of the mass of total vegetation that is water (dimensionless). 0.5 = the ratio of the specific activity of tritium in vegetation water to that in atmospheric water (dimensionless). and other parameters are as defined above.9-13 VER 29 VEGP ODCM Table 9-4.Miscellaneous Parameters for the Grass-Cow-Meat Pathway The following parameter values are for use in calculating Rapj for the grass-cow-meat pathway only. The terms themselves are defined in section 9-6.Parameter Value Reference xw 5.73 x 10-7 s-1 Ref. 1, page 33 (14-day half-life) QF 50 kg/d Ref. 3, Table E-3 fp 1.0 Ref. 1, page 33 f. 1.0 Ref. 1, page 33 Yp 0.7 kg/M 2 Ref. 3, Table E-15 YS 2.0 kg/M 2 Ref. 3, Table E-15 thin 7.78 x 106 s Ref. 3, Table E-15 (90 days)tf 1.73 x10 6 s Ref. 3, Table E-15 (20 days)H 8 g/m 3 Ref. 3 9-14 VER 29 VEGP ODCM Table 9-5. Individual Usage Factors Receptor Age Group Usage Factor Infant Child Teenager Adult Milk Consumption Rate, Uap 330 330 400 310 (L/y)Meat Consumption Rate, Uap 0 41 65 110 (kg/y)Fresh Leafy Garden Vegetation 0 26 42 64 Consumption Rate, UaL (kg/y)Stored Garden Vegetation 0 520 630 520 Consumption Rate, Uas (kg/y)Breathing Rate, (BR), 1400 3700 8000 8000 (m 3/y) I I All values are from Reference 3, Table E-5.9-15 VER 29 VEGP ODCM Table 9-6.Stable Element Transfer Data Cow Milk Goat Milk Meat Element Fm (d/L)" Fm (d/L)÷ Ff (d/kg)*H 1.0 E-02 1.7 E-01 1.2 E-02 C 1.2 E-02 1.0 E-01 3.1 E-02 Na 4.0 E-02 4.0 E-02 3.0 E-02 P 2.5 E-02 2.5 E-01 4.6 E-02 Cr 2.2 E-03 2.2 E-03 2.4 E-03 Mn 2.5 E-04 2.5 E-04 8.0 E-04 Fe 1.2 E-03 1.3 E-04 4.0 E-02 Co 1.0 E-03 1.0 E-03 1.3 E-02 Ni 6.7 E-03 6.7 E-03 5.3 E-02 Cu 1.4 E-02 1.3 E-02 8.0 E-03 Zn 3.9 E-02 3.9 E-02 3.0 E-02 Br 5.0 E-02 5.0 E-02 2.6 E-02 Rb 3.0 E-02 3.0 E-02 3.1 E-02 Sr 8.0 E-04 1.4 E-02 6.0 E-04 Y 1.0 E-05 1.0 E-05 4.6 E-03 Zr 5.0 E-06 5.0 E-06 3.4 E-02 Nb 2.5 E-03 2.5 E-03 2.8 E-01 Mo 7.5 E-03 7.5 E-03 8.0 E-03 Tc 2.5 E-02 2.5 E-02 4.0 E-01 Ru 1.0 E-06 1.0 E-06 4.0 E-01 Rh 1.0 E-02 1.0 E-02 1.5 E-03 Ag 5.0 E-02 5.0 E-02 1.7 E-02 Sb 1.5 E-03 1.5 E-03 4.0 E-03 Te 1.0 E-03 1.0 E-03 7.7 E-02 1 6.0 E-03 6.0 E-02 2.9 E-03 Cs 1.2 E-02 3.0 E-01 4.0 E-03 Ba 4.0 E-04 4.0 E-04 3.2 E-03 La 5.0 E-06 5.0 E-06 2.0 E-04 Ce 1.0 E-04 1.0 E-04 1.2 E-03 Pr 5.0 E-06 5.0 E-06 4.7 E-03 Nd 5.0 E-06 5.0 E-06 3.3 E-03 W 5.0 E-04 5.0 E-04 1.3 E-03 Np 5.0 E-06 5.0 E-06 2.0 E-04* -Values from Reference 3 for Br and Sb.(Table E-1) except as follows: Reference 2 (Table C-5)+ -Values from Reference 3, Table E-2 for H, C, P, Fe, Cu, Sr, I, and Cs in goat milk, and Table E-1 for all other elements in cow milk, except as follows: Reference 2 (Table C-5) for Br and Sb in cow milk.9-16 VER 29 VEGP ODCM Table 9-7. Inhalation Dose Factors for the Infant Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI H-3 No Data 4.62E-07 4.62E-07 4.62E-07 4.62E-07 4.62E-07 4.62E-07 C-14 1.89E-05 3.79E-06 3.79E-06 3.79E-06 3.79E-06 3.79E-06 3.79E-06 Na-24 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 P-32 1.45E-03 8.03E-05 5.53E-05 No Data No Data No Data 1.15E-05 Cr-51 No Data No Data 6.39E-08 4.11E-08 9.45E-09 9.17E-06 2.55E-07 Mn-54 No Data 1.81E-05 3.56E-06 No Data 3.56E-06 7.14E-04 5.04E-06 Mn-56 No Data 1.1OE-09 1.58E-10 No Data 7.86E-10 8.95E-06 5.12E-05 Fe-55 1.41 E-05 8.39E-06 2.38E-06 No Data No Data 6.21 E-05 7.82E-07 Fe-59 9.69E-06 1.68E-05 6.77E-06 No Data No Data 7.25E-04 1.77E-05 Co-58 No Data 8.71 E-07 1.30E-06 No Data No Data 5.55E-04 7.95E-06 Co-60 No Data 5.73E-06 8.41E-06 No Data No Data 3.22E-03 2.28E-05 Ni-63 2.42E-04 1.46E-05 8.29E-06 No Data No Data 1.49E-04 1.73E-06 Ni-65 1.71E-09 2.03E-10 8.79E-11 No Data No Data 5.80E-06 3.58E-05 Cu-64 No Data 1.34E-09 5.53E-10 No Data 2.84E-09 6.64E-06 1.07E-05 Zn-65 1.38E-05 4.47E-05 2.22E-05 No Data 2.32E-05 4.62E-04 3.67E-05 Zn-69 3.85E-11 6.91E-11 5.13E-12 No Data 2.87E-11 1.05E-06 9.44E-06 Br-83 No Data No Data 2.72E-07 No Data No Data No Data No Data Br-84 No Data No Data 2.86E-07 No Data No Data No Data No Data Br-85 No Data No Data 1.46E-08 No Data No Data No Data No Data Rb-86 No Data 1.36E-04 6.30E-05 No Data No Data No Data 2.17E-06 Rb-88 No Data 3.98E-07 2.05E-07 No Data No Data No Data 2.42E-07 Rb-89 No Data 2.29E-07 1.47E-07 No Data No Data No Data 4.87E-08 Sr-89 2.84E-04 No Data 8.15E-06 No Data No Data 1.45E-03 4.57E-05 Sr-90 2.92E-02 No Data 1.85E-03 No Data No Data 8.03E-03 9.36E-05 Sr-91 6.83E-08 No Data 2.47E-09 No Data No Data 3.76E-05 5.24E-05 All values are in (mrem/pCi inhaled). They are obtained from Reference 3 (Table E-10). Neither Reference 2 nor Reference 3 contains data for Rh-105, Sb-124, or Sb-125.9-17 VER 29 VEGP ODCM 9-18 VER 29 VEGP ODCM Table 9-7 (contd). Inhalation Dose Factors for the Infant Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 7.50E-09 No Data 2.79E-10 No Data No Data 1.70E-05 1.OOE-04 Y-90 2.35E-06 No Data 6.30E-08 No Data No Data 1.92E-04 7.43E-05 Y-91m 2.91E-10 No Data 9.90E-12 No Data No Data 1.99E-06 1.68E-06 Y-91 Y-92 Y-93 4.20E-04 1.17E-08 1.07E-07 No Data No Data No Data 1.12E-05 3.29E-10 2.91 E-09 No Data No Data No Data No Data No Data No Data 1.75E-03 1.75E-05 5.46E-05 5.02E-05 9.04E-05 1.19E-04 Zr-95 8.24E-05 1.99E-05 1.45E-05 No Data 2.22E-05 1.25E-03 1.55E-05 Zr-97 1.07E-07 1.83E-08 8.36E-09 No Data 1.85E-08 7.88E-05 1.OOE-04 Nb-95 1.12E-05 4.59E-06 2.70E-06 No Data 3.37E-06 3.42E-04 9.05E-06 Mo-99 No Data 1.18E-07 2.31E-08 No Data 1.89E-07 9.63E-05 3.48E-05 Tc-99m 9.98E-13 2.06E-12 2.66E-11 No Data 2.22E-11 5.79E-07 1.45E-06 Tc-101 4.65E-14 5.88E-14 5.80E-13 No Data 6.99E-13 4.17E-07 6.03E-07 Ru-103 1.44E-06 No Data 4.85E-07 No Data 3.03E-06 3.94E-04 1.15E-05 Ru-105 8.74E-10 No Data 2.93E-10 No Data 6.42E-10 1.12E-05 3.46E-05 Ru-106 6.20E-05 No Data 7.77E-06 No Data 7.61E-05 8.26E-03 1.17E-04 Rh-105 No Data No Data No Data No Data No Data No Data No Data Ag-110m 7.13E-06 5.16E-06 3.57E-06 No Data 7.80E-06 2.62E-03 2.36E-05 Sb-124 No Data No Data No Data No Data No Data No Data No Data Sb-125 No Data No Data No Data No Data No Data No Data No Data Te-125m 3.40E-06 1.42E-06 4.70E-07 1.16E-06 No Data 3.19E-04 9.22E-06 Te-127m 1.19E-05 4.93E-06 1.48E-06 3.48E-06 2.68E-05 9.37E-04 1.95E-05 Te-127 1.59E-09 6.81E-10 3.49E-10 1.32E-09 3.47E-09 7.39E-06 1.74E-05 Te-129m 1.01E-05 4.35E-06 1.59E-06 3.91E-06 2.27E-05 1.20E-03 4.93E-05 Te-129 5.63E-11 2.48E-11 1.34E-11 4.82E-11 1.25E-10 2.14E-06 1.88E-05 Te-131rm 7.62E-08 3.93E-08 2.59E-08 6.38E-08 1.89E-07 1.42E-04 8.51E-05 Te-131 1.24E-11 5.87E-12 3.57E-12 1.13E-11 2.85E-11 1.47E-06 5.87E-06 9-19 VER 29 VEGP ODCM Table 9-7 (contd). Inhalation Dose Factors for the Infant Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 2.66E-07 1.69E-07 1.26E-07 1.99E-07 7.39E-07 2.43E-04 3.15E-05 1-130 4.54E-06 9.91E-06 3.98E-06 1.14E-03 1.09E-05 No Data 1.42E-06 1-131 2.71E-05 3.17E-05 1.40E-05 1.06E-02 3.70E-05 No Data 7.56E-07 1-132 1.21E-06 2.53E-06 8.99E-07 1.21E-04 2.82E-06 No Data 1.36E-06 1-133 9.46E-06 1.37E-05 4.OOE-06 2.54E-03 1.60E-05 No Data 1.54E-06 1-134 6.58E-07 1.34E-06 4.75E-07 3.18E-05 1.49E-06 No Data 9.21E-07 1-135 2.76E-06 5.43E-06 1.98E-06 4.97E-04 6.05E-06 No Data 1.31E-06 Cs-134 2.83E-04 5.02E-04 5.32E-05 No Data 1.36E-04 5.69E-05 9.53E-07 Cs-136 3.45E-05 9.61E-05 3.78E-05 No Data 4.03E-05 8.40E-06 1.02E-06 Cs-137 3.92E-04 4.37E-04 3.25E-05 No Data 1.23E-04 5.09E-05 9.53E-07 Cs-138 3.61E-07 5.58E-07 2.84E-07 No Data 2.93E-07 4.67E-08 6.26E-07 Ba-139 1.06E-09 7.03E-13 3.07E-11 No Data 4.23E-13 4.25E-06 3.64E-05 Ba-140 4.OOE-05 4.OOE-08 2.07E-06 No Data 9.59E-09 1.14E-03 2.74E-05 Ba-141 1.12E-10 7.70E-14 3.55E-12 No Data 4.64E-14 2.12E-06 3.39E-06 Ba-142 2.84E-11 2.36E-14 1.40E-12 No Data 1.36E-14 1.11E-06 4.95E-07 La-140 3.61E-07 1.43E-07 3.68E-08 No Data No Data 1.20E-04 6.06E-05 La-142 7.36E-10 2.69E-10 6.46E-11 No Data No Data 5.87E-06 4.25E-05 Ce-141 1.98E-05 1.19E-05 1.42E-06 No Data 3.75E-06 3.69E-04 1.54E-05 Ce-143 2.09E-07 1.38E-07 1.58E-08 No Data 4.03E-08 8.30E-05 3.55E-05 Ce-144 2.28E-03 8.65E-04 1.26E-04 No Data 3.84E-04 7.03E-03 1.06E-04 Pr-143 1.OOE-05 3.74E-06 4.99E-07 No Data 1.41E-06 3.09E-04 2.66E-05 Pr-144 3.42E-11 1.32E-11 1.72E-12 No Data 4.80E-12 1.15E-06 3.06E-06 Nd-147 5.67E-06 5.81E-06 3.57E-07 No Data 2.25E-06 2.30E-04 2.23E-05 W-187 9.26E-09 6.44E-09 2.23E-09 No Data No Data 2.83E-05 2.54E-05 Np-239 2.65E-07 2.37E-08 1.34E-08 No Data 4.73E-08 4.25E-05 1.78E-05 9-20 VER 29 VEGP ODCM Table 9-8.Inhalation Dose Factors for the Child Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 No Data 3.04E-07 3.04E-07 3.04E-07 3.04E-07 3.04E-07 3.04E-07 C-14 9.70E-06 1.82E-06 1.82E-06 1.82E-06 1.82E-06 1.82E-06 1.82E-06 Na-24 4.35E-06 4.35E-06 4.35E-06 4.35E-06 4.35E-06 4.35E-06 4.35E-06 P-32 7.04E-04 3.09E-05 2.67E-05 No Data No Data No Data 1.14E-05 Cr-51 No Data No Data 4.17E-08 2.31E-08 6.57E-09 4.59E-06 2.93E-07 Mn-54 No Data 1.16E-05 2.57E-06 No Data 2.71E-06 4.26E-04 6.19E-06 Mn-56 No Data 4.48E-10 8.43E-11 No Data 4.52E-10 3.55E-06 3.33E-05 Fe-55 1.28E-05 6.80E-06 2.1OE-06 No Data No Data 3.OOE-05 7.75E-07 Fe-59 5.59E-06 9.04E-06 4.51 E-06 No Data No Data 3.43E-04 1.91 E-05 Co-58 No Data 4.79E-07 8.55E-07 No Data No Data 2.99E-04 9.29E-06 Co-60 No Data 3.55E-06 6.12E-06 No Data No Data 1.91E-03 2.60E-05 Ni-63 2.22E-04 1.25E-05 7.56E-06 No Data No Data 7.43E-05 1.71E-06 Ni-65 8.08E-10 7.99E-11 4.44E-11 No Data No Data 2.21 E-06 2.27E-05 Cu-64 No Data 5.39E-10 2.90E-10 No Data 1.63E-09 2.59E-06 9.92E-06 Zn-65 1.15E-05 3.06E-05 1.90E-05 No Data 1.93E-05 2.69E-04 4.41 E-06 Zn-69 1.81E-11 2.61E-11 2.41E-12 No Data 1.58E-11 3.84E-07 2.75E-06 Br-83 No Data No Data 1.28E-07 No Data No Data No Data No Data Br-84 No Data No Data 1.48E-07 No Data No Data No Data No Data Br-85 No Data No Data 6.84E-09 No Data No Data No Data No Data Rb-86 No Data 5.36E-05 3.09E-05 No Data No Data No Data 2.16E-06 Rb-88 No Data 1.52E-07 9.90E-08 No Data No Data No Data 4.66E-09 Rb-89 No Data 9.33E-08 7.83E-08 No Data No Data No Data 5.11 E-1 0 Sr-89 1.62E-04 No Data 4.66E-06 No Data No Data 5.83E-04 4.52E-05 Sr-90 2.73E-02 No Data 1.74E-03 No Data No Data 3.99E-03 9.28E-05 Sr-91 3.28E-08 No Data 1.24E-09 No Data No Data 1.44E-05 4.70E-05 All values are in (mrem/pCi inhaled). They are obtained from Reference 3 (Table E-9). Neither Reference 2 nor Reference 3 contains data for Rh-105, Sb-1 24, or Sb-1 25.9-21 VER 29 VEGP ODCM 9-22 VER 29 VEGP ODCM Table 9-8 (contd).Inhalation Dose Factors for the Child Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 3.54E-09 No Data 1.42E-10 No Data No Data 6.49E-06 6.55E-05 Y-90 1.11E-06 No Data 2.99E-08 No Data No Data 7.07E-05 7.24E-05 Y-91m 1.37E-10 No Data 4.98E-12 No Data No Data 7.60E-07 4.64E-07 Y-91 2.47E-04 No Data 6.59E-06 No Data No Data 7.1OE-04 4.97E-05 Y-92 5.50E-09 No Data 1.57E-10 No Data No Data 6.46E-06 6.46E-05 Y-93 5.04E-08 No Data 1.38E-09 No Data No Data 2.01 E-05 1.05E-04 Zr-95 5.13E-05 1.13E-05 1.OOE-05 No Data 1.61E-05 6.03E-04 1.65E-05 Zr-97 5.07E-08 7.34E-09 4.32E-09 No Data 1.05E-08 3.06E-05 9.49E-05 Nb-95 6.35E-06 2.48E-06 1.77E-06 No Data 2.33E-06 1.66E-04 11.00E-05 Mo-99 No Data 4.66E-08 1.15E-08 No Data 1.06E-07 3.66E-05 3.42E-05 Tc-99m 4.81E-13 9.41E-13 1.56E-11 No Data 1.37E-11 2.57E-07 1.30E-06 Tc-101 2.19E-14 2.30E-14 2.91E-13 No Data 3.92E-13 1.58E-07 4.41E-09 Ru-103 7.55E-07 No Data 2.90E-07 No Data 1.90E-06 1.79E-04 1.21E-05 Ru-105 4.13E-10 No Data 1.50E-10 No Data 3.63E-10 4.30E-06 2.69E-05 Ru-106 3.68E-05 No Data 4.57E-06 No Data 4.97E-05 3.87E-03 1.16E-04 Rh-105 No Data No Data No Data No Data No Data No Data No Data Ag-1 10m 4.56E-06 3.08E-06 2.47E-06 No Data 5.74E-06 1.48E-03 2.71 E-05 Sb-124 No Data No Data No Data No Data No Data No Data No Data Sb-125 No Data No Data No Data No Data No Data No Data No Data Te-125m 1.82E-06 6.29E-07 2.47E-07 5.20E-07 No Data 1.29E-04 9.13E-06 Te-127m 6.72E-06 2.31E-06 8.16E-07 1.64E-06 1.72E-05 4.OOE-04 1.93E-05 Te-127 7.49E-10 2.57E-10 1.65E-10 5.30E-10 1.91E-09 2.71E-06 1.52E-05 Te-129m 5.19E-06 1.85E-06 8.22E-07 1.71E-06 1.36E-05 4.76E-04 4.91E-05 Te-129 2.64E-11 9.45E-12 6.44E-12 1.93E-11 6.94E-11 7.93E-07 6.89E-06 Te-131m 3.63E-08 1.60E-08 1.37E-08 2.64E-08 1.08E-07 5.56E-05 8.32E-05 Te-131 5.87E-12 2.28E-12 1.78E-12 4.59E-12 1.59E-11 5.55E-07 3.60E-07 9-23 VER 29 VEGP ODCM Table 9-8 (contd). Inhalation Dose Factors for the Child Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 1.30E-07 7.36E-08 7.12E-08 8.58E-08 4.79E-07 1.02E-04 3.72E-05 1-130 2.21E-06 4.43E-06 2.28E-06 4.99E-04 6.61E-06 No Data 1.38E-06 1-131 1.30E-05 1.30E-05 7.37E-06 4.39E-03 2.13E-05 No Data 7.68E-07 1-132 5.72E-07 1.1OE-06 5.07E-07 5.23E-05 1.69E-06 No Data 8.65E-07 1-133 4.48E-06 5.49E-06 2.08E-06 1.04E-03 9.13E-06 No Data 1.48E-06 1-134 3.17E-07 5.84E-07 2.69E-07 1.37E-05 8.92E-07 No Data 2.58E-07 1-135 1.33E-06 2.36E-06 1.12E-06 2.14E-04 3.62E-06 No Data 1.20E-06 Cs-134 1.76E-04 2.74E-04 6.07E-05 No Data 8.93E-05 3.27E-05 1.04E-06 Cs-136 1.76E-05 4.62E-05 3.14E-05 No Data 2.58E-05 3.93E-06 1.13E-06 Cs-137 2.45E-04 2.23E-04 3.47E-05 No Data 7.63E-05 2.81E-05 9.78E-07 Cs-138 1.71E-07 2.27E-07 1.50E-07 No Data 1.68E-07 1.84E-08 7.29E-08 Ba-139 4.98E-10 2.66E-13 1.45E-11 No Data 2.33E-13 1.56E-06 1.56E-05 Ba-140 2.OOE-05 1.75E-08 1.17E-06 No Data 5.71E-09 4.71E-04 2.75E-05 Ba-141 5.29E-11 2.95E-14 1.72E-12 No Data 2.56E-14 7.89E-07 7.44E-08 Ba-142 1.35E-11 9.73E-15 7.54E-13 No Data 7.87E-15 4.44E-07 7.41 E-10 La-140 1.74E-07 6.08E-08 2.04E-08 No Data No Data 4.94E-05 6.1OE-05 La-142 3.50E-10 1.11E-10 3.49E-11 No Data No Data 2.35E-06 2.05E-05 Ce-141 1.06E-05 5.28E-06 7.83E-07 No Data 2.31E-06 1.47E-04 1.53E-05 Ce-143 9.89E-08 5.37E-08 7.77E-09 No Data 2.26E-08 3.12E-05 3.44E-05 Ce-144 1.83E-03 5.72E-04 9.77E-05 No Data 3.17E-04 3.23E-03 1.05E-04 Pr-143 4.99E-06 1.50E-06 2.47E-07 No Data 8.11E-07 1.17E-04 2.63E-05 Pr-144 1.61E-11 4.99E-12 8.10E-13 No Data 2.64E-12 4.23E-07 5.32E-08 Nd-147 2.92E-06 2.36E-06 1.84E-07 No Data 1.30E-06 8.87E-05 2.22E-05 W-187 4.41E-09 2.61E-09 1.17E-09 No Data No Data 1.11E-05 2.46E-05 Np-239 1.26E-07 9.04E-09 6.35E-09 No Data 2.63E-08 1.57E-05 1.73E-05 9-24 VER 29 VEGP ODCM Table 9-9. Inhalation Dose Factors for the Teenager Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI H-3 No Data 1.59E-07 1.59E-07 1.59E-07 1.59E-07 1.59E-07 1.59E-07 C-14 3.25E-06 6.09E-07 6.09E-07 6.09E-07 6.09E-07 6.09E-07 6.09E-07 Na-24 1.72E-06 1.72E-06 1.72E-06 1.72E-06 1.72E-06 1.72E-06 1.72E-06 P-32 2.36E-04 1.37E-08 8.95E-06 No Data No Data No Data 1.16E-05 Cr-51 No Data No Data 1.69E-08 9.37E-09 3.84E-09 2.62E-06 3.75E-07 Mn-54 No Data 6.39E-06 1.05E-06 No Data 1.59E-06 2.48E-04 8.35E-06 Mn-56 No Data 2.12E-10 3.15E-11 No Data 2.24E-10 1.90E-06 7.18E-06 Fe-55 4.18E-06 2.98E-06 6.93E-07 No Data No Data 1.55E-05 7.99E-07 Fe-59 1.99E-06 4.62E-06 1.79E-06 No Data No Data 1.91 E-04 2.23E-05 Co-58 No Data 2.59E-07 3.47E-07 No Data No Data 1.68E-04 1.1 9E-05 Co-60 No Data 1.89E-06 2.48E-06 No Data No Data 1.09E-03 3.24E-05 Ni-63 7.25E-05 5.43E-06 2.47E-06 No Data No Data 3.84E-05 1.77E-06 Ni-65 2.73E-10 3.66E-11 1.59E-11 No Data No Data 1.17E-06 4.59E-06 Cu-64 No Data 2.54E-10 1.06E-10 No Data 8.01E-10 1.39E-06 7.68E-06 Zn-65 4.82E-06 1.67E-05 7.80E-06 No Data 1.08E-05 1.55E-04 5.83E-06 Zn-69 6.04E-12 1.15E-11 8.07E-13 No Data 7.53E-12 1.98E-07 3.56E-08 Br-83 No Data No Data 4.30E-08 No Data No Data No Data No Data Br-84 No Data No Data 5.41 E-08 No Data No Data No Data No Data Br-85 No Data No Data 2.29E-09 No Data No Data No Data No Data Rb-86 No Data 2.38E-05 1.05E-05 No Data No Data No Data 2.21 E-06 Rb-88 No Data 6.82E-08 3.40E-08 No Data No Data No Data 3.65E-15 Rb-89 No Data 4.40E-08 2.91E-08 No Data No Data No Data 4.22E-17 Sr-89 5.43E-05 No Data 1.56E-06 No Data No Data 3.02E-04 4.64E-05 Sr-90 1.35E-02 No Data 8.35E-04 No Data No Data 2.06E-03 9.56E-05 Sr-91 1.1OE-08 No Data 4.39E-10 No Data No Data 7.59E-06 3.24E-05 All values are in (mrem/pCi inhaled). They are obtained from Reference 3 (Table E-8). Neither Reference 2 nor Reference 3 contains data for Rh-1 05, Sb-124, or Sb-125.9-25 VER 29 VEGP ODCM Table 9-9 (contd). Inhalation Dose Factors for the Teenager Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 1.19E-09 No Data 5.08E- 11 No Data No Data 3.43E-06 1.49E-05 Y-90 3.73E-07 No Data 1.OOE-08 No Data No Data 3.66E-05 6.99E-05 Y-91m 4.63E-11 No Data 1.77E-12 No Data No Data 4.OOE-07 3.77E-09 Y-91 8.26E-05 No Data 2.21E-06 No Data No Data 3.67E-04 5.11E-05 Y-92 1.84E-09 No Data 5.36E-1 1 No Data No Data 3.35E-06 2.06E-05 Y-93 1.69E-08 No Data 4.65E-10 No Data No Data 1.04E-05 7.24E-05 Zr-95 1.82E-05 5.73E-06 3.94E-06 No Data 8.42E-06 3.36E-04 1.86E-05 Zr-97 1.72E-08 3.40E-09 1.57E-09 No Data 5.15E-09 1.62E-05 7.88E-05 Nb-95 2.32E-06 1.29E-06 7.08E-07 No Data 1.25E-06 9.39E-05 1.21E-05 Mo-99 No Data 2.11E-08 4.03E-09 No Data 5.14E-08 1.92E-05 3.36E-05 Tc-99m 1.73E-13 4.83E-13 6.24E-12 No Data 7.20E-12 1.44E-07 7.66E-07 Tc-101 7.40E-15 1.05E-14 1.03E-13 No Data 1.90E-13 8.34E-08 1.09E-16 Ru-103 2.63E-07 No Data 1.12E-07 No Data 9.29E-07 9.79E-05 1.36E-05 Ru-105 1.40E-10 No Data 5.42E-11 No Data 1.76E-10 2.27E-06 1.13E-05 Ru-106 1.23E-05 No Data 1.55E-06 No Data 2.38E-05 2.01E-03 1.20E-04 Rh-105 No Data No Data No Data No Data No Data No Data No Data Ag-110m 1.73E-06 1.64E-06 9.99E-07 No Data 3.13E-06 8.44E-04 3.41E-05 Sb-124 No Data No Data No Data No Data No Data No Data No Data Sb-125 No Data No Data No Data No Data No Data No Data No Data Te-125m 6.1OE-07 2.80E-07 8.34E-08 1.75E-07 No Data 6.70E-05 9.38E-06 Te-127m 2.25E-06 1.02E-06 2.73E-07 5.48E-07 8.17E-06 2.07E-04 1.99E-05 Te-127 2.51E-10 1.14E-10 5.52E-11 1.77E-10 9.10E-10 1.40E-06 1.01E-05 Te-129m 1.74E-06 8.23E-07 2.81E-07 5.72E-07 6.49E-06 2.47E-04 5.06E-05 Te-129 8.87E-12 4.22E-12 2.20E-12 6.48E-12 3.32E-11 4.12E-07 2.02E-07 Te-131m 1.23E-08 7.51E-09 5.03E-09 9.06E-09 5.49E-08 2.97E-05 7.76E-05 Te-131 1.97E-12 1.04E-12 6.30E-13 1.55E-12 7.72E-12 2.92E-07 1.89E-09 9-26 VER 29 VEGP ODCM Table 9-9 (contd). Inhalation Dose Factors for the Teenager Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 4.50E-08 3.63E-08 2.74E-08 3.07E-08 2.44E-07 5.61E-05 5.79E-05 1-130 7.80E-07 2.24E-06 8.96E-07 1.86E-04 3.44E-06 No Data 1.14E-06 1-131 4.43E-06 6.14E-06 3.30E-06 1.83E-03 1.05E-05 No Data 8.11E-07 1-132 1.99E-07 5.47E-07 1.97E-07 1.89E-05 8.65E-07 No Data 1.59E-07 1-133 1.52E-06 2.56E-06 7.78E-07 3.65E-04 4.49E-06 No Data 1.29E-06 1-134 1.11E-07 2.90E-07 1.05E-07 4.94E-06 4.58E-07 No Data 2.55E-09 1-135 4.62E-07 1.18E-06 4.36E-07 7.76E-05 1.86E-06 No Data 8.69E-07 Cs-134 6.28E-05 1.41E-04 6.86E-05 No Data 4.69E-05 1.83E-05 1.22E-06 Cs-136 6.44E-06 2.42E-05 1.71E-05 No Data 1.38E-05 2.22E-06 1.36E-06 Cs-137 8.38E-05 1.06E-04 3.89E-05 No Data 3.80E-05 1.51E-05 1.06E-06 Cs-138 5.82E-08 1.07E-07 5.58E-08 No Data 8.28E-08 9.84E-09 3.38E-11 Ba-139 1.67E-10 1.18E-13 4.87E-12 No Data 1.11E-13 8.08E-07 8.06E-07 Ba-140 6.84E-06 8.38E-09 4.40E-07 No Data 2.85E-09 2.54E-04 2.86E-05 Ba-141 1.78E-11 1.32E-14 5.93E-13 No Data 1.23E-14 4.11E-07 9.33E-14 Ba-142 4.62E-12 4.63E-15 2.84E-13 No Data 3.92E-15 2.39E-07 5.99E-20 La-140 5.99E-08 2.95E-08 7.82E-09 No Data No Data 2.68E-05 6.09E-05 La-142 1.20E-10 5.31E-11 1.32E-11 No Data No Data 1.27E-06 1.50E-06 Ce-141 3.55E-06 2.37E-06 2.71E-07 No Data 1.11E-06 7.67E-05 1.58E-05 Ce-143 3.32E-08 2.42E-08 2.70E-09 No Data 1.08E-08 1.63E-05 3.19E-05 Ce-144 6.11E-04 2.53E-04 3.28E-05 No Data 1.51E-04 1.67E-03 1.08E-04 Pr-143 1.67E-06 6.64E-07 8.28E-08 No Data 3.86E-07 6.04E-05 2.67E-05 Pr-144 5.37E-12 2.20E-12 2.72E-13 No Data 1.26E-12 2.19E-07 2.94E-14 Nd-147 9.83E-07 1.07E-06 6.41E-08 No Data 6.28E-07 4.65E-05 2.28E-05 W-187 1.50E-09 1.22E-09 4.29E-10 No Data No Data 5.92E-06 2.21E-05 Np-239 4.23E-08 3.99E-09 2.21E-09 No Data 1.25E-08 8.11E-06 1.65E-05 9-27 VER 29 VEGP ODCM Table 9-10. Inhalation Dose Factors for the Adult Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 No Data 1.58E-07 1.58E-07 1.58E-07 1.58E-07 1.58E-07 1.58E-07 C-14 2.27E-06 4.26E-07 4.26E-07 4.26E-07 4.26E-07 4.26E-07 4.26E-07 Na-24 1.28E-06 1.28E-06 1.28E-06 1.28E-06 1.28E-06 1.28E-06 1.28E-06 P-32 1.65E-04 9.64E-06 6.26E-06 No Data No Data No Data 1.08E-05 Cr-51 No Data No Data 1.25E-08 7.44E-09 2.85E-09 1.80E-06 4.15E-07 Mn-54 No Data 4.95E-06 7.87E-07 No Data 1.23E-06 1.75E-04 9.67E-06 Mn-56 No Data 1.55E-10 2.29E-11 No Data 1.63E-10 1.18E-06 2.53E-06 Fe-55 3.07E-06 2.12E-06 4.93E-07 No Data No Data 9.01E-06 7.54E-07 Fe-59 1.47E-06 3.47E-06 1.32E-06 No Data No Data 1.27E-04 2.35E-05 Co-58 No Data 1.98E-07 2.59E-07 No Data No Data 1.16E-04 1.33E-05 Co-60 No Data 1.44E-06 1.85E-06 No Data No Data 7.46E-04 3.56E-05 Ni-63 5.40E-05 3.93E-06 1.81E-06 No Data No Data 2.23E-05 1.67E-06 Ni-65 1.92E-10 2.62E-11 1.14E-11 No Data No Data 7.OOE-07 1.54E-06 Cu-64 No Data 1.83E-10 7.69E-11 No Data 5.78E-10 8.48E-07 6.12E-06 Zn-65 4.05E-06 1.29E-05 5.82E-06 No Data 8.62E-06 1.08E-04 6.68E-06 Zn-69 4.23E-12 8.14E-12 5.65E-13 No Data 5.27E-12 1.15E-07 2.04E-09 Br-83 No Data No Data 3.01E-08 No Data No Data No Data 2.90E-08 Br-84 No Data No Data 3.91 E-08 No Data No Data No Data 2.05E-13 Br-85 No Data No Data 1.60E-09 No Data No Data No Data No Data Rb-86 No Data 1.69E-05 7.37E-06 No Data No Data No Data 2.08E-06 Rb-88 No Data 4.84E-08 2.41E-08 No Data No Data No Data 4.18E-19 Rb-89 No Data 3.20E-08 2.12E-08 No Data No Data No Data 1.16E-21 Sr-89 3.80E-05 No Data 1.09E-06 No Data No Data 1.75E-04 4.37E-05 Sr-90 1.24E-02 No Data 7.62E-04 No Data No Data 1.20E-03 9.02E-05 Sr-91 7.74E-09 No Data 3.13E-10 No Data No Data 4.56E-06 2.39E-05 All values are in (mrem/pCi inhaled). They are obtained from Reference 3 (Table E-7), except as follows: Reference 2 (Table C-1) for Rh-105, Sb-124, and Sb-125.9-28 VER 29 VEGP ODCM Table 9-10 (contd). Inhalation Dose Factors for the Adult Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 8.43E-1 0 No Data 3.64E-1 1 No Data No Data 2.06E-06 5.38E-06 Y-90 2.61E-07 No Data 7.01 E-09 No Data No Data 2.12E-05 6.32E-05 Y-91m 3.26E-11 No Data 1.27E-12 No Data No Data 2.40E-07 1.66E-10 Y-91 5.78E-05 No Data 1.55E-06 No Data No Data 2.13E-04 4.81 E-05 Y-92 1.29E-09 No Data 3.77E-11 No Data No Data 1.96E-06 9.19E-06 Y-93 1.18E-08 No Data 3.26E-10 No Data No Data 6.06E-06 5.27E-05 Zr-95 1.34E-05 4.30E-06 2.91E-06 No Data 6.77E-06 2.21E-04 1.88E-05 Zr-97 1.21E-08 2.45E-09 1.13E-09 No Data 3.71E-09 9.84E-06 6.54E-05 Nb-95 1.76E-06 9.77E-07 5.26E-07 No Data 9.67E-07 6.31E-05 1.30E-05 Mo-99 No Data 1.51E-08 2.87E-09 No Data 3.64E-08 1.14E-05 3.1OE-05 Tc-99m 1.29E-13 3.64E-13 4.63E-12 No Data 5.52E-12 9.55E-08 5.20E-07 Tc-101 5.22E-15 7.52E-15 7.38E-14 No Data 1.35E-13 4.99E-08 1.36E-21 Ru-103 1.91 E-07 No Data 8.23E-08 No Data 7.29E-07 6.31E-05 1.38E-05 Ru-105 9.88E-11 No Data 3.89E-11 No Data 1.27E-10 1.37E-06 6.02E-06 Ru-106 8.64E-06 No Data 1.09E-06 No Data 1.67E-05 1.17E-03 1.14E-04 Rh-105 9.24E-10 6.73E-10 4.43E-10 No Data 2.86E-09 2.41E-06 1.09E-05 Ag-110m 1.35E-06 1.25E-06 7.43E-07 No Data 2.46E-06 5.79E-04 3.78E-05 Sb-124 3.90E-06 7.36E-08 1.55E-06 9.44E-09 No Data 3.1OE-04 5.08E-05 Sb-125 8.26E-06 8.91E-08 1.66E-06 7.34E-09 No Data 2.75E-04 1.26E-05 Te-125m 4.27E-07 1.98E-07 5.84E-08 1.31E-07 1.55E-06 3.92E-05 8.83E-06 Te-127m 1.58E-06 7.21E-07 1.96E-07 4.11E-07 5.72E-06 1.20E-04 1.87E-05 Te-127 1.75E-10 8.03E-11 3.87E-11 1.32E-10 6.37E-10 8.14E-07 7.17E-06 Te-129m 1.22E-06 5.84E-07 1.98E-07 4.30E-07 4.57E-06 1.45E-04 4.79E-05 Te-129 6.22E-12 2.99E-12 1.55E-12 4.87E-12 2.34E-11 2.42E-07 1.96E-08 Te-131rm 8.74E-09 5.45E-09 3.63E-09 6.88E-09 3.86E-08 1.82E-05 6.95E-05 Te-131 1.39E-12 7.44E-13 4.49E-13 1.17E-12 5.46E-12 1.74E-07 2.30E-09 9-29 VER 29 VEGP ODCM Table 9-10 (contd). Inhalation Dose Factors for the Adult Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 3.25E-08 2.69E-08 2.02E-08 2.37E-08 1.82E-07 3.60E-05 6.37E-05 1-130 5.72E-07 1.68E-06 6.60E-07 1.42E-04 2.61E-06 No Data 9.61 E-07 1-131 3.15E-06 4.47E-06 2.56E-06 1.49E-03 7.66E-06 No Data 7.85E-07 1-132 1.45E-07 4.07E-07 1.45E-07 1.43E-05 6.48E-07 No Data 5.08E-08 1-133 1.08E-06 1.85E-06 5.65E-07 2.69E-04 3.23E-06 No Data 1.11E-06 1-134 8.05E-08 2.16E-07 7.69E-08 3.73E-06 3.44E-07 No Data 1.26E-10 1-135 3.35E-07 8.73E-07 3.21E-07 5.60E-05 1.39E-06 No Data 6.56E-07 Cs-134 4.66E-05 1.06E-04 9.1OE-05 No Data 3.59E-05 1.22E-05 1.30E-06 Cs-136 4.88E-06 1.83E-05 1.38E-05 No Data 1.07E-05 1.50E-06 1.46E-06 Cs-137 5.98E-05 7.76E-05 5.35E-05 No Data 2.78E-05 9.40E-06 1.05E-06 Cs-138 4.14E-08 7.76E-08 4.05E-08 No Data 6.OOE-08 6.07E-09 2.33E-13 Ba-139 1.17E-10 8.32E-14 3.42E-12 No Data 7.78E-14 4.70E-07 1.12E-07 Ba-140 4.88E-06 6.13E-09 3.21E-07 No Data 2.09E-09 1.59E-04 2.73E-05 Ba-141 1.25E-11 9.41E-15 4.20E-13 No Data 8.75E-15 2.42E-07 1.45E-17 Ba-142 3.29E-12 3.38E-15 2.07E-13 No Data 2.86E-15 1.49E-07 1.96E-26 La-140 4.30E-08 2.17E-08 5.73E-09 No Data No Data 1.70E-05 5.73E-05 La-142 8.54E-11 3.88E-11 9.65E-12 No Data No Data 7.91E-07 2.64E-07 Ce-141 2.49E-06 1.69E-06 1.91E-07 No Data 7.83E-07 4.52E-05 1.50E-05 Ce-143 2.33E-08 1.72E-08 1.91E-09 No Data 7.60E-09 9.97E-06 2.83E-05 Ce-144 4.29E-04 1.79E-04 2.30E-05 No Data 1.06E-04 9.72E-04 1.02E-04 Pr-143 1.17E-06 4.69E-07 5.80E-08 No Data 2.70E-07 3.51E-05 2.50E-05 Pr-144 3.76E-12 1.56E-12 1.91E-13 No Data 8.81E-13 1.27E-07 2.69E-18 Nd-147 6.59E-07 7.62E-07 4.56E-08 No Data 4.45E-07 2.76E-05 2.16E-05 W-187 1.06E-09 8.85E-10 3.10E-10 No Data No Data 3.63E-06 1.94E-05 Np-239 2.87E-08 2.82E-09 1.55E-09 No Data 8.75E-09 4.70E-06 1.49E-05 9-30 VER 29 VEGP ODCM Table 9-11. Ingestion Dose Factors for the Infant Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI H-3 No Data 3.08E-07 3.08E-07 3.08E-07 3.08E-07 3.08E-07 3.08E-07 C-14 2.37E-05 5.06E-06 5.06E-06 5.06E-06 5.06E-06 5.06E-06 5.06E-06 Na-24 1.01E-05 1.01E-05 1.01E-05 1.01E-05 1.01E-05 1.01E-05 1.01E-05 P-32 1.70E-03 1.OOE-04 6.59E-05 No Data No Data No Data 2.30E-05 Cr-51 No Data No Data 1.41E-08 9.20E-09 2.01E-09 1.79E-08 4.11E-07 Mn-54 No Data 1.99E-05 4.51E-06 No Data 4.41 E-06 No Data 7.31E-06 Mn-56 No Data 8.18E-07 1.41 E-07 No Data 7.03E-07 No Data 7.43E-05 Fe-55 1.39E-05 8.98E-06 2.40E-06 No Data No Data 4.39E-06 1.14E-06 Fe-59 3.08E-05 5.38E-05 2.12E-05 No Data No Data 1.59E-05 2.57E-05 Co-58 No Data 3.60E-06 8.98E-06 No Data No Data No Data 8.97E-06 Co-60 No Data 1.08E-05 2.55E-05 No Data No Data No Data 2.57E-05 Ni-63 6.34E-04 3.92E-05 2.20E-05 No Data No Data No Data 1.95E-06 Ni-65 4.70E-06 5.32E-07 2.42E-07 No Data No Data No Data 4.05E-05 Cu-64 No Data 6.09E-07 2.82E-07 No Data 1.03E-06 No Data 1.25E-05 Zn-65 1.84E-05 6.31E-05 2.91E-05 No Data 3.06E-05 No Data 5.33E-05 Zn-69 9.33E-08 1.68E-07 1.25E-08 No Data 6.98E-08 No Data 1.37E-05 Br-83 No Data No Data 3.63E-07 No Data No Data No Data No Data Br-84 No Data No Data 3.82E-07 No Data No Data No Data No Data Br-85 No Data No Data 1.94E-08 No Data No Data No Data No Data Rb-86 No Data 1.70E-04 8.40E-05 No Data No Data No Data 4.35E-06 Rb-88 No Data 4.98E-07 2.73E-07 No Data No Data No Data 4.85E-07 Rb-89 No Data 2.86E-07 1.97E-07 No Data No Data No Data 9.74E-08 Sr-89 2.51E-03 No Data 7.20E-05 No Data No Data No Data 5.16E-05 Sr-90 1.85E-02 No Data 4.71 E-03 No Data No Data No Data 2.31E-04 Sr-91 5.OOE-05 No Data 1.81 E-06 No Data No Data No Data 5.92E-05 All values are in (mrem/pCi ingested). They are obtained from Reference 3 (Table E-14). Neither Reference 2 nor Reference 3 contains data for Rh-105, Sb-124, or Sb-125.9-31 VER 29 VEGP ODCM Table 9-11 (contd). Ingestion Dose Factors for the Infant Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 1.92E-05 No Data 7.13E-07 No Data No Data No Data 2.07E-04 Y-90 8.69E-08 No Data 2.33E-09 No Data No Data No Data 1.20E-04 Y-91m 8.10E-10 No Data 2.76E-11 No Data No Data No Data 2.70E-06 Y-91 1.13E-06 No Data 3.01E-08 No Data No Data No Data 8.1OE-05 Y-92 7.65E-09 No Data 2.15E-10 No Data No Data No Data 1.46E-04 Y-93 2.43E-08 No Data 6.62E-10 No Data No Data No Data 1.92E-04 Zr-95 2.06E-07 5.02E-08 3.56E-08 No Data 5.41 E-08 No Data 2.50E-05 Zr-97 1.48E-08 2.54E-09 1.16E-09 No Data 2.56E-09 No Data 1.62E-04 Nb-95 4.20E-08 1.73E-08 1.OOE-08 No Data 1.24E-08 No Data 1.46E-05 Mo-99 No Data 3.40E-05 6.63E-06 No Data 5.08E-05 No Data 1.12E-05 Tc-99m 1.92E-09 3.96E-09 5.1OE-08 No Data 4.26E-08 2.07E-09 1.15E-06 Tc-101 2.27E-09 2.86E-09 2.83E-08 No Data 3.40E-08 1.56E-09 4.86E-07 Ru-103 1.48E-06 No Data 4.95E-07 No Data 3.08E-06 No Data 1.80E-05 Ru-105 1.36E-07 No Data 4.58E-08 No Data 1.OOE-06 No Data 5.41 E-05 Ru-106 2.41 E-05 No Data 3.01E-06 No Data 2.85E-05 No Data 1.83E-04 Rh-105 No Data No Data No Data No Data No Data No Data No Data Ag-110m 9.96E-07 7.27E-07 4.81E-07 No Data 1.04E-06 No Data 3.77E-05 Sb-124 No Data No Data No Data No Data No Data No Data No Data Sb-125 No Data No Data No Data No Data No Data No Data No Data Te-125m 2.33E-05 7.79E-06 3.15E-06 7.84E-06 No Data No Data 1.11E-05 Te-127m 5.85E-05 1.94E-05 7.08E-06 1.69E-05 1.44E-04 No Data 2.36E-05 Te-127 1.OOE-06 3.35E-07 2.15E-07 8.14E-07 2.44E-06 No Data 2.1OE-05 Te-129m 1.OOE-04 3.43E-05 1.54E-05 3.84E-05 2.50E-04 No Data 5.97E-05 Te-129 2.84E-07 9.79E-08 6.63E-08 2.38E-07 7.07E-07 No Data 2.27E-05 Te-131m 1.52E-05 6.12E-06 5.05E-06 1.24E-05 4.21E-05 No Data 1.03E-04 Te-131 1.76E-07 6.50E-08 4.94E-08 1.57E-07 4.50E-07 No Data 7.11E-06 9-32 VER 29 VEGP ODCM Table 9-11 (contd). Ingestion Dose Factors for the Infant Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 2.08E-05 1.03E-05 9.61E-06 1.52E-05 6.44E-05 No Data 3.81 E-05 1-130 6.OOE-06 1.32E-05 5.30E-06 1.48E-03 1.45E-05 No Data 2.83E-06 1-131 3.59E-05 4.23E-05 1.86E-05 1.39E-02 4.94E-05 No Data 1.51E-06 1-132 1.66E-06 3.37E-06 1.20E-06 1.58E-04 3.76E-06 No Data 2.73E-06 1-133 1.25E-05 1.82E-05 5.33E-06 3.31E-03 2.14E-05 No Data 3.08E-06 1-134 8.69E-07 1.78E-06 6.33E-07 4.15E-05 1.99E-06 No Data 1.84E-06 1-135 3.64E-06 7.24E-06 2.64E-06 6.49E-04 8.07E-06 No Data 2.62E-06 Cs-134 3.77E-04 7.03E-04 7.1OE-05 No Data 1.81E-04 7.42E-05 1.91 E-06 Cs-136 4.59E-05 1.35E-04 5.04E-05 No Data 5.38E-05 1.1OE-05 2.05E-06 Cs-137 5.22E-04 6.11E-04 4.33E-05 No Data 1.64E-04 6.64E-05 1.91E-06 Cs-138 4.81E-07 7.82E-07 3.79E-07 No Data 3.90E-07 6.09E-08 1.25E-06 Ba-139 8.81E-07 5.84E-10 2.55E-08 No Data 3.51E-10 3.54E-10 5.58E-05 Ba-140 1.71E-04 1.71E-07 8.81E-06 No Data 4.06E-08 1.05E-07 4.20E-05 Ba-141 4.25E-07 2.91E-10 1.34E-08 No Data 1.75E-10 1.77E-10 5.19E-06 Ba-142 1.84E-07 1.53E-10 9.06E-09 No Data 8.81E-11 9.26E-11 7.59E-07 La-140 2.11E-08 8.32E-09 2.14E-09 No Data No Data No Data 9.77E-05 La-142 1.1OE-09 4.04E-10 9.67E-11 No Data No Data No Data 6.86E-05 Ce-141 7.87E-08 4.80E-08 5.65E-09 No Data 1.48E-08 No Data 2.48E-05 Ce-143 1.48E-08 9.82E-06 1.12E-09 No Data 2.86E-09 No Data 5.73E-05 Ce-144 2.98E-06 1.22E-06 1.67E-07 No Data 4.93E-07 No Data 1.71E-04 Pr-143 8.13E-08 3.04E-08 4.03E-09 No Data 1.13E-08 No Data 4.29E-05 Pr-144 2.74E-10 1.06E-10 1.38E-11 No Data 3.84E-11 No Data 4.93E-06 Nd-147 5.53E-08 5.68E-08 3.48E-09 No Data 2.19E-08 No Data 3.60E-05 W-187 9.03E-07 6.28E-07 2.17E-07 No Data No Data No Data 3.69E-05 Np-239 1.11E-08 9.93E-10 5.61E-10 No Data 1.98E-09 No Data 2.87E-05 9-33 VER 29 VEGP ODCM Table 9-12. Ingestion Dose Factors for the Child Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 No Data 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 C-14 1.21E-05 2.42E-06 2.42E-06 2.42E-06 2.42E-06 2.42E-06 2.42E-06 Na-24 5.80E-06 5.80E-06 5.80E-06 5.80E-06 5.80E-06 5.80E-06 5.80E-06 P-32 8.25E-04 3.86E-05 3.18E-05 No Data No Data No Data 2.28E-05 Cr-51 No Data No Data 8.90E-09 4.94E-09 1.35E-09 9.02E-09 4.72E-07 Mn-54 No Data 1.07E-05 2.85E-06 No Data 3.OOE-06 No Data 8.98E-06 Mn-56 No Data 3.34E-07 7.54E-08 No Data 4.04E-07 No Data 4.84E-05 Fe-55 1.15E-05 6.1OE-06 1.89E-06 No Data No Data 3.45E-06 1.13E-06 Fe-59 1.65E-05 2.67E-05 1.33E-05 No Data No Data 7.74E-06 2.78E-05 Co-58 No Data 1.80E-06 5.51 E-06 No Data No Data No Data 1.05E-05 Co-60 No Data 5.29E-06 1.56E-05 No Data No Data No Data 2.93E-05 Ni-63 5.38E-04 2.88E-05 1.83E-05 No Data No Data No Data 1.94E-06 Ni-65 2.22E-06 2.09E-07 1.22E-07 No Data No Data No Data 2.56E-05 Cu-64 No Data 2.45E-07 1.48E-07 No Data 5.92E-07 No Data 1.15E-05 Zn-65 1.37E-05 3.65E-05 2.27E-05 No Data 2.30E-05 No Data 6.41 E-06 Zn-69 4.38E-08 6.33E-08 5.85E-09 No Data 3.84E-08 No Data 3.99E-06 Br-83 No Data No Data 1.71 E-07 No Data No Data No Data No Data Br-84 No Data No Data 1.98E-07 No Data No Data No Data No Data Br-85 No Data No Data 9.12E-09 No Data No Data No Data No Data Rb-86 No Data 6.70E-05 4.12E-05 No Data No Data No Data 4.31 E-06 Rb-88 No Data 1.90E-07 1.32E-07 No Data No Data No Data 9.32E-09 Rb-89 No Data 1.1 7E-07 1.04E-07 No Data No Data No Data 1.02E-09 Sr-89 1.32E-03 No Data 3.77E-05 No Data No Data No Data 5.11 E-05 Sr-90 1.70E-02 No Data 4.31 E-03 No Data No Data No Data 2.29E-04 Sr-91 2.40E-05 No Data 9.06E-07 No Data No Data No Data 5.30E-05 All values are in (mrem/pCi ingested). They are obtained from Reference 3 (Table E-13). Neither Reference 2 nor Reference 3 contains data for Rh-105, Sb-124, or Sb-125.9-34 VER 29 VEGP ODCM Table 9-12 (contd). Ingestion Dose Factors for the Child Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 9.03E-06 No Data 3.62E-07 No Data No Data No Data 1.71 E-04 Y-90 4.11E-08 No Data 1.10E-09 No Data No Data No Data 1.17E-04 Y-91m 3.82E-10 No Data 1.39E-11 No Data No Data No Data 7.48E-07 Y-91 6.02E-07 No Data 1.61 E-08 No Data No Data No Data 8.02E-05 Y-92 3.60E-09 No Data 1.03E-10 No Data No Data No Data 1.04E-04 Y-93 1.14E-08 No Data 3.13E-10 No Data No Data No Data 1.70E-04 Zr-95 1.16E-07 2.55E-08 2.27E-08 No Data 3.65E-08 No Data 2.66E-05 Zr-97 6.99E-09 1.01E-09 5.96E-10 No Data 1.45E-09 No Data 1.53E-04 Nb-95 2.25E-08 8.76E-09 6.26E-09 No Data 8.23E-09 No Data 1.62E-05 Mo-99 No Data 1.33E-05 3.29E-06 No Data 2.84E-05 No Data 1.1 OE-05 Tc-99m 9.23E-10 1.81E-09 3.OOE-08 No Data 2.63E-08 9.19E-10 1.03E-06 Tc-101 1.07E-09 1.12E-09 1.42E-08 No Data 1.91E-08 5.92E-10 3.56E-09 Ru-103 7.31 E-07 No Data 2.81E-07 No Data 1.84E-06 No Data 1.89E-05 Ru-105 6.45E-08 No Data 2.34E-08 No Data 5.67E-07 No Data 4.21E-05 Ru-106 1.17E-05 No Data 1.46E-06 No Data 1.58E-05 No Data 1.82E-04 Rh-105 No Data No Data No Data No Data No Data No Data No Data Ag-110m 5.39E-07 3.64E-07 2.91E-07 No Data 6.78E-07 No Data 4.33E-05 Sb-124 No Data No Data No Data No Data No Data No Data No Data Sb-125 No Data No Data No Data No Data No Data No Data No Data Te-125m 1.14E-05 3.09E-06 1.52E-06 3.20E-06 No Data No Data 1.10E-05 Te-127m 2.89E-05 7.78E-06 3.43E-06 6.91E-06 8.24E-05 No Data 2.34E-05 Te-127 4.71 E-07 1.27E-07 1.01E-07 3.26E-07 1.34E-06 No Data 1.84E-05 Te-129m 4.87E-05 1.36E-05 7.56E-06 1.57E-05 1.43E-04 No Data 5.94E-05 Te-129 1.34E-07 3.74E-08 3.18E-08 9.56E-08 3.92E-07 No Data 8.34E-06 Te-131m 7.20E-06 2.49E-06 2.65E-06 5.12E-06 2.41E-05 No Data 1.01E-04 Te-131 8.30E-08 2.53E-08 2.47E-08 6.35E-08 2.51E-07 No Data 4.36E-07 9-35 VER 29 VEGP ODCM Table 9-12 (contd). Ingestion Dose Factors for the Child Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 1.01E-05 4.47E-06 5.40E-06 6.51E-06 4.15E-05 No Data 4.50E-05 1-130 2.92E-06 5.90E-06 3.04E-06 6.50E-04 8.82E-06 No Data 2.76E-06 1-131 1.72E-05 1.73E-05 9.83E-06 5.72E-03 2.84E-05 No Data 1.54E-06 1-132 8.OOE-07 1.47E-06 6.76E-07 6.82E-05 2.25E-06 No Data 1.73E-06 1-133 5.92E-06 7.32E-06 2.77E-06 1.36E-03 1.22E-05 No Data 2.95E-06 1-134 4.19E-07 7.78E-07 3.58E-07 1.79E-05 1.19E-06 No Data 5.16E-07 1-135 1.75E-06 3.15E-06 1.49E-06 2.79E-04 4.83E-06 No Data 2.40E-06 Cs-134 2.34E-04 3.84E-04 8.1OE-05 No Data 1.19E-04 4.27E-05 2.07E-06 Cs-136 2.35E-05 6.46E-05 4.18E-05 No Data 3.44E-05 5.13E-06 2.27E-06 Cs-137 3.27E-04 3.13E-04 4.62E-05 No Data 1.02E-04 3.67E-05 1.96E-06 Cs-138 2.28E-07 3.17E-07 2.01E-07 No Data 2.23E-07 2.40E-08 1.46E-07 Ba-139 4.14E-07 2.21E-10 1.20E-08 No Data 1.93E-10 1.30E-10 2.39E-05 Ba-140 8.31E-05 7.28E-08 4.85E-06 No Data 2.37E-08 4.34E-08 4.21E-05 Ba-141 2.OOE-07 1.12E-10 6.51E-09 No Data 9.69E-11 6.58E-10 1.14E-07 Ba-142 8.74E-08 6.29E-11 4.88E-09 No Data 5.09E-11 3.70E-11 1.14E-09 La-140 1.01E-08 3.53E-09 1.19E-09 No Data No Data No Data 9.84E-05 La-142 5.24E-10 1.67E-10 5.23E-11 No Data No Data No Data 3.31E-05 Ce-141 3.97E-08 1.98E-08 2.94E-09 No Data 8.68E-09 No Data 2.47E-05 Ce-143 6.99E-09 3.79E-06 5.49E-10 No Data 1.59E-09 No Data 5.55E-05 Ce-144 2.08E-06 6.52E-07 1.11E-07 No Data 3.61E-07 No Data 1.70E-04 Pr-143 3.93E-08 1.18E-08 1.95E-09 No Data 6.39E-09 No Data 4.24E-05 Pr-144 1.29E-10 3.99E-11 6.49E-12 No Data 2.11E-11 No Data 8.59E-08 Nd-147 2.79E-08 2.26E-08 1.75E-09 No Data 1.24E-08 No Data 3.58E-05 W-187 4.29E-07 2.54E-07 1.14E-07 No Data No Data No Data 3.57E-05 Np-239 5.25E-09 3.77E-10 2.65E-10 No Data 1.09E-09 No Data 2.79E-05 9-36 VER 29 VEGP ODCM Table 9-13. Ingestion Dose Factors for the Teenager Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 No Data 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 1.06E-07 C-14 4.06E-06 8.12E-07 8.12E-07 8.12E-07 8.12E-07 8.12E-07 8.12E-07 Na-24 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 P-32 2.76E-04 1.71 E-05 1.07E-05 No Data No Data No Data 2.32E-05 Cr-51 No Data No Data 3.60E-09 2.OOE-09 7.89E-10 5.14E-09 6.05E-07 Mn-54 No Data 5.90E-06 1.17E-06 No Data 1.76E-06 No Data 1.21E-05 Mn-56 No Data 1.58E-07 2.81E-08 No Data 2.OOE-07 No Data 1.04E-05 Fe-55 3.78E-06 2.68E-06 6.25E-07 No Data No Data 1.70E-06 1.16E-06 Fe-59 5.87E-06 1.37E-05 5.29E-06 No Data No Data 4.32E-06 3.24E-05 Co-58 No Data 9.72E-07 2.24E-06 No Data No Data No Data 1.34E-05 Co-60 No Data 2.81E-06 6.33E-06 No Data No Data No Data 3.66E-05 Ni-63 1.77E-04 1.25E-05 6.OOE-06 No Data No Data No Data 1.99E-06 Ni-65 7.49E-07 9.57E-08 4.36E-08 No Data No Data No Data 5.19E-06 Cu-64 No Data 1.15E-07 5.41E-08 No Data 2.91 E-07 No Data 8.92E-06 Zn-65 5.76E-06 2.OOE-05 9.33E-06 No Data 1.28E-05 No Data 8.47E-06 Zn-69 1.47E-08 2.80E-08 1.96E-09 No Data 1.83E-08 No Data 5.16E-08 Br-83 No Data No Data 5.74E-08 No Data No Data No Data No Data Br-84 No Data No Data 7.22E-08 No Data No Data No Data No Data Br-85 No Data No Data 3.05E-09 No Data No Data No Data No Data Rb-86 No Data 2.98E-05 1.40E-05 No Data No Data No Data 4.41 E-06 Rb-88 No Data 8.52E-08 4.54E-08 No Data No Data No Data 7.30E-15 Rb-89 No Data 5.50E-08 3.89E-08 No Data No Data No Data 8.43E-17 Sr-89 4.40E-04 No Data 1.26E-05 No Data No Data No Data 5.24E-05 Sr-90 8.30E-03 No Data 2.05E-03 No Data No Data No Data 2.33E-04 Sr-91 8.07E-06 No Data 3.21 E-07 No Data No Data No Data 3.66E-05 All values are in (mrem/pCi ingested). They are obtained from Reference 3 (Table E-12). Neither Reference 2 nor Reference 3 contains data for Rh-1 05, Sb-1 24, or Sb-1 25.9-37 VER 29 VEGP ODCM Table 9-13 (contd). Ingestion Dose Factors for the Teenager Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 3.05E-06 No Data 1.30E-07 No Data No Data No Data 7.77E-05 Y-90 1.37E-08 No Data 3.69E-10 No Data No Data No Data 1.13E-04 Y-91m 1.29E-10 No Data 4.93E-12 No Data No Data No Data 6.09E-09 Y-91 2.01E-07 No Data 5.39E-09 No Data No Data No Data 8.24E-05 Y-92 1.21E-09 No Data 3.50E-11 No Data No Data No Data 3.32E-05 Y-93 3.83E-09 No Data 1.05E-10 No Data No Data No Data 1.17E-04 Zr-95 4.12E-08 1.30E-08 8.94E-09 No Data 1.91 E-08 No Data 3.OOE-05 Zr-97 2.37E-09 4.69E-10 2.16E-10 No Data 7.11E-10 No Data 1.27E-04 Nb-95 8.22E-09 4.56E-09 2.51E-09 No Data 4.42E-09 No Data 1.95E-05 Mo-99 No Data 6.03E-06 1.15E-06 No Data 1.38E-05 No Data 1.08E-05 Tc-99m 3.32E-10 9.26E-10 1.20E-08 No Data 1.38E-08 5.14E-10 6.08E-07 Tc-101 3.60E-10 5.12E-10 5.03E-09 No Data 9.26E-09 3.12E-10 8.75E-17 Ru-103 2.55E-07 No Data 1.09E-07 No Data 8.99E-07 No Data 2.13E-05 Ru-105 2.18E-08 No Data 8.46E-09 No Data 2.75E-07 No Data 1.76E-05 Ru-106 3.92E-06 No Data 4.94E-07 No Data 7.56E-06 No Data 1.88E-04 Rh-1 05 No Data No Data No Data No Data No Data No Data No Data Ag-110m 2.05E-07 1.94E-07 1.18E-07 No Data 3.70E-07 No Data 5.45E-05 Sb-124 No Data No Data No Data No Data No Data No Data No Data Sb-1 25 No Data No Data No Data No Data No Data No Data No Data Te-125m 3.83E-06 1.38E-06 5.12E-07 1.07E-06 No Data No Data 1.13E-05 Te-127m 9.67E-06 3.43E-06 1.15E-06 2.30E-06 3.92E-05 No Data 2.41E-05 Te-127 1.58E-07 5.60E-08 3.40E-08 1.09E-07 6.40E-07 No Data 1.22E-05 Te-129m 1.63E-05 6.05E-06 2.58E-06 5.26E-06 6.82E-05 No Data 6.12E-05 Te-129 4.48E-08 1.67E-08 1.09E-08 3.20E-08 1.88E-07 No Data 2.45E-07 Te-131m 2.44E-06 1.17E-06 9.76E-07 1.76E-06 1.22E-05 No Data 9.39E-05 Te-131 2.79E-08 1.15E-08 8.72E-09 2.15E-08 1.22E-07 No Data 2.29E-09 9-38 VER 29 VEGP ODCM Table 9-13 (contd). Ingestion Dose Factors for the Teenager Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 3.49E-06 2.21E-06 2.08E-06 2.33E-06 2.12E-05 No Data 7.OOE-05 1-130 1.03E-06 2.98E-06 1.19E-06 2.43E-04 4.59E-06 No Data 2.29E-06 1-131 5.85E-06 8.19E-06 4.40E-06 2.39E-03 1.41E-05 No Data 1.62E-06 1-132 2.79E-07 7.30E-07 2.62E-07 2.46E-05 1.15E-06 No Data 3.18E-07 1-133 2.01E-06 3.41E-06 1.04E-06 4.76E-04 5.98E-06 No Data 2.58E-06 1-134 1.46E-07 3.87E-07 1.39E-07 6.45E-06 6.1OE-07 No Data 5.1OE-09 1-135 6.1OE-07 1.57E-06 5.82E-07 1.01E-04 2.48E-06 No Data 1.74E-06 Cs-134 8.37E-05 1.97E-04 9.14E-05 No Data 6.26E-05 2.39E-05 2.45E-06 Cs-136 8.59E-06 3.38E-05 2.27E-05 No Data 1.84E-05 2.90E-06 2.72E-06 Cs-137 1.12E-04 1.49E-04 5.19E-05 No Data 5.07E-05 1.97E-05 2.12E-06 Cs-138 7.76E-08 1.49E-07 7.45E-08 No Data 1.1OE-07 1.28E-08 6.76E-11 Ba-139 1.39E-07 9.78E-11 4.05E-09 No Data 9.22E-11 6.74E-11 1.24E-06 Ba-140 2.84E-05 3.48E-08 1.83E-06 No Data 1.18E-08 2.34E-08 4.38E-05 Ba-141 6.71E-08 5.01E-11 2.24E-09 No Data 4.65E-11 3.43E-11 1.43E-13 Ba-142 2.99E-08 2.99E-11 1.84E-09 No Data 2.53E-11 1.99E-11 9.18E-20 La-140 3.48E-09 1.71E-09 4.55E-10 No Data No Data No Data 9.82E-05 La-142 1.79E-10 7.95E-11 1.98E-11 No Data No Data No Data 2.42E-06 Ce-141 1.33E-08 8.88E-09 1.02E-09 No Data 4.18E-09 No Data 2.54E-05 Ce-143 2.35E-09 1.71E-06 1.91E-10 No Data 7.67E-10 No Data 5.14E-05 Ce-144 6.96E-07 2.88E-07 3.74E-08 No Data 1.72E-07 No Data 1.75E-04 Pr-143 1.31E-08 5.23E-09 6.52E-10 No Data 3.04E-09 No Data 4.31E-05 Pr-144 4.30E-11 1.76E-11 2.18E-12 No Data 1.01 E-11 No Data 4.74E-14 Nd-147 9.38E-09 1.02E-08 6.11E-10 No Data 5.99E-09 No Data 3.68E-05 W-187 1.46E-07 1.19E-07 4.17E-08 No Data No Data No Data 3.22E-05 Np-239 1.76E-09 1.66E-10 9.22E-11 No Data 5.21E-10 No Data 2.67E-05 9-39 VER 29 VEGP ODCM Table 9-14. Ingestion Dose Factors for the Adult Age Group Nuclide Bone Liver T. Body Thyroid Kidney Lung GI-LLI H-3 No Data 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 1.05E-07 C-14 2.84E-06 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 Na-24 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 P-32 1.93E-04 1.20E-05 7.46E-06 No Data No Data No Data 2.17E-05 Cr-51 No Data No Data 2.66E-09 1.59E-09 5.86E-10 3.53E-09 6.69E-07 Mn-54 No Data 4.57E-06 8.72E-07 No Data 1.36E-06 No Data 1.40E-05 Mn-56 No Data 1.15E-07 2.04E-08 No Data 1.46E-07 No Data 3.67E-06 Fe-55 2.75E-06 1.90E-06 4.43E-07 No Data No Data 1.06E-06 1.09E-06 Fe-59 4.34E-06 1.02E-05 3.91 E-06 No Data No Data 2.85E-06 3.40E-05 Co-58 No Data 7.45E-07 1.67E-06 No Data No Data No Data 1.51 E-05 Co-60 No Data 2.14E-06 4.72E-06 No Data No Data No Data 4.02E-05 Ni-63 1.30E-04 9.01E-06 4.36E-06 No Data No Data No Data 1.88E-06 Ni-65 5.28E-07 6.86E-08 3.13E-08 No Data No Data No Data 1.74E-06 Cu-64 No Data 8.33E-08 3.91E-08 No Data 2.1OE-07 No Data 7.1OE-06 Zn-65 4.84E-06 1.54E-05 6.96E-06 No Data 1.03E-05 No Data 9.70E-06 Zn-69 1.03E-08 1.97E-08 1.37E-09 No Data 1.28E-08 No Data 2.96E-09 Br-83 No Data No Data 4.02E-08 No Data No Data No Data 5.79E-08 Br-84 No Data No Data 5.21E-08 No Data No Data No Data 4.09E-13 Br-85 No Data No Data 2.14E-09 No Data No Data No Data No Data Rb-86 No Data 2.11 E-05 9.83E-06 No Data No Data No Data 4.16E-06 Rb-88 No Data 6.05E-08 3.21E-08 No Data No Data No Data 8.36E-19 Rb-89 No Data 4.01E-08 2.82E-08 No Data No Data No Data 2.33E-21 Sr-89 3.08E-04 No Data 8.84E-06 No Data No Data No Data 4.94E-05 Sr-90 7.58E-03 No Data 1.86E-03 No Data No Data No Data 2.19E-04 Sr-91 5.67E-06 No Data 2.29E-07 No Data No Data No Data 2.70E-05 All values are in (mrem/pCi ingested). They are obtained from Reference 3 (Table E-1 1), except as follows: Reference 2 (Table A-3) for Rh-1 05, Sb-1 24, and Sb-125.9-40 VER 29 VEGP ODCM Table 9-14 (contd). Ingestion Dose Factors for the Adult Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Sr-92 2.15E-06 No Data 9.30E-08 No Data No Data No Data 4.26E-05 Y-90 9.62E-09 No Data 2.58E-10 No Data No Data No Data 1.02E-04 Y-91m 9.09E-11 No Data 3.52E-12 No Data No Data No Data 2.67E-10 Y-91 1.41E-07 No Data 3.77E-09 No Data No Data No Data 7.76E-05 Y-92 8.45E-10 No Data 2.47E-11 No Data No Data No Data 1.48E-05 Y-93 2.68E-09 No Data 7.40E-11 No Data No Data No Data 8.50E-05 Zr-95 3.04E-08 9.75E-09 6.60E-09 No Data 1.53E-08 No Data 3.09E-05 Zr-97 1.68E-09 3.39E-10 1.55E-10 No Data 5.12E-10 No Data 1.05E-04 Nb-95 6.22E-09 3.46E-09 1.86E-09 No Data 3.42E-09 No Data 2.1OE-05 Mo-99 No Data 4.31E-06 8.20E-07 No Data 9.76E-06 No Data 9.99E-06 Tc-99m 2.47E-10 6.98E-10 8.89E-09 No Data 1.06E-08 3.42E-10 4.13E-07 Tc-101 2.54E-10 3.66E-10 3.59E-09 No Data 6.59E-09 1.87E-10 1.1OE-21 Ru-103 1.85E-07 No Data 7.97E-08 No Data 7.06E-07 No Data 2.16E-05 Ru-105 1.54E-08 No Data 6.08E-09 No Data 1.99E-07 No Data 9.42E-06 Ru-106 2.75E-06 No Data 3.48E-07 No Data 5.31E-06 No Data 1.78E-04 Rh-105 1.22E-07 8.86E-08 5.83E-08 No Data 3.76E-07 No Data 1.41 E-05 Ag-110m 1.60E-07 1.48E-07 8.79E-08 No Data 2.91E-07 No Data 6.04E-05 Sb-124 2.81E-06 5.30E-08 1.11E-06 6.79E-09 No Data 2.18E-06 7.95E-05 Sb-125 2.23E-06 2.40E-08 4.48E-07 1.98E-09 No Data 2.33E-04 1.97E-05 Te-125m 2.68E-06 9.71E-07 3.59E-07 8.06E-07 1.09E-05 No Data 1.07E-05 Te-127m 6.77E-06 2.42E-06 8.25E-07 1.73E-06 2.75E-05 No Data 2.27E-05 Te-127 1.1OE-07 3.95E-08 2.38E-08 8.15E-08 4.48E-07 No Data 8.68E-06 Te-129m 1.15E-05 4.29E-06 1.82E-06 3.95E-06 4.80E-05 No Data 5.79E-05 Te-129 3.14E-08 1.18E-08 7.65E-09 2.41E-08 1.32E-07 No Data 2.37E-08 Te-131m 1.73E-06 8.46E-07 7.05E-07 1.34E-06 8.57E-06 No Data 8.40E-05 Te-131 1.97E-08 8.23E-09 6.22E-09 1.62E-08 8.63E-08 No Data 2.79E-09 9-41 VER 29 VEGP ODCM Table 9-14 (contd). Ingestion Dose Factors for the Adult Age Group Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Te-132 2.52E-06 1.63E-06 1.53E-06 1.80E-06 1.57E-05 No Data 7.71 E-05 1-130 7.56E-07 2.23E-06 8.80E-07 1.89E-04 3.48E-06 No Data 1.92E-06 1-131 4.16E-06 5.95E-06 3.41E-06 1.95E-03 1.02E-05 No Data 1.57E-06 1-132 2.03E-07 5.43E-07 1.90E-07 1.90E-05 8.65E-07 No Data 1.02E-07 1-133 1.42E-06 2.47E-06 7.53E-07 3.63E-04 4.31E-06 No Data 2.22E-06 1-134 1.06E-07 2.88E-07 1.03E-07 4.99E-06 4.58E-07 No Data 2.51 E-10 1-135 4.43E-07 1.16E-06 4.28E-07 7.65E-05 1.86E-06 No Data 1.31E-06 Cs-134 6.22E-05 1.48E-04 1.21E-04 No Data 4.79E-05 1.59E-05 2.59E-06 Cs-136 6.51E-06 2.57E-05 1.85E-05 No Data 1.43E-05 1.96E-06 2.92E-06 Cs-137 7.97E-05 1.09E-04 7.14E-05 No Data 3.70E-05 1.23E-05 2.11E-06 Cs-138 5.52E-08 1.09E-07 5.40E-08 No Data 8.01E-08 7.91E-09 4.65E-13 Ba-139 9.70E-08 6.91E-11 2.84E-09 No Data 6.46E-11 3.92E-11 1.72E-07 Ba-140 2.03E-05 2.55E-08 1.33E-06 No Data 8.67E-09 1.46E-08 4.18E-05 Ba-141 4.71E-08 3.56E-11 1.59E-09 No Data 3.31E-11 2.02E-11 2.22E-17 Ba-142 2.13E-08 2.19E-11 1.34E-09 No Data 1.85E-11 1.24E-11 3.OOE-26 La-140 2.50E-09 1.26E-09 3.33E-10 No Data No Data No Data 9.25E-05 La-142 1.28E-10 5.82E-11 1.45E-11 No Data No Data No Data 4.25E-07 Ce-141 9.36E-09 6.33E-09 7.18E-10 No Data 2.94E-09 No Data 2.42E-05 Ce-143 1.65E-09 1.22E-06 1.35E-10 No Data 5.37E-10 No Data 4.56E-05 Ce-144 4.88E-07 2.04E-07 2.62E-08 No Data 1.21E-07 No Data 1.65E-04 Pr-143 9.20E-09 3.69E-09 4.56E-10 No Data 2.13E-09 No Data 4.03E-05 Pr-144 3.01 E-11 1.25E-11 1.53E-12 No Data 7.05E-12 No Data 4.33E-18 Nd-147 6.29E-09 7.27E-09 4.35E-10 No Data 4.25E-09 No Data 3.49E-05 W-187 1.03E-07 8.61E-08 3.01E-08 No Data No Data No Data 2.82E-05 Np-239 1.19E-09 1.17E-10 6.45E-11 No Data 3.65E-10 No Data 2.40E-05 9-42 VER 29 9-42 VER 29 VEGP ODCM Table 9-15.External Dose Factors for Standing on Contaminated Ground Nuclide T. Body Skin H-3 0.00 0.00 C-14 0.00 0.00 Na-24 2.50E-08 2.90E-08 P-32 0.00 0.00 Cr-51 2.20E-10 2.60E-10 Mn-54 5.80E-09 6.80E-09 Mn-56 1.10E-08 1.30E-08 Fe-55 0.00 0.00 Fe-59 8.OOE-09 9.40E-09 Co-58 7.OOE-09 8.20E-09 Co-60 1.70E-08 2.OOE-08 Ni-63 0.00 0.00 Ni-65 3.70E-09 4.30E-09 Cu-64 1.50E-09 1.70E-09 Zn-65 4.OOE-09 4.60E-09 Zn-69 0.00 0.00 Br-83 6.40E-1 1 9.30E-1 1 Br-84 1.20E-08 1.40E-08 Br-85 0.00 0.00 Rb-86 6.30E-10 7.20E-10 Rb-88 3.50E-09 4.OOE-09 Rb-89 1.50E-08 1.80E-08 Sr-89 5.60E-13 6.50E-13 Sr-90 0.00 0.00 Nuclide T. Body Skin Sr-91 7.1OE-09 8.30E-09 Sr-92 9.OOE-09 1.OOE-08 Y-90 2.20E-12 2.60E-12 Y-91 m 3.80E-09 4.40E-09 Y-91 2.40E-11 2.70E- 11 Y-92 1.60E-09 1.90E-09 Y-93 5.70E-10 7.80E-10 Zr-95 5.OOE-09 5.80E-09 Zr-97 5.50E-09 6.40E-09 Nb-95 5.1OE-09 6.OOE-09 Mo-99 1.90E-09 2.20E-09 Tc-99m 9.60E-10 1.1OE-09 Tc-101 2.70E-09 3.OOE-09 Ru-103 3.60E-09 4.20E-09 Ru-105 4.50E-09 5.1OE-09 Ru-106 1.50E-09 1.80E-09 Rh-105 6.60E-10 7.70E-10 Ag-11im 1.80E-08 2.1OE-08 Sb-124 1.30E-08 1.50E-08 Sb-125 3.1OE-09 3.50E-09 Te-125m 3.50E-11 4.80E-11 Te-127m 1.10E-12 1.30E-12 Te-127 1.O0E-11 1.10E-11 Te-129m 7.70E-10 9.OOE-10 All values are in (mrem/h) per (pCi/m 2). They are obtained from Reference 3 (Table E-6), except as follows: Reference 2 (Table A-7) for Rh-105, Sb-124, and Sb-125.9-43 VER 29 VEGP ODCM Table 9-15 (contd).External Dose Factors for Standing on Contaminated Ground Nuclide T.Body Skin Te-129 7.10E-10 8.40E-10 Te-131m 8.40E-09 9.90E-09 Te-131 2.20E-09 2.60E-06 Te-132 1.70E-09 2.OOE-09 1-130 1.40E-08 1.70E-08 1-131 2.80E-09 3.40E-09 1-132 1.70E-08 2.OOE-08 1-133 3.70E-09 4.50E-09 1-134 1.60E-08 1.90E-08 1-135 1.20E-08 1.40E-08 Cs-134 1.20E-08 1.40E-08 Cs-136 1.50E-08 1.70E-08 Cs-137 4.20E-09 4.90E-09 Cs-138 2.1OE-08 2.40E-08 Ba-139 2.40E-09 2.70E-09 Ba-140 2.1OE-09 2.40E-09 Ba-141 4.30E-09 4.90E-09 Ba-142 7.90E-09 9.OOE-09 La-140 1.50E-08 1.70E-08 La-142 1.50E-08 1.80E-08 Ce-141 5.50E-10 6.20E-10 Ce-143 2.20E-09 2.50E-09 Ce-144 3.20E-10 3.70E-10 Pr-143 0.00 0.00 Pr-144 2.OOE-10 2.30E-10 Nd-147 1.00E-09 1.20E-09 W-187 3.1OE-09 3.60E-09 Np-239 9.50E-10 1.1OE-09 9-44 VER 29 VEGP ODCM CHAPTER 10 DEFINITIONS OF EFFLUENT CONTROL TERMS The terms defined in this chapter are used in the presentation of the above chapters.These terms are shown in all capital letters to indicate that they are specifically defined.10.1 TERMS SPECIFIC TO THE ODCM The following terms are used in the ODCM, but are not found in the Technical Specifications: ACTION(S)An ACTION shall be that part of a control that prescribes remedial measures required under designated conditions. BATCH RELEASE A BATCH RELEASE is the discharge of wastes of a discrete volume. Prior to sampling for analyses, each liquid batch shall be isolated and then thoroughly mixed by a method described in the ODCM to assure representative sampling.COMPOSITE SAMPLE A COMPOSITE SAMPLE is one which contains material from multiple waste releases, in which the quantity of sample is proportional to the quantity of waste discharged, and in which the method of sampling employed results in a specimen that is representative of the wastes released. Prior to analyses, all liquid samples that are to be aliquotted for a COMPOSITE SAMPLE shall be mixed thoroughly, in order for the COMPOSITE SAMPLE to be representative of the effluent release.When assessing the consequences of a waste release at the pre-release or post-release stage, the most recent available COMPOSITE SAMPLE results for the applicable release pathway may be used.CONTINUOUS RELEASE A CONTINUOUS RELEASE is the discharge of wastes of a non-discrete volume, e.g., from a volume within a system that has an input flow during the continuous release. To be representative of the quantities and concentrations of radioactive materials in CONTINUOUS RELEASES of liquid effluents, samples shall be collected in proportion to the rate of flow of the effluent stream or to the quantity of liquid waste discharged. FREQUENCY NOTATION The FREQUENCY NOTATION specified for the performance of surveillance requirements shall correspond to the intervals defined below, with a maximum allowable extension not to exceed 25% of the surveillance interval.9-45 VER 29 VEGP ODCM NOTATION FREQUENCY S (Once per shift) At least once per 12 hours.D (Daily) At least once per 24 hours.W (Weekly) At least once per 7 days.M (Monthly) At least once per 31 days.Q (Quarterly) At least once per 92 days.SA (Semi-annually) At least once per 184 days.R (Refueling) At least once per 18 months.S/U (Startup) Prior to each reactor startup.NA Not applicable. P (Prior) Completed prior to each release.GASEOUS WASTE PROCESSING SYSTEM A GASEOUS WASTE PROCESSING SYSTEM shall be any system designed and installed to reduce radioactive gaseous effluents by collecting Reactor Coolant System offgases from the Reactor Coolant System and providing for delay or holdup for the purpose of reducing the total radioactivity prior to release to the environment. LIQUID RADWASTE TREATMENT SYSTEM A LIQUID RADWASTE TREATMENT SYSTEM is any system designed and installed to reduce radioactive materials in liquid effluents by systematic collection, retention, and processing through filtration, evaporation, separation and/or ion exchange treatment. This system consists of at least one collection tank, one evaporator or demineralizer system, one post-treatment tank and associated components providing for treatment flow and functional control.MAJOR CHANGES TO RADIOACTIVE WASTE TREATMENT SYSTEMS For the purposes of the ODCM, MAJOR CHANGES TO RADIOACTIVE WASTE TREATMENT SYSTEMS include the following changes to such systems: (1) Major changes in process equipment, components, structures, or effluent monitoring instrumentation as described in the Final Safety Analysis Report (FSAR) or as evaluated in the Nuclear Regulatory Commission staffs Safety Evaluation Report (SER) (e.g., deletion of evaporators and installation of demineralizers); (2) Changes in the design of radwaste treatment systems that could significantly increase quantities of effluents released from those previously considered in the FSAR and SER;(3) Changes in system design which may invalidate the accident analysis as described in the SER (e.g., changes in tank capacity that would alter the curies released); or 9-46 VER 29 VEGP ODCM (4) Changes in system design that could potentially result in a significant increase in occupational exposure of operating personnel (e.g., use of temporary equipment without adequate shielding provisions). MEMBER(S) OF THE PUBLIC!A MEMBER OF THE PUBLIC means any individual except when that individual is receiving an occupational dose 2.This category may include persons who use portions of the site for recreational, occupational, or other purposes not associated with the plant.MINIMUM DETECTABLE CONCENTRATION The MINIMUM DETECTABLE CONCENTRATION (MDC) is defined, for purposes of the controls in this ODCM, as the smallest concentration of radioactive material in a sample that will yield a net count above system background and that will be detected with 95-percent probability, with only 5-percent probability of falsely concluding that a blank observation represents a "real" signal.For a particular measurement system, which may include radiochemical separation, the MDC for a given radionuclide is determined as follows (Reference 18): where: MDC = the a priori MINIMUM DETECTABLE CONCENTRATION (gCi per unit mass or volume).2.71 + 3.29 Rb t +MDC= ts E V -2.22 x 10 6 Y .e- At Rb = the background counting rate, or the counting rate of a blank sample, as appropriate (counts per minute).ts = the length of the sample counting period (minutes). tb = the length of the background counting period (minutes). E = the counting efficiency (counts per disintegration) V = the sample size (units of mass or volume).2.22 x 106 = the number of disintegrations per minute per ýtCi.Y = the fractional radiochemical yield, when applicable. The italicized terms in this definition, which are not otherwise used in this ODCM, shall have the definitions assigned to them by 10 CFR 20.1003.2 Except as delineated in other parts of 10 CFR chapter I.9-47 VER 29 VEGP ODCM X = the radioactive decay constant for the given radionuclide (h-').Values of X used in effluent calculations should be based on decay data from a recognized and current source, such as Reference 20.At = for effluent samples, the elapsed time between the midpoint of sample collection and the time of counting (h); for environmental samples, the elapsed time between the end of sample collection and the time of counting (h).Typical values of E, V, Y, and At should be used in the calculation. It should be recognized that the MDC is defined as an a priori (before the fact) limit representing the capability of a measurement system, and not as an a posteriori (after the fact)limit for a particular measurement. PRINCIPAL GAMMA EMITTERS The PRINCIPAL GAMMA EMITTERS for which the MINIMUM DETECTABLE CONCENTRATION (MDC) limit applies include exclusively the following radionuclides:
- For liquid radioactive effluents:
Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, and Ce-141. Ce-144 shall also be measured, but with an MDC of 5 x 10.-6 LtCi/mL.* For gaseous radioactive effluents: In noble gas releases, Kr-87, Kr-88, Xe-133, Xe-133m, Xe-135, Xe-138; and in particulate releases, Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141, and Ce-144.* For environmental media: The gamma emitters specifically listed in Table 4-3.These lists do not mean that only these nuclides are to be considered. Other gamma peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Radioactive Effluent Release Report, the Annual Radiological Environmental Operating Report, or other applicable report(s). SITE BOUNDARY For the purpose of effluent controls defined in the ODCM, the SITE BOUNDARY shall be as shown in Figure 4-1.SOURCE CHECK A SOURCE CHECK shall be the qualitative assessment of channel response when the channel sensor is exposed to a source of increased radioactivity. 9-48 VER 29 VEGP ODCM UNRESTRICTED AREA The UNRESTRICTED AREA shall be any area access to which is neither limited nor controlled by the licensee, or any area within the SITE BOUNDARY used for residential quarters or for industrial, commercial, institutional, and/or recreational purposes.VENTILATION EXHAUST TREATMENT SYSTEM The VENTILATION EXHAUST TREATMENT SYSTEM is any system designed and installed to reduce gaseous radioiodine or radioactive material in particulate form in effluents, by passing ventilation or vent exhaust gases through charcoal adsorbers and/or HEPA filters, for the purpose of removing iodines or particulates from the gaseous exhaust stream prior to the release to the environment. (Such a system is not considered to have any effect on any noble gas effluents). Engineered Safety Feature (ESF) atmospheric cleanup systems are not considered to be VENTILATION EXHAUST TREATMENT SYSTEM components. 9-49 VER 29 VEGP ODCM 10.2 TERMS DEFINED IN THE TECHNICAL SPECIFICATIONS The following terms are defined in the Technical Specifications, Section 1.0. Because they are used throughout the Limits of Operation sections of the ODCM, they are presented here for convenience. In the event of discrepancies between the definitions below and those in the Technical Specifications, the Technical Specification definitions shall take precedence. CHANNEL CALIBRATION A CHANNEL CALIBRATION shall be the adjustment, as necessary, of the channel, such that it responds within the required range and accuracy to known values of input. The CHANNEL CALIBRATION shall encompass the entire channel including the required sensor, alarm, interlock, and/or trip functions and may be performed by any series of sequential, overlapping, or total channel steps, so that the entire channel is calibrated. CHANNEL CHECK A CHANNEL CHECK shall be the qualitative assessment of channel behavior during operation by observation. This determination shall include, where possible, comparison of the channel indication and/or status with other indications and/or status derived from independent instrument channels measuring the same parameter. CHANNEL OPERATIONAL TEST (COT)A CHANNEL OPERATIONAL TEST shall be the injection of a simulated signal into the channel as close to the sensor as practicable to verify operability of required alarm, interlock, and/or trip functions. The CHANNEL OPERATIONAL TEST shall include adjustments, as necessary, of the required alarm, interlock, and/or trip setpoints, so that the setpoints are within the required range and accuracy.DOSE EQUIVALENT 1-131 DOSE EQUIVALENT 1-131 shall be that concentration of 1-131 (ýtCi/g) which alone would produce the same thyroid dose as the quantity and isotopic mixture of 1-131, 1-132, 1-133, 1-134, and 1-135 actually present. The thyroid dose conversion factors used for this calculation shall be those listed in EPA Federal Guidance Report No. 11, "Limiting Values of Radionuclide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submersion, and Ingestion," EPA-520/1-88-020, September 1988.MODE (or OPERATIONAL MODE)An OPERATIONAL MODE shall correspond to any one inclusive combination of core reactivity condition, power level, average reactor coolant temperature, and reactor vessel head closure bolt tensioning specified in Section 1.0 of the Technical Specifications with fuel in the reactor vessel.9-50 VER 29 VEGP ODCM OPERABLE (or OPERABILITY) OPERABILITY exists when a system, subsystem, train, component or device is capable of performing its specified function(s), and when all necessary attendant instrumentation, controls, electrical power, cooling or seal water, lubrication or other auxiliary equipment that are required for the system, subsystem, train, component or device to perform its function(s) are also capable of performing their related support function(s). RATED THERMAL POWER RATED THERMAL POWER shall be a total reactor core heat transfer rate to the reactor coolant of 3565 MWt.THERMAL POWER THERMAL POWER shall be the total reactor core heat transfer rate to the reactor coolant.9-51 VER 29}}