ENS 53844: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
(One intermediate revision by the same user not shown)
Line 12: Line 12:
| emergency class =  Non Emergency  
| emergency class =  Non Emergency  
| notification date = 01/24/2019 11:14
| notification date = 01/24/2019 11:14
| retracted = Yes
| notification by = Lawrence Gray
| notification by = Lawrence Gray
| NRC officer = Donald Norwood
| NRC officer = Donald Norwood
| event date = 01/24/2019 00:00 EST
| event date = 01/24/2019 00:00 EST
| last update date = 01/24/2019
| last update date = 02/18/2019
| title = Failure to Close and Lock Nuclear Gauge Shutter
| title = En Revision Imported Date  2/19/2019
| event text = The following was received via e-mail:
| event text = EN Revision Text: FAILURE TO CLOSE AND LOCK NUCLEAR GAUGE SHUTTER
The following was received via e-mail:
Between 2200 EST on January 23, 2019 and 0000 EST on January 24, 2019 a Ronan RLL1 [Density Scale Source] was unbolted from the frame on which it was mounted and placed on the floor. (Source was a Cs-137 0.54 milliCurie decayed to 0.45 milliCurie, Serial #212785A)  
Between 2200 EST on January 23, 2019 and 0000 EST on January 24, 2019 a Ronan RLL1 [Density Scale Source] was unbolted from the frame on which it was mounted and placed on the floor. (Source was a Cs-137 0.54 milliCurie decayed to 0.45 milliCurie, Serial #212785A)  
No permit was pulled to remove the scale source, and the shutter wasn't closed and locked out.  
No permit was pulled to remove the scale source, and the shutter wasn't closed and locked out.  
Line 27: Line 29:
The RSO then authorized a permit.  
The RSO then authorized a permit.  
Once the source was secured, and permit posted, the RSO did a full investigation.  
Once the source was secured, and permit posted, the RSO did a full investigation.  
Basic cause - The maintenance employee that unbolted the source entered the area from a direction that could only be accessed during a maintenance down. There was a radiation label on the scale itself, but no sign from his access point."
Basic cause - The maintenance employee that unbolted the source entered the area from a direction that could only be accessed during a maintenance down. There was a radiation label on the scale itself, but no sign from his access point.
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2019/20190201en.html#en53844
* * * RETRACTION ON 2/18/19 AT 1311 EST FROM LAWRENCE GRAY TO THOMAS KENDZIA * * *
Based on the findings of an NRC inspector, this event was determined to not be reportable since the shutter was fully functional and no exposure to personal occurred.
Notified R3DO (Duncan), NMSS Events Notification Group by email.
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2019/20190219en.html#en53844
}}
}}


{{ENS-Nav}}
{{ENS-Nav}}

Latest revision as of 07:30, 19 February 2019

ENS 53844 +/- *RETRACTED*
Where
Tilden Mining Company L.C.
Ishpeming, Michigan (NRC Region 3)
License number: 21-26748-01
Organization: Tilden Mining Company L.C.
Reporting
10 CFR 30.50(b)(2), Licensed Material Protection Equipment Failure
Time - Person (Reporting Time:+6.23 h0.26 days <br />0.0371 weeks <br />0.00853 months <br />)
Opened: Lawrence Gray
11:14 Jan 24, 2019
NRC Officer: Donald Norwood
Last Updated: Feb 18, 2019
53844 - NRC Website