- 05000416/LER-1982-082, Forwards LER 82-082/03L-0 +
- 05000321/LER-1982-082, Forwards LER 82-082/03L-0 +
- 05000331/LER-1982-082, Forwards LER 82-082/03L-0 +
- 05000373/LER-1982-082, Forwards LER 82-082/03L-0 +
- 05000324/LER-1982-082, Forwards LER 82-082/03L-0 +
- 05000325/LER-1982-082, Forwards LER 82-082/03L-0 +
- 05000327/LER-1982-082, Forwards LER 82-082/03L-0 +
- 05000321/LER-1978-082, Forwards LER 78-082/03L-0 +
- 05000369/LER-1982-082, Forwards LER 82-082/03L-0 +
- 05000339/LER-1982-082, Forwards LER 82-082/03L-0 +
- 05000338/LER-1982-082, Forwards LER 82-082/01T-0 +
- 05000272/LER-1982-082, Forwards LER 82-082/03L-0.Detailed Event Analysis Encl +
- 05000366/LER-1982-082, Forwards LER 82-082/03L-0 +
- 05000387/LER-1983-082, Requests Clerical Correction Be Made to Transmittal Ltr for LER 83-082/01T-0.Correct Ltr Number Is PLA-1741 +
- 05000333/LER-1978-082, Forwards LER 78-082/03L-0 +
- 05000295/LER-1978-082, Forwards LER 78-082/03L-0 +
- 05000354/LER-1986-082, :on 861028,HPCI Sys Declared Inoperable After Discovery That Flow Controller Proportional Gain Adjusted Earlier W/O Retest of HPCI Sys.Caused by Personnel Error. Hpic & RCIC Returned to Operable Status +
- 05000440/LER-1986-082, :on 861112,both Diesel Generator Bldg Ventilation Supply Sys Fans for Div 1 Diesel Generator auto-started Unexpectedly.Caused by Control Tachometer Problem.Engineering Design Change Initiated +
- 05000295/LER-1978-082-03, /03L-0:on 780802,during Normal Operation,Daily Surveillance for Radiation Monitor in Control Room Intake from Turbine Bldg Omitted.Monitor Operable Prior to & After Missed Surveillance +
- 05000528/LER-1985-082, :on 850516,failure of Train a Emergency Diesel Generator to Load During Surveillance Testing Not Reported. Caused by Personnel Error.Personnel Responsible Will Be Briefed on Reporting Requirements +
- 05000341/LER-1985-082, :on 851204,determined That Embedded Support Plates in Reactor Auxiliary Bldg Potentially Overloaded. Embedded Plates Acceptable,Based on Sargent & Lundy Analyses.Design Changes Do Not Affect Plates +
- 05000454/LER-1985-082, :on 850811,waste Gas Sys Samples Not Obtained & Analyzed.Caused by Personnel Error.New Communication & Limiting Condition for Operation Action Statement Handling Mechanisms Implemented +
- 05000482/LER-1985-082, :on 851202,casing Failure on Potential Transformer Caused Loss of Offsite Power to ESF Transformer XNB01.Caused by Failure of Metering & Relay Potential Transformer Monitoring.Sys Restored +
- 05000374/LER-1984-082-01, :on 841207,rectangular Hold Discovered in Top of Entrance Way to Condenser Water Box,Compromising Positive Control Over High Radiation Entry.Caused by Design Oversight.Hole Blocked +
- 05000373/LER-1984-082, :on 841124,reactor Water Cleanup Sys Isolated on High Differential Flow.Caused by Reactor Startup Due to Water Temp,Pressure & Density Differences Between Startup Operations & Instrument Calibr +
- 05000397/LER-1984-082, :on 840802,23 & 1004,during Shutdown,Rcic Isolated on Spurious High Steam Flow Indication.Caused by Mispositioned Line Break Detection Setpoint on RCIC Differential Pressure Switches +
- 05000260/LER-1983-082-03, /03L-0:on 831223,during Normal Operation, Recirculation Pump 2A Tripped Due to Actuation of Relay 2A-K21A Neutral Overvoltage.Caused by Gouged Insulation on Phase C Conductor in Cable 2PP1005 +
- 05000338/LER-1983-082-03, /03L-0:on 831121,outer Seal on Containment Personnel Hatch Failed to Pass Periodic Test Following Entry.Caused by Accumulation of Dirt on Seal.Seal Cleaned & Relubricated +
- 05000348/LER-1983-082-03, /03L-0:on 831202,specific Gravity on Auxiliary Bldg Train a Battery Cell 40 Found Low.Cause Undetermined. Affected Cell Recharged +
- 05000324/LER-1983-082-03, /03L-0:on 830902,suppression Pool Level Exceeded Specs W/Value of -26.25 Inches.Caused by Failure of Operator to Adequately Monitor Level While Instrumentation Out of Svc Due to Plant Mod.Level Returned to Specs +
- 05000369/LER-1983-082-03, /03L-0:on 830911,pressurizer Heater Group 1B Declared Inoperable When Operation Did Not Aid in RCS Pressure Control.Caused by Blown 500 Amp Line Fuse in Vacuum Contractor Cabinet.Fuse Replaced +
- 05000370/LER-1983-082-03, /03L-0:on 831126,surveillance Test on Ice Condenser Intermediate Deck Door Not Performed.Door Declared Inoperable.Caused by Operator Error.Test Performed Satisfactorily on 831128 +
- 05000416/LER-1983-082-01, During 18-month Testing, Starting Air Valve for Right Cylinder 8 & Left Bank Cylinder 1 Failed.Caused by Contamination of Atmospheric Vent Lines & Malfunctions of Air Distributor +
- 05000373/LER-1983-082-03, /03L-0:on 830711,before Performance of LIS-PR-04, Temporary Particulate & Iodine Monitoring Equipment Not Connected within Tech Spec Time Limit.Caused by Personnel Error.Precaution Added to Procedure +
- 05000237/LER-1983-082-03, /03L-0:on 831225,while Performing Weekly & Daily Turbine Checks During Normal Operation,Control Valve 4 Failed to Give half-scram When Tested.Probably Caused by Failed Test Switch CVTS-4.Recorder Installed +
- 05000362/LER-1983-082-03, /03L-0:on 831005,qualified Safety Parameter Display Sys Train B Taken Out of Svc Due to Smoky Odor Eminating from Cabinet.Caused by Failed Circuit Board. Circuit Board Replaced +
- 05000366/LER-1983-082-03, /03L-0:on 830922,operations Personnel Determined RCIC Percent Demand Indication Off.On 830925,RCIC Failed to Reach Rated Flow & Pressure.Caused by Setpoint Drift.High Current Limiter Adjusted +
- 05000316/LER-1983-082-03, /03L-0:on 830826,during startup,body-to-bonnet Leak Reported on East Containment Spray HX Inlet Valve 2-CTS-121E.Cause Undetermined.East Train Removed from Svc to Repair Leak.Bonnet Gasket Replaced +
- 05000315/LER-1983-082-03, /03L-0:on 830815,train a Lower Containment Airborne Monitor ERS-1300 Declared Inoperable.Caused by Piece of Metal on Circuit Board Connector.Circuit Boards Cleaned +
- 05000321/LER-1983-082-03, /03L-0:on 830729,during Control Room Panel Walkdown,Hpci Pump Room Cooler Indicator Light on Control Room Panel Not Lit,Indicating Cooler Inoperable.Caused by Electrical Power Circuit Being in Off Position +
- 05000361/LER-1983-082-03, /03L-0:on 830718,supervisory Trouble Alarm Sounded Involving Fire Detection Panel 2/3L-236.Caused by Inadvertent Circuit Interruption by Contract Electrician. Circuit Repaired +
- 05000395/LER-1983-082-03, /03L-0:on 830718,diesel Generator B Tripped After Running for 12 Minutes During Surveillance Test.Caused by Spurious Alarm on High Crankcase Pressure. Switch Calibr Verified & Diesel Inspected +
- 05000333/LER-1978-082-03, /03L-0:on 780920,during Refueling Shutdown, Pressure Suppression Pool Torus Level Increased to 0.8 Inches Above Tech Spec Limit.Caused by Leaking Past Seat of Safety Relief Valve +
- 05000369/LER-1982-082-03, /03L-0:on 821231,while in Mode 5,three Instrument Loops Found Out of Tolerance.Caused by Differential Pressure Transmitter Drift.Transmitters Recalibr +
- 05000338/LER-1982-082-01, /01T-0:on 821206,both Trains of Automatic Safety Injection Blocked for 22 H & 30 Minutes Following Inadvertent Safety Injection.Caused by Emergency Procedure Which Misled Operators.Procedure Revised +
- 05000339/LER-1982-082-03, /03L-0:on 821213,fire Door S71-18 Between 2H Emergency Diesel Generator Room & Turbine Bldg Failed to Latch & Lock.Caused by Latch Sticking.Latch Adjusted & Lubricated.Design Mods Pursued +
- 05000272/LER-1982-082-03, /03L-0:on 821025,thermal Detectors for Iodine Removal Sys & Pressure Relief Sys Discovered Missing from Fire Detection Instrumentation Surveillance Procedures. Caused by Oversight During Procedure Inception +
- 05000316/LER-1982-082-03, LER-082/03L-0:on 821007,during Test on Fire Protection Carbon Dioxide Sys,Weld Leak Developed on One Leg of 4-inch Tee Fitting.Caused by Defective Weld.Weld Repaired & Inspected +
- 05000366/LER-1982-082-03, /03L-0:on 820928,RCIC Turbine Exhaust Vent Pressure Switch 2 Actuated at 10.45 Psig.Caused by Component Failure of Switch Due to Setpoint Drift.Switch Recalibr +
- 05000321/LER-1982-082-03, /03L-0:on 820911,LPCI a Inverter Tripped.Unit Placed in 7-day Limiting Condition for Operation.Caused by Failure of Output Filter Capacitor.Six Fuses & 2 Output Filter Capacitors Replaced.Inverter Placed in Svc on 820913 +