J!. Southern Nuclear November 21, 2024 Docket No.:

52-025 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Regulatory Affairs Southern Nuclear Operating Company Vogtle Electric Generating Plant - Unit 3 Core Operating Limits Report, Cycle 2, Version 1 Ladies and Gentlemen:

3535 Colonnade Parkway Birmingham, AL 35243 205 992 5000 NL-24-0408 10 CFR 52.97(c)

In accordance with Technical Specification (TS) 5.6.3.d for Vogtle Electric Generating Plant (VEGP) Units 3 and 4, Southern Nuclear Operating Company (SNC) submits the VEGP Core Operating Limits Report (COLR) for Unit 3, Cycle 2, Version 1. provides the Non-Proprietary version of the COLR. provides the Proprietary version of the COLR. The enclosure contains Proprietary information; therefore, SNC requests that this enclosure be withheld under the provisions of 10 CFR 2.390. is CAW-24-047, Application for Withholding Proprietary Information from Public Disclosure and Affidavit. Enclosure 2 contains information proprietary to Westinghouse Electric Company LLC ("Westinghouse"); it is supported by an Affidavit signed by Westinghouse, the owner of information. The Affidavit sets forth the basis on which the information may be withheld from public disclosure by the Nuclear Regulatory Commission ("Commission") and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.390 of the Commission's regulations.

Accordingly, it is respectfully requested that the information that is proprietary to Westinghouse be withheld from public disclosure in accordance with 10 CFR Section 2.390 of the Commission's regulations.

Correspondence with respect to the copyright or proprietary aspects of the items listed above or the supporting Westinghouse Affidavit should reference CAW-24-047 and should be addressed to Anthony J. Schoedel, Manager, eVinci Licensing &

Configuration Management, Westinghouse Electric Company, 1000 Westinghouse Drive, Cranberry Township, Pennsylvania 16066.

U. S. Nuclear Regulatory Commission NL-24-0408 Page 2 This letter contains no regulatory commitments. This letter has been reviewed and determined not to contain security-related information.

If you have any questions, please contact Ryan Joyce at 205.992.6468.

Respectfully submitted, Jamie M. Coleman Regulatory Affairs Director Southern Nuclear Operating Company

Enclosures:

1) Vogtle Electric Generating Plant (VEGP) Unit 3 - Core Operating Limits Report (COLR), Cycle 2, Version 1 (Non-Proprietary)
2) Vogtle Electric Generating Plant (VEGP) Unit 3 - Core Operating Limits Report (COLR), Cycle 2, Version 1 (Proprietary) (Withheld Information)
3) Vogtle Electric Generating Plant (VEGP) Unit 3 - Westinghouse Application for Withholding Proprietary Information from Public Disclosure CAW-24-047 and accompanying Affidavit cc:

Regional Administrator, Region 11 NRR Project Manager-VEGP 3&4 Senior Resident Inspector-VEGP 3&4 Document Services RTYPE: VND.LI.LO0

Southern Nuclear Operating Company NL-24-0408 Vogtle Electric Generating Plant (VEGP) Unit 3 Core Operating Limits Report (COLR), Cycle 2, Version 1 (Non-Proprietary)

(This Enclosure consists of 35 pages, including this cover page)

Page A-1 of 34 VOGTLE ELECTRIC GENERATING PLANT UNIT 3 CYCLE 2 CORE OPERATING LIMITS REPORT NON-PROPRIETARY VERSION

Westinghouse Non-Proprietary Class 3 VOGTLE ELECTRIC GENERATING PLANT (VEGP)

UNIT 3 CYCLE 2 CORE OPERATING LIMITS REPORT (COLR)

Version 1 September 2024 Page A-2 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 1.0 CORE OPERATING LIMITS REPORT This Core Operating Limits Report (COLR) for the Vogtle Electric Generating Plant, Unit 3, Cycle 2 has been prepared in accordance with the requirements of Technical Specification 5.6.3.

The Technical Specification Safety Limits (SLs) and Limiting Conditions for Operation (LCOs) affected by this report are listed below:

SL 2.1.1 Reactor Core SLs LCO 3.1.1 SHUTDOWN MARGIN (SOM)

LCO 3.1.3 Moderator Temperature Coefficient (MTC)

LCO 3.1.5 Shutdown Bank Insertion Limits LCO 3.1.6 Control Bank Insertion Limits LCO 3.2.1 Heat Flux Hot Channel Factor (Fa(Z)) (Constant Axial Offset Control (CAOC) W(Z) Methodology)

LCO 3.2.2 Nuclear Enthalpy Rise Hot Channel Factor (F~H)

LCO 3.2.3 AXIAL FLUX DIFFERENCE (AFD) (Constant Axial Offset Control (CAOC) Methodology)

LCO 3.2.5 On-Line Power Distribution Monitoring System (OPDMS)-Monitored Parameters LCO 3.4.1 RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits LCO 3.9.1 Boron Concentration Page A-3 of 34

2.0 2.1 Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 OPERATING LIMITS Reactor Core SLs (SL 2.1.1)

The Reactor Core SLs for MODES 1 and 2 are:

2.2 2.1.1 The combination of THERMAL POWER, RCS highest loop cold leg temperature, and pressurizer pressure shall not exceed the limits specified in Table 2.1.1 and Figure 2.1.1.

SHUTDOWN MARGIN (SOM)

(LCO 3.1.1)

The SOM limit for MODE 2 with kett < 1.0 is:

2.2.1 The SOM shall be greater than or equal to 1.6%.b.k/k.

The SOM limit for MODES 3, 4, and 5 is:

2.2.2 The SOM shall be greater than or equal to 1.6%.b.k/k.

Page A-4 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.1.1 Reactor Core Safety Limits a,c Page A-5 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Figure 2.1.1 Reactor Core Safety Limits a,c Page A-6 of 34

2.3 Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Moderator Temperature Coefficient (MTC)

(LCO 3.1.3)

The BOL/ARO MTC upper limit (SR 3.1.3.1) for MODE 1 and MODE 2 with kett ~ 1.0 is:

2.3.1 The MTC shall be more negative than or equal to the power-dependent upper limit specified in Figure 2.3.1.

The EOL/ARO MTC lower limit (SR 3.1.3.2) for MODES 1, 2, and 3 is:

2.3.2 The MTC shall be less negative than or equal to

[

]a,c The ARO/HFP MTC surveillance limits (SR 3.1.3.2) for EOL are:

2.3.3 At 300 ppm, the MTC shall be less negative than or equal to

[

]a,c 2.3.4 At 60 ppm, the MTC shall be less negative than or equal to

[

]a,c SR 3.1.3.2 does not need to be performed provided both the of following conditions are met:

2.3.5 The measured-to-predicted differences for the parameters listed in Table 2.3.5 are within their specified criteria.

2.3.6 The value of the revised predicted MTC, calculated in accordance with Table 2.3.6, is less negative than the ARO/HFP MTC surveillance limit at 300 ppm.

Note: ARO stands for All Rods Out BOL stands for Beginning of (Cycle) Life EOL stands for End of (Cycle) Life HFP stands for Hot Full (Thermal) Power Page A-7 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Figure 2.3.1 BOL/ARO MTC Upper Limit a,c Page A-8 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERA TING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.3.5 Benchmark Criteria for Application of the EOL MTC Measurement Conditional Exemption Parameter Criteria Time/ Activity Power Ascension Assembly

+/- 0.10 or Testing Power 10%

Routinely at RTP

[

la,c lncore Quadrant

+/-4%

Power Ascension Tilt (Low Power)

Testing Power Ascension lncore Quadrant Testing Tilt (RTP)

+/-2%

Routinely at RTP

[

]a,c Low Power Physics Testing Power Ascension Core Reactivity

+/- 1000 pcm Testing Routine Surveillance Requirement Low Power Physics BOL HZP ITC

+/- 2.0 pcm/°F Testing (or verification)

Individual

+/- 75 pcm Low Power Physics Testing (or Bank Worth or 10%

verification)

Total Low Power Physics Bank Worth

+/- 5.6%

Testing (or verification)

Note: EFPD stands for effective full power days EQXE stands for equilibrium xenon HZP stands for Hot Zero (Thermal) Power Minimum Documentation Frequency Twice - At an intermediate power (40-75% RTP) plateau and at a full power (> 90% RTP) plateau Every 31 EFPDs after reaching RTP Once - At a low power(~ 30% RTP) plateau Once - At the RTP power ascension test plateau Every 31 EFPDs after reaching RTP Once - After fuel load and prior to MODE 1 (SR 3.1.2.1)

Once - In MODE 1 upon reaching RTP and EQXE conditions

("Hot Full Power Boron Endpoint")

After 60 EFPD, every 31 EFPD thereafter (continuation of SR 3.1.2.1)

Once - After fuel load and prior to MODE1 (needed to support SR 3.1.3.1)

Once - After fuel load and prior to MODE1 Once - After fuel load and prior to MODE1 ITC stands for Isothermal Temperature Coefficient OPDMS stands for Online Power Distribution Monitoring System RTP stands for rated thermal power SR stands for surveillance requirement Page A-9 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.3.6 Algorithm for Calculation of the Revised Predicted MTC at 300 ppm a,c Page A-1 O of 34

2.4 Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Shutdown Bank Insertion Limits (LCO 3.1.5)

The shutdown bank insertion limits in MODES 1 and 2 are:

2.5 2.4.1 All shutdown banks shall be positioned greater than or equal to [

withdrawn (swd).

Control Bank Insertion Limits (LCO 3.1.6)

]a,c steps The control bank rod insertion limits (Rlls), sequence limits, and overlap limits in MODE 1 and MODE 2 with kett ~ 1.0 are:

2.5.1 M-Bank Limits 2.5.1.a With the OPDMS functional, the M-Banks shall be positioned greater than or equal to the power-dependent limit specified in Figure 2.5.1.a.

2.5.1.b With the OPDMS not functional, the M-Banks shall be positioned greater than or equal to the power-dependent limit specified in Figure 2.5.1.b. M-Bank Insertion Limits are provided for two CAOC Operating Spaces (COSs). The M-Bank Insertion Limits for each COS shall be used in conjunction with the associated Axial Flux Difference Limits for the COS.

(Note: The same RI Ls apply regardless of OPDMS functionality or COS for this cycle.)

2.5.1.c The M-Banks shall be considered fully withdrawn from the core when positioned greater than or equal to [

]a,c swd.

Note: ARO positions of [

]a,c through [

]a,c swd may be utilized during rod repositioning without affecting the core safety analysis.

2.5.1.d When the ARO position is [

]a,c swd, the M-Banks shall be operated in sequence as specified in Table 2.5.1.d, and each M-Bank not fully withdrawn from the core shall be operated within the overlap limits specified in Table 2.5.1.d.

2.5.1.e When the ARO position is [

]a,c swd, the M-Banks shall be operated in sequence as specified in Table 2.5.1.e, and each M-Bank not fully withdrawn from the core shall be operated within the overlap limits specified in Table 2.5.1.e.

Page A-11 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 2.5.1.f When the ARO position is [

]a,c swd, the M-Banks shall be operated in sequence as specified in Table 2.5.1.f, and each M-Bank not fully withdrawn from the core shall be operated within the overlap limits specified in Table 2.5.1.f.

2.5.1.g When the ARO position is [

]a,c swd, the M-Banks shall be operated in sequence as specified in Table 2.5.1.g, and each M-Bank not fully withdrawn from the core shall be operated within the overlap limits specified in Table 2.5.1.g.

2.5.2 Bank AO Limits 2.5.2.a Bank AO shall be positioned greater than or equal to the power-dependent limit specified in Figure 2.5.2.a.

2.5.2.b Bank AO shall be considered fully withdrawn from the core when positioned greater than or equal to [

]a,c swd.

Page A-12 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Figure 2.5.1.a M-Bank Rod Insertion Limits (OPDMS Functional) a,c Page A-13 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Figure 2.5.1.b M-Bank Rod Insertion Limits for CAOC Operating Spaces 1 and 2 (OPDMS Not Functional) a,c Page A-14 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.5.1.d M-Bank Sequences and Overlap Settings

[.

Ja,csteps ARO Page A-15 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.5.1.e M-Bank Sequences and Overlap Settings

[

la.c steps ARO ac Table 2.5.1.f M-Bank Sequences and Overlap Settings

[

Ja,c steps ARO a.c Page A-16 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.5.1.g M-Bank Sequences and Overlap Settings

[

Ja,c steps ARO a,c Page A-17 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Figure 2.5.2.a Bank AO Rod Insertion Limits a,c Page A-18 of 34

2.6 Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Heat Flux Hot Channel Factor (Fo(Z)) (Constant Axial Offset Control (CAOC) W(Z)

Methodology)

(LCO 3.2.1)

The Fa(Z) limits in MODE 1 with THERMAL POWER ~ 25% RTP and with the OPDMS not functional with respect to LCO 3.2.5 a, b, and care:

2.6.1 Fg(Z) ::; c:a for P > 0.5 Fg(Z)::; c;~ for P::; 0.5 where: p THERMAL POWER

= RATED THERMAL POWER CFQ = 2.60 where: F~ (Z) represents the measured value of Fa(Z), and is obtained from power distribution measurement results.

F~u (Z) is a factor that accounts for fuel manufacturing tolerances (net effect being a factor of 1.03) and power distribution measurement uncertainty, the latter being dependent on the fraction of inoperable incore detectors and the detector measurement variability at the conditions of the power distribution measurement. Therefore, F~u (Z) is defined at the time of measurement using approved methods.

2.6.3 F~ (Z) ::; c:a for P > 0.5 F~ (Z) ::; c;~ for P ::; 0.5 COLR where: F~ (Z) = Fg(Z) * [W(Z~

  • Aa(Z)
  • Ri for P > 0.5 The calculation of Faw(Z) in the equations above is dependent on the applicable CAOC operating space, as detailed in items 2.6.3.a and 2.6.3.c below. Margin to the F0W(Z) limit may be improved by implementing a more restrictive COS in accordance with TS LCO 3.2.1 Required Action B.1.1. If this margin improvement is not sufficient to restore Faw(Z) to within its limits, the THERMAL POWER limits discussed in Item 2.6.3.d below may be required in accordance with TS LCO 3.2.1 Required Action B.2.1.

Page A-19 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 2.6.3.a [W(Z)]C0 LR is a cycle-dependent function that accounts for power distribution transients encountered during normal operation. The [W(Z)]C0 LR function is dependent on CAOC operating space, core elevation and core burnup.

[W(Z)]coLR values are specified in Tables 2.6.3.a.1 and 2.6.3.a.2 for COS 1 and COS2, respectively.

2.6.3.b The Ao(Z) factor adjusts the surveillance to the Target AO conditions. Ao(Z) can be assumed to be equal to 1.0 if the conditions discussed below are met, or may be determined for specific surveillance conditions using approved methods. Specifically, Ao(Z) can be assumed to be equal to 1.0 if the surveillance is performed at core conditions consistent with updating the measured Target AO and Control Bank M1 is not inserted below [

]a,c steps withdrawn. Alternatively, Ao(Z) can be assumed to be equal 1.0 if a surveillance specific W(Z) function is being used that is consistent with the core conditions of the surveillance.

2.6.3.c The Rj penalty factors account for the potential decrease in transient FQ margin between surveillances. The Rj factors for COS1 and COS2 are provided in Tables 2.6.3.c.1 and 2.6.3.c.2, respectively.

2.6.3.d Table 2.6.3.d provides the required limits on thermal power for each COS in the event that additional margin is required.

Page A-20 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.6.3.a.1

[W(Z)f0 LR Function for COS1 Core

[W(Z)f0 LR Factors by Core Burnup Elevation (in) 150 6000 12000 18000 0.00 1.315 1.347 1.420 1.468 2.01 1.327 1.354 1.421 1.469 4.02 1.323 1.337 1.412 1.460 6.04 1.318 1.333 1.406 1.451 8.05 1.320 1.329 1.387 1.418 10.06 1.313 1.322 1.374 1.399 12.07 1.305 1.312 1.358 1.385 14.08 1.297 1.304 1.347 1.373 16.10 1.282 1.288 1.328 1.353 18.11 1.272 1.278 1.316 1.339 20.12 1.260 1.266 1.302 1.323 22.13 1.246 1.253 1.287 1.304 24.14 1.231 1.237 1.268 1.290 26.16 1.215 1.222 1.250 1.270 28.17 1.202 1.206 1.233 1.250 30.18 1.182 1.191 1.213 1.226 32.19 1.164 1.176 1.195 1.210 34.20 1.145 1.162 1.177 1.191 36.22 1.128 1.147 1.158 1.171 38.23 1.112 1.135 1.141 1.153 40.24 1.097 1.122 1.125 1.140 42.25 1.089 1.110 1.110 1.131 44.26 1.100 1.099 1.099 1.121 46.28 1.111 1.096 1.099 1.119 48.29 1.122 1.095 1.105 1.138 50.30 1.139 1.097 1.112 1.164 52.31 1.155 1.099 1.118 1.187 54.32 1.174 1.112 1.136 1.201 56.34 1.193 1.106 1.135 1.231 58.35 1.210 1.112 1.145 1.251 60.36 1.226 1.118 1.156 1.271 62.37 1.242 1.126 1.166 1.281 64.38 1.255 1.134 1.175 1.303 66.40 1.268 1.141 1.182 1.325 68.41 1.279 1.147 1.189 1.342 Page A-21 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.6.3.a.1

[W(Z)f0 LR Function for COS1 Core

[W(Z)f0 LR Factors by Core Burnup Elevation (in) 150 6000 12000 18000 70.42 1.289 1.153 1.195 1.359 72.43 1.296 1.158 1.199 1.375 74.44 1.302 1.161 1.211 1.375 76.46 1.311 1.165 1.223 1.397 78.47 1.320 1.171 1.235 1.405 80.48 1.326 1.174 1.246 1.414 82.49 1.333 1.179 1.256 1.420 84.50 1.337 1.181 1.265 1.419 86.52 1.340 1.182 1.277 1.429 88.53 1.341 1.182 1.284 1.427 90.54 1.339 1.181 1.286 1.420 92.55 1.338 1.181 1.289 1.415 94.56 1.335 1.182 1.282 1.377 96.58 1.332 1.183 1.290 1.397 98.59 1.328 1.184 1.288 1.389 100.60 1.323 1.183 1.285 1.379 102.61 1.313 1.181 1.277 1.368 104.62 1.303 1.179 1.270 1.359 106.64 1.290 1.179 1.258 1.347 108.65 1.276 1.178 1.248 1.335 110.66 1.259 1.175 1.233 1.319 112.67 1.246 1.172 1.233 1.302 114.68 1.234 1.171 1.235 1.289 116.70 1.211 1.174 1.226 1.259 118.71 1.196 1.175 1.223 1.242 120.72 1.180 1.175 1.217 1.241 122.73 1.178 1.173 1.210 1.239 124.74 1.176 1.172 1.203 1.240 126.76 1.173 1.171 1.195 1.230 128.77 1.172 1.166 1.189 1.224 130.78 1.172 1.160 1.180 1.222 132.79 1.171 1.158 1.178 1.215 134.80 1.180 1.166 1.178 1.212 136.82 1.190 1.177 1.180 1.211 138.83 1.195 1.186 1.192 1.214 140.84 1.212 1.203 1.209 1.227 142.85 1.231 1.220 1.226 1.243 144.86 1.251 1.239 1.246 1.263 Page A-22 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.6.3.a.1

[W(Z)]coLR Function for CO51 Core

[W(Z)]C0 LR Factors by Core Burnup Elevation (in) 150 6000 12000 18000 146.88 1.272 1.257 1.268 1.285 148.89 1.292 1.276 1.291 1.309 150.90 1.309 1.293 1.310 1.339 152.91 1.332 1.307 1.339 1.363 154.92 1.349 1.328 1.363 1.383 156.94 1.376 1.350 1.432 1.420 158.95 1.401 1.404 1.506 1.529 160.96 1.413 1.412 1.511 1.530 162.97 1.469 1.531 1.629 1.652 164.98 1.488 1.550 1.652 1.678 167.00 1.505 1.557 1.649 1.656 169.01 1.515 1.566 1.662 1.682 Notes:

The [W(Z)]C0 LR values are unit-less and the core burnup values are in units of MWD/MTU.

. [

The top and bottom 8% of the core (inclusive) are excluded from the F~(Z) evaluation because of the difficulty of making a precise measurement in these regions and because of the low probability that these regions would be more limiting than the safety analyses.

Page A-23 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.6.3.a.2

[W(Z)f0 LR Function for COS2 Core

[W(Z)f0 LR Factors by Core Burnup Elevation (in) 150 6000 12000 18000 0.00 1.300 1.328 1.401 1.448 2.01 1.312 1.336 1.401 1.449 4.02 1.309 1.319 1.392 1.440 6.04 1.304 1.315 1.386 1.432 8.05 1.305 1.312 1.367 1.400 10.06 1.299 1.306 1.355 1.380 12.07 1.291 1.296 1.340 1.367 14.08 1.282 1.289 1.331 1.356 16.10 1.268 1.273 1.312 1.336 18.11 1.258 1.264 1.301 1.322 20.12 1.246 1.252 1.287 1.306 22.13 1.233 1.239 1.272 1.288 24.14 1.218 1.223 1.253 1.274 26.16 1.203 1.209 1.236 1.255 28.17 1.190 1.193 1.219 1.236 30.18 1.169 1.178 1.200 1.213 32.19 1.152 1.164 1.182 1.197 34.20 1.134 1.149 1.164 1.179 36.22 1.118 1.135 1.145 1.158 38.23 1.101 1.123 1.129 1.141 40.24 1.087 1.111 1.113 1.125 42.25 1.079 1.099 1.099 1.112 44.26 1.090 1.089 1.088 1.107 46.28 1.101 1.085 1.088 1.108 48.29 1.112 1.085 1.096 1.128 50.30 1.129 1.088 1.102 1.154 52.31 1.145 1.090 1.109 1.178 54.32 1.165 1.104 1.127 1.192 56.34 1.184 1.097 1.126 1.223 58.35 1.201 1.103 1.137 1.243 60.36 1.218 1.110 1.147 1.262 62.37 1.233 1.118 1.158 1.273 64.38 1.247 1.126 1.167 1.295 66.40 1.260 1.133 1.175 1.317 68.41 1.272 1.140 1.182 1.335 70.42 1.281 1.146 1.189 1.353 72.43 1.290 1.151 1.194 1.370 74.44 1.300 1.155 1.205 1.369 Page A-24 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.6.3.a.2

[W(Z)f0 LR Function for COS2 Core

[W(Z)f0 LR Factors by Core Burnup Elevation (in) 150 6000 12000 18000 76.46 1.311 1.161 1.219 1.394 78.47 1.320 1.167 1.231 1.403 80.48 1.326 1.171 1.244 1.413 82.49 1.333 1.176 1.255 1.419 84.50 1.337 1.178 1.265 1.419 86.52 1.340 1.180 1.277 1.429 88.53 1.341 1.181 1.284 1.427 90.54 1.339 1.181 1.286 1.420 92.55 1.338 1.181 1.289 1.415 94.56 1.335 1.182 1.282 1.377 96.58 1.331 1.183 1.289 1.397 98.59 1.326 1.183 1.286 1.387 100.60 1.320 1.182 1.282 1.377 102.61 1.309 1.178 1.274 1.365 104.62 1.298 1.176 1.266 1.356 106.64 1.284 1.175 1.253 1.343 108.65 1.269 1.174 1.241 1.330 110.66 1.255 1.170 1.228 1.313 112.67 1.241 1.166 1.226 1.295 114.68 1.228 1.165 1.226 1.282 116.70 1.204 1.166 1.217 1.251 118.71 1.189 1.166 1.214 1.235 120.72 1.171 1.166 1.209 1.233 122.73 1.169 1.163 1.200 1.230 124.74 1.166 1.161 1.191 1.229 126.76 1.162 1.158 1.181 1.219 128.77 1.161 1.152 1.174 1.213 130.78 1.159 1.145 1.165 1.209 132.79 1.156 1.144 1.164 1.201 134.80 1.164 1.150 1.163 1.197 136.82 1.172 1.158 1.167 1.196 138.83 1.179 1.171 1.181 1.197 140.84 1.198 1.186 1.198 1.213 142.85 1.217 1.202 1.214 1.230 144.86 1.236 1.219 1.233 1.252 146.88 1.256 1.234 1.254 1.274 148.89 1.275 1.256 1.278 1.298 150.90 1.292 1.273 1.296 1.328 Page A-25 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.6.3.a.2

[W(Z)]coLR Function for COS2 Core

[W(Z)]coLR Factors by Core Burnup Elevation (in) 150 6000 12000 18000 152.91 1.315 1.286 1.327 1.351 154.92 1.334 1.304 1.352 1.371 156.94 1.360 1.350 1.412 1.400 158.95 1.369 1.404 1.487 1.529 160.96 1.380 1.412 1.493 1.530 162.97 1.424 1.531 1.608 1.652 164.98 1.441 1.550 1.633 1.678 167.00 1.456 1.557 1.629 1.656 169.01 1.465 1.566 1.641 1.682 Notes:

The [W(Z)]C0 LR values are unit-less and the core burnup values are in units of MWD/MTU.

. [

]a,c The top and bottom 8% of the core (inclusive) are excluded from the F~(Z) evaluation because of the difficulty of making a precise measurement in these regions and because of the low probability that these regions would be more limiting than the safety analyses.

Page A-26 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.6.3.c.1 Ri Margin Decrease Factors for COS1 Cycle Burnup Ri Cycle Burnup Ri Cycle Burnup Ri (MWD/MTU)

(MWD/MTU)

(MWD/MTU)

BU::; 1132.9 1.00 6440.7 1.02 16073.2 1.02 1329.5 1.01 6637.2 1.01 16466.4 1.02 1526.1 1.01 10372.3 1.01 16663.0 1.03 1722.7 1.02 10568.9 1.02 17056.1 1.03 2115.8 1.02 11355.2 1.02 17252.7 1.04 2312.4 1.03 11551.8 1.01 17645.9 1.04 2509.0 1.02 11748.4 1.01 17842.5 1.03 3098.7 1.02 11945.0 1.02 20594.6 1.03 3295.3 1.01 13321.1 1.02 20791.2 1.02 4474.8 1.01 13517.6 1.01 21184.4 1.02 4671.4 1.00 13910.8 1.01 21381.0 1.01 5064.6 1.00 14107.4 1.02 21774.1 1.01 5261.2 1.01 15286.9 1.02 BU~ 21970.7 1.00 5654.3 1.01 15483.5 1.01 5850.9 1.02 15876.6 1.01 Notes:

Values may be interpolated to the surveillance cycle burnup.

Page A-27 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.6.3.c.2 Ri Margin Decrease Factors for COS2 Cycle Burnup Ri Cycle Burnup Ri Cycle Burnup Ri (MWD/MTU)

(MWD/MTU)

(MWD/MTU)

BU::; 1132.9 1.00 10962.1 1.02 19611.7 1.04 1329.5 1.01 11158.6 1.01 19808.3 1.04 1526.1 1.01 11945.0 1.01 20004.9 1.03 1722.7 1.02 12141.6 1.02 20594.6 1.03 2115.8 1.02 13321.1 1.02 20791.2 1.02 2312.4 1.03 13517.6 1.01 21184.4 1.02 2509.0 1.02 13910.8 1.01 21381.0 1.01 3098.7 1.02 14107.4 1.02 21774.1 1.01 3295.3 1.01 15876.6 1.02 BU~ 21970.7 1.00 4474.8 1.01 16073.2 1.03 4671.4 1.00 17056.1 1.03 5457.7 1.00 17252.7 1.04 5654.3 1.01 17842.5 1.04 10372.3 1.01 18039.0 1.03 10568.9 1.02 19415.1 1.03 Notes:

Values may be interpolated to the surveillance cycle burnup.

Page A-28 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.6.3.d Required THERMAL POWER Limits CAOC Operating Space Required fQw(Z) Margin Required THERMAL Improvement (%)

POWER Limit (%RTP)

5.0
95 COS1

> 5.0

< 50

5.0
95 COS2

> 5.0

< 50 Page A-29 of 34

2.7 Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Nuclear Enthalpy Rise Hot Channel Factor (F~H)

(LCO 3.2.2)

The F~H limits in MODE 1 with THERMAL POWER ~ 25% RTP and with the OPDMS not functional with respect to LCO 3.2.5 a, b, and care:

2.7.1 F~H= F~~P * (1 + PFtiH * (1 - P))

where: p THERMAL POWER

= RATED THERMAL POWER PF tiH = 0.3 2.8 AXIAL FLUX DIFFERENCE (AFD) (Constant Axial Offset Control (CAOC)

Methodology)

(LCO 3.2.3)

The AFD limits in MODE 1 with THERMAL POWER > 15% RTP and with the OPDMS not functional with respect to LCO 3.2.5 a, b, and care:

2.8.1 The AFD shall be maintained within the target band about the target flux difference. The AFD target bands for COS1 and COS2 are provided in Table 2.8.1.

2.8.2 The AFD may deviate outside the target band with THERMAL POWER < 90%

RTP but~ 50% RTP, provided AFD is within the acceptable operation limits specified in Figure 2.8.2.

Page A-30 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Table 2.8.1 CAOC Axial Flux Difference Operating Bands a,c Page A-31 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 Figure 2.8.2 Axial Flux Difference Acceptable Operation Limits

_a,c Page A-32 of 34

2.9 Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 On-Line Power Distribution Monitoring System (OPDMS)-Monitored Parameters (LCO 3.2.5) 2.9.1 The Peak Linear Heat Rate (PLHR) shall not exceed [

]a,c, as confirmed by Minimum Power Margin (MPM) > 0.0%, in MODE 1 with THERMAL POWER ~ 25% RTP and with the OPDMS functional.

Note: The PLHR limit presented here is based on the hot fuel height.

2.9.2 The Nuclear Enthalpy Rise Hot Channel Factor (F~H) shall not exceed its limits, as confirmed by MPM > 0.0%, in MODE 1 with THERMAL POWER

~ 25% RTP and with the OPDMS functional. The F~H limits are:

F~H= F~~P * (1 + PFtiH * (1 - P))

where: p THERMAL POWER

= RATED THERMAL POWER PF tiH = 0.3 2.9.3 The Departure from Nucleate Boiling Ratio (DNBR) shall be maintained greater than or equal to [

]a,c, as confirmed by MPM > 0.0%, in MODE 1 with THERMAL POWER ~ 25% RTP and with the OPDMS functional.

2.9.4 The SHUTDOWN MARGIN (SOM) shall be greater than or equal 1.6%.b.k/k, as confirmed by Excess Shutdown Margin > 0.0 ppm RCS boron concentration, in MODE 1 with the OPDMS functional and in MODE 2 with kett ~ 1.0 with the OPDMS functional.

Page A-33 of 34

Westinghouse Non-Proprietary Class 3 CORE OPERATING LIMITS REPORT FOR VOGTLE UNIT 3 CYCLE 2 2.10 RCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB)

Limits (LCO 3.4.1)

The RCS DNB parameter limits are:

2.10.1 The Pressurizer Pressure shall be maintained greater than or equal to

[

]a,c in MODE 1.

2.10.2 The RCS Average Temperature (Tav9) shall be maintained less than or equal to

[

]a,c in MODE 1.

2.10.3 The RCS total flow rate shall be maintained greater than or equal to 301,670 gpm in MODE 1.

2.11 Boron Concentration (LCO 3.9.1)

The limit in MODE 6 for the boron concentration of the RCS, the fuel transfer canal (when connected to the RCS), and the refueling cavity (when connected to the RCS) is:

2.11.1 The boron concentration shall be maintained greater than or equal to

[

]a,c Note: The limit bounds the BOL condition of kett::; 0.95 (all Rod Control Cluster Assemblies inserted, all Gray Rod Control Assemblies withdrawn) and subcriticality (all rods withdrawn) over the entire cycle. This limit includes additional boron to address uncertainties and B10 depletion.

Page A-34 of 34

Southern Nuclear Operating Company NL-24-0408 Vogtle Electric Generating Plant (VEGP) Unit 3 Westinghouse Application for Withholding Proprietary Information from Public Disclosure CAW-24-047 and accompanying Affidavit (This Enclosure consists of 4 pages, including this cover page)

Commonwealth of Pennsylvania:

County of Butler:

Westinghouse Non-Proprietary Class 3 AFFIDAVIT CAW-24-047 (1)

I, Zachary Harper, Consulting Engineer, Licensing, have been specifically delegated and authorized to apply for withholding and execute this Affidavit on behalf of Westinghouse Electric Company LLC (Westinghouse).

(2)

I am requesting the proprietary portions of CE-24-317, Revision 0 be withheld from public disclosure under l 0 CFR 2.390.

(3)

I have personal knowledge of the criteria and procedures utilized by Westinghouse in designating information as a trade secret, privileged, or as confidential commercial or financial information.

Page 1 of3 (4)

Pursuant to 10 CFR 2.390, the following is furnished for consideration by the Commission in determining whether the information sought to be withheld from public disclosure should be withheld.

(i)

The information sought to be withheld from public disclosure is owned and has been held in confidence by Westinghouse and is not customarily disclosed to the public.

(ii)

The information sought to be withheld is being transmitted to the Commission in confidence and, to Westinghouse's knowledge, is not available in public sources.

(iii)

Westinghouse notes that a showing of substantial harm is no longer an applicable criterion for analyzing whether a document should be withheld from public disclosure. Nevertheless, public disclosure of this proprietary information is likely to cause substantial harm to the competitive position of Westinghouse because it would enhance the ability of competitors to provide similar technical evaluation justifications and licensing defense services for commercial power reactors without commensurate expenses. Also, public disclosure of the information would enable others to use the information to meet NRC requirements for licensing documentation without purchasing the right to use the information.

Westinghouse Non-Proprietary Class 3 AFFIDAVIT CAW-24-047 (5)

Westinghouse has policies in place to identify proprietary information. Under that system, information is held in confidence if it falls in one or more of several types, the release of which might result in the loss of an existing or potential competitive advantage, as follows:

(a)

The information reveals the distinguishing aspects of a process ( or component, structure, tool, method, etc.) where prevention of its use by any of Westinghouse's competitors without license from Westinghouse constitutes a competitive economic advantage over other companies.

Page 2 of3 (b)

It consists of supporting data, including test data, relative to a process ( or component, structure, tool, method, etc.), the application of which data secures a competitive economic advantage (e.g., by optimization or improved marketability).

( c)

Its use by a competitor would reduce his expenditure of resources or improve his competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing a similar product.

( d)

It reveals cost or price information, production capacities, budget levels, or commercial strategies of Westinghouse, its customers or suppliers.

(e)

It reveals aspects of past, present, or future Westinghouse or customer funded development plans and programs of potential commercial value to Westinghouse.

(f)

It contains patentable ideas, for which patent protection may be desirable.

(6)

The attached documents are bracketed and marked to indicate the bases for withholding. The justification for withholding is indicated in both versions by means of lower-case letters (a) through (f) located as a superscript immediately following the brackets enclosing each item of information being identified as proprietary or in the margin opposite such information. These lower-case letters refer to the types of information Westinghouse customarily holds in confidence identified in Sections (5)(a) through (f) of this Affidavit.

Westinghouse Non-Proprietary Class 3 AFFIDAVIT CAW-24-047 I declare that the averments of fact set forth in this Affidavit are true and correct to the best of my knowledge, information, and belief. I declare under penalty of perjury that the foregoing is true and correct.

Executed on: 9/27/2024 Signed electronically by Zachary Harper Page 3 of3