We request that all examination materials related to the ANO Unit 2 2023 NRC Operator License Examinations be withheld from public disclosure for a period of two years.

2CAN032305 2023 ILO NRC Written Exam Applicant Questions and Comments during Exam

2023 Unit 2 ILO NRC Written Exam Administered March 15th, 2023 APPLICANT QUESTIONS AND RESPONSES QID#

TIME APPLICANT NAME/DOCKET #

APPLICANT QUESTION/COMMENT PROCTOR RESPONSE 8

0937 Brandon Tribble/55-72723 Is this failure on the input or output of the controller?

The conditions and stem of the question were read back to the applicant. No further information was provided. The conditions state that the failure is from the pressure transmitter, which is the input to the controller.

42 1042 Caleb Walker/55-76377 Do I assume current plant alignment?

The conditions and the stem were read back to the applicant. No additional information was provided. From the

briefing, the applicants are not to assume any additional failures or plant alignments unless specifically stated in the stem or conditions of the question.

81 1137 Brandon Tribble/55-72723 The question stem refers to regulated voltage but the reference refers to unregulated voltage points. What are the unregulated voltage values?

After a discussion with the exam team, determined that the applicant did not need unregulated voltage to answer the question (the applicant can deduce the values from the information given).

No additional information was provided.

21 1141 Josef Nichols/55-76378 Do I consider the plant conditions in the stem to determine which radiation monitor to use or do I just answer based on what the Annunciator Corrective Action says?

The conditions and the stem were read back to the applicant. No additional

information was provided. The conditions of the question render one of the radiation monitors incapable of monitoring radiation.

25 1143 Josef Nichols/55-76378 Do I consider the rate of Containment sump level rise as a leakrate?

The conditions and the stem were read back to the applicant. No addition information was provided. The question conditions state that the sump is rising at 10 gpm, not that a leakrate has been performed.

24 1301 Kyle Rollans/55-76375 Sometimes we drain the sump and sometimes we drain to the Hold-Up tank.

Which do I consider to be normal?

The conditions and stem were read back to the applicant. No additional information was provided. The conditions in the stem determine

which method is used (at normal full power).

99 1303 Brandon Tribble/55-72723 When answering this question, do I consider the situation in which the SM becomes incapacitated?

The conditions and stem were read back to the applicant. No additional information was provided. The stem of the question does not ask about when the SM becomes incapacitated. It asks about when the SM can delegate authority.

67 1408 Kyle Rollans/55-76375 What does most limiting Tech Spec action mean? Does that mean the action that has the shortest time to take an action or does that mean the action that will place the plant in Mode 3 the fastest?

The conditions and stem were read back to the applicant. No additional information was provided. The stem of the question asks about the most limiting tech spec action (1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or less action) which also

corresponds to having to be in Mode 3 within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

This information did not need to be clarified to answer the question.

28 1409 Brian Pawlowski/55-73399 What is the noun name for 2F-3A/B in answer choice A?

After a discussion with the exam team and referring to the procedure noun name for 2PSV-4800 and looking at the question, the noun name for 2F-3A/B was not needed to answer the question.

There is only one set of filters in the CVCS system. No additional information was provided.

72 1439 Kyle Rollans/55-76375 How long has the plant been stable?

This information was not needed to answer the question.

Read stem and answer choices to the applicant. No further information was provided.

71 1540 Brian Pawlowski/55-73399 Brian stated that he thought this question had two correct answers (B and C). He did not have a question only wanted to make this comment.

Recorded his comment and read question and answer choices to applicant.

No additional information was provided. Applicant was reading too much into distractor C.

We request that all examination materials related to the ANO Unit 2 2023 NRC Operator License Examinations be withheld from public disclosure for a period of two years.

2CAN032305 2023 ILO NRC Written Post-Exam Analysis

3/15/2023 Overall CORRECT R4 R1 R2 R3 I2 I1 I3 U1 U2 U3

% Missed 1

B 1

2 A

B B

B 30%

2 3

A 3

4 C

4 5

D 5

6 D

6 7

C 7

8 A

C 10%

8 9

A 9

10 C

10 11 B

11 12 C

12 13 B

D 10%

13 14 C

D 10%

14 15 D

15 16 B

16 17 D

B 10%

17 18 A

18 19 D

19 20 A

20 21 B

21 22 A

22 23 B

23 24 D

C B

20%

24 25 C

25 26 B

26 27 D

C C

C 30%

27 28 A

B C

20%

28 29 C

A D

20%

29 30 B

30 31 A

31 32 A

32 33 C

33 34 D

34 35 C

D 10%

35 36 C

36 37 D

37 38 B

C 10%

38 39 D

39 40 D

40 41 A

41 42 B

D D

A 30%

42 43 D

B 10%

43 44 B

44 45 B

45 2023 Unit 2 ILO NRC Exam Analysis RO SROI SROU

46 A

46 47 C

47 48 C

D 10%

48 49 A

B 10%

49 50 B

A A

20%

50 51 B

A 10%

51 52 A

52 53 C

A 10%

53 54 D

C 10%

54 55 D

C 10%

55 56 B

56 57 A

B 10%

57 58 B

58 59 B

A A

A 30%

59 60 D

60 61 B

D 10%

61 62 C

62 63 A

B B

20%

63 64 A

64 65 D

65 66 A

66 67 C

A A

A A

A A

60%

67 68 C

B D

B 30%

68 69 A

B 10%

69 70 D

B B

20%

70 71 B

A C

C 30%

71 72 C

A 10%

72 73 B

73 74 D

74 75 C

B B

B 30%

75 76 D

76 77 D

77 78 C

78 79 B

79 80 A

80 81 A

81 82 C

82 83 A

83 84 B

84 85 C

A 17%

85 86 A

86 87 B

A 17%

87 88 C

88 89 D

B 17%

89 90 B

90 91 A

91 92 D

92 93 A

D B

C 50%

93 94 D

94

95 B

95 96 C

96 97 B

C A

C A

67%

97 98 C

D B

33%

98 99 C

A 17%

99 100 D

100 96.0 88.0 97.0 98.0 92.0 96.0 86.6 94.6 88.0 84.0 91.0 88.0 97.0 99.0 98.0 92.2 Class Avg 91.3 RO Avg 92.8 SRO Avg OVERALL Avg 84.0 88.0 84.0 96.0 100.0 96.0 SRO section 91.3 96.0 86.6 94.6 88.0 84.0 92.0 89.3 97.3 98.6 98.6 RO section 92.5

We request that all examination materials related to the ANO Unit 2 2023 NRC Operator License Examinations be withheld from public disclosure for a period of two years.

2CAN032305 2023 ILO NRC Written Post-Exam Analysis Tier 4 Only

3/15/2023 Overall CORRECT R4 R1*

R2 R3 I2 I1 I3 U1 U2 U3

% Missed 70 D

B B

20%

70 71 B

A C

C 30%

71 72 C

A 10%

72 73 B

73 74 D

74 75 C

B B

B 30%

75

  • R1 did NOT take NRC GFES exam 2023 Unit 2 ILO NRC Exam Analysis-TIER 4 GFES SECTION RO SROI SROU

We request that all examination materials related to the ANO Unit 2 2023 NRC Operator License Examinations be withheld from public disclosure for a period of two years.

2CAN032305 2023 ILO NRC Written Exam Post-Exam Applicant Comments

2023 Unit 2 ILO NRC Written Exam Administered March 15th, 2023 POST-EXAM APPLICANT COMMENTS Below are the applicant post-exam comments concerning the NRC Written Exam.

QID#

MISS RATE APPLICANT COMMENTS 67 60%

During post-exam review, applicants stated the following reasons for answering this question incorrectly:

Incorrectly applied Tech Spec action for Minimum Temperature for Criticality rather than the Tech Spec for Tcold Did not recall that RWT boron concentration had an upper limit of 3000 ppm (thought Tech Spec LCO was just greater than 2500 ppm with no upper limit)

Applicants agreed this was a valid question with the approved answer key being correct.

93 50%

During post-exam review, applicants stated the following reasons for answering this question incorrectly:

Applicants did not recall the procedural requirement of 10% power change requirement to be High Risk reactivity management evolution. Rationalized 5%

as being correct when the procedural limit could not be recalled.

Applicants did not recall 5.3 HgA limit in the normal operating procedure for condenser vacuum. Incorrectly applied Loss of Condenser Vacuum AOP limit of 5.15 HgA for AOP exit.

Applicants agreed that this was a valid question with the approved answer key being correct.

97 67%

During post-exam review, applicants stated the following reasons for answering this question incorrectly:

Applicants incorrectly determined that a eSOMS Component deviation record was required to be performed. This is not a requirement of OP-3305.002.

Applicants incorrectly determined that a removed from service marker was required to be placed on the window whenever the procedure OP-3305.002 directs to NOT place removed from service marker on window due to it being a reflash annunciator. Applicant stated that they read too much into this question and did not recall the procedural requirement.

Applicants agreed that this was a valid question with the approved answer key being correct.

We request that all examination materials related to the ANO Unit 2 2023 NRC Operator License Examinations be withheld from public disclosure for a period of two years.

2CAN032305 2023 ILO NRC Written Exam Seating Chart

2023 Unit 2 ILO NRC Written Exam Administered March 15th, 2023 Seating Chart (Front: West)

Proctors SRO Alexander RO Walker SRO Wyett SRO Nichols RO Rollans RO Davis SRO Hendrix SRO Pawlowski RO Kendrick SRO Tribble

We request that all examination materials related to the ANO Unit 2 2023 NRC Operator License Examinations be withheld from public disclosure for a period of two years.

2CAN032305 2023 ILO NRC Written Exam Post-Exam Performance Analysis Results

2023 Unit 2 ILO NRC Written Exam Administered March 15th, 2023 PERFORMANCE ANALYSIS FOR WRITTEN EXAM The threshold for determination of questions to be analyzed was a miss rate of 50% or higher.

Below are the applicant comments concerning these questions and the results of the exam analysis.

QID#

MISS RATE APPLICANT COMMENTS ANALYSIS RESULT 67 60%

During post-exam review, applicants stated the following reasons for answering this question incorrectly:

Incorrectly applied Tech Spec action for Minimum Temperature for Criticality rather than the Tech Spec for Tcold Did not recall that RWT boron concentration had an upper limit of 3000 ppm (thought Tech Spec LCO was just greater than 2500 ppm with no upper limit)

Applicants agreed this was a valid question with the approved answer key being correct.

ANO Unit 2 recommends that this answer should not be changed and the question should not be deleted or modified.

WTANO-2022-239 CA 24 initiated to perform a training needs analysis to address this knowledge deficiency.

93 50%

During post-exam review, applicants stated the following reasons for answering this question incorrectly:

Applicants did not recall the procedural requirement of 10% power change requirement to be High Risk reactivity management evolution. Rationalized 5% as being correct when the procedural limit could not be recalled.

Applicants did not recall 5.3 HgA limit in the normal operating procedure for condenser vacuum. Incorrectly applied Loss of Condenser Vacuum AOP limit of 5.15 HgA for AOP exit.

Applicants agreed that this was a valid question with the approved answer key being correct.

ANO Unit 2 recommends that this answer should not be changed and the question should not be deleted or modified.

WTANO-2022-239 CA25 initiated to perform a training needs analysis to address this knowledge deficiency.

97 67%

During post-exam review, applicants stated the following reasons for answering this question incorrectly:

Applicants incorrectly determined that a eSOMS Component deviation record was required to be performed. This is not a requirement of OP-3305.002.

Applicants incorrectly determined that a removed from service marker was required ANO Unit 2 recommends that this answer should not be changed and the question should not be deleted or modified.

WTANO-2022-239 CA26 initiated to perform a training needs analysis to address this knowledge deficiency.

to be placed on the window whenever the procedure OP-3305.002 directs to NOT place removed from service marker on window due to it being a reflash annunciator.

Applicant stated that they read too much into this question and did not recall the procedural requirements.

Applicants agreed that this was a valid question with the approved answer key being correct.

We request that all examination materials related to the ANO Unit 2 2023 NRC Operator License Examinations be withheld from public disclosure for a period of two years.

2CAN032305 2023 ILO NRC Written Exam Training Analysis Corrective Actions

CORRECTIVE ACTION WT-WTANO-2022-00239 Closure Comments:

Subresponse :

Response

Originated By:

Performed By:

Subperformed By:

Approved By:

Closed By:

Assigned By:

Assigned To:

Subassigned To :

CA Number:

24 Initial Due Date: 06/02/2023 CA Type:

Plant Constraint:

CA

Description:

TRAINING ACTION TRAINING TRACKING Current Due Date: 06/01/2023 Action:

Perform a training screening and a training needs analysis as necessary for the high missed question on the 2023 Unit 2 NRC ILO Exam for the following K/A to address this knowledge deficiency.

(G2.2.39) Equipment Control: Knowledge of less than or equal to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> TS action statements (does not include action statements of 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or less that follow the expiration of a completion time for a TS condition for which an action statement has already been entered)

This high missed question was covered with the 2023 Unit 2 ILO Class during the exam debrief to ensure all gaps associated with this question was closed.

3/30/2023 09:21:44 Rowbotham,Theron Group Name Harris,James P Rowbotham,Theron Training Operations Staff ANO Training Operations Staff ANO ANO ANO Site NOT USED CA Priority:

CORRECTIVE ACTION WT-WTANO-2022-00239 Closure Comments:

Subresponse :

Response

Originated By:

Performed By:

Subperformed By:

Approved By:

Closed By:

Assigned By:

Assigned To:

Subassigned To :

CA Number:

25 Initial Due Date: 06/09/2023 CA Type:

Plant Constraint:

CA

Description:

TRAINING ACTION TRAINING TRACKING Current Due Date: 06/08/2023 Action:

Perform a training screening and a training needs analysis as necessary for the high missed question on the 2023 Unit 2 NRC ILO Exam for the following K/A to address this knowledge deficiency.

(075)(SF8 CW) CIRCULATING WATER SYSTEM (G2.1.37) CONDUCT OF OPERATIONS: Knowledge of procedures, guidelines, or limitations associated with reactivity management.

This high missed question was covered with the 2023 Unit 2 ILO Class during the exam debrief to ensure all gaps associated with this question was closed.

3/30/2023 09:25:11 Rowbotham,Theron Group Name Harris,James P Rowbotham,Theron Training Operations Staff ANO Training Operations Staff ANO ANO ANO Site NOT USED CA Priority:

CORRECTIVE ACTION WT-WTANO-2022-00239 Closure Comments:

Subresponse :

Response

Originated By:

Performed By:

Subperformed By:

Approved By:

Closed By:

Assigned By:

Assigned To:

Subassigned To :

CA Number:

26 Initial Due Date: 06/02/2023 CA Type:

Plant Constraint:

CA

Description:

TRAINING ACTION TRAINING TRACKING Current Due Date: 06/01/2023 Action:

Perform a training screening and a training needs analysis as necessary for the high missed question on the 2023 Unit 2 NRC ILO Exam for the following K/A to address this knowledge deficiency.

(G2.2.43) EQUIPMENT CONTROL: Knowledge of the process used to track inoperable alarms.

This high missed question was covered with the 2023 Unit 2 ILO Class during the exam debrief to ensure all gaps associated with this question was closed.

3/30/2023 09:27:39 Rowbotham,Theron Group Name Harris,James P Rowbotham,Theron Training Operations Staff ANO Training Operations Staff ANO ANO ANO Site NOT USED CA Priority: