ULNRC-06765, License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate Testing Frequencies (LDCN 2020-0004)

From kanterella
(Redirected from ML22307A311)
Jump to navigation Jump to search
License Amendment Request to Revise Technical Specification 5.5.16, Containment Leakage Rate Testing Program, for Permanent Extension of Type a and Type C Leak Rate Testing Frequencies (LDCN 2020-0004)
ML22307A311
Person / Time
Site: Callaway 
(NPF-030)
Issue date: 11/03/2022
From: Bianco F
Ameren Missouri, Union Electric Co
To:
Office of Nuclear Reactor Regulation, Document Control Desk
Shared Package
ML22307A310 List:
References
ULNRC-06765
Download: ML22307A311 (1)


Text

.

.t

.t

.t Callaway Plant 8315 County Road 459 : Steedman, MO 65077 : AmerenMissouri.com

.t November 3, 2022 ULNRC-06765 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 10 CFR 50.90 Ladies and Gentlemen:

DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT 1 UNION ELECTRIC CO.

RENEWED FACILITY OPERATING LICENSE NPF-30 LICENSE AMENDMENT REQUEST TO REVISE CALLAWAY PLANT, UNIT 1 TECHNICAL SPECIFICATION 5.5.16, "CONTAINMENT LEAKAGE RATE TESTING PROGRAM," FOR PERMANENT EXTENSION OF TYPE A AND TYPE C LEAK RATE TEST FREQUENCIES (LDCN 2020-0004)

Pursuant to 10 CFR 50.90, Application for amendment of license or construction permit, Ameren Missouri (Union Electric Company) herewith transmits an application for amendment to Facility Operating License Number NPF-30 for the Callaway Plant. The proposed change revises Callaway Plant's Technical Specification (TS) 5.5.16, "Containment Leakage Rate Testing Program," to allow for the permanent extension of the Type A Integrated Leak Rate Testing (ILRT) and Type C Leak Rate Testing frequencies based on the guidance in NEI 94-01, " Industry Guideline for Implementing Performance-Based Option of 10 CFR 50, Appendix J," (Rev. 3-A).

Specifically, the proposed change will revise Callaway Plant's TS 5.5.16 by replacing the references to Regulatory Guide 1.163, "Performance-Based Containment Leak-Test Program," with a reference to NEI 94-01, Revision 3-A, dated July, 2012, and the limitations and conditions specified in NEI 94-01, Revision 2-A, dated October 2008, as the documents used to implement the performance-based containment leakage testing program in accordance with Option B of 10 CFR 50, Appendix J, "Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors."

The proposed amendment is risk-informed and follows the guidance in RG 1.174, "An Approach for Using Probabilistic Risk Assessment in Risk-Informed Decisions on Plant-Specific Changes to the Licensing Basis," Revision 2.

The enclosure to this letter provides the evaluation of the proposed change and contains attachments that provide the evaluation of risk significance of permanent ILRT extension, the markup of the affected TS pages, and re-typed clean-copy TS pages.

~~

WAmeren MISSOURI

ULNRC-06765 November 3, 2022 Page 2 of 4 It has been determined that this amendment application does not involve a significant hazard consideration as determined per 10 CFR 50.92, "Issuance of amendment." Pursuant to 10 CFR 51.22, "Criterion categorical exclusion or otherwise not requiring environmental review," Section (b ), no environmental impact statement or environmental assessment need be prepared in connection with the issuance of this amendment.

Further, this submittal does not contain new commitments.

The Callaway Onsite Review Committee has reviewed and approved the proposed changes and has approved the submittal of this amendment application.

Ameren Missouri requests approval of the requested license amendment prior to October 11, 2023.

This requested approval date will support timely extension of the ILRT, which is next required to be performed during the outage in the fall of 2023, if performed per the current (unextended) interval.

Ameren Missouri further requests that the license amendment be made effective upon NRC issuance, to be implemented within 90 days from the date of issuance.

In accordance with 10 CFR 50.91 "Notice for public comment; State consultation," Section (b)(l), a copy of this amendment application is being provided to the designated Missouri State official.

If there are any questions, please contact Tom Elwood at 314-225-1905.

I declare under penalty of perjury that the foregoing is true and correct Executed on: _ t~{ ~h

___ J_~_- _~J...._

Enclosure:

Evaluation of the Proposed Change Attachments to the

Enclosure:

Senior Director, Nuclear Operations

1. Evaluation of Risk Significance of Permanent ILR T Extension
2. Proposed Technical Specification 5.5.16 Changes (Markup)
3. Proposed Technical Specification 5.5.16 Changes (Clean Pages)

ULNRC-06765 November 3, 2022 Page 3 of 4 cc:

Mr. Scott A. Morris Regional Administrator U. S. Nuclear Regulatory Commission Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 Senior Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission 8201 NRC Road Steedman, MO 65077 Mr. Mahesh Chawla Project Manager, Callaway Plant Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Mail Stop O8B1A Washington, DC 20555-0001

ULNRC-06765 November 3, 2022 Page 4 of 4 Index and send hardcopy to QA File A160.0761 Hardcopy:

Certrec Corporation 6500 West Freeway, Suite 400 Fort Worth, TX 76116 (Certrec receives ALL attachments as long as they are non-safeguards and may be publicly disclosed.)

Electronic distribution for the following can be made via Tech Spec ULNRC Distribution:

F. M. Diya B. L. Cox F. J. Bianco B. L. Jungmann D. E. Farnsworth D. S. Pallardy T. A. Witt T. B. Elwood NSRB Secretary STARS Regulatory Affairs Mr. Jay Silberg (Pillsbury Winthrop Shaw Pittman LLP)

Ms. Claire Eubanks (Missouri Public Service Commission)

Mr. Aaron Schmidt (DNR)