Weld Residual Stress Finite Element Analysis Validation Part IIProposed Validation Procedure Final Report Office of Nuclear Regulatory Research NUREG-2228
AVAILABILITY OF REFERENCE MATERIALS IN NRC PUBLICATIONS NRC Reference Material As of November 1999, you may electronically access NUREG-series publications and other NRC records at NRCs Library at www.nrc.gov/reading-rm.html. Publicly released records include, to name a few, NUREG-series publications; Federal Register notices; applicant, licensee, and vendor documents and correspondence; NRC correspondence and internal memoranda; bulletins and information notices; inspection and investigative reports; licensee event reports; and Commission papers and their attachments.
NRC publications in the NUREG series, NRC regulations, and Title 10, Energy, in the Code of Federal Regulations may also be purchased from one of these two sources.
- 1. The Superintendent of Documents U.S. Government Publishing Office Washington, DC 20402-0001 Internet: bookstore.gpo.gov Telephone: (202) 512-1800 Fax: (202) 512-2104
- 2. The National Technical Information Service 5301 Shawnee Road Alexandria, VA 22312-0002 www.ntis.gov 1-800-553-6847 or, locally, (703) 605-6000 A single copy of each NRC draft report for comment is available free, to the extent of supply, upon written request as follows:
Address: U.S. Nuclear Regulatory Commission
Office of Administration Multimedia, Graphics, and Storage &
Distribution Branch Washington, DC 20555-0001 E-mail: distribution.resource@nrc.gov Facsimile: (301) 415-2289 Some publications in the NUREG series that are posted at NRCs Web site address www.nrc.gov/reading-rm/
doc-collections/nuregs are updated periodically and may differ from the last printed version. Although references to material found on a Web site bear the date the material was accessed, the material available on the date cited may subsequently be removed from the site.
Non-NRC Reference Material Documents available from public and special technical libraries include all open literature items, such as books, journal articles, transactions, Federal Register notices, Federal and State legislation, and congressional reports.
Such documents as theses, dissertations, foreign reports and translations, and non-NRC conference proceedings may be purchased from their sponsoring organization.
Copies of industry codes and standards used in a substantive manner in the NRC regulatory process are maintained at The NRC Technical Library Two White Flint North 11545 Rockville Pike Rockville, MD 20852-2738 These standards are available in the library for reference use by the public. Codes and standards are usually copyrighted and may be purchased from the originating organization or, if they are American National Standards, from American National Standards Institute 11 West 42nd Street New York, NY 10036-8002 www.ansi.org (212) 642-4900 Legally binding regulatory requirements are stated only in laws; NRC regulations; licenses, including technical specifications; or orders, not in NUREG-series publications.
The views expressed in contractor prepared publications in this series are not necessarily those of the NRC.
The NUREG series comprises (1) technical and administrative reports and books prepared by the staff (NUREG-XXXX) or agency contractors (NUREG/CR-XXXX),
(2) proceedings of conferences (NUREG/CP-XXXX),
(3) reports resulting from international agreements (NUREG/IA-XXXX),(4) brochures (NUREG/BR-XXXX), and (5) compilations of legal decisions and orders of the Commission and Atomic and Safety Licensing Boards and of Directors decisions under Section 2.206 of NRCs regulations (NUREG-0750).
DISCLAIMER: This report was prepared as an account of work sponsored by an agency of the U.S. Government.
Neither the U.S. Government nor any agency thereof, nor any employee, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for any third partys use, or the results of such use, of any information, apparatus, product, or process disclosed in this publication, or represents that its use by such third party would not infringe privately owned rights.
Weld Residual Stress Finite Element Analysis Validation Part IIProposed Validation Procedure Final Report Manuscript Completed: January 2020 Date Published: July 2020 Prepared by:
M. Benson P. Raynaud J. Wallace U.S. Nuclear Regulatory Commission Michael Benson, NRC Project Manager Office of Nuclear Regulatory Research NUREG-2228
iii ABSTRACT Under a Memorandum of Understanding, the U.S. Nuclear Regulatory Commission and the Electric Power Research Institute conducted a research program aimed at gathering data on weld residual stress modeling. As described in NUREG-2162, Weld Residual Stress Finite Element Analysis Validation: Part IData Development Effort, issued March 2014, this program consisted of round robin measurement and modeling studies on various mockups. At that time, the assessment of the data was qualitative. This report describes an additional residual stress round robin study and a methodology for capturing residual stress uncertainties. This quantitative approach informed the development of guidelines and a validation methodology for finite element prediction of weld residual stress. For example, comparisons of modeling results to measurements provided a basis for establishing guidance on a material hardening approach for residual stress models. The proposed validation procedure involves an analyst modeling a known case (the Phase 2b round robin mockup) and comparing results to two proposed quality metrics.
These recommendations provide a potential method by which analysts can bolster confidence in their modeling practices for regulatory applications.
v TABLE OF CONTENTS ABSTRACT................................................................................................................... iii LIST OF FIGURES......................................................................................................... ix LIST OF TABLES.......................................................................................................... xi EXECUTIVE
SUMMARY
............................................................................................. xiii ACKNOWLEDGMENTS............................................................................................... xv ABBREVIATIONS AND ACRONYMS........................................................................ xvii 1
INTRODUCTION................................................................................................... 1-1 1.1 Phase 2b Effort............................................................................................................... 1-1 1.2 Scope of This Report..................................................................................................... 1-2 2
PHASE 2B ROUND ROBIN STUDY..................................................................... 2-1 2.1 Purpose.......................................................................................................................... 2-1 2.2 Mockup Fabrication........................................................................................................ 2-1 2.3 Round Robin Participants.............................................................................................. 2-4 2.4 Weld Residual Stress Measurements........................................................................... 2-4 2.5 Modeling Guidance........................................................................................................ 2-7 2.6 Results............................................................................................................................ 2-9 2.6.1 Measurement Results..................................................................................... 2-9 2.6.2 Modeling Results........................................................................................... 2-10 2.6.3 Discussion..................................................................................................... 2-12 2.7 Conclusions.................................................................................................................. 2-12 3
UNCERTAINTY QUANTIFICATION METHODOLOGY........................................ 3-1 3.1 Motivation....................................................................................................................... 3-1 3.2 Methodology................................................................................................................... 3-2 3.2.1 Functional Data............................................................................................... 3-2 3.2.2 Screening of Outlier Predictions...................................................................... 3-2 3.2.3 Data Smoothing............................................................................................... 3-2 3.2.4 Amplitude and Phase Variability..................................................................... 3-3 3.2.5 Modeling Amplitude and Phase Variability...................................................... 3-4 3.2.6 Bootstrapping................................................................................................... 3-5 3.2.7 Uncertainty Characterization of the Measurement Data................................ 3-5 3.2.8 Tolerance Bounds versus Confidence Bounds.............................................. 3-6 3.3 Results............................................................................................................................ 3-6
vi 3.3.1 Uncertainty Quantification for the Prediction Data.......................................... 3-6 3.3.2 Uncertainty Quantification for the Deep Hole Drilling Measurement Data............................................................................................................... 3-11 3.3.3 Uncertainty Quantification for the Contour Measurement Data.................... 3-15 3.4 Conclusions.................................................................................................................. 3-16 4
WRS IMPACT ON FLAW GROWTH CALCULATIONS........................................ 4-1 4.1 Regulatory Application................................................................................................... 4-1 4.2 Inputs.............................................................................................................................. 4-3 4.3 Superposition of Stresses.............................................................................................. 4-3 4.4 Stress Intensity Factor and Crack Growth..................................................................... 4-4 4.5 Flaw Growth Results...................................................................................................... 4-6 4.6 Discussion...................................................................................................................... 4-8 4.7 Conclusion.................................................................................................................... 4-11 5
VALIDATION PROCEDURE AND FINITE ELEMENT GUIDELINES................... 5-1 5.1 Introduction..................................................................................................................... 5-1 5.2 Material Hardening Law................................................................................................. 5-1 5.2.1 Difference in Means and Root Mean Square Error Functions....................... 5-1 5.2.2 Assessment of Prediction Trends................................................................... 5-2 5.2.3 Assessment of Root Mean Square Error........................................................ 5-8 5.2.4 Hardening Law Recommendation................................................................. 5-10 5.3 Modeling Guidelines..................................................................................................... 5-10 5.4 Proposed Validation Scheme....................................................................................... 5-12 5.4.1 Overview of Approach................................................................................... 5-12 5.4.2 Benchmark..................................................................................................... 5-13 5.4.3 Circumferential Flaw Growth - Isotropic Hardening..................................... 5-14 5.4.4 Circumferential Flaw Growth - Average Hardening..................................... 5-16 5.4.5 Axial Flaw Growth - Isotropic Hardening...................................................... 5-17 5.4.6 Axial Flaw Growth - Average Hardening...................................................... 5-20 5.4.7 Overview of Quality Metrics........................................................................... 5-21 5.4.8 Quality Metrics for Axial Stress Predictions.................................................. 5-22 5.4.9 Recommended Acceptance Measures - Axial Residual Stress.................. 5-24 5.4.10 Quality Metrics for Hoop Stress Predictions................................................. 5-24 5.4.11 Recommended Acceptance Measures - Hoop Residual Stress................. 5-28 5.5 Summary of Validation Procedure............................................................................... 5-28 5.6 Modeling a Nuclear Plant Application.......................................................................... 5-30
vii 5.6.1 Applicability of Validation Scheme and Acceptance Measures.................... 5-30 5.6.2 Welding Process............................................................................................ 5-31 5.6.3 Hardening Law.............................................................................................. 5-31 5.6.4 Best Practices for a Plant Application........................................................... 5-32 5.7 Conclusion.................................................................................................................... 5-32 6
CONCLUSIONS.................................................................................................... 6-1 7
REFERENCES...................................................................................................... 7-1 MODEL-MEASUREMENT COMPARISONS..................................... A-1 MATERIAL PROPERTIES................................................................. B-1 DATA FOR VALIDATION PROCESS............................................... C-1 ANALYSIS OF VALIDATION METRICS FOR AVERAGE HARDENING...................................................................................... D-1 ANALYSIS OF VALIDATION METRICS FOR ISOTROPIC HARDENING...................................................................................... E-1 APPENDIX A APPENDIX B APPENDIX C APPENDIX D APPENDIX E
ix LIST OF FIGURES Figure 2-1 Phase 2b Mockup Geometry (Dimensions in inches [millimeters])....................... 2-2 Figure 2-2 ID Backweld............................................................................................................ 2-3 Figure 2-3 Participating Organizations..................................................................................... 2-4 Figure 2-4 Deep Hole Drilling Measurement Setup................................................................. 2-5 Figure 2-5 Hole Drilling Measurements around Circumference.............................................. 2-5 Figure 2-6 Contour Measurement Setup................................................................................. 2-6 Figure 2-7 Cuts to Extract Contour Specimen......................................................................... 2-7 Figure 2-8 Hole Drilling Measurement: (a) Axial, (b) Hoop...................................................... 2-9 Figure 2-9 Hoop StressContour Measurement.................................................................... 2-9 Figure 2-10 Axial StressContour Measurement................................................................... 2-10 Figure 2-11 Example Mesh...................................................................................................... 2-11 Figure 2-12 Processed Isotropic Hardening Results: (a) Axial, (b) Hoop............................... 2-12 Figure 2-13 Processed Nonlinear Kinematic Hardening Results: (a) Axial, (b) Hoop............ 2-12 Figure 3-1 Axial Isotropic Data after Smoothing...................................................................... 3-3 Figure 3-2 Amplitude and Phase Variability............................................................................. 3-3 Figure 3-3 Axial Isotropic Data after Alignment....................................................................... 3-4 Figure 3-4 100 Sampled WRS Curves Based upon Round Robin Modeling Data................. 3-5 Figure 3-5 Contour Axial Stress Data...................................................................................... 3-6 Figure 3-6 Constructing Confidence Bounds on the Mean (Axial, Isotropic Case): (a) 30 of the 1,000 Bootstrap Sample Means and (b) Resulting Confidence Bounds.................................................................................................................... 3-7 Figure 3-7 Constructing Tolerance Bounds (Axial, Isotropic Case): (a) 30 of the 1,000 Bootstrap 2.5th and 97.5th Quantiles and (b) Resulting Tolerance Bounds........... 3-8 Figure 3-8 Bootstrap Tolerance Bounds on Isotropic Hoop Stress Predictions: (a) With Potential Outlier and (b) Without Potential Outlier............................................... 3-10 Figure 3-9 Data Smoothing for Axial DHD Data: (a) Raw Data, (b) Smoothed Data, and (c) Residuals.................................................................................................. 3-12 Figure 3-10 Confidence Bounds on the Mean (Axial DHD Data)............................................ 3-13 Figure 3-11 Tolerance Bounds (Axial DHD Data).................................................................... 3-13 Figure 3-12 Confidence Bounds on Mean (Hoop DHD Data)................................................. 3-14 Figure 3-13 Tolerance Bounds (Hoop DHD Data)................................................................... 3-14 Figure 3-14 50 Extracted Stress Profiles................................................................................. 3-15 Figure 3-15 Tolerance Bounds for Axial Contour Data............................................................ 3-16 Figure 4-1 ASME Code Flaw Disposition Procedure............................................................... 4-1 Figure 4-2 Analytical Flaw Evaluation Procedure.................................................................... 4-2 Figure 4-3 Loads from Various Sources.................................................................................. 4-3 Figure 4-4 Superposition of Membrane, Crack-Face Pressure, and Weld Residual Stresses.................................................................................................................. 4-4 Figure 4-5 SIF at Two Locations along Crack Front................................................................ 4-5 Figure 4-6 (a) K90 and (b) Growth in Depth Direction............................................................... 4-7 Figure 4-7 (a) K0 and (b) growth in length direction................................................................. 4-8 Figure 4-8 Flaw Growth after 20 Years.................................................................................... 4-9 Figure 4-9 (a) Membrane Stresses, (b) Area under the Curve.............................................. 4-10 Figure 5-1 Nonlinear Kinematic Hardening Predictions against the DHD Measurements: (a) Actual Data and (b) Mean Difference Function and Tolerance Bounds................................................................................................... 5-3 Figure 5-2 Isotropic Hardening Predictions against the DHD Measurements: (a) Actual Data and (b) Mean Difference Function and Tolerance Bounds........................... 5-5
x Figure 5-3 Average Hardening Predictions against the DHD Measurements: (a) Actual Data and (b) Mean Difference Function and Tolerance Bounds........................... 5-6 Figure 5-4 Root Mean Square Error for Axial Stress Predictions: (a) DHD Benchmark and (b) Contour Benchmark................................................................................... 5-9 Figure 5-5 Root Mean Square Error for Hoop Stress Predictions: (a) DHD Benchmark and (b) Contour Benchmark................................................................................. 5-10 Figure 5-6 Comparison of DHD and Contour Axial Stress Predictions (a) Raw Data and (b) Difference in Means................................................................................. 5-14 Figure 5-7 Smoothed Axial WRS Profiles and Mean, Isotropic Hardening........................... 5-15 Figure 5-8 Circumferential Flaw Growth, Isotropic Hardening.............................................. 5-15 Figure 5-9 Smoothed Axial WRS Profiles, Average Hardening............................................ 5-16 Figure 5-10 Circumferential Flaw Growth, Average Hardening............................................... 5-17 Figure 5-11 Smoothed Hoop WRS Profiles, Isotropic Hardening........................................... 5-18 Figure 5-12 Axial Flaw Growth, Isotropic Hardening............................................................... 5-19 Figure 5-13 Hoop WRS Profiles, Average Hardening............................................................. 5-20 Figure 5-14 Axial Flaw Growth, Average Hardening............................................................... 5-20 Figure 5-15 Stress Intensity Factor: (a) Isotropic Hardening and (b) Average Hardening...... 5-21 Figure 5-16 Prediction C (Isotropic) against the Mean Prediction........................................... 5-23 Figure 5-17 Hoop Stress Prediction from Participant G.......................................................... 5-26 Figure 5-18 Hoop Stress Prediction from Participant C........................................................... 5-27 Figure 5-19 Hoop Stress Prediction from Participant D........................................................... 5-27 Figure 5-20 A Partial Arc Weld Repair..................................................................................... 5-30 Figure 5-21 EWR Mockup........................................................................................................ 5-31
xi LIST OF TABLES Table 2-1 Mockup Fabrication Steps...................................................................................... 2-3 Table 2-2 Model Guidance...................................................................................................... 2-8 Table 4-1 Inputs for Flaw Growth Calculations....................................................................... 4-3 Table 4-2 Symbol Definition for Equation 4-3......................................................................... 4-6 Table 5-1 Benchmark Cases and Their Location in Appendix A........................................... 5-7 Table 5-2 Qualitative Assessment of Prediction Bias............................................................. 5-8 Table 5-3 RMSE for DHD Benchmark.................................................................................... 5-9 Table 5-4 RMSE for Contour Benchmark............................................................................... 5-9 Table 5-5 Time to Through-Wall........................................................................................... 5-19 Table 5-6 Quality Metrics Applied to Phase 2b Axial Isotropic Predictions.......................... 5-23 Table 5-7 Quality Metrics Applied to the Phase 2b Axial Average Hardening Predictions............................................................................................................ 5-24 Table 5-8 Quality Metrics Applied to Phase 2b Hoop Isotropic Predictions......................... 5-25 Table 5-9 Quality Metrics Applied to Phase 2b Hoop Average Hardening Predictions....... 5-28 Table 5-10 Acceptance Measures for Axial Stresses............................................................. 5-29 Table 5-11 Acceptance Measures for Hoop Stresses............................................................ 5-29
xiii EXECUTIVE
SUMMARY
Weld residual stress (WRS) is known to be an important driver of primary water stress corrosion cracking in safety-related nuclear piping. For this reason, it is desirable to formalize finite element modeling procedures for residual stress prediction. The U.S. Nuclear Regulatory Commission (NRC) and the Electric Power Research Institute have conducted joint research programs on residual stress prediction under a memorandum of understanding. These studies have involved modeling and measurement of WRS in various mockups. The latest of these studies, Phase 2b, is discussed in this document.
The Phase 2b mockup was prototypic of a pressurizer surge nozzle dissimilar metal weld, which forms part of the reactor coolant pressure boundary. Two sets of residual stress measurement data were obtained on the Phase 2b mockup: deep hole drilling and contour. Both these methods are strain-relief techniques. In addition to the measurements, 10 independent analysts submitted finite element modeling results of the residual stresses in the mockup. Each participant was provided the same set of modeling guidelines, with the aim of reducing analyst-to-analyst scatter as much as possible. These measurement and modeling data were then used to develop an uncertainty quantification methodology.
The residual stress uncertainty methodology consisted of constructing a statistical model of the data and using bootstrapping methods to calculate relevant 95/95 tolerance bounds and confidence bounds. This methodology improves on past work (e.g., NUREG-2162, Weld Residual Stress Finite Element Analysis Validation: Part IData Development Effort, issued March 2014), which described uncertainty in WRS predictions only in qualitative terms.
Furthermore, the results of the uncertainty quantification effort informed the development of a validation approach of residual stress finite element models.
The uncertainty quantification work provided methods to compare measurements to models, which in turn led to recommendations on hardening law (see Section 5.2). The validation method is a step-by-step procedure for comparing independent finite element modeling results of the Phase 2b mockup to the acceptance measures. If an analyst meets the criteria, then the modeling procedure may be applied with greater confidence to a real case. This procedure is intended as a recommendation rather than a regulatory requirement. It provides a means to demonstrate proficiency in finite element modeling of WRS.
The validation methodology is aimed at 2D axisymmetric WRS predictions for deterministic flaw growth evaluations. The nuclear industry often performs flaw evaluations when seeking alternatives to established inspection and repair/replacement rules. These evaluations require a WRS assumption. If that assumption is based on finite element results, then following the validation procedure offers the industry one method to strengthen its case when seeking NRC approval. This document also investigated how differences in residual stress can affect these flaw evaluations. Important features of the stress profiles include the inner diameter stress, the stress magnitude at the initial flaw depth, and the depths at which the stress profile crosses zero.
Decision-makers can review these aspects of submitted stress profiles as another option for gaining confidence in residual stress predictions.
xv ACKNOWLEDGMENTS The authors would like to thank the following.
John Broussard of Dominion Engineering, Inc., Paul Crooker of the Electric Power Research Institute (EPRI), and Michael Hill of University of California, Davis for technical cooperation in the joint NRC-EPRI research program.
Dusty Brooks, Remy Dingreville, and John Lewis of Sandia National Laboratory for their excellent work on developing an uncertainty quantification scheme for the round robin dataset (see Chapter 3).
The round robin modeling participants for contributing their work to this effort, as described in Chapter 2.
xvii ABBREVIATIONS AND ACRONYMS ASME Code American Society of Mechanical Engineers Boiler and Pressure Vessel Code DHD deep hole drilling EPRI Electric Power Research Institute EWR excavate and weld repair FE finite element fPCA functional principal components analysis ID inner diameter mm millimeter MPa megapascal NDE nondestructive examination NRC U.S. Nuclear Regulatory Commission OD outer diameter PWSCC primary water stress corrosion cracking RMSE root mean square error SIF stress intensity factor WRS weld residual stress i
reference index k
reference index
µk mean at the kth position through the wall thickness k
standard deviation at the kth position through the wall thickness wi weighting factor for the ith WRS profile xi,kWRS stress magnitude of the ith profile at the kth position through the thickness f
a function r
radial position through the wall thickness t
wall thickness of the weld or pipe d
normalized distance through the wall thickness, d = r/t warping function T
operating temperature P
operating pressure time KI mode I stress intensity factor a
half-depth of a flaw
xviii c
half-length of a flaw m
membrane stress b
bending stress cfp crack face pressure stress Gb influence coefficient for global bending Q
flaw shape parameter h(x,a) weight function for the Universal Weight Function Method s(x) stress variation along the crack face da/d flaw growth with respect to time KIth stress intensity factor threshold Qg activation energy Rg ideal gas constant Tabs absolute operating temperature Tref empirical reference temperature tabulated crack growth coefficient tabulated crack growth coefficient K90 SIF at the deepest point along the crack front K0 SIF at the surface point along the crack front g
a function L
number of locations through the wall thickness where a WRS magnitude is known ne number of sampled measurement WRS profiles np number of sampled prediction WRS profiles s
reference index h(d) difference in means function RMSEWRS quality metric on the root mean square error of stress magnitude WRSmean benchmark WRS (the mean of the isotropic predictions from the Phase 2b study)
D1 first derivative of the WRS magnitude with respect to through-wall position h
interval between two positions through the wall thickness diffavg quality metric on the average difference between the prediction WRS and the benchmark value
1-1 1
INTRODUCTION The U.S. Nuclear Regulatory Commission (NRC) and the Electric Power Research Institute (EPRI) initiated a long-term research program on understanding and reducing uncertainty in the numerical prediction of weld residual stress (WRS) in safety-related nuclear components. Part 1 of this report [1] discusses the background and past work of the program in detail (also see [2]).
The through-wall WRS profile is an important input to deterministic flaw growth calculations.
These calculations may form the technical basis for regulatory relief requests to modify repair/replacement or nondestructive examination requirements in nuclear components subject to primary water stress corrosion cracking (PWSCC). Probabilistic fracture mechanics calculations
[3]-[6] rely on well characterized uncertainty for important inputs. For these reasons, it is important to develop sound approaches for reaching best estimates of WRS and the associated uncertainty.
The past research was categorized according to four phases:
(1)
Phase 1: small-scale scientific specimens (2)
Phase 2a: fabricated prototypic pressurizer surge line nozzle (3)
Phase 3: pressurizer surge line nozzles from a canceled plant (4)
Phase 4: optimized weld overlay on a prototypic cold-leg nozzle These four phases consisted of double-blind measurement and modeling studies on the mockups of varying geometry. In general, the work showed that axisymmetric finite element (FE) models provided reasonable estimations of the measurements, but that relatively large analyst-to-analyst uncertainty existed in the predictions. NUREG-2162 [1] lists the following recommendations for future work in the WRS Validation Program:
Develop specific validation criteria for comparing WRS measurement and modeling results.
Establish guidelines for WRS input development for deterministic flaw evaluations, including FE best practices.
Develop additional guidance for accounting for uncertainty in WRS inputs for flaw evaluations.
Focus future FE round robin studies on reducing model-to-model variability, given lessons learned in FE modeling best practices.
Apply more robust methods to quantify modeling uncertainty in future round robin efforts.
The final phase of this research, dubbed Phase 2b, aimed at addressing these issues.
1.1 Phase 2b Effort Phase 2b was a second double-blind round robin measurement and FE modeling study involving a pressurizer surge line nozzle mockup. This mockup was similar to, but not exactly the same as, the Phase 2a mockup discussed in [1]-[2]. Modeling guidelines [7], based on lessons learned from the previous research phases, were developed with the intent of reducing the uncertainty observed in the past work. The measurement program consisted of deep hole drilling (DHD) and the contour methods. Ten international participants submitted independent modeling results.
1-2 The dataset from the Phase 2b study was intended to address the items for future work identified in NUREG-2162. An unbiased view of expected modeling uncertainty is important for developing acceptance measures and WRS input guidelines. These efforts also require more quantitative approaches to describing the data.
1.2 Scope of This Report This report is intended to document the development of a 2D axisymmetric FE validation approach for prediction of WRS for flaw evaluation applications. The validation scheme proposed here draws on the results of the Phase 2b round robin and an uncertainty quantification methodology. Chapter 2 summarizes the Phase 2b round robin study and the resulting dataset.
Chapter 3 discusses the mathematical methods developed to characterize uncertainty in the Phase 2b dataset. Chapter 4 presents the impacts of WRS assumptions on flaw growth calculations. Chapter 5 develops guidelines for WRS inputs for flaw growth calculations and the proposed validation approach. Finally, Chapter 6 contains overall conclusions of the work.
2-1 2
PHASE 2B ROUND ROBIN STUDY 2.1 Purpose The purpose of this effort was to conduct a second FE round robin, similar to the Phase 2a study
[1], [8]-[10], with improved FE modeling guidance. The modeling guidance aimed at reducing analyst-to-analyst scatter. Determining appropriate scatter bands for FE predictions is important for formulating acceptance measures and modeling guidelines. WRS measurements have uncertainties as well. Chapter 3 discusses quantification of both measurement and modeling uncertainties. Both uncertainties must be accounted for when deciding what constitutes an appropriate FE prediction. This chapter discusses the research effort designed to collect the measurement and modeling data. An NRC technical letter report [7] presents more detailed information about the Phase 2b effort.
2.2 Mockup Fabrication The geometry chosen for the Phase 2b round robin study was representative of a pressurizer surge nozzle. Figure 2-1 shows the overall geometry of the mockup.
Figure 2-1 Phase 2b Mockup Geometry (Dimensions in inches [millimeters])
2-2
2-3 Figure 2-2 emphasizes that a backweld was performed on the mockup after ID machining.
Figure 2-2 ID Backweld Table 2-1 provides an overview of the fabrication process. More detailed fabrication information, including welding parameters and bead map drawings, is found in [7].
Table 2-1 Mockup Fabrication Steps Step Description Purpose 1
A36 flange welded to SA182 nozzle Simulates nozzle stiffness in service; not modeled 2
Alloy 82 buttering applied to nozzle Allows for post-weld heat treat of low alloy steel and prepares dissimilar metal weld 3
Post weld heat treatment Tempers martensite in low alloy steel and relieves residual stress 4
Buttered nozzle welded to F316L safe end with Alloy 182 filler metal Simulates shop weld 5
Backchip and reweld Simulates repair weld at inner diameter 6
Safe end welded to TP316 pipe Simulates field closure weld
2-4 2.3 Round Robin Participants Ten participants representing 12 organizations submitted FE results to the round robin study, as represented in Figure 2-3.
Figure 2-3 Participating Organizations These participants represent a cross section of international industry, government, academic, and private contractor organizations. The study was double blind, so the modelers did not have access to the measurement data. Likewise, the measurement practitioners did not have access to the modelers results.
2.4 Weld Residual Stress Measurements Additional background on residual stress measurement is given in Section 2.2 of [1]. VEQTER, Ltd., in Bristol, United Kingdom, and Hill Engineering, LLC, in Rancho Cordova, CA, performed the Phase 2b residual stress measurements. Two sets of measurements were carried out: hole drilling and contour (see Section 2.2.2 of [1]). The DHD and contour methods were chosen over x-ray or neutron diffraction, because they are more reliable in a dissimilar weld. In fact, x-ray and neutron diffraction are known to have larger uncertainties associated with d0 calibration, grain size, texture, and chemical dilution effects present in welds. The hole drilling measurements consisted of a combination of DHD and incremental DHD. Figure 2-4 shows the experimental setup of the hole drilling measurements. Four hole drilling measurements were taken starting at location B shown in Figure 2-4. Location B was located 22° from the weld start location. The other three measurements were made 90° apart from one another (see Figure 2-5). Care was taken to avoid weld start/stop locations around the circumference.
2-5 Figure 2-4 Deep Hole Drilling Measurement Setup Figure 2-5 Hole Drilling Measurements around Circumference The contour measurements involved several cuts, including one cut each for the axial residual stress measurement and the hoop residual stress measurement (see Figure 2-6).
2-6 Figure 2-6 Contour Measurement Setup The final calculation of residual stress accounted for the release of stress at each sectioning operation. The hole drilling measurements were made before the destructive contour measurements. Each of the required cuts was made with the hole drilling measurements in mind, as shown in Figure 2-7.
2-7 Figure 2-7 Cuts to Extract Contour Specimen The section outlined in red in Figure 2-6 is represented by the Cut out section cuts shown in Figure 2-7 (i.e., Cut 3). At each of these cuts, strain gauge measurements are made for the final stress calculation. The cuts represented by the blue, green, and yellow lines in Figure 2-6 were then made. A laser profilometer measured displacements along the relevant cross sections.
2.5 Modeling Guidance The round robin participants were tasked with creating an axisymmetric FE model to predict the residual stress distribution of the Phase 2b mockup. The written problem statement provided to the round robin participants is provided in [7]. Table 2-2 summarizes this guidance, which was based on modeling experience gained in previous work [1], [2], [11].
2-8 Table 2-2 Model Guidance
2-9 2.6 Results This section reports the basic set of results from the Phase 2b FE round robin study. The raw data are reported in both graphs and tables in [7].
2.6.1 Measurement Results Figure 2-8 shows the hole drilling measurement results. In this report, r/t=0 represents the inner surface of the pipe wall, and r/t=1 represents the outer surface of the pipe wall.
Figure 2-8 Hole Drilling Measurement: (a) Axial, (b) Hoop Figure 2-9 and Figure 2-10, respectively, show the hoop and axial stress measurements for the contour method.
Figure 2-9 Hoop StressContour Measurement
2-10 Figure 2-10 Axial StressContour Measurement The DHD and contour datasets are, by nature, different. The DHD data are a one-dimensional profile of the stress variation along a straight path through the weld centerline. In contrast, the contour method gives a two-dimensional representation of the stress variation on an entire cross section. As described in Table 2-2, the modeling data were collected as one-dimensional path data extracted from the FE results along the centerline of the weld, so as to be compared with the DHD data. Therefore, the contour data must be processed to extract appropriate path data to compare to the modeling data. The extracted contour data should be a one-dimensional stress profile and represent the stress along a straight path through the weld centerline, normal to the inside surface.
2.6.2 Modeling Results Figure 2-11 shows an example mesh from one of the FE round robin participants.
2-11 Figure 2-11 Example Mesh The red line in Figure 2-11 represents the path along which the participant extracted the data (i.e.,
the weld centerline). The figure also illustrates major geometry features modeled by the participants. Figure 2-12 and Figure 2-13 show the isotropic and nonlinear kinematic hardening results of the Phase 2b round robin study, respectively. A qualitative look at the modeling results reveals the following observations:
- Individual predictions may potentially be considered outliers (e.g., participant J), when compared to the rest of the sample.
- Nonlinear kinematic and isotropic results show different through-wall trends.
- The nonlinear kinematic results show smaller stress magnitudes than the isotropic results.
- The nonlinear kinematic results generally exhibit less scatter than the isotropic results.
2-12 Figure 2-12 Processed Isotropic Hardening Results: (a) Axial, (b) Hoop Figure 2-13 Processed Nonlinear Kinematic Hardening Results: (a) Axial, (b) Hoop 2.6.3 Discussion Comparison of the measurement and modeling data requires careful thought. Both the modeling data and the measurement data exhibit uncertainties. Chapter 3 of this document focuses on quantitatively evaluating both modeling and measurement uncertainty. The end goal is to develop a procedure to objectively judge FE models of WRS, as discussed in Chapter 5.
One final technical topic to be resolved is the choice of hardening law. When providing guidance on hardening law, it is important to avoid biases in the model prediction in addition to minimizing prediction errors. One simplified approach suggested elsewhere [12] involves use of the average of the nonlinear kinematic and isotropic predictions. Section 5.2 discusses the choice of hardening law.
2.7 Conclusions This chapter summarizes the Phase 2b round robin study. The WRS modeling and measurement results from this study constitute the dataset analyzed in the uncertainty analysis in Chapter 3.
Ten analysts participated in the modeling portion of the round robin, resulting in 10 isotropic and 10 nonlinear kinematic WRS predictions for both axial and hoop stresses. Two measurement
2-13 vendors performed strain relief-based WRS measurements on the mockup. This resulted in four DHD measurements of axial and hoop stresses along the weld centerline. The contour measurement resulted in a two-dimensional representation of the WRS along a given cross section. This dataset, viewed in the context of the Chapter 3 analysis, will be used to develop the guidelines and validation scheme presented in Chapter 5.
3-1 3
UNCERTAINTY QUANTIFICATION METHODOLOGY 3.1 Motivation In [1], the NRC documented the need to apply more sophisticated data analysis techniques to residual stress measurement and modeling data. At that stage, only qualitative judgments were applied to describe modeling uncertainty and measurement-to-model comparisons. To define an objective validation process for WRS predictions, it is necessary to use a quantitative analysis.
The quantitative analysis described in this section of the NUREG does not need to be repeated by analysts trying to use the WRS prediction validation scheme presented in this report.
Previous work in this area includes the development of a sampling scheme for WRS in a probabilistic fracture mechanics code [5]-[6]. The baseline dataset was four FE WRS profiles obtained by different analysts for a given weld configuration. Estimates of skewness and kurtosis were used to assign an appropriate uncertainty distribution type for the WRS FE data at each point through the pipe thickness. In determining the final estimates for the mean WRS and standard deviation, the analysts introduced a weighting approach that decreased the importance of a particular WRS prediction the further away it was from the other predictions. This is represented mathematically as:
=
=
=
n i
i n
i WRS k
i i
k w
x w
1 1
µ and Equation 3-1
(
)
=
=
=
n i
i n
i k
WRS k
i i
k w
x w
1 1
2
µ
where µk and k are the mean and standard deviation of the distribution at the kth position through the weld thickness, respectively; wi is the weight for the ith WRS profile based on the differences in stress predictions between two WRS profiles; and xi,k is the value of the stress prediction for the ith profile at the kth position through the wall thickness. With the uncertainty in WRS thus defined, Kurth et al. [5]-[6] conceived a sampling strategy that accounted for point-to-point smoothness and static equilibrium requirements. In this way, the probabilistic fracture mechanics analysis may account for the uncertainty in the WRS profile for a given weld configuration.
The approach presented here is aimed at deterministic fitness-for-service calculations, where a residual stress assumption is required (see Chapter 4). This approach involves a range of mathematical tools aimed at defining uncertainty bands on the round robin measurement and modeling results. The results then form the basis for recommended modeling practices and model validation approaches. The methodology described here is documented in greater detail in
[13], and Section 3.2 provides only a summary.
3-2 3.2 Methodology 3.2.1 Functional Data The round robin WRS modeling and measurement dataset is discrete by nature. Even the contour measurement is based on a finite number of measurements along the surface of the part.
It is also functional data, in that the WRS magnitude for a given stress component, WRS, depends on the spatial location along the pipe cross section, as:
( )
d f
WRS =
Equation 3-2 where d=r/t is the normalized distance from the inside surface to the outside surface of the weld.
References [15] and [16] point out that it is useful to consider such data as a continuous function.
They introduce the mathematical methods that can be applied to functional data. This section describes a statistical model constructed to represent the round robin dataset, based on the methods of [15] and [16]. This approach enables bootstrapping to estimate confidence bounds and tolerance bounds on both the measurement and modeling data [17]-[18]. The final outcome of the work is an objective process for validating WRS FE modeling (see Chapter 5).
3.2.2 Screening of Outlier Predictions As described in Chapter 2, the idea behind the Phase 2b round robin study was to assess the prediction uncertainty of a group of analysts modeling the same problem under a given set of guidelines. The 10 submissions were screened for potential outlying results that may not have been obtained in strict accordance with the modeling guidance. Tran et al. [19] described two outlier predictions in the round robin dataset and the reasons behind them. One participant used incorrect material property data, and the other incorrectly modeled the heat input of the stainless steel closure weld. A third outlier involving incorrect weld thickness was identified in [13]. These three predictions were screened out for the purposes of uncertainty quantification. As discussed in Section 3.3.1, one other prediction was removed from the hoop stress profiles because of the undue influence it had on the bootstrap tolerance bound results.
3.2.3 Data Smoothing The WRS measurements were reported at discrete spatial locations. Similarly, the round robin modeling participants provided stress magnitudes at discrete depths through the wall thickness.
The actual WRS distribution is expected to be a continuous function of spatial location. Data smoothing was applied here to arrive at a smooth, continuous representation of the WRS profile.
The smoothing was accomplished via cubic splines, which are a series of third degree polynomials connected together at a given number of nodes [20]. The optimal number of nodes to achieve an acceptable fit was determined by an algorithm discussed in [13]. As an example, the axial stress predictions assuming isotropic hardening are shown after smoothing in Figure 3-1 (compare with Figure 2-12a; outliers removed).
3-3 Figure 3-1 Axial Isotropic Data after Smoothing 3.2.4 Amplitude and Phase Variability Functional data can exhibit two types of variability: amplitude and phase variability. Considering a sinusoidal function, the amplitude variability is the result of differences in peak height of two curves, and phase variability is the result of a horizontal shift of one curve relative to the other (see Figure 3-2).
Figure 3-2 Amplitude and Phase Variability Both types of uncertainty are present in the round robin dataset, as shown in Figure 3-1. For the case of WRS, amplitude variability is equivalent to variability in stress magnitude at corresponding local extrema. Phase variability has a spatial context (e.g., how the depth at the local maximum differs among various predictions). The methodology proposed in this section accounts for these two types of variability.
3-4 3.2.5 Modeling Amplitude and Phase Variability Registration is the process of aligning the data horizontally and thus removing phase variability.
Specifically, this process aligns the local extrema. Registration is accomplished through the use of warping functions, [13]. Warping functions are chosen such that the boundaries of the original functions are preserved. For the case of WRS, this means that the inner diameter (ID) and outer diameter (OD) stresses of the smoothed data are retained in the transformed functions.
The other requirement for warping functions is that both and 1
are differentiable, so that the transformed function is smooth and can be mapped back to the original function [13]. Removing the phase variability via the warping functions allows characterization of the amplitude variability.
The warping functions themselves provide a useful characterization of the phase variability.
Figure 3-3 Axial Isotropic Data after Alignment Functional principal components analysis (fPCA) is a dimension reduction technique to model the dominant modes of variation in the aligned data. The mathematical details and fundamental concepts of fPCA are better described elsewhere [13]-[16]. fPCA was applied to both the registered data and the warping functions to construct a statistical model of the residual stress data. The model allows for statistical sampling. Figure 3-4 shows 100 sampled profiles from the model constructed from the seven isotropic hardening axial stress predictions. The black curves in Figure 3-4 are the smoothed WRS predictions from the Phase 2b study. The modeled profiles demonstrate amplitude and phase variability similar to those of the original sample.
3-5 Figure 3-4 100 Sampled WRS Curves Based upon Round Robin Modeling Data 3.2.6 Bootstrapping Bootstrapping is a statistical sampling technique that provides a method to estimate uncertainty in distribution parameters, such as the mean. Further details of bootstrapping are described in [13]-
[16]. This technique is applied here, along with the model described in Sections 3.2.1-3.2.5, to determine confidence bounds and tolerance bounds related to the Phase 2b round robin dataset, with mathematical details provided in [13]. The results are applied in Chapter 5 to draw conclusions about modeling recommendations and to inform development of a validation procedure for FE prediction of WRS.
3.2.7 Uncertainty Characterization of the Measurement Data The statistical model summarized in Sections 3.2.1-3.2.5, while presented in the context of the modeling data, can also be applied to the measurement data. The DHD data consisted of four measurements around the circumference of the mockup, 90° apart from one another. The statistical model for bootstrapping was constructed from the four measured stress profiles.
Figure 3-5 shows the axial contour data again. As the figure suggests, many one-dimensional stress profiles through the weld centerline can be extracted from the axial contour dataset.
Because of this unique feature of the axial contour data, it was not necessary to construct a statistical model or to perform bootstrapping.
3-6 Figure 3-5 Contour Axial Stress Data 3.2.8 Tolerance Bounds versus Confidence Bounds Bootstrapping was employed to construct both tolerance bounds and confidence bounds related to the round robin dataset. A more rigorous treatment of these statistical bounds is found elsewhere [21]. For the purposes of this document, a high-level definition of the statistical bounds determined in this work will suffice. Confidence bounds provide intervals within which a particular statistic is expected to lie. For instance, the confidence bounds on the mean prediction indicate the interval within which the true mean lies, with 95 % statistical confidence. Figure 3-6 gives examples of bootstrapped confidence bounds on the mean. Confidence bounds can be constructed on other statistics, such as quantiles.
Tolerance bounds are intervals within which 95 % of the residual stress data (either measurement or prediction) are expected to lie. The upper tolerance bound is constructed using the upper confidence bound on the 0.975 quantile. The lower tolerance bound is constructed using the lower confidence bound on the 0.025 quantile. The choice of the 0.975 and 0.025 quantiles leads to a coverage level of 95 %. Figure 3-7 shows examples of bootstrapped tolerance bounds.
3.3 Results This section presents example results that illustrate the outcomes of the methods described in Section 3.2. Comprehensive results are presented in [13].
3.3.1 Uncertainty Quantification for the Prediction Data Figure 3-6(a) shows bootstrap sample means compared against the smoothed axial stress FE prediction data for isotropic hardening. These results lead to 95 % confidence bounds on the prediction mean for these data, which are shown in Figure 3-6(b). Figure 3-7 shows similar plots for constructing the 95/95 tolerance bounds.
3-7 Figure 3-6 Constructing Confidence Bounds on the Mean (Axial, Isotropic Case): (a) 30 of the 1,000 Bootstrap Sample Means and (b) Resulting Confidence Bounds
3-8 Figure 3-7 Constructing Tolerance Bounds (Axial, Isotropic Case): (a) 30 of the 1,000 Bootstrap 2.5th and 97.5th Quantiles and (b) Resulting Tolerance Bounds
3-9 As introduced in Section 3.2.2, the analysis of the seven isotropic hoop stress predictions that passed the initial screening revealed that one prediction was strongly influencing the upper tolerance bound results. Figure 3-8 shows the potential outlier and demonstrates the significant impact it has on the 95/95 tolerance bounds. Specifically, the potential outlier suggests a roughly constant hoop stress prediction through the thickness. Since a majority of this dataset, including measurements (see Figure 2-8 and Figure 2-9) and modeling results, indicates some variation of hoop stress through the weld thickness, it may be appropriate to screen out this potential outlier when determining tolerance bounds for validation purposes.
3-10 Figure 3-8 Bootstrap Tolerance Bounds on Isotropic Hoop Stress Predictions: (a) With Potential Outlier and (b) Without Potential Outlier
3-11 3.3.2 Uncertainty Quantification for the Deep Hole Drilling Measurement Data Figure 3-9 demonstrates the data smoothing process for axial DHD data. It shows that the smoothing residuals increase beyond a normalized depth of 0.6. This is because the measurement data were obtained at relatively coarse spatial increments near the OD. This data fitting issue may lead to less confidence in the bootstrap quantities determined for all DHD data beyond r/t=0.6.
3-12 Figure 3-9 Data Smoothing for Axial DHD Data: (a) Raw Data, (b) Smoothed Data, and (c)
Residuals
3-13 Figure 3-10 and Figure 3-11 show the bootstrap confidence bounds and tolerance bounds for the DHD axial stress measurement data, respectively.
Figure 3-10 Confidence Bounds on the Mean (Axial DHD Data)
Figure 3-11 Tolerance Bounds (Axial DHD Data)
3-14 Figure 3-12 and Figure 3-13 show the bootstrap confidence bounds and tolerance bounds for the DHD hoop stress measurement data, respectively.
Figure 3-12 Confidence Bounds on Mean (Hoop DHD Data)
Figure 3-13 Tolerance Bounds (Hoop DHD Data)
3-15 3.3.3 Uncertainty Quantification for the Contour Measurement Data As mentioned in Section 3.2.7, the axial stress contour data did not require construction of a statistical model and bootstrapping to quantify the uncertainty in the data. The cross section shown in Figure 3-5 is located entirely along the dissimilar metal weld centerline (also see the illustration in Figure 2-6). This centerline data can be used to directly compare to the prediction stress profiles by extracting path data, as illustrated in Figure 3-5. The linear paths defined for data extraction should be perpendicular to the boundaries of the data. Figure 3-14 shows example stress profiles extracted from the contour data, along with the profiles provided by the measurement vendor.
Figure 3-14 50 Extracted Stress Profiles While Figure 3-14 shows 50 example stress profiles, the analysis procedure used 500 extracted profiles in order to have adequate statistics to determine confidence bounds and tolerance bounds. Repeating the analysis with 5,000 profiles did not change the results. Figure 3-15 compares the tolerance bounds based on two different methods. One method is based on the five stress profiles provided by the contour measurement vendor. The other method is based on extracting 500 stress profiles without modeling and bootstrapping. Figure 3-15 shows that using the extracted 500 stress profiles leads to tighter tolerance bounds.
3-16 Figure 3-15 Tolerance Bounds for Axial Contour Data 3.4 Conclusions This chapter presented a methodology for quantifying uncertainty in the round robin WRS dataset.
A statistical model was constructed for the modeling data and the DHD measurement data. The statistical model enabled bootstrap estimates of confidence bounds and tolerance bounds. For the axial contour measurement data, it was not necessary to employ bootstrap techniques.
Instead, 500 curvilinear stress profiles were extracted from the contour measurements. Use of these profiles allowed direct determination of the mean and tolerance bounds. This method improves on the previous work [1], where uncertainty was described only in subjective terms. The results of this analysis will help inform the development of a validation process in Chapter 5.
4-1 4
WRS IMPACT ON FLAW GROWTH CALCULATIONS 4.1 Regulatory Application NRC regulations require owners of nuclear power plants to periodically perform nondestructive examinations of safety-related piping according to the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code),Section XI [22], and ASME Code Case N-770
[23]. If the exam discovers an indication, then the geometry of the potential flaw is compared to the acceptance standards of Section XI, IWB-3500. If the flaw is not allowable, then the licensee must either repair or replace the piping or perform an analytical evaluation according to IWB-3600 for temporary acceptance of the flaw. Connected flaws on the inner surface are generally not allowed in service because of PWSCC [22]. The NRC has granted short-term regulatory relief to licensees, usually in cases where inservice inspection requirements present a demonstrated hardship to the plant owner (see [24] as one example). Figure 4-1 summarizes this process.
Figure 4-1 ASME Code Flaw Disposition Procedure An analytical evaluation per ASME Code,Section XI, IWB-3600, involves an engineering estimate of the growth of the flaw within an established timeframe. ASME Code,Section XI, Nonmandatory Appendix C, provides guidance and equations for many aspects of a flaw evaluation in piping, including the following:
4-2 pipe stress acceptance measures screening for failure mode flaw stability crack growth rate laws [25]
Nonmandatory Appendix A of Section XI, paragraph A-3000, contains stress intensity factor (SIF) solutions that may be applied to piping. Figure 4-2 outlines the basic procedure of a flaw growth evaluation.
Figure 4-2 Analytical Flaw Evaluation Procedure As Figure 4-2 shows, the analytical evaluation requires an assumption about WRS. In many licensee submittals, an FE model serves as the basis behind the assumed WRS. The focus of this chapter is to examine how the WRS input affects the flaw growth calculation.
4-3 4.2 Inputs This work draws on a series of flaw growth calculations documented in the technical letter report on the Phase 2b study [7]. Table 4-1 shows the inputs for this work.
Table 4-1 Inputs for Flaw Growth Calculations OD - outer diameter t - pipe wall thickness a0 - initial flaw depth 2c0 - initial flaw length T - operating temperature p - operating pressure m - operating membrane stress b - operating bending stress The dimensions in Table 4-1 are consistent with the Phase 2b mockup geometry given in Chapter
- 2. This chapter will examine the case of a circumferential flaw subjected to the WRS profiles determined by the axial WRS measurements in the Phase 2b study, as shown in Figure 2-8a and Figure 2-10.
4.3 Superposition of Stresses Figure 4-3 shows the residual stress profiles, with m and cfp (the crack face pressure stress) overlayed on the figure. A representative contour measurement of axial residual stress is also included on the figure.
Figure 4-3 Loads from Various Sources OD [mm]
t [mm]
Weld Width [mm]
a 0 [mm]
2c 0 [mm]
T [oC]
p [MPa]
m [MPa] b [MPa]
381 36.07 26.48 3.607 7.214 315.6 15.5 60 100
4-4 In the method applied here, m, cfp, and WRS were superimposed for the purpose of calculating the SIF. Figure 4-4 shows the results of this superposition, along with annotations of salient features of the curves.
The ID stresses (i.e., at r/t=0) were compressive for each curve, with the contour measurement being the most compressive at -166 MPa. The stress at the initial crack depth (i.e., r/t=0.1) was tensile for the DHD curves and compressive for the contour measurement. The highest stress at r/t=0.1 was observed in the 112° curve at 18 MPa.
Three of the four DHD curves crossed zero for the second time at r/t=0.32, with very little spread.
The 292° curve deviated from this trend by crossing zero at r/t = 0.37. The local maximum around r/t=0.2 for the 292° curve, however, was less than that of the other three DHD curves. The DHD curves crossed zero a third time at roughly r/t=0.64, although there was noticeable spread about this value. Finally, the contour curve crossed zero only one time, beyond the mid-thickness of the pipe and just ahead of the DHD curves.
Figure 4-4 Superposition of Membrane, Crack-Face Pressure, and Weld Residual Stresses 4.4 Stress Intensity Factor and Crack Growth The total SIF was the sum of that stemming from global bending stress and that stemming from the remaining stresses (i.e., m, cfp, and WRS). The SIF for b was calculated with influence coefficients for global bending [26], according to Equation 4-1.
Q a
G K
b b
I
=
Equation 4-1
4-5 where Gb is the influence coefficient and Q is the flaw shape parameter. In this case, b was considered to be the maximum bending stress occurring at the top dead-center location of the pipe as a result of the applied bending moment.
The SIF for the remaining stresses was determined with the Universal Weight Function Method
[27]-[28]. The superimposed stress profiles shown in Figure 4-4 were input into the calculation as discrete arrays. As such, there was no need for a polynomial fit of the stress profile, as is sometimes the practice. The basic form for this SIF solution is shown in Equation 4-2.
(
) ( )
=
a I
dx x
a x
h K
0
Equation 4-2 where h(x,a) is the weight function. In this work the SIF was calculated at both the deepest point (K90) and the surface point (K0) of the flaw, as shown in Figure 4-5.
Figure 4-5 SIF at Two Locations along Crack Front SIF calculations are necessary to use the established crack growth law, which is based on laboratory crack growth experiments on compact tension fracture mechanics specimens [25]. The equation describing the crack growth rate is given in Equation 4-3.
(
)
Ith I
ref abs g
g K
K T
T R
Q d
da
=
1 1
exp Equation 4-3 Table 4-2 defines the symbols in Equation 4-3.
4-6 Table 4-2 Symbol Definition for Equation 4-3 4.5 Flaw Growth Results Figure 4-6 shows K90 and a/t versus time for the flaw growth calculation. No growth resulted from the calculation based on the contour measurement. The DHD SIF curves exhibited similar trends of increasing to a peak early in time and subsequently decreasing to a plateau. The 112° and 292° curves showed a rapid increase in SIF later in time. Correspondingly, the 112° and 292° curves showed through-wall crack growth, while the 22° and 202° curves demonstrated crack arrest for the time period analyzed. However, a typical relief request submitted to the NRC is only concerned with timeframes of less than 20 years or 240 months, as discussed further in Section 4.6.
The 112° curve started at the highest K90 value and peaked the earliest in time at about 100 months and 14 MPam. It plateaued at a value of roughly 3.5 MPam, which was noticeably higher than the other three curves. After 400 months, the SIF steadily increased, followed by a rapid increase at 480 months. The flaw growth in the depth direction responded to the trends in SIF just described. Hence, when the SIF plateaued at 3.5 MPam, the flaw grew linearly in time.
The other three DHD curves exhibited similar trends, but with a few differences. The peak in SIF was shifted to later times relative to the 112° measurement. This peak was also of a slightly lower magnitude, but still in the range of 12-13 MPam. The 22° and 202° curves did not exhibit the sharp increase in SIF in the time period analyzed here.
4-7 Figure 4-6 (a) K90 and (b) Growth in Depth Direction Figure 4-7 shows K0 and 2c/C, where C is the inner circumference of the pipe, versus time for the analytical flaw evaluation. The SIF value was highest for the 112° measurement, followed by 292°, 202°, and 22°. The crack length grew relatively slowly during the first 100 months for the 112° measurement. After this time, the length steadily grew to 6 % of the circumference. The other curves exhibited similar trends but did not grow to the same extent.
4-8 Figure 4-7 (a) K0 and (b) growth in length direction 4.6 Discussion Figure 4-6 shows the apparent uncertainty in flaw growth calculations resulting from the residual stress assumption. However, regulatory relief submittals to the NRC do not evaluate 720 months of operation. In fact, evaluation periods may extend only one or two refueling outages (1.5 to 3 years). Figure 4-8 shows that the uncertainty in the results decreases for shorter evaluation periods.
4-9 Figure 4-8 Flaw Growth after 20 Years However, it is still useful to examine the reasons behind the apparent sensitivity to residual stress assumption evident in Figure 4-6. As Figure 4-4 shows, the 112° case remained within 50 MPa of the other DHD measurements for the first 30 % of the wall thickness. Even so, the calculated flaw growth roughly doubled the others with a/t=0.3 at 100 months for the 112° curve. Only the 112° and 292° cases showed through-wall crack growth. The 292° residual stress led to through-wall growth despite peaking below 100 MPa at r/t=0.2, which is in stark contrast to the remaining curves. This section will seek to explain how features of the assumed residual stress profile may affect the calculated flaw growth behavior.
The SIF for membrane and residual stresses is given by the integral shown in Equation 4-2. As a first approximation, this integral is similar to the area under the curves of Figure 4-4. Figure 4-9 shows the area under these curves as calculated by the trapezoidal rule.
4-10 Figure 4-9 (a) Membrane Stresses, (b) Area under the Curve The area under the curve in Figure 4-9(b) reveals greater contrasts among the various measurements than the stress profiles in Figure 4-9(a). The area under the 112° curve remains clearly highest until about half way through the wall thickness, where the 292° curve becomes slightly dominant. The 292° curve, despite peaking at a lower stress magnitude than the other measurements, remains tensile for the greatest depth. This fact keeps the SIF high enough through the calculation to allow for through-wall growth by 720 months. Once the crack tip reaches the compressive zone (e.g., r/t=0.32), the 22° and 202° measurements show a steeper drop in both stress magnitude and area under the curve. This leads to crack arrest in these two cases.
4-11 4.7 Conclusion This chapter confirms previous work showing that flaw growth calculations are sensitive to the residual stress input [29]. Features of the residual stress curves that affected the results included the following:
the ID stress magnitude the stress magnitude at initial flaw depth the location through the wall thickness where the compressive zone started the slope of the curve in the compressive zone While Chapter 5 presents a validation methodology for WRS FE models, this chapter demonstrates that simplified approaches for judging the adequacy of residual stress inputs may also be applied. Where confirmatory analyses of residual stress predictions are practical, the listed features can be compared and contrasted to provide confidence in assumed inputs.
Estimating the area under the curve may also provide additional insights. While current approaches to flaw evaluation appear to be adequate, a validation methodology for WRS FE models may ease regulatory uncertainty and review times for relief requests.
5-1 5
VALIDATION PROCEDURE AND FINITE ELEMENT GUIDELINES 5.1 Introduction This chapter draws on the uncertainty quantification methodology described in Chapter 3 to develop a validation procedure for FE predictions of WRS. Accompanying the validation procedure are guidelines for creating FE models of WRS. Together, the validation method and guidelines may increase confidence in WRS inputs in relief requests.
The procedure proposed here involves two aspects: (1) establishing and justifying modeling guidelines (Sections 5.2 and 5.3) and (2) proposing a series of quality metrics an analyst can calculate to objectively assess the quality of an individual FE prediction of WRS (Section 5.4).
The discussion in Sections 5.2 and 5.3 assesses the Phase 2b dataset as a whole, while Section 5.4 focuses on a particular analyst seeking to validate an FE methodology.
The approach presented here requires an individual analyst to construct an FE model of the Phase 2b mockup, according to the guidelines given in [7]. A series of quality metrics and acceptance measures are proposed to validate the analysts prediction. Since this process is aimed at deterministic fitness-for-service calculations (see Chapter 4), the metrics were designed to ensure acceptable predictions of flaw growth.
The Phase 2b dataset is directly applicable to axisymmetric (i.e., two-dimensional) models of dissimilar metal butt weld geometry. Extending this procedure to other geometries may require additional work, such as fabrication of a mockup and measurement of residual stress. Section 5.6 discusses further the validation of residual stress predictions in other applications.
5.2 Material Hardening Law One topic identified in earlier work was the need to establish guidance on hardening law choice because of the significant impact this assumption has on the FE results [1]. This section describes measurement-model comparisons with the goal of making informed judgments about the appropriate approach to modeling material hardening during thermal cycling that occurs during welding operations. This section first describes a methodology to account for modeling and measurement uncertainty when making measurement-model comparisons, as developed in [13].
Sections 5.2.3 and 5.2.4 compare and contrast three approaches (isotropic, nonlinear kinematic, and the average of isotropic and kinematic) to hardening law.
5.2.1 Difference in Means and Root Mean Square Error Functions One method used here to investigate the performance of various hardening law approaches is to examine the difference in means between the predictions and the measurements in the Phase 2b dataset. The methodology, described in [13], is summarized as follows.
- 1. Sample ne measurement WRS functions and np prediction WRS functions from the model described in Chapter 3 on a fine grid of L values of d, where d is the normalized distance through the pipe wall thickness. This results in samples of WRS functions from both measurements and predictions representing uncertainty in both. Let f be a function representing sampled measurement WRS profiles and g be a function representing sampled prediction WRS profiles, as follows.
5-2
(
)
k i d f
, k = 1,2,,L and i = 1,2,,ne
(
)
k i d g
, k = 1,2,,L and i = 1,2,,np where i represents the th sample. The two functions are sampled independently.
- 2. Compute
(
)
(
)
(
)
(
)
k s
s s
s d
h d
h d
h h
2 1
=
where
(
)
(
)
(
)
=
=
=
e p
n i
n i
k i
p k
i e
k s
d g
n d
f n
d h
1 1
1 1
Equation 5-1 The subscript s represents the sth difference in means calculation.
- 3. As a measure of prediction quality, calculate the root mean square error (RMSE) of hs, which is defined as
(
)
=
=
L k
k s
d h
L RMSE 1
2 1
Equation 5-2
- 4. Repeat steps 1, 2, and 3 S times. In this study, S = 1,000.
- 5. Compute the pointwise 0.975 and 0.025 quantiles of hs(dk) and RMSE over the S samples for each k. These quantiles form a pointwise 95 % bootstrap confidence bound for the population difference of means function and the RMSE.
This methodology allows consideration of both measurement and modeling uncertainty when assessing the quality of predictions.
5.2.2 Assessment of Prediction Trends WRS predictions should capture variations in stress magnitude with spatial position. Within the context of the procedure outlined in Section 5.2.1, this means that the estimated confidence bounds on the mean difference function, hs(dk), should encompass zero. If the confidence bounds on the mean difference function do not encompass zero, this implies a prediction bias. Figure 5-1 shows how well the nonlinear kinematic hardening FE results for axial stress predict the DHD measurements. Figure 5-1 clearly illustrates where the nonlinear kinematic predictions systematically over-and under-predict the DHD data in a statistically significant manner. In Figure 5-1(b), a positive mean difference implies an underprediction of the measurements.
5-3 Figure 5-1 Nonlinear Kinematic Hardening Predictions against the DHD Measurements:
(a) Actual Data and (b) Mean Difference Function and Tolerance Bounds
5-4 Figure 5-2 and Figure 5-3 show similar figures for isotropic hardening and average hardening, respectively. Overall, the mean difference functions for these two cases remain closer to zero throughout the wall thickness than was observed for the nonlinear kinematic predictions. There are locations through the wall thickness where the tolerance bounds do not encompass zero, indicating certain trends that are not captured by the FE. In Figure 5-2(b) and Figure 5-3(b), for instance, the isotropic and average hardening results consistently underpredict the DHD measurements around r/t=0.75. A result such as that in Figure 5-2(b), while not perfect, indicates that the predictions are reasonable in a qualitative sense.
5-5 Figure 5-2 Isotropic Hardening Predictions against the DHD Measurements: (a) Actual Data and (b) Mean Difference Function and Tolerance Bounds
5-6 Figure 5-3 Average Hardening Predictions against the DHD Measurements: (a) Actual Data and (b) Mean Difference Function and Tolerance Bounds Appendix A shows other plots similar to Figure 5-1, Figure 5-2, and Figure 5-3 for all. Table 5-1 lists all the relevant cases and the corresponding location of the data plots.
5-7 Table 5-1 Benchmark Cases and Their Location in Appendix A Table 5-2 contains a qualitative description of the prediction quality for each of the cases in Table 5-1 along with a description of where measurement trends are not well captured by the model predictions. The mean RMSE is included in Table 5-2 for a quantitative point of reference. Table 5-2 indicates that RMSE alone may not be an adequate indicator of prediction quality. For case 3 (axial stress, average hardening, DHD benchmark) RSME=48.14 MPa, which is a relatively low value for this dataset. However, the average hardening approach consistently underpredicted the DHD measurements at r/t=0.25 and 0.75 for this case. In contrast, case 5 (hoop stress, isotropic hardening, DHD benchmark) had a relatively high RSME but no evident prediction bias. In other words, the confidence bounds encompassed zero throughout the entire thickness for case 5 (Figure A-5). Case 9 (axial stress, average hardening, contour benchmark) is perhaps the best agreement between measurements and models obtained in this study. Figure A-9 shows that, where systematic prediction biases existed, the tolerance bounds were very close to encompassing zero. This case also had the lowest mean RMSE (36.77 MPa). Overall, this work (and past work [1]-[2]) demonstrates that FE provides reasonable predictions of residual stress.
Although, it is evident that established guidelines on hardening law approach are needed.
5-8 Table 5-2 Qualitative Assessment of Prediction Bias 5.2.3 Assessment of Root Mean Square Error RMSE (Equation 5-2) may be one potential indicator of prediction quality. This value provides a general measure of how well stress magnitudes are predicted. Table 5-3 and Table 5-4 show RMSE for the various comparison cases for the DHD benchmark and the contour benchmark, respectively.
5-9 Table 5-3 RMSE for DHD Benchmark Table 5-4 RMSE for Contour Benchmark Figure 5-4 and Figure 5-5 show these values plotted as bar charts, including the appropriate confidence bounds, for the axial stress predictions and the hoop stress predictions, respectively.
In most cases, the models that used the nonlinear kinematic assumption demonstrated the highest RSME. For the axial stress predictions with contour benchmark [Figure 5-4(b)], the nonlinear kinematic and isotropic models were indistinguishable. This is also the only case where the average hardening approach showed clearly superior predictions than the isotropic models. In all other cases, the apparent improvement in prediction agreement of average over isotropic was within the confidence bounds on RMSE.
Figure 5-4 Root Mean Square Error for Axial Stress Predictions: (a) DHD Benchmark and (b) Contour Benchmark
5-10 Figure 5-5 Root Mean Square Error for Hoop Stress Predictions: (a) DHD Benchmark and (b) Contour Benchmark 5.2.4 Hardening Law Recommendation This study investigated three hardening law approaches: nonlinear kinematic, isotropic, and the average of the kinematic result and isotropic result. Two aspects that should be assessed when evaluating different hardening law approaches are prediction bias and RMSE. Table 5-2 indicates that the through-wall trends were predicted well for three cases: 2, 5, and 9. Overall, the analysis in this section indicates that the nonlinear kinematic hardening models were the least accurate.
While the uncertainties were large, there was some indication that the averaging approach provides better predictions than isotropic. Given these considerations, the authors recommend use of the averaging approach. Based on this study, the NRC considers that the mean of the average models is validated against the measured data, and therefore it is acceptable to validate further models against the mean of the average models.
This study did not consider the Lemaitre-Chaboche hardening law, also known as mixed hardening [34]. Real materials exhibit both isotropic and kinematic hardening characteristics. The experimental material data needed to develop a mixed hardening law were not available at the time the Phase 2b round robin was began. In the future, it may be valuable to repeat a round robin modeling study with mixed hardening to investigate how well this hardening law compares with the measurement data presented here. The same statistical methods should be applied to account for both modeling and measurement uncertainty and develop tolerance bounds on the mean difference function.
5.3 Modeling Guidelines While hardening law may be the most important factor, guidelines regarding other modeler choices have been developed through industry experience [11] and through the round robin studies [1]. These guidelines were provided to the Phase 2b modelers as instructions to participate in the round robin analysis effort, as described in [7]. As indicated by the comparisons of measurements and models in Section 5.2.2 and Appendix A, there is a general, qualitative sense that the FE predictions of residual stress from the Phase 2b study are reasonable (e.g., see Figure A-5 and Figure A-9). Thus, the modeling guidelines of [11] are adopted here. The recommendations for axisymmetric models are shown in the following list.
5-11 Weld Bead Geometry Definition o Modeling the precise bead shape is unnecessary.
o Weld beads may be approximated as trapezoids.
o The total number of weld beads, the number of weld layers, and the number of beads in each layer should approximate the real weld configuration as closely as possible.
o Given current computational capabilities, modeling a realistic number of weld passes in an axisymmetric model is feasible. Approximations resulting from pass-lumping should be avoided.
o Where fabrication records are lacking, the assumed weld configuration should be based on common industry practice and knowledge of the component (e.g., nominal wall thickness).
o The cross-sectional area of each weld bead should be approximately equal to aid in heat input tuning.
Bead and Process Sequence o Residual stress FE models are path-dependent. The analyst should model the actual fabrication process as closely as possible, including bead sequencing, number and size of weld beads, and other relevant processes (e.g., repairs and PWSCC mitigation).
o The analyst should explicitly model the application of the butter and associated postweld heat treatment.
Element birth and death methodology for welding process modeling o Several different methodologies may be acceptable to model the addition of material as the weld is deposited.
o One method consists of removing the weld elements at the beginning of the simulation, and then adding one weld pass at a time in a stress-free configuration but with active temperature dependent material properties, heating it and cooling it, and so on.
o Another method consists of having the elements present at all times in the model, but only activation their temperature dependent material properties once a pre-determined temperature is reached (perhaps the melting temperature).
Heat Input Model Tuning o Tuning the heat input to match known quantities, such as expected interpass temperature, is acceptable but not required.
o In all cases, the analyst should visually confirm that the entire weld bead reaches the melting temperature. The material surrounding the weld bead should also reach the melting temperature, such that the size of the fusion zone in the actual weld is matched as closely as possible.
Structural and Thermal Boundary Conditions o In general, boundary conditions should represent the physical situation being modeled.
As such, they can change from application to application.
o For a typical dissimilar metal butt weld, axial displacement in one node, located away from the weld at the edge of the model, should be constrained (see [11] for more information).
5-12 o For a weld to infinitely-long straight pipe, the modeled pipe length should be 4 times the ID to avoid edge effects.
o For the nozzle and pipe cross-sections typically of interest in reactor coolant pressure boundary welds, heat convection at the surface is negligible compared to conduction through the part.
Material Properties o The average of isotropic and nonlinear kinematic is the recommended hardening approach.
o The temperature-dependent material properties provided to the Phase 2b round-robin participants (see Appendix B) may be used, subject to the following constraints.
The material property inputs should accurately reflect the materials in the real situation, including temperature dependence.
The scope of material property inputs depends on the material behavior required to successfully execute all aspects of the model. For example, creep properties are required to approximate stress relaxation during postweld heat treatment.
Element Selection and Mesh o Quadrilateral, linear elements should be applied.
o Quadratic and triangular elements should be avoided in all regions of the model, because they tend to result in slight discontinuities in profiles due to more complex interpolations between Gauss points. Mesh refinement with linear elements is preferred over the use of quadratic or triangular elements.
o A fine mesh is recommended in the weld regions of the model. Approximate element size for the weld passes should be 1.00 mm2. This corresponds to 10-25 elements in a typical weld pass in reactor coolant pressure boundary nozzle welds.
o The mesh may coarsen away from the weld regions.
5.4 Proposed Validation Scheme The purpose of this Section is to develop a process to judge the quality of a particular WRS prediction. To apply the method proposed here, an analyst must create an FE model of the Phase 2b mockup according to the guidelines of Section 5.3 and reference [7]. Then, the analyst calculates a series of quality metrics to judge how well the analysts prediction agrees with the round robin dataset. This validation methodology was developed assuming that the end application is a deterministic flaw growth calculation. As such, flaw growth studies were performed here to inform development of the metrics and acceptance measures. Section 5.5 summarizes the entire validation process, while Section 5.6 gives additional recommendations on modeling a real application.
5.4.1 Overview of Approach As discussed in [19], validation of a model determines how well the model reflects the physical system being approximated. A validation approach requires a benchmark, a set of metrics, and acceptance measures. Section 5.4.2 describes the recommended benchmark and associated justification. The recommended metrics and acceptance measures were based on a flaw growth argument. The concept applied here was to find a set of metrics that were relevant to flaw growth predictions. The metrics should, therefore, interrogate features of a residual stress curve that are
5-13 important to flaw growth. Two metrics are proposed here for validating FE predictions of residual stress:
- 1. RMSE on WRS magnitude through the entire wall thickness
- 2. Average difference up to the initial crack depth Sections 5.4.7, 5.4.8, and 5.4.10 describe and develop these metrics in detail. Each metric will have associated acceptance measures. The proposed acceptance measures are based on values of the metric that lead to a reasonable crack growth prediction, given the chosen benchmark. Sections 5.4.9 and 5.4.11 develop these acceptance measures. Additional analysis of potential metrics and acceptance measures appears in Appendix D. While the recommended acceptance measures were developed assuming an average hardening benchmark, corresponding criteria assuming an isotropic hardening benchmark are included in Sections 5.4.8 and 5.4.10 for illustration purposes. Additional analysis of potential metrics and acceptance measures for isotropic hardening appears in Appendix E.
5.4.2 Benchmark Validation first requires choice of a benchmark that reflects the real world. The predictions of the model can then be quantitatively compared to the benchmark to assess the robustness of the modeling approach. Often, physical measurements are a natural choice of benchmark. In the application of concern here, there are four possibilities for a benchmark.
- 1. DHD measurement data
- 2. contour measurement data
- 3. average of 1 and 2
- 4. mean of the Phase 2b models In the case of WRS, the measurement data is part physical measurement and part model, since residual stress cannot be directly measured. This fact complicates the rigorous selection of a benchmark for validating residual stress predictions. Lewis and Brooks [13] compared the Phase 2b DHD and contour measurement results to each other using the same methodology outlined in Section 5.2.1 for comparing models to measurements. Figure 5-6 suggests that the two measurements are significantly different than each other, especially near the inner surface. The flaw growth calculations in Chapter 4 show that the differences between the contour and DHD measurements lead to different flaw growth results. Averaging the two measurements (option 3) may not be a valid option, since there is no reason to believe that the two datasets belong to the same population. While a benchmark based upon the measurements may be ideal, parsing out which measurement is most correct (option 1 or option 2) requires a more thorough investigation than was performed in this work. The analysis in Section 5.2 suggests that the average hardening modeling results provide reasonable predictions of the measurement data. Given the complications associated with the measurement benchmark and the analysis in Section 5.2, the mean of the average hardening models from the Phase 2b study was chosen as a benchmark for demonstrating how a validation process may be developed.
5-14 Figure 5-6 Comparison of DHD and Contour Axial Stress Predictions (a) Raw Data and (b) Difference in Means 5.4.3 Circumferential Flaw Growth - Isotropic Hardening Figure 5-7 shows the seven smoothed isotropic WRS profiles that passed the initial outlier screening discussed in Section 3.2.2. These profiles represent the axial WRS predictions from the Phase 2b study, along with the mean WRS profile. The mean profile is the mean of six of the predictions in Figure 5-7. Although prediction B was screened out of certain calculations, as
5-15 described in Section 3.2.8, it is included in this discussion for illustrative purposes. The mean profile in Figure 5-7 is the cross-sectional mean, as described in [13].
Figure 5-7 Smoothed Axial WRS Profiles and Mean, Isotropic Hardening The flaw growth study in Chapter 4 (see Table 4-1) was repeated assuming a circumferential flaw and the residual stress profiles in Figure 5-7. The results are shown in Figure 5-8.
Figure 5-8 Circumferential Flaw Growth, Isotropic Hardening
5-16 As mentioned in Chapter 4, 720 months is much longer than a typical industry flaw analysis.
However, decreasing the evaluation period did not affect the metrics and acceptance measures (see Appendix E). The mean WRS profile exhibited flaw growth to 45 % through-wall in 250 months, followed by flaw arrest. Three other residual stress predictions (D, E, and G) led to arrest at 45-50 % through-wall. The other four WRS profiles (A, B, C, and F) led to different crack growth behavior. Using participant Bs WRS profile, the flaw grew through-wall in under 200 months. The remaining calculations showed negligible growth throughout the evaluation period.
This qualitative discussion of the different flaw growth predictions aids in establishing quantitative acceptance measures for the three quality metrics proposed in Sections 5.4.8 and 5.4.10. WRS predictions D, E, and G are considered reasonable, given that they result in similar end-of-life flaws as the proposed benchmark.
5.4.4 Circumferential Flaw Growth - Average Hardening Figure 5-9 shows the seven smoothed average hardening WRS profiles that passed the initial outlier screening discussed in Section 3.2.2. These profiles represent the axial WRS predictions from the Phase 2b study, along with the cross-sectional mean WRS profile.
Figure 5-9 Smoothed Axial WRS Profiles, Average Hardening The flaw growth results are shown in Figure 5-10. Once again, as mentioned in Chapter 4, 720 months is much longer than a typical industry flaw analysis. However, decreasing the evaluation period did not affect the metrics and acceptance measures (see Appendix D).
5-17 Figure 5-10 Circumferential Flaw Growth, Average Hardening In comparison to the isotropic case in Figure 5-8, there is more uncertainty in the flaw growth prediction. It is also apparent that the average hardening WRS predictions led to through-wall flaw growth, while three cases arrested for the isotropic curves. The averaging approach tends to decrease the magnitude of tensile and compressive stress peaks, relative to isotropic hardening.
On the one hand, the shallower compressive troughs of average hardening speeds up crack growth and leads to more cases that go through-wall. On the other hand, arresting of the flaws with isotropic hardening decreases uncertainty, since the exact magnitude of the compressive trough is only important in cases where the flaw has not arrested. As will be shown in Section 5.4.9, these variances lead to different approaches to determining appropriate acceptance measures. Therefore, the exact values of the acceptance measures are dependent upon the choice of the benchmark in the approach adopted here.
5.4.5 Axial Flaw Growth - Isotropic Hardening Figure 5-11 shows the seven smoothed hoop WRS profiles that passed the initial screening described in Section 3.2.2, assuming isotropic hardening. The hoop stresses are distinct from the axial stresses in that there is no force balance requirement through the wall thickness, given path data extracted from an axisymmetric analysis. While the area under the curve of an axial stress profile extracted from an axisymmetric FE model will be roughly zero, that of a hoop stress profile may be non-zero. These differences are apparent in the smoothed curves of Figure 5-7 and Figure 5-11.
5-18 Figure 5-11 Smoothed Hoop WRS Profiles, Isotropic Hardening Figure 5-12 shows the axial flaw growth results, assuming the residual stress profiles of Figure 5-11. The results appear much more consistent among the various stress inputs than was observed for the circumferential flaw growth study in Figure 5-8. This result is a consequence of the hoop residual stresses being either positive or only slightly negative in the initial flaw depth zone. With the axial stresses being compressive in the initial flaw depth zone, the exact magnitude of the compressive stress can have a large impact on the flaw growth early in time.
Whereas the axial flaw will always exhibit early growth in the depth direction, the circumferential flaw may or may not, depending on the interaction of the residual stresses with operating loads.
5-19 Figure 5-12 Axial Flaw Growth, Isotropic Hardening Prediction A is unique in that it led to crack arrest at 50 % through-wall for an axial flaw. All other residual stress predictions led to through-wall growth in under 200 months. Table 5-5 shows the time to through-wall for each prediction, with a value of 1,000 months assigned to prediction A to represent essentially infinite. These observations will inform quality metrics for hoop stress predictions using isotropic hardening.
Table 5-5 Time to Through-Wall
5-20 5.4.6 Axial Flaw Growth - Average Hardening Figure 5-13 shows the seven smoothed hoop WRS profiles that passed the initial screening described in Section 3.2.2, assuming average hardening.
Figure 5-13 Hoop WRS Profiles, Average Hardening Figure 5-14 shows the corresponding crack growth results.
Figure 5-14 Axial Flaw Growth, Average Hardening As was seen for the circumferential crack case, the uncertainty in time to through-wall increases for average hardening relative to the isotropic results shown in Figure 5-12. This increase in
5-21 uncertainty is due to the fact that the averaging process broadened the tensile concave-down region in the first 50 % of the wall thickness. The effect is illustrated more clearly in Figure 5-15, which shows the stress intensity factors as a function of time for the first 200 months. The time of the initial peak in stress intensity factor is much more variable for the average hardening law case.
Figure 5-15 Stress Intensity Factor: (a) Isotropic Hardening and (b) Average Hardening 5.4.7 Overview of Quality Metrics To complete the validation procedure, an analyst must complete an FE model of the Phase 2b mockup with isotropic hardening. The analyst then extracts WRS data from a weld centerline path (because that is the location at which the DHD and contour data were measured for comparison).
The analyst may also smooth the extracted profile, provided that the smoothed WRS profile is representative of the original. The extracted profile and the cross-sectional mean profiles shown
5-22 in Figure 5-7 and Figure 5-11 are then used to calculate two quality metrics. This section develops the recommended metrics.
The first quality metric involves RMSE averaged through the entire wall thickness, as described in Equation 5-3.
(
)
=
=
L k
mean k
k WRS WRS WRS L
RMSE 1
2 1
Equation 5-3 where k and L are the same as in Equation 5-2, WRSk is the analysts predicted stress magnitude at the kth position through the wall thickness, and WRSkmean is the cross-sectional mean prediction (see [13]). For the analyst to complete this step, the WRS values from the analysts FE calculation should be extracted at the same spatial intervals as those shown in Appendix C (i.e.,
every 1 % of the thickness). This quality metric provides an overall measure of how close the predicted stress magnitudes are to the mean of the Phase 2b isotropic hardening predictions.
The second quality metric is average difference over the initial flaw depth. This metric is related to the importance of the stress prediction over the distance corresponding to the initial flaw depth (the first 10 % of wall thickness, in this case). The stress magnitude and trends in this area have a profound impact on circumferential flaw growth behavior, as discussed further in Section 5.4.8.
This metric is calculated according to Equation 5-6.
(
)
=
=
1.0 1
1.0 1
L k
mean k
k avg WRS WRS L
diff Equation 5-6 where L0.1 is the number of spatial locations where WRS is determined up to xnorm=0.1.
5.4.8 Quality Metrics for Axial Stress Predictions This section explores how the proposed metrics can be applied to discriminate between axial residual stress predictions, with reference to the circumferential flaw growth studies presented in Sections 5.4.3 and 5.4.4. As such, two approaches are considered here: one using the isotropic hardening predictions and the other using the average hardening predictions. This discussion leads to proposing acceptance measures for each of the metrics. Final recommendations on acceptance measures are presented in Section 5.4.9.
Table 5-6 shows the two quality metrics applied to the seven isotropic predictions. The entries are sorted according to how the corresponding circumferential crack growth prediction compared with the mean prediction (see Figure 5-8). The prediction was deemed to yield similar flaw growth results as the benchmark if the final flaw depth was within 10 % of the wall thickness (i.e., within a/t=0.1) of the benchmark case. Thus, predictions D, E, and G were deemed to yield acceptable flaw growth results.
5-23 Table 5-6 Quality Metrics Applied to Phase 2b Axial Isotropic Predictions Table 5-6 demonstrates that RMSEWRS alone is not a sufficient measure of the quality of the prediction. For example, RMSEWRS for prediction C was the minimum of the seven predictions at 43 MPa. However, diffavg for prediction C was -55 MPa. Figure 5-16 shows a plot of prediction C compared against the mean WRS. The fact that prediction C was below the mean for the first 10 % of the wall thickness severely impacted the flaw growth calculation, such that the flaw never grew. Therefore, it is important that diffavg be closer to zero in order to obtain the expected crack growth behavior.
Figure 5-16 Prediction C (Isotropic) against the Mean Prediction Participant RMSE WRS [MPa] diff avg [MPa]
Crack Growth D
52 8 Similar E
48 22 Similar G
74
-1 Similar B
109 120 Too Fast A
78
-84 Too Slow C
43
-55 Too Slow F
67
-16 Too Slow Min 43
-84 25th percentile 50
-36 Median 67
-1 75th percentile 76 15 Max 109 120
5-24 Since the flaw growth results were more variable for average hardening (see Figure 5-10),
discriminating between good and bad predictions requires a different thought process. In the case of average hardening, the authors chose the 3 predictions (roughly, the top 50 %) that matched closest to the benchmark as acceptable WRS predictions. For this case, predictions D, E, and G were again considered acceptable. Table 5-7 shows the values of the quality metrics for each of the average hardening predictions.
Table 5-7 Quality Metrics Applied to the Phase 2b Axial Average Hardening Predictions 5.4.9 Recommended Acceptance Measures - Axial Residual Stress While the analysis in Section 5.4.8 was applied to both the isotropic hardening and average hardening datasets, the final recommended acceptance measures should be based on one or the other. The discussion in Section 5.2 indicated that the averaging approach may be preferable to isotropic hardening. Therefore, the recommend acceptance measures is based upon the analysis of the average hardening dataset in Table 5-7. In general, the recommended acceptance measures are based upon values of the metric that (1) screen out those WRS curves that lead to unreasonable crack growth predictions and (2) screen in those curves that lead to reasonable crack growth predictions. For RMSEWRS, the recommended criterion is RMSEWRS55 MPa. The recommended acceptance criterion for diffavg is -15 MPa diffavg15 MPa.
5.4.10 Quality Metrics for Hoop Stress Predictions Table 5-8 shows the two quality metrics for the seven isotropic hoop stress predictions, sorted according to time to through-wall (see Figure 5-12).
Participant RMSE WRS [MPa] diff avg [MPa] Delta from Mean Time to leakage D
29
-10 71 512 E
32 11
-181 260 G
52 14
-86 355 B
79 92
-338 103 A
59
-55 559 1000 C
28
-31 408 849 F
46
-20 559 1000 Min 28
-55 103 25th percentile 30
-26 308 Median 46
-10 512 75th percentile 56 12 925 Max 79 92 1000
5-25 Table 5-8 Quality Metrics Applied to Phase 2b Hoop Isotropic Predictions The time to leakage assuming the mean hoop residual stress profile in Figure 5-11 was 105 months.
This value was considered as a benchmark for this discussion. The times to leakage assuming Participant G, E, and Cs residual stress profiles were each within 36 months of this value. Thirty-six months corresponds to the length of time for two refueling outages. Participant Es case is straightforward, in each quality metrics were relatively low in magnitude. Participant G, on the other hand, had a high RMSEWRS value of 82 MPa. Figure 5-17 compares Participant Gs prediction against the mean curve. The high value of the WRS for 0.1<r/t<0.3 is apparent. However, the relatively low diffavg and close agreement of the curves in other spatial locations led to an acceptable flaw growth result.
Participant RMSE WRS [MPa] diff avg [MPa] Delta from Mean Time to leakage D
70 95
-51 54 E
49 23
-7 98 G
82 23
-29 76 B
114 156
-61 44 A
86
-68 895 1000 C
53
-71 23 128 F
59 1
33 138 Min 49
-71 44 25th percentile 56
-34 65 Median 70 23 98 75th percentile 84 59 133 Max 114 156 1000
5-26 Figure 5-17 Hoop Stress Prediction from Participant G Prediction C is shown against the mean curve in Figure 5-18. For the circumferential flaw growth, a negative diffavg could easily lead to complete arrest of the flaw. This is not the case for axial flaw growth. When operating loads are superimposed on the hoop stresses, the flaw still grows in the depth direction. Even though Participant Cs diffavg was -71 MPa, a reasonable time to leakage of 128 months was still possible. However, diffavg remains an important metric for the hoop stresses, as demonstrated by Participant D (Figure 5-19). Participant Ds diffavg was highly positive, and this led to a short time to leakage of 54 months, as compared to the assumed benchmark of 105 months.
5-27 Figure 5-18 Hoop Stress Prediction from Participant C Figure 5-19 Hoop Stress Prediction from Participant D Since the flaw growth results were more variable for average hardening (see Figure 5-14),
discriminating between good and bad predictions requires a different thought process. As was
5-28 proposed in Section 5.4.8, the authors chose the 3 predictions (roughly, the top 50 %) that matched closest to the benchmark as acceptable WRS predictions. For this case, predictions D, E, and G were again considered acceptable. Table 5-9 shows the values of the quality metrics for each of the average hardening predictions.
Table 5-9 Quality Metrics Applied to Phase 2b Hoop Average Hardening Predictions 5.4.11 Recommended Acceptance Measures - Hoop Residual Stress While the analysis in Section 5.4.10 was applied to both the isotropic hardening and average hardening datasets, the final recommended acceptance measures should be based upon one or the other. The discussion in Section 5.2 indicated that the averaging approach may be preferable to isotropic hardening. Therefore, the recommend acceptance measures is based upon the analysis of the average hardening dataset in Table 5-9. In general, the recommended acceptance measures are based on values of the metric that (1) screen out those WRS curves that lead to unreasonable crack growth predictions and (2) screen in those curves that lead to reasonable crack growth predictions. For RMSEWRS, the recommended criterion is RMSEWRS70 MPa. The recommended acceptance criterion for diffavg is 0diffavg65 MPa.
5.5 Summary of Validation Procedure This section is a final summary of the validation procedure developed in this Chapter.
- 1. The analyst executes an axisymmetric FE model of the Phase 2b mockup, according to the guidelines in Section 5.3 and reference [7]. The model should be run twice: once with isotropic hardening properties and once for nonlinear kinematic hardening properties (see Appendix B).
- 2. The analyst extracts a number of WRS profiles from the FE results.
- a. axial and hoop WRS for isotropic hardening
- b. axial and hoop WRS for nonlinear kinematic hardening The profiles should be extracted from the centerline location because that is where DHD data was available for comparison. The analyst may smooth the FE WRS profiles (see Participant RMSE WRS [MPa] diff avg [MPa] Delta from Mean Time to leakage D
49 47
-91 112 E
26 13
-31 172 G
68 63
-87 116 B
74 114
-121 82 A
51
-37 517 720 C
34
-56 137 340 F
50
-30 288 491 Min 26
-56 82 25th percentile 42
-33 114 Median 50 13 172 75th percentile 60 55 416 Max 74 114 720
5-29
[13] for one approach), provided the smoothed profiles are reasonable representations of the FE results. The final WRS profiles should consist of 100 uniformly-spaced data points.
- 3. The analyst should average the axial nonlinear kinematic and isotropic WRS profiles to obtain an axial average hardening profile. The analyst should repeat this step for hoop WRS.
- 4. The analyst calculates the first derivative of the WRS profiles. If an analytical form of the WRS profiles is available (e.g., as obtained from smoothing), then the profiles may be differentiated analytically. Otherwise, Equation 5-4 may be used as an approximation to the first derivative.
- 5. The means of the average hardening Phase 2b predictions, along with their first derivatives, are given in tabular form in Appendix C. These values are needed for step 6.
- 6. Using the data gathered in steps 2-5, the analyst should calculate the two quality metrics; RMSEWRS and diffavg; according to the equations given in Section 5.4.7. The analyst should calculate diffavg according to the initial flaw depth of interest. In the absence of other information, the analyst may assume a/t=0.1 initial flaw depth.
- 7. The analyst compares the calculated values with the acceptance measures summarized in Table 5-10 and Table 5-11.
- 8. If all acceptance measures are met, then the analyst has passed the validation exercise.
The analyst proceeds to step 10.
- 9. If one or more acceptance measures are not met, then the analyst and an independent individual in the organization should carefully review the model.
- a. They should verify that (i) all modeling guidelines in Section 5.3 were followed, (ii) all dimensions were correct, and (iii) all material property inputs were correct.
- b. They should discuss whether any improvements can be made to the model (e.g.,
refined mesh in a specific geometric region).
- c. If the model can be improved, then the analyst should rerun the model and repeat the validation exercise with the new results.
- 10. The analyst should document the validation exercise, including any lessons-learned during the process. An independent individual in the organization should review the validation exercise.
Table 5-10 Acceptance Measures for Axial Stresses Quality Metric Acceptance Criteria RMSEWRS 55 MPa diffavg
- 15 MPa 15 MPa Table 5-11 Acceptance Measures for Hoop Stresses Quality Metric Acceptance Criteria RMSEWRS 70 MPa diffavg
- 0 MPa 65 MPa
5-30 5.6 Modeling a Nuclear Plant Application The approach outlined in Section 5.5 provides a means for an analyst to demonstrate capability in FE modeling of WRS. The approach uses an existing dataset related to a prototypical mockup to draw conclusions about validation criteria. This section provides recommendations for advancing from the validation stage to modeling real components.
5.6.1 Applicability of Validation Scheme and Acceptance Measures The proposed validation scheme is most directly applicable to a dissimilar metal butt weld. Some details such as constraint condition, repair geometry and location, safe end length, and radius-to-thickness ratio need not be identical to the Phase 2b mockup to be considered covered by the validation process proposed in this document. However, there are potential scenarios encountered in the U.S. nuclear fleet where a validation approach based on the Phase 2b dataset is not appropriate.
One example of additional benchmark data is the mockup dataset from the excavate and weld repair (EWR) investigation [30]-[33]. EWR was proposed as a partial arc repair process, as illustrated in Figure 5-20 [33]. Therefore, three-dimensional analysis methods were required to adequately assess residual stresses for this process. The mockup shown in Figure 5-21 was designed such that a 3D analysis was required. The measurement data from this mockup can therefore be used to benchmark a 3D analytical procedure applied to EWR, but the Phase 2b data would not be appropriate. In a similar vein, modeling residual stress in a control rod drive mechanism nozzle (i.e., j-groove weld) would require a validation dataset more representative of that application.
Figure 5-20 A Partial Arc Weld Repair
5-31 Figure 5-21 EWR Mockup Furthermore, the validation metrics and associated acceptance measures in Section 5.4 are most directly applicable to a dissimilar metal butt weld case. The metrics and acceptance measures would likely have to be redeveloped for other applications. When developing new metrics and acceptance measures, the user should carefully consider the end use of the model results. The work presented here was focused on flaw growth calculations, so the metrics and acceptance measures were developed with a flaw growth argument in mind. The same philosophy should be applied to broader applications of this approach.
5.6.2 Welding Process The Phase 2b mockup was fabricated with a combination of gas tungsten arc welding and shielded metal arc welding [7]. The typical weld bead cross-sectional area was around 35 mm2, with some variation. Submerged arc welding is often characterized by higher deposition rate, higher heat input, and larger weld beads than the gas tungsten arc and shielded metal arc processes. Large weld beads and high heat inputs can lead to large nodal displacements in an FE model. For these reasons, the proposed validation scheme may not be applicable to submerged arc welding.
5.6.3 Hardening Law Hardening law has large influence on the results of WRS predictions using FE. Since hardening law is a matter of material behavior, the recommendations on hardening law should not change from application to application. However, if the requisite material data are available, future investigators should continue to study hardening law, including consideration of the Lemaitre-Chaboche approach.
5-32 5.6.4 Best Practices for a Plant Application When modeling a plant application, the analyst should generally apply the modeling guidelines of Section 5.3. Any lessons-learned through the validation process should also be applied. In general, the model should represent the physical situation as closely as possible, including (but not limited to) mechanical constraint condition, groove geometry, material properties, number and size of weld passes and layers, and thermal boundary conditions. Inclusion of a repair weld in the model according to MRP-287 [36] may be advisable, unless plant records demonstrate that such a repair does not exist.
5.7 Conclusion The procedure recommended in this chapter consists of two aspects: (1) modeling guidelines developed over the course of the EPRI/NRC WRS Validation Program and (2) a validation procedure developed from results of the Phase 2b round robin study. These recommendations drew heavily on the uncertainty quantification methodology presented in Chapter 3. Validation against the Phase 2b dataset is most directly applicable to axisymmetric FE models of dissimilar metal butt welds. This process may be adapted to other applications as discussed in Section 5.6.1, but the analyst should first evaluate whether additional data are needed. For instance, additional WRS measurement data may be needed for unique geometries or welding processes.
The modeling guidelines presented in Section 5.3 were principally drawn from the recommendations of MRP-316 [2]. Many of these guidelines were also provided to the Phase 2b participants, as in reference [7]. The same bootstrapping methods discussed in Chapter 3 were used in Section 5.2.1 to develop a method to compare uncertain FE predictions to uncertain measurements. This led to RMSE and associated confidence bounds, as shown in Figure 5-4 and Figure 5-5. The recommendation to use average hardening was based on qualitative (Table 5-2) and quantitative assessments (Figure 5-4 and Figure 5-5). The Phase 2b study did not include the mixed hardening law. Future work should address mixed hardening law.
Development of a potential validation process involved proposing a benchmark, a set of metrics, and acceptance measures. Choice of a benchmark proved to be challenging due to difficulties in discriminating between measurements that do not entirely agree (see Section 5.4.2). The quality metrics for validation were developed in Section 5.4.7. They include the RMSE on WRS magnitude averaged over the entire wall thicknessand the average difference up to the initial crack depth. The acceptance measures (Table 5-10 and Table 5-11) were developed based on results of flaw growth calculations. The quality metrics, and their associated acceptance measures, were chosen as a way to ensure a reasonable flaw growth prediction.
6-1 6
CONCLUSIONS This document describes a validation process for FE modeling of WRS and the associated technical background. The validation process was based on the Phase 2b round robin dataset.
This dataset consisted of 2 sets of measurement results (contour and DHD) and 10 independent predictions based on axisymmetric FE modeling. Chapter 2 and reference [7] discuss the round-robin study in greater detail. The Phase 2b dataset was input into an uncertainty analysis procedure as the first step in developing the WRS guidelines.
The characterization of WRS uncertainty started with the recognition that WRS is functional data.
In other words, the magnitude of the stress depends on the spatial location within the component.
Using the methods of [15]-[16], a statistical model of the dataset was created. This model enabled bootstrapping techniques for the determination of appropriate confidence bounds and 95/95 tolerance bounds. Chapter 3 describes this methodology, with further details contained in reference [13].
Chapter 4 of this document explores the impacts of WRS variations on flaw growth calculation. It examines several features of the stress curve (i.e. residual plus operating stresses), including the inner surface stress, the stress at the initial flaw depth, and the through-wall positions where the curve crossed zero. Regulatory staff can review these features to gain confidence in an assumed WRS input found in an industry licensing submittal. A potential review strategy is to compare these features to a reference WRS curve. The reference WRS curve may come from previously-accepted curves or from confirmatory analyses. WRS impacts on flaw growth calculations were also used in Section 5.4 to define quality metrics and acceptance measures for the validation procedure.
The WRS modeling guidance presented here was largely based on reference [11]. However, additional work was performed here to explore three different hardening law choices: isotropic, nonlinear kinematic, and the average of isotropic and kinematic. Qualitative and quantitative comparisons of measurements to models (see Section 5.2) led to average hardening as the recommend hardening approach. Future work should consider mixed hardening as an option.
Three quality metrics were developed in Section 5.4 for the validation process: RMSE on WRS magnitude averaged over the entire wall thicknessand the average difference up to the initial crack depth. These metrics and associated acceptance measures (see Table 5-10 and Table 5-11) were chosen in a way that promoted reasonable flaw growth results using the Phase 2b WRS predictions.
The validation procedure and WRS input guidelines developed in this document provide a potential method for increasing confidence in WRS predictions for nuclear power applications.
Such a process may lead to more efficient NRC reviews of industry submittals and increased regulatory certainty. Actual implementation of the suggestions in this document will depend upon further interactions with industry representatives and consensus standards bodies.
7-1 7
REFERENCES
[1]
U.S. Nuclear Regulatory Commission, NUREG-2162, Weld Residual Stress Finite Element Analysis Validation: Part I - Data Development Effort, Washington, DC, March 2014 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML14087A118).
[2]
Electric Power Research Institute, MRP-316 Revision 1, Materials Reliability Program:
Finite-Element Model Validation for Dissimilar Metal Butt-Welds, Report 3002005498, Palo Alto, CA, September 2015.
[3]
U.S. Nuclear Regulatory Commission/Electric Power Research Institute, NUREG-2110/EPRI 1022860, xLPR Pilot Study Report, Washington, DC, February 2012.
[4]
D. Rudland and C. Harrington, Initial Development of the Extremely Low Probability of Rupture (xLPR) Version 2.0 Code, Proceedings of the ASME Pressure Vessels and Piping Conference, PVP2012-78186, Toronto, Canada, July 2012.
[5]
Robert E. Kurth, Cedric J. Sallaberry, Frederick W. Brust, Elizabeth A. Kurth, Michael L.
Benson, and David L. Rudland, Uncertainty Sampling of Weld Residual Stress Fields in Probabilistic Analysis: Part I Theory, Proceedings for the 2016 ASME Pressure Vessels and Piping Conference, PVP2016-63962, Vancouver, Canada, July 2016.
[6]
Robert E. Kurth, Cedric J. Sallaberry, Frederick W. Brust, Elizabeth A. Kurth, Michael L.
Benson, and David L. Rudland, Uncertainty Sampling of Weld Residual Stress Fields in Probabilistic Analysis: Part II Example, Proceedings for the 2016 ASME Pressure Vessels and Piping Conference, PVP2016-63963, Vancouver, Canada, July 2016.
[7]
U.S. Nuclear Regulatory Commission, Phase 2b Finite Element Round Robin Results, Technical Letter Report, Washington, DC, December 2015 (ADAMS Accession No. ML16020A034).
[8]
H. J. Rathbun, L. F. Fredette, P. M. Scott, A. A. Csontos, and D. L. Rudland, "NRC Welding Residual Stress Validation Program International Round Robin Program and Findings,"
Proceedings of the ASME Pressure Vessels and Piping Conference, PVP2011-57642, Baltimore, MD, July 2011.
[9]
L. F. Fredette, M. Kerr, H. J. Rathbun, and J. E. Broussard, "NRC/EPRI Welding Residual Stress Validation Program: Phase III - Details and Findings," PVP2011-57645, Proceedings of the ASME Pressure Vessels and Piping Conference, Baltimore, MD, July 2011.
[10]
M. Kerr, D. L. Rudland, M. B. Prime, H. Swenson, M. A. Buechler, and B. Clausen, Characterization of a Plate Specimen from Phase I of the NRC/EPRI, Weld Residual Stress Program, PVP2011-57687, Proceedings of the ASME Pressure Vessels and Piping Conference, Baltimore, MD, July 2011.
[11]
Electric Power Research Institute, MRP-317, Revision 1, Materials Reliability Program:
Welding Residual Stress Dissimilar Metal Butt Weld Finite Element Modeling Handbook, Report 3002005499, Palo Alto, CA, September 2015.
[12]
Michael L. Benson, Frederick W. Brust, Robert E. Kurth, and John E. Broussard, Weld Residual Stress Inputs for a Probabilistic Fracture Mechanics Code, PVP2014-28030, Proceedings of the ASME Pressure Vessels and Piping Conference, Anaheim, CA, July 2014.
[13]
J. R. Lewis and D. Brooks, Uncertainty Quantification and Comparison of Weld Residual Stress Measurements and Predictions, Sandia National Laboratory, SAND2016-10932, October 2016 (ADAMS Accession No. ML16301A055).
[14]
J. R. Lewis, D. Brooks, and M. L. Benson, Methods for Uncertainty Quantification and Comparison of Weld Residual Stress Measurements and Predictions, Proceedings of the ASME Pressure Vessels and Piping Conference, PVP2017-65552, Waikoloa, HI, July 2017.
7-2
[15]
J. O. Ramsay and B. W. Silverman, Functional Data Analysis, Springer, New York, NY, 1997.
[16]
J. Derek Tucker, Wei Wu, and Anuj Srivastava, Generative Models for Functional Data Using Phase and Amplitude Separation, Comparative Statistics and Data Analysis, 61:50-66, 2013
[17]
Anthony C. Davison and David V. Hinkley, Bootstrap Methods and Their Application, Volume 2, Cambridge University Press, 1997.
[18]
Anthony C. Davison, David V. Hinkley, and G. Alastair Young, Recent Developments in Bootstrap Methodology, Statistical Science, 18:141-157, 2003.
[19]
Minh N. Tran, Michael R. Hill, and Mitchell D. Olson, Further Comments on Validation Approaches for Weld Residual Stress Simulation, Proceedings of the ASME Pressure Vessels and Piping Conference, PVP2015-45751, Boston, MA, July 2015.
[20]
Erwin Kreyszig, Advanced Engineering Mathematics, 9th Edition, John Wiley & Sons, Inc.
Hoboken, NJ, 2006.
[21]
G. J. Hahn and W. Q. Meeker, Statistical Intervals: A Guide for Practitioners, Vol. 328, John Wiley & Sons, Hoboken, NJ, 2011.
[22]
American Society of Mechanical Engineers, Boiler and Pressure Vessel Code,Section XI (2015), Rules for Inservice Inspection of Nuclear Power Plant Components, New York, NY, July 2015.
[23]
American Society of Mechanical Engineers, Code Case N-770, Alternative Examination Requirements and Acceptance Standards for Class 1 PWR Piping and Vessel Nozzle Butt Welds Fabricated with UNS N06082 or UNS W86182 Weld Filler Material with or without Application of Listed Mitigation Activities, New York, NY, June 2011.
[24]
Memorandum to G. T. Powell from Robert J. Pascarelli, South Texas Project, Unit 2 -
Request for Relief No. RR-ENG-3-20 for Extension of the Inspection Frequency of the Reactor Vessel Cold-Leg Nozzle to Safe-End Welds with Flaw Analysis, June 30, 2016 (ADAMS Accession No. ML16174A091).
[25]
Electric Power Research Institute, MRP-115NP, Crack Growth Rates for Evaluating Primary Water Stress Corrosion Cracking of Alloy 82, 182, and 132 Welds, Report 1006696, Palo Alto, CA, November 2004.
[26]
American Petroleum Institute, API 579-1/ASME FFS-1, Fitness-for-Service, Washington, DC, 2007.
[27]
S. X. Xu, D. A. Scarth, and R. C. Cipolla, Technical Basis for Proposed Weight Function Method for Calculation of Stress Intensity Factor for Surface Flaws in ASME Section XI Appendix A, Proceedings of the 2011 ASME Pressure Vessel Piping Conference, PVP2011-57911, Baltimore, MD, July 2011.
[28]
S. X. Xu, D. A. Scarth, and R. C. Cipolla, Calculation of Stress Intensity Factor for Surface Flaws Using Universal Weight Functions with Piece-Wise Cubic Stress Interpolation, Proceedings of the ASME Pressure Vessels and Piping Conference, PVP2012-78236, Toronto, Canada, July 2012.
[29]
Electric Power Research Institute, MRP-216, Materials Reliability Program: Advance FEA Evaluation of Growth of Postulated Circumferential PWSCC Flaws in Pressurizer Nozzle Dissimilar Metal Welds, Report 1015400, Palo Alto, CA, August 2007.
[30]
U.S. Nuclear Regulatory Commission, Weld Residual Stress Analysis of Excavate and Weld Repair Mockup, Technical Letter Report, Washington, DC, September 2016 (ADAMS Accession No. ML16257A523).
[31]
Mitchell D. Olson, Adrian T. DeWald, Michael R. Hill, and Steven L. McCracken, Residual Stress Mapping for an Excavate and Weld Repair Mockup, Proceedings of the ASME Pressure Vessels and Piping Conference, PVP2016-63197, July 2016.
7-3
[32]
Francis H. Ku, Pete C. Riccardella, and Steven L. McCracken, 3D Residual Stress Simulation of an Excavate and Weld Repair Mockup, Proceedings of the ASME Pressure Vessels and Piping Conference, PVP2016-63815, July 2016.
[33]
Steven McCracken, Jonathan Tatman, and Pete Riccardella, Technical Basis for Code Case N-847 - Excavate and Weld Repair for SCC Mitigation, Proceedings of the ASME Pressure Vessels and Piping Conference, PVP2016-63769, July 2016.
[34]
J. Lemaitre and J.-L. Chaboche, Mechanics of Solid Materials, Cambridge University Press, Cambridge, United Kingdom, 1990.
[35]
Richard L. Burden and J. Douglas Faires, Numerical Analysis, 6th Edition, Brooks/Cole Publishing Company, Albany, NY, 1997.
[36]
Electric Power Research Institute, MRP-287, Materials Reliability Program: Primary Water Stress Corrosion Cracking (PWSCC) Flaw Evaluation Guidance, Report 1021023, Palo Alto, CA, December 2010.
A-1 MODEL-MEASUREMENT COMPARISONS This appendix contains all relevant data plots for model-measurement comparisons, including the calculated mean difference function and associated confidence bounds. It includes a plot for each case described in Section 5.2.2.
APPENDIX A
A-2 Figure A-1 Axial Stress Component with Nonlinear Kinematic Hardening and DHD Benchmark: (a) Stress Magnitude and (b) Difference in Means with Confidence Bounds
A-3 Figure A-2 Axial Stress Component with Isotropic Hardening and DHD Benchmark: (a)
Stress Magnitude and (b) Difference in Means with Confidence Bounds
A-4 Figure A-3 Axial Stress Component with Average Hardening and DHD Benchmark: (a)
Stress Magnitude and (b) Difference in Means with Confidence Bounds
A-5 Figure A-4 Hoop Stress Component with Nonlinear Kinematic Hardening and DHD Benchmark: (a) Stress Magnitude and (b) Difference in Means with Confidence Bounds
A-6 Figure A-5 Hoop Stress Component with Isotropic Hardening and DHD Benchmark: (a)
Stress Magnitude and (b) Difference in Means with Confidence Bounds
A-7 Figure A-6 Hoop Stress Component with Average Hardening and DHD Benchmark: (a)
Stress Magnitude and (b) Difference in Means with Confidence Bounds
A-8 Figure A-7 Axial Stress Component with Nonlinear Kinematic Hardening and Contour Benchmark: (a) Stress Magnitude and (b) Difference in Means with Confidence Bounds
A-9 Figure A-8 Axial Stress Component with Isotropic Hardening and Contour Benchmark:
(a) Stress Magnitude and (b) Difference in Means with Confidence Bounds
A-10 Figure A-9 Axial Stress Component with Average Hardening and Contour Benchmark: (a)
Stress Magnitude and (b) Difference in Means with Confidence Bounds
A-11 Figure A-10 Hoop Stress Component with Nonlinear Kinematic Hardening and Contour Benchmark: (a) Stress Magnitude and (b) Difference in Means with Confidence Bounds
A-12 Figure A-11 Hoop Stress Component with Isotropic Hardening and Contour Benchmark:
(a) Stress Magnitude and (b) Difference in Means with Confidence Bounds
A-13 Figure A-12 Hoop Stress Component with Average Hardening and Contour Benchmark:
(a) Stress Magnitude and (b) Difference in Means with Confidence Bounds
APPENDIX B B-1 MATERIAL PROPERTIES This appendix contains temperature-dependent material properties appropriate for performing the validation procedure. Tables B-1 through B-7 are the Alloy 182 weld properties. Tables B-8 through B-14 are the low alloy steel nozzle properties. Tables B-15 through B-21 are the stainless steel safe end and pipe properties. These data tables use the following conventions.
T - temperature E - elastic modulus
- Poissons ratio CTE - coefficient of thermal expansion A, n, m - parameters in the creep law m
n Aq
=
, where is the uniaxial equivalent creep strain rate, q is the uniaxial equivalent deviatoric stress, and is time Table B-1 Isotropic Hardening Law - Alloy 182 T [K]
True plastic strain [mm/mm]
True stress [MPa]
295 0.00E+00 207.3 295 1.10E-04 225.0 295 1.40E-04 242.6 295 2.10E-04 259.8 295 3.10E-04 273.2 295 4.40E-04 282.7 295 6.40E-04 290.5 295 8.60E-04 295.2 295 1.04E-03 297.8 295 2.14E-03 305.9 295 3.37E-03 310.9 295 8.21E-03 322.8 295 1.32E-02 331.9 295 1.83E-02 340.3 295 2.31E-02 347.4 295 2.82E-02 355.2 295 3.32E-02 363.1 295 3.82E-02 371.2 295 4.30E-02 379.2 295 4.80E-02 387.4
B-2 T [K]
True plastic strain [mm/mm]
True stress [MPa]
295 5.30E-02 396.0 295 5.80E-02 404.4 295 6.30E-02 413.1 295 6.80E-02 421.8 295 7.30E-02 430.7 295 7.80E-02 439.6 295 8.29E-02 448.6 295 8.79E-02 457.9 295 9.29E-02 467.1 295 9.80E-02 476.2 295 1.03E-01 484.6 295 1.08E-01 494.5 295 1.13E-01 503.0 295 1.18E-01 511.5 295 1.23E-01 521.4 295 1.28E-01 529.9 295 1.33E-01 538.4 295 1.38E-01 548.3 295 1.43E-01 556.9 295 1.49E-01 567.9 295 1.54E-01 576.4 295 1.58E-01 584.8 295 1.63E-01 593.3 295 1.69E-01 604.6 295 1.78E-01 621.3 295 1.88E-01 640.6 295 1.98E-01 659.7 295 2.08E-01 678.5 589 0.00E+00 162.8 589 1.90E-04 178.7 589 2.30E-04 194.5
B-3 T [K]
True plastic strain [mm/mm]
True stress [MPa]
589 2.90E-04 204.8 589 4.00E-04 216.5 589 5.80E-04 224.1 589 8.80E-04 229.7 589 2.86E-03 242.5 589 4.72E-03 248.8 589 6.73E-03 254.1 589 8.82E-03 259.0 589 1.87E-02 279.4 589 2.85E-02 299.6 589 3.85E-02 320.7 589 4.84E-02 340.4 589 5.84E-02 356.1 589 6.84E-02 372.5 589 7.84E-02 389.9 589 8.84E-02 402.8 589 9.89E-02 424.0 589 1.09E-01 440.8 589 1.19E-01 456.2 589 1.28E-01 470.8 589 1.38E-01 484.8 589 1.48E-01 502.3 589 1.59E-01 519.4 589 1.68E-01 531.3 589 1.79E-01 552.1 589 1.89E-01 561.7 589 1.99E-01 578.9 811 0.00E+00 169.6 811 1.60E-04 178.5 811 2.10E-04 185.3 811 2.60E-04 191.7
B-4 T [K]
True plastic strain [mm/mm]
True stress [MPa]
811 3.40E-04 197.7 811 4.30E-04 201.8 811 5.00E-04 204.2 811 6.40E-04 207.4 811 7.40E-04 209.3 811 1.07E-03 211.5 811 1.53E-03 213.5 811 2.53E-03 218.7 811 3.51E-03 221.2 811 4.53E-03 225.2 811 5.53E-03 227.3 811 6.42E-03 229.5 811 7.47E-03 230.7 811 8.48E-03 233.6 811 1.83E-02 258.4 811 2.82E-02 277.4 811 3.81E-02 295.5 811 4.81E-02 307.6 811 5.80E-02 324.8 811 6.80E-02 341.0 811 7.79E-02 350.6 811 8.78E-02 369.7 811 9.79E-02 382.8 811 1.08E-01 397.6 811 1.18E-01 409.2 811 1.28E-01 425.2 811 1.38E-01 429.5 811 1.48E-01 451.5 811 1.58E-01 462.4 811 1.68E-01 478.1 811 1.78E-01 492.1
B-5 T [K]
True plastic strain [mm/mm]
True stress [MPa]
811 1.88E-01 505.3 811 1.98E-01 518.8 1033 0.00E+00 143.7 1033 1.70E-04 152.2 1033 2.10E-04 165.7 1033 2.60E-04 175.1 1033 4.40E-04 185.5 1033 7.00E-04 191.3 1033 1.00E-03 195.0 1033 1.62E-03 199.6 1033 2.57E-03 204.0 1033 3.61E-03 207.3 1033 4.58E-03 209.8 1033 5.62E-03 212.5 1033 6.59E-03 214.9 1033 7.53E-03 217.3 1033 8.48E-03 219.6 1033 1.84E-02 244.8 1033 2.82E-02 271.9 1033 3.81E-02 297.4 1033 4.80E-02 317.6 1033 5.79E-02 331.5 1033 6.79E-02 340.6 1033 7.83E-02 345.9 1033 8.80E-02 349.8 1033 9.80E-02 353.0 1033 1.08E-01 355.3 1033 1.18E-01 357.0 1033 1.28E-01 358.3 1033 1.38E-01 359.5 1033 1.48E-01 360.3
B-6 T [K]
True plastic strain [mm/mm]
True stress [MPa]
1033 1.58E-01 361.5 1033 1.68E-01 362.6 1033 1.78E-01 363.7 1033 1.88E-01 364.7 1033 1.98E-01 365.4 1255 0.00E+00 42.6 1255 1.80E-04 43.8 1255 2.90E-04 59.8 1255 4.20E-04 73.7 1255 5.80E-04 84.8 1255 7.20E-04 91.7 1255 9.10E-04 98.2 1255 1.07E-03 102.1 1255 1.25E-03 105.6 1255 1.47E-03 108.4 1255 1.96E-03 112.0 1255 2.48E-03 113.7 1255 3.41E-03 114.6 1255 4.44E-03 114.8 1573 0.00E+00 5.0
B-7 Table B-2 Elastic Properties - Alloy 182 T [K]
E [MPa]
294.1 213750 0.290 366.3 208230 0.307 421.9 206160 0.316 477.4 203400 0.325 533.0 199960 0.334 588.6 197890 0.343 644.1 194440 0.352 699.7 190300 0.361 755.2 186170 0.370 810.8 182030 0.396 873.0 180000 0.400 973.0 172000 0.400 1073.0 164000 0.400 1173.0 154000 0.400 1273.0 143000 0.400 1375.2 115000 0.400 1533.0 78258 0.400 1588.6 39302 0.400
B-8 Table B-3 Coefficient of Thermal Expansion - Alloy 182 (Reference T0=293 K)
T [K]
CTE [K-1]
310.8 1.2420E-05 338.6 1.2726E-05 366.3 1.2960E-05 394.1 1.3158E-05 421.9 1.3320E-05 449.7 1.3500E-05 477.4 1.3626E-05 505.2 1.3752E-05 533.0 1.3860E-05 560.8 1.3986E-05 588.6 1.4076E-05 616.3 1.4184E-05 644.1 1.4292E-05 671.9 1.4382E-05 699.7 1.4472E-05 773.0 1.4900E-05 873.0 1.5300E-05 973.0 1.5800E-05 1073.0 1.6100E-05 1173.0 1.6400E-05 1366.3 1.7000E-05 1644.1 1.7800E-05
B-9 Table B-4 Creep Law - Alloy 182 T [K]
A [MPan/s]
n m
293 4.42500E-50 4.00 0
673 4.42500E-40 4.00 0
844 3.99261E-25 6.1709 0
894 3.44133E-24 6.6426 0
1644.1 1.24000E-20 6.6426 0
Table B-5 Thermal Conductivity - Alloy 182 T [K]
Thermal Conductivity
[W/mm-K]
300 1.42E-02 350 1.51E-02 400 1.60E-02 450 1.68E-02 500 1.77E-02 600 1.95E-02 700 2.13E-02 800 2.30E-02 900 2.48E-02 1000 2.65E-02 1100 2.83E-02 1200 3.01E-02 1300 3.18E-02 1400 3.36E-02 1500 3.53E-02 1600 3.71E-02 1665 3.83E-02 2000 7.66E-02
B-10 Table B-6 Specific Heat - Alloy 182 T [K]
Specific Heat [J/(g-K)]
73 2.72155E-01 123 3.14025E-01 173 3.51708E-01 223 3.85204E-01 273 4.14513E-01 373 4.60570E-01 473 4.89879E-01 573 5.10814E-01 673 5.27562E-01 773 5.44310E-01 873 5.65245E-01 973 5.90367E-01 1073 6.28050E-01 1123 6.53172E-01 Table B-7 Miscellaneous Properties - Alloy 182 Density
[g/mm3]
Latent Heat
[J/g]
Solidus
[K]
Liquidus
[K]
Anneal Temperature [K]
0.00847 297.6 1573 1618 1574 Table B-8 Isotropic Hardening Law - Low Alloy Steel T [K]
True plastic strain [mm/mm]
True stress [MPa]
295 0.0000E+00 402.3 295 3.1000E-04 417.7 295 5.0000E-04 415.4 295 7.3000E-04 415.6 295 1.0000E-03 415.8 295 1.3200E-03 415.7 295 2.3700E-03 414.3
B-11 T [K]
True plastic strain [mm/mm]
True stress [MPa]
295 3.3200E-03 416.3 295 4.3500E-03 418.6 295 5.3900E-03 418.6 295 6.4100E-03 423.1 295 7.3500E-03 427.0 295 8.3200E-03 430.5 295 1.8190E-02 472.7 295 2.8110E-02 513.1 295 3.7940E-02 545.3 295 4.7920E-02 571.8 295 5.7880E-02 592.8 295 6.7890E-02 611.9 295 7.7910E-02 624.9 295 8.7830E-02 634.9 295 9.7900E-02 642.9 295 1.0796E-01 648.8 295 1.1802E-01 651.8 295 1.2801E-01 650.5 589 0.0000E+00 268.9 589 6.0000E-05 288.6 589 1.2000E-04 308.1 589 2.7000E-04 332.1 589 4.5000E-04 343.9 589 8.0000E-04 354.3 589 1.1600E-03 361.1 589 2.1100E-03 373.6 589 3.0400E-03 382.8 589 3.9600E-03 390.4 589 4.9300E-03 397.4 589 5.9200E-03 404.0 589 6.9400E-03 410.1
B-12 T [K]
True plastic strain [mm/mm]
True stress [MPa]
589 7.8600E-03 415.3 589 1.7650E-02 461.8 589 2.7560E-02 497.5 589 3.7500E-02 525.2 589 4.7460E-02 546.5 589 5.7420E-02 563.0 589 6.7390E-02 576.1 589 7.7420E-02 586.5 589 8.7430E-02 594.5 589 9.7440E-02 599.8 589 1.0751E-01 600.4 811 0.0000E+00 186.6 811 2.6000E-04 211.2 811 3.1000E-04 226.1 811 4.0000E-04 244.2 811 5.4000E-04 263.0 811 7.4000E-04 276.9 811 1.0200E-03 287.5 811 1.6500E-03 299.8 811 2.6500E-03 310.1 811 3.6400E-03 317.1 811 4.5400E-03 322.0 811 5.5900E-03 326.8 811 6.5700E-03 330.9 811 7.5700E-03 334.6 811 8.4800E-03 337.8 811 1.8490E-02 358.8 811 2.8450E-02 371.5 811 3.8510E-02 379.3 811 4.8410E-02 384.2 811 5.8460E-02 387.3
B-13 T [K]
True plastic strain [mm/mm]
True stress [MPa]
811 6.8450E-02 389.4 811 7.8490E-02 390.7 811 8.8550E-02 391.6 900 0.0000E+00 115.4 900 5.6000E-03 155.1 900 1.4200E-02 168.1 900 2.5500E-02 177.2 900 3.9900E-02 182.2 900 5.5000E-02 182.1 900 6.4800E-02 185.1 1050 0.0000E+00 57.1 1050 7.0000E-03 66.0 1050 1.5000E-02 70.8 1050 2.8000E-02 74.4 1050 4.1000E-02 76.5 1050 5.8000E-02 78.1 1050 7.6000E-02 81.2 1050 8.8000E-02 82.8 1150 0.0000E+00 36.2 1150 5.0000E-03 40.9 1150 1.6000E-02 44.0 1150 2.9000E-02 46.1 1150 5.0000E-02 47.2 1150 7.9000E-02 49.8 1250 0.0000E+00 21.5 1250 1.1000E-02 24.6 1250 2.5000E-02 28.8 1250 5.3000E-02 30.9 1250 8.4000E-02 32.0 1373 0.0000E+00 10.0 1373 1.0000E-02 14.2
B-14 T [K]
True plastic strain [mm/mm]
True stress [MPa]
1373 3.0000E-02 16.2 1373 7.2000E-02 17.8 1373 1.3500E-01 18.9 1373 1.7300E-01 21.0 1473 0.0000E+00 5.0 Table B-9 Elastic Properties - Low Alloy Steel T [K]
E [MPa]
294.1 201330 0.300 366.3 196510 0.300 421.9 193060 0.300 477.4 188920 0.300 533.0 186170 0.300 588.6 182030 0.300 644.1 174440 0.300 699.7 164790 0.300 755.2 153070 0.300 1033.0 100250 0.300 1073.0 20000 0.300 1273.0 6000 0.300
B-15 Table B-10 Thermal Expansion - Low Alloy Steel (Reference T0=293 K)
T [K]
CTE [K-1]
310.8 1.1700E-05 338.6 1.1826E-05 366.3 1.2006E-05 394.1 1.2186E-05 421.9 1.2366E-05 449.7 1.2564E-05 477.4 1.2726E-05 505.2 1.2870E-05 533.0 1.3050E-05 560.8 1.3212E-05 588.6 1.3356E-05 616.3 1.3536E-05 644.1 1.3662E-05 671.9 1.3824E-05 699.7 1.3968E-05 973.0 1.4700E-05 1073.0 1.6900E-05 1273.0 1.6900E-05 1278.0 1.7000E-05 2273.0 2.0200E-05 Table B-11 Creep Law - Low Alloy Steel T [K]
A [MPan/s]
n m
293 4.42500E-50 4
0 673 4.42500E-40 4
0 850 5.42972E-21 6.0451 0
894 7.25111E-15 4.8865 0
1644.1 2.61E-11 4.8865 0
B-16 Table B-12 Thermal Conductivity - Low Alloy Steel T [K]
Thermal Conductivity
[W/(mm-K)]
273 5.95E-02 373 5.78E-02 473 5.32E-02 573 4.94E-02 673 4.56E-02 773 4.10E-02 873 3.68E-02 973 3.31E-02 1073 2.85E-02 1273 2.76E-02 1473 2.97E-02 2000 6.50E-02
B-17 Table B-13 Specific Heat - Low Alloy Steel T [K]
Specific Heat
[J/(g-K)]
348 0.418 448 0.519 498 0.536 548 0.553 598 0.574 648 0.595 748 0.662 848 0.754 948 0.867 998 1.2 1048 0.875 1148 0.846 1185 0.605 1600 0.735 1800 0.835 Table B-14 Miscellaneous Properties - Low Alloy Steel Density
[g/mm3]
Latent Heat
[J/g]
Solidus
[K]
Liquidus
[K]
Anneal Temperature [K]
7.80E-03 272.0 1500 1600 1474 Table B-15 Isotropic Hardening - Stainless Steel T [K]
True plastic stress [MPa]
True strain [mm/mm]
294 0.00E+00 241.3 294 1.00E-02 289.6 294 5.00E-02 393.0 294 1.00E-01 482.6 294 2.00E-01 620.5
B-18 T [K]
True plastic stress [MPa]
True strain [mm/mm]
294 4.00E-01 827.4 693 0.00E+00 117.2 693 1.00E-02 193.1 693 5.00E-02 275.8 693 1.00E-01 358.5 693 2.00E-01 482.6 693 4.00E-01 620.5 693 8.00E-01 724.0 923 0.00E+00 96.5 923 1.00E-02 144.8 923 5.00E-02 213.7 923 1.00E-01 282.7 923 2.00E-01 379.2 923 4.00E-01 448.2 923 8.00E-01 482.6 1089 0.00E+00 68.9 1089 1.00E-02 110.3 1089 5.00E-02 144.8 1089 1.00E-01 172.4 1089 2.00E-01 206.8 1089 4.00E-01 241.3 1089 8.00E-01 241.3 1366 0.00E+00 27.6 1366 1.00E-02 38.6 1366 5.00E-02 41.4 1366 1.00E-01 41.4 1366 2.00E-01 41.4 1366 4.00E-01 41.4 1366 8.00E-01 41.4 1550 0.00E+00 5.0
B-19 Table B-16 Elastic Properties - Stainless Steel T [K]
E [MPa]
294.1 195130 0.267 366.3 190300 0.273 421.9 186170 0.290 477.4 182720 0.310 533.0 177890 0.322 588.6 174440 0.313 644.1 171000 0.296 699.7 166170 0.282 755.2 162030 0.262 866.3 153060 0.240 977.4 143550 0.229 1088.6 131690 0.223 1173.0 116520 0.223 1273.0 99974 0.223 1373.0 80000 0.223 1473.0 57000 0.223 1573.0 30000 0.223 1673.0 2000 0.223
B-20 Table B-17 Thermal Expansion - Stainless Steel (Reference T0=293 K)
T [K]
CTE [MPa]
310.8 1.5372E-05 338.6 1.5552E-05 366.3 1.5768E-05 394.1 1.5984E-05 421.9 1.6146E-05 449.7 1.6398E-05 477.4 1.6578E-05 505.2 1.6776E-05 533.0 1.6956E-05 560.8 1.7100E-05 588.6 1.7280E-05 616.3 1.7442E-05 644.1 1.7568E-05 671.9 1.7658E-05 699.7 1.7820E-05 873.0 1.8210E-05 973.0 1.8540E-05 1073.0 1.8830E-05 1173.0 1.9110E-05 1273.0 1.9380E-05 1373.0 1.9660E-05 1473.0 1.9950E-05 1693.0 2.0700E-05 1733.0 2.0700E-05
B-21 Table B-18 Creep Law - Stainless Steel T [K]
A [MPan/s]
n m
293 1.22903E-40 4
0 748 1.62061E-36 9.78 0
773 5.68439E-36 9.97 0
798 1.15262E-32 9.06 0
823 1.46763E-29 8.2 0
848 1.01784E-28 8.2 0
873 6.30514E-28 8.2 0
898 4.49442E-27 8.18 0
923 2.88186E-26 8.16 0
948 5.68400E-24 7.42 0
973 8.56247E-22 6.72 0
998 3.33908E-20 6.25 0
1023 1.30224E-18 5.77 0
Table B-19 Thermal Conductivity - Stainless Steel T [K]
Thermal Conductivity
[W/(mm-K)]
300 1.33824E-02 700 2.09100E-02 1200 3.34560E-02 2000 8.00000E-02
B-22 Table B-20 Specific Heat - Stainless Steel T [K]
Specific Heat
[J/(g-K)]
360 3.433176E-01 700 4.856688E-01 870 5.359104E-01 925 5.442840E-01 1300 5.526576E-01 Table B-21 Miscellaneous Properties - Stainless Steel Density
[g/mm3]
Latent Heat
[J/g]
Solidus
[K]
Liquidus
[K]
Anneal Temperature [K]
7.90E-03 40.0 1560 1630 1551 225.0 1630 1670
C-1 DATA FOR VALIDATION PROCESS This appendix contains the tabular data referenced in Section 5.5. This data is necessary to execute the recommended validation procedure. Table C-1 shows the mean weld residual stress (WRS) profiles from the average hardening predictions in the Phase 2b dataset. The mean chosen here is the cross-section mean (see [13] for a detailed description of determining means of functional data).
Table C-1 Mean of the Average Hardening WRS Predictions r/t Axial Mean WRS [MPa]
Hoop Mean WRS [MPa]
0.0000
-165
-28 0.0101
-159
-18 0.0202
-154
-8 0.0303
-150 1
0.0404
-146 9
0.0505
-142 16 0.0606
-139 23 0.0707
-134 29 0.0808
-130 34 0.0909
-126 40 0.1010
-121 45 0.1111
-117 50 0.1212
-114 55 0.1313
-110 61 0.1414
-108 67 0.1515
-106 73 0.1616
-104 79 0.1717
-103 84 0.1818
-102 90 0.1919
-101 95 0.2020
-99 98 0.2121
-97 101 0.2222
-95 103 0.2323
-93 103 APPENDIX C
C-2 r/t Axial Mean WRS [MPa]
Hoop Mean WRS [MPa]
0.2424
-90 104 0.2525
-88 103 0.2626
-86 103 0.2727
-85 102 0.2828
-84 101 0.2929
-85 101 0.3030
-86 101 0.3131
-89 101 0.3232
-93 100 0.3333
-98 98 0.3434
-105 94 0.3535
-112 89 0.3636
-121 82 0.3737
-132 74 0.3838
-143 63 0.3939
-154 51 0.4040
-166 39 0.4141
-177 25 0.4242
-188 10 0.4343
-198
-5 0.4444
-206
-20 0.4545
-213
-35 0.4646
-219
-49 0.4747
-223
-63 0.4848
-225
-75 0.4949
-226
-87 0.5051
-226
-96 0.5152
-223
-104 0.5253
-219
-109 0.5354
-214
-113 0.5455
-207
-115
C-3 r/t Axial Mean WRS [MPa]
Hoop Mean WRS [MPa]
0.5556
-199
-115 0.5657
-190
-113 0.5758
-180
-110 0.5859
-169
-105 0.5960
-157
-98 0.6061
-144
-90 0.6162
-130
-80 0.6263
-115
-70 0.6364
-99
-58 0.6465
-83
-46 0.6566
-65
-33 0.6667
-47
-19 0.6768
-28
-4 0.6869
-9 10 0.6970 11 24 0.7071 30 38 0.7172 49 52 0.7273 68 64 0.7374 87 76 0.7475 105 86 0.7576 123 96 0.7677 140 105 0.7778 158 113 0.7879 176 121 0.7980 194 129 0.8081 213 137 0.8182 233 144 0.8283 252 151 0.8384 271 157 0.8485 289 163 0.8586 306 167
C-4 r/t Axial Mean WRS [MPa]
Hoop Mean WRS [MPa]
0.8687 321 170 0.8788 334 171 0.8889 343 171 0.8990 351 169 0.9091 356 166 0.9192 360 163 0.9293 362 159 0.9394 363 155 0.9495 363 151 0.9596 362 149 0.9697 361 147 0.9798 359 145 0.9899 357 144 1.0000 355 143
D-1 ANALYSIS OF VALIDATION METRICS FOR AVERAGE HARDENING This appendix describes analyses performed to explore potential additional or alternative metrics for weld residual stress (WRS) validation, in complement to those presented in Section 5.4.7.
D.1 Root Mean Square Error on First Derivative D.1.1 Definition for RMSED1 The first additional quality metric is RMSE on the first derivative of WRS with respect to through-wall position. This quality metric is related to through-wall WRS trends and concavity. Here, the three-point formula was used to estimate the first derivative [20],[35].
1=
1 2 (+1 1) where t
r xnorm =
is the through-wall position normalized to the wall thickness and h is the distance between the kth and k+1th data point (h should not vary from interval to interval), and WRSk is the analysts predicted stress magnitude at the kth position through the wall thickness.
The RMSE on first derivative was calculated according to:
1 =
1 2 (11
)
1
=2 where L is the number of equally-spaced points chosen to represent the WRS profile through the wall thickness (from x/t = 0 to x/t = 1), D1k is the first derivative of the analysts predicted stress magnitude at the kth position through the wall thickness, and D1kmean is the first derivative of the cross-sectional mean prediction.
D.1.2 Results and Assessment for RMSED1 RMSED1 was calculated for both axial and hoop WRS, as shown in Figure D-1. The acceptance criterion for RMSED1 was set to RMSED1<520 for axial WRS, and to RMSED1<550 for hoop WRS.
These values were chosen such that all the participants whose WRS prediction resulted in acceptable crack growth passed the criterion for the RMSED2 metric. In Figure D-1, the cells highlighted in green on the left-side tables meet the corresponding acceptance measures shown in the tables on the right.
For axial WRS, the acceptance criterion that had to be set for RMSED1 does not allow for a distinction to be made between the WRS predictions that resulted in acceptable crack growth (hereafter referred to as good predictions) and those that did not (hereafter referred to as bad predictions). In fact, all except two of the participants meet the acceptance criterion for the RMSED1 metric, because participant G, who predicted similar crack growth, had the third highest RMSED1 of all participants.
APPENDIX D
D-2 For hoop WRS, similarly, the acceptance criterion that had to be set for RMSED1 does not allow for a distinction to be made between the WRS predictions that resulted in acceptable crack growth and those that did not. In fact, all except two of the participants meet the acceptance criterion for the RMSED1 metric, because participant G, who predicted similar crack growth, had the third highest RMSED1 of all participants.
In summary, there is no added benefit to using the RMSED1 metric, since it is not able to distinguish well between the good and the bad WRS predictions without also using the diffave metric, which was already the case when using the RMSEWRS metric.
Figure D-1 Quality metrics for Phase 2b average predictions, including RMSED1. (left),
and acceptance measures for the proposed metrics (right).
D1 Participant RMSE WRS RMSE D1 diff avg Crack Growth D
29 409
-10 Acceptable Metric Acceptance E
32 366 11 Acceptable RMSE WRS
55 G
52 512 14 Acceptable RMSE D1
520 B
79 523 92 Not Acceptable diff avg
15 A
59 374
-55 Not Acceptable diff avg
-15 C
28 300
-31 Not Acceptable F
46 624
-20 Not Acceptable Min 28 300
-55 25th percentile 30 370
-26 Median 46 409
-10 75th percentile 56 518 12 Max 79 624 92 D1 Participant RMSE WRS RMSE D1 diff avg Time to leakage D
49 417 47 Acceptable Metric Acceptance E
26 330 13 Acceptable RMSE WRS
70 G
68 525 63 Acceptable RMSE D1
550 B
74 717 114 Not Acceptable diff avg
0 A
51 524
-37 Not Acceptable diff avg
65 C
34 331
-56 Not Acceptable F
50 591
-30 Not Acceptable Min 26 330
-56 25th percentile 42 374
-33 Median 50 524 13 75th percentile 60 558 55 Max 74 717 114 Axial Stress / Circ Flaw Growth Axial WRS Hoop Stress / Axial Flaw Growth Hoop WRS
D-3 D.2 Root Mean Square Error on Second Derivative D.2.1 Definition for RMSED2 The second additional metric investigated was root mean square error (RMSE) on the second derivative of WRS with respect to through-wall position. This quality metric is related to through-wall WRS trends and is a true measure of concavity.
2=
1
1 4 2 (+2 2 + 2) where t
r xnorm =
is the through-wall position normalized to the wall thickness, h is the distance between the kth and k+1th data point (h should not vary from interval to interval), and WRSk is the analysts predicted stress magnitude at the kth position through the wall thickness.
The RMSE on the second derivative was calculated according to:
2 =
1 4 (22
)
2
=3 where L is the number of equally-spaced points chosen to represent the WRS profile through the wall thickness (from x/t = 0 to x/t = 1), D2k is the second derivative of the analysts predicted stress magnitude at the kth position through the wall thickness, and D2kmean is the second derivative of the cross-sectional mean prediction.
D.2.2 Results and Assessment for RMSED2 RMSED2 was calculated for both axial and hoop WRS, as shown in Figure D-2. The acceptance criterion for RMSED2 was set to RMSED2<10,050 for axial WRS, and to RMSED2<11,000 for hoop WRS. These values were chosen such that all the participants whose WRS prediction resulted in acceptable crack growth passed the criterion for the RMSED2 metric. In Figure D-2, the cells highlighted in green on the left-side tables meet the corresponding acceptance measures shown in the tables on the right.
For axial WRS, the acceptance criterion that had to be set for RMSED2 does not allow for a distinction to be made between the WRS predictions that resulted in acceptable crack growth (hereafter referred to as good predictions) and those that did not (hereafter referred to as bad predictions). In fact, all except one of the participants meet the acceptance criterion for the RMSED2 metric, because participant G, who predicted similar crack growth, had the second highest RMSED2 of all participants.
For hoop WRS, in all cases except for participant C, the acceptance criterion that had to be set for RMSED2 allows for a distinction between the WRS predictions that resulted in acceptable time to leakage (hereafter referred to as good predictions) and those that did not (hereafter referred to as bad predictions).
D-4 In summary, there is no added benefit to using the RMSED2 metric, since it is not able to distinguish between the good and the bad WRS predictions without also using the diffave metric, which was already the case when using the RMSEWRS and RMSED1 metrics.
Figure D-2 Quality metrics for Phase 2b average predictions, including RMSED2. (left),
and acceptance measures for the proposed metrics (right).
D2 Participant RMSE WRS RMSE D1 RMSE D2 diff avg Crack Growth D
29 409 8130
-10 Acceptable Metric Acceptance E
32 366 6458 11 Acceptable RMSE WRS
55 G
52 512 10025 14 Acceptable RMSE D1
520 B
79 523 9207 92 Not Acceptable RMSE D2
10050 A
59 374 5882
-55 Not Acceptable diff avg
15 C
28 300 6414
-31 Not Acceptable diff avg
-15 F
46 624 12475
-20 Not Acceptable Min 28 300 5882
-55 25th percentile 30 370 6436
-26 Median 46 409 8130
-10 75th percentile 56 518 9616 12 Max 79 624 12475 92 D2 Participant RMSE WRS RMSE D1 RMSE D2 diff avg Time to leakage D
49 417 8569 47 Acceptable Metric Acceptance E
26 330 5583 13 Acceptable RMSE WRS
70 G
68 525 10951 63 Acceptable RMSE D1
550 B
74 717 14028 114 Not Acceptable RMSE D2
11000 A
51 524 15332
-37 Not Acceptable diff avg
0 C
34 331 7421
-56 Not Acceptable diff avg
65 F
50 591 13245
-30 Not Acceptable Min 26 330 5583
-56 25th percentile 42 374 7995
-33 Median 50 524 10951 13 75th percentile 60 558 13636 55 Max 74 717 15332 114 Hoop WRS Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Axial WRS
D-5 D.3 Truncated Metrics D.3.1 Definitions for Truncated Metrics Truncated RMSEWRS and RMSED1 metrics were investigated to determine if a truncation limit for the calculation of RMSE would improve the ability to distinguish between the good and bad WRS predictions. The following equations define (RMSEWRS)T and (RMSED1)T.
()= 1
(
)
1 (1)
1 1 (11
)
=2 where LT is the number of equally-spaced points where WRS or D1 are known, up to the truncation limit T, with 0<T<1. For example, for T=0.55, if there are 100 equally-spaced points through the wall thickness where WRS and D1 are known, LT would be equal to 55. WRSk and D1k are the WRS and first derivative of the WRS at the kth position through the wall thickness, and WRSkmean and D1kmean are the WRS and first derivative of the cross-sectional mean prediction.
(RMSEWRS)T and (RMSED1)T were calculated for T=0.1, 0.2,, 0.9, as shown in D.3.2. In addition, (RMSEWRS)T and (RMSED1)T were calculated for T=a/t(10 years) and T=a/t(20 years), as shown in Section D.3.3 and Section D.3.4, respectively.
D.3.2 Assessment of Arbitrary Truncation Figure D-3 through Figure D-11 show the results for the analysis of truncated metrics (RMSEWRS)T and (RMSED1)T for T=0.1, 0.2,, 0.9. As in previous figures, the cells highlighted in green on the left-side tables meet the corresponding acceptance measures shown in the tables on the right. In addition, the cells with green text and green background in the tables on the right (showing the acceptance measures) indicate the cases where the acceptance measures could be narrowed as compared to the criteria in Sections 5.4.9 and 5.4.11. These are the cases where using the truncated metrics results in a better ability to distinguish between good and bad WRS predictions.
Below each figure in this section, a case-by-case assessment is provided. Overall, the truncated metrics do not offer any clear improvement over the basic metrics proposed in this report (see Sections 5.4.8 and 5.4.10).
D-6 Figure D-3 Truncated Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.1 Assessment of truncated metrics for T=0.1:
Acceptance measures:
o Narrower (improved) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall no improvement in acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 T=0.1 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
10 278
-10 Acceptable Metric Acceptance E
28 890 11 Acceptable (RMSE WRS ) T
30 G
17 553 14 Acceptable (RMSE D1 ) T
900 B
93 397 92 Not Acceptable diff avg
15 A
56 141
-55 Not Acceptable diff avg
-15 C
31 64
-31 Not Acceptable F
49 1517
-20 Not Acceptable Min 10 64
-55 25th percentile 22 209
-26 Median 31 397
-10 75th percentile 52 722 12 Max 93 1517 92 T=0.1 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
48 412 47 Acceptable Metric Acceptance E
19 544 13 Acceptable (RMSE WRS ) T
65 G
64 899 63 Acceptable (RMSE D1 ) T
900 B
117 667 114 Not Acceptable diff avg
0 A
36 374
-37 Not Acceptable diff avg
65 C
57 211
-56 Not Acceptable F
52 1508
-30 Not Acceptable Min 19 211
-55 25th percentile 42 393
-26 Median 52 544
-10 75th percentile 61 783 12 Max 117 1508 92 Axial WRS Hoop WRS Hoop Stress / Axial Flaw Growth Axial Stress / Circ Flaw Growth
D-7 Figure D-4 Truncated Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.2 Assessment of truncated metrics for T=0.2:
Acceptance measures:
o Identical (RMSEWRS)T acceptance criterion for axial WRS o Wider (worse) (RMSEWRS)T acceptance criterion for hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 T=0.2 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
27 285
-10 Acceptable Metric Acceptance E
42 655 11 Acceptable (RMSE WRS ) T
55 G
51 518 14 Acceptable (RMSE D1 ) T
675 B
85 336 92 Not Acceptable diff avg
15 A
54 110
-55 Not Acceptable diff avg
-15 C
29 91
-31 Not Acceptable F
68 1050
-20 Not Acceptable Min 27 91
-55 25th percentile 35 197
-26 Median 51 336
-10 75th percentile 61 587 12 Max 85 1050 92 T=0.2 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
38 394 47 Acceptable Metric Acceptance E
35 411 13 Acceptable (RMSE WRS ) T
100 G
97 665 63 Acceptable (RMSE D1 ) T
675 B
94 648 114 Not Acceptable diff avg
0 A
45 461
-37 Not Acceptable diff avg
65 C
49 205
-56 Not Acceptable F
80 1065
-30 Not Acceptable Min 35 205
-55 25th percentile 41 403
-26 Median 49 461
-10 75th percentile 87 657 12 Max 97 1065 92 Axial WRS Hoop WRS Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth
D-8 Figure D-5 Truncated Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.3 Assessment of truncated metrics for T=0.3:
Acceptance measures:
o Wider (worse) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 T=0.3 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
24 329
-10 Acceptable Metric Acceptance E
41 541 11 Acceptable (RMSE WRS ) T
60 G
56 464 14 Acceptable (RMSE D1 ) T
550 B
78 369 92 Not Acceptable diff avg
15 A
62 226
-55 Not Acceptable diff avg
-15 C
31 167
-31 Not Acceptable F
63 969
-20 Not Acceptable Min 24 167
-55 25th percentile 36 277
-26 Median 56 369
-10 75th percentile 62 502 12 Max 78 969 92 T=0.3 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
35 361 47 Acceptable Metric Acceptance E
34 371 13 Acceptable (RMSE WRS ) T
100 G
98 615 63 Acceptable (RMSE D1 ) T
620 B
79 651 114 Not Acceptable diff avg
0 A
45 461
-37 Not Acceptable diff avg
65 C
42 233
-56 Not Acceptable F
85 939
-30 Not Acceptable Min 34 233
-55 25th percentile 38 366
-26 Median 45 461
-10 75th percentile 82 633 12 Max 98 939 92 Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Axial WRS Hoop WRS
D-9 Figure D-6 Truncated Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.4 Assessment of truncated metrics for T=0.4:
Acceptance measures:
o Identical (RMSEWRS)T acceptance criterion for axial WRS o Wider (worse) (RMSEWRS)T acceptance criterion for hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 T=0.4 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
29 390
-10 Acceptable Metric Acceptance E
41 510 11 Acceptable (RMSE WRS ) T
55 G
51 598 14 Acceptable (RMSE D1 ) T
600 B
69 391 92 Not Acceptable diff avg
15 A
68 301
-55 Not Acceptable diff avg
-15 C
31 288
-31 Not Acceptable F
55 876
-20 Not Acceptable Min 29 288
-55 25th percentile 36 345
-26 Median 51 391
-10 75th percentile 61 554 12 Max 69 876 92 T=0.4 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
43 401 47 Acceptable Metric Acceptance E
30 390 13 Acceptable (RMSE WRS ) T
90 G
88 595 63 Acceptable (RMSE D1 ) T
600 B
69 631 114 Not Acceptable diff avg
0 A
51 476
-37 Not Acceptable diff avg
65 C
36 281
-56 Not Acceptable F
76 844
-30 Not Acceptable Min 30 281
-55 25th percentile 40 395
-26 Median 51 476
-10 75th percentile 72 613 12 Max 88 844 92 Hoop Stress / Axial Flaw Growth Hoop WRS Axial Stress / Circ Flaw Growth Axial WRS
D-10 Figure D-7 Truncated Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.5 Assessment of truncated metrics for T=0.5:
Acceptance measures:
o Identical (RMSEWRS)T acceptance criterion for axial WRS o Wider (worse) (RMSEWRS)T acceptance criterion for hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 T=0.5 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
34 409
-10 Acceptable Metric Acceptance E
37 487 11 Acceptable (RMSE WRS ) T
55 G
54 570 14 Acceptable (RMSE D1 ) T
575 B
67 400 92 Not Acceptable diff avg
15 A
62 398
-55 Not Acceptable diff avg
-15 C
29 301
-31 Not Acceptable F
51 806
-20 Not Acceptable Min 29 301
-55 25th percentile 36 399
-26 Median 51 409
-10 75th percentile 58 528 12 Max 67 806 92 T=0.5 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
58 407 47 Acceptable Metric Acceptance E
29 373 13 Acceptable (RMSE WRS ) T
80 G
79 567 63 Acceptable (RMSE D1 ) T
575 B
70 693 114 Not Acceptable diff avg
0 A
63 521
-37 Not Acceptable diff avg
65 C
38 308
-56 Not Acceptable F
68 765
-30 Not Acceptable Min 29 308
-55 25th percentile 48 390
-26 Median 63 521
-10 75th percentile 69 630 12 Max 79 765 92 Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Hoop WRS Axial WRS
D-11 Figure D-8 Truncated Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.6 Assessment of truncated metrics for T=0.6:
Acceptance measures:
o Wider (worse) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial WRS o Narrower (improved) (RMSED1)T acceptance criterion for hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 T=0.6 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
32 407
-10 Acceptable Metric Acceptance E
35 444 11 Acceptable (RMSE WRS ) T
60 G
57 526 14 Acceptable (RMSE D1 ) T
550 B
67 386 92 Not Acceptable diff avg
15 A
58 403
-55 Not Acceptable diff avg
-15 C
27 286
-31 Not Acceptable F
47 748
-20 Not Acceptable Min 27 286
-55 25th percentile 33 395
-26 Median 47 407
-10 75th percentile 58 485 12 Max 67 748 92 T=0.6 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
56 438 47 Acceptable Metric Acceptance E
27 361 13 Acceptable (RMSE WRS ) T
75 G
73 518 63 Acceptable (RMSE D1 ) T
525 B
84 661 114 Not Acceptable diff avg
0 A
59 514
-37 Not Acceptable diff avg
65 C
35 385
-56 Not Acceptable F
63 718
-30 Not Acceptable Min 27 361
-55 25th percentile 46 411
-26 Median 59 514
-10 75th percentile 68 589 12 Max 84 718 92 Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Axial WRS Hoop WRS
D-12 Figure D-9 Truncated Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.7 Assessment of truncated metrics for T=0.7:
Acceptance measures:
o Wider (worse) (RMSEWRS)T acceptance criterion for axial WRS o Identical (RMSEWRS)T acceptance criterion for hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial WRS o Identical (RMSED1)T acceptance criterion for hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 T=0.7 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
30 389
-10 Acceptable Metric Acceptance E
33 415 11 Acceptable (RMSE WRS ) T
60 G
59 530 14 Acceptable (RMSE D1 ) T
550 B
64 565 92 Not Acceptable diff avg
15 A
59 382
-55 Not Acceptable diff avg
-15 C
25 282
-31 Not Acceptable F
44 701
-20 Not Acceptable Min 25 282
-55 25th percentile 31 386
-26 Median 44 415
-10 75th percentile 59 548 12 Max 64 701 92 T=0.7 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
54 411 47 Acceptable Metric Acceptance E
26 357 13 Acceptable (RMSE WRS ) T
70 G
68 526 63 Acceptable (RMSE D1 ) T
550 B
85 741 114 Not Acceptable diff avg
0 A
56 477
-37 Not Acceptable diff avg
65 C
36 365
-56 Not Acceptable F
58 664
-30 Not Acceptable Min 26 357
-55 25th percentile 45 388
-26 Median 56 477
-10 75th percentile 63 595 12 Max 85 741 92 Hoop WRS Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Axial WRS
D-13 Figure D-10 Truncated Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.8 Assessment of truncated metrics for T=0.8:
Acceptance measures:
o Wider (worse) (RMSEWRS)T acceptance criterion for axial WRS o Identical (RMSEWRS)T acceptance criterion for hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial WRS o Narrower (better) (RMSED1)T acceptance criterion for hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 T=0.8 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
29 402
-10 Acceptable Metric Acceptance E
33 389 11 Acceptable (RMSE WRS ) T
60 G
55 518 14 Acceptable (RMSE D1 ) T
525 B
69 572 92 Not Acceptable diff avg
15 A
62 364
-55 Not Acceptable diff avg
-15 C
28 290
-31 Not Acceptable F
43 660
-20 Not Acceptable Min 28 290
-55 25th percentile 31 377
-26 Median 43 402
-10 75th percentile 59 545 12 Max 69 660 92 T=0.8 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
51 446 47 Acceptable Metric Acceptance E
26 348 13 Acceptable (RMSE WRS ) T
70 G
66 508 63 Acceptable (RMSE D1 ) T
510 B
80 716 114 Not Acceptable diff avg
0 A
53 551
-37 Not Acceptable diff avg
65 C
35 349
-56 Not Acceptable F
55 640
-30 Not Acceptable Min 26 348
-55 25th percentile 43 397
-26 Median 53 508
-10 75th percentile 61 596 12 Max 80 716 92 Axial WRS Hoop WRS Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth
D-14 Figure D-11 Truncated Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.9 Assessment of truncated metrics for T=0.9:
Acceptance measures:
o Identical (RMSEWRS)T acceptance criterion for axial and hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial WRS o Narrower (better) (RMSED1)T acceptance criterion for hoop WRS o Overall similar acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 D.3.3 Assessment of Truncation at 10 Years Crack Growth Figure D-12 shows the results for the analysis of truncated metrics (RMSEWRS)T and (RMSED1)T for T=a/t(10 years), which vary by participant. As in previous figures, the cells highlighted in green T=0.9 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
30 400
-10 Acceptable Metric Acceptance E
34 370 11 Acceptable (RMSE WRS ) T
55 G
54 528 14 Acceptable (RMSE D1 ) T
530 B
76 541 92 Not Acceptable diff avg
15 A
62 390
-55 Not Acceptable diff avg
-15 C
29 310
-31 Not Acceptable F
47 635
-20 Not Acceptable Min 29 310
-55 25th percentile 32 380
-26 Median 47 400
-10 75th percentile 58 535 12 Max 76 635 92 T=0.9 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
51 430 47 Acceptable Metric Acceptance E
27 335 13 Acceptable (RMSE WRS ) T
70 G
69 510 63 Acceptable (RMSE D1 ) T
515 B
77 695 114 Not Acceptable diff avg
0 A
54 542
-37 Not Acceptable diff avg
65 C
35 339
-56 Not Acceptable F
53 617
-30 Not Acceptable Min 27 335
-55 25th percentile 43 384
-26 Median 53 510
-10 75th percentile 61 579 12 Max 77 695 92 Axial WRS Hoop WRS Hoop Stress / Axial Flaw Growth Axial Stress / Circ Flaw Growth
D-15 on the left-side tables meet the corresponding acceptance measures shown in the tables on the right. In addition, the cells with green text and green background in the right-side tables (showing the acceptance measures) indicate the cases where the acceptance measures could be narrowed as compared to the criteria presented in Sections 5.4.9 and 5.4.11. These are the cases where using the truncated metrics results in a better ability to distinguish between good and bad WRS predictions.
Figure D-12 Truncated Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=a/t(10 years)
Assessment of truncated metrics for T=a/t(10 years):
Acceptance measures:
o Identical (RMSEWRS)T acceptance criterion for axial and hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial WRS o Narrower (better) (RMSED1)T acceptance criterion for hoop WRS o Overall similar acceptance measures Ability to distinguish between good and bad predictions:
T = a/t (10 yrs)
Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
22 311
-10 Acceptable Metric Acceptance E
38 496 11 Acceptable (RMSE WRS ) T
55 G
52 594 14 Acceptable (RMSE D1 ) T
600 B
79 520 92 Not Acceptable diff avg
15 A
56 141
-55 Not Acceptable diff avg
-15 C
31 59
-31 Not Acceptable F
52 1442
-20 Not Acceptable Min 22 59
-55 25th percentile 34 226
-26 Median 52 496
-10 75th percentile 54 557 12 Max 79 1442 92 T = a/t (10 yrs)
Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
49 415 47 Acceptable Metric Acceptance E
27 352 13 Acceptable (RMSE WRS ) T
70 G
68 522 63 Acceptable (RMSE D1 ) T
525 B
74 713 114 Not Acceptable diff avg
0 A
48 432
-37 Not Acceptable diff avg
65 C
40 225
-56 Not Acceptable F
86 947
-30 Not Acceptable Min 27 225
-55 25th percentile 44 383
-26 Median 49 432
-10 75th percentile 71 618 12 Max 86 947 92 Axial Stress / Circ Flaw Growth Axial WRS Hoop Stress / Axial Flaw Growth Hoop WRS
D-16 o Similar to basic metrics proposed in 5.4.8 and 5.4.10 Overall, it can be said that truncated metrics with T=a/t(10 years) do not offer any clear improvement over the basic metrics proposed in this report (see 5.4.8 and 5.4.10).
D.3.4 Assessment of Truncation at 20 Years Crack Growth Figure D-13 shows the results for the analysis of truncated metrics (RMSEWRS)T and (RMSED1)T for T=a/t(20 years), which varies by participant. As in previous figures, the cells highlighted in green on the left-side tables meet the corresponding acceptance measures shown in the tables on the right. In addition, the cells with green text and green background in the right-side tables (showing the acceptance measures) indicate the cases where the acceptance measures could be narrowed as compared to the criteria presented in Sections 5.4.9 and 5.4.11. These are the cases where using the truncated metrics results in a better ability to distinguish between good and bad WRS predictions.
D-17 Figure D-13 Truncated Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T= a/t(20 years)
Assessment of truncated metrics for T=a/t(20 years):
Acceptance measures:
o Identical (RMSEWRS)T acceptance criterion for axial and hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial WRS o Narrower (better) (RMSED1)T acceptance criterion for hoop WRS o Overall similar acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 Overall, the truncated metrics with T=a/t(20 years) do not offer any clear improvement over the basic metrics proposed in this report (see Sections 5.4.8 and 5.4.10).
T = a/t (20 yrs)
Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
27 286
-10 Acceptable Metric Acceptance E
33 422 11 Acceptable (RMSE WRS ) T
55 G
54 549 14 Acceptable (RMSE D1 ) T
550 B
79 520 92 Not Acceptable diff avg
15 A
56 141
-55 Not Acceptable diff avg
-15 C
31 63
-31 Not Acceptable F
56 1376
-20 Not Acceptable Min 27 63
-55 25th percentile 32 213
-26 Median 54 422
-10 75th percentile 56 535 12 Max 79 1376 92 T = a/t (20 yrs)
Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
49 415 47 Acceptable Metric Acceptance E
26 329 13 Acceptable (RMSE WRS ) T
70 G
68 522 63 Acceptable (RMSE D1 ) T
525 B
74 713 114 Not Acceptable diff avg
0 A
63 529
-37 Not Acceptable diff avg
65 C
35 384
-56 Not Acceptable F
66 739
-30 Not Acceptable Min 26 329
-55 25th percentile 42 399
-26 Median 63 522
-10 75th percentile 67 621 12 Max 74 739 92 Axial Stress / Circ Flaw Growth Axial WRS Hoop Stress / Axial Flaw Growth Hoop WRS
D-18 D.4 Weighted Metrics D.4.1 Definitions for Weighted Metrics Weighted RMSEWRS and RMSED1 metrics were investigated to determine if a weight function for the calculation of RMSE would improve the ability to distinguish between the good and bad WRS predictions. The following equations define (RMSEWRS)W and (RMSED1)W:
()= 1 1
(
)
1 (1)
1 2 1
(11
)
1
=2 where L is the number of equally-spaced points chosen to represent the WRS profile through the wall thickness (from x/t = 0 to x/t = 1), W is the weight exponent, xk/t is the normalized through-thickness distance at the kth position through the wall thickness, WRSk and D1k are the WRS and first derivative of the WRS at the kth position through the wall thickness, and WRSkmean and D1kmean are the WRS and first derivative of the cross-sectional mean prediction.
(RMSEWRS)W and (RMSED1)W were calculated for W=1, 2, 5, 10, as shown in Section D.4.2. The weight function gives higher weight to values of (WRSk-WRSkmean) or (D1k-D1kmean) closer to x/t = 0. Furthermore, as the weight exponent increases, the weight function eventually takes values smaller than 1%, essentially truncating the RMSE calculation beyond a certain point, as illustrated in Figure D-14.
Figure D-14 Weight Function as a Function of Weight Exponent W
D-19 D.4.2 Results and Assessment for Weighted Metrics Figure D-15 though Figure D-18 show the results for the analysis of weighted metrics (RMSEWRS)W and (RMSED1)W for W=1, 2, 5, and 10. As in previous figures, the cells highlighted in green on the left-side tables meet the corresponding acceptance measures shown in the tables on the right. In addition, the cells with green text and green background in the right-side tables (showing the acceptance measures) indicate the cases where the acceptance measures could be narrowed as compared to the criteria presented in 5.4.9 and 5.4.11. These are the cases where using the weighted metrics results in a better ability to distinguish between good and bad WRS predictions.
Below each figure in this section, a case-by-case assessment is provided. Overall, weighted metrics allow for a significant narrowing of the acceptance measures for both axial and hoop WRS, which is an improvement over the basic metrics proposed in Sections 5.4.8 and 5.4.10.
However, since the ability to distinguish between good and bad predictions is the same as for the basic metrics proposed in this report (see Sections 5.4.8 and 5.4.10), the additional analysis work required to implement weighted metrics is not considered worthwhile.
D-20 Figure D-15 Weighted Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for W=1 Assessment of weighted metrics for W=1:
Acceptance measures:
o Narrower (improved) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Narrower (improved) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall significant improvement in acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 W=1 Weighted Participant (RMSE WRS ) W (RMSE D1 ) W diff avg Crack Growth D
21 277
-10 Acceptable Metric Acceptance E
25 319 11 Acceptable (RMSE WRS ) W
40 G
38 376 14 Acceptable (RMSE D1 ) W
380 B
51 346 92 Not Acceptable diff avg
15 A
43 255
-55 Not Acceptable diff avg
-15 C
20 198
-31 Not Acceptable F
35 543
-20 Not Acceptable Min 20 198
-55 25th percentile 23 266
-26 Median 35 319
-10 75th percentile 41 361 12 Max 51 543 92 W=1 Weighted Participant (RMSE WRS ) W (RMSE D1 ) W diff avg Time to leakage D
36 297 47 Acceptable Metric Acceptance E
20 256 13 Acceptable (RMSE WRS ) W
55 G
53 389 63 Acceptable (RMSE D1 ) W
390 B
57 489 114 Not Acceptable diff avg
0 A
38 359
-37 Not Acceptable diff avg
65 C
26 235
-56 Not Acceptable F
44 524
-30 Not Acceptable Min 20 235
-55 25th percentile 31 277
-26 Median 38 359
-10 75th percentile 48 439 12 Max 57 524 92 Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Axial WRS Hoop WRS
D-21 Figure D-16 Weighted Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for W=2 Assessment of weighted metrics for W=2:
Acceptance measures:
o Narrower (improved) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Narrower (improved) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall significant improvement in acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 W=2 Weighted Participant (RMSE WRS ) W (RMSE D1 ) W diff avg Crack Growth D
17 216
-10 Acceptable Metric Acceptance E
21 296 11 Acceptable (RMSE WRS ) W
35 G
31 308 14 Acceptable (RMSE D1 ) W
310 B
42 254 92 Not Acceptable diff avg
15 A
35 191
-55 Not Acceptable diff avg
-15 C
17 148
-31 Not Acceptable F
31 504
-20 Not Acceptable Min 17 148
-55 25th percentile 19 204
-26 Median 31 254
-10 75th percentile 33 302 12 Max 42 504 92 W=2 Weighted Participant (RMSE WRS ) W (RMSE D1 ) W diff avg Time to leakage D
28 237 47 Acceptable Metric Acceptance E
17 219 13 Acceptable (RMSE WRS ) W
50 G
47 338 63 Acceptable (RMSE D1 ) W
340 B
47 391 114 Not Acceptable diff avg
0 A
31 280
-37 Not Acceptable diff avg
65 C
23 179
-56 Not Acceptable F
40 490
-30 Not Acceptable Min 17 179
-55 25th percentile 26 228
-26 Median 31 280
-10 75th percentile 43 365 12 Max 47 490 92 Axial WRS Hoop WRS Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth
D-22 Figure D-17 Weighted Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for W=5 Assessment of weighted metrics for W=5:
Acceptance measures:
o Narrower (improved) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Narrower (improved) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall significant improvement in acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 W=5 Weighted Participant (RMSE WRS ) W (RMSE D1 ) W diff avg Crack Growth D
10 134
-10 Acceptable Metric Acceptance E
16 256 11 Acceptable (RMSE WRS ) W
20 G
20 212 14 Acceptable (RMSE D1 ) W
260 B
33 156 92 Not Acceptable diff avg
15 A
25 98
-55 Not Acceptable diff avg
-15 C
12 77
-31 Not Acceptable F
24 439
-20 Not Acceptable Min 10 77
-55 25th percentile 14 116
-26 Median 20 156
-10 75th percentile 24 234 12 Max 33 439 92 W=5 Weighted Participant (RMSE WRS ) W (RMSE D1 ) W diff avg Time to leakage D
18 164 47 Acceptable Metric Acceptance E
12 169 13 Acceptable (RMSE WRS ) W
35 G
35 270 63 Acceptable (RMSE D1 ) W
275 B
37 269 114 Not Acceptable diff avg
0 A
19 178
-37 Not Acceptable diff avg
65 C
19 103
-56 Not Acceptable F
30 434
-30 Not Acceptable Min 12 103
-55 25th percentile 18 167
-26 Median 19 178
-10 75th percentile 33 270 12 Max 37 434 92 Axial WRS Hoop WRS Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth
D-23 Figure D-18 Weighted Quality Metrics for Phase 2b Average Predictions (left), and Acceptance measures for the Proposed Metrics (right), for W=10 Assessment of weighted metrics for W=10:
Acceptance measures:
o Narrower (improved) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Narrower (improved) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall significant improvement in acceptance measures Ability to distinguish between good and bad predictions:
o Similar to basic metrics proposed in 5.4.8 and 5.4.10 W=10 Weighted Participant (RMSE WRS ) W (RMSE D1 ) W diff avg Crack Growth D
6 83
-10 Acceptable Metric Acceptance E
11 221 11 Acceptable (RMSE WRS ) W
15 G
12 148 14 Acceptable (RMSE D1 ) W
225 B
26 117 92 Not Acceptable diff avg
15 A
18 49
-55 Not Acceptable diff avg
-15 C
9 35
-31 Not Acceptable F
18 381
-20 Not Acceptable Min 6
35
-55 25th percentile 10 66
-26 Median 12 117
-10 75th percentile 18 185 12 Max 26 381 92 W=10 Weighted Participant (RMSE WRS ) W (RMSE D1 ) W diff avg Time to leakage D
13 126 47 Acceptable Metric Acceptance E
8 136 13 Acceptable (RMSE WRS ) W
25 G
24 220 63 Acceptable (RMSE D1 ) W
225 B
31 198 114 Not Acceptable diff avg
0 A
13 116
-37 Not Acceptable diff avg
65 C
16 67
-56 Not Acceptable F
20 381
-30 Not Acceptable Min 8
67
-55 25th percentile 13 121
-26 Median 16 136
-10 75th percentile 22 209 12 Max 31 381 92 Hoop WRS Axial WRS Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth
E-1 ANALYSIS OF VALIDATION METRICS FOR ISOTROPIC HARDENING This appendix describes analyses performed to explore potential additional or alternative metrics for weld residual stress (WRS) validation when using an isotropic hardening law, in complement to those presented in Section 5.4.7.
E.1 Root Mean Square Error on First Derivative E.1.1 Definition for RMSED1 The first additional quality metric is RMSE on the first derivative of WRS with respect to through-wall position. This quality metric is related to through-wall WRS trends and concavity. Here, the three-point formula was used to estimate the first derivative [20],[35].
1=
1 2 (+1 1) where t
r xnorm =
is the through-wall position normalized to the wall thickness and h is the distance between the kth and k+1th data point (h should not vary from interval to interval), and WRSk is the analysts predicted stress magnitude at the kth position through the wall thickness.
The RMSE on first derivative was calculated according to:
1 =
1 2 (11
)
1
=2 where L is the number of equally-spaced points chosen to represent the WRS profile through the wall thickness (from x/t = 0 to x/t = 1), D1k is the first derivative of the analysts predicted stress magnitude at the kth position through the wall thickness, and D1kmean is the first derivative of the cross-sectional mean prediction.
E.1.2 Results and Assessment for RMSED1 RMSED1 was calculated for both axial and hoop WRS, as shown in Figure D-1. The acceptance criterion for RMSED1 was set to RMSED1<520 for axial WRS, and to RMSED1<550 for hoop WRS.
These values were chosen such that all the participants whose WRS prediction resulted in acceptable crack growth passed the criterion for the RMSED2 metric. In Figure D-1, the cells highlighted in green on the left-side tables meet the corresponding acceptance measures shown in the tables on the right.
For axial WRS, the acceptance criterion that had to be set for RMSED1 does not allow for a distinction to be made between the WRS predictions that resulted in acceptable crack growth (hereafter referred to as good predictions) and those that did not (hereafter referred to as bad predictions). In fact, all except two of the participants meet the acceptance criterion for the APPENDIX E
E-2 RMSED1 metric, because participant G, who predicted similar crack growth, had the third highest RMSED1 of all participants.
For hoop WRS, similarly, the acceptance criterion that had to be set for RMSED1 does not allow for a distinction to be made between the WRS predictions that resulted in acceptable crack growth and those that did not. In fact, all except two of the participants meet the acceptance criterion for the RMSED1 metric, because participant G, who predicted similar crack growth, had the third highest RMSED1 of all participants.
In summary, there is no added benefit to using the RMSED1 metric, since it is not able to distinguish well between the good and the bad WRS predictions without also using the diffave metric, which was already the case when using the RMSEWRS metric.
Figure E-1 Quality metrics for Phase 2b average predictions, including RMSED1. (left),
and acceptance measures for the proposed metrics (right).
D1 Participant RMSE WRS RMSE D1 diff avg Crack Growth D
52 768 8 Similar Metric Acceptance E
48 660 22 Similar RMSE WRS
75 G
74 865
-1 Similar RMSE D1
900 B
109 839 120 Too Fast diff avg
-5 A
78 605
-84 Too Slow C
43 521
-55 Too Slow F
67 1055
-16 Too Slow Min 43 521
-84 25th percentile 50 632
-36 Median 67 768
-1 75th percentile 76 852 15 Max 109 1055 120 D1 Participant RMSE WRS RMSE D1 diff avg Time to leakage D
70 698 95 Too Short Metric Acceptance E
49 713 23 Acceptable RMSE WRS
85 G
82 939 23 Acceptable RMSE D1
950 B
114 1234 156 Too Short diff avg
-75 A
86 1079
-68 Too Long diff avg
75 C
53 627
-71 Acceptable F
59 914 1 Acceptable Min 49 627
-71 25th percentile 56 706
-34 Median 70 914 23 75th percentile 84 1009 59 Max 114 1234 156 Axial Stress / Circ Flaw Growth Axial WRS Hoop Stress / Axial Flaw Growth Hoop WRS
E-3 E.2 Root Mean Square Error on Second Derivative E.2.1 Definition for RMSED2 The first additional metric investigated was root mean square error (RMSE) on the second derivative of WRS with respect to through-wall position. This quality metric is related to through-wall WRS trends and is a true measure of concavity.
2=
1
1 4 2 (+2 2 + 2) where t
r xnorm =
is the through-wall position normalized to the wall thickness, h is the distance between the kth and k+1th data point (h should not vary from interval to interval), WRSk is the analysts predicted stress magnitude at the kth position through the wall thickness, and WRSkmean is the cross-sectional mean prediction. The RMSE on the second derivative was calculated according to:
2 =
1 4 (22
)
2
=3 where L is the number of equally-spaced points chosen to represent the WRS profile through the wall thickness (from x/t = 0 to x/t = 1), D2k is the second derivative of the analysts predicted stress magnitude at the kth position through the wall thickness, and D2kmean is the second derivative of the cross-sectional mean prediction.
E.2.2 Results and Assessment for RMSED2 RMSED2 was calculated for both axial and hoop WRS, as shown in Figure E-2. The acceptance criterion for RMSED2 was set to RMSED2<22340 for axial WRS, and to RMSED2<23145 for hoop WRS. These values were chosen such that all the participants whose WRS prediction resulted in acceptable crack growth passed the criterion for the RMSED2 metric. In Figure E-2, the cells highlighted in green on the left-side tables meet the corresponding acceptance measures shown in the tables on the right.
For axial WRS, the acceptance criterion that had to be set for RMSED2 does not allow for a distinction to be made between the WRS predictions that resulted in similar crack growth (hereafter referred to as good predictions) and those that did not (hereafter referred to as bad predictions). In fact, all the participants meet the acceptance criterion for the RMSED2 metric, because participant G, who predicted similar crack growth, had the highest RMSED2 of all participants.
For hoop WRS, not in all cases except for participant D, the acceptance criterion that had to be set for RMSED2 allows for a distinction between the WRS predictions that resulted in acceptable time to leakage (hereafter referred to as good predictions) and those that did not (hereafter referred to as bad predictions). Importantly, in all cases except for participant D, RMSEWRS and RMSED1 were also able to distinguish between the WRS predictions that resulted in acceptable time to leakage and those that did not.
E-4 In summary, there is no added benefit to using the RMSED2 metric, since it is not able to distinguish between the good and the bad WRS predictions any better than the RMSEWRS and RMSED1 metrics.
Figure E-2 Quality metrics for Phase 2b isotropic predictions, including RMSED2. (left),
and acceptance measures for the proposed metrics (right).
D2 Participant RMSE WRS RMSE D1 RMSE D2 diff avg Crack Growth D
52 768 17734 8 Similar Metric Acceptance E
48 660 16033 22 Similar RMSE WRS
75 G
74 865 22340
-1 Similar RMSE D1
900 B
109 839 18379 120 Too Fast RMSE D2
22340 A
78 605 14546
-84 Too Slow diff avg
-5 C
43 521 15796
-55 Too Slow F
67 1055 20787
-16 Too Slow Min 43 521 14546
-84 25th percentile 50 632 15915
-36 Median 67 768 17734
-1 75th percentile 76 852 19583 15 Max 109 1055 22340 120 D2 Participant RMSE WRS RMSE D1 RMSE D2 diff avg Time to leakage D
70 698 17087 95 Too Short Metric Acceptance E
49 713 14652 23 Acceptable RMSE WRS
85 G
82 939 23145 23 Acceptable RMSE D1
950 B
114 1234 25551 156 Too Short RMSE D2
23145 A
86 1079 34326
-68 Too Long diff avg
-75 C
53 627 16645
-71 Acceptable diff avg
75 F
59 914 17033 1 Acceptable Min 49 627 14652
-71 25th percentile 56 706 16839
-34 Median 70 914 17087 23 75th percentile 84 1009 24348 59 Max 114 1234 34326 156 Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Axial WRS Hoop WRS
E-5 E.3 Truncated Metrics E.3.1 Definitions for Truncated Metrics Truncated RMSEWRS and RMSED1 metrics were investigated to determine if a truncation limit for the calculation of RMSE would improve the ability to distinguish between the good and bad WRS predictions. The following equations define (RMSEWRS)T and (RMSED1)T.
()= 1
(
)
1 (1)
1 1 (11
)
=2 where LT is the number of equally-spaced points where WRS or D1 are known, up to the truncation limit T, with 0<T<1. For example, for T=0.55, if there are 100 equally-spaced points through the wall thickness where WRS and D1 are known, LT would be equal to 55. WRSk and D1k are the WRS and first derivative of the WRS at the kth position through the wall thickness, and WRSkmean and D1kmean are the WRS and first derivative of the cross-sectional mean prediction.
(RMSEWRS)T and (RMSED1)T were calculated for T=0.1, 0.2,, 0.9, as shown in E.3.2. In addition, (RMSEWRS)T and (RMSED1)T were calculated for T=a/t(10 years) and T=a/t(20 years), as shown in Section E.3.3 and Section E.3.4, respectively.
E.3.2 Assessment of Arbitrary Truncation Figure E-3 through Figure E-11 show the results for the analysis of truncated metrics (RMSEWRS)T and (RMSED1)T for T=0.1, 0.2,, 0.9. As in previous figures, the cells highlighted in green on the left-side tables meet the corresponding acceptance measures shown in the tables on the right. In addition, the cells with green text and green background in the tables on the right (showing the acceptance measures) indicate the cases where the acceptance measures could be narrowed as compared to the criteria in Sections 5.4.9 and 5.4.11. These are the cases where using the truncated metrics results in a better ability to distinguish between good and bad WRS predictions.
Finally, the cells highlighted in yellow/orange in the left-side tables correspond to cases where the acceptance measures for (RMSEWRS)T, (RMSED1)T, and diffavg are met, but where the crack growth or time-to-leakage predictions are not satisfactory. These cases are considered false positives and correspond to cases where the truncated criteria results are unable to correctly distinguish between good and bad WRS predictions.
Below each figure in this section, a case-by-case assessment is provided. Overall, the truncated metrics do not offer any clear improvement over the basic metrics proposed in this report (see Sections 5.4.8 and 5.4.10).
E-6 Figure E-3 Truncated Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.1 Assessment of truncated metrics for T=0.1:
Acceptance measures:
o Narrower (improved) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall no improvement in acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial WRS o False positive for prediction A for hoop WRS o Less ability to distinguish than basic metrics proposed in 5.4.8 and 5.4.10 T=0.1 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
22 808 8 Similar Metric Acceptance E
51 1612 22 Similar (RMSE WRS ) T
52 G
16 936
-1 Similar (RMSE D1 ) T
1615 B
121 721 120 Too Fast diff avg
-5 A
86 433
-84 Too Slow C
55 97
-55 Too Slow F
72 2352
-16 Too Slow Min 16 97
-84 25th percentile 37 577
-36 Median 55 808
-1 75th percentile 79 1274 15 Max 121 2352 120 T=0.1 Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
98 733 95 Too Short Metric Acceptance E
35 1050 23 Acceptable (RMSE WRS ) T
75 G
52 1755 23 Acceptable (RMSE D1 ) T
2450 B
160 1129 156 Too Short diff avg
-75 A
66 748
-68 Too Long diff avg
75 C
72 356
-71 Acceptable F
74 2423 1 Acceptable Min 35 356
-71 25th percentile 59 741
-34 Median 72 1050 23 75th percentile 86 1442 59 Max 160 2423 156 Hoop Stress / Axial Flaw Growth Axial Stress / Circ Flaw Growth Hoop WRS Axial WRS
E-7 Figure E-4 Truncated Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.2 Assessment of truncated metrics for T=0.2:
Acceptance measures:
o Identical (RMSEWRS)T acceptance criterion for axial WRS o Wider (worse) (RMSEWRS)T acceptance criterion for hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial WRS o False positive for prediction A for hoop WRS o Less ability to distinguish than basic metrics proposed in 5.4.8 and 5.4.10 T=0.2 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Crack Growth D
47 708 8 Similar Metric Acceptance E
72 1221 22 Similar (RMSE WRS) T
75 G
72 1011
-1 Similar (RMSE D1) T
1225 B
109 583 120 Too Fast diff avg
-5 A
72 357
-84 Too Slow C
48 249
-55 Too Slow F
95 1636
-16 Too Slow Min 47 249
-84 25th percentile 60 470
-36 Median 72 708
-1 75th percentile 84 1116 15 Max 109 1636 120 T=0.2 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Time to leakage D
74 823 95 Too Short Metric Acceptance E
58 827 23 Acceptable (RMSE WRS) T
120 G
116 1363 23 Acceptable (RMSE D1) T
1750 B
125 1094 156 Too Short diff avg
-75 A
78 1015
-68 Too Long diff avg
75 C
62 326
-71 Acceptable F
100 1721 1 Acceptable Min 58 326
-71 25th percentile 68 825
-34 Median 78 1015 23 75th percentile 108 1229 59 Max 125 1721 156 Axial WRS Hoop WRS Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth
E-8 Figure E-5 Truncated Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.3 Assessment of truncated metrics for T=0.3:
Acceptance measures:
o Wider (worse) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial WRS o False positive for prediction A for hoop WRS o Less ability to distinguish than basic metrics proposed in 5.4.8 and 5.4.10 T=0.3 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Crack Growth D
44 715 8 Similar Metric Acceptance E
66 1006 22 Similar (RMSE WRS) T
82 G
81 870
-1 Similar (RMSE D1) T
1050 B
97 573 120 Too Fast diff avg
-5 A
75 507
-84 Too Slow C
47 336
-55 Too Slow F
85 1544
-16 Too Slow Min 44 336
-84 25th percentile 57 540
-36 Median 75 715
-1 75th percentile 83 938 15 Max 97 1544 120 T=0.3 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Time to leakage D
63 748 95 Too Short Metric Acceptance E
51 740 23 Acceptable (RMSE WRS) T
120 G
120 1181 23 Acceptable (RMSE D1) T
1500 B
104 1064 156 Too Short diff avg
-75 A
74 1030
-68 Too Long diff avg
75 C
52 456
-71 Acceptable F
102 1498 1 Acceptable Min 51 456
-71 25th percentile 57 744
-34 Median 74 1030 23 75th percentile 103 1123 59 Max 120 1498 156 Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Axial WRS Hoop WRS
E-9 Figure E-6 Truncated Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.4 Assessment of truncated metrics for T=0.4:
Acceptance measures:
o Identical (RMSEWRS)T acceptance criterion for axial WRS o Wider (worse) (RMSEWRS)T acceptance criterion for hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial WRS o False positive for prediction A for hoop WRS o Less ability to distinguish than basic metrics proposed in 5.4.8 and 5.4.10 T=0.4 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Crack Growth D
53 808 8 Similar Metric Acceptance E
62 933 22 Similar (RMSE WRS) T
75 G
73 1022
-1 Similar (RMSE D1) T
1025 B
85 606 120 Too Fast diff avg
-5 A
86 544
-84 Too Slow C
46 517
-55 Too Slow F
79 1401
-16 Too Slow Min 46 517
-84 25th percentile 57 575
-36 Median 73 808
-1 75th percentile 82 977 15 Max 86 1401 120 T=0.4 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Time to leakage D
68 769 95 Too Short Metric Acceptance E
51 764 23 Acceptable (RMSE WRS) T
110 G
108 1118 23 Acceptable (RMSE D1) T
1350 B
92 1068 156 Too Short diff avg
-75 A
82 1081
-68 Too Long diff avg
75 C
48 547
-71 Acceptable F
90 1331 1 Acceptable Min 48 547
-71 25th percentile 60 766
-34 Median 82 1068 23 75th percentile 91 1099 59 Max 108 1331 156 Axial Stress / Circ Flaw Growth Axial WRS Hoop Stress / Axial Flaw Growth Hoop WRS
E-10 Figure E-7 Truncated Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.5 Assessment of truncated metrics for T=0.5:
Acceptance measures:
o Wider (worse) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial and hoop WRS o Same ability to distinguish as basic metrics proposed in 5.4.8 and 5.4.10 T=0.5 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Crack Growth D
61 807 8 Similar Metric Acceptance E
57 863 22 Similar (RMSE WRS) T
78 G
78 951
-1 Similar (RMSE D1) T
955 B
85 629 120 Too Fast diff avg
-5 A
79 636
-84 Too Slow C
42 522
-55 Too Slow F
73 1338
-16 Too Slow Min 42 522
-84 25th percentile 59 632
-36 Median 73 807
-1 75th percentile 79 907 15 Max 85 1338 120 T=0.5 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Time to leakage D
89 765 95 Too Short Metric Acceptance E
55 726 23 Acceptable (RMSE WRS) T
100 G
98 1037 23 Acceptable (RMSE D1) T
1205 B
97 1155 156 Too Short diff avg
-75 A
110 1158
-68 Too Long diff avg
75 C
62 605
-71 Acceptable F
80 1204 1 Acceptable Min 55 605
-71 25th percentile 71 746
-34 Median 89 1037 23 75th percentile 98 1157 59 Max 110 1204 156 Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Hoop WRS Axial WRS
E-11 Figure E-8 Truncated Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.6 Assessment of truncated metrics for T=0.6:
Acceptance measures:
o Wider (worse) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial and hoop WRS o Same ability to distinguish as basic metrics proposed in 5.4.8 and 5.4.10 T=0.6 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Crack Growth D
57 807 8 Similar Metric Acceptance E
52 793 22 Similar (RMSE WRS) T
85 G
82 876
-1 Similar (RMSE D1) T
900 B
93 601 120 Too Fast diff avg
-5 A
77 680
-84 Too Slow C
39 485
-55 Too Slow F
70 1228
-16 Too Slow Min 39 485
-84 25th percentile 54 640
-36 Median 70 793
-1 75th percentile 79 841 15 Max 93 1228 120 T=0.6 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Time to leakage D
86 802 95 Too Short Metric Acceptance E
52 762 23 Acceptable (RMSE WRS) T
90 G
90 964 23 Acceptable (RMSE D1) T
1120 B
124 1103 156 Too Short diff avg
-75 A
105 1171
-68 Too Long diff avg
75 C
58 717
-71 Acceptable F
74 1119 1 Acceptable Min 52 717
-71 25th percentile 66 782
-34 Median 86 964 23 75th percentile 98 1111 59 Max 124 1171 156 Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Axial WRS Hoop WRS
E-12 Figure E-9 Truncated Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.7 Assessment of truncated metrics for T=0.7:
Acceptance measures:
o Wider (worse) (RMSEWRS)T acceptance criterion for axial WRS o Identical (RMSEWRS)T acceptance criterion for hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial and hoop WRS o Same ability to distinguish as basic metrics proposed in 5.4.8 and 5.4.10 T=0.7 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Crack Growth D
53 756 8 Similar Metric Acceptance E
49 753 22 Similar (RMSE WRS) T
85 G
83 909
-1 Similar (RMSE D1) T
910 B
89 921 120 Too Fast diff avg
-5 A
81 640
-84 Too Slow C
36 472
-55 Too Slow F
66 1157
-16 Too Slow Min 36 472
-84 25th percentile 51 697
-36 Median 66 756
-1 75th percentile 82 915 15 Max 89 1157 120 T=0.7 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Time to leakage D
81 743 95 Too Short Metric Acceptance E
50 743 23 Acceptable (RMSE WRS) T
85 G
85 959 23 Acceptable (RMSE D1) T
1040 B
125 1269 156 Too Short diff avg
-75 A
97 1094
-68 Too Long diff avg
75 C
57 678
-71 Acceptable F
69 1040 1 Acceptable Min 50 678
-71 25th percentile 63 743
-34 Median 81 959 23 75th percentile 91 1067 59 Max 125 1269 156 Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Axial WRS Hoop WRS
E-13 Figure E-10 Truncated Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.8 Assessment of truncated metrics for T=0.8:
Acceptance measures:
o Wider (worse) (RMSEWRS)T acceptance criterion for axial WRS o Identical (RMSEWRS)T acceptance criterion for hoop WRS o Narrower (better) (RMSED1)T acceptance criterion for axial WRS o Wider (worse) (RMSED1)T acceptance criterion for hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial and hoop WRS o Same ability to distinguish as basic metrics proposed in 5.4.8 and 5.4.10 T=0.8 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Crack Growth D
52 734 8 Similar Metric Acceptance E
50 710 22 Similar (RMSE WRS) T
80 G
78 893
-1 Similar (RMSE D1) T
895 B
96 920 120 Too Fast diff avg
-5 A
84 602
-84 Too Slow C
42 507
-55 Too Slow F
64 1099
-16 Too Slow Min 42 507
-84 25th percentile 51 656
-36 Median 64 734
-1 75th percentile 81 907 15 Max 96 1099 120 T=0.8 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Time to leakage D
76 746 95 Too Short Metric Acceptance E
50 740 23 Acceptable (RMSE WRS) T
85 G
85 917 23 Acceptable (RMSE D1) T
1010 B
117 1233 156 Too Short diff avg
-75 A
93 1123
-68 Too Long diff avg
75 C
55 656
-71 Acceptable F
65 1007 1 Acceptable Min 50 656
-71 25th percentile 60 743
-34 Median 76 917 23 75th percentile 89 1065 59 Max 117 1233 156 Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Axial WRS Hoop WRS
E-14 Figure E-11 Truncated Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=0.9 Assessment of truncated metrics for T=0.9:
Acceptance measures:
o Wider (worse) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial and hoop WRS o Same ability to distinguish as basic metrics proposed in 5.4.8 and 5.4.10 E.3.3 Assessment of Truncation at 10 Years Crack Growth Figure E-12 shows the results for the analysis of truncated metrics (RMSEWRS)T and (RMSED1)T for T=a/t(10 years), which vary by participant. As in previous figures, the cells highlighted in green T=0.9 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Crack Growth D
52 741 8 Similar Metric Acceptance E
50 674 22 Similar (RMSE WRS) T
80 G
77 876
-1 Similar (RMSE D1) T
900 B
105 871 120 Too Fast diff avg
-5 A
82 633
-84 Too Slow C
45 532
-55 Too Slow F
69 1064
-16 Too Slow Min 45 532
-84 25th percentile 51 654
-36 Median 69 741
-1 75th percentile 80 874 15 Max 105 1064 120 T=0.9 Truncated Participant (RMSE WRS) T (RMSE D1 ) T diff avg Time to leakage D
73 715 95 Too Short Metric Acceptance E
51 719 23 Acceptable (RMSE WRS) T
86 G
86 910 23 Acceptable (RMSE D1) T
955 B
114 1238 156 Too Short diff avg
-75 A
90 1128
-68 Too Long diff avg
75 C
54 649
-71 Acceptable F
62 955 1 Acceptable Min 51 649
-71 25th percentile 58 717
-34 Median 73 910 23 75th percentile 88 1042 59 Max 114 1238 156 Hoop Stress / Axial Flaw Growth Axial Stress / Circ Flaw Growth Axial WRS Hoop WRS
E-15 on the left-side tables meet the corresponding acceptance measures shown in the tables on the right. In addition, the cells with green text and green background in the right-side tables (showing the acceptance measures) indicate the cases where the acceptance measures could be narrowed as compared to the criteria presented in Sections 5.4.9 and 5.4.11. These are the cases where using the truncated metrics results in a better ability to distinguish between good and bad WRS predictions. There are no such cases for truncation at T=a/t(10 years). Finally, the cells highlighted in yellow/orange in the left-side tables correspond to cases where the acceptance measures for (RMSEWRS)T, (RMSED1)T, and diffavg are met, but where the crack growth or time-to-leakage predictions are not satisfactory. These cases are considered false positives and correspond to cases where the truncated criteria results are unable to correctly distinguish between good and bad WRS predictions. There are no such cases for truncation at T=a/t(10 years).
Figure E-12 Truncated Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T=a/t(10 years)
Assessment of truncated metrics for T=a/t(10 years):
T = a/t (10 yrs)
Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
34 831 8 Similar Metric Acceptance E
58 889 22 Similar (RMSE WRS ) T
75 G
75 1009
-1 Similar (RMSE D1 ) T
1010 B
109 835 120 Too Fast diff avg
-5 A
86 433
-84 Too Slow C
55 97
-55 Too Slow F
72 2352
-16 Too Slow Min 45 532
-84 25th percentile 51 654
-36 Median 69 741
-1 75th percentile 80 874 15 Max 105 1064 120 T = a/t (10 yrs)
Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
70 695 95 Too Short Metric Acceptance E
49 709 23 Acceptable (RMSE WRS ) T
82 G
82 935 23 Acceptable (RMSE D1 ) T
1050 B
114 1228 156 Too Short diff avg
-75 A
110 1147
-68 Too Long diff avg
75 C
54 653
-71 Acceptable F
69 1040 1 Acceptable Min 51 649
-71 25th percentile 58 717
-34 Median 73 910 23 75th percentile 88 1042 59 Max 114 1238 156 Axial Stress / Circ Flaw Growth Axial WRS Hoop Stress / Axial Flaw Growth Hoop WRS
E-16 Acceptance measures:
o Identical (RMSEWRS)T acceptance criterion for axial WRS o Marginally narrower (better) (RMSEWRS)T acceptance criterion for hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall widening of acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial and hoop WRS o Same ability to distinguish as basic metrics proposed in 5.4.8 and 5.4.10 Overall, it can be said that truncated metrics with T=a/t(10 years) do not offer any clear improvement over the basic metrics proposed in this report (see 5.4.8 and 5.4.10).
E.3.4 Assessment of Truncation at 20 Years Crack Growth Figure E-13 shows the results for the analysis of truncated metrics (RMSEWRS)T and (RMSED1)T for T=a/t(20 years), which varies by participant. As in previous figures, the cells highlighted in green on the left-side tables meet the corresponding acceptance measures shown in the tables on the right. In addition, the cells with green text and green background in the right-side tables (showing the acceptance measures) indicate the cases where the acceptance measures could be narrowed as compared to the criteria presented in Sections 5.4.9 and 5.4.11. These are the cases where using the truncated metrics results in a better ability to distinguish between good and bad WRS predictions. There are no such cases for truncation at T=a/t(20 years). Finally, the cells highlighted in yellow/orange in the left-side tables correspond to cases where the acceptance measures for (RMSEWRS)T, (RMSED1)T, and diffavg are met, but where the crack growth or time-to-leakage predictions are not satisfactory. These cases are considered false positives and correspond to cases where the truncated criteria results are unable to correctly distinguish between good and bad WRS predictions. There are no such cases for truncation at T=a/t(20 years).
Assessment of truncated metrics for T=a/t(20 years):
Acceptance measures:
o Identical (RMSEWRS)T acceptance criterion for axial WRS o Marginally narrower (better) (RMSEWRS)T acceptance criterion for hoop WRS o Wider (worse) (RMSED1)T acceptance criterion for axial WRS o Marginally narrower (better) (RMSED1)T acceptance criterion for hoop WRS o Overall marginal improvement on acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial and hoop WRS o Same ability to distinguish as basic metrics proposed in 5.4.8 and 5.4.10 Overall, the truncated metrics with T=a/t(20 years) do not offer any clear improvement over the basic metrics proposed in this report (see Sections 5.4.8 and 5.4.10). In fact, although these metrics provide a marginal improvement on acceptance measures ranges, they require the performance of crack growth predictions, which is a burdensome exercise that is not worth the very small gains achieved.
E-17 Figure E-13 Truncated Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for T= a/t(20 years)
T = a/t (20 yrs)
Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Crack Growth D
46 721 8 Similar Metric Acceptance E
58 889 22 Similar (RMSE WRS ) T
75 G
75 1009
-1 Similar (RMSE D1 ) T
1010 B
109 835 120 Too Fast diff avg
-5 A
86 433
-84 Too Slow C
55 97
-55 Too Slow F
72 2352
-16 Too Slow Min 45 532
-84 25th percentile 51 654
-36 Median 69 741
-1 75th percentile 80 874 15 Max 105 1064 120 T = a/t (20 yrs)
Truncated Participant (RMSE WRS ) T (RMSE D1 ) T diff avg Time to leakage D
70 695 95 Too Short Metric Acceptance E
49 709 23 Acceptable (RMSE WRS ) T
82 G
82 935 23 Acceptable (RMSE D1 ) T
935 B
114 1228 156 Too Short diff avg
-75 A
111 1167
-68 Too Long diff avg
75 C
53 624
-71 Acceptable F
59 909 1 Acceptable Min 51 649
-71 25th percentile 58 717
-34 Median 73 910 23 75th percentile 88 1042 59 Max 114 1238 156 Axial Stress / Circ Flaw Growth Axial WRS Hoop Stress / Axial Flaw Growth Hoop WRS
E-18 E.4 Weighted Metrics E.4.1 Definitions for Weighted Metrics Truncated RMSEWRS and RMSED1 metrics were investigated to determine if a weight function for the calculation of RMSE would improve the ability to distinguish between the good and bad WRS predictions. The following equations define (RMSEWRS)W and (RMSED1)W:
()= 1 1
(
)
1 (1)
1 2 1
(11
)
1
=2 where L is the number of equally-spaced points chosen to represent the WRS profile through the wall thickness (from x/t = 0 to x/t = 1), W is the weight exponent, xk/t is the normalized through-thickness distance at the kth position through the wall thickness, WRSk and D1k are the WRS and first derivative of the WRS at the kth position through the wall thickness, and WRSkmean and D1kmean are the WRS and first derivative of the cross-sectional mean prediction.
(RMSEWRS)W and (RMSED1)W were calculated for W=1, 2, 5, 10, as shown in Section E.4.2. The weight function gives higher weight to values of (WRSk-WRSkmean) or (D1k-D1kmean) closer to x/t = 0. Furthermore, as the weight exponent increases, the weight function eventually takes values smaller than 1%, essentially truncating the RMSE calculation beyond a certain point, as illustrated in Figure E-14.
Figure E-14 Weight Function as a Function of Weight Exponent W
E-19 E.4.2 Results and Assessment for Weighted Metrics Figure E-15 though Figure E-18 show the results for the analysis of weighted metrics (RMSEWRS)W and (RMSED1)W for W=1, 2, 5, and 10. As in previous figures, the cells highlighted in green on the left-side tables meet the corresponding acceptance measures shown in the tables on the right. In addition, the cells with green text and green background in the right-side tables (showing the acceptance measures) indicate the cases where the acceptance measures could be narrowed as compared to the criteria presented in 5.4.9 and 5.4.11. These are the cases where using the weighted metrics results in a better ability to distinguish between good and bad WRS predictions.
Finally, the cells highlighted in yellow/orange in the left-side tables correspond to cases where the acceptance measures for (RMSEWRS)W, (RMSED1)W, and diffavg are met, but where the crack growth or time to leakage predictions are not satisfactory. These cases are considered false positives and correspond to cases where the weighted criteria results are unable to correctly distinguish between good and bad WRS predictions.
Below each figure in this section, a case-by-case assessment is provided. Overall, weighted metrics allow for a significant narrowing of the acceptance measures for both axial and hoop WRS, which is an improvement over the basic metrics proposed in Sections 5.4.8 and 5.4.10.
However, in all cases investigated where W>1, some false positives occur for hoop WRS.
Consequently, the weighted metrics do not offer any improvement over the basic metrics proposed in this report (see Sections 5.4.8 and 5.4.10).
E-20 Figure E-15 Weighted Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for W=1 Assessment of weighted metrics for W=1:
Acceptance measures:
o Narrower (improved) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Narrower (improved) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall significant improvement in acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial and hoop WRS o Same ability to distinguish as basic metrics proposed in 5.4.8 and 5.4.10 W=1 Weighted Participant (RMSE WRS) W (RMSE D1 ) W diff avg Crack Growth D
37 540 8 Similar Metric Acceptance E
38 581 22 Similar (RMSE WRS) W
55 G
55 645
-1 Similar (RMSE D1) W
645 B
68 555 120 Too Fast diff avg
-5 A
57 429
-84 Too Slow C
30 342
-55 Too Slow F
51 889
-16 Too Slow Min 30 342
-84 25th percentile 38 485
-36 Median 51 555
-1 75th percentile 56 613 15 Max 68 889 120 W=1 Weighted Participant (RMSE WRS) W (RMSE D1 ) W diff avg Time to leakage D
55 531 95 Too Short Metric Acceptance E
36 530 23 Acceptable (RMSE WRS) W
65 G
65 719 23 Acceptable (RMSE D1) W
830 B
81 839 156 Too Short diff avg
-75 A
66 778
-68 Too Long diff avg
75 C
40 443
-71 Acceptable F
53 828 1 Acceptable Min 36 443
-71 25th percentile 46 531
-34 Median 55 719 23 75th percentile 66 803 59 Max 81 839 156 Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Axial WRS Hoop WRS
E-21 Figure E-16 Weighted Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for W=2 Assessment of weighted metrics for W=2:
Acceptance measures:
o Narrower (improved) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Narrower (improved) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall significant improvement in acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial WRS o False positive for prediction A for hoop WRS o Less ability to distinguish than basic metrics proposed in 5.4.8 and 5.4.10 W=2 Weighted Participant (RMSE WRS) W (RMSE D1 ) W diff avg Crack Growth D
30 442 8 Similar Metric Acceptance E
33 541 22 Similar (RMSE WRS) W
45 G
44 538
-1 Similar (RMSE D1) W
550 B
55 408 120 Too Fast diff avg
-5 A
46 334
-84 Too Slow C
25 257
-55 Too Slow F
44 814
-16 Too Slow Min 25 257
-84 25th percentile 32 371
-36 Median 44 442
-1 75th percentile 45 539 15 Max 55 814 120 W=2 Weighted Participant (RMSE WRS) W (RMSE D1 ) W diff avg Time to leakage D
46 443 95 Too Short Metric Acceptance E
30 445 23 Acceptable (RMSE WRS) W
60 G
57 638 23 Acceptable (RMSE D1) W
790 B
66 662 156 Too Short diff avg
-75 A
53 620
-68 Too Long diff avg
75 C
33 337
-71 Acceptable F
48 782 1 Acceptable Min 30 337
-71 25th percentile 39 444
-34 Median 48 620 23 75th percentile 55 650 59 Max 66 782 156 Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Axial WRS Hoop WRS
E-22 Figure E-17 Weighted Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for W=5 Assessment of weighted metrics for W=5:
Acceptance measures:
o Narrower (improved) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Narrower (improved) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall significant improvement in acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial WRS o False positive for prediction A for hoop WRS o Less ability to distinguish than basic metrics proposed in 5.4.8 and 5.4.10 W=5 Weighted Participant (RMSE WRS) W (RMSE D1 ) W diff avg Crack Growth D
19 302 8 Similar Metric Acceptance E
26 474 22 Similar (RMSE WRS) W
30 G
28 386
-1 Similar (RMSE D1) W
475 B
42 259 120 Too Fast diff avg
-5 A
33 200
-84 Too Slow C
20 141
-55 Too Slow F
34 698
-16 Too Slow Min 19 141
-84 25th percentile 23 230
-36 Median 28 302
-1 75th percentile 34 430 15 Max 42 698 120 W=5 Weighted Participant (RMSE WRS) W (RMSE D1 ) W diff avg Time to leakage D
32 318 95 Too Short Metric Acceptance E
21 337 23 Acceptable (RMSE WRS) W
45 G
42 525 23 Acceptable (RMSE D1) W
710 B
50 452 156 Too Short diff avg
-75 A
34 395
-68 Too Long diff avg
75 C
25 189
-71 Acceptable F
38 704 1 Acceptable Min 21 189
-71 25th percentile 28 328
-34 Median 34 395 23 75th percentile 40 489 59 Max 50 704 156 Axial Stress / Circ Flaw Growth Hoop Stress / Axial Flaw Growth Axial WRS Hoop WRS
E-23 Figure E-18 Weighted Quality Metrics for Phase 2b Isotropic Predictions (left), and Acceptance measures for the Proposed Metrics (right), for W=10 Assessment of weighted metrics for W=10:
Acceptance measures:
o Narrower (improved) (RMSEWRS)T acceptance criterion for axial and hoop WRS o Narrower (improved) (RMSED1)T acceptance criterion for axial and hoop WRS o Overall significant improvement in acceptance measures Ability to distinguish between good and bad predictions:
o Good for axial WRS o False positive for prediction A for hoop WRS o Less ability to distinguish than basic metrics proposed in 5.4.8 and 5.4.10 W=10 Weighted Participant (RMSE WRS) W (RMSE D1 ) W diff avg Crack Growth D
12 208 8 Similar Metric Acceptance E
19 411 22 Similar (RMSE WRS) W
20 G
17 276
-1 Similar (RMSE D1) W
415 B
34 204 120 Too Fast diff avg
-5 A
26 132
-84 Too Slow C
16 70
-55 Too Slow F
26 607
-16 Too Slow Min 12 70
-84 25th percentile 16 168
-36 Median 19 208
-1 75th percentile 26 344 15 Max 34 607 120 W=10 Weighted Participant (RMSE WRS) W (RMSE D1 ) W diff avg Time to leakage D
26 239 95 Too Short Metric Acceptance E
14 273 23 Acceptable (RMSE WRS) W
30 G
27 428 23 Acceptable (RMSE D1) W
630 B
42 338 156 Too Short diff avg
-75 A
23 252
-68 Too Long diff avg
75 C
20 114
-71 Acceptable F
28 628 1 Acceptable Min 14 114
-71 25th percentile 21 245
-34 Median 26 273 23 75th percentile 28 383 59 Max 42 628 156 Hoop Stress / Axial Flaw Growth Axial Stress / Circ Flaw Growth Hoop WRS Axial WRS
NUREG-2228 Michael L. Benson Patrick A. C. Raynaud Jay S. Wallace Division of Engineering, Office of Research U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Same as above Under a Memorandum of Understanding, the U.S. Nuclear Regulatory Commission and the Electric Power Research Institute conducted a research program aimed at gathering data on weld residual stress modeling.
As described in NUREG-2162, Weld Residual Stress Finite Element Analysis Validation: Part IData Development Effort, issued March 2014, this program consisted of round robin measurement and modeling studies on various mockups. At that time, the assessment of the data was qualitative. This report describes an additional residual stress round robin study and a methodology for capturing residual stress uncertainties.
This quantitative approach informed the development of guidelines and a validation methodology for finite element prediction of weld residual stress. For example, comparisons of modeling results to measurements provided a basis for establishing guidance on a material hardening approach for residual stress models.
The proposed validation procedure involves an analyst modeling a known case (the Phase 2b round robin mockup) and comparing results to two proposed quality metrics. These recommendations provide a potential method by which analysts can bolster confidence in their modeling practices for regulatory applications.
weld residual stress, finite element modeling, model validation, flaw evaluation, uncertainty characterization July 2020 Technical Weld Residual Stress Finite Element Analysis Validation Part IIProposed Validation Procedure Final Report
NUREG-2228 Final Weld Residual Stress Finite Element Analysis Validation Part IIProposed Validation Procedure July 2020