NSD-NRC-97-5139, Forwards Rev 3 to DE-AC03-90SF18495, Simplified Passive Advanced LWR Plant Program,AP600 Certified Design Matl. NRC Should Review Matl as Part of AP600 Design Certification Review

From kanterella
(Redirected from ML20141H106)
Jump to navigation Jump to search
Forwards Rev 3 to DE-AC03-90SF18495, Simplified Passive Advanced LWR Plant Program,AP600 Certified Design Matl. NRC Should Review Matl as Part of AP600 Design Certification Review
ML20141H106
Person / Time
Site: 05200003
Issue date: 05/19/1997
From: Mcintyre B
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Quay T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20141H109 List:
References
NSD-NRC-97-5139, NUDOCS 9705230195
Download: ML20141H106 (1)


Text

m CN (Q

Westinghouse Energy Systems

$sl5' Electric Corporation u gn eennsvivania 15230 0355 NSD-NRC-97-5139 DCP/NRC0873 Docket No.: STN-52-003 May 19,1997 Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

T. R. QUAY

SUBJECT:

REVISION 3 OF THE AP600 CERTIFIED DESIGN MATERIAL

Dear Mr. Quay:

Enclosed is Revision 3 of the AP600 CertiGed Design Material (CDM), including the Inspections,

,j Tests, Analyses and Acceptance Criteria (ITAAC). This revision supersedes Revision 2 which was submitted in November,1996. This review incorporates NRC comments as transmitted in your letter.

of March 4,1997, and April 18,1997. This revision is a complete replacement, except for the binder and tabs. Thirty-six copies of this update are being sent to Mrs. Diane Jackson for distribution to the NRC staff.

This information includes no infonnation classiGed as proprietary.

The NRC should review this material as a part of the AP600 Desi n Certification Review.

F Please contact Brian A. McIntyre on (412) 374-4334 if you have any questions concerning this transmittal.

Brian A. McIntyre, Manager Advanced Plant Safety and Licensing jml Attachments hh I

Enclosures V

cc:

D. Jackson, NRC h.gf l [g p

J. Sebrosky, NRC N. Liparuto, Westinghouse (w/o Attachments and Enclosures)

$ff'{htFl 23903 9705230195 970519 PDR ADOCK 05200003 A

PDR