NSD-NRC-97-5167, Forwards EPRI Rept, Effects of Inhibitors & Poisons on Performance of Passive Autocatalytic Recombiners (Pars) for Combustible Gas Control in Alwrs, Requested by NRC Staff During Hydrogen Control Meeting on 970520
| ML20140C467 | |
| Person / Time | |
|---|---|
| Site: | 05200003 |
| Issue date: | 06/06/1997 |
| From: | Mcintyre B WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP. |
| To: | Quay T NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| Shared Package | |
| ML20140C472 | List: |
| References | |
| NSD-NRC-97-5167, NUDOCS 9706090283 | |
| Download: ML20140C467 (1) | |
Text
,a
/
\\
)
(
=
v Westinghouse Energy Systems Ba 355 Electric Corporation Pittsburgh Pennsylvania 15230-0355 j
NSD-NRC-97-5167 DCP/NRC0900 Docket No.: STN-52-003 June 6,1997 Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION: T. R. QUAY
SUBJECT:
EPRI REPORT ON PASSIVE AUTOCATALYTIC RECOMBINERS POISONS
Dear Mr. Quay:
I;.iclosed are two copies of the EPRI report " Effects ofInhibitors and Poisons on the Performance of P. sive Autocatalytic Recombiners (PARS) for Combustible Gas Control in ALWRs", dated May 22, W 17. This a,iort was requested by the NRC staff during the hydrogen control meeting on May 20 Pr)7. Copics. f this report are being provided to J. Sebrosky for review by the NRC staff. This
.eport is referenced in response to action items from the May 20,1997 meeting and is expected to be referenced in SSAR revisions prepared to address action items from the May 20,1997 meeting.
This submittal will close the May 20,1997 hydrogen meeting action item 1.D.1 (OITS #5373).
Please contact D. A. Lindgren at (412) 374-4856 if you have any questions.
Cht.
itrian A. McIntyre, Manager Jvanced Plant Safety and Licensing elasures
-i*'
h' g\\
cc: J. Sebrosky, NRC - 2 Enclosures N. Liparulo, Westinghouse (w/o Enclosures)
\\
~
9706090283 970606 PDR ADOCK 05200003 PDR A
ll,lll ! f !ll!l