RBG-22-000, Responds to NRC Re Violations Noted in Insp Rept 50-458/85-31.Corrective Actions:Valve Lineup Delineated in Procedure 1-PT-57-1 Reverified

From kanterella
(Redirected from ML20138A567)
Jump to navigation Jump to search
Responds to NRC Re Violations Noted in Insp Rept 50-458/85-31.Corrective Actions:Valve Lineup Delineated in Procedure 1-PT-57-1 Reverified
ML20138A567
Person / Time
Site: River Bend 
Issue date: 09/02/1985
From: William Cahill
GULF STATES UTILITIES CO.
To: Martin R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20138A540 List:
References
RBG-22, RBG-22-000, NUDOCS 8510080589
Download: ML20138A567 (3)


Text

_.

1

p. -
  • GULF STATES UTELETEES COMPANY 4

j RIVE R SEND ST ATION PO$f O*FICE804220

$f FR A%CISVfLLE LOul54ANA 7CUS ARE A COD ( 504 635 6094 346 8eht i

j Septornber 2,1985 RDG-22,000 1

File Nos. G9.5, G15.4.1

}

Mr. Robert D. Martin, Regional Adntinistrator r

U.S. Nuclear Regulatory Ccmnission y @ ]Qgn[l l

i 4

Fegion IV 7 -

611 Ryan Plaza Drive, Suite 1000 J

i l

Arlington, Texas 76011 SEP I 01985 u

Dear Mr. Martin:

  • iy

^

River Bend Station - Unit 1 Refer to: Region IV j

i Docket No. 50-458/ Report 85-31 I

mis letter is in response to the Notice of Violation contained in NBC

'f I&E Inspection Report No. 50-458/85-31. The inspection was performed by Ms. K. A. Whittlesey and Mr. J. I. Tapia during the period April 3-8, 1985, of activities authorized by NRC Construction Permit CPPR-145 for River Bend Station Unit No. 1.

[

q Gulf States Utilities Cmpany's (CSU's) response to the Notice of Vio-j lation 85-31-01, " Inadequate Test Procedure," is provided in the enclosed i

attachment. Wis empletes GSU's response to the Notice of Violation, i

1 l

l r

j Sincerely, l

j W. J. Cahill, Jr.

l Senior Vice President River Bend Nuclear Group

\\

WL-fY'l Rfd i

M7C/7tr/TEP.

/BEH/ang

]

Attachment i

i

's i

I 4

0510000509 050930 h'

DR ADOCK O O

1

+

.. S

Refer to Docket No. 50-458/85-31.

Response to 85-31-01 " Inadequate Test Procedure" Reason For The Violation Preoperational type A test procedure 1-PT-57-1 was issued and being used to conduct the Integrated Icak Rate Test, even though six differential pres-sure instrument valves and one motor operated valve which were required to be properly positioned were in fact not included in the procedure's valve lineup.

Corrective Steps hhich IIave Been Taken and Results Achieved

'Ihe valves were identified during the performance of the test.

Maior Change Request (MCR) No. 4 was issued to revise 1-PT-57-1 to add the misn-ing valves to the lineup.

Corrective Steps khich Will Be Taken to Avoid Further Violations

'Ihe valve lineup now delineated in 1-PT-57-1 will be re-verified.

All changes made to 1-PT-57-1 will be evaluated for incorporation into the surveillance test procedure (STP).

Date hhen Full Carpliance Will Be Achieved The valve lineup delineated in 1-PT-57-1 will be re-verified by Septanber 16, 1985.

Incorporation of changes into the STP as discussed above will be canpleted by Decanber 31, 1986, prior to the scheduled perfornance of the STP.

...*,e

'.x -

UNITED STATES OF AMERICA NUCLEAR EECULATORT CO MISSION STATE OF LOUISIANA PARISH OF WEST FELICIANA 5

In the Matter of I

Docket Nos. 50-458 CULF STATES UTILITIES COMPANT I

(River Bend Station, Unit 1) e AFFIDAVIT J.

C.

Deddens, being duly sworn, states that he is a Vice President of Culf States Utilities Company that he is authorized on the part of said Company to sign and file with the Nuclear Regulatory Commission the documents attached hereto; and that all such documents are true and correct to the best of his knowledge, information and belief.

J. C//lfeddens Subscribed and sworn to before me, a Notary Public in and for the StateandParishabovenamed,this<~.$N day of

//[i/ /E 19 J

ft bb<t+kJ

~

w an W. Middlebrooks

, otary Public in and for West Feliciana Parish, Louisiana My Conssission is for Life.