NSD-NRC-97-5016, Forwards WCAP-14857, AP600 Long Term Cooling Summary Rept, Which Provides Overview of Matl Presented in Wcobra/Trac Long-Term Cooling Validation Rept (WCAP-14776)
| ML20136G341 | |
| Person / Time | |
|---|---|
| Site: | 05200003 |
| Issue date: | 03/10/1997 |
| From: | Mcintyre B WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP. |
| To: | Quay T NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| Shared Package | |
| ML20136G344 | List: |
| References | |
| NSD-NRC-97-5016, NUDOCS 9703180010 | |
| Download: ML20136G341 (2) | |
Text
_ _. _ _
l
- Westinghouse Energy Systems Ba 355 Electric Corporation Pittsburgh Pennsylvania 15230-0355 t
l DCP/NRC0765 Docket No.: STN-52-003 March 10,1997 l
Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:
T.R. QUAY j
SUBJECT:
WCAP-14857, "AP600 LONG TERM COOLING
SUMMARY
REPORT" i
l
Dear Mr. Quay:
Enclosed is WCAP-14857, "AP600 Long Term Cooling Summary Report," which provides an overview of the material presented in the WCOBRA/ TRAC Long-Term Cooling Validation Report J
(WCAP-14776). In addition, this report describes how the AP600 long term cooling plant calculations are to be performed, including the methodology used to obtain the containment conditions during the l
I The NRC should review this enclosure as it provides supplemental information for the staff's review j
of AP600 long term cooling.
i Please contact Cynthia L. IIaag on (412) 374-4277 if you have any questions concerning this transmittal.
.L Brian A. McIntyre, Manager Advanced Plant Safety and Licensing
')
I l
jml l
Enclosure cc:
W.11uffman, NRC (enclosure) b L. Lois, NRC (enclosure)
(, g P. Boehnart, ACRS (enclosure)
Dr. Ivan Catton, (enclosure)
Dr. Vijay Dhir, (enclosure)
Dr. Thomas S. Kress, ACRS (enclosure) i Dr. Mario 11. Fontana, ACRS (enclosure) l Dr. Robert L. Seale, ACRS (enclosure)
Dr. Virgil Schrock, (enclosure)
Dr. Novak Zuber, ACRS (enclosure)
N. J. Liparulo, Westinghouse (w/o enclosure) 9703180010 970310 E
PDR ADOCK 052000 3 lE,5l$$5, Egg
~o.,
.e 4
l Enclosure to Westinghouse Letter NSD-NRC-97-5016 March 10,1997 1
i j
1 I
3tl2A