ST-HL-AE-1343, Forwards Vols I-V of Exam Plan for Preservice Exam of Selected Components & Piping of South Texas Project Electric Generating Station,Unit 1. Preservice Insp Exam Plan for Eddy Current Expected to Be Submitted in Sept 1985

From kanterella
(Redirected from ML20135B617)
Jump to navigation Jump to search
Forwards Vols I-V of Exam Plan for Preservice Exam of Selected Components & Piping of South Texas Project Electric Generating Station,Unit 1. Preservice Insp Exam Plan for Eddy Current Expected to Be Submitted in Sept 1985
ML20135B617
Person / Time
Site: South Texas 
Issue date: 09/06/1985
From: Wisenberg M
HOUSTON LIGHTING & POWER CO.
To: Knighton G
Office of Nuclear Reactor Regulation
Shared Package
ML20135B620 List:
References
ST-HL-AE-1343, NUDOCS 8509110118
Download: ML20135B617 (3)


Text

I

~

The Light mmPuy "e ste> 'is ies & re-e, e.o.nex >200 >ieestee. Tex s 77ooi <7is> 228 o2ii a

September 6, 1985 ST-HL-AE-1343 File No.: T3.1 Mr. George W. Knighton, Chief Licensing Branch No. 3 Division of Licensing U. S. Nuclear Regulatory Commission Washington, DC 20555 South Texas Pr.' ject Unit 1 Docket No. STN 50-498 Unit 1 e5I Eramination Plan

Dear Mr. Knighton:

Enclosed fo your review are three (3) copies of the South Texas Project Preservice Inspection Examination Plan for Unit 1.

As prev'ously discussed with Mr. Martin Hum (MTEB), the enclosed Unit 1 PSI Examination Plan is HL&P's preliminary plan for examination of Class 1 and 2 piping and components in accordance with 10CFR50.55a and ASME Section XI. This plan will be revised during the performance of the PSI to reflect the as-built conditions determined from walk-downs of the applicable systems and components.

A master copy of the Unit 1 PSI Examination Plan containing all revisions will be maintained on-site by our examination agency, Southwest Research Institute. The Master Examination Plan will be available on-site for NRC inspection. Separate examination plans are currently being prepared for submittal to NRC that will address the balance of the Section XI PSI examination requirements not covered in the enclosed plan (i.e., eddy current examination of the steam generator tubing and visual examination of Class 1, 2, and 3 component supports).

The PSI examination plan for eddy current examination of the steam generator tubing is expected to be submitted to the NRC in September, 1985.

The PSI examination plan for visual examination of component supports is expected to be submitted to the NRC during the first quarter of 1986.

8509110118 850906 PDR ADOCK 05000498 A

PDR gi l N W2/NRC1/x L

g

Houston Ughting & Power Company ST-HL-AE-1343 File No.: T3.1 Page 2 If you should have any questions on this matter, please contact Mr.

M. E. Powell at (713) 993-1328.

Very truly yours, r

M. R.

senburg Manager, Nuclear Lic sing JSP:yd

Enclosure:

Unit 1 PSI Examination Plan L-W2/NRC1/x

ST-HL-AE-1343 File No: T3.1 Houston Lighting & Power Company Page 3 cc: w/o enclosure except as noted (*)

Hugh L. Thompson, Jr., Director J. B. Poston/A. vonRosenberg Division of Licensing City Public Service Board Office of Nuclear Reactor Regulation P.O. Box 1771 U.S. Nuclear Regulatory Commission San Antonio, TX 78296 Washington, DC 20555 Brian E. Berwick, Esquire Robert D. Martin Assistant Attorney General for Regional Administrator, Region IV the State of Texas Nuclear Regulatory Commission P. O. Box 12548, Capitol Station 611 Ryan Plaza Drive, Suite 1000 Austin, TX 78711 O

Arlington, TX 76011 Lanny A. Sinkin N. Prasad Kadambi, Project Manager 3022 Porter Street, N.W. #304 U.S. Nuclear Regulatory Commission Washington, D. C.

20008 7920 Norfolk Avenue Bethesda, MD 20814 Oreste R. Pirfo, Esquire Hearing Attorney Claude E. Johnson Office of the Executive Legal Director Senior Resident Inspector /STP U.S. Nuclear Regulatory Commission c/o U.S. Nuclear Regulatory Comission Washington, DC 20555 P. O. Box 910 Bay City, TX 77414 Charles Bechhoefer, Esquire Chairman, Atomic Safety & Licensing Board M. D. Schwarz, Jr., Esquire U.S. Nuclear Regulatory Comission Baker & Botts Washington, DC 20555 One Shell Plaza Houston, TX 77002 Dr. James C. Lamb, III 313 Woodhaven Road J. R. Newman, Esquire Chapel Hill, NC 27514 Newman & Holtzinger, P.C.

1615 L Street, N.W.

Judge Frederick J. Shon Washington, DC 20036 Atomic Safety and Licensing Board U.S. Nuclear Regulatory Commission Director, Office of Inspection Washington, D. C.

20555 and Enforcement U.S. Nuclear Regulatory Commission Mr. Ray Goldstein, Esquire Washington, DC 20555 1001 Vaughn Building 807 Brazos E. R. Brooks /R. L. Range Austin, TX 78701 Central Power & Light Company P. O. Box 2121 Citizens for Equitable Utilities, Inc.

Corpus Christi, TX 78403 c/o Ms. Peggy Buchorn Route 1, Box 1684 H. L. Peterson/G. Pokorny Brazoria, TX 77422 City of Austin P. O. Box 1088

  • Docketing &ServiceSection(3 copies)

Austin, TX 78767 Office of the Secretary i

U.S. Nuclear Regulatory Commission Washington, DC 20555 W2/NRC1/x Revised 5/22/85

- -