e The Light

~

c o m p a ny South Texas Project Electric Generating Station P. O. Box 289 Wadsworth, Texas 77483 g

gp September 5, 1996 ST-HL-AE-5464 File No.: T4.2,T5.2, T14.5,T20 10 CFR 50.55a U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 South Texas Project Unit 1 Docket No. STN 50-498 Unit 1 Sixth Refueling Outage Inservice Inspection Summary Report for Welds. Steam Generator Tubine and Component Sunnorts Enclosed are four copies of Inservice Inspection Summary Report, "lRE06 Inservice Inspection Summary Report for Welds, Steam Generator Tubes and Component Supports of the South Texas Project Electric Generating Station - Unit 1". This report describes the inservice inspection examinations performed between April 23,1996, and completion of the sixth refueling outage of South Texas Project Unit 1 (lRE06) on June 9,1996.

Inservice inspection examinations were performed on selected Class 1, 2 and 3 wiponents in accordance with the 1983 Edition of ASME Section XI Code with the Summer of 4983 Addenda and other regulatory and code bases as described in the "STPEGS-1 Ten Year ISI Plan". The enclosed summary report satisfies the reporting requirements ofIWA-6000 of Section XI for welds, steam generator tubes and component supports, and Sections 4.4.5.5 (b) and 6.9.2 of the South Tex. Project Technical Specifications with regard to steam generator tube inspection.

If you should have any questions on this matter, please contact either Mr. P. L. Walker at (512) 972-8392 or me at (512) 972-7162.

S. E. Thomas 9609200021 960905 Manager DR ADOCK 0500 8

Design Engineering

%'I PLW/lf

Enclosure:

1RE06 Inservice Inspection Summary Report for Welds, Steam Generator Tubes and Component Supports of the South Texas Project Electric Generating Station -Unit 1 j ggy g l f Misc.gr 4r,4.w Project Manager on Behalf of the Panicipants in the south Texas Project

?

,=

Houston Lighting & Power Company ST-HL-AE-5464 South Texas Project Electric Generating Station File No.: T4.2, T5.2 T14.5, T20 Page 2 c-

  • Leonard J. Callan Rufus S. Scott Regional Administrator, Region IV Associate General Counsel U. S. Nuclear Regulatory Commission Houston Lighting & Power Company 611 Ryan Plaza Drive, Suite 400 P. O. Box 61067 Arlington, TX 76011-8064 Houston, TX 77208
  • Thomas W. Alexion Institute of Nuclear Power Project Manager, Mail Code: 13H3 Operations - Records Center U. S. Nuclear Regulatory Commission 700 Galleria Parkway Washington, DC 20555-0001 Atlanta, GA 30339-5957
  • David P. Loveless Dr. Bertram Wolfe Sr. Resident Inspector 15453 Via Vaquero c/o U. S. Nuclear Regulatory Comm.

Monte Sereno, CA 95030 P. O. Box 910 Bay City, TX 77404-0910 Richard A. Ratliff Bureau of Radiation Control J. R. Newman, Esquire Texas Department of Health Morgan, Lewis & Bockius 1100 West 49th Street 1800 M Street, N.W.

Austin, TX 78756-3189 Washington, DC 20036-5869 M. T. Hardt/W. C. Gunst J. R. Egan, Esquire City Public Service Egan & Associates, P.C.

P. O. Box 1771 2300 N Street, N.W.

San Antonio, TX 78296 Washington, D.C.

J. C. Lanier/M. B. Lee J. W. Beck City of Austin Little Harbor Consultants, Inc.

Electric Utility Depanment 44 Nichols Road 721 Banon Springs Road Cohassett, MA 02025-1166 Austin, TX 78704 Central Power and Light Company ATTN: G. E. Vaughn/C. A. Johnson P. O. Box 289, Mail Code: N5012 Wadswonh, TX 77483

  • Above copies distributed without Attachments, except as noted by asterisk.