B11781, Forwards Environ Qualification of Mechanical Equipment, Supplemental Rept. Rept Updated to Include Conformance Review Sheets & Subcompartment Data Sheets for Remaining safety-related Mechanical Equipment

From kanterella
(Redirected from ML20133L674)
Jump to navigation Jump to search
Forwards Environ Qualification of Mechanical Equipment, Supplemental Rept. Rept Updated to Include Conformance Review Sheets & Subcompartment Data Sheets for Remaining safety-related Mechanical Equipment
ML20133L674
Person / Time
Site: Millstone Dominion icon.png
Issue date: 10/07/1985
From: Opeka J
NORTHEAST NUCLEAR ENERGY CO., NORTHEAST UTILITIES
To: Youngblood B
Office of Nuclear Reactor Regulation
Shared Package
ML20133L677 List:
References
B11781, NUDOCS 8510240256
Download: ML20133L674 (2)


Text

s N UTILITIES con.r.i Ovi.c... seio n sir i. Bernn. connecticut w cm sccun e =e w aecw =

P.O. 80X 270

. net wra ma cw

((((C,g" "

HARTFORD. CONNECTICUT 06141-0270 k

L J

(203) 665-5000 October 7,1985 Docket No. 50-423 B11781 Director of Nuclear Reactor Regulation Mr. B. 3. Youngblood, Chief Licensing Branch No.1 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C. 20555

References:

(1)

W. G. Counsil letter to B. 3. Youngblood " Environmental Qualification Report for Safety-Related Mechanical Equipment," dated January 14, 1985.

Dear Mr. Youngblood:

Millstone Nuclear Power Station, Unit No. 3 Environmental Qualification of Safety-Related Mechanical Equipment In Reference (1), Northeast Nuclear Energy Company (NNECO) provided information regarding the environmental qualification of safety-related mechanical equipment (the Report) located in harsh environment areas at Millstone Unit No. 3. The report has been updated to include the conformance review sheets and subcompartment data sheets for the remaining safety-related mechanical equipment that were not included in the original report.

The conformance review sheets list all equipment purchased under the specifications reviewed under this program and provide the qualification status for each. The subcomponent data sheets provide the listing of non-metallics used in each component evaluated and the results of the evaluation for that component. A revised copy of the master list is also included which shows the status of all safety-related mechanical equipment evaluated under this program.

I

! d

'f 8510240256 851007 PDR ADOCK 05000423 A

PDR

[

t

1 4.

. As requested by the NRC Project Manager for Millstone Unit No.

3, Ms. E. L. Doolittle, ten (10) copies of this report are being forwarded directly to her. if there are any questions regarding this submittal, please contact our licensing representative directly.

Very truly yours, NORTHEAST NUCLEAR ENERGY COMPANY et.al.

BY NORTHEAST NUCLEAR ENERGY COMPANY Their Agent 0n$u--

J. F. OpeWa U

Senior Vice President STATE OF CONNECTICUT )

) ss. Berlin COUNTY-OF HARTFORD

)

Then personally appeared before me J. F. Opeka,.who being duly sworn, did state that he is Senior Vice President of Northeast Nuclear Energy Company, an Applicant herein, that he is authorized to execute and file the foregoing information in the name and on behalf of the Applicants herein and that the statements contained in said information are true and correct to the best of his knowledge and belief, hh 1/nt

/

h!/ P'

/

Motary Puby My Commission Expires March 3f,198g m