Responds to NRC Re Violations Noted in Insp Rept 50-458/85-12.Corrective Actions:Five Calculations Not Signed Off by Reviewer Reviewed & Approved,All Seg Structural Calculations Reviewed & Requirements Reemphasized
ML20128M959
Person / Time
Site: River Bend 
Issue date: 05/08/1985
From: William Cahill
GULF STATES UTILITIES CO.
To: Martin R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20128M956 List:
References
RBG-20934, NUDOCS 8506030130
Download: ML20128M959 (5)


Text

{

o 4

Ye2 GULF STATES UTILITIES COMPANY RfvER BEND STATION -

POST OFFICE 80x 220

$ f. FRANCISVILLE. LOUISIANA 70775 AREA CODE 604 635 6094 346-8661 May 8, 1985 RBG-20934 File Nos. G9.5, G15.4.1 Mr. Robert D. Martin, Regional Administrator 5-U. S. Nuclear Regulatory Commission

$@$0 Region IV 611 Ryan Plaza Drive, Suite 1000 g

Arlington, Texas 76011 8

Dear Mr. Martin:

J River Bend Station - Unit 1 Refer to: Region IV Docket No. 50-458/ Report 85-12

- This is in response to the Notice of Violations contained in NRC ISE Inspection. Report No. 50-458/85-12. The inspection was performed by Messrs.

W. M. McNeill, I. Barnes, and W. R. Bennett during the period February 25 - March 1, 1985, of activities authorized by NRC Construction Permit CPPR-145 for River Bend -

Station Unit No. 1.

Gulf States Utilities Company's.(GSU) response to the Notice of Violations 85-12-01, " Independent Review of Design Change Cal-culations," and 85-12-02, " Control of Temporary Alterations," is provided in the enclosed attachment. This completes GSU's response to the Notice of Violations.

Sincerely,

,/

W. J. Cahill, Jr.

Senior Vice President River Bend Nuclear Group WJC/P[JD/TCC/TFP/amg (d

t 4W

-Attachment O

850528 05000458 PDR yC - 0%/&S-

!L

  • ATTACHMENT May 8, 1985 RBG-20934

' Response to Notice of Violations Reference Notice of Violation - E. H. Johnson letter to W. J. Cahill, dated. April 8, 1985.

Refer to Docket No. 50-458/85-12.

1.

Response to 85-12-01 Independent ^ Review of Design' Change Calculations

' Corrective Steps Which Have Been Taken~and the Results Achieved a.

The NRC Inspector reviewed 53 Engineering Mechanics Division (EMD) calculations and identified three calculations which had not been signed off by an independent reviewer. A subsequent Engineering Assurance surveillance reviewed 471 additional calculations and identified two calculations which had not been signed off by an independent reviewer. Thus, five calculations were identified out of a total sample of 534 calculations.

Only one of the five calculations identified had been processed after implementation of the preventative action associated with Engineering Assurance audit A0-12210-195 conducted on October 12, 1984, which reported a similar problem.

The five calculations identified have been reviewed and approved.

b.

A sample review of the structural calculation books examined by the NRC indicated that approximately six percent of all calcu-lation pages did not exhibit an "I" next to the reviewer's signature or the independent reviewer's signature.

A 100 percent review of all SEG structural calculations was subsequently performed. Where any deficiency was noted, the independent review was appropriately documented and reflected in calculation files.

Corrective Steps Which Will Be Taken to Avoid Further Violations a.

The requirements of Engineering Assurance Procedure (EAP) 5.3 were reemphasized to all applicable EMD engineers during a meeting conducted March 5, 1985.

No further corrective action will be implemented since each EMD calculation is subject to a final design verification i

process. This process will ensure the reconciliation of all installed hardware to the approved design base.

i

g L,

Page 2 May 8, 1985 RBG-20934 b..

The requirements of Structural Technical Procedure 11.5 and EAP-5.3 were reemphasized.to all applicable.SEG Structural. Engineers and documented training was performed'on April 15, 1985.

Date'When Ful1~ Compliance Will Be Achieved

a.. Full compliance will be achieved by fuel load.

.b.

. Full compliance was achieved by May 1, 1985.

i

r Page 3 May 8, 1985 RBG-20934 2.

Response to 85-12-02 Control of Temporary Alterations Corrective Steps Which llave Been Taken and the Results Achieved Corrective action was taken immediately and in the presence of the NRC Inspector to bring temporary alteration 85EGS-009 into compliance with River Bend-Startup Manual Test Instruction No. 17.

The temporary alteration log was then audited by the GSU Project

' Quality Test Group (PQTG). The audit was completed by March 31, 1985, and the minor discrepancies identified by the PQTG have been corrected to ensure compliance with Test Instruction No. 17.

Corrective Steps Which Will Be Taken To Avoid'Further Violations GSU's Startup and Test Group has. assigned dedicated personnel to assure that procedural compliance is maintained. These personnel will control entries to the temporary alteration log and verify correct installation and/or removal of temporary alterations.

Date When Full Compliance Was' Achieved Full compliance was achieved by April 30, 1985.

1 y

UNITED STATES OF AMERICA NUCLEAR EEGULATORY CGetISSION STATE OF LOUISIANA 5

PARISH OF WEST FELICIANA 5

In the Matter of 5

Docket Nos. 50-458 CULF STATES UTILITIES COMPANY 5

(River Bend Station, Unit 1)

AFFIDAVIT W.

J.

Cahill, Jr.,

being duly sworn, states that he is a Vice President of Culf States Utilities Company; that he is authorized on the part of said Company to sign and file with the Nuclear Regulatory Commission the documents attached hereto; and that all such documents are true and correct to the best of his knowledge, information and belief.