W3P84-0505, Forwards Evaluation of Natural Circulation Cooldown Test Performed at San Onofre Nuclear Generating Station. Boron Mixing Tests in Lieu of Natural Circulation Test Accepted by Updated SER & Sser 5

From kanterella
(Redirected from ML20080U487)
Jump to navigation Jump to search
Forwards Evaluation of Natural Circulation Cooldown Test Performed at San Onofre Nuclear Generating Station. Boron Mixing Tests in Lieu of Natural Circulation Test Accepted by Updated SER & Sser 5
ML20080U487
Person / Time
Site: Waterford, San Onofre, 05000000
Issue date: 02/29/1984
From: Cook K
LOUISIANA POWER & LIGHT CO.
To: Knighton G
Office of Nuclear Reactor Regulation
Shared Package
ML20080U490 List:
References
W3P84-0505, W3P84-505, NUDOCS 8403020333
Download: ML20080U487 (1)


Text

I

/

' LO U I SI ANA f 4.. oe-o~oe erae.1

.o oOx eOOe POWE11 & LIGHT / NEW CALEANS LOUSANA 70174 4000

. (504)368-234S MfDDLE COUTH UTILITIES SYSTEM February 29, 1984 W3P84-0505 3-A1.01.04 3-A37.02 Director of Nuclear Reactor Regulation Attention: Mr. G.W. Knighton, Chief Licensing Branch No. 3 Division of Licensing U.S. Nuclear Regulatory Commission Washington, D.C. 20555

SUBJECT:

Waterford SES Unit 3 Docket No. 50-382 Natural Circulation Cooldown/ Boron Mixing

Dear Sir:

In lieu of performing a natural circulation test to demonstrate adequate boron rlxing, LP&L referenced the boron mixing tests to be performed at the San Onofre Nuclear Generating Station (SONGS). This position was foeud acceptable by the Staff in the Waterford SER, and fifth Supplement to the SER (section 5.4.3).

The boron mixing tests have been completed at SONGS. LP&L participated in a CE Owners Group effort to evaluate the SONGS results and demonstrate applicability to Waterford 3.

Enclosed please find four copies of CEN-259, An Evaluation of the Natural Circulation Cooldown Test Performed at the San Onofre Nuclear Generating Station. The Owners Group work has confirmed the acceptability and cpplicability of the SONGS results to Waterford 3.

Should-you have any questions or comments in this matter please contact Mike Meisner at (504) 363-8938.

Yours very truly.-

K.

W.' Cook:

Nuclear Support & Licensing Ma' nager KWC/MJM/ch

. Enclosure cc:

W.M. Stevenson, E.L. Blake, J. Wilson, G.L. Constable (Yh-0 8403020333 840229

'\\A PDR ADOCK 05000382

\\

N A

PDR

_ -