o.

F"C'~I? T 4

l j M MISSISSIPPI POWER & LIGHT COMPANY U <j' Help ong i usta !.:::s is :1.7 v,

29 6 ar.5 D.C. BOX 16 4 0 J A C r. E O f.. MISC.;J'PPI 39205 nutt a n t w.,:nc nu. wowtra Septcmber 5, 19S0

~

l Office of Inspection & Lt.forecacnt U. S. Nuclear hc:guintory Co:: lesion Region II 101 Marietta Street, I.~4 Suite 3100 Atlanta, Georgia 30303 Attention:

Mr. J. P. O'Reilly, Director

Dear Mr. O'Reilly:

SUBJECT:

Grand Gulf Nucicar Statica l' nits 1 and 2 Dochet Nos. 50-416/417 File 0260/15525/15526 PRD-80/'.7, Interim Report l'1 Supplier ' Tawing hevision Lotice Prograr.

AEC4-SO/207 On August 6, 1980, Mississippi Power 6 Light actified Mr. M. Hunt of yccr office of Potentially Repertable Deficiency (PRD) at the Grand Gulf Nuc1(cr Station construction site. The deficiency concerns the inadequate centrol cf Supplier Drawin;; Revisien Notices (SDRN) Pror,rc:a.

Attached is an inter b report.

We expect to. complete our investigation and subit a complete report by January 22, 1981.

Yours truly, 24 #

c/

f

[pr' J. P. McGaughy, Jr.

Assistant Vice President, Nuclear Preduction ATR:1b-cc:

Mr. N. L. Stampicy Mr. R. B. McCchee Mr. T. B. Conner Mr. ' Victor. Stello, Director 4 THIS COPY r0P Division of Inspection & Enforcement

'U. S. Nucicar Regulatory Commission g/ f Washingtoi. D. C.

20555i vj i

-s 80091501e/

Member Middle South Utilities System

I Attach at A to AECM-50/207 Pa ;,<_ 1 af 1 Interir! Report f/1 t o PP.I;- 30 / '4 7 1.

Potentio! Problen inadegnte control cf the Suppliar Drawing; Revisien Sotice (SD L)

Progrnt has caused the status of affected equipment, (incorporation of SD70's; to be inde t er:-ir.a t e.

11.

knraach to Resolution of Problem A.

Pc; fern investi;;ative actions to identil/ noncen orr.ir;t conditions; A cure:;:. evaluate, and dispasition each ne r. conf ormr;'u.

it.

Review and revise procedural controls wta"lished inr the SDPJ: P ro r, ram.

cf Prop: sed Resclution

.III.

Ftatu e A.

Investir,ative action to date has resulted ir. the issuance c f

.anconforaance documents.

Evaluatian ::+ d ater=ir.e safety

+

implicatians is in process.

PrcceJ.ures covering the costrol c: SP3's have ocen revised.

In -idditien, a special method has been de. ised f er SDPJ' revie" and nunch listing to permit systcr turnever en a casc h case basis.

IV.

Recsers for Dela" of Final Report Investigstive action has not been completed.

of Corrective Action anc' Submittal Date of Coe,lete V.

P.ro,j ect ed Ceepletion a

Rep rt Corrective Active are expected to be completed by December 18, 1980.

Submittal date of complete report is projected for January 22, 1981.