Exelon Generation RS-20-012 January 29, 2020 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Braidwood Station, Units 1 and 2 4300 Winfield Road Warrenville, IL 60555 630 65 7 2000 Office 10 CFR 50.55a Renewed Facility Operating License Nos. NPF-72 and NPF-77 NRC Docket Nos. STN 50-456 and STN 50-457

Subject:

Response to Request for Additional Information Regarding Relief Request Associated with the Third Ten-Year lnservice Inspection Program Interval

References:

1. Letter from D. Murray (Exelon Generation Company, LLC) to U.S. NRC, "Relief Request Associated with the Third Ten-Year lnservice Inspection Program Interval," dated August 27, 2019(ML19239A156)
2. Email from J. Wiebe (U.S. NRC) to L. Palutsis (Exelon Generation Company, LLC), "Draft Request for Additional Information Regarding Braidwood Station, Units 1 and 2, Impractical lnservice Inspection Requirements (L-2019-LLA-0081 ),"dated December 16, 2019 (ML19350B295)

In Reference 1, Exelon Generation Company, LLC (EGC) submitted relief request 13R-18, for Braidwood Station (Braidwood), Units 1 and 2. The proposed request is associated with the Third 10-year lnservice Inspection (ISi) Program Interval for Braidwood Station, Units 1 and 2.

The third interval of the Braidwood Station ISi program complies with the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code,Section XI, "Rules for lnservice Inspection of Nuclear Power Plant Components," 2001 Edition with 2003 Addenda and ASME B&PV Code,Section XI, 1998 Edition subject to conditions specified in 10 CFR 50.55a(b)(2)(xxi).

In Reference 2, the NRC requested additional information that is needed to complete the review of the proposed relief request. In response to this request, EGC is providing the additional information requested in Attachments 1 through 6.

Additionally, EGC is submitting corrections to Reference 1Tables13R-18.1and13R-18.2 in.

U.S. Nuclear Regulatory Commission January 29, 2020 Page2 There are no regulatory commitments contained in this letter. Should you have any questions concerning this letter, please contact Mrs. Linda Palutsis at (630) 657-2821.

Dwi Murr Sr. Manager Licensing Exelon Generation Company, LLC Attachments:

cc:

1. Additional Information Supporting 1 0 CF R 50. 55a Relief Request 13 R-18

2. Examination Datasheetsfor 1PZR-01-N1, 1PZR-01-N4A, 2PZR-01-N1, 2PZR-01 -N48, and 2PZR-01-N4C
3. Examination Datasheets for 2SG-01-SGN-01A
4. Examination Datasheets for 2SG-01-SGC-02
5. Examination Datasheets for 1 Sl-39-25
6. Examination Datasheets for2AF-01-24 (FW-3), 2AF-01-25 (FW-4), 2AF-02-23 (FW-1),

2AF-02-24 (FW-2), 2AF-03-23 (FW-1 ), 2AF-03-24 (FW-2), 2AF-04-20 (FW-3),

2AF-04-21 (FW-4), 2CV-21-56 (FW-2), 2CV-21-57 (FW-2), 2CV-21-58 (FW-1), and 2FW-09-25

7. Correcied Tables 13R-18.1and13R-18.2 NRC Region Ill, Regional Administrator NRC Senior Resident Inspector, Braidwood Station NRC Project Manager, Braidwood Station Illinois Emergency Management Agency - Division of Nuclear Safety

ATTACHMENT 1 Additional Information Supporting 10 CFR 50.55a Relief Request 13R-18 In reviewing the Exelon Generation Company, LLC's (EGC) submittal dated August 27, 2019 (ADAMS Accession No. ML19239A156), related to its request under Title 10 of the Code of Federal Regulations (10 CFR) 50.55a(g)(5)(iii) for relief on the basis that achieving the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) inservice inspection (ISi) requirements is impractical for the Braidwood Station (Braidwood),

Units 1 and 2, the NRC staff has determined that the following information is needed in order to complete its review.

RAl-1:

The information provided in the August 27, 2019, submittal regarding the pressurizer shell-to-nozzle welds (Category B-D, Item Number B3.110) identify their material construction as Alloy 82/182. The August 27, 2019, submittal also shows these to be welds between the low alloy steel shell of the pressurizer and low alloy steel nozzle forgings. Without additional clarifying information, the NRC staff is unable to evaluate the impracticality of meeting the ASME Code requirements, whether alternatives should be imposed, and whether an augmented inspection program or other action is needed for added assurance of structural reliability. The licensee is requested to:

1. Confirm that the pressurizer shell-to-nozzle welds (Category B-D, Item Number B3.110) are, in fact, Alloy 82/182 welds.
2. Confirm that there is an Alloy 52/152 weld overlay on the Braidwood, Unit 1 weld 1 PZR-01-N4A.
3. If the pressurizer shell-to-nozzle welds (Category B-D, Item Number B3.110) are not fabricated from Alloy 82/182 material, provide the inspection results (i.e., whether reportable indications were found) in response to this question.

RESPONSE

1. The pressurizer shell-to-nozzle (Category B-D, Item Number B3.110) weld material is E-9018 and the weld does not contain Alloy 82/182 weld material.
2. There is no Alloy 52/152 overlay on Braidwood Unit 1weld1PZR-01-N4A.
3. No flaws or defects were identified during the examinations. Attachment 2 provides the complete examination results for 1PZR-01-N1, 1PZR-01-N4A, 2PZR-01-N1, 2PZR N4B, and 2PZR-01-N4C.

Additionally, EGC is submitting corrections to Tables 13R-18.1 and 13R-18.2 in Attachment 7.

This attachment replaces the tables provided in Reference 1 in its entirety. In addition to correcting the material of construction, the new tables indicate whether all examinations were inservice inspection of pre-existing welds (ISi) or preservice examination of new welds (PSI),

provides examination results summaries for all examinations, and corrects the "Appendix VIII Qualified Examination" indication column for Category B-D and C-A examinations. The Examination Category B-D and C-A components were examined in accordance with Section V, Article 4 as amended by Section XI, Appendix I rather than Appendix VIII techniques.

Page 1 of 5

RAl-2:

ATTACHMENT 1 Additional Information Supporting 10 CFR 50.55a Relief Request 13R-18 The information provided in the August 27, 2019, submittal regarding the pressurizer shell-to-nozzle welds (Category B-D, Item Number B3.110) identify their material construction as Alloy 82/182. Historically, Alloy 82/182 (lnconel) welds in pressurized water reactors are susceptible to primary water stress corrosion cracking (PWSCC). Without additional clarifying information, the NRC staff is unable to evaluate the impracticality of meeting the ASME Code requirements, whether alternatives should be imposed, and whether an augmented inspection program or other action is needed for added assurance of structural reliability.

The licensee is requested to provide the inspection results (i.e., whether reportable indications were found) for the third 10-year ISi interval examinations of the Category B-D welds addressed in Tables 13-R18.1and13-R18.2 of its August 27, 2019, submittal. Since these welds are identified as having been fabricated from Alloy 82/182 material, the license is requested to justify the limited coverage obtained to date on these welds with a technical evaluation that addresses the susceptibility to PWSCC. If inspections of similar Category B-D lnconel 82/182 welds were performed during the third 10-year ISi interval, a summary of the inspection results for those welds is requested. If additional Alloy 82/182 welds were not examined, the justification should include an explanation for not examining additional or alternative accessible welds in Category B-D.

In addition, if applicable based on the answer to RAl-1, provide the results of the Braidwood, Unit 1, 1 PZR-01-N4A examinations that were performed prior to the weld overlay and the results of subsequent examinations of the weld overlay including the examination results performed during the third ISi interval.

RESPONSE

The Category B-D welds do not contain Alloy 82/182 weld material. No flaws or defects were identified during examinations of these components. Attachment 2 provides the completed examination results for 1PZR-01-N1, 1PZR-01-N4A, 2PZR-01-N1, 2PZR-01-N4B, and 2PZR-01-N4C. No evaluation to address the susceptibility of PWSCC was performed as the welds are not lnconel 82/182 and not subject to PWSCC.

As identified in RAl-1, there is no Alloy 52/152 overlay on Braidwood Unit 1 weld 1 PZR-01-N4A.

In addition, Attachment 3 provides the completed examination results for 2SG-01-SGN-01A.

This component is part of the Category B-D population.

RAl-3:

Provide examination results of the low alloy steel weld 2SG-01-SGC-02, which is a Tube Sheet to Barrel weld Category, C-A, Item Number C1.30, for Braidwood Unit 2. Without this additional information, the NRC staff is unable to evaluate the impracticality of meeting the ASME Code requirements, whether alternatives should be imposed, and whether an augmented inspection program or other action is needed for added assurance of structural reliability.

Page 2 of 5

RESPONSE

ATTACHMENT 1 Additional Information Supporting 10 CFR 50.55a Relief Request 13R-18 No flaws or defects were identified during examinations of this component. Attachment 4 provides the complete examination results for weld 2SG-01-SGC-02.

RAl-4:

Braidwood, Unit 1weld181-39-25 is identified as having received a limited examination (i.e. only 50% of the required examination volume was examined), and two flaws were identified. Given this information, provide justification that the structural integrity of Braidwood, Unit 1 weld 1 Sl-39-25 is assured. Without additional information, the NRC staff is unable to evaluate the impracticality of meeting the ASME Code requirements, whether alternatives should be imposed, and whether an augmented inspection program or other action is needed for added assurance of structural reliability.

RESPONSE

Figure 1 below, provides the flaw indication plot for the subsurface (embedded) flaw for the preservice examination of weld 1 Sl-39-25. Indications 1 and 3 on the plot are the same flaw with Indication 1 detecting the flaw in the downward 45-degree angle and Indication 3 detecting the same flaw in the upward direction after bouncing off the inside diameter surface.

Indication 2 is an inside diameter geometric reflector and not indicative of a material discontinuity.

INDICATION PLOT SHEET PLANT z~.

UNIT

_1_

TRANSDUCER 008HOP EXAMINER

  • ~J~Jfi serdt level iicana:J<1~~ng5_ le'?ei ii FREQUENCY 2.25 08"' Sheet No. A1R1&-029 Page _ 5_

ol

...L_

ANGL

~45_

SIZE Al.IB~ION BLOCK 22572 WELDIO#

FW*25JSI DATE ___

4;::..:./1612=012:___ __

II"

\\'"

r 0

r Figure 1. Indication Plot Sheet for the Preservice Examination of Weld lSI-39-25 Page 3 of 5

ATTACHMENT 1 Additional Information Supporting 10 CFR 50.55a Relief Request 13R-18 The Performance Demonstration Initiative (POI) piping examination procedure is only qualified for two-sided flaw detection in austenitic stainless-steel welds. The weld is a stainless-steel elbow-to-valve weld and the valve configuration allows examination from only one side, therefore only 50% coverage may be credited. The examination procedure is often capable of detecting flaws on the far side of a weld as has been demonstrated in the case of the flaw in weld 1 Sl-39-25. The flaw was detected with 45-degree and 60-degree shear wave examination techniques, but not the 60-degree or 0-degree longitudinal wave examination techniques. The flaw was less than the preservice examination acceptance standards of IWB-3514 and was not detected by the Section Ill radiography examination. Based on these observations the flaw is most likely a small welding fabrication flaw.

Based on the existence of the small weld fabrication flaw observed during the preservice examination, it is unlikely similar flaws or unacceptable flaws are present in the required Section XI examination zone because:

1. The weld received construction code required radiography and no flaws were observed.

Radiography is a reliable NOE method for examination of welds for construction quality requirements.

2. There were no other flaws detected by the ultrasonic testing (UT) which examined additional volume on the far side of the weld (volume which could not be credited with coverage based on POI qualification limitations). Figure 2 provides a plot of UT examination coverage which indicates all the Section XI required weld material was interrogated with UT examination techniques.

~ ' J~~pync; UL TR.\\ 0 IC EX,\\ llK ; roN SJJ:TCH SHEET

,.-*--~

Plam/ Uni1 :

--~

""'~ld~.000'=:-l=

t __ Comp / Sysiem FW* 251SI b o. o.... *g:

tSl-39 ISI Weld COMMENTS:

FW*25 I SI-3'l-Z5 REVIE.\\VfR:

r..u......

'~

Pnm J~u J k:flnirhi:i lJiZ)

--~J_~\\.-.~""=~--OATE ft\\ 1-'\\'k O:ua Pl.y *. A 1\\

Ol~

P eh ofB l\\ Ill DATE

-ll"IL Figure 2. Ultrasonic Examination Sketch Sheet for Weld lSI-39-25 Page 4 of 5

ATTACHMENT 1 Additional Information Supporting 10 CFR 50.55a Relief Request 13R-18 Based on the IWB-3514 preservice acceptance standard acceptability of the flaw, there is no required subsequent examination per Section XI or need for augmented examinations for this Class 2 weld. The examination limitation is essentially identical to all austenitic stainless-steel elbow-to-valve welds in the nuclear industry where valves limit examination access to one side of the weld. Attachment 5 provides the UT report for weld 1 Sl-39-25, including Figures 1 and 2.

Several of the NOE reports in Attachment 3 for Category R-A welds did not include the examination results. Provide the examination results for the following Category R-A welds for Braidwood Unit 2. Without this additional information, the NRC staff is unable to evaluate the impracticality of meeting the ASME Code requirements, whether alternatives should be imposed, and whether an augmented inspection program or other action is needed for added assurance of structural reliability.

2FW-09-25, 2AF-03-23 (FW-1 ), 2AF-03-24 (FW-2), 2AF-04-20 (FW-3), 2AF-04-21 (FW-4), 2AF-02-23 (FW-1), 2AF-02-24 (FW-2), 2AF-01-24 (FW-3), 2AF-01-25 (FW-4), 2CV-21-58 (FW-1),

2CV-21-57(FW-2), and 2CV-21-56(FW-2).

RESPONSE: includes the completed examination results for the welds listed below. includes a summary of the examination results in the "Remarks" column.

2AF-01-24 (FW-3) 2AF-01-25 (FW-4) 2AF-02-23 (FW-1) 2AF-02-24 (FW-2) 2AF-03-23 (FW-1) 2AF-03-24 (FW-2) 2AF-04-20 (FW-3) 2AF-04-21 (FW-4) 2CV-21-56 (FW-2) 2CV-21-57 (FW-2) 2CV-21-58(FW-1) 2FW-09-25 Page 5 of 5

ATTACHMENT 2 Examination Datasheets for 1 PZR-01-N1, 1 PZR-01-N4A, 2PZR-01-N1, 2PZR-01-N48, and 2PZR-01-N4C

~

Ext;;"on,.

UT Calibration..amination Sie/Unit:

llRW 1

Procedure:

EXE.fSl-210 Outage No.:

A1R19 S inmary No.:

1-803.110.0015 Procedure Rev.:

'FCN.-1 Report No.:

A1R11.uT~

-~--~~~~~~~~--

Worksc:ope:

ISi Wodc Order No.:

01839513-411 Page:

1 or 5

Code:

ASME XI, 2001 Ed, 2003 Ad Cat.lltem:

B-DIB:l.110 Location:

sonoM PZR,R-GI Drawing No.:

1PZR.01 Oesaiplion: PRESSURIZER - SURGE NOZZLE System ID:

RY


~

Compo11e11t IO:

1PZR.01.f41 Sizell.ength:

1.39182.0-ThiclcnesslOlam 3.1* 114*

l.imitalions:

Nozzle8ore start Time:

1631 Finish Time:

1737 lnsln.unent SeCtlngs Sell'd'IUnil cai.

Axial Oriented Sean:b Unit Time o.te Serial No.:

SAP 104766 Serial No.:

01BXY7 Checlcs lnilial car.

calibration Signll Sweep Sound Patti Manufaclurer:

GEIT Manufacturer:

KB-Aerotech 1347 lll30l201&

Retlec:tor Ampllude'lli Oiviaion Model:

USNSILSW Ururity:

201M..-1 Size:

uo*

Model:

Gamml Inter. cal.

1631 913012016 ur TSDH 80%

u 0.675"'

Delay:

0.1138 ps Range:

uoo*

Inter. cal.

NIA 112* TSDH 41%

,.1 1M'"

Freq.:

2.25 MHz Center Freq.:

NIA M"ll CalNel:

0..2330 INflJs Pulser Type:

Square Inter. Cal.

NIA 314*TSOH 2ft 6.2 z.1r EJCam Angle:

O" Squint Angle:

NIA Final Cal.

1915 9/3012011 Damping:

5000hms Reject O'lli Measured Angle: __.!:__ Mode:

Long CouplaAI PRF:

Auto High SU Freq.:

2.25 MHz E>cil Point NIA

  1. of Elements: ~

Cal. Batch:

Frequency:

2.25MHz Rectify:

FUllWaW 186115 Ciraanl'erential Oriented 5ffrch Unit Config.:

Single Focus:

NIA Voltage:

450 PlAsaWldtl'I:

220 Type:

Ultqgel II Calibration Signal Sweep Sound Palh Shape:

ROWld Contour:

FLAT Refledor Amplilude'lll Division Mfg.:

Sonotech sws NIA Wedge Style:

Exam 8ltcl'I:

18G015 NIA NIA NIA Ax. Gain (dB):

2.9 Circ. Gain (dB):

NIA 1

Screen Div. =

0.35 in. of SoundPllth Calibration Blocll Cal. Blocll No.:

BWD-071 TNclcness:

u-Dia.:

Flat Cal. Bit. Temp.: !!!_ Temp. Tool:

SAP108896 Comp. Temp.:.!!:!. Temp. Tool:

SAP1"896 lndicatio11(s)

Remis:

Accept ~

0 Reject 0

~

Percent Of Coverage Oblained > 90'llo:

7,.7..

Examiner Level Steinbauer, Troy Examiner Level NIA NIA Other Level NIA NIA RS-20-012 Attachment 2 search unil cable Type:

Ultragel II Type:

RG-17' Lengtl'I: ~

No. Conn.: 0 Mfi.

Sonotech g..

Scan Coverage Upstream~ Downstream~ Scan dB:..!:!.._

Reference 8loc:fc ReferencelSimulator Block Gain Signal Sweep cwo CCW0 ScandB: NIA Serial No.:

SAP 105633 CS dB Relleclor.

'Iii Division Sound Pall Exam Surface:

OD

-- Type:

CSSStep o.o 3.0 IO'lli 2.19*

Surface Condition:

Ground Flush 0.0 2.0 IO'lli S.7 z.o*

eport.)

lnlo 0 Commenls: Scanned 100% of weld volume. See Comments on Page'-

Dose: 23mr.

Reviewed Previous Data:

Yes Date' RIM!Mr 9/30/2016 Delbusso, James Level II Dale Signalure Date Signature

~

Date 9/30/2t1' Dafll

/0-1.-/t.

Date

/tJ*o1*.MI~

Page 1

...-r

~

Exetony UT Calibration *.. amination Code:

Site/Uni:

BRW 1

S mmaiy No.: -------------

1-803.110.0015 Workscope:

ISi ASME XI, 2001 Eel. 20m Ad Cal./ltem:

Procedure:

Procedure Rev.:

Work Order No.:

&:ol83.110 EXE-U;l-210 4 FCN-001 01839513-01 Location:

Drawing No.:

1PZR-411

==

Description:==

PRESSURIZER

  • SURGE NOZZLE Sy&temlD:

RY C>uageNo.:

A1R19 Report No.:

A1R19.uT.023 Page:

2 af 5

BOTTOM PZR,R-OI Component ID:

-1~PZ~R~.0-1_.a_1---------------------------------------------------------~

Sizell.ength:

1~*112A*

Start Tame:

TliclcnesslDilm:

3.1* 114*

Umilations:

Nozzle Bore 1631 Finish Tune:

1737 Instrument Settings Search Unit Cal.

Alial Oriented Search Unit Tune Dille Serial No.:

SAP104788 Serial No.:

H25005 Chedls Manufacturer:

Initial Cal.

1344 C8libratian Signal SWeep Sound Path GEIT Manufacturer:

KB-Aerotech 9/3Cll2016 Reflector

~

OMsion Model:

USN5a.SW Linearity:

2011-L-007 Size:

o.so* x 1.0-Modal:

Gamma 1.ar. Cal.

1658 9l30/2018 114.TSOH SR 2.0 1.01*

Delay.

10.9091 I'S Range:

5.25*

Freq.:

2.26MHz Center Freq.:

NIA llUr.Cal.

NIA 112*TSDH 70%

'-0 2.05*

M'U Cal/Vet 0.1270 inll's Pulser Type:

Squse ExamAngle:

w Squint Angle:

NIA Inter. Cal.

NIA 314.TSDH 4ftt 6.0 u-Damping:

SOOOhms Reject:

0%

Final Cal 1917 913012016 514*TsDH 20%

10.0 NIA Measured Angle: ~

Mode:

Shear PRF:

/Jd.oHigh SU Freq.:

2.25MHz Exit Point:

o.es*

II of ElementS:

Couplant IDNolch

~

8.7 4.S-1 frequency:

2.25MHz Rectify:

FullWave Config.:

-- Cal Batch:

166015 Circumferential Oriented Sean:h Unit Single Focus:

NIA Voltage:

450 PulseWdh:

220 Shape:

Rect.

Contour:

Flat Type:

Ultr119el II caJibndion Signal SWeep Sound Patti Reflector Amplitude'lli DiYilion Mfg.:

Sonotech Wedge Style:

sws NIA NIA NIA NIA Ax. Gain (dB):

29.8 C". Gain (dB):

NIA Sean:h Unit Cable ExamBalch:

160015 1

Screen Div...

0.525 in. of Sound Path Type:

RG-174 length: 12' No. Conn.: 0 Type:

Uftragel 11 Mfg.:

Sonotech Calibration Block Scan COYerage Cal. Block No.:

~71 Upstream~ Downsaream ~ Scan dB: ~

Reference Block ReferencelSimulator 8lodc Thickness:

3.1*

Ola.:

Flat Gain Signal SWeep cw~

ccw~ Scan dB: 35.8 Serial No.:

SAP 103480 CS dB Reflector Amlllitude.. DMsion Scund Path Cal. Blk. Temp.: !!.!, Temp. Tool:

SAP10&896 Exam Surface:

00 Type:

1* Angle Beam 21.4 FSDH...

3.8 2.8Z-Comp. Temp.: !!:f Temp. Tool:

SAP106896 SUrface Condiion:

Ground Flush 21A NSDH 14%

1.9 1.01*

Record.able lndication(s):

veso No~

(If Yes. Ref. Attached UllraSOnic lnclcaliOn Report.)

Results:

Acc:ept ~

Reieet D Info 0 Commenls: See Camments on Page'-

Percenl Of Coverage Oblained > 90'lli:

74.7%

Elcaminer level U-PDI stelnbauer, Troy Examiner Level NIA NIA Other Level NIA NIA RS-20-012 Attachment 2 Reviewed PnMous Data:

Yes Dale I Reviewer 9/30/2016 Delbusso. ames LeYet w Dale I Site Review

... ~

r-~'""~

Signature Date I ANll Review At:/_,_.,,,. ({..,:,.

Date 91301Z016 Dale IO*C.-IC.

Date

/J*O"I*~"'

Eaga.2

~Exelon.

UT Calibration..amination SitelUnil: _

__;;,,~~------~

BRW I

1 Procedure:

EXE-ISl-210 OllageNo.:

A1R19 1as.110.001s SwnmatyNo.: ------------

Procedure Rev.:

4 fCN.001 Report No.:

A1R1MIT.OD Worksc:ope:

ISi Work Order No.:

01839513-41 Page:

3 of 5

Code:

ASME XI, 2001 Ed, 20113 Ad cat./ltem:

B-DIB3.110 Loc:alion:

BOTTOM PZR.R.ol Drawing No.:

1PZR-01 Desc;riplian: PRESSURtZER - SURGE NOZZLE System ID:

RY -----------------------------------------------------------------------------------------------------------------

Componei d ID:

1PZR.01.J<l1 ThicknesslDilme

1.1*114*

Size/length:

u* I 82.o*

StaltTtme:

Llmitallons:

Nozzle Bore 1631 Finish Time:

1737 Instrument Settings Search Unit cat Axial Orienled Surch Unit Date Serial No.:

SAP104766 Serial No.:

009Y45 Checks CalbratiDn Initial Cal.

Signal sweep Sound Path Manufacturer; GST Manufacturer:

K~olecll 13'9 9/30l2016 Reflector AmpllUdellll Division Model:

USN58LSW Unearity:

2016-1...007 Size:

o.so* x 1.0*

Model:

Gamma Inter. Cal.

1730 9/30l2016 1/irTSDH 80%

2.0 u*

Delay:

15.700 I'S Range:

1.soo*

Freq.:

2.25MHz center Freq.:

NIA Inter. Cal.

NIA 1/TT SOH 52%

4.11 3.0*

M'll CalNel:

0.1270 lnlps Pulser Type:

Square E>eam Angle:

w Squint Angle:

NIA Inter. Cal.

NIA 314*TSDH 35%

6.0 4.s*

Final Cal.

1911 9130/2016 514*TsDH 19%

10.0 NIA Damping:

SOOOllms Reject:

O'JI.

Measured Ar9fe:...

Mode:

Shear PRF:

Couplanl IDNaech s.a*

Auto High SU Freq.:

2.21 MHz Exit Pcint:

o.r ti of Elements:

1 Frequency:

2.25MHz Rectify:

Fulwave

--- Cal Balch:

16G015 Circumferential Oriented s-rc:h Unit Config.:

Single Focus:

NIA VOllage:

450 Pulse Wldlh:

220 Shape:

Contour:

Flat Type:

Ulragell Calibration Signal Sweep Sound Pait!

Rect.

Mfg.:

Sonoteclt Reflector Ampliudellll DiYisian Wedge Style:

sws NIA NIA NIA NIA Ax. Gain (dB):

41.0 Circ. Gain (dB):

NIA Sean:h Unit cable Exam Batch:

160015 1

Sc:reen Div. =

o.75 in. of Sound Path Type:

RG-174 Length: 12" No. Com.: O Type:

unrage1 a Mfg.:

Sonotech Calibration Block Scan Coverage Cal. Bloc;I< No.:

BWD-071 Upsnem~ 0ownstreamO Sc:ancf8: _.!:!..

Ref1tence Block ReferencelSimulor Blocll Thickness:

3.1*

Dia.:

Flat cwo CCW0 Scan dB:~ Serial No.:

SAP 1034l0 CS Gain Signal Sweep sound Plllh dB Refledor AmDlitudellll DMslon Cal. Bit Temp.: _!!! Temp. Tool:

SAP106896 Exam Surface:

OD Type:

1*Ang1eaeam 29.S NSDH 76%

1.4 1.0-Comp. Temp.:.!!:! Temp. Tool:

SAP106896 Surface Condition:

Gtound fklsb 29.S FSDH 2.7 2.0-Recordable lndicationls):

Yes 0 No~

(H Yes, Ref. Aatached Ulrasonic Indication Report.)

Rasulls:

Accepl li2J Rejecl 0 Info Q Comments: See Conments on Page 4.

Percent Of Coverage Obtained > 9()116:

74.7%

Examiner l8val ll-PDI Steinbauer, Troy Examiner Lewi NIA NIA Other Lewi NIA NIA RS-20-012 Attachment 2 ReWewect Previous Data:

Yes Date 9/30/2016 Date Signnlre Date Reviewer Delbusso, James Level Ill Site Review

"""" *-4.~

IA.MesiH ANllReview

  1. ,q,,.:_

Date 9/30IZ016 Dare

/0 Date

/t1-~1 -.i.a14.

____Egge 3 _

~*

Exelon,

Supplemental Report Report No.:

A1R19-UT.023 Page:

4 of 5

Summary No.:

Examiner:

1-803.110.0015

~

Steinbauer, Tr~~

evel: ll*PDI Reviewer:

913012018 Examiner: NIA

~

Level:

NIA Site Review:

ate:

1et-&. ** '-

Other: NIA Level:

NIA ANll Review: A:{t-.m.A,,,j, 41mL. Oate:M4 1M/"

Comments:

1PZR..01-N1 NOTE: Axial scans llmlted to a "w" dimension of 6.0" from nozzle taper for 86" (290*) due to proximity of heater penetration tubes. Scans were not limlted for 16" (70°).

Total Weld Volume:

1305.85 In' (Volume obtained from Report# A1R13-UT.015).

UPST Coverage Missed: 270.2 In' Coverage Achieved: 79.3%

1305.85 In*. 270.2 In** 1035.65 tn* 1035.65 ln'/1305.85 In'= 0.793 0.793 x 100.. 79.3%

DNST Coverage Missed: 711.76 In' Coverage Achieved: 45.5%

1305.85 In'* 711.76 In'.. 594.09 in' 594.09In'/1305.85 In',. 0.455 C>.455 x 100 = 45.5%

cw Coverage Missed: 189.74 In' Coverage Achieved: 87.0%

1305.85 In' -189.74 In' :o 1138.11 In' 1136.11 In'/ 1305.85 In'* 0.870 0.870 x 100

  • 87.0%

ccw Coverage Mlsaed: 189.74 In' Coverage Achieved: 87.0%

1305.85 In' -169.74 tn*

  • 1138.11 In* 1138.11 In'/ 1305.85 In'* 0.870 0.870 x 100
  • 87.0%

TOTAL COVERAGE (79.3 + 45.5 + 87.0 + 87.0) / 4. 74.70/o RS-20-012 Attachment 2 Page 4

s:* Exelon, Supplemental Report Report No.:

A1R19-UT-023 Summary No.: 1-803.110.0015 Examiner: Steinbauer, T~~

Examiner:.Nl..-..A'"-------~~------

Other: -N/~A'---------------------------------------

Level: II.POI Level:

NIA Level:

NIA Comments: 1PZR.01-N1 T & C taken from previous Report t A1R13-UT-015 l*PZlt*OI* HI Sketch or Photo:

RS-20-012 Attachment 2 Page:

5 of 5

Reviewer: Delbusso, James Level Ill 4,~

Date: 9/30/2016 Site Review: 11~i.i~:n ~nie\\\\er 4.. ~.}11'"(.l nr-Date: JO=tdA ANll Review: 4:1+. /11<*&.;, ffeJ#.e?.

Date: Nel.. Nf~

\\

  • T*UUC.A>U$...... <*.. 'Foua.,.UN

,,._,.......... CA.)......,. *

,.._.r*: Ac1s-VF*o-S

    • ,.,,,. *** *'1*0'7

.. uo fo&#*rll: n.o*'

,.,.. o nooca.,*tS:,.~s -

~

..,.. o _&.,..,. : 1')0S.IS"'°'

~

-~

_,~,~

r

~<~;{:~:~:~:::~ r: )(

    • ~

- ~.* x) r~~

Site/Unit:

BRW 1

UT Calibration tmination Procedure:

EXE-ISl-210 Outage No.:

A1R19 Summary No.:

1-803.110.0013 Procedure Rev.:

4 FCN-001 Report No.:

A1R19-UT-024 Workscope:

ISi Work Order No.:

01839513-01 Page:

1 of 5

Code:

ASME XI, 2001 Ed, 2003 Ad Cat./ltem:

B-0/83.110 Location:

TOP OF PZR,R-08 Drawing No.:

1PZR-01

==

Description:==

PRESSURIZER - SAFETY NOZZLE System ID:

RY


~

Component ID:

1PZR-01-N4A Size/Length:

1.5" /48.0" Thickness/Diameter:

3.1" / 6" Limitations:

Nozzle Bore Start Time:

1043 Finish Time:

1135 Instrument Settings Search Unit Cal.

Axial Oriented Search Unit Time Date Serial No.:

SAP 104766 Serial No.:

01BXY7 Checks Calibration Signal Sweep Sound Path Manufacturer:

GEIT Manufacturer:

KB-Aerotech Initial Cal.

0742 9/30/2016 Reflector Amplitude%

Division Model:

USN58LSW Linearity:

2016-L-007 Size:

0.50" Model:

Gamma Inter. Cal.

1043 9/30/2016 1/4" TSDH 80%

1.9 0.675" Delay:

0.1130 j.IS Range:

3.500" Freq.:

2.25 MHz Center Freq.:

NIA Inter. Cal.

NIA 112" TSDH 48%

4.1 1.46" M°tl CalNel:

0.2330 INlµs Pulser Type:

Square Inter. Cal.

NIA 3/4"TSDH 28%

6.2 2.16" Exam Angle:

oo Squint Angle:

NIA Damping:

SOOOhms Reject:

0%

Final Cal.

1347 9/30/2016 Measured Angle:

oo Mode:

Long PRF:

Auto High SU Freq.:

2.25 MHz Couplant Exit Point:

N/A

  1. of Elements:

1 Frequency:

2.25 MHz Rectify:

Full wave

-- Cal. Batch:

16G015 Circumferential Oriented Search Unit Config.:

Single Focus:

N/A Voltage:

450 Pulse Width:

220 Type:

Ultragel II Calibration Signal Sweep Shape:

Round Contour:

FLAT Reflector Amplitude%

Division Sound Path Mfg.:

Sonotech Wedge Style:

sws NIA N/A N/A NIA Ax. Gain (dB):

2.9 Circ. Gain (dB):

NIA Exam Batch:

16G015 Search Unit Cable 1

Screen Div. =

0.35 in. of Sound Path Calibration Block Cal. Block No.:

BWD-071 Thickness:

3.1" Dia.:

Flat Cal. Blk. Temp.: 69° F Temp. Tool:

SAP 106896 Comp. Temp.:

78° F Temp. Tool:

SAP 106896 L-'

~

Results:

Accept ~

Reject D Percent Of Coverage Obtained > 90%:

68.7%

Examiner Level Steinbauer, Troy Examiner Level NI.

NIA Other Level NIA N/A RS-20-012 Attachment 2 Type:

Ultragel II Type:

RG-174 Length: s* No. Conn.: O Mfg.:

Sonotech Scan Coverage Upstream~ Downstream ~ Scan dB:

8.9 Reference Block Reference/Simulator Block cw o CCW O Scan dB: N/A Serial No.:

Exam Surface:

Surface Condition:

Info O Reviewed Previous Data:

Signature OD Type:

Ground Flush po Yes Date I Reviewer 9/30/2016 Oelbusso, James Date I Site Review Hall, Kevin Date I ANll Review Gain Signal Sweep Sound Path SAP 105633 CS dB Reflector Amplitude %

Division CS 5Step 0.0 3.0 80%

8.6 2.99" 0.0 2.0 90%

5.7 2.0" Comments: Scanned 100% of weld volume. See Comments on Page 4.

Dose: 6mr.

Signature Signature Date 9130/2016 Date Date I iJ *01*,,;..JJ '-

Page 6

.~g;:~:::::w

~::: j{.. -* ~:} r1..

UT CalibrationV--

~'lmination

_./

Site/Unit:

BRW 1

Procedure:

EXE-ISl-210 Outage No.:

A1R19 Summary No.:

1-803.110.0013 Procedure Rev.:

4 FCN-001 Report No.:

A1R19-UT -024 Workscope:

ISi Work Order No.:

01839513-01 Page:

2 or 5

Code:

ASME XI, 2001 Ed, 2003 Ad Cat./ltem:

B-OIB3.110 Location:

TOP OF PZR,R-08 Drawing No.:

1PZR-01

==

Description:==

PRESSURIZER - SAFETY NOZZLE System ID:

RY

~~~~~~~~~~~~~~~~~~~~~~~-~~~~~~-~-~~~~~~~-~~~~--~~~~~~-~~~~~~~~~

Component ID:

1PZR-01-N4A Limitations:

Nozzle Bore Instrument Settings Serial No.:

SAP 104766 Manufacturer:

GEIT Model:

USN58LSW Linearity:

2016-L-007 Delay:

10.9091 IJS Range:

5.25" M'tl CalNel:

0.1270 inl11s Pulser Type:

Square Damping:

5000hms Reject:

0%

PRF:

Auto High SU Freq.:

2.25 MHz Frequency:

2.25 MHz Rectify:

Fullwave Voltage:

450 Pulse Width:

220 Ax. Gain (dB):

29.8 Circ. Gain (dB):

NIA 1

Screen Div. = 0.525 in. of Sound Path Calibration Block Cal. Block No.:

BWD-071 Thickness:

3.1" Dia.:

Flat Cal. Blk. Temp.: 69° F Temp. Tool:

SAP 106896 Comp. Temp.:

78° F Temp. Tool:

SAP 106896 Recordable lndication(s):

Yes O No ~

Results:

Accept ~

Reject D Percent Of Coverage Obtained > 90%:

68.7%

Examiner Level II-POI Steinbauer, Troy Examiner Level NI~

NIA Other Level NIA NIA RS-20-012 Attachment 2 Size/Length:

1.5" 148.0" Thickness/Diameter:

3.1" 16" Start Time:

1043 Finish Time:

1135 Search Unit Cal.

Axial Oriented Search Unit Time Date Serial No.:

H25005 Checks Initial Cal.

Calibration Signal Sweep Sound Path Manufacturer:

KB-Aerotech 0753 913012016 Reflector Amplitude%

Division Size:

0.50" x 1.0" Model:

Gamma Inter. Cal.

1056 913012016 114" T SDH 80%

2.0 1.01" Freq.:

2.25 MHz Center Freq.:

NIA Inter. Cal.

NIA 1/2" T SDH 70%

4.0 2.05" 45° Inter. Cal.

NIA 314" T SDH 48%

6.0 3.1" Exam Angle:

Squint Angle:

NIA Final Cal.

1344 913012016 514"T SDH 20%

10.0 NIA Measured Angle:

45° Mode:

Shear Couplant ID Notch 22%

8.7 4.5" Exit Point:

0.65"

  1. of Elements:

1

-- Cal. Batch:

16G015 Circumferential Oriented Search Unit Config.:

Single Focus:

NIA Shape:

Rect.

Flat Type:

Ultragel II Calibration Signal Sweep Sound Path Contour:

Reflector Amplitude%

Division Mfg.:

Sonotech Wedge Style:

sws NIA NIA NIA NIA Search Unit Cable Exam Batch:

16G015 Type:

RG-174 Length : ~

No. Conn.: O Type:

Ultragel II Mfg.:

Sonotech Scan Coverage Upstream~ Downstream~ Scan dB: 35.8 Reference Block ReferencefSimulator Block Serial No.:

SAP 103480 CS Gain Signal Sweep Sound Path cw~

CCW ~ Scan dB: 35.8 dB Reflector Amplitude%

Division Exam Surface:

OD Type:

1" Angle Beam 21.4 FSDH 80%

3.8 2.02" Surface Condition:

Ground Flush 21.4 NSDH 64%

1.9 1.01" (If Yes, Ref. Attached Ultrasonic Indication Report.)

Info O Comments: See Comments on Page 4.

Reviewed Previous Data:

Signature Yes Date I Reviewer 913012016 Delbusso, James Level Ill Date I Site Review Hall, Kevin Date I ANll Review Signature Date 913012016 Date Date

/cJ*O 1 * '7JJl<o Page 7

.* :::::-::=:~::::::::..

~W\\.
  1. -:W.::*:*:**

t::. }{~~:¢ ':* ~J f"~

UT Calibration1f. lmination Site/Unit:

BRW 1

Procedure:

EXE-ISl-210 Outage No.:

A1R19 Summary No.:

1-803.110.0013 Procedure Rev.:

4 FCN-001 Report No.:

A1R19-UT-024 Workscope:

ISi Work Order No.:

01839513-01 Page:

3 of 5

Code:

ASME XI, 2001 Ed, 2003 Ad Cat./ltem:

B-D/83.110 Location:

TOP OF PZR,R-08 Drawing No.:

1PZR-01

==

Description:==

PRESSURIZER - SAFETY NOZZLE System ID:

RY

-=:=--------------~-----------~--------~-------------

Com pone n t ID:

1PZR-01-N4A Size/Length:

1.5" / 48.0" Thickness/Diameter:

3.1" / 6" limitations:

Nozzle Bore Start Time:

1043 Finish Time:

1135 Instrument Settings Search Unit Cal.

Axial Oriented Search Unit Time Date Serial No.:

SAP 104766 Serial No.:

009Y45 Checks Initial Cal.

Calibration Signal Sweep Sound Path Manufacturer:

GEIT Manufacturer:

KB-Aerotech 0749 9/30/2016 Reflector Amplitude%

Division Model:

USN58LSW Linearity:

2016-L-007 Size:

0.50" x 1.0" Model:

Gamma Inter. Cal.

1128 913012016 114" TSDH 80%

2.0 1.5" Delay:

15.700 ps Range:

7.500" Freq.:

2.25 MHz Center Freq.:

N/A Inter. Cal.

NIA 112" T SDH 52%

4.0 3.0" M'U CalNel:

0.1270 inlps Pulser Type:

Square Inter. Cal.

N/A 314" T SDH 35%

6.0 4.5" Exam Angle:

60° Squint Angle:

NIA Damping:

5000hms Reject:

0%

Final Cal.

1343 9/30/2016 5/4" T SDH 19%

10.0 NIA Measured Angle:

60° Mode:

Shear Couplant ID Notch 20%

8.4 6.25" PRF:

Auto High SU Freq.:

2.25 MHz Exit Point:

0.7"

  1. of Elements:

1 Frequency:

2.25 MHz Rectify:

Fullwave N;p:-- Cal. Batch:

16G015 Circumferential Oriented Search Unit Config.:

Single Focus:

Voltage:

450 Pulse Width:

220 Shape:

Rect.

Contour:

Type:

Ultragel II Calibration Signal Sweep Sound Path Flat Reflector Amplitude%

Division Mfg.:

Sonotech Wedge Style:

sws N/A NIA NIA NIA Ax. Gain (dB):

41.0 Circ. Gain (dB):

NIA Search Unit Cable Exam Batch:

16G015 1

Screen Div. =

0.75 in. of Sound Path Type:

RG-174 Length: 12' No. Conn.: O Type:

Ultragel II Mfg.:

Sonotech Calibration Block Scan Coverage Cal. Block No.:

BWD-071 Upstream Ii?) Downstream CJ Scan dB: 47.0 Reference Block Reference/Simulator Block Gain Signal Sweep Thickness:

3.1" Dia.:

Flat cwo CCW O Scan dB: NIA Serial No.:

SAP 103480 CS Sound Path dB Reflector Amplitude%

Division Cal. Blk. Temp.: 69° F Temp. Tool:

SAP 106896 Exam Surface:

OD Type:

1" Angle Beam 29.5 NSDH 76%

1.4 1.0" Comp. Temp.:

78° F Temp. Tool:

SAP 106896 Surface Condition:

Ground Flush 29.5 FSDH 80%

2.7 2.0" Recordable lndication(s):

Yes O No ~

(If Yes, Ref. Attached Ultrasonic Indication Report.)

Results:

Accept Ii?)

Reject O Info O Comments: See Comments on Page 4.

Percent Of Coverage Obtained > 90%:

68.7%

Reviewed Previous Data:

Examiner Level Steinbauer, Troy Examiner Level NIA N/A Other Level N/A Signature NIA Yes Date I Reviewer 9/30/2016 Delbusso, James Date I Site Review Hall, Kevin Date I ANll Review

..o.. :-

Signature Date 9/30/2016 Date Date

/,,). {) 1 *.:l<l1 (.

Page 8

Supplemental Report Summary No.: 1-803.110.0013

-?,--;.--?

Steinbauer, y~vel:

11-PDI Examiner:

Examiner: N/A Level:

N/A Other:

N/A Comments:

1PZR-01-N4A 0° - Scan 100% volume.

45° - Scanned in all four directions.

60° - Scanned upstream.

Total Weld Area:

(3.3 + 2.7) I 2 = 3.0 3.0 x 4.5 = 13.5 in3

  • UPST Coverage Missed: 0.63 in2 Coverage Achieved: 95.3%

Level:

N/A Reviewer:

13.5 in2 - 0.63 in2 = 12.87 in2 12.87 in2 / 13.5 ln2 = 0.953 in2 0.953 x 100 = 95.3%

DNST "overage Missed: 8.35 in2 Jverage Achieved: 38.1%

13.5 in2 - 8.35 in2 = 5.15 in2 5.15 in2 / 13.5 in2 = 0.381 in2 0.381x100 = 38.1%

cw Coverage Missed: 3.96 in2 Coverage Achieved: 70.6%

13.5 in2 - 3.96 ln2 = 9.54 in2 9.54 in2 / 13.5 ln2 = 0.706 ln2 0.706 x 100 = 70.6%

ccw Coverage Missed: 3.96 in3 Coverage Achieved: 70.6%

13.5 in2 - 3.96 in2 = 9.54 in2 9.54 ln2 / 13.5 in2 = 0.706 in2 0.706 x 100 = 70.6%

TOTAL COVERAGE (95.3 + 38.1 + 70.6+70.6)14.. 68.7%

RS-20-012 Attachment 2 Report No.:

A1R19-UT-024 Page:

4 of 5

9/30/2016 I c{e;~/:A:J~

Date: t#*D"l *Mlk Page 9

__,,,,,,,,;,,,}.

  • E: ~\\et on

§.'<<<-;:;;:*:**

Supplemen.__, Report Summary No.: 1-803.110.0013

-~

Examiner: Steinbauer,~

Level: II-POI Reviewer:

Level:

NIA Site Review:

Examiner: NIA Other: NIA Level:

NIA ANll Review:

Comments: 1PZR-01-N4A T & C taken from previous Report# A1R12-UT-081.

Sketch or Photo 1 I I I I

I t

.Jo"l."l.~~

RS-20-012 Attachment 2

\\

IPZR.*01-N'IA

--. 'It

~

( -----

~

I

~.,...,..,.

'* l I

I I

...__ ____ -_____ - --q.s~ -

o/5"'.>

Report No.:

Page:

._/

A1R19-UT-024 5

of 5

Date: 913012016 Date: le.fr& /:aa'<

Date: / D*()1 *JA)ff.

  • r>11ct<1JHS AWC C.o..,"f"t>vA r°'O.U.N J'<!ol'\\ PU.v 1<1<1.5 0.1\\rA.

flf:.P*lt.,.11: :,\\IRl'l*U"T*Oi'I PAnD O<l/~Vo'-

      • l

//

/

~~Y I

I 1"2.R lliAO Page 10

~

  • EXE::lOno UT Calibration,..amination Site/Unit:

BRW 2

Procedure:

EXE-ISl-210 Outage No.:

A2R19 Summary No.:

2-B03.110.0013 Procedure Rev.:

5 Report No.:

A2R19-UT-008 Workscope:

ISi Work Order No.:

01894635-01 Page:

of 2

Code:

ASME XI, 2001 Ed, 2003 Ad Cat./ltem:

B-D/B3.110 Location:

BOTTOM PZR,R-26 Drawing No.:

2PZR-01

==

Description:==

PRESSURIZER - SURGE NOZZLE System ID:

RY

~----------------------------------------------------------------~

Component ID: 2PZR-01-N1 Size/Length:

1.30" I 82.00" Thickness/Diameter: 2.5625" I 26.1 O" Limitations:

Yes - Nozzle I Shell configuration, Heater Penetration Tubes.

Start Time:

1014 Finish Time:

1031 Instrument Settings Search Unit Cal.

Axial Oriented Search Unit Time Date Serial No.:

SAP 104766 Serial No.:

B03340 Checks Calibration Signal Sweep Manufacturer:

GEIT Manufacturer:

Krautkramer Initial Cal.

0812 4/29/2017 Reflector Amplitude%

Division Sound Path Model:

USN 58LSW Linearity:

2017-L-001 Size:

0.50" x 1.0" Model:

Gamma Inter. Cal.

NIA 1/4" T Hole 80%

1.5 1.082" Delay:

11.5506 Range:

7.200" Freq.:

2.25 MHz Center Freq.:

NIA Inter. Cal.

1014 4/29/2017 1/2" T Hole 67%

3.0 2.146" M'tl CalNel:

0.1270 Pulser Type:

Square Inter. Cal.

N/A 3/4" T Hole 44%

4.5 3.238" Exam Angle:

45° Squint Angle:

NIA Final Cal.

1135 4/29/2017 Damping:

5000hms Reject:

0%

ID Notch 20%

6.5 4.650" Measured Angle:

45° Mode:

Shear PRF:

Auto High SU Freq.:

2.25 MHz Couplant 5/4" T Hole 19%

7.5 N/A Exit Point 0.70"

  1. of Elements:

1 Frequency:

2.25 MHz Rectify:

Fullwave

-- Cal. Batch:

NIA Circumferential Oriented Search Unit Voltage:

450 Pulse Width:

220 Ax. Gain (dB):

33.8 Circ. Gain (dB):

NIA 1

Screen Div. = 0.72" in. of Sound Path Cal. Block No.

Thickness Cal. Blk. Temp.

Comp. Temp.

Results:

Calibration Block BWD-071 3.1" Dia.:

Flat 68° Temp. Tool:

SAP 105543 as* Temp. Tool:

SAP 105543 (s)

Accept ~

D Reject O

~

Percent Of Coverage Obtained > 90%:

59.2%

Examiner Level 11-PDI Gbemudu, Giovanni Examiner Level NIA NIA Other Level N/A NIA 012 Attachment Config.:

Single Focus:

NIA Type:

Ultragel II Calibration Signal Sweep Sound Path Shape:

Rect.

Contour:

Flat Reflector Amplitude%

Division Mfg.:

Magnaflux Wedge Style:

sws NIA NIA NIA NIA Exam Batch:

N/A Search Unit Cable NIA NIA NIA NIA Type:

Ultragel II NIA Type:

RG-174 Length: 6' No. Conn.: 0 NIA NIA NIA Mfg.:

Magnaflux Scan Coverage NIA N/A NIA N/A Upstream ~ Downstream~ Scan dB: ~

Reference Block Reference/Simulator Block Gain Signal Sweep Sound Path cw~

CCW ~ Scan dB:

  • 47.8 Serial No.:

SAP 104873 CS dB Reflector Amplitude %

Division Exam Surface:

OD Type:

1" Angle Beam 33.8 FSDH 47%

1.5 1.078" C:::11rf~f"O f"':nnrlitinn*

As Fabricated N/A NIA NIA N/A NIA Ultrasonic Indication Report. l N/A NIA NIA NIA NIA Info O Comments: Percentage Coverage Verified from Document A2R13-UT-025. Dose 48 mr.

Reviewed Previous Data:

Signature Signature Yes Date I Reviewer 4/29/2017 Delbusso, James Date Date I ANll Review da-

/h. f'r '

Signature Signature Date 4/29/2017 Date Date D !>"

  • 0 C(. t.. :H ~

Page 11

~

EXtlOn° UT Calibration,..amination Site/Unit:

BRW 2

Procedure:

EXE-ISl-210 Outage No.:

A2R19 Summary No.:

2-803.110.0013 Procedure Rev.:

5 Report No.:

A2R19-UT-008 Workscope:

ISi Work Order No.:

01894635-01 Page:

2 of 2

Code:

ASME XI, 2001Ed,2003 Ad Cat./ltem:

B-D/83.110 Location:

BOTTOM PZR,R-26 Drawing No.:

2PZR-01

==

Description:==

PRESSURIZER - SURGE NOZZLE System ID:

RY

~-----------------------------------------------------------------

Component ID: 2PZR-01-N1 Size/Length:

1.30" I 82.00" Thickness/Diameter: 2.5625" / 26.10" Limitations:

Yes - Nozzle I Shell configuration, Heater Penetration Tubes.

Start Time:

1036 Finish Time:

1057 Instrument Settings Search Unit Cal.

Axial Oriented Search Unit Time Date Serial No.:

SAP 104766 Serial No.:

016K1T Checks Calibration Signal Sweep Manufacturer:

GEIT Manufacturer:

KB-Aerotech Initial Cal.

0817 4/29/2017 Reflector Amplitude%

Division Sound Path Model:

USN 58LSW Linearity:

2017-L-001 Size:

0.50" x 1.0" Model:

Gamma Inter. Cal.

N/A 1/4" T Hole 80%

1.5 1.460" Delay:

14.9719 Range:

9.400" Freq.:

2.25 MHz Center Freq.:

NIA Inter. Cal.

1035 4/29/2017 1/2" T Hole 60%

3.2 2.887" M'tl CalNel:

0.1270 Pulser Type:

Square Inter. Cal.

N/A 3/4" T Hole 40%

4.6 4.270" Exam Angle:

60° Squint Angle:

N/A Final Cal.

1141 4/29/2017 ID Notch 19%

6.7 6.146" Damping:

500 Ohms Reject:

0%

Measured Angle:

57° Mode:

Shear Couplant 5/4" T Hole 17%

7.8 N/A PRF:

Auto High SU Freq.:

2.25 MHz Exit Point 0.70"

  1. of Elements:

1 Frequency:

2.25 MHz Rectify:

Fullwave

-- Cal. Batch:

N/A Circumferential Oriented Search Unit Config.:

Single Focus:

N/A Voltage:

450 Pulse Width:

220 Type:

Ultragel II Calibration Signal Sweep Sound Path Shape:

Rect.

Contour:

Flat Reflector Amplitude%

Division Mfg.:

Magnaflux Wedge Style:

sws N/A N/A NIA N/A Ax. Gain (dB):

48 Circ. Gain (dB):

N/A Exam Batch:

N/A Search Unit Cable NIA N/A NIA N/A 1

Screen Div. = 0.94" in. of Sound Path Type:

RG-174 Length: 6' No. Conn.: 0 Type:

Ultragel II NIA N/A NIA N/A Mfg.:

Magnaflux Calibration Block Scan Coverage NIA N/A NIA N/A Cal. Block No.

BWD-071 Upstream ~ Downstream~ Scan dB:

62 Reference Block Reference/Simulator Block Thickness 3.1" Dia.:

Flat Gain Signal Sweep Sound Path cw~

CCW ~ Scan dB:

62 Serial No.:

SAP 104873 CS dB Reflector Amplitude% Division Cal. Blk. Temp.

68° Temp. Tool:

SAP 105543

-- Type:

Exam Surface:

OD 1" Angle Beam 48 NSDH 53%

0.7 0.638" Comp. Temp.

86° Temp. Tool:

SAP 105543 Surface Condition:

As Fabricated N/A N/A N/A N/A NIA Recordable lndication(s):

Yes O No~

(If Yes, Ref. Attached Ultrasonic Indication Report.)

N/A N/A N/A N/A N/A Results:

Accept ~

Reject O Info O Comments: Percentage Coverage Verified from Document A2R13-UT-025.

Percent Of Coverage Obtained > 90%:

Examiner Level 11-PDI Gbemudu, Giovanni Examiner N/A Other N/A Level N/A Level N/A RS-20-01 2 Attachment 2 59.2%

Reviewed Previous Data:

Signature Yes Date I Reviewer 4/29/2017 Delbusso, James Date I Site Review Kw.~'-

  • Date I ANll Review Signature

()

Date 4/29/2017 Date Date Page 12

8west1nghouse LIMITATION TO EXAMINATION llCITCH

  • Zllil PllOClllUllll~~--~-=l!X!1M:::.::.=l~l~!!o!'
  • \\~Fefl-=~""'

..... ~---~

DATI llllATID lO:

U1' -*- "

llT

-.MO.

,.._ GblRAL lllJ'ORllATIOll TO DllClllll! Al'PllOllllATI SID, LDCATIOll AllD nPe OI' LMfATIOll.

RS-20-012 Attachment 2

""'li.'-0 *

L..~1-~-01-~1 o-...... "' -T6.sc.~1..'!,

__ D&,.

' \\

' \\

W!!!9!

\\

\\

lll!.1"e.t,.

Pe........,.,'°"'

"1V*s~

\\

\\

\\

\\

\\

\\

\\

Page 13

UT Calibratio.

amination Silalllnit BRW I

2 Procedure:

EXE-&210 Outage No.:

A2R17 Summary No.:

2-803.11CUID11 Procedure Rev.:

4 Report No.:

A2A17.uT.OOS Worklcepe:

ISi Work Onlar No.:

Oltl03171.ot Paga:

1 of 4

Code:

AS11E XI. 2ll01 Ed, 2ID03 M B-Qlll3. 110 10P OF PZR,R4G DnMlng No.:

2PZIM>1

~IO:

RY

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-

Component ID: 2PZR-G1-N48 Sizellenglh:

NIA ThiclcnesslDiam 2Jl&25"/91.S*

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Liftll111io11s:

OM elded............. to nozzle conflguretlon S1artTme:

0958 Finish Time:

1415 lnetrument Sealnga s.n:hUnlt Cal.

nme Axial O....._. s..ch Unit a.ta Serial No.:

SAP 30012941 Seriaf No.:

H30048 Checb Calibndion Signal Swaep lnlialCal.

Sound Pait Mlndaclunw:

GEIT Maldactular:

ICB Aerotech 0720 5'5120t4 RelaclDr Amplitude%

Division Model:

USN*SW UnemUy:

A2R17-l.4M Size:

G.50" x 1.0-Modal:

Gamnm lnlar. Cal.

1000 5'112a14 1/4Hole

'°"'

2.0 0.910*

Delay:

12.7219 Rmlge:

ur lnler. Cal.

1SSO 5'M014 112Hole 80%

4.0 1JM*

Fraq.: 2.25 MHz Cenlar Fnlq.:

NIA lnler. Cal.

NIA 314Hole 40%

6.0 2.92" M'ICtJ4/Vet PullerTp:

Squara EmnAlrfle:

45*

Squint Allgte:

NIA Final Cal 1455 5'512D14 l>NollCh 36Yt I.&

4.1&*

Damping:

SOOOllma Reject 0%

Measured Anfle:...!!:.. Mada:...,

Coupl8nt Sl4Hole 33%

10.0 PAF:

Wo!!lgh SU Freq.:

2.2511H2 EllitPolnt O.J-

'of Elements: __!__ cal. 8all::h:

11C021 Cireumferentlal Orlenlldelt s.rch Unit

~

2.25llHI Rectify. Fal....,.

Orig.:

Single Focus:

NIA Vollaga:

450 Pulse Wldlh:

220 Type:

Ulrllgel II callwallon Signal Sweep

~Palh Shape:

fleet.

Conlour:

F1ld Mfg.:

SonotlK:I\\

RellectDr Amplilude%

DIVlllCln Wedge~:

sws ExamBatch:

11825 NIA NIA NIA NIA Ax. Gain (dB):

27 a.c. Gain (cit):

'ZI Selln:ll Unit cable Type:

Ullnlgel U 11 Screen Div.=.....

in.of SoundPalh Type:

RG-174 lenglh: _!'._ No. Conn.:.!., Mfg.:

Sonoliech Cidlblallon Block Sc8ll Cowqge C8L Block No.

8WIMl71 Upslream ~ Downstream~ Scan dB:~

Releiaaa 8locll Rdnl..rslmui.tor Block Gain Signal Sweep Thicllness a1*

Dia.:

0 cw~

ccw~ Scan dB:

41 SerialNo.:

SAP 'ICllZ219 dB Rallector Amlllluda% Division SoundPath Cal. B1k. Temp.,.!!:... T-.. Toot SAP 30007223 Exam Surface:

OD

-- Type:

11Wl'Jpe"2 27 FSH 30%

2.1 1.ll'll1" Camp. Temp....!!:.. Teq>. Tool:

SAP ai00/223 Surface Condition:

Ground 27 N8H 2S'Jlo 0.7 0.340" Rec:GMle lndlclllonCsk vesn No g)

(II Yes. Ref. Allacbed Ullrasonlc Indication Report.)

Aasulls:

Accepl !L.

Reject 0 lnlo 0 Commenls: See page 3 of 4 for com....,..,

P8R:M1l Of Coverage Oblalned > amr.:

11.5%

Aeuiawed PnMolJS Dal8:

&llmnr lllcbMI, DlclreJ Lavel.~ ~

Signlllure e.mn.

WA Olher NIA NIA UM11 NIA RS-20-012 Attachment 2 Signature Signalura Y*

Dal8 I Reviewer 51512014 Philip Shmdllln Dal& I Sita Revi-

.1;iy 1111er Dale I AMI R8lriaw

~

/')?. p.,.~

Dall lfr.4' OS-* f.2.*~/

Page 14

UT Calibratio.bamination

~ 8RW I

2 Procedure:

EXE-ISl-210 OullgeNo.:

A2R17 Sumrn8ly NO.:

2-&m.11o.ao11 Procadura Rev.:

4 ReportNo.:

A2R17-IJT.oos Wodlsalpe:

ISi Work Oldlw No.;

01I03171.ot Page:

2 ol 4

Code:

ASllE XI, 2G01 Ed, 2003 M cat.111em:

&DD.110 Locallan:

TOP OF PZR.R-26 Drawing No.:

2PZR-01 Dw:alplba: PRESSURIZER* SAFETY NOZZLE Syslern ID:

RY

-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-

Com ponanl ID: 2PZIM1-H48 Slz84.anglh:

NIA ThlcknesslDlmne 2.0&25* / 91.s*

-~~~~~~~~~~~~~~~~~~~~~~~~~~~--

Unllllllo11s:

One 9ldld U811111111tion due to llOZlle conlgurdon s...trme:

0958 Flnietl Tme:

1030 lnslrument Setllnp SearcJi Unit C.L Time Diie Axlal Orie1a.. d SMn:h Unit SedalNo.:

SAP 30912948 SerlalNo.:

018TJR Checb

~

Slgnal Sweep lnillal Cat.

Depli

~

GEIT Manufadurer:

KB t\\erotech cmo SISl20t4 Relledor Amplltude%

DMslon Model:

UINSOSW lineelity:

A2A17......

SiZ9:

1.o" Model:

GmDmll Inter. cal. 0990 51!112Dt4 114tlllle

'°"

1.7 0.11" Delay:

G.98M Range:

4.0*

Fftlq.: 2.2& MHz Center Fniq.:

WA Inter.ell.

WA 1/Jtlllle

'°"

3.8 M'I ca/Vf/A; o.2311 Pulser Type:

Squme

&amAngla:

Squint Angle:

NIA Inter. Cal.

WA 314Hole 80%

SA 2.1r o*

-- Ffnal cat.

1125 5151'2014.......

1CIOt%

7.1 3.12" Damping:

saooe....

ReleCt:

O'Xt Measured Angle:...!!!!.... Mode:

Long PRF:

AlllDHlgh SUFnlq.:

2.2511HE EJdt Point NIA

  • of ElamenlS:

1 Coupl8nt Fniqmnc:y.

2.25MHz Rectify:

F.......

Contig.:

Single focus; NIA cat. Balch:

1XGZI Cin:umfetentlal Orienlatlld Sardi Uftit Vollage:

450 Pulse Wldlh:

220 Shape:

Round Confiour:

Type:

Ultragell calbialion Signal Sweep Deplh Rat Mfg.:

SolllDleell Releclor Arnpliluda..

DMslon Wedg8$¥t:

lnlegral WA NIA NIA NIA Ax. Gain (dB):

15 Cift:. Gain (dB):

15 Seerch Unit C8ble ExamBalch:

11125 10 Screen Div...

4 in.cl Deplh Type:

Ullragel U Type:

RG-174 Lenglh: 6' No. Conn.: 0 Mfg.:

So11aeech c.lbndlDn 8lock Scan Coverage Cal. Block No.

8WD471 Upstleam 0 DownsnamO Scan dB:~

Aefel811C981ock ReferencelSlmul Bloclc Tillclrness 3.1*

Dia.:

0 cw~

CGWij ScandB: ~

SerialNo.:

SAP102279 Gain Signal =

Depth dB Rellaclor -~~..

cal. Blk. Tamp. ~

Tamp. Toof:

SAP 300IJ7223 Exam Surface:

OD Type:

llWType2 15 FSH 40%

1.1 0.72" Comp.Temp. £Tamp. Toal:

SAP 3D001223 SUrface Condlllan:

Ground 15 NSH ZO'lft u

0.32" R1card1lll1 lndlcelon(a):

YesO Ho~

(If Yes, Ref. Attached UllrasaNc lndlcallGn Report)

Resub:

Accept~

Reject 0 Info 0 conun** r umtzec1 due to res1r1c:1ec1 8CC88S w1111 t11e 45 **

Pen:ant Of Cawenlge Oblalned > 90%:

81.5%

Reviewed Pnwious Data:

examner lAMI I-POI Signabll8

....... DlclmJ Q, ~.I Eantnar LIMll a

Slgnalure NIA OltlW Lew.I NIA Slgnalura NIA RS-20-012 Attachment 2 Yes Dale 5l!il2014 Date Dale Reviewer Phllp ShmUlln SiteRevlaw ANnANew

~-,,,,. f:. '

k...z:tr" Dale S--llJ-14(

Dale Data o S* /.).,_01~

Page 15

,;:-' Exelon Supplemental Report Summary No.: 2*803.110.0011 Examiner: Michael, Dickey~ ~J Level: ll*PDI Examiner: NIA Level:

Other: NIA Level:

Comments:

Total coverage required= 4.2" x 2.7M = 11.34" 1.2* x 3.0" x 0.5"

  • 1.8" Total* 13.14M Missing axial (Facing Nozzle and away from nozzle)

NIA NIA 99% (Facing up) + 59.9% (Facing down).. 158.9%12.. 79.5%

Missing clrc (Facing CW and CCW) 97.5% (CW)+ 97.&% (CCW) a 195%12

  • 97.5%

79.5% (Axlal) + 97.5% (Clrc) = 177%12 = 88.&%

T & C Taken from previous data report number A2R15*UT*034.

RS-20-012 Attachment 2 Reviewer:

Site Review:

ANll Review:

Report No.:

A2R17-UT*OOS Page:

3 of 4

.:..:.::.:!:..:::.::~~...!.:.~~a~* Date: S*ll>*ty Jay Miiier Date:

C°'""\\1-t'(

Date:".,3.~ 1 '1 Page 16

)

Exelon.

Summary No.: 2-803.110.0011 Sketch or Photo:

""**~~............... -

Pt-'l&~

~

~~~~?-\\~

~

('V'\\*,~oe:.\\~ ~\\re

~~

~w.. cc_c..c..)

/.'

~\\'\\~l~ ~~\\

~\\ ~ t\\'4l0\\.'I RS-20-012 Attachment 2 Supplemental Report Report No.:

A2R17-0T-G05 Page: ~of 4 1"

Page 17

~Jlon.

UT C81ibrati6.

amination SitaAhdt BAW I

2 PIOC8dl.n:

EX£.ISl.210

<Mage No.:

A2R17

--~~~~~~~~~-

Sunmary No.:

2"803.110.ll012 Procadln Rev.:

4 Repolt No.:

A2R17.uT418

--~~~~~~~~~-

Workscope:

ISi Work Onler No.:

01803171-4!

Page:

1 of 4

Code:

ASllE XI, 2001 Ed, 20DI Ad CaL/llem:

B-Dt'B3.110 L.ocallon:

TOP OF PZR.R48

~----------------.......; ______________ _

Dnlwlng No.:

IPZR-01

==

Description:==

PIESSUFllZER - SAFETY NOZZLE S\\ISllm IO:

RY


~-------------------------------------------------

Compoi ient ID: 2PZIM>>1-N4C SiDILangth:

NIA TNclcnesslDlmne 2JllZI",.,_,.


~----------------------------------------~-

Umlldons:

One 9lded...-...... due to ncmle c:onfigunllion sat rime:

0958 Finish Time:

1415 lnstMnenl Selllngs S.n:h Unit Cal.

Axle! OrlelltlllU Search Unit 1lnle Dele SestalNo.:

SAP 30012IMI SerlalNo.:

H30IM8 Checlla C8llnlion lnlllal cal.

Signal Sw9ep SculdPalh

~

GEIT Mam'8clurw:

ICBAwolach 0720..,.,..

Relllldor Ampllude.,.

DMslorl Modll:

USN80SW Linemlly.

A2R17~

Size:

G.50" x1.r Model:

0....

lnlllr. Cal. 1000 Slll2014 114Hole 2.0 G.97r

~

12.7219 Range:

4.1&"

Center Freq.:

lntar. cal 1SSO Slll2014 112Hole 4.0 1.94" Freq.:

2.25 llHz NfA PulserTp:

Inter. Cal.

NIA 314Hole

"°""

&.D 2.12*

M'ICalNal:

0.111&

Sqase EanA19e:.. Squint Angle:

NfA FinaJCaf.

1455 SN2014 IDNaedl 36'l(,

1.6 4.11" Dmnping:

5000bms R.;ect:

°""

Measurad Angle:.. Mode:

Shar PRF:

2.2511HZ Coupl8nt 514 Hole 33"Ai 10.0 4.lr Autottlgh SUFnlq.:

EJdtPoint o.r

  • of ElamenlS: __!_ Cal. Balch:

13C028 Cin:uadaential Orieldalld Searcll Unit ff8qll91Cy.

2.2511Hz Rec:lly:

FullwllVe Canlig.:

Single Focus:

NIA Vollage:

450 Pulse Wldlh:

220 Ax. Gain (dB):

1:1 CIR:. Gain (dB):

1:1 10 SClaan Div...

4.16 In. of SoundPeth c.maration Block cal Block No.

BWDo071 Thlclcness 3.1" Ola.:

0 caL Blk. Tamp...!:!:... Tamp. Tool:

SAP 3GllD12Z3 Comp.Temp....!!:.. Tamp. Tool:

SAP300Cl7222 l........ """'I Aasulls:

Accapt ~

0 Re;ac:t 0 Permnt Of CcMltage Obtained > tor.:

Ea'*-

Leval IMtDI

  • llidtMJl,Dldl8J Ellaminer Level NfA NfA Oller Leval NIA NIA RS-20-012 Attachment 2

~

Type:

Ultnlgel II Calibndion Slgnlll Sweep Shape:

Aect.

Carmut:

Flat Mfg.:

Sonoleeh RallecD Amplllucle.,.

DMsiarl Wedge-:

sws ExamBalch:

11625 NfA NIA NfA Search Unit Cable Type:

Ullragel II Type:

RG-174 L8nglh: 6' No. Conn.: 0 Sonol9ch Mfg.:

Scan Coverage Upstraam ~ Dowlislrellm~ Scan dB:~

......... Bloc:tc

....._ll:elSll11almla1 Block cw~

CCWl!2) Semi dB:

41 Serial No.:

Exam Surface:

OD Type:

SUrface Condllion:

Ground Ultra.sonic lndlcatian Report)

Info 0 Ravi.-d Previous Data:

Y*

Signalunl Signatln Signatwa Data I Reviewer SISl'l014 PhUlp SMmblln Data I Site Review Gain Signal Sweep SAP102279 dB Reflector Amplluda.,. DMslOll IJWType2 1:1 FSH an.

2.1 27 NSH 25%

0.7 Comments

See pege 3 CJf.. far__....._

os-.1 SculdPaltl NIA Saundl'lll 1JY.lll" G.340" Dale Page 18

UT Calibratio,.Examination Sita/Unit BAW I

2 Procadule:

EXE-181-110 OulageNo.:

A2R17 S1A'1'111181Y No.:

a.ao:L 11G.0012 Procedunl Rev.:

4 RepoltNo.:

A2R17-uT~

Wortcscape:

ISi Work Order No.:

01IOl17Mn Page:

2 of 4

Code:

ASllE XI. 2ID01 Ed. 2003 Ad CaL/ltam:

B-Dt'83.110 Localian:

TOP OF PZll,A4I Drawing No.:

2PZRo01 Descdollon: PRESSURIZER* SAFETY NOm.E Systam ID:

RY

~-------------------------------------------------~

Compcnant ID: 2PZR-01-N4C Slzell.anglh:

NIA TlllclcnasslDla 2.0l25" / 91.s*

~----------------------------

UmillltiCll 16:

OM llldld aamlnatlon due to nozzle configuration Start lime:

0958 FlnlshTme:

1DIO Instrument Selllnp Searcll Unit CaL 0...

Ami Orlenlllllld s.n:ti Unll Time Serial No.:

Siii' 30012941 serial No.:

01BTJR Cbec:b ca&bralicn Signal SW8ep lnltialCal.

Ml/2014 Depth ManufacluNr.

GEIT Manufacturer:

IC8 iA8rotecll 0710 AellecD' Ampllude%

DlvislCln Modll:

USNIOSW Llneadly:

A2A17-L *.cl04 Size:

1.cr' Madel:

Gmuna 1n1er. car. OllO

&ISl2014 114Hofe 80%

1.7 OJill" Dalay:

0.1114 Rqe:

4.o" Fniq.: 2.25 MHz Center Fnlq.:

NIA Inter. car.

NIA 11lHole 80%

3.6 1.44*

M'IC.Wel:

IJ.2311 Nlel'Type:

Sqlme Exam.Angle:

SqWnt Angla:

NIA lnl8r. car.

NfA 314Hole 80%

S.4 2.18'"

o*

-- Anal cat.

1125 Sllil2014.......

100.%

u 3.1Z-Dampklg:

5000llms Reject Measun!d Angle:

NIA Mode:

Long Couplant PRF:

AutoHlgh SUFraq.:

2.25 llHz Elclt Point NIA

  • cl Elernants:

1 Fnlquancy:

2.2511Hz Rectify:

Fullwlwe cat Balch*

13C028 Cln:ulnfm*dlml Or*llldld SWdl Unit Conlg.:

Single Foca.m:

NIA Vcllage:

450 Pulse Wrdlh:

220 Shape:

Round Contour:

Flat Type:

Unr.plD Calibration Signal s.ep Deplt Mfg.:

SClllOlilch R8lleclor Amplilude" Diwision Wedge5¥a:

lnt8gnll NIA NIA NIA NIA Ax. Gain (dB):

15 Circ. Gain (dB):

15 Sean:ll Unit cable Exmn Balch:

118Z5 10 Scnlen Div **

4 In. of DepUI Type*

-..in Type:

AG-174 Lenglh: &' No. Conn.: 0 Mg.:

Sal.all ch Cdbrdon Block Sc.nConrage cal Elock No.

8W1).071 Upstream O 0owns1reamo Scan dB:~

Refwence Block

._................. Bloclc ll1iclcness 1.1*

Dia.:

0 cw~

CCW~ Seal dB: 2!_ SerialNo.:

UP1DZZ79 Gain Signal Sweep Daplh dB Rlllectaf Ampliluda "

Division Cal Blk.. Temp *..!!:_ Temp. Toal:

SAP 30007223 Exam Surface:

OD Type:

llWTp2 15 FSH 1.8 0.72" Comp. Temp...!!:_ Temp. Toal:

SAP 30007223 Surface Condition:

Ground 15 NSH...

o.a G.32" Alcoidlbla lndlallon(a):

veso No~

(H Yes, Raf. Attached IJltrasonlc lrldle:atio1 Report.)

Results:

Accepl !/..

Reject 0 Info 0 Commants:.,. utilized due to restrtc1ad -with the 459.

PeR:erll OI Cowerage Obllllned > 90%:

Reviewed PNvlous Dair.

Y*

Examiner Slgnalan Data Aevlewet Slgnalure Dll9 lllchael, DlcUy SN2014 Phlllp Sh8mblJn

~,,.,PL S--~-1'(

examner Slgnalure Data SlteReview om NIA JeyllDler

'S**\\\\-t Oller Leval NIA Signatunt Date ANll Review Dall NIA Aeia 0

RS-20-012 Attachment 2 Page 19

  1. !!"' Exelon Supplemental Report Summary No.: 2*803.110.0012 Examiner: Michael, Dickey ~

~evel: ~

Examiner: NIA Level:

NIA Other: NIA Level:

NIA Comments:

Total coverage required= 4.2" x 2.7"

  • 11.34" 1.2*. 3.0". 0.5". 1.8" Total* 13.14" Missing axial (Facing Nozzle and away from nozzle) 89% (Facing up)+ 69.9% (Facing down)* 158.9%12
  • 78.5%

Mleslng clrc (Facing CW and CCW) 97.5% (CW)+ 97.6% (CCW)

  • 195%12
  • 97.6%

79.6% (Axial) + 97.6% (Clrc)

  • 177%12
  • 88.6%

T 6 C Taken from previous data report number A2R1S*UT*034.

RS-20-012 Attachment 2 Report No.:

A2R17*UT-006 Page:

3 of 4

Site Review: Jay Miiier


~--='+"=t-...... __._.. __

ANI I Review: Ac1......,, ;n. p,,., ** 11 ""*22J;(iL*

Date: r*>H~

Date: o ->*.,.a. 2.c.>ty Page 20

t:

0 a. ! s c

~

CD a.

a.
s en c

.9

~~

w llo -

~

N Q)

Ol Cll a.

N "E

Q)

E

.J::.

(.)

Cll

~

N

~

0 0

N ch Cl::'.

ATTACHMENT 3 Examination Datasheets for 2SG-01-SGN-01A

-E UT Calibratio mi nation Site/Unit BRW 2

Procedure:

EXE-ISl-62 Outage No.:

A2R19


~

Summary No.:

2-803.140.0019 Procedure Rev.:

2 FCN-01 Report No.:

A2A1 !MJT -020 Workscope:

ISi Work Order No.:

01894635.Q1 Page:

1 of 2

Code:

ASME XI, 2001 Ed, 2003 Ad cat.mem:

B-D/83.140 Location:

IMB LOOP A,R-42 Drawing No.:

2SG-o1

==

Description:==

PRIMARY NOZZLE INNER RADIUS Sys~mlD:

~R=C------------------------------------------------:~~--::-------:~-------::;::-;::;:::=::~=:::::--:-::::::;,;-;-:;;'.;:::-

Component ID: 2SG-01-sGN-01A Size/Length:

NIA Thickness/Diameter: 3.1875* / 29.00" Limitations:

Permanent Support Structure.

Start Time:

1330 FmishTime:

1530 Instrument Settings Search Unit Cal.

Time Date Axial Oriented Search Unit Serial No.:

SAP 105419 Serial No.:

008954 Checks calibration Signal Sweep Manufacturer:

GEIT Manufacturer:

KB-Aerotech Initial Cal.

1300 4/3012017 Reflector Amplitude%

Division Sound Path Model:

USN&OSW Linearity:

2017-L-oo2 Size:

o.so* x 1.0*

Model:

Gamma Inter. cal.

NIA A

80%

5.0 10.&0*

Delay:

9.4681 Range:

15.24.

Freq.:

2.25MHz Center Freq.:

NIA Inter. Cal.

NIA B

52%

5.7 12.00" M'UCalNel:

0.2345 Pulser Type:

Square Inter. Cal.

NIA c

50%

6.5 13.70" Exam Angle:

33*

Squint Angle:

NIA Damping:

5000hms Reject:

0%

Final Cal.

1600 4130/2017 D

35%

7.3 15.30" Measured Angle:

33*

Mode:

Long PRF:

Auto High SU Freq.:

2.25 MHz Coup I ant E

25%

8.0 17.00" Exit Point 0.40"

  1. of Elements:

1 Frequency:

2.2511Hz Rectify:

FuHwave Cal. Batch:

15H010 Circumferential Oriented Search Unit Config.:

Single Focus:

NIA Voltage:

450 Pulse Width:

220 Type:

Ultragel II calibration Signal Sweep Shape:

Rect.

Contour:

Rat Reflector Amplitude%

Division Sound Path Mfg.:

Sonotech Wedge Style:

sws NIA NIA NfA NIA Ax. Gain (dB):

60.3 Circ. Gain (dB):

NIA Exam Batch:

1SH010 10 Sound Path Search Unit Cable NIA NIA NIA NIA Screen Div. =

in. of Type:

Ultragel II Type:

RG-174 Length:..!_ No. Conn.: o NIA NIA NIA NIA Calibration Block Mfg.:

Sonotech NIA NIA NIA NIA Scan Coverage C81. Block No.

CWE-44 Upstream I Downstream~ Scan dB: NIA Reference Block Reference/Simulator Block Thickness NIA Dia.:

Flat Gain Signal Sweep Sound Path cw~

CCW ~ Scan dB: 68.3 Serial No.:

SAP 102279 CS dB Reflector Amplitude% Division Cal. Blk. Temp. as* Temp. TOOi:

SAP 105543

-- Type:

llWType2 NIA Exam Surface:

OD NIA NIA NIA NIA Comp. Temp.

72* Temp. Tool:

SAP 105543 NIA NIA NIA NIA NIA Surface Condition:

Smooth (If Yes, Ref. Attached Ultrasonic Indication Repart.)

NIA NIA NIA NIA NJA Results:

Accept !!ti 0

No !ill Reject 0 Info :::J Comments: -

15.24" with display delay adjusted to 30.934". See previous data for limitations. Dose 19.5 mr Percent Of Coverage Obtained > 90%:

85%

Examiner Level 11-PDI Seith, Joseph P.

Examiner Level NIA NIA Other Level NIA NIA RS-20-012 Attachment 3 Reviewed Previous Data:

Signature Yes Date I Reviewer 4l30/2017 Delbusso,Jarnes Oa~ I Site Review Date m._Pv Signature

~-

Date 511/2017 Date Date

"~* ""'" '"~

Page 1

~ Exelon Limitation Record Site/Unit:

BRW 2

Procedure:

EXE*ISl-52

~----------~--~-----


~----------

um mar y No.:

2*803.140.0019 Procedure Rev.:

2 FCN-01

~--------------------~

Workscope:

ISi Work Order No.:

01894635-01

~----------~--~----~

Description of Limitation:

Permanent Structure Limits Examination for 30" of 205" total Inches. 85% Coverage limitations removal requirements:

Radiation field:

Examiner Level Date Reviewer Serth, Joseph P.

4/30/2017 Level Date Level N/A Signature Date RS-20-012 Attachment 3 Outage No.:

A2R19 Report No.:

A2R19*UT-020 Page:

2 Signature of 2

Date 61112017 Page 2 Date

  • 1'1-

ATTACHMENT 4 Examination Datasheets for 2SG-01-SGC-02

~Exelon UT Calibration/Examination Site/Unit:

BRW 2

Procedure:

EXE-ISl-210 Outage No.:

A2R20

~~~~~~~-------

Summary No.:

2.C01.30.0010 Procedure Rev.:

5 Report No.:

A2ft20.UT -4164 Workscope:

ISi Work Order No.:

04648872-01 Page:

1 of 5

Code:

ASME XI, 2001 Ed, 2003 Ad Cat.ntem:

C-A/C1.30 Location:

IMB LOOP A,R-42 Drawing No.:

2SG-01

==

Description:==

TUBESHEET *STUB BARREL System ID:

RC

~-----------------------------------------------------------------------------------------------------

Component ID: 2SG-01-SGC-02 Size/Length:

428.25" Thickness/Diameter:

3.3125" / 11.3' Limitations:

Exam limited due to Component c:onftguratlon.

Start Time:

0950 AnishTune:

1340 Instrument Settings Sean:hUnlt ca1.

Axial Oriented Sean:h Unit Time Date Serial No.:

SAP 105420 Serial No.:

L01012SP Checks Calibration Signal Sweep Manufaclurer.

GEIT Manufacturer:

KB-Aero tech Initial cal.

0835 10/1612018 Reflector AmplitUde%

Division Sound Path Model:

USN80SW Unearity:

A2R20-L-002 Size:

1.0" Model:

Gamma Inter. cal.

0947 10/1812018 1/4"THole 81%

2.0 1.170" Delay:

0.8256 Range:

8.000" Inter. Cal.

NIA 112" THole 60%

2.9 2.344" Freq.:

2.25MHz Center Freq.:

NIA Inter. Cal.

1232 10/16/2018 3/4" THole 45"k 5.1 3.084" M'llcawe1:

0.2307 Pulser Type:

Square Exam Angle:

O" Squint Angle:

NIA Final Cal.

1452 10/18/2018 Damping:

5000hms Reject:

0%

Measured Angle:

NIA Mode:

Long PRF:

Auto High SU Freq.:

2.25MHz Couplant Exit Point N/A

  1. of Elements:

1 Rectify:

-- Cal. Batch:

18C004 Cln:umferentfal Oriented Search Unit Fniquency:

2.25MHz Fullwave Conflg.:

Single Focus:

N/A Vollage:

Pulse Width:

Type:

Ultragel II Calibration Signal SWeep SoundPalh 450 220 Shape:

Round Contour:

NIA Reflector Amplitude%

Division Mfg.:

Magna flux Wedge Style:

NIA NIA NIA NIA NIA Exam Batch:

18C004 Ax. Gain (dB):

25.0 Circ. Gain (dB):

NIA Search Unit Cable Type:

Ultragel II 10 SaaenDlv."'

6.0 In. of Sound Path Type:

RG-174 Length: _!_ No. Conn.:..!_ Mfg.:

Magnaflux Cellbratlon Bloc:k Sc:an Coverage Cal. Block No.

BWD-062CS Upstream &a Downstream~ Scan dB: ~

Referenc:e Block Referenc:e/Slmulator Bloc:k Gain Signal Sweep Thickness 3.95" Dia.:

Flat cw&a CCWli!J Scan dB: 39.0 Serial No.:

SAP 104874 CS dB Reflector Amplitude% Division Sound Path cat. Blk. Temp. ~

Temp. Tool:

SAP108893 Exam Surface:

OD

-- Type:

2" Angle Beam 12.0 Backwall 82%

3.4 2.000" Comp. Temp.

~Temp. Tool:

SAP108893 Surface Condition:

Ground Flush port.)

Results:

Ac:cept ~

D Reject 0

~

Info O Comments: Scanned+ 14 dB over reference sensitivity. See Page 5 for coverage llmltatlons. Dose: 30.0 mR Percent Of Coverage Obtained > 90%:

88.4%

Reviewed Previous Data:

Examiner l.aY9I 11-PDI Davis, PhlUp B.

Signature

  • ~-~

Examiner Level NIA Signature NIA Other Level NIA Signature NIA RS-20-012 Attachment 4 Yes Date I Reviewer 10/16/2018 Delbusso, James WesDyne Level Ill Date I Site Review Hall, Kevin Exelon Level Ill Date I ANH Review Date 10/1812018 Date 18 Date

/dtf#f Page 1

~~Exelon UT Calibration/Examination Site/Unit BRW I

2 Procedure:

EXE-ISl-210 Outage No.:

A2R20 Summary No.:

2..C01.30.0010 Procedure Rev.:

5 Report No.:

A2R20-UT-064 Workscope:

ISi Work Order No.:

04648672-01 Page:

2 of 5

Code:

ASME XI, 2001 Ed, 2003 Ad Cal/Item:

C-AIC1.30 Location:

IMB LOOP A,R-42 Drawing No.:

2SG-01 Desaiption: TUBESHEET *STUB BARREL System ID:

RC ----------------------------------------------------

Component ID: 2SG-01-SGC-02 Size/Length:

426.25" Thickness/Diameter:

3.3125" / 11.3' Limitations:

Exam limited due to Component configuration.

Start Time:

0950 Finish Tune:

1340 lnstn.anent Settings Search Unit Cal.

Axial Oriented Search Unit Time Date SerlalNo.:

SAP105420 Serial No.:

00008Y Chedcs Calibration Signal Sweep Manufactwar:

GEIT Manufacturer:

Krautknlmer Initial Cal.

0825 10/16'2018 Reflector Amplitude%

Division Sound Path Model:

USN80SW Unearity:

A2R20-l.-002 Size:

0.50" x 1.00" Model:

Gamma Inter. Cal.

0945 10/1612018 1/4"THole 81%

1.7 1.52" Delay:

12.3715 Range:

9.000" Freq.:

2.25MHz Center Freq.:

NIA Inter. Cal.

NIA 112" THole 52%

3.5 3.09" M'llC&Wel:

0.1269 Pulser Type:

Square Squint Angle:

Inter. CBI.

1230 10/16/2018 314" THole 30%

5.1 4.56" Exam Angle:

45° NIA Damping:

5000hms Reject 0%

Final Cal 1450 10/18/2018 ID Notch 20%

6.6 5.80" Measured Angle:

45° Mode:

Shear PRF:

AutoHlgh SU Freq.:

Couplant

&14" THole 18%

7.8 7.00" 2.25MHz Exit Point 0.7S"

  1. of Elements:

1 Frequency:

2.2511Hz Rectify:

Fullwave

-- Cat. Batch:

18C004 Circumferential Oriented Search Unit Config.:

Single Focus:

NIA Voltage:

450 Pulse Width:

220 Shape:

Rect.

Contour:

NIA Type:

Ultragel II Calibration Signal Sweep Sound Path Reflector Amplitude%

Division Mfg.:

Magnaflux Wedge Style:

sws NIA N/A NIA NIA Ax. Gain (dB):

33.0 Circ. Gain (dB):

NIA Search Unit Cable Exam Batch:

18C004 10 Screen Div...

9.0 in. of Sound Path Type:

RG-174 Length: 6' No. CoM.: 0 Type:

Ultragef II Mfg.:

Magnaftux Calibration Block Scan Coverage Cal. Block No.

BWD-082CS Upstream~ Downstteam~ Scan dB:~

Reference Block Reference/Simulator Block Thickness 3.95" Dia.:

Flat cw~

ccw~ Scan dB: 47.0 Serial No.:

SAP 104874 CS Gain Signal Sweep Sound Path dB Reflector Amplitude% Division cal. Blk. Temp. ~

Temp. Tool:

SAP106893

-- Type:

2" Angle Beam Exam Surface:

OD 33.0 FSDH 61%

1.2 1.06" Comp. Temp. !!:! Temp. Tool:

SAP106893 Surface Condition:

Ground Flush Recordable lndlclltlon(s):

veso No 1i!J (If Yes, Ref. Attached Ultrasonic Indication Report.)

Results:

Accept li!I Reject 0 Info O Comments: Scanned + 14 dB over reference sensitivity. See Page 5 for coverage Hmltations.

Pefcent Of Cowlrage Obtained > 90%:

Examiner level H-PDI Davis, Philip B.

Examiner Level NIA NIA Other Lewi NIA NIA RS-20-012 Attachment 4 88.4%

Reviewed Previous Data:

>~

~~-

Signature Signature Yes Dater Reviewer 10/1612018 Delbusso, James WesDyne Level Ill Date I Site Review Hall, Kevin Exelon Level Ill Date I ANll Review

. p,, *.,.,,.__

Signature Signature Date 10/1812018 l8 Date

/tJ*/l*h/d.

Page 2

~Exelon UT Calibration/Examination Sita/Unit 8RW 2

Procedure:

EXE-ISl-210 Outage No.:

A2R20

~------------

Summary No.:

2~.30.0010 Procedure Rev.:

6 Report No.:

A2R20-UT-064 Workscope:

ISi Work Order No.:

04648672-01 Page:

3 of 6

Code:

ASME XI, 2001 Ed, 2003 Ad Cat.ntem:

C-AIC1.30 Location:

IMB LOOP A,R-42 Drawing No.:

2SG-01 Oesaiption: TUBESHEET - STUB BARREL System ID:

RC

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-

Component ID:

2SG-01-S~2 Sizell.ength:

428.25'*

Thickness/Diameter:

3.3126" / 11.3' Limitations:

Exam limited due to component configuration.

StartTme:

0950 Finish Time:

1340 Instrument Settings Search Unit Cal.

Axial Oriented Search Unit Time Date Serial No.:

SAP105421 Serial No.:

ooooaw Checks Calibration Signal Sweep Manufactum:

GEIT Manufacturer:

KB-Aerotech Initial Cal.

0830 10/1612018 Reflector Amplitude%

Division Sound Path Model:

USN80SW Linearity:

A1R18-L-003 Size:

0.60" x 1.0" Model:

Gamma Inter. Cal.

0946 10/18/2018 1/4"THole 81%

1.8 2.13" Delay:

16.0334 Range:

12.000" Freq.:

2.26MHz Center Freq.:

NIA Inter. Cal.

1231 10/18/2018 1/2"THole 46%

3.7 4.42" M'UC.Wel:

0.1269 Pulser Type:

Square Exam Angle:

80-Squint Angle:

NIA Inter. Cal.

NIA 314"THofe 31%

5.5 8.66" Damping:

6000hms Reject:

0%

Final Cal 1451 10/16/2018 ID Notch 8%

8.9 8.27" Measuted Angle:

59" Mode:

Shear PRF:

AutoHlgh SU Freq.:

2.26MHz Exit Point 0.65" f# of Elements:

Couplant 614"THole 1

17%

8.2 9.84" Frequency:

2.26MHz Rectify:

Fullwave Config.:

Single Focus:

-- Cal. Batch:

NIA 18C004 Cln:umferenUal Oriented Search Unit Voltage:

450 Pulse Width:

220 Ax. Gain (dB):

41.0 Circ.. Gain (dB):

NIA 10 SaaenDiv. =

12.0 in. of Sound Path Calibration Block Cal. Block No.

~2CS Thickness 3.9S-Dia.:

Flat cat. Blk. Temp. !!! Temp. Tool:

SAP108893 Comp. Temp. !!:,! Temp. Tool:

SAP108893 Reconlable fndlcation(s):

YesO No~

Results:

Accept~

Reject 0 Peratnt Of Coverage Obtained > 90%:

88.4%

Examiner Level 11-PDI Seng, Tony Examiner level NIA NIA Other Level NIA NIA RS-20-012 Attachment 4 Shape:

Rect.

Contour:

Type:

Ultragel II Calibration Signal Sweep Sound Path NIA Mfg.:

Magnaftux Reftedor Amplitude%

Division Wedge Styfe:

sws NIA NIA NIA NIA Search Unit Cable Exam Batch:

18C004 Type:

RG-174 length: 10' No. Conn.: O Type:

Ultragel II Mfg.:

Magnaflux Scan Coverage Upstream~ Downstream~ Scan dB: ~

Reference Block Reference/Slmulator Block CW!i!J ccw~ Scan dB: ss.o Serial No.:

SAP 104874 CS Gain Signal SWeep Sound Path dB Reflector Amplitude% Division Exam Surface:

OD Type:

2" Angle Beam 41.0 FSDH 81%

1.2 1.44" Surface Condition:

Ground Rush (If Yes. Ref. Attached Ultrasonic Indication Report.)

Info O Comments: Scanned + 14 dB over reference senslUvlty. See Page 6 for coverage limitations.

Reviewed Previous Data:

Yes Date I Reviewer 10/18/2018 Oelbusso, James WesDyne Level Ill Signature Date I Site Review Hall, Kevin Exelon Level Ill Signature Date I ANll Review Signature

/()*/

Date 10/18/2018 Page 3

~ Exelon Summary No.: 2-C01.30.0010 Examiner: Davis, Philip B.,zye??

Examiner:...;N..;.;/"-A:...._ _____________ _

Other: _N;...:./c.:...A:...._ _____________ _

Comments: 2SG-01 -SGC-02 Sketch or Photo:

c.o*

115*

~~

-r *

  • 1 RS-20-012 Attachment 4 Supplemental Report Report No.:

A2R20-UT-064 Page:

4 of 5

Level: 11-PDI Reviewer: Delbusso, James WesDyne Level Ill Date: 10/16/2018 Level:

N/A Site Review: Hall, Kevin Exelon Level Ill Date: ~~ll~l\\t:

Level:

N/A ANll Review: Ad-,n. p,.,*~ /ZL.y}?'-f'Z.._,

Date: /4*/l*,z.yt/

tt 45"

.....,-s-j-~

45

  • c,o*

I

\\

I

\\

I 3.5 1

r J I

I I

I

\\

I I

\\

I Page 4

--~ Exelon Supplemental Report Report No.:

A2R20-UT-064 Summary No.: 2-C01.30.0010 */=-

)~- ~

Examiner: Davis, Philip B. ~~r-~

T Examiner:...:N..::/.:.A=----------------

Other:...:N~/.:.A=----------------

Comments: 2SG-01-SGC-02 Limitations due to configuration.

Level: 11-PDI Level:

NIA level:

N/A Reviewer: Delbusso, James WesDyne Level Ill Site Review: Hall, Kevin Exelon Level Ill ANll Review:

/lei;,,.,._ rn, ~.~ ~~-

3-18" HAND HOLES, 10" INSPECTION COVER & 4" BRANCH CONNECTION LIMIT STUD BARREL SIDE SCAN.

Page:

5 of 5

Date: 10/16/2018 Date: l'C I l~~ { 1P:,

Date: /.J*tJA *...z..>16 3-9", 1-10"1NSPECTION COVERS, 7" BRANCH CONNETION, 7" ID PLATE & 6" PLUG BRANCH CONNECTION LIMIT TUBE SHEET SIDE SCAN.

3-9" INSPECTION COVERS & 1 O" INSPECTION COVER LIMITS CIRC SCANS.

Sketch or Photo:

Weld Length* 427.5" P8oLr r

'fl!t1.tr

Z1>1SP!<T10}-'

C.t1t1£,;

-#I

!? "

~

Bf/~J'l<ll (01/N.

ii 2 W{lfJ P"t

-r

fppµrf JI' 88.4% Coverage 981.17"

+

'f!1Jl/

r"'.SP/{Tld#

,covr~

d.e--1110 er. ~""1

,;,,,up.

ti;:;.

Limitations on stud barrel side - 68.0" (84.1 %)

Limitation for tube sheet side - 57.0" (86.7%)

Limitations for circ scans - 37.0" (91.3%) x 2 8".1A1d~

t!o,._,J,

~/{,

yB,.tr

~>-'P:/t"f'1~#

u-vF~

  1. 17 P.I.."('

BRl/N~I(

t:#,.,,..,.

ti 1'1 Fs.c *

+

¥ llt>"7

.r11s,u111I" t!ovr'

~J..5-"U 11/

I 1e I

I

/

WE.LO P/f,/J

$]$

PLul-

!! l/,A,,,,.,

(ON,J,

-If.!J* 0 5iU.8 BRl

    - -----~ -=:1q ~- "'! ~ I~ I I.. ., -~ 5,, s RS-20-012 Attachment 4 Page 5 ATTACHMENT 5 Examination Datasheets for 1 Sl-39-25 \\.,.,..--* \\. Third Jfit-c.r";:tl Sc~~ P-crl~ct ( frcServ1U=J
    • ~ w~~pyn;c Calibration Data Sheet
    .:. ~\\...,.,lu ~.. tlun..,.,. [I.. 1r1. :'°.***l llJ**l l' 11 l;n c;t.-n 1 oilc.. - Plant I Unit Company Braidwood I 1 Comp I System Procedure No. Rev I Chng. No. Cal. Block No. Cal. Block Temp. Thermometer SIN: Size 4" Sch. I RefN~~ock : I D Each Major CRT Div. = Exelon FW-#251 SI EXE-UT-350 210 22572 72°F SAP 106886 160 I 0.531"
    "T" Ferritic [!) Austenitic 0.1" Cal. Direction:

    Scan Area:

    0Axial D Circ. [!] Both I

    to Weld [!]

    II to Weld [!]

    Data Sheet #

    A 1R16-029 Page

    _I __ of --~--

    Cal. Checks I

    Time Initial Calib.

    I 08:05 Initial Calib. Date I 0411612012 Intermediate I

    NIA Search Unit #1 Intermediate I

    NIA Manufacture:

    KBA Serial No.:

    57462976.8 Final Calib.

    09:10 No. of Elements:

    2 Size:

    2(3.5x10)

    Shape:

    Reel.

    Final Calib. Date 0411612012 Freq.

    4.0 MHz Style:

    MSEB4E Exam Angle:

    0° Mode:

    Long Couplant Measured Angie:-

    0° Code Category:

    R-A Code Item:

    R120 Type:

    Ultragel II

    .LSI vJc.\\d Batch:

    09225 I s.r-3'1-2~

    INDICATIONS EXAM ACCESS I FLAW NON RELEVANT SENS.

    Examination Area I Weld YESI NO YES (>50% Ref.)l NO (dB)

    FW#25 1 Sided I Ix Ix 35 Remarks I Reason for Incomplete Scan(s)

    COMPONENT TEMP: 63°F 0° used for T&C. 0° exam performed to locate counterbore and/or ID transition.

    No counterbore detected. Exam volume extended to meet RI-ISi requirements.

    See attached coverage plot. RT stamp located at 0° TDC.

    Wedge Style:

    Integral Search Unit Cable Type:

    RG-174 Length:

    6' No. of Con.:

    0 Instrument Settings Make I Model:

    GEIT USN 60 SW Serial No.:

    SAP 105203 Probe Delay: 9.1209 Range:

    1.0" M'tl Cal I Vel: 0.2270 Pulser: square--

    Damping:

    500" Reiect:

    0%

    PRF:

    Auto High Freq: 4.iJMHz Filter:

    Fixed Mode: Dual On

    /

    Rectify:

    Fullwave Voltage:

    450 Examiners: Joseph Serth

    ~-

    /?--~

    Level II Date 04/16/2012 Pulse Width:

    130 ns Jason J. Jennings *--. _

    _ -4.G II Date 04/16/2012 Display Delay:

    0

    • ~L-~F' ~ /

    Reference Sensitivity (dB)

    WesDyne Reviewer I Date:

    }...'-

    lv L zrr. " zo/J z.

    Axial:

    32-_0.dB Gire:

    32.0 dB

    ~u er Evaluation Required? 0ves ONo NSDH Sens1t1v1ty:

    NIA EXELON LEVEL Ill REVIEW I DATE JI

    _. {) { )

    ill REVIEW I qATE

    .., 11 "~l!r

    '-I *?\\-l"'L 4--- ~ *--

    >\\c.\\caM~ ~ i o~ 0 'oc- ~;\\10..-. ~uc.l.'"""-\\(o<\\"1"'

    RS-20-012 Attachment 5

    \\.

    \\*I I I

    I I

    I I

    I I

    I I\\

    \\

    \\

    I\\

    \\

    '\\ Search Unit #2 Manufactur\\.

    Serial No.: ---------

    No. ofEleme -ts_: ________ _

    Size:

    Shape Freq.

    Style:

    Exam g e:

    Mode: ----

    Measured Angle:.,__ ______ _

    Wedge Style:

    -~--------

    Search \\Jnit Cable N\\A Type:

    Length:

    No. \\)f Con. :

    Instrument Settings Make I Model:

    Serial No.:

    \\

    Probe Delay:

    Range\\

    M'tl Cal I Vel: ---Pulser: ---

    Damping:

    --- Reject: \\

    PRF:

    Freq: -,---

    Filter:

    Mode: -----

    Rectify:

    Voltage:

    Pulse Width:

    Display Delay:

    Reference Sensit1v1ty (dB)

    Axial:

    Circ:

    FSDH Sensitivity:

    .L.1 \\ -i. \\. \\

    \\-..--

    Page 1

    \\..,..---'*

    \\. -.

    ~ w~~pyna:

    Calibration Data Sheet

    ,,:. \\\\...,.1111-jlu*'..... [t.. *.tn. ::0 11111*11*\\'

    Plant I Unit Braidwood I 1 Company Comp I System Procedure No.

    Rev I Chng. No.

    Cal. Block No.

    Cal. Block Temp.

    Thermometer SIN:

    Size 4"

    Ref. Block:

    Sch.

    Exelon FW#25 /SI EXE-PDl-UT-2 710 22572 72"F SAP 106886 160 I 0.531"

    ~~~~~~~~~~ "T' NIA D

    Ferntic [!] Austenitic Each Major CRT Div. =

    0.17" Cal. Direction:

    Scan Area:

    0Axial D Circ. [!] Both I

    toWeld [!]

    II to Weld [!]

    Data Sheet#

    A1R16-029 Page _.;;...l. __

    of 8

    Cal. Checks Time Initial Calib.

    10:06 Initial Calib. Date 04/16/2012 Intermediate NIA Intermediate N/A Final Calib.

    12:08 Final Calib. Date 04/16/2012 Couplant Code Category:

    R-A

    _____ Code Item:

    R120 Type:

    Ultragel II TSI Wc.IJ Batch:

    09225

    \\ S.r-34-ZS INDICATIONS EXAM ACCESS I FLAW NON RELEVANT SENS.

    Examination Area I Weld YES NO YES (>50% Ref.)

    NO (dB)

    FW#25 1 Sided x x

    40.7 Remarks I Reason for Incomplete Scan(s)

    COMPONENT TEMP:63_°F Increased exam volume due to RI-ISi requirements. See attached coverage plot. 50%

    Code coverage achieved due to one side exam. Indication not seen with the o* or 60°RL.

    --- ~.7

    /

    Examiners: Joseg_t: SeFth- *~:...-

    -,;~

    Level II Date 04/16/2012 Jason } *,ieffnings

    '"" ~~:vel II Date 04/16/2012 WesDyne Reviewer I Date: ~

    £>.. ~

    L v{ JU 'i/ &,// Z:.

    Fu, r Evaluation Required?

    (E]Yes DNo

    ~EXELON LEVEL Ill REVIEW I DA TE 1 ti"

    ~ N&tch Search Unit #1 Manufacture:

    KBA Serial No.:

    OOSHOP No. of Elements:

    1 Size: 0.25" Shape:

    Round Freq. 2.25 MHz Style:

    Comp G Exam Angle:

    45* Mode:

    Shear Measured Ang~ 43°

    ---=,........,""'""'=" ___ _

    Wedge Style:

    MSWQC Search Unit Cable Type:

    RG-174 Length:

    6' No. of Con.:

    0 Instrument Settings Make I Model:

    GEIT USN 60 SW Serial No.:

    SAP 105204 Probe Delay: 4.0300 Range:

    1.7" M'tl Cal I Vel: 0.1234 Pulser: square--

    Damping:

    500"" Reject:

    0%

    PRF:

    Auto High Freq: °"2.2'5MHz Filter:

    Fixed Mode: Dual Off Rectify:

    Fullwave Voltage:

    450 Pulse Width:

    220 ns Display Delay:

    O Reference Sensitivity (dB)

    Axial:

    28.7 dB Circ:

    28.7 dB FSDH Sensitivity:

    NIA

    \\

    \\*

    I I

    I I

    I I

    I I

    I I

    \\

    \\

    I\\

    \\

    Search Unit #2 Manuiactu~ :

    Serial No.: \\ ----------

    No. of :le~e~~,~-1---

    Size:

    ""Shape Freq.

    Style:

    Exam ng e:

    Mode:

    Measured Ang:r=le Wedge Style:

    ~~--------

    Search \\Jnit Cable N\\A Type:

    Length:

    No. ~

    Con.:

    Instrument S\\ttings MaKe I Model:

    \\

    Serial No.: -----,----

    Probe Delay:

    Range~

    M'tl Cal I Vel: --- Pulser:

    Damping:

    ---Reject:~

    PRF:

    Freq:

    Filter:

    Mode:

    Rectify:

    Voltage:

    Pulse Width:

    Display Delay:

    Reference Sensitivity (dB)

    Axial:

    Circ.

    FSDH Sensitivity:

    \\

    A--.\\'\\.: o {J !if 1.t--i.1-1-z....

    IANllREVIEWJ:~

    4 \\ "2,...... \\

    \\"'l..---'

    Rt.~"n.~t. --;~i. 1~{ &-(.;.(' c..J..&.;f,oV\\~ ~u...t~"'L°"'1 ~

    RS-20-012 Attachmeht 5

    ~. 11-11:

    Page 2

    ..,,r--*

    \\

    ')'~ w~~~yn;c Calibration Data Sheet

    .. \\"*-'ICU1<,,to.. 1...,.,. (l,,.. \\.HI, (. ;"t\\jt*U *'f' Plant I Unit Braidwood I 1 Data Sheet#

    A1R16-029 Company Exelon Page

    ~

    of _e Comp I System FW#25 /SI Procedure No.

    EXE-PDl-UT-2 I

    Cal. Checks I

    Time Rev I Chng. No.

    710 Cal. Block No.

    SAP 105091 llmtial Calib.

    I 11 :30 Cal. Block Temp.

    63°F Thermometer SIN:

    SAP 106886

    !Initial Calib. Date I 411612012 Size 4"

    Sch.

    160 I 0.531" "T..

    Ref. Block:

    SAP NIA D

    Ferritic [!] Austenitic I Intermediate I

    N/A Each Major CRT Div. =

    0.2" Intermediate N/A Cal. Direction:

    (!]Axial 0 Circ. O Both Final Calib.

    12:10 Scan Area:

    J__toWeld E:3 Final Calib. Date II to Weld 4/16/2012 Couplant Code Category:

    R-A Code Item:

    R120 Type:

    Ultragel II

    .r:sr Wctd Batch:

    09225 INDICATIONS EXAM

    \\ SJ: - 3 CJ-2..5""

    ACCESS FLAW NON RELEVANT SENS.

    Examination Area I Weld YES NO YES (>50% Ref.)

    NO (dB)

    FW#25 1 Sided x

    x 66 Remarks I Reason for Incomplete Scan(s)

    COMPONENT TEMP:_fil°F 50% Code coverage achieved due to one side exam. 60°RL did not see any indications 1n the area of the flaw. Scanning was limited due to lift off at weld area.

    -- -,,/ /

    Examiners: JoS!;ph Senn :,. --

    Level II Date 4/16/2012 Jason J,:'.Jennings

    -'~~vet II Date 4/16/2012 wosoy"e ""'...:; / Dote a...J 'l_, ~

    £.{"HT 'l(l1/rz..

    Furthe,_ valuation Required? [!Jves ONo EXELON LEVEL Ill REVIEW I DATE In,, fr!""\\

    Search Unit #2 Manufacture:

    RTD Serial No.:

    08-375 No. of Elements:

    2 Size:

    2(7x10)

    Shape Rect.

    Freq.

    2.o MHz Style:

    TRLA-2 Exam Angle:

    60° Mode:

    Long Measured Ang~

    58° Wedge Style:

    Integral Search Unit Cable Type:

    RG-174 Length:

    6' No. of Con.:

    0 Instrument Settings Make I Model:

    GEIT USN 60 SW Serial No.:

    SAP 105204 Probe Delay:

    8.01 Range:

    2.0" M'tl Cal I Vel: 0.2270 Pulser: Square Damping:

    ~Reject:

    0%

    PRF:

    Auto High Freq:

    2.0 MHz Filter:

    Fixed Mode: Dual On Rectify:

    Fullwave Voltage:

    450 Pulse Width:

    250 ns Display Delay:

    o Reference Sensitivity (dB)

    Axial:

    66.0 dB Circ:

    NIA NSDH Sensitivity:

    NIA

    \\

    \\.'''

    \\

    \\

    \\

    \\

    \\

    Search Unit #2 Manufactur Serial No.:

    No. ofEleme Size:

    -shape Freq.

    Style:

    Exam ng e:

    Mode: ----

    Measured Angle:

    r--------~

    Wedge Style: ----------

    Search \\Jnit Cable N\\A Type:

    Length:

    ___ No.~ Con.: __

    Instrument S\\ttings Make I Modal: ____ ~\\ ___ _

    Serial No.:

    ~

    Probe Delay:

    M'tl Cal I Vel:

    Range' Pulser:

    Damping:

    Reject: ~---

    PRF:

    Freq: __,.,---

    Filter:

    Mode:

    \\

    Rectify:

    Voltage:\\

    Pulse Width:

    ~

    Display Delay:

    Reference Sens1t1vity (dBi

    \\

    Axial:

    Circ:

    NSDH Sens1tiv1ty:

    /(, ~:ru- '-\\*~1-l"l-ANH REVIEW I If\\ TE J- \\_,-.... ***

    ...&\\~ \\,.__

    I RS-20-012 Attachment ~<<\\.<ru,t..t.. ~i.. 1*{: 6 ~ "-u_;-1-.-..,,..,J tv"'/"-.J,~*

    ~ t

    • Page 3
    • .......--~**

    \\

    ULTRASONIC EXAl\\llNA TION INDICATION REPORT Data Plg. ff: A IR 16-029 rsr wcJd 1 sr-31-Z~

    SITE:

    Braidwood Unit 1 Weld No.:

    FW#25 Datum 0 Location:

    Top Dead Center Procedure No.

    EXE-POl-UT-2 R~.

    7


    ~

    Exam Surface OD 0 ID 0 Thickness :

    0.65" I Exam Volume :

    Lower 113 0 Full 0==:J WMax -

    Distance from CL to SU at Maximum Response Layout shown for MP -

    Metal Path perpendicular scan.

    L -

    Distance from Datum 0 For parallel scan, L's RBR-Remaining Back Reflection

    & Ws would be reversed.

    SU Loe-Search Unit Location Max WMax Forward Backward Ind. I Amp NIA% of DAC NIA% of DAC L

    L1 L2 RBR No.

    %of Max 0%

    0%

    Amp DAC w

    MP W1 MP W2.

    MP DAC DAC 0 degree 1

    15%

    0.2" 0.65" NIA NIA NIA NIA 2.75" 2.5" 3.5" NIA 2

    15%

    0.7"

    .87

    NIA NIA NIA NIA 2.75" NIA NIA NIA 3

    15%

    0.95" 1.16" NIA NIA NIA NIA 2.75" 2.5" 3.5" NIA v

    Add'I. Comments:

    _..-:::-7 PAGE

    ~

    OF 6 W1 WM W2 l

    \\l/07 ~

    Wuld CL I

    f T T l ~-OATUM'll

    ~2 L-:.,.,..L;__ -~.:n*'=t -, ~

    ---t: _{

    l J 6 { 1 j EXAMINATJON ANGLE SU Loe I 0

    45 S 0 45 RL 0 60 S 0 60 RL 0 Other US, OS cw. ccwl REMARKS US l1stLeg-45° US 145° Root - Intermittent 360° US I Bounce - 45° Indications 1 and 3 are the same indication and are not ID connected.

    EXAMINER:

    .._: / /,,,.

    .--_;;:[

    ,,r LEVEL: __

    II Print: /

    JqsepilrS"erth

    (

    DATE:

    4116112 EXAMIN~~

    ~*"

    LEVEL: __

    II Print:

    Jason J. Jennings REVIEWER :

    ~

    REVIEWER: ~~

    L ev.,(_7J!

    1----------------~Authorized lnspecti-OnAen; :

    l L J. **

    RS-20-012 Attachment 5 DATE:

    4/16/12 DATE:

    ~1 (ze1 /t-c.....

    DATE:

    Lt* Z.1-11:.

    DA TE:

    4 \\ -z.. \\ \\ '....__

    \\

    Page 4

    \\.. r-

    \\ ~--

    r~.W..~~.~y1i~

    INDICATION PLOT SHEET

    ,.. \\,"Jt* _. lu ~ IJhuU * * * ' El-

    • lll L :: v 11\\p*t1
    • f PLANT UNIT 1

    TRANSDUCER 008HOP EXAMINER FREQUENCY

    /

    Joseph Sertl('Level ll'and--Jason J. Jennings, Level H CALIB~ON BLOCK 22572 WELD ID#

    FW # 25 I SI

    C Sr IAJc:.ld.

    l sr-3'l-.16"~1z.o1i...

    2c;-

    2.25 DATE

    \\

    Data Sheet No. A1R16-029 Page _s_

    of

    _8_

    ANGLE 45° SIZE 4"

    4/16/2012 I"

    EL{bc.W t....

    V~t-vE:"

    r*

    ~

    I

    { Cvc /

    "Jii"' '-\\-"LI-\\(

    RS-20-012 Attachment 5 r

    ANll REVIEW I DATE CJ 0

    6)

    I I

    0 r

    .-.)

    I L L__...._._..__.1.

    I 4 \\ "2...\\ \\ \\ "\\...--

    Page 5

    \\..,..-

    \\.

    ,~ w~~µ*yn~

    Calibration Data Sheet

    .. \\.'o**.,,IUuJ},,,1_,_ El**.In*
    :':: 111\\J.*11(

    Plant I Unit Company Braidwood I 1 Comp I System Procedure No.

    Rev I Chng. No.

    Cal. Block No.

    Cal. Block Temp.

    Thermometer SIN:

    Size 4"

    Sch.

    I Ref~~ock: I D Each Major CRT Div.=

    Exelon FW#25 I SI EXE-PDl-UT-3 210 22572 63°F SAP 106886 160 I 0.531" "T"

    Ferritic 0Austenitic 0.1"1 0.14" Cal. Direction:

    Scan Area:

    [!)Axial D Circ. D Both I

    toWeld m II toWeld D Data Sheet#

    A1R16-029 Page

    (.,

    of 8 ---

    Cal. Checks Time Initial Calib.

    13:00 Initial Calib. Date 0411612012 Intermediate NIA Intermediate NIA Final Calib.

    16:00 Final Calib. Date 0411612012 Couplant Code Category:

    R-A Code Item:

    R120 Type:

    Ultragel II Isr wc.i~

    Batch:

    09225 I SJ:-3'1-25 fNDICATIONS EXAM ACCESS I FLAW NON RELEVANT SENS.

    Examination Area I Weld YES NO YES (>50% Ref.)

    NO (dB)

    FW#25 1 Sided x x

    Remarks I Reason for Incomplete Scan(s)

    COMPONENT TEMP:63_°F

    • =Adjusted as needed. Used AATI for thru wall sizing of embedded flaw. 45° showed the highest amplitude tip response. RL=0.41" T=0.65" Lower Tip=0.48". Thru wall dimension of 0.07". Flaw was observed with a 60° Shear.

    ,/ -:;',;-- ----

    Examiners: Joseph Serth: /"'- * * :.y/

    Level II NIA

    /

    z=

    Level NIA Date Date 04/16/2012 N/A 7

    -41 I

    WesDyne Reviewer I Date: ~

    f ?,!!,

    '{lz* /1 z.

    L ~ / trr [!Ive, DNo Fu#er Evaluation Required?

    .EXELON LEVEL Ill REVIEW I DATE

    ,,f-

    . A II ----

    / f---.. t 1\\.~ur Lt--i-1-i-z RS-2~~f2A\\t~~~ml~._ -J.,C.a ~Y W;J1*hJ iiv~~***W\\i""I 'l*'"l,.. 7

    ~ I ot;*

    Nbtch Search Unit #1 Manufacture:

    KBA Serial No.:

    OOMXC7 No. ot Elements:

    Size: 0.25" Shape: Round Freq.

    5.0 MHz Style:

    Comp G Exam Angle:

    45° Mode:

    Shear Measured Ang~ 43° Wedge Style:

    MSWQC Search Unit Cable Type:

    RG-174 Length:

    6' No. of Con.:

    0 Instrument Settings Make I Model:

    GEIT USN 60 SW Serial No.:

    SAP 105204 Probe Delay: 4.3156 Range:

    1.0" M'tl Cal I Vel: 0.127 Pulser:

    Square Damping:

    ~Reject:

    0%

    PRF:

    Auto High Freq: To°MHz Filter:

    Fixed Mode: Dual Off Rectify:

    Fullwave Voltage:

    450 Pulse Width:

    100 ns Display Delay:

    o Reference Sensitivity (dB)

    Axial:

    26.8 dB Circ:

    NIA FSDH Sensitivity:

    NIA

    .NII REVIEW I DATE L

    L-1~

    \\..

    Ind lffi Noli::h Search Unit #2 Manufacture:

    KBA Serial No.:

    OOMM7N No. of Elements:

    1 Size:

    0.25" Shape Round Freq.

    5.0 MHz Style:

    Comp G Exam Angle:

    60° Mode:

    Shear Measured Ang~

    58° Wedge Style:

    MSWQC Search Unit Cable Type:

    RG-174 Length:

    6' No. of Con.:

    0 Instrument Settings Make I Model:

    GEIT USN 60 SW Serial No.:

    SAP 105204 Probe Delay: 4.6022 Range:

    1.4" M'tl Cal I Vel: 0.127 Pulser: sq;:iare-Damping:

    ~Reject:

    0%

    PRF:

    Auto High Freq:

    5.0 MHz Filter:

    Fixed Mode: Dual Off Rectify:

    Fullwave Voltage:

    450 Pulse Width:

    100 ns Display Delay:

    o Reference Sensitivity (dB)

    Axial:

    38.4 dB Circ:

    NIA FSDH Sensitivity:

    NIA A\\ '"2..\\ \\ n---

    Page 6

    .~

    Nuclear

    .LSI vJclJ.

    I S.C-3~~2..q ATTACHMENT 3 ASME Planar Flaw Evaluation Form p

    1 f 2 age 0

    Component Number:

    FW-25 Exam Report #:

    A1 R16-029 Indication Number:

    1. 1 I #3 Flaw Type:

    D Surface 0

    ASME Table Utilized:

    IWB-3514-2 Examination Tvoe: D lnservice 0 D

    Class 1 ASME Section XI Code Year:

    2001 I 2003 Addenda ASME Code Class:

    181 Acceptable:

    Class 2 181 Yes D

    No Rounding off of values shall be performed as follows:

    ER-AA-335-010 Revision 2 Page 13 of 21 Subsurface Preservice Express "a", "I", t", Min Depth and Max Depth per paragraph 4.1.1 J Allowable Flaw% to paragraph 4.1.3 "d", *'2d", "0.4d", "S", "all", "a/t", "Y" per paragraph 4.1.2 "t"

    0.65 181 UT Thickness at location excluding cladding D

    Nominal Wall Thickness "I"

    1.0 (Flaw length)

    Min Depth:

    0.40 x

    = 0.41 Max Depth:

    0.50 x

    =

    0.48" 0

    151 Leg Sound Path x Cos Angle = Depth 0

    2"" Leg 2t(Sound Path x Cos Angle) = Depth 0

    Plotted from cross sectional sketch 181 Thru Wall Sizing 0

    Transducer Resolution - Reference note prior to 4.1.1 "S"

    0.15 0.65 0.50

    =

    0.15

    =

    "S" Minimum Flaw Distance to closest component surface = "S" "2d" 0.10 0.50 0.40

    =

    0.10

    =

    "2d" Max Depth minus Min Depth= "2d"

    " 0.4d" 0.02 0.10 I

    2

    =

    0.05 x

    0.4

    =

    0.02

    =

    "0.4d" (2d I 2) 0.4 = "0.4d" Flaw Type:

    181 "Subsurface" if S~ 0.4d D

    "Surface" if S<0.4d, a=2d plus S "d"

    0.05 0.10 I

    2

    =

    0.05

    =

    "d" "2d" divided by 2 = "d" "a"

    0.05 "a" equals "d" for subsurface or "2d" plus "S" for surface "Y"

    1.0 Shall not exceed 1.00 "S" I "a"= uy" 0.10 I

    0.05

    =

    2.0

    =

    • ~y" "Y" functions to reduce the allowable flaw size as the distance to the surface decreases "all" 0.05 Shall Not Exceed 0.50 0.05 I

    1.0

    = 0.05 "a/t" I 7.7% I Actual Flaw %

    0.05 I

    0.65

    = o.on x 100 I 8.6% I Allowable Flaw %

    Linear Interpolation Performed: D Yes 181 No See Attached Work Sheet:

    D Yes 0

    No Comments:

    Indication #1 & #3 are the same indications. Linear interpolation was not performed. The a/I of 0.05 has an alt of 9.6Y for a thickness of 0.312" and 8.6Y for a thickness of 1.0" The actual alt of 7.7% is less than the conservative value of 8.6%.

    Preparer:

    Jay Miller //

    ._..._... J!l * (] U Date:

    04/21/12 Reviewer:

    ? g * ---=-1' }'.I?_ OtJ~~

    l -w-e. ( -rrr Date:

    4 f zd t. 7...

    ANll:

    'J_

    [,._..{.

    Date:

    4\\ "}..\\ \\,.,__

    I RS-20-012 Attachment 5 Page 7

    ~~~.~.!..~~-~yn;c UL TR.-\\SONIC EX.-\\l\\IIK~

    1.aON SKETCH SHEET

    , v*.
    .:-,lt#*'.~,,:a**~:-0 ;i:.... iJ"i:. ~:.n::;:,.* v:*

    Plant/Unit :

    lso. Drwg:

    Braidwood I 1 Comp I System FW # 25 I SI 1Sl-39 ISI Wdci Weld I Component ID Number:

    FW#25 I SI-5'1-25 1"'0511100 u

    ~

    lou "LIU 1

    10.lll-2 10.111 Crown H~ight:

    Flush 3

    10.fD 4

    10.72M Crown Width:

    0.80" 5

    NR 6

    NR Diam\\':t~r :

    4.0" Up Str*arn ( *) SIOfitl 7

    NR 8

    NR Wdd L\\!ngth:

    14.25" 9

    NR Ellww Comp;m~nt 1*

    \\"

    I ELG OW

    --~r-..._,,. \\/A \\...VE COMMENTS:

    ,/.

    Wela I

    FLOW Data Pkg. #: Al\\

    029 Paae

    ~

    of 8

    • \\.",...,.!d EDg*

    DotNn S lr*.. rn ( +) S,a.,,

    Valve Cvmpon~nt EXAMIN> **< / ~.

    LY. II DATE

    -t/ 16/2012 EXM11NER'.-*** -

    ~*-;.

    L\\. II DATE:

    -t/ 1612lll2 rint fuscph Scrth HE VIEWER f!.h,....,) J. fRk b II/. DATE 4 / zdt Z.

    Authorized Inspection Agency J__ l--..c DATE 4\\ ""l.\\.\\ \\v

    . \\

    REVIEWER:

    Print Jason J. Jennin~s l:QJJ DATE: J../- zl-JZ..

    L\\.

    RS-20-012 Attachment 5 Page 8

    ATTACHMENT 6 Examination Datasheets for 2AF-01-24 (FW-3), 2AF-01-25 (FW-4), 2AF-02-23 (FW-1 ), 2AF-02-24 (FW-2), 2AF-03-23 (FW-1 ), 2AF-03-24 (FW-2), 2AF-04-20 (FW-3), 2AF-04-21 (FW-4), 2CV-21-56 (FW-2), 2CV-21-57 (FW-2), 2CV-21-58 (FW-1 ), and 2FW-09-25

    2AF-Ol-24

    ~Exelon UT Calibration, -..<amination Site/Unit:

    BRW 2

    Procedure:

    ER*AA*335-030 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.: l UT-2015-007 Workscope:

    PSI Work Order No.:

    01782044-02 Page:~ of 6

    Code:

    ASME 2001 Edition/ 2003 Addenda Cat/Item:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-15

    ==

    Description:==

    Elbow to Flange System ID:

    _AF

    ______________________________________________________________________________________ -=------:-----1-------:-".""""'-

    Component 10: Field Weld 3 Size/Length:

    0.5"/14.1" Thickness/Diameter:

    0.337" /4*

    Limitations:

    Single Sided Access Start Time:

    1200 Finish Time:

    1225 Instrument Settings Search Unit Cal.

    Axial Oriented Search Unit Time Date Serial No.:

    0221JM Serial No.:

    SC1493 Checks Initial Cal.

    calibration Signal S~p Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech 0720 811312015 Reflector Amplitude%

    DiviSion Model:

    USN&OSW Linearity:

    2015-L-001 Size:

    0.25" Model:

    Comp-G Inter. Gal.

    1200 811312015 o.5" Notch 80%

    7~

    0.12*

    Delay:

    3.5741 Range:

    1.0*

    Inter. Cal.

    1215 8113/2015 NIA NIA NiA NIA Freq.:

    5.0MHz Center Freq.:

    NIA M'llCaWel:

    Pulser Type:

    Inter. Cal.

    N/A NIA NIA NI!'-

    NIA 0.1270 Square Exam Angle:

    45*

    Squint Angle:

    NIA Final Cal.

    1312 8113/2015 Damping:

    5000hms Reject:

    O'Yo NIA NIA NIA NIA Measured Angle:

    46° Mode:

    Shear Couplant NIA NIA NIA NIA PRF:

    Auto High SU Freq.:

    5.0MHz Exit Point 0.2"

    1. of Elements:

    1 Frequency:

    5.0 MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Circumferential Oriented Search Unit Config.:

    Single Focus:

    NIA Voltage:

    450 Pulse Width:

    100 Type:

    Ultragef II Calibration Signal S~ep Sound Path Shape:

    Round Contour:

    NIA Reflector Amplitude 'Yo DiviSion Mfg.:

    Sonotech Wedge Style:

    MSWOC NIA NIA WA NIA Exam Batch:

    13C028 Ax. Gain (dB):

    21 Circ. Gain (dB):

    NIA Search Unit Cable NIA N/A NIA NIA Type:

    Ultragel II NIA NIA NiA NIA 10 Screen Div. =

    1 in. of Sound Path Type:

    RG-174 Length: 6' No. Conn.: O Ml.

    g..

    Sonotech NIA NIA NIA NIA Calibration Block Scan Coverage Gal. Block No.

    BWD-PDl-51&-o2 Upstream ~ Downstream O Scan dB:

    33 Reference Block Reference/Simulator Block Gain Signal sweep Thickness o.s* -2.0*

    Dia.:

    Flat cw~

    CCW ~ Scan dB:

    39 Serial No.:

    142410 cs dB Reflector Amplitude% Divlsion Sound Path Cal. Blk. Temp. 84* Temp. Tool:

    29021141 Exam Surface:

    OD

    -- Type:

    1

    • Angle Beam 21 SOH 50%

    4.5 0.45*

    Comp. Temp.

    106° Temp. Tool:

    29021141 Surface Condition:

    Ground NIA NIA NIA N/A NIA 0

    ~

    p N/A N/A NIA NIA NIA Results:

    Accept~

    Reject O Info O Comments: Cal Block BWO-PDl-51&-02 demonstrated to be ultrasonically equivalent to Flaw Tech C~I Block 22571.

    Baseline Exam.

    Percent Of Coverage Obtained > 90"4:

    No-90%

    Reviewed Previous Data:

    NIA Weld Doc2A.

    Examiner Level Ill

    ~ J ). ~

    Date Reviewer Signature i

    Date

    ./V/4-l Crothers, Simon, P.

    A 8113/2015

    .;CJ/ /'t-":

    Examiner Level NIA Signature Date Site Review Signature Date NIA t:f:.hl'/S H. P?c-~a.n.I ""' zzr 1"'1#/h'~

    /0-/-/S-Other Level NIA Signature Date ANll Review Signature i

    Date J_ \\r..... e..a NIA

    \\....-~

    ~lir"""A~~~

    ( o\\~\\ ~.<""

    RS-20-01 2 Attachment 6

    ! Page 1

    ~Exelon UT Calibratiorl,....xamination Site/Unit:

    BRW 2

    Procedure:

    ER*AA*335-030 Outage No.:

    I N/A Summary No.:

    NJA Procedure Rev.:

    4 Report No.:

    i UT-2015-007 Workscope:

    PSI Work Order No.:

    01782044.()2 Page:

    ~ 2 of 6

    Code:

    ASME 2001 Edition/ 2003 Addenda CatJltem:

    NJA Location:

    Steam Tunnel Drawing No.:

    FX*15

    ==

    Description:==

    Elbow to Flange System ID:

    _AF----------------------~---------------------~---:~-----------....... """."""----

    Component ID: Field Weld 3 Size/Length:

    0.5" / 14.1" Thickness/Diameter:

    0.331* 14*

    Limitations:

    Single Sided Access Start Time:

    1200 Finish Timq:

    1225 Instrument Settings Search Unit Cal.

    Axial Oriented Search Unit Time Date Serial No.:

    0221JM Serial No.:

    SC1489 Checks Sw~p Initial Cal.

    Calibration Signal Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB*Aerotech 0731 8/13/2015 Reflector Amplitude%

    DiviSiOn I

    Model:

    USN60SW Linearity:

    2015-L-001 Size:

    0.25*

    Model:

    Comp-G Inter. Cal.

    1216 8/13/2015 0.5" Notch 80%

    6.0 0.9" Delay:

    4.9803.

    Range:

    1.5" Freq.:

    5.0 MHz Center Freq.:

    NJA Inter. Cal.

    1221 8/13/2015 NIA N/A NiA NIA M'tlCaWel:

    0.1270 Pulser Type:

    Square Exam Angle:

    Squint Angle:

    Inter. Cal.

    NIA NJA NIA NIA NIA 60° NIA Damping:

    5000hms Reject:

    Final Cal.

    1313 8113/2015 NJA NIA NJ.A NIA 0%

    Measured Angle:

    60° Mode:

    Shear NiA PRF:

    Auto High SU Freq.:

    5.0 MHz Couplant NJA N/A NIA Exit Point 0.25"

    1. of Elements:

    1 Frequency:

    5.0 MHz Rectify:

    Fullwave Config.:

    Single Focus:

    -- Cal. Batch:

    N/A 13C028 Circumferential Oriented Search Unit Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    33 Circ. Gain (dB):

    NIA 10 Screen Div. =

    1.5 in. of Sound Path Calibration Block Cal. Block No.

    BWD-PDl-516-02 Thickness 0.5" -2.0*

    Dia.:

    Flat Cal. Blk. Temp. 84" Temp. Tool:

    29021141 Comp. Temp.

    106° Temp. Tool:

    29021141 Recordable lndication(s):

    Yes~

    No 0 Results:

    Accept "

    Reject O Percent Of Coverage Obtained > 90o/o:

    No-90%

    Swtep Shape:

    Round Contour:

    Type:

    Ultragel II Calibration Signal Sound Path N/A Reflector Amplitude%

    Division Mfg.:

    Sonotech Wedge Style:

    MSW QC NJA NIA NiA NIA Search Unit Cable Exam Batch:

    13C028 NJA NIA NIA NIA RG-174 6' No. Conn.: o Type:

    Ultragel II NJA NIA WA NIA Type:

    Length: -

    Mfg.:

    Sonotech NJA N/A NiA N/A Scan Coverage Upstream ~ Downstream O Scan dB:

    39 --

    cwo CCW O Scan dB: NIA Exam Surface:

    OD Surface Condition:

    Ground (If Yes, Rel. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data:

    NIA Reference Block Reference/Simulator Block Serial No.:

    Type:

    Gain Signal SW&ep Sound Path 142410 cs dB Reflector Amplitude% Division 1

    • Angle Beam 28 SOH 80%

    4'.3 0.64" NIA N/A NIA NIA N/A NIA NIA NIA NJA NIA Comments: Cal Block BWO-PDl-516-02 demonstrate~ to be ultrasonically equivalent to Flaw Tech cl.1 Block 22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level 111 o ~

    Date Reviewer Signature Date

    /[/ 1.4-

    /(////-

    Crothers, Simon, P.

    8113/2015 Examiner Level NIA Signature Date Site Review dnature I

    Date NIA A/:~~ //_,,/1?c,,~QA) hl/J.lr

    -#-/h~-z.-.

    / t!J-/-/r-Other Level N/A Signature Date ANll Review Signature Date NIA LSE °f'."\\.~L-A.~~ ~ d- '-.cl.Qo

    \\-\\~\\,;-'

    RS-20-012 Attachment 6 Page 2

    ~Exelon UT Calibratio"1-.1eamination Site/Unit:

    BRW 2

    Procedure:

    ER-AA-335-030 OUtage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    UT-2015-007 Workscope:

    PSI Work Order No.:

    01782044-02 Page: ; 3 of 6

    Code:

    ASME 2001 Edition / 2003 Addenda CatJltem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-15

    ==

    Description:==

    Elbow to Flange System ID:

    AF

    ~--------------------------------------------------------------------------------------------------

    Component ID: Field Weld 3 Size/Length:

    O.S- / 14.1*

    ThickneSS/Diametef.

    0.337* / 4" Limitations:

    Single Sided Access Start Time:

    1200 Finish Tlm111:

    1225 Instrument Settings Search Unit Cal.

    Axial Oriented Search !Jnit Time Date Serial No.:

    0221JM Serial No.:

    0112WB Checks Calibration Signal Sweep Manufacturer.

    GE Inspection Technologies Manufacturer:

    KB-Aerotech Initial Cal.

    0739 8/13/2015 Reflector Amplitude%

    DiviSion Sound Path Model:

    USN60SW Linearity:

    2015-L-001 Size:

    0.25*

    Model:

    Comp-G Inter. Cal.

    1221 8/1312015 0.5* Notch so*;.

    7.~

    1.s2*

    Delay:

    6.2216 Range:

    2.0*

    Freq.:

    5.0MHz Center Freq.:

    NIA Inter. Cal.

    1225 8113/2015 NIA NIA NIA NIA M'llCaWet:

    0.1270 Pulser Type:

    Square Exam Angle:

    Squint Angle:

    Inter. Cal.

    NIA NIA NIA NiA NIA 70° NIA Final Cal.

    1314 8113/2015 NIA NIA NIA NIA Damping:

    5000hms Reject:

    O"lo Measured Angle:

    71° Mode:

    Shear PRF:

    SU Freq.:

    Couplant NIA NIA NiA NIA Auto High.

    5.0 MHz Exit Point 0.3"

    1. of Elements:

    1 Frequency:

    5.0 MHz Rectify:

    Fullwave Config.:

    Single Focus:

    NIA Cal. Batch:

    13C028 Circumferential Oriented S~arch Unit Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    42 Circ. Gain (dB):

    NIA 10 Screen Div...

    2 in. of Sound Path Calibration Block Cal. Block No.

    BWD-POl-516-02 Thickness o.5" - 2.0*

    Dia.:

    Flat Cal. Blk. Temp. 84" Temp. Tool:

    29021141 Comp. Temp. ~

    Temp. Tool:

    29021141 Recordable lndication(s):

    Yes O No~

    Results:

    Accept l!J Reject D Percent Of Coverage Obtained > 90%:

    No-90%

    Type:

    Ultragel II Calibration Signal Sweep Sound Path Shape:

    Round Contour:

    NIA Mfg.:

    Sonotech Reflector Amplitude%

    Divi$1on Wedge Style:

    MSW QC NIA NIA NIA NIA Search Unit Cable Exam Batch:

    13C028 NiA NIA NIA NIA Type:

    RG-174 Length: 6' No. Conn.: O Type:

    Ultragel II NIA NIA NIA NIA Mfg.:

    Sonotech NIA N/A NIA N/A Scan Coverage Upstream ~ Downstream O Scan dB:

    42 --

    cwo CCW D Scan dB: NIA Exam Surface:

    OD Surface Condition:

    Ground (If Yes, Rel. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data:

    NIA Reference Block Reference/Simulator Block Serial No.:

    Type:

    Gain Signal Sweep Sound Path 142410 cs dB Reflector Amplitude% Division 1" Angle Beam 41 SDH 80"/e 5.0 1.0" NIA NIA NIA NJA NIA N/A NIA NIA NIA NIA Comments: Cal Block BWO-PDl-51&-02 demonstrated to be ultrasonically equivalent to Flaw Tech C81Block22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill.,L_ ~

    Date Reviewer Signature Date Crothers, Simon, P.

    8/1312015

    ~/;r-

    ~/ff:

    Examiner Level N/A Signature Date Site Review r'" y;:. /H.:e.L-;

    Date NIA a,£,,,:'5 #, /U&~~A././.V'..zzz:-

    l&:>-/-/S-Other Level. NIA Signature Date ANll Review Signature I

    Date NIA

    \\.._~ ~~~ J-_ ~II**

    . *\\o \\"'1-\\ '.S-RS-20-012 Attachment 6 Page 3

    ~Exelon..

    Supplemental Report Report No.:

    UT-2015-007

    .. - --Summary. No.; *NIA*.. --

    Page:

    4 of 6

    )

    Sketch or Photo:

    Work Package: 01782044-02 Weld: FW-3 Sketch 1: Coverage Plot Weld Crown Width: 0.5" Counterbore US: None Counterbore OS: None Scanned across weld with 45° probe, coverage credit on far side of weld taken with higher angles.

    0.38" 0

    I 1*

    2" I

    I Flow 0.46" Note: 70° used to obtain remaining coverage, scan limited to area shown.

    Circ Coverage Coverage Cale:

    Axial Coverage = 100%

    Circ Coverage = 1.2" of 1.5" exam box width = 80%

    Total= (100% + 80%)/2 = 90%

    c. 1, *** :s ff* 1'1'1cK.L..i1~n/

    d1'f-/11t,l-

    Y~L&MI t.V..J1I

    / ()-I - Ii'° ANI I ANll REVIEW

    \\ '° \\"l-\\,c 3"

    RS-20-012 Attachment 6 REVIEW DATE J_ ~

    Page 4

    ~Exelon..

    Supplemental Report Report No.:

    UT-2015-007 Page:

    5 of 6

    --Summary. Non-NIA- -

    Sketch or Photo:

    )

    Work Package: 01782044-02 Weld: FW-3 Sketch 2: Indication Plot Profile @ 13" Flow 0.48"

    (!)Root Geometry, seen intermittently 360° 0

    1" 2"

    3" Flange I

    I I

    I a./,,./t>> II* he ~o.N

    ._____.._~...1.._----1..~-1---1~~

    M-*9.f-~;~

    £.f'ei41'1/ t. ".za 1(9-1-/ >

    RS-20-012 Attachment 6 ANI I ANll REVIEW REVIEW DATE J.. \\ti.,o.~o\\"1-\\ ~

    Page 5

    ~Exelon,

    Ultrasonic Indication Report Site/Unit:

    BRW I

    2 Summary No.:

    NIA Workscope:

    PSI Search Unit Angle:

    60 0

    Wo Location:

    Centerline Lo Location:

    Extrados MP Metal Path Wmax RBR Remaining Back Reflection W1 L

    Distance From Datum W2 Comments:

    FieldWeld3 Indication w

    Forward Angle No.

    Of Max NIA OIMax DAC w

    MP W1 MP 60" 1

    80".4 0.15*

    0.9" NIA NIA Examiner Level 111 ~~.~ig-~e Crothers, Simon, P.

    Examiner Level NIA Signature NIA Other Level NIA Signature NIA RS-20-012 Attachment 6 Procedure:

    ER*AA-335-030 Procedure Rev.:

    4 Work Order No.:

    01782044-02

    @ Piping Welds O Ferritic Vessels

    .?. 2"T 0 Other NIA Distance From Wo To S.U. At Maximum Response Distance From Wo At NIA Of Max (Forward)

    Distance From Wo At NIA Of Max (Backward)

    Backward L1 L

    L2 RBR NIA Of Max NIA Max N/A Amp.

    Of Of W2 MP Max Max Outage No.:

    NIA Report No.:

    UT-2015-007 Page:

    6 of 6 -

    Wo w-

    ..---+/-ffi ~

    C~I

    --;*-*--------LDATIJM

    • -irr L

    . Lo

    ~

    6 J, J, - r-1:-b.

    0 WI

    ~Y.&nax WI i

    Remarks NIA NIA NIA 13" NIA NIA Root Geometry from us side.

    I I

    Date Reviewer 1)/,4-Signature

    ,,O/~

    Date 8/13fl015 Date Site Review Q~~re Date M..,t<. <... hl,y I

    PrrJ1.r Date ANll Review

    ~ig~:~a-Date l-c:~

    !'-\\""' L-AP-.~~

    ! \\..0,~, \\S" Page 6

    ~Exelon UT Calibratio"1-JCamination 2AF-Ol-25 Site/Unit:

    BRW 2

    Procedure:

    ER*AA-335-030 Outage No.:

    NIA Summary No.:

    NIA Pr()!=edure Rev.:

    4 Report No.:

    i UT *2015-008 I

    Workscope:

    PSI Work Order No.:

    01782044-02 Page: : 1 of 6

    Code:

    ASME 2001 Edition / 2003 Addenda Cat/Item:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-15

    ==

    Description:==

    Flange to Elbow System ID:

    AF Component ID: Field Weld 4 Size/length:

    0.6" / 14.1" Thickness/Diameter ------

    0.337" /4" Limitations:

    Single Sided Access Start Time:

    1200 Finish rim*:

    1225 Instrument Settings Search Unit Cal.

    Axlal Oriented Search.Unit Time Date Serial No.:

    0221JM Serial No.:

    SC1493 Checks Sweep Initial Cal.

    Calibration Signal Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech 0720 8113/2015 Reflector Amplitude%

    Oivi5ion Model:

    USN SO SW Linearity:

    2015-L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    1200 8113/2015 0.5" Notch 80,..

    7i2 0.72" Delay:

    3.5741 Range:

    1.0d Inter. Cal.

    1215 8113/2015 NIA NIA NiA NIA Freq.:

    5.0 MHz Center Freq.:

    NIA M'tl CalNel:

    Pulser Type:

    Inter. Cel.

    NIA NIA NIA NiA NIA 0.1270 Square Exam Angle:

    45° Squint Angle:

    NIA Final Cal.

    1312 8/13/2015 Damping:

    5000hms Reject:

    0%

    NIA NIA NIA NIA Measured Angle:

    46° Mode:

    Shear Couplant NIA NIA NIA NIA PRF:

    Auto High SU Freq.:

    5.0 MHz Exit Point 0.2*

    1. of Elements:

    1 Frequency:

    5.0MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Circumferential Oriented 54tarch Unit Config.:

    Single Focus:

    NIA Voltage:

    450 Pulse Width:

    100 Type:

    Ultragel II Calibration Signal Sweep Sound Path Shape:

    Round Contour:

    NIA Reflector Amplitude%

    Division Mfg.:

    Sonotech Wedge Style:

    MSW QC Exam Batch:

    NIA NIA NIA NIA 13C028 Ax. Gain (dB):

    21 Circ. Gain (dB):

    NIA Search Unit Cable NIA N/A NIA NIA Type:

    Ultragel II NIA NIA NIA NIA 10 Screen Div.=

    1.

    in. of Sound Path Type:

    RG-174 Length: 6' No. Conn.: O Mf.

    g..

    Sonotech NIA Scan Coverage NIA NIA NIA Calibration Block Cel. Block No.

    BWO.PDl-516-02 Upstream O Downstream~ Scan dB:

    33 Reference Block Reference/Slmulator Block Gain Signal SW&ep Thickness 0.5" -2.0*

    Dia.:

    Flat cw~

    CCW ~ Scan dB:

    39 Serial No.:

    142410CS dB Reflector Amplitude 0k Di Vision Sound Path Cel. Blk. Temp. 14* Temp. Tool:

    29021141 Exam Surface:

    OD

    -- Type:

    1

    • Angle Beam 21 SDH 50%

    4.5 0.45.

    Comp. Temp. ~

    Temp. Tool:

    29021141 Surface Condition:

    Ground NIA NIA NIA N/A NIA N/A NIA NIA N/A NIA

    ~

    'port.)

    Results:

    Accept.,,

    D Reject O Info O Comments: Cal Block BWD-PDl-516-D2 demonstrate4 to be ultrasonically equivalent to Raw Tech ~I Block 22571.

    Baseline Exam.

    Percent Of Coverage Obtained > 90%:

    Examiner Level Ill Crothers, Simon, P.

    Examiner NIA Other NIA Level NIA Level NIA RS-20-012 Attachment 6 No-89%

    Reviewed Previous Data:

    Signature Signature NIA Date I Reviewer 8113/2015 Date I Site Review Date Weld Doc2A.

    /V/H-l....&:r t--;\\.~

    ,..-~

    Signature i

    /V//r' Date Signature Date d

    ~/#,d__ ;

    /Cl-I-/

    Signature

    • Date

    \\...:.\\~\\ \\S-Page 7

    ~* EXelon UT Calibratio"'1-.<amination Site/Unit:

    BRW 2

    Procedure:

    ER-AA-335-030 Outage No.: I NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    1 UT*2015-oo&

    Workscope:

    PSI Work Order No.:

    01782044-02 Page:

    2 of 6

    Code:

    ASME 2001 Edition 12003 Addenda Cat./ltem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-15

    ==

    Description:==

    Flange to Elbow System ID:

    AF


    ~-----------.-:~

    Component ID: Field Weld 4 Thickness/Diamete(:

    0.337* 14*

    Size/Length:

    0.6* / 14.1" Limitations:

    Single Sided Access Start Time:

    1200 Finish Time:

    1225 Instrument Settings Search Unit Cal.

    Date Axial Oriented Search Unit Time Serial No.:

    0221JM Serial No.:

    SC1489 Checks Calibration Signal S~p Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aero tech Initial Cal.

    0731 8113/2015 Reflector Amplitude%

    ~on Sound Path Model:

    USN60SW Linearity:

    2015-L-001 Size:

    0.25u Model:

    Comp-G Inter. Cal.

    1216 811312015 o.5* Notch 80%

    6.l>

    0.9*

    Delay:

    4.9803 Range:

    1.5" Freq.:

    5.0MHz Center Freq.:

    NIA Inter. Cal.

    1221 811312015 NIA NIA NIA NIA M'tlCalNel:

    0.1270 Pulser Type:

    Square Exam Angle:

    Inter. Cal.

    NIA NIA N/A

    ~A NIA 60" Squint Angle:

    NIA Damping:

    Reject:

    Final Cal.

    1313 8113/2015 NIA NIA NiA NIA 5000hms 0%

    Measured Angle:

    60" Mode:

    Shear NiA PRF:

    Auto High SU Freq.:

    Couplant NIA NIA NIA 5.0 MHz Exit Point 0.25"

    1. of Elements:

    1 Frequency:

    5.0 MHz Rectify:

    Fullwave Config.:

    Single Focus:

    NJ;:-- Cal. Batch:

    13C028 Circumferential Oriented -rch Unit Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    33 Circ. Gain (dB):

    NIA 10 Screen Div. =

    1.5 in. of Sound Path Calibration Block Cal. Block No.

    BWD-PDl-516-02 Thickness o.s* -2.0".

    Dia.:

    Flat Cal. Blk. Temp.

    84" Temp. Tool:

    29021141 Comp. Temp. ~

    Temp. Tool:

    29021141 Recordable lndication(s):

    Yes~

    NoQ Results:

    Accept ~

    Reject O Percent Of Coverage Obtained > 90%*

    No-89%

    Type:

    Ultragel II Calibration Signal

    swfes, Sound Path Shape:

    Round Contour:

    NIA Mfg.:

    Sonotech Reflector Amplitude%

    Division Wedge Style:

    MSW QC NIA NIA WA NIA Search Unit Cable Exam Batch:

    13C028 NIA NIA NJ.A NIA RG-174 6'

    No. Conn.: 0 Type:

    Ultragel II NIA NIA NIA NIA Type:

    Length: -

    Mfg.:

    Sonotech NIA NIA

    ~A NIA Scan Coverage Upstream O Downstream ~ Scan dB:

    39 --

    cwo CCW O Scan dB: NIA Exam Surface:

    OD Surface Condition:

    Ground (If Yes. Ref. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data*

    NIA Reference Block Reference/Simulator a.tock Serial No.:

    Type:

    Gain Signal Sweep Sound Path 142410 cs dB Reflector Amplitude% Div,ision 1" Angle Beam 28 SDH 809.4 4.3 0.64*

    N/A NIA NIA NJA NIA NIA NIA NIA NIA NIA Comments: Cal Block BWD-PDi.516-02 demonstrateet to be ultrasonically equivalent to Flaw Tech ~I Block 22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill r;. ~

    Dale Reviewer Signature i

    Date Crothers, Simon, P.

    811312015 Pl~

    /0/4 Examiner Level NIA Signature Date Site Review Signature Date NIA a./,,, 's II. /P'&-~~,,. _ *

    .1...v a:z-

    ~/-#,n,vL...

    /P-1-,-_r-Other Level NIA Signature Date ANll Review Signature I

    Date j_ \\.l'I I

    NIA L4='E'

    """-. /lt."'--A\\~ f'rrJ,,q..,....l

    • Ir,
    \\o\\-i..hc RS-20-01 2 Attachment 6 Page 8

    ~E.xelon UT Calibration;a..:.xamination Site/Unit:

    BRW I

    2 Procedure:

    ER-AA-335-030 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    UT-2015-008 Workscope:

    PSI Work Order No.:

    01782044-02 Page: 2-._ of 6

    Code:

    ASME 2001 Edition/ 2003 Addenda CatJltem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-15

    ==

    Description:==

    Flange to Elbow System ID:

    AF


    ~--~~--

    Component ID: Field Weld 4 Size/Length:

    0.6* 114.1*

    Thickness/Diametec:

    0.33r 14*

    Limitations:

    Single Sided Access Start Time:

    1200 Finish Tim~:

    1225 Instrument Settings Search Unit Cal.

    Axial Oriented Search Unit Time Date Serial No.:

    0221JM Serial No.:

    0112WB Checks Calibration Signal sweep Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech Initial Cal.

    0739 8113/2015 Reflector Amplitude%

    Divi~ Sound Path Model:

    USN60SW Linearity:

    2015-L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    1221 8113/2015 0.5* Notch 80-/o 1;~

    1.s2*

    Delay:

    6.2216 Range:

    2.0*

    Freq.:

    5.0MHz Center Freq.:

    NIA Inter. Cal.

    1225 8113/2015 NIA NIA tUA NIA M'tlC8VVel:

    0.1270 Pulser Type:

    Square Exam Angle:

    Squint Angle:

    NIA Inter. Cal.

    N/A NIA N/A NIA NIA 70° Damping:

    Final Cal.

    1314 8113/2015 NIA NIA NiA NIA 5000hms Reject:

    0%

    Measured Angle:

    71° Mode:

    Shear PRF:

    Couplant NIA NIA NIA NIA Auto High SU Freq.:

    5.0MHz Exit Point 0.3*

    1. of Elements:

    1 Frequency:

    5.0 MHz Rectify:

    Fulfwave Config.:

    Single Focus:

    -- Cal. Batch:

    NIA 13C028 Circumferential Oriented ~rch Unit Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    42 Circ. Gain (dB):

    N/A 10 Screen Div.=

    2 in. of Sound Path Calibration Block Cal. Block No.

    BWD-PDl-516-02 Thickness o.5" -2.0*

    Dia.:

    Flat Cal. Blk. Temp. 84" Temp. Tool:

    29021141 Comp. Temp...!!!:. Temp. Tool:

    29021141 Recordable lndication{s):

    Yes O No~

    Results:

    Accept !£.

    Reject O Percent Of Coverage Obtained > 90%:

    No-89°4 Type:

    Ultragel II Calibration Signal Sweep Sound Path Shape:

    Round Contour:

    NIA Mfg.:

    Sonotech Reflector Amplitude%

    Division Wedge Styte:

    MSW QC NIA NIA NiA NIA Search Unit Cable Exam Batch:

    13C028 NIA NIA NIA NIA RG-174 6' No. Conn.: o Type:

    Ultragel II NIA NIA NiA NIA Type:

    Length: -

    Mfg.:

    Sonotech NIA NIA NIA NIA Scan Coverage Upstream O Downstream 0 Scan dB:

    42 --

    cwo CCW O Scan dB: NIA Exam Surface:

    OD Surface Condition:

    Ground (If Yes, Ref. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data:

    NIA Reference Block Reference/Simulator Block Serial No.:

    Type:

    Gain Signal Sweep Sound Path 142410CS dB Reflector Amplitude% Division 1* Angle Beam 41 SDH 80%

    5.0 1.0*

    NIA NIA NIA

    ~A NIA NIA NIA NIA NIA N/A Comments: Cal Block BWD-PDl-516-02 demonstrated to be ultrasonically equivalent to Flaw Tech dai Block 22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill

    ~f *A ~

    Date Reviewer Signature

    ..o/~

    Date Crothers, Simon, P.

    8113/2015

    ,,d/ Examiner Level NIA Signature Date Site Review Signature Date NIA

    /Pt,_,rc;. #./P?e.R..ea.1)

    L.I/ ZZ7 OL-* -?fL~~ /0-/-/S-Other Level NIA Signature Date ANll Review Signature Date J_ k,..,.,.JQ.

    NIA L-E'e"

    ""'-~ ~

    ,,.-. A-N l.... '--M '~

    RS-20-012 Attachment 6 Page 9

    ~Exelon.

    Supplemental Report

    .... Summar:y.No.: N/A-

    /

    Sketch or Photo:

    Work Package: 01782044-02 Weld: FW-4 Sketch 1: Coverage Plot Weld Crown Width: 0.6" Counterbore US: None Counterbore OS: None Profile@ LO (Extrados) 0 1*

    I I

    Flow 0*3811 0.40" 0.38" 0.38" 0.46" Report No.:

    UT-2015-008 Page:

    4 of 6

    2" Note: 70° used to obtain remaining coverage, scan limited to area shown.

    Circ Coverage Coverage Cale:

    Axial Coverage = 100%

    Circ Coverage = 1.25" of 1.6" exam box width = 78%

    Total= (100% + 78%)/2 = 89%

    )

    ANI I ANll REVIEW I

    \\. c

    ~lo'\\ \\.S-REVIEW DATE cf.- \\.,.._;.-.

    Page 10 RS-20-012 Attachment 6

    ~

    ~ Exelon.

    Supplemental Report

    .Summary ~o..:.. NIA ___....... _. _ _____ ___. _

    Sketch or Photo:

    Work Package: 01782044-02 Weld: FW-4 Sketch 2: Indication Plot Profile @ LO (Extrados)

    Flange Flow

    (!)Root Geometry, seen intermittently 360° 0

    1" 2"

    I I

    I Report No.:

    UT -2015-008 Page:

    S of 6

    3" I

    dFJ'f,m~

    'J!',(eUJI(/ /..V.llZ 10* I-I, RS-20-012 Attachment 6 ANI I ANll REVIEW REVIEW DATE L \\.-... ~ ' 0 h.1\\\\.S""""

    Page 11

    \\

    ,.,,::' Exelon, Ultrasonic Indication Report Site/Unit:

    BRW I

    2 Procedure:

    ER*AA-335-030 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    UT-2015-008 :

    Workscope:

    PSI Work Order No.:

    01782044-02 Page:

    6 of 6 :

    Wo

    )'¥'-

    Search Unit Angle:

    ~~~~~~~~

    Wo Location:

    Centerline 60 0

    @ Piping Welds O Ferritic Vessels

    ~ 2"T

    <:;L Wtl W2 t

    Lo Location:

    Extrados 0 Other NIA i

    MP Metal Path w

    o*

    F ToS.U. AtM R

    I esponse I

    --l------~DATIJM

    =orward) :rr Lo

    scickward)

    L~

    • ~

    h

    ~ b 0 J, J, Comments:

    Field Weld 4 Wl

    !~

    \\V.I

    ~

    Indication O/o w

    Forward Backward L1 L

    l2 RBR Remal1<s Angle No.

    Of Max NIA Of Max NIA Of Max NIA Max NIA Amp.

    Of Of OAC w

    MP W1 MP W2 MP Max Max 60" 1

    700.4 0.7" 0.85" NIA NIA NIA NIA NIA o*

    NIA NIA Root Geometry from OS side.

    I I

    I I

    I Examiner Level Ill,f

    . ~

    Date Reviewer Signature I

    Date Crothers, Simon, P.

    A 8113/2015

    /[//;?-

    /!.)/~

    ~

    Examiner Level NIA Signature Date Site Review Signature i

    Date NIA M..,.<< "S.. Ll.v 2-w A'-

    J/rr/t.T Other Level NIA Signature Date ANll Review J..-

    Signature Date NIA

    \\...Jc-e ~

    ~A-N A-r-l

    ~I.lie

    } ""\\"I.\\,~

    RS-20-012 Attachment 6

    Page 12

    2AF-02-23

    §;." Exelon.

    UT Calibration,..:xamination Site/Unit:

    BRW 2

    Procedure:

    ER-AA-335-030 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.: : UT*2015-005 Workscope:

    PSI Work Order No.:

    01782044-02 Page:

    1 of 4

    Code:

    ASME 2001 Edition/ 2003 Addenda Cat/Item:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-15

    ==

    Description:==

    Elbow to Flange System ID:

    AF


    ~------:---

    Com pone n t ID: Field Weld 1 Size/Length:

    o.s* 114.1*

    Thickness/Diameter-0.337* / 4*

    Limitations:

    Single Sided Access Start Time:

    0953 Finish Timt:

    1015 Instrument Settings Search Unit Cal.

    Axial Oriented Search.Unit Time Date Serial No.:

    0221JM Serial No.:

    SC1493 Checks Initial Cal.

    Calibration Slgnal Sweep Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB*Aerotech 0720 8/13/2015 Reflector Amplitude%

    OiviSion Model:

    USN60SW Linearity:

    2015-L-001 Size:

    o.2s*

    Model:

    Comp-G Inter. Cal.

    0953 8/1312015 0.5" Notch 80%

    1:2 0.12*

    Delay:

    3.5741 Range:

    1.0*

    Inter. Cal.

    1003 8/1312015 NIA NIA NIA NIA Freq.:

    5.0 MHz Center Freq.:

    NIA MilCalNel:

    0.1270 Pulser Type:

    Square Inter. Cal.

    N/A NIA NIA NIA NIA Exam Angle:

    45*

    Squint Angle:

    NIA Final Cal.

    1312 8/13/2015 Damping:

    SOOOhms Reject:

    0%

    Measured Angle:

    Mode:

    NIA NIA NIA NIA 46" Shear PRF:

    Couplant NIA NIA NIA NIA Auto High SU Freq.:

    5.0MHz Exit Point 0.2*

    1. of Elements:

    1 Circumferential Oriented ~arch Unit Frequency:

    5.0MHz Rectify:

    Fullwave


    Cal. Batch:

    13C028 Config.:

    Single Focus:

    NIA Type:

    Ultragel II Calibration Signal Sweep Voltage:

    450 Pulse Width:

    100 Sound Path Shape:

    Round Contour:

    NIA Reflector Amplitude 0/.

    Division Mfg.:

    Sonotech Wedge Style:

    MSW QC NIA NIA NIA N/A Exam Batch:

    13C028 Ax. Gain (dB):

    21 Circ. Gain (dB):

    NIA Search Unit Cable NIA NIA NIA NIA Type:

    Ultragel II NIA NIA NIA NIA 10 Screen Div. =

    1 in. of Sound Path Type:

    RG-174 Length: 6' No. Conn.: ~ Mf.

    g..

    Sonotech Calibration Block Scan Coverage NIA NIA NIA NIA Cal. Block No.

    BWD-PDl*51&-o2 Upstream Ii!] Downstream O Scan dB:

    33 Reference Block Reference/Simulator Block Gain Signal Sweep Sound Path Thickness o.s*. 2.ou Dia.:

    Flat cw Ii!]

    CCW ~ Scan dB:

    39 Serial No.:

    142410 cs dB Reflector Amplitude 0.<. Division Cal. Blk. Temp. 84" Temp. Tool:

    29021141 Exam Surface:

    OD

    -- Type:

    1" Angle Beam 21 SOH 50%

    4.5 0.45*

    Comp. Temp.

    98° Temp. Tool:

    29021141 Surface Condition:

    Ground NIA NIA NIA NIA NIA D

    ~

    port.)

    N/A NIA NIA NIA NIA Results:

    Accept.~*

    Reject D Info D Comments: Cal Block BWD-PDl-516..()2 demonstrated to be ultrasonically equivalent to Flaw Tech c81 Block 22571.

    Baseline Exam.

    Percent Of Coverage Obtained > 90%:

    No-90%

    Reviewed Previous Data:

    NIA Weld Doc 2A.

    Examiner Level Ill

    ~ 2. ~ c:tt:

    Date Reviewer Signature Date Crothers, Simon, P.

    8/13/2015

    /I//)'!-

    /[//~

    ~

    Examiner Level NIA Signature Date Site Review a

    Date NIA

    ~. L...,'<- j/. /II"~~-* l.v rrr

    1. Pld 1

    /P-l*tr Other Level NIA Signature Date ANll Review Signature I

    Date I

    J_ k.'2 0..

    I NIA l-oa'C \\V\\.,A..'-A.'°:!>~~

    ~ o\\~\\~

    RS-20-01 2 Attachment 6 page 13

    ~E)celon UT Calibration, -JCamination Site/Unit:

    BRW 2

    Procedure:

    ER-AA-335--030 Outage No.:

    NIA Summary No.:

    N/A Procedure Rev.:

    4 Report No.:

    • UT-2015-005 Workscope:

    PSI Work Order No.:

    01782044-02 Page:

    2 of 4

    Code:

    ASME 2001 Edition/ 2003 Addenda Cat./ltem:

    NIA Locauon:

    Steam Tunnel Drawing No.:

    FX-15

    ==

    Description:==

    Elbow to Flange System ID:

    A:F ____________________________________________________________________________ """:"'"""'."'---::-----:---:--:-:-:::""'.'-::--

    Component ID: Field Weld 1 Size/Length:

    o.5" 114.1" Thickness/Diametet:

    0.337" / 4" Limitations:

    Single Sided Access Start Time:

    0953 Finish Tim~:

    1015 Instrument Settings Search Unit Cal.

    Axial Oriented Search Unit Time Date Serial No.:

    0221JM Serial No.:

    SC1489 Checks Calibration Sweep Initial Cal.

    Signal Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech 0731 8/1312015 Reflector Amplitude%

    OMSion Model:

    USN60SW Linearity:

    2015-L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    1004 8/13/2015 0.5" Notch 80",{,

    6.0 0.9" Delay:

    4.9803 Range:

    1.5" Freq.:

    5.0MHz Center Freq.:

    NIA Inter. Cal.

    1012 8113/2015 NIA NIA NIA NIA M'llCalNel:

    0.1270 Pulser Type:

    Square Exam Angle:

    Squint Angle:

    Inter. Cal.

    NIA NIA NIA NiA NIA 60" NIA Damping:

    5000hms Reject:

    Final Cal.

    1313 811312015 NIA NIA NiA NIA o*.-

    Measured Angle:

    so*

    Mode:

    Shear PRF:

    Auto High SU Freq.:

    Couplant NIA NIA NIA NIA 5.0 MHz Exit Point 0.25"

    1. of Elements:

    1 Frequency:

    5.0MHz Rectify:

    Fullwave Config.:

    Single

    -- Cal. Batch:

    13C028 Circumferential Oriented SUrch Unit Focus:

    NIA Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    33 Circ. Gain (dB):

    N/A 10 Screen Div. =

    1.5 in. of Sound Path Calibration Block Cal. Block No.

    BWD-POl-516-02 Thickness 0.5" -2.0*

    Dia.:

    Flat Cal. Blk. Temp. ~

    Temp. Tool:

    29021141 Comp. Temp.

    98° Temp. Tool:

    29021141 Recordable lndication(s):

    Yes O No~

    Results:

    Accept ~

    Reject O Percent Of Coverage Obtained > 90%:

    No-90%

    Shape:

    Contour:

    Type:

    Ultragel II Calibration Signal Sweep Sound Path Round NIA Mfg.:

    Sonotech Reflector Amplitude%

    ~

    Wedge Style:

    MSW QC NIA NIA NiA NIA Search Unit Cable Exam Batch:

    13C028 N/.A NIA N/A NIA RG-174 6' No. Conn.: O Type:

    Ultragel II NIA NIA NiA NIA Type:

    Length: -

    Mfg.:

    Sonotech NIA NIA NfA NIA Scan Coverage Upstream ~ Downstream O Scan dB:

    39 --

    cwo CCW O Scan dB: N/A Exam Surface:

    OD Surface Condition:

    Ground (If Yes. Ref. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data:

    NIA Reference Block Reference/Simulator Block Serial No.:

    Type:

    Gain Signal sweep Sound Path 142410CS dB Reflector Amplitude% Div.is ion 1 " Angle Beam 28 SDH 80'Yo 4.3 0.64" N/A N/A NIA NIA NIA N/A N/A NIA N/A NIA Comments: Cal Block BWD-PDl-516-02 demonstrated to be ultrasonically equivalent to Flaw Tech Cal Block 22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill ' £!. - ~

    Date Reviewer

    /f.)/,q-Signature Date

    /() /l't-I Crothers, Simon, P.

    8/13/2015 Examiner Level NIA Signature Date Site Review

    ~7ure i

    Date NIA e.,.1,,.,-.s I/. h~.o. -/

    ~vaz r7..

    . -;/,/ /l?v~10-1-1r Other Level NIA Signature Date ANll Review Signature Date I

    NIA

    '--t::...--e ~~~ J_ \\;-_.e

    • i\\.-*\\'"L\\.u-RS-20-012 Attachment 6 Page 14

    ~Exelon

    \\

    UT Cali bratior11... xam i nation Site/Uni I:

    BRW 2

    Procedure:

    ER*AA-335--030 Outage No.:

    NIA

    ~--------------~

    Summary No.:

    Workscope:

    NIA Procedure Rev.:

    Work Order No.:

    4 Report No.:

    • UT*201~

    Page: j 3 of 4

    PSI 01782044-02 Code:

    ASME 2001 Edition / 2003 Addenda CatJllem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX*15

    ==

    Description:==

    Elbow to Flange SysremlD:

    ~A~F---------------------------------""""".------:--:~-----:::-:-:--""""".:="."'"-"'.""".'--:-":::::-".:"'::"-

    Component ID: Field Weld 1 Size/Length:

    o.5" 114,1*

    Thickness/Oiame1er.

    0.337" /4*

    Limitations:

    Single Sided Access SlartTime:

    0953 Finish Tim~:

    1015 Instrument Settings Search Unit Cal.

    I Time Date Axial Oriented Searc:h Unit Serial No.:

    0221JM Serial No.:

    0112WB Checks Calibration Signal Sweep Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB*Aerotech Initial Cal.

    0739 8113/2015 Reflector Amplitude%

    DiviSion Sound Path Model:

    USN &OSW Linearity:

    2015-L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    1012 811312015 o.5" Notch 80%

    7.6 1.s2*

    Delay:

    6.2216 Range:

    2.0*

    Freq.:

    5.0MHz Center Freq.:

    NIA Inter. Cal.

    1018 8113/2015 NIA NIA

    ~A NIA M'tlCaWel:

    0.1270 Pulser Type:

    Square Exam Angle:

    Squint Angle:

    NIA Inter. Cal.

    N/A NIA NIA NIA NIA 70° Damping:

    Final Cal.

    1314 8113/2015 NIA NIA

    ~

    NIA 5000hms Reject:

    0%

    Measured Angle:

    71° Mode:

    Shear Couplant NIA NIA NiA NIA PRF:

    Auto High SU Freq.:

    5.0 MHz Exit Point 0.3"

    1. of Elements:

    1 Frequency:

    5.0MHz Rec lily:

    Fullwave Config.:

    Single Focus:

    -- Cal. Batch:

    NIA 13C028 Circumferential Oriented ~rch Unit Vollage:

    450 Pulse Width:

    100 Ax. Gain (dB}:

    42 Circ. Gain (dB):

    N/A 10 Screen Div. =

    2*

    in. of Sound Path Calibration Block Cal. Block No.

    BWD-PDl-516-02 Thickness 0.5". 2.0*

    Dia.:

    Flat Gal. Blk. Temp. 94* Temp. Tool:

    29021141 Comp. Temp.

    gs* Temp. Tool:

    29021141 Recordable lndication{s):

    Yes O No~

    Results:

    Accept~

    Reject O Percent Of Coverage Obtained> 90"/o*

    No-90%

    Type:

    Ultragel II Calibration Signal Swfep Sound Path Shape:

    Round Contour:

    NIA Mfg.:

    Sonotech Reflector Amplitude%

    Divi$ioo Wedge Style:

    MSW QC NIA NIA WA NIA Search Unit Cable Exam Batch:

    13C028 NIA NIA NIA NIA RG-174 6'

    No. Conn.: O Type:

    Ultragel II NIA NIA NIA NIA Type:

    Length: -

    Mfg.:

    Sonotech NiA NIA NIA NIA Scan Coverage Upstream ~ Downstream O Scan dB:

    42 cwo CCWO Scan dB: N/A Exam Surface:

    OD Surface Condition:

    Ground (If Yes, Ref. Attached Ultrasonic Indication Report.}

    Info O Reviewed Previous Data:

    NIA Reference Block Reference/Simulator Block Serial No.:

    Type:

    Gain Signal SWeep Sound Path 142410CS dB Reflector Amplitude o/o Division 1

    • Angle Beam 41 SDH 80%

    5.0 1.0*

    NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA Comments: Cal Block BWD-PDl*S16-02 demonstra~ to be ultrasonically equivalent to Flaw Tech Cal Block 22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill 'Y-

    . ~

    Date Reviewer Signature JOl/f-f Date Crothers, Simon, P.

    8113/2015 A/).+-

    ~-

    Examiner Level NIA Signature Date Site Review Sig2 L

    Date NIA t!.i11'-'S j/. /Jle.~q,V I.I/.zzz

    .,,-?__

    • ~_/M 10-/-/r

    ~-

    Other Level NIA Signature Date ANll Review Signature I

    Date NIA L~ t-\\~~~

    J.. ~ rt.*

    !\\O \\-z...\\ \\~

    RS-20-012 Attachment 6 I

    Page 15

    ~Exelon.

    Supplemental Report Report No.:

    UT-2015-005 Page:

    4 of 4

    _ Summary No.:. NIA

    ./

    Sketch or Photo:

    Work Package: 01782044-02 Weld: FW-1 Sketch 1: Coverage Plot Weld Crown Width: 0.5" Counterbore US: None Counterbore OS: None Scanned across weld with 45° probe, coverage credit on far side of weld taken with higher angles.

    0.37" 0

    1" 2*

    I I

    Flow Flange Note: 70° used to obtain remaining coverage, scan limited to area shown.

    Circ Coverage Coverage Cale:

    Axial Coverage = 100%

    • Circ Coverage = 1.2" of 1.5" exam box width = 80%

    Total= (100% + 80%)/2 = 90%

    c!,l.T'.'s H*.1'1'-k~u.'V

    ~

    rl /1?~t-,___

    ~£1,.C-v L.li:2Jl

    /Cl-I* I ::r RS-20-012 Attachment 6 ANI I ANll REVIEW

    \\ \\

    \\

    \\0 "l. \\l RFl/IEW DATE t:i:-= \\,\\..

    • t...*

    3" Page 16

    2AF-02-24

    ~E}reton UT Calibratioil,._.<amination Site/Unit:

    BRW 2

    Procedure:

    ER*AA*335-030 Outage No.:

    NIA Summary No.:

    N/A Procedure Rev.:

    4 Report No.:

    I UT-2015-006 Workscope:

    PSI Work Order No.:

    01782044-02 Page: i 1 of 6

    Code:

    ASME 2001 Edition / 2003 Addenda Cat./ltem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-15

    ==

    Description:==

    Flange to Elbow System ID:

    AF

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-;-~~~~~~

    Component ID: Field Weld 2 Size/Length:

    0.5* / 14.1*

    Thickness/Diameter; 0.33r / 4*

    Limitations:

    Single Sided Access Start Time:

    0953 FiniSh Time; 1015 Instrument Settings Search Unit Cal.

    Axial Oriented Search l!Jnit Time Date Serial No.:

    0221JM Serial No.:

    SC1493 Checks Initial Cal.

    Calibration Signal sweep Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech 0720 8/1312015 Reflector Ampfitude"lo Division Model:

    USN60SW Linearity:

    2015-L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    0953 8/1312015 0.5" Notch 80%

    7.~

    0.12*

    Delay:

    3.5741 Range:

    1.0" Inter. Cal.

    1003 811312015 NIA NIA NIA NIA Freq.:

    5.0MHz Center Freq.:

    NIA M'tlCaWel:

    0.1270 Pulser Type:

    Square Inter. Cal.

    N/A NIA NIA NIA NIA Exam Angle:

    45° Squint Angle:

    N/A Final Cal.

    1312 8/1312015 Damping:

    5000hms Reject:

    0%

    Measured Angle:

    NIA NIA NIA NIA 46° Mode:

    Shear Couplant NIA NIA Nl!t NIA PRF:

    Auto High SU Freq.:

    5.0 MHz Exit Point 0.2*

    1. of Elements:

    1 Frequency:

    5.0MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Circumferential Oriented Search Unit Config.:

    Single Focus:

    NIA Type:

    Ultragel II Calibration Signal Sw~ep Voltage:

    450 Pulse Width:

    100 Sound Path Shape:

    Round Contour:

    NIA Reflector Amplitude%

    Division Mfg.:

    Sonotech Wedge Style:

    MSWQC Exam Batch:

    13C028 NIA NIA NIA NIA Ax. Gain (dB):

    21 Circ. Gain (dB):

    NIA Search Unit Cable NIA NIA NIA NIA Type:

    Type:

    Ultragel II NIA NIA NIA NIA 10 Screen Div. =

    1 in. of Sound Path RG-174 Length: 6' No. Conn.: o Mf.

    g..

    Sonotech NIA Calibration Block Scan Coverage NIA NIA NIA cal. Block No.

    BWD*PDl-516-02 Upstream O Downstream~ Scan dB:

    33 Reference Block Reference/Simulator B(ock Gain Signal Sweep Thickness 0.5* -2.0*

    Dia.:

    Flat cw~

    CCW ~ Scan dB:

    39 Serial No.:

    142410 cs dB Reflector Amp~tude 0h.

    Division Sound Path Cal. Blk. Temp. ~

    Temp. Tool:

    29021141 Exam Surface:

    OD

    -- Type:

    1

    • Angle Beam 21 SDH 50%

    4~5 o.4s*

    Comp. Temp.

    98° Temp. Tool:

    29021141 Surface Condition:

    Ground NIA NIA NIA Nl A NIA WA N/A NIA NIA NIA

    ~

    p Results:

    Accept ~

    D Reject O Info O Comments: Cal Block BWO-PDl-516-02 demonstratedlto be ultrasonically equivalent to Flaw Tech Ca! Block 22571.

    Baseline Exam.

    WeldDoc2A.

    Percent Of Coverage Obtained > 90"/0:

    No-90%

    Reviewed Previous Data:

    NIA Examiner Level Ill J )* ~

    Date Reviewer Signature Date Crothers, Simon, P.

    8/13/2015 A:.} /4-

    ..vl.-1-i Examiner Level NIA Signature Date Site Review e,z Date NIA t!..tll','.< /./.,Z,~v-- H) Lv.LZZ

    1. /.11'~ /(7-1-1,-

    Other Level NIA Signature Date ANH Review Signature Date NIA L..~

    • l'J\\A '-A~ A.,.J.A--i L -

    \\b\\-:a.,.\\ lS'"° RS-20-012 Attachment 6 I j Page 17

    \\.

    ~Exelon UT Calibratioru... "amination Site/Unit:

    BRW 2

    Procedure:

    ER-AA-335--030 Outage No.:

    I NIA Summary No.:

    NIA Procedure Rev.:

    4 I

    Report No.:

    UT-2015--006 Workscope

    PSI Work Order No.:

    01782044--02 Page:

    2 of 6

    Code:

    ASME 2001 Edition 12003 Addenda Cst./ltem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-15

    ==

    Description:==

    Flange to Elbow System ID:

    AF

    ~-----------------~-~-~--~~~-~~-------~--~~--~---~---~--..-~~~~~-

    Component ID: Field Weld 2 Size/Length:

    0.5" 114.1" Thickness/Diamete~

    0.337" 14" limitations:

    Single Sided Access Start Time:

    0953 Finish Time*

    1015 Instrument Settings Search Unit Cal.

    Axial Oriented Search tlnit nme Date Serial No.:

    0221JM Serial No.:

    SC1489 Checks Calibration Signal Sw~p Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech Initial Cal.

    0731 8/1312015 Reflector Amplitude%

    Division Sound Path Model:

    USN60SW linearity:

    2015-L--001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    1004 8/1312015 0.5" Notch 80%

    6.0 0.9" Delay:

    4.9803 Range:

    1.5" Freq.:

    5.0 MHz Center Freq.:

    NIA Inter. Cal.

    1012 8/1312015 NIA NIA Nlf4 NIA M'tlCalNel:

    0.1270 Pulser Type:

    Square Squint Angle:

    Inter. Cal.

    NIA NIA NIA Nlf4 NIA Exam Angle:

    &o*

    N/A Damping:

    5000hms Reject:

    Final Cal.

    1313 8113/2015 NIA NIA Nlf4 NIA O"lo Measured Angle:

    so*

    Mode:

    Shear PRF:

    Auto High SU Freq.:

    Couplant NIA NIA NIA NIA 5.0 MHz Exit Point 0.25"

    1. of Elements:

    1 Frequency:

    5.0MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Circumferential Oriented Search Unit Config.:

    Single Focus:

    NIA Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    33 Circ. Gain (dB):

    NIA 10 Screen Div. =

    1.5 in. of Sound Path Calibration Block Csl. Block No.

    BWD-PDl-516--02 Thickness 0.5" -2.0*

    Dia.:

    Flat cat. Blk. Temp. 84* Temp. Tool:

    29021141 Comp. Temp.

    sa* Temp. Tool:

    29021141 Recordable lndication(s):

    Yes~

    NoO Results:

    Accept,.,

    Reject O Percent Of Coverage Obtained > 90%:

    No-90"/o Type:

    Ultragel II Calibration Signal Sweep Sound Path Shape:

    Round Contour:

    NIA Mfg.:

    Sonotech Reflector Amplitude%

    Di~ion Wedge Style:

    MSW QC NIA NIA NIA NIA Search Unit Cable Exam Batch:

    13C028 NIA NIA Nlf4 NIA RG-174 6'

    No. Conn.: o Type:

    Ultragel II NIA NIA N/f4 NIA Type:

    Length: -

    Mfg.:

    Sonotech NIA NIA NIA NIA Scan Coverage Upstream O Downstream ~ Scan dB:

    39 --

    cwo CCW O Scan dB: NIA Exam Surface:

    OD Surface Condition:

    Ground (If Yes. Ref. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data:

    NIA Reference Block Reference/Simulator Block Serial No.:

    Type:

    Gain Signal Sweep Sound Path 142410CS dB Reflector Amplitude%

    Dl~ ion 1" Angle Beam 28 SDH 80%

    4:.3 0.64*

    N/A NIA NIA NIA NIA NIA NIA NIA NIA NIA Comments: Cal Block BWD-PDl-51~ demonstrated to be ultrasonically equivalent to Flaw Tech Cal Block 22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill

    ~ y_. - ~e Date Reviewer Signature Date i

    Crothers, Simon, P.

    8113/2015

    /ll/PI'-

    /(.///!-

    I Examiner Level NIA Signature Date Site Review Si~~

    ~

    Date NIA eJ,,,,'.s 11. At'-k""'6--1 Lv....o:T

    ~. #-~

    ~0-1'-,-_r Other Level NIA Signature Date ANll Review Signature Date NIA Lee-

    ~cJ1(3~~

    J_ Vi-

    • fl Difl*
    lO'l~b~

    RS-20-012 Attachment 6

    Page 18

    2"E'Xelon UT Calibratior11....<amination Site/Unit:

    BRW 2

    Procedure:

    ER*AA-335--030 Outage No.:

    NIA I

    Summaiy No.:

    NIA Procedure Rev.:

    4 Report No.:

    i UT *201 S-006 Workscope:

    PSI Work Order No.:

    01782044-02 Page:

    ~ 3 of 6

    Code:

    ASME 2001 Edition/ 2003 Addenda Cal./ltem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX*15

    ==

    Description:==

    Flange to Elbow System ID:

    AF


    ~-----

    Component ID: Field Weld 2 Thickness/Diameter.

    0.337* /4*

    Size/Length:

    o.s* / 14.1" Limitations:

    Single Sided Access Start Time:

    0953 Finish Timei 1015 Instrument Settings Search Unit Cal.

    Axial Oriented Search l!Jnit Time Date Serial No.:

    0221JM Serial No.:

    0112WB Checks Swttep Initial Cal.

    Calibration Signal Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech 0739 8/1312015 Reflector Amplitude%

    ~

    Model:

    USN60SW Linearity:

    2015-L-001 Size:

    0.25*

    Model:

    Comp-G Inter. Cal.

    1012 8/13/2015 o.s* Notch 80°4 7.6 1.52*

    Delay:

    6.2216 Range:

    2.0*

    Freq.:

    5.0MHz Center Freq.:

    NIA Inter. Cal.

    1018 8/13/2015 NIA NIA NIA NIA M'tlCalNel:

    0.1270 Pulser Type:

    Square Exam Angle:

    Squint Angle:

    Inter. Cal.

    NIA NIA N/A NIA NIA 70° N/A Damping:

    5000hms Reject:

    Final Cal.

    1314 811312015 NIA N/A NIA NIA 0%

    Measured Angle:

    71" Mode:

    Shear PRF:

    Auto High SU Freq.:

    5.0 MHz

    1. of Elements:

    Couplant NIA N/A NIA NIA Exit Point 0.3" 1

    Frequency:

    5.0MHz Rectify:

    Fullwave Config.:

    Single Focus:

    -- car. Batch:

    NIA 13C028 Circumferential Oriented Search Unit Voltage:

    450 Pulse Width:

    100 Ax. Gain {dB):

    42 Cire. Gain (dB):

    NIA 10 Screen Div.=

    2 in. of Sound Path Calibration Block cat. Block No.

    BWO-PDl*51&-o2 Thickness 0.5* -2.0*

    Dia.:

    Flat cat. Blk. Temp. ~

    Temp. Tool:

    29021141 Comp. Temp.

    _!!:..Temp. Tool:

    29021141 Recordable lndication(s):

    Yes O No~

    Results:

    Accept ~

    Reject O Percent Of Coverage Obtained > 90"k:

    No-90%

    Type:

    Ultragel II Sw~

    Shape:

    Contour:

    NIA Calibration Signal Sound Path Round Mfg.:

    Sonotech Reflector Amplitude%

    Divilfion Wedge Style:

    MSWQC NIA NIA NIA NIA Search Unit Cable Exam Batch:

    13C028 NIA NIA NIA NIA RG*174 6'

    No. Conn.: o Type:

    Ultragel II NIA NIA NIA NIA Type:

    Length: -

    Mfg.:

    Sonotech NIA N/A NIA NIA Scan Coverage Upstream O Downstream~ Scan dB:

    42 --

    cwo CCWO Scan dB: NIA Exam Surface:

    OD Surface Condition:

    Ground (If Yes, Ref. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data*

    NIA Reference Block Reference/Simulator B(ock Serial No.:

    Type:

    Gain Signal S~ep 142410 cs Sound Path dB Reflector Amplitude% Division 1" Angle Beam 41 SDH 80%

    5;0 1.0*

    NIA NIA NIA N(A NIA N/A NIA NIA NIA NIA Comments: Cal Block BWO-PDl-516-02 demonstrated to be ultrasonically equivalent to Flaw Tech Cill Block 22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill L

    ~

    Date Reviewer Signature

    ,,u/~

    Date Crothers, Simon, P.

    8/13/2015 A//'!-

    Examiner Level NIA Signature Date Site Review Signature

    ~

    Date NIA

    (!. /,/'#,/.s H.. /'7 G~t:,...#) l..u.Pr dYI~-

    /o-/*,-s-Other Level NIA Signature Date ANll Review Signature I

    Date J._ ~~

    NIA

    \\-E-e' \\"-'\\.~LA~~ ~

    Q.a

    \\Ob.. \\ *V'S-I RS-20-012 Attachment 6 1Page 19

    ~Exelon~

    Supplemental Report Report No.:

    UT-2015-006 Page:

    4 of 6

    - Summar:y-No,;..N/A*- * --* * * * - * **

    . J I

    I,.

    Sketch or Photo:

    Work Package: 01782044-02 Weld: FW-2 Sketch 1: Coverage Plot Weld Crown Width: 0.5" Counterbore US: None Counterbore OS: None Profile @ LO (Extrados)

    Scanned across weld with 45° probe, Flange coverage credit on far side of weld taken1_d~~~

    with higher angles.

    0 1"

    2" I

    I I

    Flow Note: 70° used to obtain remaining coverage, scan limited to area shown.

    Circ Coverage Coverage Cale:

    Axial Coverage = 100%

    Circ Coverage = 1.2" of 1.5" exam box width = 80%

    Total= (100% + 80%)/2 = 90%

    3" I

    d#~

    RS-20-012 Attachment 6

    £,(EUnJ '-" dZ

    /{.9

    • I-I~-

    ANI I ANH REVIEW

    \\o \\'\\..\\~

    REVIEW DATE +/---\\._I Oe Page 20

    ~Exelon.

    Supplemental Report Report No.:

    UT-2015..QO&

    Page:

    5 of 6

    Summary-No~ NIA-Sketch or Photo:

    j Work Package: 01782044-02 Weld: FW-2 Sketch 2: Indication Plot Profile @ LO (Extrados)

    Flange Flow

    (!) Root Geometry, seen intermittently 360° 0

    1" 2"

    3"

    '~ ----'----'l.____...___ _ _.l _ _...._____.I C /,,,-.'s H-/11'-K-eco,..

    eL-1-/ll v'--

    e ~w1(.) J.v tP 10 15 RS-20-012 Attachment 6 ANI I ANll REVIEW RFVIFW nATFd-""'-Jt.. 111. \\.o \\"'"'--\\ \\-S-Page 21

    ~Exelon, Ultrasonic Indication Report Site/Unit:

    BRW I

    2 Procedure:

    ER*AA-335-030 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    UT-2015-006 :

    Workscope:

    PSI Work Order No.:

    01782044-02 Page:

    6 of &:

    Wo W1111mc Search Unit Angle: --------

    Wo Location:

    Centerline 60 0

    @ Piping Welds O Ferritic Vessels

    ~ 2"T CL j

    W~ W2 Lo Location:

    Extrados 0 Other NIA

    .....-------<;,*, ?

    MP Metal Path w

    o*

    F Wo To S.U. At M.

    A I

    esponse I

    >--+-----: -DA11Jlrl

    =orward)

    • -rrr Lo
    !ackward)

    !_J

    • ~

    h :6 0 J, J, Comments:

    Field Weld2 WI ;~w,i Indication w

    Forward Backward L1 L

    l2 RBR Remarl<s Angle No.

    Of Max NIA Of Max NIA OfMax NIA Max NIA Amp.

    Of Of OAC w

    MP Wt MP W2 MP Max Max 60° 1

    100%

    0.1*

    0.82" NIA NIA NIA NIA NIA o*

    NIA Root Geometry from OS side.

    I NIA I

    I j

    I I

    i I

    I Examiner Level 111 - {)_ - - ~~e Date Reviewer Signature.I/In-+

    Date Crothers, Simon, P.

    811312015

    /{)I/?-

    Examiner Level NIA Signature Date Site Review l~gnature I

    Date I

    NIA A.... "/.< ~

    ~v*

    ...,,.. i.

    • Fii~# r Other Level NIA Signature Date ANllReview.J_ ~

    rSignature Date NIA lo l 'l..\\l\\S-RS-20-01 2 Attachment 6

    Page 22

    UT Calibratio.amination 2AF-03-23

    ~\\....

    ~Exelon.

    Site/Unit:

    BRW 2

    Procedure:

    ER*AA-335-030 Outage No.:

    I NIA Summary No.:

    N/A Procedure Rev.:

    4 Report No.:

    UT-2015-001 Workscope:

    PSI Work Order No.:

    01782044.()1 Page:

    i 1 of 6

    Code:

    ASME 2001 Edition/ 2003 Addenda Cat./ltem:

    NIA location:

    Steam Tunnel Drawing No.:

    FX-13

    ==

    Description:==

    Elbow to Flange System 10:

    AF

    ~~~~~~~~~~~~~~~~~~~~~--------------~~-~~--~--~--~--~-------------~-

    Component ID: Field Weld 1 Size/Length:

    0.9" / 14.1" Thickness/Diameter:

    0.337" / 4" limitations:

    Single Sided Access Start Time:

    0908 Finish Tim~ :

    0938 Instrument Settings Search Unit Cal.

    Axial Oriented Search !Jnit Time Date Serial No.:

    0221JM Serial No.:

    SC1493 Checks Initial Cal.

    Calibration Signal Sweep Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aero tech 0720 8113/2015 Reflector Amplitude%

    Division Model:

    USN 60 SW Linearity:

    2015-L--001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    0908 8/13/2015 0.5" Notch 80%

    7.2 0.72" Delay:

    3.5741 Range:

    1.0" Inter. Cal.

    0921 8/13/2015 NIA NIA NIA NIA Freq.:

    5.0 MHz Center Freq.:

    NIA Inter. Cal.

    M'tlCalNel:

    Pulser Type:

    N/A NIA NIA NIA N/A 0.1270 Square Exam Angle:

    45*

    Squint Angle:

    NIA Final Cal.

    1312 8113/2015 Damping:

    500 Ohms Reject:

    0%

    NIA NIA NiA N/A Measured Angle:

    46° Mode:

    Shear NIA NIA NIA NIA Couplant PRF:

    Auto High SU Freq.:

    5.0MHz Exit Point 0.2*

    1. of Elements:

    1 Circumferential Oriented Search Unit Frequency:

    5.0 MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Config.:

    Single Focus:

    NIA Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    21 Circ. Gain (dB):

    NIA 10 Screen Div. =

    1 in. of Sound Path Calibration Block Cal. Block No.

    BWD-PDl-516--02 Thickness o.5" - 2.0*

    Dia.:

    Flat Cal. Blk. Temp. 84° Temp. Tool:

    29021141 Comp. Temp. ~

    Temp. Tool:

    29021141 Results:

    Accept.,,

    D Reject O

    ~

    Percent Of Coverage Obtained > 90%:

    No-87%

    Examiner level Ill tJ.

    Crothers, Simon, P.

    A

    ~ -

    Examiner Level N/A NIA Other Level NIA N/A RS-20-012 Attachment 6 Type:

    Ultragel II Calibration Signal Sweep Sound Path Shape:

    Round Contour:

    NIA Reflector Amplitude%

    Divi~ion Mfg.:

    Sonotech Wedge Style:

    MSW QC Exam Batch:

    13C028 NIA N/A NJ.A NIA Search Unit Cable NIA NIA NI.A N/A Type:

    Ultragel II NIA N/A Ni_A N/A Type:

    RG-174 Length: 6' No. Conn.: 0 Mfg.:

    Sonotech Scan Coverage Upstream ~ Downstream O Scan dB:

    cw~

    CCW ~ Scan dB:

    Exam Surface:

    OD Surface Condition:

    Ground Info 0 Reviewed Previous Data:

    NIA

    ~

    Date 811312015 Signature Date NIA N/A NJ.A N/A 33 Reference Block Reference/Simulator Block

    -- Serial No.:

    Gain Signal Sweep Sound Path 39 142410 cs dB Reflector Amplitude% Division

    -- Type:

    p Reviewer Site Review 1" Angle Beam 21 SDH 50%

    4.5 0.45" N/A N/A NIA NJA NIA NIA NIA NIA NJA NIA Comments: Cal Block BWD-PDl-516-02 demonstrated to be ultrasonically equivalent to Flaw Tech Cal Block 22571.

    Baseline Exam.

    Weld Doc 2A.

    Signature Date

    /V/+

    /d//f- :

    Signature Date Ch h/"11£.s Ji, /??t:.~a~1 J i.vzzr d#/ht:-L

    /(>-/-/-~

    Signature Date ANll Review Signature Date l-Slr l'-lA \\..A~ t\\.N AN J_~._I!.

    \\ '.D-S--'S-1 Page 23

    ~Exelon UT Calibration1-JCamination Site/Unit:

    BRW 2

    Procedure:

    ER*AA-335-030 Outage No.:

    N/A Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    UT-2015-001 Workscope:

    PSI Work Order No.:

    01782044-01 Page: : 2 of 6

    Code:

    ASME 2001 Edition / 2003 Addenda Cat/Item:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-13

    ==

    Description:==

    Elbow to Flange System ID:

    AF

    ~--------------------------------------------------------------------------------------------------------------------,------------~

    Component ID: Field Weld 1 Size/Length:

    0.9" / 14.1" Thickness/Diameter:

    0.337" / 4" Limitations:

    Single Sided Access Start Time:

    0908 Finish Time:

    0938 Instrument Settings Search Unit Cal.

    Axial Oriented Search.Unit Time Date Serial No.:

    0221JM Serial No.:

    SC1489 Checks Calibration Signal Sweep Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech Initial Cal.

    0731 8/1312015 Reflector Amplitude%

    Division Sound Path Model:

    USN60SW Linearity:

    2015-L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    0921 811312015 0.5" Notch 80%

    sio 0.9" Delay:

    4.9803 Range:

    1.5" Freq.:

    5.0 MHz Center Freq.:

    NIA Inter. Cal.

    0930 8/1312015 NIA NIA N(A NIA M'tl CalNel:

    0.1270 Pulser Type:

    Square Inter. Cal.

    NIA NIA NIA

    ~A NIA Exam Angle:

    so*

    Squint Angle:

    NIA Final Cal.

    1313 8/13/2015 NIA NIA NiA NIA Damping:

    5000hms Reject:

    0%

    Measured Angle:

    so*

    Mode:

    Shear PAF:

    Auto High SU Freq.:

    Couplant NIA NIA NIA NIA 5.0 MHz Exit Point 0.25"

    1. of Elements:

    1 Frequency:

    5.0MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Circumferential Oriented Search Unit Conlig.:

    Single Focus:

    NIA Voltage:

    450 Pulse Width:

    100 Type:

    Ultragel II Calibration Signal Sweep Sound Path Shape:

    Round Contour:

    NIA Reflector Amplitude%

    Division Mfg.:

    Sonotech Wedge Style:

    MSWOC NIA NIA N/A NIA Ax. Gain (dB):

    33 Gire. Gain (dB):

    NIA Exam Batch:

    13C028 Search Unit Cable NIA NIA NIA N/A 10 Screen Div. '"'

    1.5 in. of Sound Path Type:

    RG-174 Length: S' No. Conn.: 0 Type:

    Ultragel II NIA NIA WA NIA Mfg.:

    Sonotech Calibration Block Scan Coverage NIA N/A NIA NIA Cal. Block No.

    BWD-PDl-516--02 Upstream~ Downstream O Scan dB:

    39 Reference Block Reference/Simulator Block Thickness 0.5" - 2.0" Dia.:

    Flat Gain Signal Sweep Sound Path cwo CCW O Scan dB: NIA Serial No.:

    142410 cs dB Reflector Amplitude% Oi\\!ision Cal. Blk. Temp. 84" Temp. Tool:

    29021141

    -- Type:

    1" Angle Beam Exam Surface:

    OD 28 SDH 80%

    4.3 O.S4" Comp. Temp.

    106° Temp. Tool:

    29021141 Surface Condition:

    Ground NIA NIA NIA N/A NIA Recordable lndication(s):

    Yes~

    NoO (If Yes, Ref. Attached Ultrasonic Indication Report.)

    NIA NIA NIA N/A NIA Results:

    Accept *""

    Reject O Info O Comments: Cal Block BWD-PDl-516-02 demonstrated to be ultrasonically equivalent to Flaw Tech Cal Block 22571.

    Baseline Exam. Weld Doc 2A.

    Percent Of Coverage Obtained > 90%

    • No-87%

    Reviewed Previous Data*

    NIA Examiner Level Ill~ ~

    Date Reviewer Signature m14-Date Crothers, Simon, P.

    8113/2015

    ~/4-Examiner Level NIA Signature Date Site Review

    ~nature ~

    i Date NIA C,),J-1,~ //./?1£,R'~Jt) Lv.D£-

    ("?,

    • #-,,11'}._

    . /P-1-1r Other Level NIA Signature Date ANll Review

    ~ignature I

    Date NIA L-e-e ~B.~~

    lA........Jl...Q lD-S"-~

    RS-20-012 Attachment 6 Page 24

    I,

    ~Exelon UT Calibratio"1..;xamination Site/Unit:

    BRW 2

    Procedure:

    ER*AA-335-030 Outage No.:

    NIA Summary No.:

    N/A Procedure Rev.:

    4 Report No.:

    UT-2015-001 Workscope:

    PSI Work Order No.:

    01782044-01 Page:

    3 of 6

    Code:

    ASME 2001 Edition I 2003 Addenda Cat./ltem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-13

    ==

    Description:==

    Elbow to Flange System ID:

    AF Component ID: Field Weld 1 Size/Length:

    0.9" / 14.1" Thickness/Diameter:

    0.337" / 4" Limitations:

    Single Sided Access Start Time:

    0908 Finish Tim~:

    0938 Instrument Settings Search Unit Cal.

    Time Date Axial Oriented Search.:unit Serial No.:

    0221JM Serial No.:

    0112WB Checks Calibration Signal Sweep Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB*Aerotech Initial Cal.

    0739 8/13/2015 Reflector Amplitude%

    Oivi~ion Sound Path Model:

    USN 60SW Linearity:

    2015-L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    0930 8/1312015 0.5" Notch 80o/o 1:6 1.52" Delay:

    6.2216 Range:

    2.0*

    Freq.:

    5.0 MHz Center Freq.:

    NIA Inter. Cal.

    0938 8/13/2015 NIA N/A NfA N/A M'tlCalNel:

    0.1270 Pulser Type:

    Square Squint Angle:

    Inter. Cal.

    N/A NIA N/A WA N/A Exam Angle:

    70" N/A Final Cal.

    1314 8/13/2015 NfA NIA N/A N/A Damping:

    5000hms Reject:

    Oo/o Measured Angle:

    71° Mode:

    Shear Couplant NIA NIA NIA NIA PRF:

    Auto High SU Freq.:

    5.0 MHz Exit Point 0.3"

    1. of Elements:

    1 Frequency:

    5.0MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Circumferential Oriented Search Unit Config.:

    Single Focus:

    N/A Voltage:

    450 Pulse Width:

    100 Shape:

    Round Contour:

    N/A Wedge Style:

    MSWQC Ax. Gain (dB):

    42 Gire. Gain (dB):

    NIA Search Unit Cable 10 Screen Div. =

    2 in. Of Sound Path Type:

    RG-174 Length: 6' No. Conn.: O Calibration Block Scan Coverage Cal. Block No.

    BWO-POl-516-02 Upstream ~ Downstream O Scan dB:

    42 Thickness o.5" - 2.0*

    Dia.:

    Flat cwo CCW O Scan dB: N/A Cal. Blk. Temp.

    84" Temp. Tool:

    29021141 Exam Surface:

    00 Comp. Temp.

    106° Temp. Tool:

    29021141 Surface Condition:

    Ground Recordable lndication(s):

    Yes O No~

    (If Yes, Ref. Attached Ultrasonic Indication Report.)

    Results:

    Accept ';i Reject O Info O Percent Of Coverage Obtained > 90%:

    No-87%

    Reviewed Previous Data:

    NIA Type:

    Ultragel II Calibration Signal Sweep Sound Path Mfg.:

    Sonotech Reflector Amplitude%

    Division Exam Batch:

    13C028 NIA NIA NIA N/A NIA NIA NIA N/A Type:

    Ultragel II NIA N/A N/A N/A Mfg.:

    Sonotech NIA N/A NIA NIA Reference Block Reference/Simulator Block Serial No.:

    Type:

    Gain Signal SY,Jeep Sound Path 142410 cs dB Reflector Amplitude o/o Division 1" Angle Beam 41 SOH 80%

    5.0 1.0" N/A N/A NIA NIA NIA N/A N/A NIA

    ~A N/A Comments: Cal Block BWD-PDl-516-02 demonstrat~d to be ultrasonically equivalent to Flaw Tech Qal Block 22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill

    .2.

    • A ~

    Date Reviewer Signature j

    Date Crothers, Simon, P.

    8/13/2015 tft)/,q_

    ,/Z//,r?-

    I Examiner Level N/A Signature Date Site Review

    ~re Date N/A

    e. J,JA, ~ J(. /?/ C.~t:j,-z)

    .t. v L2L

    1. 4;-y/____:.

    /CJ-/-/,

    Other Level NIA Signature Date ANll Review J__ Signature i

    Date NIA

    ~<::-e- ~~*~~

    v.......... ll<<.

    \\.0-.S--\\~

    RS-20-012 Attachment 6 Page 25

    1§7 Exelon.

    Supplemental Report Sumrnar:y.t-~o.: _N/A......

    Sketch or Photo:

    \\NorkPackage: 01782044-01

    \\Neid: FVV-1 Sketch 1: Coverage Plot

    \\Neid Crown \\Nidth: 0.9" Counterbore US: None Counterbore DS: None Profile @ LO (Extrados)

    Scanned across weld with 45° probe, coverage credit on far side of weld take with higher angles.

    0 I

    Flow 0.45" Report No.:

    UT-2015-001 Page:

    4 of 6

    1" 2"

    3" I

    lit..

    Note: 70° used to obtain remaining coverage, scan limited to area shown.

    Coverage Cale:

    Axial Coverage = 100%

    Circ Coverage= 1.4" of 1.9" exam box width= 74%

    c:,1,.,..~ Jl*n~-k~~,..~

    Total= (100% + 74%)/2 = 87%

    I I

    ~* #mc_:/4--

    )

    ~

    ~

    Exc~'"'-'*m 10-1-1r RS-20-012 Attachment 6 ANI I ANll REVIEW 1 0 ~\\ \\.<

    REVIEW DATE j_ ~ ~e 2s

    ~Exelon..

    .. Summary.l~o.: N/A.. _

    Sketch or Photo:

    Work Package: 01782044-01 Weld: FW-1 Sketch 2: Indication Plot Supplemental Report Flow 0 Root Geometry, seen intermittently 360° l

    /

    RS-20-012 Attachment 6 Report No.:

    UT-2015-001 Page:

    5 of 6

    Flange ANI I ANll REVIEW l 0 lS.-l l~

    REVIEW DATE,h ~-* -

    .=-Exelon, Ultrasonic Indication Report Site/Unit:

    BRW 2

    Procedure:

    ER-AA-335-030 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    UT-2015-001,

    Workscope:

    PSI Work Order No.:

    01782044-01 Page:

    6 of 5;

    Wo

    • Wmm:

    Search Unit Angle:

    ~~~~~~~~-

    W o Location:

    Centerline Lo Location:

    Extrados 60 0

    @ Piping Welds O Ferritic Vessels

    ~ 2"T 0 Other NIA

    ~L, l

    Wt W2 L SJ?~ I MP Metal Path w

    Dist F

    WoTo S.U. At M.

    R I

    esponse I

    ---i---------..;.--DATUM

    =orward)

    --rrr Lo 3ackward)

    ~

    ~. 6 Comments:

    Field Weld 1 J. l - ~h D

    Wit Wna.x Wi

    ~

    Indication w

    Forward Backward L1 L

    L2 ABA Remarks Angle No.

    Of Max NIA Of Max NIA Of Max NIA Max NIA Amp.

    Of Of DAC w

    MP W1 MP W2 MP Max Max

    &o*

    1 55%

    0.7" 0.9" NIA NIA NIA NIA NIA O"

    NIA NIA Root Geometry from US side.

    Examiner Level Ill ~~

    Date Reviewer Signature Date Crothers, Simon, P.

    8/13/2015

    /l//#-

    RtJ(~

    Examiner Level NIA Signature Date Site Review

    ~nature I

    Date NIA 1~14.I' U -S, rhv

    _J<_

    w~/.

    Other Level NIA Signature Date ANll Review I'

    'Signature Date NIA LCE" ~A-r-l J_ \\,..

    ~._

    \\o-S--\\~

    RS-20-012 Attachment 6

    Page 28

    2AF-03-24

    ~Ex*eton UT Calibratioruc.J<amination Site/Unit:

    BRW I

    2 Procedure:

    Summary No.:

    NIA Procedure Rev.:

    Workscope:

    PSI Work Order No.:

    Code:

    ASME 2001 Edition / 2003 Addenda Cat./ltem:

    NIA Drawing No.:

    FX-13

    ==

    Description:==

    Flange to Elbow System ID:

    AF ER*AA-335-030 4

    0178204<M>1 Location:

    Outage No.:

    NIA Report No.:

    UT*2015-002 Page:

    Steam Tunnel

    • 1 t

    of 6


    ........ ----~----

    Component ID: Field Weld 2 Size/Length:

    0.9" /14.1" Thickness/Diameter*

    0.33r / 4*

    Limitations:

    Single Sided Access Start Time:

    0908 Finish Time; 0938 Instrument Settings Search Unit Cal.

    Axial Oriented Search Qnlt Time Date Serial No.:

    0221JM Serial No.:

    SC1493 Checks Manufacturer:

    Initial Cal.

    calibration Signal Sweep Sound Palh GE Inspection Technologies Manufacturer:

    KB-Aerotech 0720 811312015 Reflector Amplitude%

    Division Inter. cal.

    0908 811312015 I

    Model:

    USN60SW "Linearity:

    2015-L-001 Size:

    0.25" Model:

    Comp-0 o.s* Notch 80%

    7.2 0.12*

    Delay:

    3.5741 Range:

    1.0*

    Inter. Cal.

    0921 8/1312015 NIA NIA NIA NIA Freq.:

    5.0 MHz Center Freq.:

    NIA M'tlCaWel:

    0.1270 Pulser Type:

    Square Inter. Cal.

    NIA NIA NIA NIA NIA Exam Angle:

    45° Squint Angle:

    NIA Final car.

    1312 8113/2015 Damping:

    5000hms Reject:

    0%

    Measured Angle:

    Mode:

    NIA NIA NIA NIA 46° Shear PRF:

    Couplant NIA NIA NIA NIA Auto High SU Freq.:

    5.0MHz Exit Point 0.2*

    1. of Elements:

    1 Frequency:

    5.0 MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Circumferential Oriented 58Jl'Ch Unit Config.:

    Single Focus:

    NIA Type:

    Ultragel II Calibration Signal SM!iep Voltage:

    450 Pulse Width:

    100 SoundPalh Shape:

    Round Contour:

    NIA Reflector Amplitude"/o Oivi$ian Mfg.:

    Sonotech Wedge Style:

    MSWQC NIA NIA NIA NIA Exam Batch:

    13C028 Ax. Gain (dB):

    21 Circ. Gain (dB):

    NIA Search Unit Cable NIA NIA NIA NIA 10 Type:

    Type:

    Ultragel II NIA NIA NIA NIA Screen Div. =

    1 in. of Sound Path RG-174 Length: 6' No. Conn.: ~ Mf.

    g..

    Sonotech NIA Calibration Block Scan Coverage NIA NIA NIA Cal. Block No.

    BWO.PDl-516-02 Upstream O Downstream~ Scan dB:

    33 Reference Block Reference/Simulator B~ock

    -- Serial No.:

    Gain Signal Sweep Thickness o.5" -2.0*

    Dia.:

    Flat cw~

    CCW ~ Scan dB:

    39 142410 cs dB Reflector Amplitude% Division Sound Path Cal. Bil<. Temp. 94* Temp. Tool:

    29021141 Exam Surface:

    OD Type:

    1" Angle Beam 21 SDH 50%

    4,5 o.4s*

    Comp. Temp. ~

    Temp. Tool:

    29021141 Surface Condition:

    Ground N/A NIA NIA NIA NIA NIA NIA N/A Nf A NIA 0

    ~

    p Results:

    Accept ~

    Reject O Info O Comments: Cal Block BWO.PDl*516-o2 demonstrated!to be ultrasonically equivalent to Flaw Tech Caf Block 22571.

    Baseline Exam.

    WeldDoc2A.

    Percent Of Coverage Obtained > 90%:

    No-37%

    Reviewed Previous Data:

    NIA Examiner Level Ill L_~

    Date Reviewer Signature

    ,V//

    Date Crothers, Simon, P.

    8/13/2015 A//4-

    /?.-

    Examiner Level N/A Signature Date Site Review dgnature Date NIA

    (!. '""'S )./, ftc:.~~;'l/ Lv..iJT

    • ,f~~

    /&> "J-Other Level NIA Signature Date ANll Review Signature Date NIA Lae:-~~~

    ~

    -V-.J I

    \\.cij-s--\\~

    RS-20-012 Attachment 6

    ~age 29

    &Exelon UT Calibratiori,... ~amination Sile/Unit:

    BRW I

    2 Procedure:

    ER-AA-335--030 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    UT-2015.Q02 Workscope:

    PSI Work Order No.:

    01782044-01 Page:

    2 of 6

    Code:

    ASME 2001 Edition I 2003 Addenda Cat.lltem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-13

    ==

    Description:==

    Flange to Elbow System ID:

    AF

    ~------------------------------------------------------------------------------------------------------------------.....;--------------

    Component ID: Field Weld 2 Size/Length:

    0.9" / 14.1

    • Thickness/Diametet 0.33r / 4*

    Limitations:

    Single Sided Access Start Time:

    0908 Finish Tim&:

    0938 Instrument Settings Search Unit Cal.

    Axial Oriented Search Unit Time Date Serial No.:

    0221JM Serial No.:

    SC1489 Checks Calibration Signal sweep Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech Initial Cal.

    0731 8/13/2015 Reflector Amplitude%

    Division Sound Palh Model:

    USN 60SW Linearity:

    2015-L-001 Size:

    0.25N Model:

    Comp-0 Inter. Cal.

    0921 8/1312015 o.5" Notch 80%

    6.0 0.9*

    Delay:

    4.9803 Range:

    1.5" Freq.:

    5.0 MHz Center Freq.:

    NIA Inter. Cal.

    0930 8113/2015 NIA NIA Nlft NIA M'UCalNel:

    0.1270 Pulser Type:

    Square Inter. Cal.

    N/A NIA NIA Hl!t NIA Exam Angle:

    60" Squint Angle:

    NIA Damping:

    5000hms*

    Reject:

    Final Cal.

    1313 8/1312015 NIA NIA NIA NIA 0%

    Measured Angle:

    so*

    Mode:

    Shear NIA PRF:

    Auto High SU Freq.:

    5.0 MHz Couplant NIA N/A NIA Exit Point 0.25"

    1. of Elements:

    1 Frequency:

    5.0MHz Rectify:

    Fullwave Config.:

    Single Focus:

    NIA Cal. Batch:

    13C028 Circumferential Oriented Search Unit Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    33 Circ. Gain (dB):

    NIA 10 Screen Div. =

    1.5 in. of Sound Path Calibration Block Cal. Block No.

    BWD*PDl*516-02 Thickness o.5" -2.0*

    Dia.:

    Flat Cal. Blk. Temp. 84" Temp. Tool:

    29021141 Comp. Temp.

    10s* Temp. Tool:

    29021141 Recordable lndicatlon(s):

    Yes~

    NoO Results:

    Accept.,,

    Reject O Percent Of Coverage Obtained > 90%:

    No-87%

    Shape:

    Contour:

    Type:

    Ultragel II Calibration Signal Sweep

    $ound Path Round NIA Mfg.:

    Sonotech Reflector Amplitude%

    Division Wedge Style:

    MSWQC NIA NIA NIA NIA Search Unit Cable Exam Batch:

    13C028 NIA NIA NIA NIA RG-174 6'

    No. Conn.: o Type:

    Ultragel II NIA NIA NIA Type:

    Length:

    Nl'f4 Mfg.:

    Sonotech NIA NIA NIA NIA Scan Coverage Upstream O Downstream~ Scan dB:

    39 --

    cwo CCW 0 Scan dB: NIA Exam Surface:

    OD Surface Condition:

    Ground (If Yes, Ref. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data:

    NIA Reference Block Reference/Simulator Biock Serial No.:

    Type:

    Gain Signal s weep Sound Path 142410CS dB Reflector Amplitude% Division 1

    • Angle Beam 28 SDH 80%

    413 0.64" NIA NIA NIA NIA NIA N/A NIA NIA NIA NIA Comments: Cal Block BWD-PDl-51&-02 demonstrated to be ultrasonically equivalent to Flaw Tech Cal Block 22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level lQ

    -~

    Date Reviewer Signature Date Ill Crothers, Simon, P.

    ~

    8/13/2015

    /V/~

    .v/n1 Examiner Level NIA Signature Date Site Review d: Signature Date NIA

    <!,. /,,,~ :S JI. AIG Ke R ;t.I

    ~~...zzr

    1. /;77,£-.k'~
    /c>-1-/~-

    Other Level NIA Signature Date ANll Review Signature I

    Date NIA

    ~

    \\'-\\.A-~~ lrN ~ l.-. \\.--'--.~.a...

    \\.. ~ -.S-_, s-RS-20-01 2 Attachment 6 ihage 30

    £!'!' E~elon Site/Unit:

    BRW 2

    UT Calibration/.... JC:amination Procedure:

    ER-AA-335--030 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    UT-2015-002 Workscope:

    PSI Work Order No.:

    01782044-01 Page:

    • 3 of 6

    Code:

    ASME 2001 Edition/ 2003 Addenda Cat./ltem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-13

    ==

    Description:==

    Flange to Elbow System ID:

    AF

    ~----------------------------------------------------------------------------------------------------------------------------

    Component ID: Field Weld 2 Size/l.ength:

    0.9" / 14.1" Thickness/Oiamete~

    0.33r 14" Limitations:

    Single Sided Access Start Time:

    0908 Finish Timei 0938 Instrument Settings Search Unit Cal.

    Axial Oriented Search Unit Time Date Serial No.:

    0221JM Serial No.:

    0112WB Checks Calibration Signal Initial Cal.

    Sweep Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech 0739 811312015 Reflector Amplitude%

    Division Model:

    USN60SW Linearity:

    2015-L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    0930 811312015 0.5" Notch 80'Yo 7.!)

    1.52" Delay:

    6.2216 Range:

    2.0*

    Freq.:

    5.0 MHz Center Freq.:

    NIA Inter. Cal.

    0938 811312015 NIA NIA NIA NIA M'tlCalNel:

    0.1270 Pulser Type:

    Square Exam Angle:

    Squint Angle:

    Inter. Cal.

    NIA NIA NIA NI~

    NIA 10*

    NIA Damping:

    5000hms Reject:

    Final Cal.

    1314 8113/2015 NIA NIA NIA NIA 0%

    Measured Angle:

    71*

    Mode:

    Shear PRF:

    Auto High SU Freq.:

    5.0MHz

    1. of Elements:

    Couplant NIA NIA NI~

    NIA Exit Point 0.3" 1

    Frequency:

    5.0 MHz Rectify:

    Fullwave Config.:

    Single Focus:

    -- Cal. Batch:

    NIA 13C028 Circumferential Oriented Se.. rch Unit Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    42 Circ. Gain (dB):

    N/A 10 Screen Div. =

    2 in. of Sound Path Calibration Block Cal. Block No.

    BWD-PDl-516-02 Thickness 0.5" -2.0*

    Dia.:

    Flat Cal. Blk. Temp. 84" Temp. Tool:

    29021141 Comp. Temp. ~

    Temp. Tool:

    29021141 Recordable lndication(s):

    Yes O No~

    Results:

    Accept.,

    Reject O Percent Of Coverage Obtained > 90%:

    No-87%

    Shape:

    Contour:

    Type:

    Ultragel II Calibration Signal Sweep Sound Path Round NIA Mfg.:

    Sonotech Reflector Amplitude%

    OiviSlon Wedge Style:

    MSW QC NIA NIA NIA NIA Exam Batch:

    13C028 Search Unit Cable NIA NIA NIA NIA RG-174 6' No. Conn.: O Type:

    Ultragel II NIA NIA NIA NIA Type:

    Length: -

    Mfg.:

    Sonotech NIA NIA NIA NIA Scan Coverage Upstream O Downstream~ Scan dB:

    42 --

    cwo CCWO ScandB: NIA Exam Surtace:

    OD Surtace Condition:

    Ground (If Yes, Ref. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data:

    NIA Reference Block Reference/Simulator Biock Serial No.:

    Type:

    Gain Signal S"<8eP Sound Path 142410 cs dB Reflector Amplitude% Division 1" Angle Beam 41 SDH 80%

    sio 1.0*

    N/A NIA NIA NJA NIA NIA NIA NIA N(A NIA I

    Comments: Cal Block BWD-PDl-516-02 demonstrated to be ultrasonically equivalent to Flaw Tech Cal Block 22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill.f. ~

    Date Reviewer Signature Date Crothers, Simon, P.

    811312015

    /O/n-A//~

    Examiner Level NIA Signature Date Site Review d

    Signature Date NIA e.~~~,'.s //. m~~a.,!t} J..v77L

    • ~/?,!_~

    /0-1-/r Other Level NIA Signature Date ANll Review

    ~Signature Date NIA I

    \\...c.::-e- ~~~

    v...... QAI

    ~.o--s;" -\\~

    RS-20-012 Attachment 6 P;age 31

    ~*Exelon.

    Supplemental Report

    .mmary No.: NIA Sketch or Photo:

    Work Package: 01782044-01 Weld: FW-2 Sketch 1: Coverage Plot Weld Crown Width: 0.9" Counterbore US: None Counterbore OS:

    None Profile @ LO (Extrados)

    Scanned across weld with 45° probe, coverage credit on far side of weld taken with higher angles.

    0 I

    Flow Report No.:

    UT-2015-002 Page:

    4 of 6 (

    1" 2n 3n I

    I I

    Note: 70° used to obtain remaining coverage, scan limited to area shown.

    Coverage Cale:

    Axial Coverage = 100%

    a J,,,,'J IJ. 14'1< k,ep.A)

    Circ Coverage= 1.4" of 1.9" exam box width= 74%

    dw~~,(_.

    ..

    • E.;(f{J.pf;c/. !-~"'!!-.. ~Q.-,,./?....

    Total:: (100% + 74%)/2 = 87%

    RS-20-012 Attachment 6 ANI I ANH REVIEW l"'l"h REVIEW OATEbbt~*.

    Page 32

    ~*Exelon.

    Supplemental Report

    .* nmary No.: NIA Sketch or Photo:

    Work Package: 01782044-01 Weld: FW-2 Sketch 2: Indication Plot Profile@ LO (Extrados)

    Flange Flow

    @Root Geometry, seen intermittently 360° Report No.:

    UT-2015.002 Page:

    5

    /'

    of 6

    • 0 1"

    2" 3"

    el,,,,'s II /?/ck~"-/J I.__ ____._ __

    I ___.__.__I __.______.I d

    1. 1?/H~

    L ~

    C:l(£l<'N'"'°' 10-1-1r ANI I ANll REVIEW

    \\

    REVIEWDATE~~L~"'l> ~

    RS-20-012 Attachment 6 Page 33

    Exelon.

    Ultrasonic Indication Report Site/Unit:

    BRW I

    2 Summary No.:

    NIA Workscope:

    PSI 60 Search Unit Angle: --------

    0 Wo Location:

    Centerline Lo Location:

    Extrados I

    MP Metal Path w

    Dist Comments:

    FieldWeld2 Indication w

    Forward Angle No.

    Of Max NIA Of Max OAC w

    MP W1 MP 60" 1

    60%

    0.7" o.aa*

    NIA NIA Examiner Level 111 - f)_ -

    ~****-

    Crothers, Simon, P.

    11,. -

    ~.../

    Examiner Level NIA Signature NIA Other Level NIA Signature NIA RS-20-012 Attachment 6 Procedure:

    ER-AA-335-<>30 Procedure Rev.:

    4 Work Order No.:

    01782044-01

    @ Piping Welds O Ferritic Vessels.?. 2"T 0 Other NIA F

    WoToS.U.AtM.

    R esponse

    =orward) 3ackward)

    Backward L1 L

    l2 RBR NIA Of Max NIA Max NIA Amp.

    Of Of W2 MP Max Max NIA NIA NIA o*

    NIA NIA Date Reviewer 8/13/2015

    /V/AL-Date Site Review J..1.- _,.~

    ~~\\,i Date ANll Review I

    Outage No.:

    NIA Report No.:

    UT*2015-002 :

    Page:

    6 of 6

    -irr J, J -

    Wo CL l

    i '

    w-W:ll W2

    --~-------~--DATUM lo

    ~

    ~b

    b 0 WI I w.u W':l

    ~

    Remarks Root Geometry from OS aide.

    I Signature Date

    ...v/~

    1lJatu::

    I Date 1~11;-

    Signature t>ate

    '-.cC'" ~~~~

    i.. \\A.._.: Q

    ~o-S"'-\\:S""° P.age 34

    2AF-04-20

    ~E'xeton UT Calibratiorn... JCamination Site/Unit:

    BRW 2

    Procedure:

    ER*AA-335-030 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    '. UT-2015-003 Woa1(scope:

    PSI Work Order No.:

    01782044-01 Page:

    1 of 8

    Code:

    ASME 2001 Edition I 2003 Addenda Catlltem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-13

    ==

    Description:==

    Elbow to Flange System ID:

    AF

    ~~~~~~~~~----~~~~~~~~~~-~------------------------------~~

    ...... ~~~~~~

    Component ID: Field Weld 3 Size/Length:

    o.1* 114.1*

    Thickness/Diameter:

    0.33r /4*

    Limitations:

    Single Sided Access Start Time:

    1032 Finish Time1 1131 Instrument Settings Search Unit Cal.

    Axial Oriented Search ~nit Time Date Serial No.:

    0221JM Serial No.:

    SC1493 Checks Initial Cal.

    Calibration Signal Sw*p SOund Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech 0720 8/1312015 Reflector Amplitude%

    Divi~

    Model:

    USN60SW Linearity:

    2015-L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    1032 8/13/2015 o.5* Notch 80%

    7~

    0.12*

    Delay:

    3.5741 Range:

    1.0*

    Inter. Cal.

    1056 8/13/2015 NIA NIA NIA NIA Freq.:

    5.0 MHz Center Freq.:

    NIA M'llCalNel:

    0.1270 Pulser Type:

    Square Inter. Cal.

    N/A NIA NIA NIA NIA Exam Angle:

    45° Squint Angle:

    NIA Final Cal.

    1312 8/13/2015 NIA NIA NIA NIA Damping:

    5000hms Reject:

    0%

    Measured Angle:

    46° Mode:

    Shear Couplant NIA NIA NIA NIA PRF:

    Auto High SU Freq.:

    5.0MHz Exit Point 0.2*

    1. of Elements:

    1-Cal. Batch:

    Frequency:

    5.0MHz Rectify:

    Fullwave 13C028 Circumferential Oriented Search Unit Config.:

    Single Focus:

    N/A Voltage:

    450 Pulse Width:

    100 Type:

    Ultragel II Calibration Signal Sw~ep SoundPalh Shape:

    Round Contour:

    NIA Reflector Amplitude%

    DiviSion Mfg.:

    Sonotech Wedge Style:

    MSW QC Exam Batch:

    13C028 NIA NIA NIA NIA Ax. Gain (dB):

    21 Circ. Gain (dB):

    NIA Search Unit Cable NIA NIA NIA NIA Type:

    Ultragel II NIA NIA NIA NIA 10 Screen Div. =

    1 In. Of Sound Path Type:

    RG-174 Length: 6' No. Conn.:.2_ Mf.

    g..

    Sonotech Scan Coverage NIA NIA NI~

    NIA Calibration Block Cal. Block No.

    . BWD-PDl-51&-02 Upstream~ Downstream O Scan dB:

    33 Reference Block Reference/Simulator Bl'ock

    -- Serial No.:

    Gain Signal Sweep Sound Palh Thickness 0.5*. 2.0*

    Dia.:

    Flat cw~

    CCW ~ Scan dB:

    39 142410 cs dB Reflector Amplitude% Division Cal. Blk. Temp. ~

    Temp. Tool:

    29021141 Exam Surface:

    OD

    -- Type:

    1

    • Angle Beam 21 SDH 50"/o 4.5 0.45*

    Comp. Temp. ~

    Temp. Tool:

    29021141 Surface Condition:

    Ground NIA NIA NIA N(A NIA

    ~

    port.)

    NIA NIA NIA NIA NIA Results:

    Accept..,,

    0 Reject O Info O Comments: Cal Block BWD-PDl-51&-02 demonstrated*to be ultrasonically equivalent to Flaw Tech Cal Block 22571.

    Baseline Exam.

    WeldDoc2A.

    Percent Of Coverage Obtained > 90%:

    No-88%

    Reviewed Previous Data:

    NIA Examiner Level Ill

    .~. ~

    Date Reviewer Signature i

    Date Crothers, Simon, P.

    8/13/2015 N/ /l})//1-Examiner Level NIA Signature Date Site Review dgnature Data NIA

    (!. /,~~-" N*PIC*~&

    f.1)

    ~v.LZZ

    • ~/~ /0-/-/S-

    .,g ""-

    Other Level NIA Signature Date ANll Review Signature I

    Date NIA Lt=-,;: M~~~

    k\\r-.12.

    lO,~~t\\S-RS-20-012 Attachment 6 Rage 35

    ~;Exelon UT Calibration1... JCamination

    \\. *.

    Site/Unit:

    BRW I

    2 Procedure:

    ER-AA-335-o30 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    UT*201~3 Workscope:

    PSI Work Order No.:

    01782044-01 Page:

    2 of 6

    Code:

    ASME 2001 Edition/ 2003 Addenda CatJltem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX*13

    ==

    Description:==

    Elbow to Flange System ID:

    AF

    ~---------------------------------------------------------....... -------

    Component ID: Field Weld 3 Size/Length:

    o.7" / 14.1" Thickness/Diametef:

    0.331* 14*

    Limitations:

    Single Sided Access Start Time:

    1032 Finish Time!

    1131 Instrument Settings Search Unit Cal.

    Time Date Axial Oriented Search Unit Serial No.:

    0221JM Serial No.:

    SC1489 Checks Calibration Signal Sweep Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB*Aerotech Initial Cal.

    0731 8/13/2015 Reflector Amplitude%

    Divi!lion Sound Path Model:

    USN60SW Linearity:

    2015*L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    1056 8/13/2015 0.5" Notch so*.-

    6.~

    0.9*

    Delay:

    4.9803 Range:

    1.5" Freq.:

    5.0MHz Center Freq.:

    NIA Inter. Cal.

    1126 8/13/2015 NIA NIA NJ!'

    NIA M'tlCalNel:

    0.1270 Pulser Type:

    Square Inter. Cal.

    NIA NIA NIA NIA NIA Exam Angle:

    60" Squint Angle:

    N/A Damping:

    5000hms Reject:

    Final Cal.

    1313 8/13/2015 NIA N/A NIA NIA 0%

    Measured Angle:

    60° Mode:

    Shear PRF:

    Auto High SU Freq.:

    Couplant NIA N/A NIA NIA 5.0 MHz Exit Point 0.25"

    1. of Elements:,

    Frequency:

    5.0 MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Circumferential Oriented Search Unit Config.:

    Single Focus:

    N/A Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    33 Circ. Gain (dB):

    NIA 10 Screen Div. =

    1.5 in. of Sound Path Calibration Block Cal. Block No.

    BWD-PDl*516-02 Thickness 0.5". 2.0" Dia.:

    Flat Cal. Blk. Temp. 84° Temp. Tool:

    29021141 Comp. Temp.

    100° Temp. Tool:

    29021141 Recordable lndication(s):

    Yes~

    NoO Results:

    Accept..,.

    Reject O Percent 01 Coverage Obtained > 90%:

    No-88%

    Shape:

    Type:

    Ultragel II Calibration Signal Sweep Sound Path Round Contour:

    NIA Mfg.:

    Sonotech Reflector Amplitude%

    OiviSion Wedge Style:

    MSW QC NIA NIA NIA NIA Search Unit Cable Exam Batch:

    13C028 NIA NIA NIA NIA RG*174 6'

    No. Conn.: o Type:

    Ultragel II NIA NIA NIA NIA Type:

    Length: -

    Mlg.:

    Sonotech NIA NIA NIA NIA Scan Coverage Upstream ~ Downstream O Scan dB:

    39 --

    cwo CCW O Scan dB: N/A Exam Surface:

    OD Surface Condition:

    Ground (If Yes, Ref. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data:

    NIA Reference Block Reference/Simulator Block Serial No.:

    Type:

    Gain Signal Sweep Sound Path 142410 cs dB Reflector Amplitude% Oiv!i;ion 1

    • Angle Beam 28 SDH 8094 413 0.64*

    NIA NJA NIA N/A NIA NIA NIA NIA NIA NIA Comments: Cal Block BWD*PDl-516-02 demonstrateit to be ultrasonically equivalent to Flaw Tech tj.1Block22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill

    ~ p _... -~

    Date Reviewer Signature Date Crothers, Simon, P.

    8113/2015

    ~/19-

    /Vlh+-

    I Examiner Level NIA Signature Date Sile Review d94/ft_~.

    Date NIA C /,l','S J/. fllr:.Ke"n/ t.v17L

    /O-i-/~

    Other Level Signature Date ANll Review Signature Date N/A 3-NIA L.C"C:. µ~~.0- --1

    \\A.-.

    ~ ~

    ~e>-'S:'° \\ ~

    RS-20-012 Attachment 6 Page 36

    ~T Exelon.

    Sile/Unit:

    BRW I

    2 Summary No.:

    NIA Workscope:

    PSI Code:

    ASME 2001 Edition I 2003 Addenda Drawing No.:

    FX-13 UT Calibratiorl,....acamination Procedure:

    ER*AA-33S-030 Procedure Rev.:

    4 Work Order No.:

    01782044-01 Cat./ltem:

    NIA Location:

    ==

    Description:==

    Elbow to Flange Outage No.:

    NIA Report No.:

    UT-201~

    Page:

    3

    ~

    Steam Tunnel of 6

    Sys~mlD:

    _AF.:__ ________________________________________________________________________________________ -:::-~---::-~---:-----:-::~-:--

    Component ID: Field Weld 3 Size/Length:

    0.7" / 14.1*

    Thickness/Diameter.

    0.33r 14*

    Limitations:

    Single Sided Access Start Time:

    1032 Finish Time:

    1131 Instrument Settings Search Unit Cal.

    Axial Oriented Search l,Jnit Time Date Serial No.:

    0221JM Serial No.:

    0112WB Checks calibration Signal sweep Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech Initial Cal.

    0739 8/13/2015 Reflector Amplitude%

    Oivi~ion Sound Path Model:

    USN60SW Linearity:

    2015-L~1 Size:

    0.25*

    Model:

    Comp-G Inter. Gal.

    1126 811312015 o.5* Notch 80%

    7.6 1.s2*

    Delay:

    6.2216 Range:

    2.0" Freq.:

    5.0MHz Center Freq.:

    NIA Inter. Cal.

    1131 811312015 NIA NIA NIA NIA MilCalNel:

    0.1270 Pulser Type:

    Square Exam Angle:

    Squint Angle:

    Inter. Cal.

    NIA NIA NIA NIA NIA 10*

    N/A Damping:

    5000hms Reject:

    Final Cal.

    1314 8/13/2015 NIA NIA NIA NIA 0%

    Measured Angle:

    71*

    Mode:

    Shear PRF:

    Couplant NIA NIA NIA NIA Auto High SU Freq.:

    5.0 MHz Exil Point 0.3*

    1. of Elements:

    1 Frequency:

    5.0MHz Rectify:

    Fullwave Config.:

    Single

    -- Cal. Batch:

    13C028 Circumferential Oriented Search Unit Focus:

    NIA Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    42 Circ. Gain (dB):

    N/A 10 Screen Div. =

    2 in. of Sound Path Calibration Block Cal. Block No.

    BWD-PDl-516--02 Thickness o.5* -2.0*

    Dia.:

    Flat Cal. Blk. Temp. ~

    Temp. Tool:

    29021141 Comp. Temp.

    100* Temp. Tool:

    29021141 Recordable lndlcalion(s):

    Yes O No~

    Results:

    Accept.,

    Reject O Percent Of Coverage Obtained > 90"4:

    No-88%

    ~ ~

    ~

    Shape:

    Contour:

    Type:

    Ultragel II Calibration Signal sweep Sound Path Round NIA Mfg.:

    Sonotech Reflector Amplitude%

    Division Wedge Style:

    MSW QC NIA NIA NIA NIA Search Unit Cable Exam Batch:

    13C028 NIA NIA NIA NIA RG-174 6' No. Conn.: o Type:

    Ultragel II NIA NIA NIA NIA Type:

    Length: -

    Mfg.:

    Sonotech NIA N/A NIA NIA Scan Coverage Upstream~ Downstream O Scan dB:

    42 cwo CCWO Scan dB: NIA Exam Surface:

    OD Surface Condition:

    Ground (If Yes, Ref. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data:

    NIA Reference Block Reference/Simulator B!ock Serial No.:

    Type:

    Gain Signal Sweep Sound Path 142410CS dB Reflector Amplitude% Oiv!slon 1

    • Angle Beam 41 SDH 80%

    5,0 1.0*

    NIA NIA N/A NiA NIA N/A NIA N/A NIA NIA Comments: Cal Block BWD-PDl*51&-02 demonstrated to be ultrasonically equivalent to Flaw Tech C11l Block 22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill _f

    ~

    Date Reviewer Signature Dale

    ///~

    Crothers, Simon, P.

    8/13/2015

    ////n-Examiner Level NIA Signature Date Site Review c2na;;t /?/J_;

    Date NIA

    ~l.tt,'.$ ;/. /?l"k<aw L~L1£ 10-1-1r Other Level NIA Signature Date ANll Review Signature I

    Date g__ LA NIA L...ee

    ~A-l.o.*T"b~~

    '..o-S"-'\\S-RS-20-012 Attachment 6

    ~age 37

    ~Exelon Supplemental Report

    . *"Summary.No.;. NIA-- - **

    /

    Sketch or Photo:

    Work Package: 01782044-01 Weld: FW-3 Sketch 1: Coverage Plot Weld Crown Width: 0.7" Counterbore US: None Counterbore OS: None Scanned across weld with 45° probe, coverage credit on far side of weld take*

    with higher angles.

    0 I

    Flow Report No.:

    UT *2015-003 Page:

    4 of 6

    1" 2"

    3" I

    I I

    Note: 70° used to obtain remaining coverage, scan limited to area shown.

    )

    Circ Coverage Coverage Cale:

    Axial Coverage = 100%

    a,,,,,~ # /11"~n-d Circ Coverage= 1.3" of 1.7" exam box width= 76.5% d 1'j /}1~A--

    Total= (100% + 76.5%)/2 = 88%

    LUL RS-20-012 Attachment 6

    £,(f;l()M ~vOL,1<:7-l

    • lf ANI I ANll REVIE~cl:'\\\\~

    OC\\llC\\AI nAT&= J_P~ _

    ~Exelon~

    Supplemental Report Report No.:

    UT-2015-003

    'Summas:y No.:. NIA * -

    Page: __!._ of 6

    -~* *

    )

    Sketch or Photo:

    Work Package: 01782044-01 Weld: FW-3 Sketch 2: Indication Plot Profile @ 3.5" CW Flow 0.44" 0.44" 0.44" 0.42" 0.48"

    (!)Root Geometry, seen intermittently 360° Flange

    @Geometric reflector from ID mismatch, seen intermittently 360°.

    RS-20-012 Attachment 6 Flange was open at the time of inspection, inspector verified this condition visually.

    Exelon.

    Ultrasonic Indication Report Site/Unit:

    BRW I

    2 Procedure:

    ER*AA-335-030 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    UT-2015-003.

    Workscope:

    PSI Work Order No.:

    01782044-01 Page:

    6 of I

    Wo w-

    ~L Wll W2

    ~

    Search Unit Angle: --------

    Wo Location:

    Centerline 60 0

    @ Piping Welds O Ferritic Vessels

    ~ 2*r Lo Location:

    Extradose 0 Other NIA MP Metal Path I

    esponse I

    -l1f

    -~----~ATUM

    =orward)

    I J.o 3ackward)

    ~~ b.6 0 J, J, -

    Comments:

    Field Weld3 WI ;WJau; WI!

    Wo To S.U. At Maxi A

    Indication w

    Forward Backward Ll L

    L2 RBR Remarks NIA NIA Angle No.

    Of Max NIA Of Max NIA Of Max Of Max Of Amp.

    DAC w

    MP W1 MP W2 MP Max Max 60" 1

    80%

    0.6" 0.88" NIA NIA NIA NIA NIA 3.5" NIA NIA Root Geometry from US side.

    I 60" 2

    55%

    0.8" o.ao*

    NIA NIA NIA NIA NIA 3.5" NIA NIA ID Geometry, see Indication Plot.

    I Examiner Level 111

    ~,(J

    ~

    Date Reviewer Mt#-

    Signature 4//,4-Date Crothers, Simon, P.

    8113/2015 Examiner Level NIA Signature Date Site Review 1:?~.-----

    Date NIA M'-"f' v. ~

    .. hhv

    'f/l"lir Other Level NIA Signature Date ANll Review Signature i

    "Date NIA L~~ \\'.A.""-A\\~,..._,~

    j_ "' c..

    '~-s-,s-I I

    I RS-20-012 Attachment 6 Page 40

    2AF-04-21 UT Calibration1.. xamination

    \\._

    ~" Exelon Site/Unit:

    BRW 2

    Procedure:

    ER*AA-335-030 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    UT*2015-o04 Workscope:

    PSI Wor1< Order No.:

    01782044-01 Page:

    1 of 6

    Code:

    ASME 2001 Edition / 2003 Addenda Cat./llem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX-13

    ==

    Description:==

    Flange to Elbow SysmmlO:

    ~A~F--------------------------------------------~~---::"."""-"'"'"!----:-:~':':"'-

    Component ID: Field Weld 4 Size/Length:

    0.7" / 14.1" ThicknesslDiametef:

    0.33r 14" Limitations:

    Single Sided Access Start Time:

    1032 Finish Tim~:

    1131 Instrument Settings Search Unit Cal.

    Time Date Axial Oriented Search Unit Serial No.:

    0221JM Serial No.:

    SC1493 Checks Initial Cal.

    Calibration Signal Sweep Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB*Aerotech 0720 8/13/2015 Reflector Amplitude%

    Oivi$ion Model:

    USN60SW Linearity:

    2015*L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    1032 8/13/2015 0.5" Notch 80%

    1.r.z 0.12*

    Delay:

    3.5741 Range:

    1.0*

    Inter. Cal.

    1056 8113/2015 NIA NIA NIA NIA Freq.:

    5.0MHz Center Freq.:

    NIA M'tiCaWel:

    0.1270 Pulser Type:

    Square Inter. Cal.

    N/A NIA NIA NIA NIA Exam Angle:

    45° Squint Angle:

    NIA Final Cal.

    1312 8/13/2015 Damping:

    5000hms Reject:

    0%

    NIA NIA NIA NIA Measured Angle:

    46° Mode:

    Shear PRF:

    Couplant NIA NIA NIA NIA Auto High SU Freq.:

    5.0 MHz Exit Point 0.2*

    1. of Elements:

    1 Frequency:

    5.0MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Circumferential Oriented Search Unit Config.:

    Single Focus:

    NIA Voltage:

    450 Pulse Width:

    100 Type:

    Ultragel II Calibration Signal Sweep Sound Path Shape:

    Round Contour:

    NIA Reflector Amplitude%

    Dlvi,ion Mfg.:

    Sonotech Wedge Style:

    MSWQC NIA NIA NIA NIA Exam Batch:

    13C028 Ax. Gain (dB):

    21 Circ. Gain (dB):

    NIA Search Unit Cable Type:

    NIA NIA NIA NIA Ultragel II NIA NIA Ni.A NIA 10 Screen Div. =

    1 in.of Sound Path Type:

    RG*174 Length:

    6' No. Conn.: ~ Mt.

    Sonotech g..

    NIA NIA NIA NIA Scan Coverage Calibration Block Cal. Block No.

    BWO-PDl*516.Q2 Upstream O Downstream~ Scan dB:

    33 Reference Block Reference/Simulator Block Gain Signal Sweep Sound Path Thickness 0.5" -2.0*

    Dia.:

    Flat cw~

    CCW ~ Scan dB:

    39 Serial No.:

    142410CS dB Reflector Amplitude%

    D~ion Cal. Blk. Temp. 84° Temp. Tool:

    29021141 Exam Surface:

    OD

    -- Type:

    1" Angle Beam 21 SDH 50%

    4'.5 0.45" Comp. Temp. ~

    Temp. Tool:

    29021141 Surface Condition:

    Ground NIA NIA N/A N/A NIA NIA NIA NIA N/A N/A (s) 0 port.)

    Results:

    Accept.,,

    ~

    Reject O Info O Comments: Cal Block BWO-PDl-516-02 demonstrated to be ultrasonically equivalent to Flaw Tech Cal Block 22571.

    Baseline Exam.

    ~

    Percent Of Coverage Obtained > 90%:

    No-88%

    Reviewed Previous Data:

    NIA Weld Doc 2A.

    Examiner Level Ill

    ' {J. - ~

    Date Reviewer Signature I

    Dale Crothers, Simon, P.

    8/1312015

    /V //9-A.J//F-I Examiner Level N/A Signature Date Site Review anature I

    Date NIA e.4~~ ii /71,;ke#-nJ L,,,,..oz-

    1. -~~ '

    /O-l-1~-

    Other Level N/A Signature Date ANll Review J__

    Signature Dale NIA G;E" ~~"""

    ~~ll I\\~

    ...... _5_~

    RS-20-012 Attachment 6 fage 41

    ~

    \\ _

    ~-" Exelon UT Calibration,-~amination SiteJUnit:

    BRW 2

    Procedure:

    ER*AA*335-030 Outage No.:

    N/A Summary No.:

    NIA Procedure Rev_:

    4 Report No.:

    UT*2015-oo4 Wor1<scope:

    PSI Work Order No.:

    01782044-01 Page:

    , 2 of 6

    Code:

    ASME 2001 Edition / 2003 Addenda Catlltem:

    NIA Location:

    Steam Tunnel Drawing No.:

    FX*13

    ==

    Description:==

    Flange to Elbow System ID:

    AF


    ~---~~--~-~---~----~-~~-~~--~---~~----

    Component ID: Field Weld 4 Size/Length:

    0.7" / 14.1" Thickness/Diameter:

    0.33r I 4*

    i------

    Limitations:

    Single Sided Access Start Time:

    1032 Finish Time; 1131 Instrument Settings Search Unit Cal.

    Axial Oriented Search Unit Time Date Serial No.:

    0221JM Serial No.:

    SC1489 Checks Calibration Signal Sweep Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech Initial Cal.

    0731 8/13/2015 Reflector Amplitude%

    Divi$10n Sound Path Model:

    USN60SW Linearity:

    2015*L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    105S 8/13/2015 0.5" Notch 80%

    6.0 0.9" Delay:

    4.9803 Range:

    1.5*

    Freq.:

    5.0MHz Center FreQ.:

    NIA Inter. Cal.

    1126 8/13/2015 NIA NIA NIA NIA M'tl Cal/Vel:

    0.1270 Pulser Type:

    Square Inter. Cal.

    NIA NIA NIA NIA NIA Exam Angle:

    so*

    Squint Angle:

    NIA Damping:

    5000hms Reject:

    Final Cal.

    1313 8/13/2015 NIA NIA Nl'A NIA 0%

    Measured Angle:

    so*

    Mode:

    Shear PRF:

    Auto High SU Freq.:

    Couplant NIA NIA NIA NIA 5.0 MHz Exit Point 0.25"

    1. of Elements:

    1 Frequency:

    5.0MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Circumferential Oriented Search Unit Conlig.:

    Single Focus:

    NIA Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    33 Circ. Gain (dB):

    N/A 10 Screen Div. =

    1.5 in. of Sound Path Calibration Block ca1. Block No.

    BWD*PDl-516-02 Thickness o.5" - 2.0" Dia.:

    Flat Cal. Blk. Temp. 84" Temp. Tool:

    29021141 Comp. Temp.

    100* Temp. Tool:

    29021141 Recordable lndication(s):

    Yes~

    NoO Results:

    Accept ~

    Reject O Percent Of Coverage Obtained > 90%:

    No-88o/o Shape:

    Type:

    Ultragel II calibration Signal Sweep Sound Path Round Contour:

    NIA Mfg_:

    So note ch Reflector Amplitude%

    Divi ~iorl Wedge Style:

    MSW QC NIA NIA N(A NIA Exam Batch:

    13C028 Search Unit Cable NIA NIA NIA NIA Type:

    RG*174 6'

    No. Conn.: O Type:

    Ultragel II NIA NIA NIA NIA Length: -

    Mfg.:

    Sonotech NIA N/A NIA NIA Scan Coverage Upstream O Downstream~ Scan dB:

    39 cwo CCW D Scan dB: NIA Exam Surface:

    OD Surface Condition:

    Ground (If Yes. Ref. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data:

    NIA Reference Block Reference/Simulator Biock Serial No.:

    Type:

    Gain Signal s~ Sound Path 142410 cs dB Reflector Amplitude% Oiv!slon 1

    • Angle Beam 28 SDH 80%

    4~3 0.64" NIA NIA N/A NIA N/A N/A N/A N/A NIA N/A Comments: Cal Block BWD*PDl-516-02 demonstrated to be ultrasonically equivalent to Flaw Tech Cal Block 22571.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill

    _¥'_'_ ~

    Date Reviewer Signature I

    Date Crothers, Simon, P.

    8/1312015

    ,lt//;<L

    /Z,//A- ;

    Examiner Level NIA Signature Date Site Review Signature Date NIA

    (!.,,,.,',s JI.

    /'11'-~llCI L v.4f c:L4#/:??PA--

    I

    /C>- 1-/S-Other Level NIA Signature Date ANll Review Signature Date NIA

    ~

    \\'V\\.~~l><'MA+>

    1.... \\,..,.... s:.. 1.

    ~,:)-S- '~

    I RS-20-012 Attachment 6 IPage 42

    \\

    £6., Exelon Site/Unit:

    BRW Summary No.:

    Workscope:

    Code:

    ASME 2001 Edition I 2003 Addenda Drawing No.:

    FX-13 System ID:

    AF 2

    NIA PSI UT Cali bratior11... xamination Procedure:

    ER*AA-335-030 Outage No.: i NIA Procedure Rev.:

    4 Report No.:

    • UT-2015-004 Work Order No.:

    01782044--01 Page: f 3 of 6

    Cat.lltem:

    NIA Location:

    Steam Tunnel

    ==

    Description:==

    Flange to Elbow

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

    ..... ~~~~~~

    Component ID: Field Weld 4 Size/Length:

    0.7. / 14.1" Thickness/Diameter.:

    0.337" /4*

    Limitations:

    Single Sided Access Start Time:

    1032 Finish Time:

    1131 Instrument Settings Search Unit Cal.

    Axial Oriented Search Unit Time Date Serial No.:

    0221JM Serial No.:

    0112WB Checks Calibration Signal S~ep Manufacturer.

    GE Inspection Technologies Manufacturer:

    KB-Aerotech Initial Cal.

    0739 8/13/2015 Reflector Amplitude%

    DiviSion Sound Path Model:

    USN60SW linearity:

    2015-L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    1126 8113/2015 0.5" Notch 80"k 7.6 1.52*

    Delay:

    6.2216 Range:

    2.0*

    Freq.:

    5.0MHz Center Freq.:

    NIA Inter. Cal.

    1131 8/13/2015 NIA NIA N/'A NIA M'tlCaWel:

    0.1270 Pulser Type:

    Square Inter. Cal.

    NIA NIA NIA NJ~

    NIA Exam Angle:

    70° Squint Angle:

    N/A Damping:

    Final Cal.

    1314 8113/2015 NIA NIA NfA NIA 5000hms Reject:

    0%

    Measured Angle:

    71*

    Mode:

    Shear Couplant NIA NIA NIA NIA PRF:

    Auto High SU Freq.:

    5.0 MHz Exit Point 0.3"

    1. of Elements:

    1 Frequency:

    5.0MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Circumferential Oriented SeJ1rch Unit Config.:

    Single Focus:

    NIA Voltage:

    450 Pulse Width:

    100 Type:

    Ultragel II Calibration Signal S~ep Sound Path Shape:

    Round Contour:

    NIA Mfg.:

    Sonotech Reflector Amplitude%

    Divi$ion Wedge Style:

    MSWQC NIA NIA NfA NIA Ax. Gain (dB):

    42 Circ. Gain (dB):

    NIA Search Unit Cable Exam Batch:

    13C028 NIA NIA NfA NIA 10 Screen Div.-=

    2 in. of Sound Path Type:

    RG-174 Length: 6' No. Conn.: O Type:

    Ultragel II NIA NIA NIA NIA Mfg.:

    Sonotech Calibration Block Scan Coverage NIA NIA NIA NIA Gal. Block No.

    BWO-PDl-516-02 Upstream O Downstream~ Scan dB:

    42 Reference Block Reference/Simulator Block Thickness o.5" - 2.0*

    Dia.:

    Flat Gain Signal Sv.leep Sound Palh cwo CCWO Scan dB: NIA Serial No.:

    142410CS dB Reflector Amplitude% Divls;on Cal. Blk. Temp. 84° Temp. Tool:

    29021141 1

    • Angle Beam s'.o Exam Surface:

    OD Type:

    41 SDH 80%

    1.0*

    Comp. Temp.

    ~

    Temp. Tool:

    29021141 Surface Condition:

    Ground NIA NIA NIA NfA NIA Recordable lndication(s):

    Yes O No~

    (If Yes, Ref. Attached Ultrasonic Indication Report.)

    N/A NIA N/A NIA NIA Results:

    Accept ~

    Reject O Info O Comments: Cal Block BWO-PDl-516-02 demonstrateit to be ultrasonically equivalent to Raw Tech C~I Block 22571.

    Percent Of Coverage Obtained > 90"/o:

    No-88%

    Reviewed Previous Data*

    Examiner Level Ill Crothers, Simon, P.

    Examiner Level NIA NIA Other NIA Level NIA RS-20-012 Attachment 6

    ~f-~ - ~

    Signature Signature NIA Date I Reviewer 811312015

    /[/ // Date I Site Review 4if#,'.s //./?1'4"~"'1/ L..,&

    Date I ANll Review

    "-~ ~-,~

    ~"'"'->

    Baseline Exam. Weld Doc 2A.

    Signature

    ' I Date

    ,A./)(~

    I

    ./) Signature c-K-*~~

    L Signature

    \\A.

    ~.

    Date

    /0--1-;S-Date

    \\0-S"-~

    1Page 43

    ~*Exelon.

    Supplemental Report

    .imary No.: NIA Sketch or Photo:

    Work Package: 01782044-01 Weld: FW-4 Sketch 1: Coverage Plot Weld Crown Width: 0.7" Counterbore US: None Counterbore OS: None Profile@ LO (Extrados)

    Scanned across weld with 45° probe, coverage credit on far side of weld taken with higher angles.

    0 I

    Flow Report No.:

    UT-2015-004

    /

    Page:

    4 of 6 '

    1" 2"

    3" I

    I I

    Note: 70° used to obtain remaining coverage, scan limited to area shown.

    Coverage Cale:

    Axial Coverage = 100%

    e ~.

    Circ Coverage= 1.3" of 1.7" exam box width= 76.5%

    /"'] ") ~ "" ~-e"-/l/

    Total= (100% + 76.5%)/2 = 88%

    ~-,¥/??~

    ---L E'xt:i.P --*....... * * -.. ~ - - - -* **-* * - :

    ~

    'V 1..-.?ll.

    / t:')-

    / - / s ANI I ANll Rl;VIEW

    ~,

    REVIEW DATE J'...kk:\\ ~~

    RS-20-012 Attachment 6 Page 44

    ~*Exelon.

    Supplemental Report

    ... ~.nmary No.: NIA Sketch or Photo:

    Work Package: 01782044-01 Weld: FW-4 Sketch 2: Indication Plot Profile @ 1" CW Flange Profile@ LO (Extrados)

    Flange Profile @ 2" CW Flange Flow

    .43" 0.39" 0.46" Report No.:

    UT-2015.004 Page:

    5 Of 6 (

    Elbow I

    ~

    Root Geometry, seen intermittently 360°

    ~Geometric reflector from ID mismatch, seen intermittently 360°.

    f.,*.~H-ttt~111,J Flange was open at the time of inspection, inspector verified this a RS-20-012 Attachment 6 condition visually.

    c,.£#/hu,..._ 5

    /5X'tUJ/ll "4VfiZ /Q- /-I 1"

    2" I

    I 3"

    I ANI I ANll REVIE~ ~\\ \\\\

    REVIEW DATEL~ti- -!--**

    • Page 45

    .::'Exelon.

    Ultrasonic Indication Report Site/Unit:

    BRW I

    2 Procedure:

    ER*AA-335-030 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    4 Report No.:

    UT*2015-Q04 Workscope:

    PSI Work Order No.:

    01782044-01 Page:

    6 of 6

    Wa W,_

    Search Unit Angle: --------

    Wo Location:

    Centerline Lo Location:

    Extrados 45° /60 0

    @ Piping Welds O Ferritic Vessels

    ~ 2"T Q Other NIA c'

    .L i

    Wl W2 cSU: I MP Metal Path w

    Dist From Wo To S.U. At Maximum R I

    esponse I

    -+-~DATUM

    =orward)

    -rrr Lo I

    3ackward) h 'b 0 J, J Comments:

    Field Weld4 Wl =~

    w.i

    ' i Indication O/o w

    Forward Backward L1 L

    L2 RBR Remarks Angle No.

    Of Max NIA Of Max NIA Of Max N/A Max NIA Amp.

    Of Of I

    DAC w

    MP Wt MP W2 MP Max Max I

    45*

    1 60°/o 0.4*

    o.e*

    NIA NIA NIA NIA NIA 1.0*

    NIA NIA Root Geometry from OS side.

    45° 2

    60'%

    o.s*

    o.e*

    NIA NIA NIA NIA NIA 2.0*

    NIA NIA ID Geometry, see Indication Plot.

    eo*

    3 80"4 0.1*

    o.ss*

    NIA NIA NIA NIA NIA o*

    NIA NIA Root Geometry from OS side.

    I eo*

    4 60%

    0.85" o.sa*

    NIA NIA NIA NIA NIA 2.0*

    NIA NIA ID Geometry, see Indication Plot.

    i I

    Examiner Level m

    ()_ -~

    Date Reviewer Signature I

    Date Crothers, Simon, P.

    8/13/2015

    ~/#-

    ~/?-

    Examiner Level NIA Signature Date Site Review j!)~ture Date I

    NIA

    _MHl'v. 5:, l~y'

    _.;_~ --

    VAtt/J*"

    Other Level NIA Signature Date ANll Review cl L-.......:r9.. nature

    ' Cate NIA

    ~IS'O V'A.~~A-...1

    ~..::;>-::;;... \\~

    RS-20-012 Attachment 6 I

    1Page 46

    2CV-21-56

    ~

    £§:7 Exeu.on.

    UT Calibration/E:.M~mination Site/Unit:

    BRW I

    2 Procedure:

    ER-AA-33S-031 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    6 Report No.:

    UT-201S-012 Worl<scope:

    PSI Work Order No.:

    01782743-01 Page:

    1 of 6

    Code:

    ASME 2001 Edition/ 2003 Addenda CatJltem:

    NIA Location:

    CV Pump Room Drawing No.:

    FX-17

    ==

    Description:==

    Pipe to Tee System ID:

    CV --------------------------------------------------------------------------

    Component ID: Field Weld 2 Size/Length:

    4* 114_5*

    Thickness/Diameter:

    0.531

    • I 4*

    Limitations:

    Tee Radius Start Time:

    2339 Finish Time:

    0045 Instrument Settings Search Unit Cal.

    Time Date Axial Oriented Search Unit Serial No.:

    0221JM Serial No.:

    SB0442 Checks Calibration Signal Sweep Sound Path GEIT Initial Cal.

    1950 10/13/2015 Reflector Amplitude%

    Division Manufacturer:

    GE Inspection Technologies Manufacturer:

    Inter. Cal.

    2339 10/13/2015 1* Notch 80%

    9.4 1.41*

    Model:

    USN60SW Linearity:

    2015-L-OOO Size:

    0.25" Model:

    Comp-G Inter. Cal.

    2350 10/13/2015 NIA NIA NIA NIA Delay:

    4.1716 Range:

    1.s*

    Freq.:

    2.25 MHz Center Freq.:

    NIA Inter. Cal.

    NIA NIA NIA NIA NIA M'tlC2Wel:

    0.1230 Pulser Type:

    Square Exam Angle:

    45° Squint Angle:

    NIA Final Cal.

    0133 10/1412015 NIA NIA NIA NIA Damping:

    5000hms Reject:

    0%

    Measured Angle: ~

    Mode:

    Shear

    ~

    NIA NIA NIA N/A Coup I ant PRF:

    Auto High SU Freq.:

    2.25MHz Exit Point 0.2*

    1. of Elements: -

    1-Cal. Batch:

    15E082 Circumferential Oriented Search Unit Frequency:

    2.25MHz Rectify:

    Fullwave Config.:

    Single Focus:

    NIA Type:

    Ultragel II Calibration Signal Sweep Sound Path Reflector Amplitude%

    Division Voltage:

    450 Pulse Width:

    220 Shape:

    Round Contour:

    NIA Mfg.:

    Sonotech MSW QC NIA N/A NIA NIA Wedge Style:

    Exam Batch:

    15E082 NIA NIA NIA NIA Ax. Gain (dB):

    20 Circ. Gain (dB):

    NIA Search Unit Cable Type:

    Ultragel II NIA NIA NIA NIA 1.5 Sound Path Type:

    RG-174 length: 6' No. Conn.: O Ml.

    Sonotech NIA NIA NIA 10 Screen Div. =

    in. of g..

    NIA Scan Coverage Calibration Block Reference Block Reference/Simulator Block Cal. Block No.

    22572 Upstream~ Downstream~ Scan dB: ~

    Gain Signal Sweep Sound Path cw~

    CCW ~ Scan dB:

    38 Serial No.:

    43842 SS dB Reflector AmpUtude% Division Thickness o.5* to 2.0" Dia.:

    Flat Cal. Blk. Temp. 72° Temp. Tool:

    29021145 Exam Surface:

    OD

    -- Type:

    1

    • Angle Beam 20 SOH 25%

    6.9 1.04*

    Comp. Temp.

    75* Temp. Tool:

    29021145 Surface Condition:

    Ground NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA 0

    ~

    ,port.)

    Comments: Baseline Exam. Post RT.

    Results:

    Accept~

    Reject D Info O Weld Doc2A Percent Of Coverage Obtained > 90%:

    No-83.3%

    Reviewed Previous Data:

    Examiner level II Salley, Michael Examiner Level NIA NIA Other Level NIA Signature NIA RS-20-012 Attachment 6 No Date I Reviewer 1011412015 C/MON CMTHEllS Date Date s~

    Signature

    -:iii Signature Date 1011 sf IS" Date

    /O*l~*l~

    Date

    /U*lr*~I~

    Page 47

    ~

    ~Exelon, UT Calibration/E"'dmination Site/Unit:

    BRW I

    2 Procedure:

    ER*AA-335.Q31 Outage No.:

    NIA Summary No.:

    N/A Procedure Rev.:

    6 Report No.:

    UT*201M12 Workscope:

    PSI Work Order No.:

    01782743.()1 Page:

    2 of 6

    Code:

    ASME 2001 Edition/ 2003 Addenda Cat./ltem:

    NIA Location:

    CV Pump Room Drawing No.:

    FX-17

    ==

    Description:==

    Pipe to Tee

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~--

    System ID:

    CV


    _..'.""'.""'.'--=-:----:--:~~

    Component ID: Field Weld 2 Size/Length:

    4" / 14.5" Thickness/Diameter:

    0.531 * / 4*

    Limitations:

    Tee Radius Start Time:

    2339 Finish Time:

    0045 Instrument Settings Search Unit Cal.

    Axial Oriented Search Unit Time Date Serial No.:

    0221JM Serial No.:

    SB0625 Checks Calibration Signal Sweep Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech Initial Cal.

    1951 10/13/2015 Reflector Amplitude%

    Division Sound Path Model:

    USN60 SW Linearity:

    2015-L-003 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    0004 10/14/2015 1.0* Notch 80*4 8.8 1.76*

    Delay:

    5.3369 Range:

    2.0u Freq.:

    2.25 MHz Center Freq.:

    NIA Inter. Cal.

    0016 10/14/2015 NIA NIA NIA NIA M'tlCalNel:

    0.1230 Pulser Type:

    Square Exam Angle:

    Inter. Cal.

    NIA NIA NIA NIA NIA 60" Squint Angle:

    NIA Damping:

    5000hms Reject:

    Final Cal.

    0140 10/1412015 NIA N/A NIA NIA O'Yo Measured Angle:

    59*

    Mode:

    Shear PRF:

    SU Freq.:

    Couplant NIA N/A NIA NIA Auto High 2.25MHz Exit Point 0.25"

    1. of Elements:

    1 Frequency:

    2.25 MHz Rectify:

    Fullwave NIA Cal. Batch:

    15E082 Circumferential Oriented Search Unit Config.:

    Single Focus:

    Voltage:

    450 Pulse Width:

    220 Shape:

    Contour:

    Type:

    Ultragel II Calibration Signal Sweep Sound Path Round NIA Mfg.:

    Sonotech Reflector Amplitude%

    Division Wedge Style:

    MSW QC NIA NIA NIA NIA Ax. Gain (dB):

    40 Circ. Gain (dB):

    NIA Search Unit Cable Exam Batch:

    15E082 NIA NIA NIA NIA 10 Screen Div. =

    2 in. of Sound Path Type:

    RG-174 Length: 6' No. Conn.: O Type:

    Ultragel II NIA NIA NIA NIA Mfg.:

    Sonotech Calibration Block Scan Coverage NIA N/A NIA NIA Cal. Block No.

    22572 Upstream 0 Downstream 0 Scan dB:

    46 Reference Block Reference/Simulator Block Thickness o.5" to 2.0*

    Dia.:

    Flat Gain Signal Sweep Sound Path cwo CCW 0 Scan dB: NIA Serial No.:

    43842SS dB Reflector Amplitude% Division Cal. Blk. Temp. 72° Temp. Tool:

    29021145 Exam Surface:

    OD Type:

    1

    • Angle Beam 40 SDH 50"/o 7.2 1... s*

    Comp. Temp.

    75* Temp. Tool:

    29021145 Surface Condition:

    Ground NIA NIA NIA NIA NIA Recordable lndication(s):

    Yes O No~

    (If Yes, Ref. Attached Ultrasonic Indication Report.)

    NIA NIA NIA NIA NIA Results:

    Accept~

    Reject O Info D Comments: Baseline Exam. Post RT.

    Weld Doc2A Percent Of Coverage Obtained > 90"/o:

    No -83.3"/o Reviewed Previous Data:

    No Examiner Level II Salley, Michael Date I Reviewer 10/14/2015 T#Elt5 L-111 Date 10/f S /,s Examiner Level NIA Date I Site Review Date NIA

    • IS'*&$""

    Other Level NIA Signature Date Date NIA

    /o*,:S* ""'s RS-20-012 Attachment 6 Page 48

    ~

    &5i7 Exelon.

    UT CalibrationlEAdmination Site/Unit:

    BRW I

    2 Procedure:

    ER*AA*33S-031 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    6 Report No.:

    UT*201S-012 Wort<scope:

    PSI Wort< Order No.:

    01782743-01 Page:

    3 of 6

    Code:

    ASME 2001 Edition/ 2003 Addenda Cat.lltem:

    NIA Location:

    CV Pump Room Drawing No.:

    FX*17

    ==

    Description:==

    Pipe to Tee System ID:

    CV -----------------------------------------------------------

    Com po n en t 10: Field Weld 2 Size/Length:

    4* 114.5*

    Thickness/Diameter:

    0.531* 14*

    Umilations:

    Tee Radius Slart Time:

    2339 Finish Time:

    0045 Instrument Settings Search Unit Cal.

    Axial Oriented Searcl'I Unit Time Date Serial No.:

    0221JM Serial No.:

    SB0419 Checks Initial Cal.

    Calibration Signal Sweep Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    GEIT 1952 10/13/2015 Reflector Amplitude%

    Division Model:

    USN60SW Linearity:

    2015-L-003 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    0026 10/1412015 1.o* Notcl'I 80%

    9.7 z.92*

    Delay:

    6.2422 Range:

    3.o*

    Freq.:

    2.25MHz Center Freq.:

    NIA Inter. Cal.

    0031 10/1412015 NIA NIA NIA NIA M'tl CalNel:

    0.1230 Pulser Type:

    Square Inter. Cal.

    N/A NIA NIA NIA NIA Exam Angle:

    70° Squint Angle:

    NIA Damping:

    5000hms Reject:

    Final Cal.

    0145 10/1412015 NIA NIA NIA NIA 0%

    Measured Angle:

    70° Mode:

    Shear PRF:

    Auto High SU Freq.:

    2.25 MHz Exit Point

    1. of Elements:

    Couplant NIA NIA NIA NIA 0.3*

    1 Frequency:

    2.25 MHz Rectify:

    Fullwave NIA Cal. Batch:

    15E082 Circumferential Oriented Search Unit Conlig.:

    Single Focus:

    Vollage:

    450 Pulse Width:

    220 Shape:

    Contour:

    NIA Type:

    Ultragel II Calibration Signal Sweep Sound Path Round Mfg.:

    Sonotech Reflector Amplitude%

    Division Wedge Style:

    MSW QC NIA NIA NIA NIA Ax. Gain (dB):

    49 Circ. Gain (dB):

    NIA Search Unit Cable Exam Batch:

    15E082 NIA NIA NIA NIA 10 Screen Div.=

    3 in. of Sound Path Type:

    RG-174 Length: 6' No. Conn.: o Type:

    Ultragel II NIA NIA NIA NIA Mfg.:

    Sonotech Calibration Block Scan Coverage NIA NIA NIA NIA Cal. Block No.

    22572 Upstream ~ Downstream~ Scan dB:

    49 Reference Block Reference/Simulator Block Thickness 0.5" to 2.0*

    Dia.:

    Flat Gain Signal Sweep Sound Path cwo CCW O Scan dB: NIA Serial No.:

    43842 SS dB Reflector Amplitude% Division Cal. Blk. Temp. 72° Temp. Tool:

    29021145

    -- Type:

    Exam Surface:

    OD 1" Angle Beam 43 SDH 80%

    3.2 0.95" Comp. Temp.

    75* Temp. Tool:

    29021145 Surface Condition:

    Ground NIA NIA NIA NIA NIA Recordable lndication(s):

    Yes O No~

    (If Yes, Ref. Attached Ultrasonic Indication Report.)

    NIA NIA NIA NIA NIA Results:

    Accept~

    Reject O Info O Comments: Baseline Exam. Post RT.

    Percent Of Coverage Obtained > 90"/o:

    Examiner Level 11 Salley, Michael Examiner NIA Other NIA Level NIA Level NIA RS-20-012 Attachment 6 No* 83.3%

    Reviewed Previous ~Data:

    Signature No Date I Reviewer 1011412015 c1MoA.1 CA..oTHE ll.$

    Date I Site Review Date Ad,..., I"'/. Pt-~

    Weld Doc2A

    , Date trJ/fS/ I.>

    Date 10*1~-\\'S'"

    Date

    /u*,,s.~,~

    Page 49

    ~

    §:;J fExeton, UT Calibration/.mination Site!Unit:

    BRW I

    2 Procedure:

    ER-AA-335-031 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    6 Report No.:

    UT-2015-012 Workscope:

    PSI Work Order No.:

    01782743--01 Page:

    4 of 6

    Code:

    ASME 2001 Edition / 2003 Addenda CatJltem:

    NIA Location:

    CV Pump Room Drawing No.:

    FX-17

    ==

    Description:==

    Pipe to Tee

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

    System ID:

    CV


    ::-~------..-----:~

    Component ID: Field Weld 2 Size/Length:

    4* / 14.5" Thickness!Diameter:

    0.531

    • 14" Limitations:

    Tee Radius Start Time:

    2339 Finish Time:

    0045 Instrument Settings Search Unit Cal.

    Axial Oriented Search Unit Time Date Serial No.:

    0221JM Serial No.:

    15-66 Checks calibration Signal Sweep Manufacturer:

    GE Inspection Technologies Manufacturer:

    RTD Initial Cal.

    1955 10/13/2015 Reflector Amplitude%

    Division Sound Path Model:

    USN 60 SW Linearity:

    2015-L-003 Size:

    2(7x10)mm Model:

    TRL2-Aust Inter. Cal.

    0041 10/1412015 1.0" Notch 80%

    10.0 2.0*

    Delay:

    6.8100 Range:

    2.0*

    Freq.:

    2.0MHz Center Freq.:

    NIA Inter. cal.

    0045 10/1412015 NIA NIA NIA NIA M'tlCaWel:

    0.2280 Pulser Type:

    Square Inter. cal.

    NIA NIA NIA NIA NIA Exam Angle:

    60" Squint Angle:

    2*

    Damping:

    5000hms Reject:

    Final Cal.

    0151 10/1412015 NIA NIA NIA NIA 0%

    Measured Angle:

    so*

    Mode:

    Long PRF:

    SU Freq.:

    Couplant NIA NIA NIA NIA Auto High 2.0 MHz Exit Point 0.35"

    1. of Elements:

    2 Frequency:

    2.0 MHz Rectify:

    Fullwave

    -- Cal. Batch:

    15E082 Circumferential Oriented Search Unit Config.:

    D-SBS Focus:

    25mmSP Voltage:

    450 Pulse Width:

    250 Shape:

    Type:

    Ultragel II Calibration Signal Sweep Sound Path Rect.

    Contour:

    Flat Mfg.:

    Sonotech Reflector Amplitude 0k Division Wedge Style:

    Integral NIA NIA NIA NIA Ax. Gain (dB):

    60 Circ. Gain (dB):

    NIA Search Unit Cable Exam Batch:

    15E082 NIA NIA NIA NIA 10 Screen Div.=

    2 in. of Sound Path Type:

    RG-174 Length: 6' No. Conn.: O Type:

    Ultragel II NIA NIA NIA NIA Mfg.:

    Sonotech Calibration Block Scan Coverage NIA NIA NIA NIA Cal. Block No.

    22572 Upstream ~ Downstream O Scan dB:

    60 Reference Block Reference/Simulator Block Thickness o.5* to 2.0" Dia.:

    Flat Gain Signal Sweep Sound Path cwo CCW O Scan dB: NIA Serial No.:

    43842 SS dB Reflector Amplitude% Division cat Blk. Temp. ~

    Temp. Tool:

    29021145

    -- Type:

    Exam Surface:

    OD 1

    • Angle Beam 54 SDH 80%

    7.5 1.49*

    Comp. Temp.

    75° Temp. Tool:

    29021145 Surface Condition:

    Ground NIA NIA NIA NIA NIA Recordable lndication(s):

    Yes O No~

    (If Yes, Ref. Attached Ultrasonic Indication Report.)

    NIA NIA NIA NIA NIA Results:

    Accept ~

    Reject O Info O Comments: Baseline Exam. Post RT.

    Percent Of Coverage Obtained > 90%:

    No-83.3%

    Reviewed Previous Data:

    Examiner Level II Salley, Michael Examiner Level NIA NIA Other Level NIA Signature NIA RS-20-012 Attachment 6 Weld Doc2A No Date I Reviewer 101141201s Sl~/tJ CIUJT"HEll.S L-111 Date I Site Review

    \\

    Datel ANll

    • p,._:..

    .I I Date tfJ/I Sf IS Date 10*1~... ~

    Date

    /0- I'S*.1,vl ~

    Page 50

    ~Exelon.

    Supplemental Report Report No.:

    UT-2015-012 Page:

    5 of 6

    Summary No.: NIA

    ~---------

    Examiner: Salley, Michael

    /J")T'.5 Level:

    II Reviewer:~~~~::?!:!:..:!~~-

    Examiner: NIA level:

    NIA Site Review:

    ~--------

    ...... ~!UW~~p..D:~:::::=.~

    Other: NIA Level:

    NIA ANll Review: 8/&b.l~~~~~::1.lii:D.~

    CommerWork Order: 01782743-01 Weld: FW-2

    • Sketch 1: Coverage Plot Weld Crown Width: 0.9" Sketch or Photo:

    Weld Length: 14.5" Counterbore OS:

    None Counterbore US:

    None Limitation:

    Tee radius obstructed OS exams for 4.25"@ 180°.

    Flow 0.65" Profile @ 0° (TDC)

    US Coverage represents 14.5" of 14.5" weld length.

    OS Coverage represents 10.25" of 14.5" weld length.

    0 1"

    2" 3"

    I I

    I I

    RS-20-012 Attachment 6 Lo FW-2 i Date: 10/ts/15 Date: 10.,,._,~

    Date: ~* 'S* ~' c Page 51

    liii? Exelon.

    Supplemental Report Report No.:

    UT -2015-012 Page:

    6 of 6

    Reviewer:L c..,..d..

    Date: 10/ts/15 Site Review: ::r.,'\\ \\M~\\\\er *-\\::='\\ a jll" Date:

    10*1$'*\\S" Summary No.: NIA

    ~~~~~~~~~~

    Examiner: Salley, Michael MT J Level:

    II Examiner: NIA Level:

    NIA

    ~~~~~~~~-

    0th er: NIA Level:

    NIA ANll Review:.4/,,,,m. /l,,,w. ~~

    Date: /N~*~'f We*Br.der: 017827 43-01 Weld: FW-2 Sketch 2: Coverage Plot Sketch or Photo:

    0 I

    Flow 1"

    2" I

    I Note: 70° used to obtain remaining coverage, scan limited to area shown.

    Single sided access for 4.25" @ 180° Pipe 60° RL Tee 3"

    I Far side of weld examined as per single sided access rules - No coverage credit taken.

    Coverage Cale Exam Length Result Ax Upst 14.5" of 14.5" 100%

    Ax Dnst 10.25" of 14.5" 70.7%

    Circ Upst 14.5" of 14.5" 100%

    Circ Dnst 10.2511 of 14.5" 70.7%

    Total:

    341.4%

    Total/ 4:

    83.3%

    RS-20-012 Attachment 6 Page 52

    2CV-21-57 g;-,-, Exelon UT Calibratiotl,-.<amination SC 10/1z./1S Site/Unit:

    BRW I

    2 Procedure:

    ER*AA-335--03/ t Outage No.:

    ~

    NIA Summary No.:

    NIA Procedure Rev.:

    / 6 SC. tfl/ll./ 15 Report No.: : UT*201S-010 Workscope:

    PSI Work Order No.:

    01692238-08 Page:

    ..:__ of 8

    Code:

    ASME 2001 Edition/ 2003 Addenda CatJllem:

    NIA Location:

    CV Pump Room Drawing No.:

    FX*17

    ==

    Description:==

    Tee to Pipe Sys~mlD:

    ~c~v:.._ _______________________________

    --:-~:----:-----:-:-:-:-:-::::-----:::-:-:--__,:=:--7".":'--:-:::::--:-::---

    Component ID: Field Weld 2 Size/Length:

    1.o* 114.5" Thickness/Diametei::

    0.531* 14*

    Limitations:

    Serial No.:

    Manufacturer:

    Tee Radius Instrument Settings 0221JM GE Inspection Technologies Model:

    USN 60 SW Linearity:

    2015-L-001 Delay:

    4.1716 Range:

    1.5*

    M'tl CalNel:

    0.1230 Pulser Type:

    Square Damping:

    SOOOhms Reject:

    0%

    PRF:

    Auto High SU Freq.:

    2.25 MHz Frequency:

    2.25MHz Rectify:

    Fullwave Voltage:

    450 Pulse Width:

    220 Ax. Gain (dB):

    20 Circ. Gain (dB):

    NIA 10 Screen Div.=

    1.5 in. of Sound Path Calibration Block Start Time:

    0948 FinishT~:

    1019 Search Unit Serial No.:

    SB0442 Manufacturer:

    GEIT Size:

    0.25*

    Model:

    Comp-G Freq.: 2.25 MHz Exam Angle: ~

    Measured Angle:

    Center Freq.: ~

    Squint Angle:

    ~

    45*

    Mode:

    Shear Cat.

    Checks I Time I Date Initial Cal.

    0722 8/1412015 Inter. Cal.

    0948 8/14/2015 Inter. Cal.

    1002 8/1412015 Inter. Cal.

    NIA Final Cal.

    1137 I 811412015 Couplant Exit Point 0.2"

    1. of Elements: _ 1_

    Cal. Batch:

    13C028 Config.:

    Single Focus:

    NIA Type:

    Ultragel II Shape:

    Round Contour:

    NIA Mfg.:

    Sonotech Wedge Style:

    MSW QC Exam Batch:

    13C028 Search Unit Cable Type:

    RG-174 Length: ~

    No. Conn.: 0 Type:

    Ultragel II Mfg.:

    Sonotech Axial Oriented Search !Jnlt Calibration Signal S~ep Sound Palh Reflector Amplitude%

    Dlvi~n 1" Notch 80%

    9.il 1.4r NIA NIA NiA NIA NIA N/A NiA NIA NIA NIA Ni~

    NIA NIA NIA NIA NIA Circumferential Oriented Search Unit Calibration Signal Sweep SoundPa1h Reflector Amplitude%

    Divi$ion NIA NIA N/'A NIA NIA N/A NIA NIA NIA N/A NIA NIA NIA N/A NfA NIA Cal. Block No.

    BWD-PDl-304-01 Upstream~

    Scan Coverage Downstream~ Scan dB: ~

    CCW ~ Scan dB:

    32 Reference Block Gain Reference/Simulator Bjoc:k Signal

    ~:

    Thickness 0.5"

    • 2.0" Dia.:

    Flat cw~

    Serial No.:

    171311 SS dB Reflector Amplitude% Di Sound Palh Cal. Blk. Temp. 86° Temp. Tool:

    29021141 Exam Surface:

    OD Type:

    1

    • Angle Beam 20 SDH 25%

    6~9 1.04*

    Comp. Temp.

    108° Temp. Tool:

    29021141 Surface Condition:

    Ground NIA NIA NIA tfJA NIA Recordable lndication(s):

    Yes O No~

    (II Yes, Ref. Attached Ultrasonic Indication Report.)

    NIA NIA N/A NIA NIA Results:

    Accept.,,

    Reject O Info O Percent Of Coverage Obtained > 90%:

    No-83.3".4 Reviewed Previous Data:

    NIA Examiner Level Ill 'y

    • A cJE; Date Crothers, Simon, P.

    8/14/2015 Examiner Level N/A Signature Date NIA

    • Other Level NIA Signature Date N/A RS-20-012 Attachment 6 Reviewer Site Review Comments: Cal Block BWD-PDl-304-01 demonstratedito be ultrasonically equivalent to Flaw Tech Ca.I Block 22572.

    Baseline Exam.

    Weld Doc2B.

    Signature I

    Dale

    ,/!//~

    ,!'J//4-Signature Date

    c. ~...... s ;/. /?IC'~,,,.,,/

    Lv.02 ~.,y~~

    /tJ-/*/.f" ANll Review J_~

    Date

    ~M~~A--...J

    i.O \\-,..\\ l<

    Page 53

    ~Exelon Site/Unit:

    BRW 2

    Summary No.:

    NIA W()l1(scope:

    PSI Code:

    ASME 2001 Edition / 2003 Addenda Drawing No.:

    FX-17 System ID:

    CV UT Calibration. -xamination Procedure:

    Procedure Rev.:

    Work Order No.:

    Cat.lltem:

    NIA

    ~C. to/IJ./15 ER*AA*335-03sf l I' b Sc..

    10/12./IS 0169223&-08 Outage No.:

    I N/A Report No.: :

    UT-201~10 Page:

    1 2 of s

    Location:

    CV Pump Room

    ==

    Description:==

    ~T~e~e~to.;._P_ip~e-----------------------------------------------------;--------------

    Component ID: Field Weld 2 Size/length:

    1.o* 114.5*

    Thickness/Diameter:

    0.531* 14*

    Limitations:

    Tee Radius Start Time:

    0948 Finish Time:

    1019 Instrument Settings Search Unit Cal.

    I Time Date Axial Oriented Search 1Unit Serial No.:

    0221JM Serial No.:

    SB0625 Checks Calibration Signal Sw~ep Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech Initial Cal.

    0729 8/14/2015 Reflector Amplitude%

    Division Sound Path Model:

    USN60SW linearity:

    2015-L-001 Size:

    o.2s*

    Model:

    Comp-G inter. Cal.

    1002 8/14/2015 1* Notch SO%

    sis 1.1&*

    Delay:

    4.9441 Range:

    2.0*

    Freq.:

    2.25MHz Center Freq.:

    NIA Inter. Cal.

    1009 8/14/2015 NIA NIA Ni,A NIA M'tlCaWel:

    0.1230 Pulser Type:

    Square Inter. Cal.

    NIA NIA NIA

    ~A NIA Exam Angle:

    &0*

    Squint Angle:

    NIA Damping:

    5000hms Reject:

    Final Cal.

    1138 8114/2015 NIA NIA Ni,A NIA 0%

    Measured Angle:

    59° Mode:

    Shear NiA PRF:

    SU Freq.:

    Couplant NIA NIA N/A Auto High 2.25 MHz Exit Point o.2s*

    1. of Elements:

    1 Frequency:

    2.25 MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Circumferential Oriented Search Unit Config.:

    Single Focus:

    N/A Voltage:

    450 Pulse Width:

    220 Ax. Gain (dB):

    39 Circ. Gain (dB):

    NIA 10 Screen Div. =

    2 in. of Sound Path Calibration Block Cal. Block No.

    BWD-PDl-304-01 Thickness o.s* -2.0*

    Dia.:

    Flat Cal. Blk. Temp. as* Temp. Tool:

    29021141 Comp. Temp.

    10s* Temp. Tool:

    29021141 Recordable lndication(s):

    Yes~

    NoO Results:

    Accept "

    Reject O Percent Of Coverage Obtained > 90%:

    No-83.3%

    Shape:

    Contour:

    Type:

    Ultragel II Calibration Signal Sw.,ep Sound Path Round NIA Mfg.:

    Sonotech Reflector Amplitude%

    DiviSion I

    Wedge Style:

    MSW QC NIA NIA WA NIA Search Unit Cable Exam Batch:

    13C028 NIA NIA NJ.A NIA RG*174 6'

    No. Conn.: 0 Type:

    Ultragel II NIA NIA WA NIA Type:

    Length: -

    Mfg.:

    Sonotech WA NIA N/A NIA Scan Coverage Upstream~ Downstream~ Scan dB:

    45 cwo CCWQ Scan dB: NIA Exam Surface:

    OD Surface Condition:

    Ground (If Yes. Ref. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data*

    NIA

    ~ -

    I Reference Block Reference/Simulator BJock Serial No.:

    Type:

    Gain Signal S~eep Sound Path 171311 SS dB Reflector Amplitude% DiY}sion 1

    • Angle Beam 39 SCH 50%

    t~2 1.4s*

    I NIA NIA N/A NIA NIA I

    NIA N/A N/A NIA N/A Comments: Cal Block BWD*PDl-304-01 demonstrate~ to be ultrasonically equivalent to Flaw Tech C~I Block 22572.

    Baseline Exam. Weld Doc 28.

    Examiner Level Ill.. fl

    ~

    Dale Reviewer Signature I

    Date

    /V/nj Crothers, Simon, P.

    n.

    8/1412015 A.JI~

    Examiner Level NIA Signature Dale Site Review dgnature ~

    Date 0NIA

    ~ J.,./J 11. pu.. q.o,,v J.v.DT 5¥~.!..

    /0-/-~.>

    Other Level NIA Signature Date ANll Review Signature I

    Date NI.~

    L~ ~~A--1 J_ """d**

    ~o \\'1.-\\ \\-<

    RS-20-012 Attachment 6 Page 54

    ,,fi!j§;/ Exelon UT Calibration,-xamination SC 10/12/1s Site/Uni I:

    BRW 2

    Procedure:

    ER-AA-335--03,lf I Outage No.:

    NIA

    ~-----------------------------~

    /'b s c.

    10/1z. /1s Repof'I No.: ; UT-2015-010 Summary No.:

    NIA Procedure Rev.:

    Workscope:

    PSI Work Order No.:

    0169223&-08 Page:~ ol 8

    Code:

    ASME 2001 Edition I 2003 Addenda CatJllem:

    NIA Location:

    CV Pump Room Drawing No.:

    FX-17

    ==

    Description:==

    ..:T..:ee_:__t_o_P_i.:_p_e _______________________________________________ __. _________ _

    System ID:

    CV


    ..;------------~

    Component ID: Field Weld 2 Size/Length:

    1.0" / 14.5" Thickness/Diametet:

    0.531" / 4" I

    Limitations:

    Tee Radius Start Time:

    0948 Finish Tim':

    1019 Instrument Settings Search Unit Cal.

    Axial Oriented Search ~nit Time Date Serial No.:

    0221JM Serial No.:

    SB0419 Checks Sweep Initial Cal.

    Calibration Signal Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    GEIT 0735 811412015 Reflector Amplitude%

    Divi!;iorl Model:

    USN60SW Linearity:

    2015-L-001 Size:

    0.25" Model:

    Comp-G Inter. Gal.

    1009 8/1412015 1* Notch 80%

    9~

    2.92" Delay:

    5.8547 Range:

    3.0" Freq.:

    2.25 MHz Center Freq.:

    NIA Inter. Cal.

    1015 8/14/2015 NIA NIA Ni,A NIA M'tlCalNel:

    0.1230 Pulser Type:

    Square Exam Angle:

    Squint Angle:

    Inter. Gal.

    N/A NIA NIA

    ~A NIA 10*

    NIA Damping:

    5000hms Reject:

    Final Cal.

    1139 8/14/2015 NIA NIA Ni,A NIA 0%

    Measured Angle:

    10*

    Mode:

    Shear PRF:

    Auto High SU Freq.:

    2.25MHz Exit Point 0.3"

    1. of Elements:

    Couplant NIA 1

    NIA NiA NIA Frequency:

    2.25MHz Rectify:

    Fullwave Config.:

    Single Focus:

    Cal.Batch:

    NIA 13C028 Circumferential Oriented ~rch Unit Voltage:

    450 Pulse Width:

    220 Ax. Gain (dB):

    50 Circ. Gain (dB):

    N/A 10 Screen Div. =

    3 in. ot Sound Path Calibration Block Cal. Block No.

    BWD-PDl-304-01 Thickness o.5" -2.0*

    Dia.:

    Flat Gal. Blk. Temp....!!:_ Temp. Tool:

    29021141 Comp. Temp. ~

    Temp. Tool:

    29021141 Recordable lndication(s):

    Yes O No~

    Results:

    Accept.,,

    Reject O Percent Of Coverage Obtained > 90%:

    No-83.3".4 Shape:

    Contour:

    NIA Type; Ultragef II Calibration Signal Sweep Sound Path Round Mfg.:

    Sonotech Reflector Amplitude%

    Divil;ion Wedge Style:

    MSWQC NIA NIA WA NIA Exam Batch:

    13C028 Search Unit Cable NIA N/A NJ.A NIA RG-174 6'

    No. Conn.: 0 Type:

    Ultragel fl NIA NIA NIA Type:

    Length:

    Ni.A Mfg.:

    Sonotech NIA NIA NJ.A NIA Scan Coverage Upstream ~ Downstream~ Scan dB:

    50 --

    cwo CCW O Scan dB: NIA Exam Surface:

    OD Surface Condition:

    Ground (II Yes. Ref. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data:

    NIA I

    Reference Block Reference/Simulator BJock Serial No.:

    Type:

    Gain Signal

    ~=

    SooodPalh 171311 SS dB Reflector Amplitude%

    1" Angle Beam 42 SDH 40%

    ~-2 0.95" NIA NIA NIA NIA NIA NIA NIA N/A NJA NIA Comments: Cal Block BWO-PDl-304--01 demonstrat* to be -

    ultrasonically equivalent to Flaw Tech <;a* Block 22572.

    Baseline Exam. Weld Doc 2B.

    Examiner Level Ill £ *_ ~

    Date Reviewer Signature Date Crothers, Simon, P.

    8/14/2015

    .£)/;p-

    "1,//~

    Examiner Level NIA Signature Date Site Review

    ~~md-Date NIA at"'1.s II* /h~kc.,,.,,,.._;

    ~""'..L7T

    /~-1-;.S-Olher Level NIA Signature Date ANll Review Signature I

    Date J_ """"--'.~

    I NIA L~ ~~~..AN

    'o\\,..\\ \\<

    RS-20-012 Attachment 6 I

    rPage 55

    ~Exelon UT Calibratior **...;Xamination

    ~c. 10/1z./1s Site/Unit:

    BRW I

    2 Procedure:

    ER*AA*335-03f( \\

    Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    {.

    s c 10/12 /1s Report No.:

    UT *201S-010 Workscope:

    PSI Work Order No.:

    01S92238-08 Page:

    • 4 of 8

    Code:

    ASME 2001 Edition / 2003 Addenda CatJltem:

    NIA Location:

    CV Pump Room Drawing No.:

    FX-17

    ==

    Description:==

    Tee to Pipe System ID:

    CV Com pone n t ID: Field Weld 2 Size/Length:

    1.0" / 14.5" Thickness/Diameter:

    0.531* 14*

    Limitations:

    Tee Radius Start Time:

    0948 Finish Ti~:

    1019 Instrument Settings Search Unit Cal.

    Axial Oriented Search :unit Time Date Serial No.:

    0221JM Serial No.:

    15-SS Checks Calibration Signal Swjtep Manufacturer:

    GE Inspection Technologies Manufacturer:

    RTD Initial Cal.

    0749 8/14/2015 Reflector Amplitude %

    Divij>ion Sound Path Model:

    USN60SW Linearity:

    201 S-L-001 Size:

    2(7 x 10)mm Model:

    TRL2-Aust Inter. Cai.

    101S 8/14/2015 1* Notch 80%

    10.0 2.0*

    Delay:

    6.8100 Range:

    2.0*

    Freq.:

    2.0MHz Center Freq.:

    NIA Inter. Cai.

    1019 8/14/2015 NIA NIA NJ.A NIA M'llCalNel:

    0.228 Pulser Type:

    Square Exam Angie:

    Squint Angle:

    Inter. Cal.

    NIA NIA NIA NJ.A NIA so*

    2*

    Damping:

    5000hms Reject:

    Final Cal.

    1142 8/14/2015 NIA NIA

    ~A NIA 0%

    Measured Angle:

    so*

    Mode:

    Long PRF:

    SU Freq.:

    Couplant NIA NIA NI.A NIA Auto High 2.0 MHz Exit Point 0.35"

    1. of Elements:

    2 Frequency:

    2.0 MHz Rectify:

    Fullwave Config.:

    0-SBS Focus:

    -- Cal. Batch:

    FS-25 13C028 Circumferential Oriented S~arch Unit Voltage:

    450 Pulse Width:

    250 Ax. Gain (dB):

    59 Circ. Gain (dB):

    N/A 10 Screen Div. =

    2 in. of Sound Path Calibration Block Cal. Block No.

    BWD*PDl*304-01 Thickness 0.5". 2.0*

    Dia.:

    Flat Gal. Blk. Temp...!!_ Temp. Tool:

    29021141 Comp. Temp.

    108° Temp. Tool:

    29021141 Recordable lndication(s):

    Yes O No~

    Results:

    Accept "

    Reject O Percent 01 Coverage Obtained > 90"k:

    No-83.3%

    Contour:

    Type:

    Ultragel II Calibration Signal Sw~ep Sound Path Shape:

    RecL Flat Mfg.:

    Sonotech Reflector Amplitude%

    Division Wedge Style:

    Integral NIA NIA NI.A NIA Exam Batch:

    13C028 Search Unit Cable NIA N/A NI.A NIA RG-174 6'

    No. Conn.: o Type:

    Ultragel II NIA N/A WA NIA Type:

    Length: -

    Mfg.:

    Sonotech NIA NIA NIA NIA Scan Coverage Upstream O Downstream~ Scan dB:

    59 --

    cwo CCW O Scan dB: NIA Exam Surface:

    OD Surface Condition:

    Ground (If Yes, Ref. Attached Ullrasonic indicalion Report.)

    Info O Reviewed Previous Data*

    NIA Reference Block Reference/Simulator e'.iock Serial No.:

    Type:

    Gain Signal Sv!eep Sound Path 171311 SS dB Reflector Amplitude%

    Di~sion 1" Angle Beam 54 SOH 80%

    7..s 1.49.

    NIA NIA NIA WA N/A NIA NIA NIA WA NIA T

    Comments: Cal Block BWD*PDl-304-01 demonstrat~ to be ultrasonically equivalent to Flaw Tech ~I Block 22572.

    Baseline Exam. Weld Doc 28.

    Examiner Level Ill L..... ~

    Date Reviewer Signature I

    Date I

    Crothers, Simon, P.

    8/14/2015

    /[//,,,,_

    A//,,,. !

    Examiner Level NIA Signature Date Site Review Signature Date

    .NIA C!!,,,,.,~ #. _/hL~#MJ L. v..LZZ'"

    d.e:.~/?/µ.

    /0-/-/..S-Other Level NIA Signature Date ANll Review Signature I

    Date NIA

    \\..-c:~ """~~~

    J__ ~l...t

    .1..0\\..... \\\\~

    I I

    RS-20-012 Attachment 6 Page 56

    ~

    ~Exelon.

    Supplemental Report Su.111r:n~r:y N9.: NIA......

    Sketch or Photo:

    Work Package: 01692238-08 Weld: FW-2 Sketch 1: Coverage Plot Weld Crown Width: 1.0" Weld Length: 14.5" Counterbore DS: None Counterbore US: None limitation:

    0 I

    Tee radius obstructed US exams for 4.25"@ 180°.

    Flow...

    0.75" Profile @ 0° (TDC)

    US Coverage represents 10.25" of 14.5" weld length.

    OS Coverage represents 14.5" of 14.5" weld length.

    a.,.,.'& N* ""'~H/V d'Nmd 1*

    I

    £.(Ek"1 '-" JZT

    /0 1')

    Report No.:

    UT-2015-010 Page: _!__ of 8

    2*

    3" I

    I lo i

    ANI I ANH RIEVIEW

    , v\\~\\,~

    REVIEW DATE J_ "'-4.v:-..*

    RS-20-012 Attachment 6 Page 57

    419111 EE? Exelon.

    Supplemental Report

    $ummary No.: N/A_..

    Sketch or Photo:

    Work Package: 01692238-08 Weld: FW-2 Sketch 2: Coverage Plot 0

    I Report No.:

    UT-2015.010 Page:

    6 of 8

    1" 2"

    3" I

    I Note: 70° used to obtain remaining coverage, scan limited to area shown.

    Single sided access for 4.25" Pipe Far side of weld examined as per single sided access rules - No coverage credit taken.

    Coverage Cale Exam Length Result Ax Upst 10.25." of 14.5" 70.7%

    Ax Dnst 14.5" of 14.5" 100%

    Circ Upst 10.25" of 14.5" 70.7%

    • Circ Dnst
    • 14.5" of 14.5" 100%

    Total:

    341.4%

    Total/ 4:

    83.3%

    RS-20-01 2 Attachment 6 AN~ I ANH REVIEW

    \\ \\,_

    J

    ° "). \\~

    • 1ev1ew DATE t-'V...-..-Ju.......,

    Page so

    ~

    l§f? Exelon.

    Supplemental Report

    .:>umn:i~ry N.o.: ~/A

    ..== ----** -* 13.. r -***

    Sketch or Photo:

    Work Package: 01692238-08 Weld: FW-2 Sketch 3: Indication Plot Report No.:

    UT-2015-010 Page:

    7 of 8

    Flow

    @Root Geometry, seen intermittently 360° RS-20-012 Attachment 6 ANI I ANH REVIEW

    \\ \\,,...

    REVIEW DATE J.__~#0'\\:>" ~

    Page 59

    .:"'Exelon, Ultrasonic Indication Report Sc Io /12. /IS Site/Unit:

    BRW I

    2 Summary No.:

    NIA Workscope:

    PSI Search Unit Angle:

    60° 0

    Wo Location:

    Centerline Lo Location:

    TDC I

    MP Metal Path w

    Dist Comments:

    Field Weld2 Indication w

    Forward Angle No.

    Of Max NIA Of Max DAC w

    MP W1 MP 60° 1

    60%

    o.ss*

    1.2*

    NIA NIA Examiner Level 111

    (( -

    ~

    Crothers, Simon, P.

    ~

    v Examiner Level NIA Signature NIA Other Level NIA Signature NIA RS-20-012 Attachment 6 NIA Procedure:

    ER-AA-335-03,Jf I Outage No.: -------

    Procedure Rev.:

    c( 6

    ~e. 10/1'L/t.}eport. No.:

    UT-2015-cno '.

    Work Order No.:

    01692238-08 Page:

    8 of 8:

    @ Piping Welds O Ferritic Vessels

    ~ 2"T O Other NIA From Wo To S.U. At Maximum R esponse I

    =orward) 3ackward)

    Wo

    !w-CL' L sbt~ I

    -!---*-----f--DATtJM rrr Lo I

    !(!

    ---i::~

    6 0 J, J, -

    i Wl ~ \\\\mas \\VJ Backward L1 L

    L2 RBR Remarks NIA Of Max NIA Max NIA Amp.

    Of Of W2 MP Max Max NIA NIA NIA o*

    NIA NIA Root Geometry from US side.

    I I

    I I

    I I

    Date Reviewer Signature I

    Date 8/1412015

    /O/~

    /!//~

    Date Site Review Signature I

    Date I

    e.,.,, '-<. J./. /H&&~,n/ < "p;: e£.:-rrP?d-
    10-*l-15'"

    Date ANllAevieL Signature I

    Date

    ~.~.

    lflh*\\,c

    ~ Page 60

    -.r(

    ~Exelon.

    UT Calibratio.C.Aamination Site/Unit:

    BRW I

    2 Procedure:

    Summary No.:

    NIA Procedure Rev.:

    Workscope:

    PSI Wor1< Order No.:

    2CV-21-58 ER*AA-335-031 6

    01692238-08 iC i

    I Outage No.: I NIA Report No.: I UT*2015-009 Paga: ~

    ot 6

    Code: '

    ASME 2001 Edition/ 2003 Addenda cat.lltem:--

    NIA Location:

    -cv Pump Ro~ I Drawing ~9 *. ;-

    • F)<-17

    ==

    Description:==

    Valve to Tee

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~

    System ID:

    c;v I

    ComponenflQ: Field Weld 1 Size/length:

    1.0* / 14.5*

    Thickness/OiametGt:

    0.531* 14*

    .*. Single Sided Access /Tee Radii Start Time:

    0948 Finish Tim~:

    1019 Limitations:

    Cal Thie Cal Co Instrument Settings lo.:

    0221JM cturer:

    GE Inspection Technologies USN60SW Linearity:

    201 S-L--001 4.1716 Range:

    1.5*

    'Vel:

    0.1230.

    Pulser Type:

    Square g:

    SOOOhms Reject:

    0%

    Auto High SU Freq.:

    2.25MHz icy:

    2.25 MHz Rectify:

    Fullwave 450 Pulse Width:

    220 I (dB):

    20 Circ. Gain (dB):

    NIA

    reen Div.=

    1.5 In. of Sound Path Calibration Block

    kNo.

    BWD*PDl-304-01 iS o.5" -2.0*

    Dia.:

    Flat Temp. 86" Temp. Tool:

    29021141 amp.

    108° Temp. Tool:

    29021141 Search Unit Cal.

    Time Date Serial No.:

    580442 Checks Manufacturer:

    GEIT Initial Cal.

    0722 8/1412015 Inter. Cal.

    0948 8/14/2015 Size:

    0.25.

    Model:

    Comp-G Inter. Cal.

    1002 811412015 Freq.:

    2.25 MHz Center Freq.:

    NIA Inter. Cal.

    NIA Exam Angle:

    45*

    Squint Angle:

    NIA Final Cal.

    1137 8/1412015 Measured Angle: ~

    Mode:

    Shear Couplant Exit Point

    . 0.2*

    1. of Elements: -

    1-Cal. Batch:

    13C028 Config.:

    Single Focus:

    NIA Type:

    Ultragel II Shape:

    Round Contour:

    NIA Mfg.:

    Sonotech Wedge Style:

    MSWQC Exam Batch:

    13C028 Search Unit Cable Type:

    Ultragel II Type:

    RG-174 Length: 6' No. Conn.: ~ Mfg.:

    Sonotech Scan Coverage Upstream 0 Downstream~ Scan dB: 2!_

    Reference Block CW Ii!]

    CCW~ Scan dB:

    32 Serial No.:

    171311 SS Exam Surface:

    OD

    -- Type:

    1* Angle Beam Surface Condition:

    Ground Ultrasonic Indication ReDOrt.)

    I Axial Oriented Search junit Calibration Signal Sweep Sound Path DivlSion Reftector Amplitude%

    1* Notch 80%

    914 1.41*

    NIA NIA N(A NIA NIA NIA NIA NIA NIA NIA

    ~A NIA NIA NIA NfA NIA I

    Circumferential Oriented s;arch Unit Calibration Signal Sw~ep Sound Path Reflector Amplitude%

    Di~ion NIA NIA NIA NIA NIA NIA N(A NIA NIA NIA NlA NIA NIA NIA NiA NIA Reference/Simulator ~lock Gain Signal s,,yeep Sound Path dB Reflector Amplitude%

    Di~slon 20 SDH 25%

    .;.9 1,04*

    NIA

    'NIA NIA NIA NIA NIA NIA NIA NIA NIA R

    Results:

    Accept~

    0 Reject O

    ~

    Into O Comments: Cal Block BWD-PDl-304-01 demonstrate~ to be ultrasonically equivalent to Flaw Tech Cal Block 22572.

    Baseline Exam.

    I Percent Of Coverage Obtained > 90%:

    No-20.7%

    Reviewed Previous Data:

    NIA WeldDoc2A.

    Examiner Level Ill fl. CollCe Date Reviewer Signature fi//~

    Date Crothers, Simon, P.

    811412015 A//4-Examiner Level NIA Signature Date Site Review Signature.

    I Date NIA

    {!!.j, 11* 1 b J/,,/'he.k..,,._NA.J 1.~az.

    ~#/Nvh-. I lo-1-/S-Other Level NIA Signature Date ANll Review Signature I

    Date NIA L. ~Q.:i

    J..'~

    '...,..., " ~~

    ,.=!?' E&on UT Calibratio.C.... dmination IC I

    Site/Unit:

    BRW I

    2 Procedure:

    ER-AA-335-031 Outage No.: I NIA Summary No.:

    NIA Procedure Rev.:

    6 Report No.: I UT-2015~

    Workscope:

    PSI Work Order No.:

    0169223S-08 Page: j 2 of 6

    Code:

    ASME 2001 Edition / 2003 Addenda CatJltem:

    NIA Location:

    CV Pump Room Drawing No.:

    FX-17

    ==

    Description:==

    Valve to Tee System ID:

    CV


    ~~~~----~~~~~----~~~~--------~----~----~~~~~~~~~~~~~~~~~~~~~----~~--------~~~~~~t------~----~-----

    Co m pone n t ID: Field Weld 1 Size/Length:

    1.ou / 14.5*

    Thickness/Diamet8f o.s31*14*

    Limitations:

    Single Sided Access I Tee Radii Slart Time:

    0948 Finish Timy:

    1019 Instrument Settings Search Unit Cal.

    Axial Oriented Search pnit Time Date Serial No.:

    0221JM Serial No.:

    SB0625 Checks Calibration Signal Swpep illanufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech Initial Cal.

    0729 8/14/2015 Reflector Amplitude%

    Di~ion Sound Path illodel:

    USN 60SW Linearity:

    2015-L-001 Size:

    0.25° Model:

    Comp-G Inter. Cal.

    1002 8/1412015 1* Notch 80%

    ala 1.76*

    )elay:

    4.9441 Range:

    2.0° Freq.:

    2.25 MHz Center Freq.:

    NIA Inter. Cal.

    1009 811412015 NIA NIA ff!A NIA t111CaWel:

    0.1230 Pulser Type:

    Square Exam Angle:

    Inter. Cal.

    NIA NIA NIA NIA NIA 60° Squint Angle:

    NIA

    >amping:

    5000hms Reject:

    Final Cal.

    1138 811412015 NIA NIA NlA NIA 0%

    Measured Angle:

    59° Mode:

    Shear NiA

    ,RF:

    Auto High SU Freq.:

    Couplant NIA NIA NIA 2.25MHz Exit Point 0.25"

    1. of Elements:

    1 Circumferential Oriented S~arch Unit

    ~requency:

    2.2SMHz*

    Rectify:

    Fullwave Config.:

    -- Cal. Batch:

    13C028 Single Focus:

    NIA

    'oltage:

    450 Pulse Width:

    220 Shape:

    Conlour:

    Type:

    Ultragel II Calibration Signal sweep Sound Path Round NIA Reflector Amplitude%

    Division Mfg.:

    Sonotech Wedge Style:

    MSW QC NIA NIA NIA NIA

    .x. Gain (dB):

    39 Circ. Gain (dB):

    NIA Search Unit Cable Exam Batch:

    13C028 NlA NIA NIA NIA 10 Screen Div.=

    2 in. of Sound Path Type:

    RG-174 Length: 6' No. Conn.: o Type:

    Ultragel II NIA NIA N(A NIA Mfg.:

    Sonotech I

    Calibration Block Scan Coverage NIA NIA NIA NIA I

    al. Block No.

    8WD-PDl-304-o1 Upstream O Downstream~ Scan dB:

    45 Reference Block Reference/Simulator ~lock hickness o.5*-2.0° Dia.:

    Flat Gain Signal Sweep Sound Path cwo CCW 0 Scan dB: NIA Serial No.:

    171311 SS dB Reflector Amplitude% Di*'ision al. Bik. Temp. ~

    Temp. Tool:

    29021141

    -- Type:

    Exam Surface; OD 1

    • Angle Beam 39 SDH 50%

    .2 1.45.

    omp. Temp. ~

    Temp. Tool:

    29021141 Surface Condition:

    Ground NIA NIA

    • NIA II/A NIA R, ecordable lndication(s):

    Yes O No~

    NIA NIA NIA WA NIA Results:

    Accept o!£ Reject O Percent 01 Coverage Obtained > 90%:

    (If Yes, Ref. Attached Ultrasonic Indication Report.)

    Info O Comments: Cal Block BWD-PDl-304-o1 demonstra~d to be ultrasonically equivalent to Flaw Tech qa1 Block 22572.

    Baseline Exam. Weld Doc 2A.

    I No-20.7%

    Reviewed Previous Data*

    NIA Examiner Level Ill

    ~ f_. ~

    Date Reviewer Signature Date Crothers, Simon, P.

    8/1412015

    .it.) /"I-A-1/d-

    ~

    Examiner Level NIA Signature Date Site Review

    ~re

    /

    Date NIA

    "'!../.l"/.s JI, /17~-k~,v L.v.LZC

    • "'#-~c

    /C-/*'.>.

    Other Level NIA Signature Date ANll Review Signature Date NIA

    ~

    """'"~"\\~....,...J ck ~-

    \\.c:>-"").-\\.S'"

    RS-20-012 Attachment 6 I Page 62

    ~Exelon UT Calibration,... xamination Site/Unit:

    BRW 2

    Procedure:

    ER*AA*335-031 Outage No.:

    NIA Summary No.:

    NIA Procedure Rev.:

    6 Report No.: : UT*2015-o09 Workscope:

    PSI Work Order No.:

    01692238-08 Page:

    3 of 6

    Code:

    ASME 2001 Edition I 2003 Addenda CatJltem:

    NIA Location:

    CV Pump Room Drawing No.:

    FX*17 Desctiption: Valve to Tee System ID:

    CV

    ~~~~-~----~---~-~~-~-~~~~~--~-~~-~~~--~--~--~--~-~-~--~-...;--~-----

    Component ID: Field Weld 1 Size/length:

    1.0* / 14.5*

    Thickness/Diameter:

    0.531*14*

    Limitations:

    Single Sided Access I Tee Radii Start Time:

    0948 Finish Tim':

    1019 Instrument Settings Search Unit Cal.

    Axial Oriented Search '.Unit Time Date Serial No.:

    0221JM Serial No.:

    SB0419 Checks sw8ep Initial Cal.

    Calibration Signal Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    GEIT 0735 8114/2015 Reflector Amplitude%

    DiviSion Model:

    USN60SW Linearity:

    2015*L-001 Size:

    0.25" Model:

    Comp-G Inter. Cal.

    1009 8114/2015 1* Notch 80%

    917 2.s2*

    Delay:

    5.8547 Range:

    3.o*

    Freq.:

    2.25 MHz Center Freq.:

    NIA Inter. Cal.

    1015 8/14/2015 NIA NIA NIA NIA M't1Cawe1:

    0.1230 Pulser Type:

    Square Exam Angle:

    Inter. Cal.

    NIA NIA N/A NIA NIA 10*

    Squint Angle:

    NIA Damping:

    5000hms Reject:

    Final Cal.

    1139 8/1412015 NIA NIA NiA NIA 0%

    Measured Angle:

    10*

    Mode:

    Shear NiA PRF:

    Auto High SU Freq.:

    2.25 MHz Exit Point Couplant NIA NIA N/A 0.3*

    1. of Elements:

    1 Frequency:

    2.25MHz Rectify:

    Fullwave Config.:

    Single Focus:

    HI-;:-- Cal. Batch:

    13C028 Circumferential Oriented S.arch Unit Voltage:

    450 Pulse Width:

    220 Ax. Gain (dB):

    50.

    Circ. Gain (dB):

    N/A 10 Screen Div.=

    3 in. of Sound Path Calibration Block Cal. Block No.

    BWD-POl-304-D1 Thickness 0.5* *2.0*

    Dia.:

    Flat Cal. Blk. Temp...!!:._ Temp. Tool:

    29021141 Comp. Temp. ~

    Temp. Tool:

    29021141 Recordable lndication(s):

    Yes O No~

    Results:

    Accept.,,

    Reject O Percent Of Coverage Obtained > 900.4:

    No-20.7%

    Shape:

    Round Contour:

    NIA Type:

    Ultragel II Calibration Signal S~ep Sound Path Mfg.:

    Sonotech Reflector Amplitude%

    Oivi$ie>n Wedge Style:

    MSWOC NIA NIA NiA NIA Exam Batch:

    13C028 Search Unit Cable NIA NIA NIA NIA RG*174 6' No. Conn.: O Type:

    Ultragel II NIA NIA NIA NIA Type:

    Length: -

    Mfg.:

    Sonotech NIA N/A NIA NIA Scan Coverage Upstream O Downstream~ Scan dB:

    50 cwo ccw D Scan dB: NIA Exam Surface:

    00 Surface Condition:

    Ground (II Yes, Ref. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data:

    NIA Reference Block Reference/Simulator ~lock Serial No.:

    Type:

    Gain Signal Sweep Sound Path 171311 SS dB Reflector Amplitude "lo Division 1

    • Angle Beam 42 SDH 40%

    ~.2 0,95*

    NIA N/A NIA NIA NIA NIA NIA NIA NIA NIA Comments: Cal Block BWD-PD1*304-D1 demonstrated to be ultrasonically equivalent to Flaw Tech ~al Block 22572.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill

    ~

    '_ ~

    Date Reviewer Signature Date Crothers, Simon, P.

    8/1412015

    /f.?/;t-

    /(.)/,,,,.... '

    Examiner Level N/A Signature Date Site Review sd Date NIA

    ~t,..'$ II.,n,~~*-v i..,1//4

      1. ~4 /"-/*~..r*

    Other Level N/A Signature Date ANll Review Signature Date NIA LeE'".. *-** -

    ~

    \\..-

    -" b l..e.\\~'u-

    .-~

    RS-20-012 Attachment 6 f?age 63

    £7' Exelon UT Calibratio.amination Sile/Unit:

    BRW 2

    Procedure:

    ER*AA-33S-031 Outage No.:

    I NIA Summary No.:

    NIA Procedure Rev.:

    6 Report No.:

    UT*2015-o09 Workscope:

    PSI Work Order No.:

    01692238--08 Page: : 4 of 6

    Code:

    ASME 2001 Edition / 2003 Addenda Cat.ntem:

    NIA Location:

    CV Pump Room Drawing No.:

    FX-17

    ==

    Description:==

    Valve to Tee System ID:

    CV


    ~-------~~~~--~~~~~~~~--------~~----------..------~

    Component ID: Field Weld 1 Size/Length:

    1.0* / 14.5n Thickness/Diamete~

    0.531* 14*

    Limitations:

    Single Sided Access Start Time:

    0948 Finish Time:

    1019 Instrument Settings Search Unit Cal.

    Axial Oriented Search tlnit Time Date Serial No.:

    0221JM Serial No.:

    15-66 Checks calibration Signal s weep Manufacturer:

    GE Inspection Technologies Manufacturer:

    RTD Initial Cal.

    0749 811412015 Reflector Amplitude%

    Divli;ion Sound Path Model:

    USN60SW Linearity:

    2015*L-001 Size:

    2(7 x 10)mm Model:

    TRL2*Aust Inter. Cal.

    1016 811412015 1" Notch 80%

    1Q.O 2.0*

    Delay:

    6.8100 Range:

    2.0*

    Freq.:

    2.0MHz Center Freq.:

    NIA lnler. Cal.

    1019 811412015 NIA NIA NIA NIA M'tl CalNel:

    0.228 Pulser Type:

    Square Squint Angle:

    Inter. Cal.

    NIA NIA NIA N(A NIA Exam Angle:

    60" 2*

    Damping:

    SOOOhms Reject:

    Final Cal.

    1142 811412015 NIA NIA NIA NIA 0%

    Measured Angle:

    so*

    Mode:

    Long PRF:

    SU Freq.:

    Couplant NIA NIA NIA NIA Auto High 2.0MHz Exit Point 0.35"

    1. of Elements:

    2 Frequency:

    2.0MHz Rectify:

    Fullwave

    -- Cal. Batch:

    13C028 Circumferential Oriented Search Unit Config.:

    0-SBS Focus:

    FS-25 Voltage:

    450 Pulse Width:

    250 Ax. Gain (dB):

    59 Circ. Gain (dB):

    NIA 10 Screen Div.=

    2 in.of Sound Path Calibration Block Cal. Block No.

    BWD-POl-304-01 Thickness 0.5". 2.0*

    Dia.:

    Flat Cal. Blk. Temp. 86° Temp. Tool:

    29021141 Comp. Temp.

    108" Temp. Tool:

    29021141 Recordable lndlcation(s):

    Yes O No~

    Results:

    Accepl.,,

    Reject O Percent Of Coverage Obtained > 90%:

    No-20.7%

    Shape:

    Type:

    Ultragel II Calibration Signal Sweep Sound Path Rect.

    Contour:

    Flat Mfg.:

    Sonotech Reflector Amplitude%

    Di~lon Wedge Style:

    Integral NIA NIA NIA NIA Search Unit Cable Exam Batch:

    13C028 NIA NIA NIA NIA RG-174 6'

    No. Conn.: O Type:

    Ultragel II NIA NIA NIA NIA Type:

    Length: -

    Mfg.:

    Sonotech NIA NIA N(A NIA Scan Coverage Upstream O Downstream~ Scan dB:

    59 --

    cwo CCWO Scan dB: NIA Exam Surface:

    OD Surface Condition:

    Ground (II Yes. Rel. Attached Ultrasonic Indication Report.)

    Info O Reviewed Previous Data:

    NIA Reference Block Reference/Simulator Block Serial No.:

    Type:

    Gain Signal Sweep 171311 SS Sound Path dB Reflector Amplitude% Diliision 1 " Angle Beam 54 SDH 80"..4 7.5 1.49.

    NIA NIA N/A NJA NIA NIA N/A N/A N/A NIA Comments: Cal Block BWD-PDl-304-01 demonstrated to be ultrasonically equivalent to Flaw Tech Cal Block 22572.

    Baseline Exam. Weld Doc 2A.

    Examiner Level Ill

    ~ "'-. ~

    Date Reviewer Signature Date Crothers, Simon, P.

    8/1412015 A,,?/,.,.....

    ,,,0//1'-

    Examiner Level NIA Signature Date Site Review Signature Date N/A e.t,,~'s d*/?1~,e~~/(,)

    .4v~ a*#d-

    /&:>-/*/S-Other Level N/A Signature Date ANll Review Signature Date N/A LEE \\v..~~~

    J__ "'-,....

    \\.<>\\'l,..\\ £ RS-20-012 Attachment 6 Page 64

    Supplemental Report

    ~Exelon.

    Sketch or Photo:

    I

    ,/

    Work Package: 01692238-08 Weld: FW-1 Sketch 1: Coverage Plot Weld Crown Width: 1.0" Weld Length: 14.5" Counterbore OS: None Counterbore US: None Limitations:

    Single sided access due to valve.

    0 1"

    I I

    Tee radii obstructed exams for 4.25" each@ 0° and 180°.

    Examined 3" of weld length @ 90° & 3" of weld length @ 270°.

    Examined 6" of 14.5" weld length.

    Flow 0.76" Profile @ 90° Coverage represents 6" of 14.5" Exam Coverage = 50% as per single sided access rules.

    e-t~* '-' )I. I* c.-/<-t' ~""

    e/-*7'1-n4d--

    £)(&f..t?""' """" 07 10 15 Report No.:

    UT *2015-009 Page:

    5 of 6

    2*

    3" I

    I RS-20-012 Attachment 6 ANI I ANH REVIEW

    \\ 0 \\-a.-\\\\ \\

    REVIEW DATE cL ~--U?aae65

    ~*Exelon.

    Supplemental Report Sketch or Photo:

    Work Package: 01692238-08 Weld: FW-1 Sketch 2: Coverage Plot 0

    I Report No.:

    UT-2015-009 Page:

    6 of 6

    1" 2"

    3" I

    I I

    Note: 70° used to obtain remaining near side coverage, scan limited to area shown.

    )

    /

    60° RL Tee Far side of weld examined as per single sided access rules - No coverage credit taken.

    Coveraae Cale Exam Lenath Ax Upst O" of 14.5" Ax Dnst 6" of 14.5" Circ Uost O" of 14.5" Circ Dnst 6" of 14.5" Total:

    Total/ 4:

    RS-20-012 Attachment 6 Result 0%

    41.4%

    0%

    41.4%

    82.8%

    20.7%

    d41f/1td-ex~Jt)I(/ t.v OI 10** 1-1~

    ANI I ANll REVIEW to)'v\\'C' REVIEW DATE ~a~

    Fvel'O~

    -A I.

    UT Calibration/E:.Aamination 2FW-09-25 Site/Unit:

    BRW 2

    Procedure:

    ER-AA-335-030 Outage No.:

    A2R18 Summary No.:

    2-R01.11.2032 Procedure Rev.:

    4 Report No.:

    A2R18-UT-015 Workscope:

    ISi Work Order No.:

    01757348-01 Page:

    of 4

    Code:

    ASME XI, 2001 Ed, 2003 Ad Cat./ltem:

    R-AIR1.11-3 Location:

    IMB LOOP A,R-42 Drawing No.:

    2FW-09

    ==

    Description:==

    ELBOW - SG 2RC01 BA AF NOZZLE System ID:

    FW

    ~--~-----~--~-----------------~------~--~--~--~--~--~--~----------

    Component ID: 2FW-OS-25 Size/Length:

    6" /20.8" Thickness/Diameter:

    0.719" / 6" Limitations:

    Nozzle Configuration Start Time:

    1339 Finish Time:

    1416 Serial No.:

    Manufacturer:

    Instrument Settings 0221JM GE Inspection Technologies Model:

    USN 60SW Linearity:

    2015-L-003 Delay:

    3.9866 Range:

    2.0" M'tl CalNel:

    0.1270 Pulser Type:

    Square Damping:

    5000hms Reject:

    0%

    PRF:

    Auto High SU Freq.:

    5.0 MHz Frequency:

    5.0 MHz Rectify:

    Fullwave Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    18 Gire. Gain (dB):

    N/A 10 Screen Div. =

    2 in. of Sound Path Cal. Block No.

    Calibration Block 22571

    ~---------------

    Thickness 0.5" to 2.0" Dia.:

    Flat Cal. Blk. Temp...!!:_ Temp. Tool:

    29021141 Comp. Temp.

    82° Temp. Tool:

    29021145 Recordable lndication(s):

    Yes '

    No !'111 Search Unit Cal.

    I Time I Date I

    Serial No.:

    SD1107 Checks Manufacturer:

    KB-A~rotech Initial Cal.

    1015 10/9/2015 Size:

    0.375" Model:

    Comp-G Inter. Cal.

    1338 10/9/2015 Inter. Cal.

    1346 10/9/2015 Freq.:

    5.0 MHz Center Freq.: ~

    Inter. Cal.

    N/A Exam Angle:

    45° Squint Angle:

    N/A

    ~~

    Final Cal.

    18041 10/9/2015 Measured Angle:

    47° Shear Mode: -----

    Couplant Exit Point 0.3"

    1. of Elements: _1_ Cal. Batch:

    15E082 Config.:

    Single Focus:

    N/A Type:

    Ultragel II Shape:

    Round Contour:

    N/A Mfg.:

    Sonotech Wedge Style:

    Exam Batch:

    MSW QC 13M026 Search Unit Cable Type:

    Ultragel II Type:

    RG-174 Length: ~

    No. Conn.: o Mfg.:

    Sonotech Scan Coverage Upstream ['Ill Downstream !'fl Scan dB:

    38 Reference Block cw !'Ill CCW 1'fJ Scan dB:

    44 Serial No.:

    33694 cs Exam Surface:

    OD Type:

    1" Angle Beam Surface Condition:

    Ground (If Yes, Ref. Attached Ultrasonic Indication Report.)

    Info Comments: None Results:

    Accept iv'i Reject, i Percent Of Coverage Obtained > 90%:

    Examiner Level 11 Salley, Michael Examiner N/A Other N/A Level N/A Level NIA RS-20-012 Attachment 6 No - 87.3%

    Reviewed Previous Data:

    Yes Date I Reviewer 10/9/2015 SIMOIJ CA.()/HE/l.J L-111 Signature Date I Site Review

    "'1\\~ \\ \\:G r Signature Date I ANll Review L 1cSt \\'--\\A-~~ r.-....\\ ~

    Axial Oriented Search Unit Calibration Signal Sweep Sound Path Reflector Amplitude%

    Division 1" Notch 80%

    7.3 1.460" NIA N/A N/A N/A NIA N/A NIA N/A NIA N/A NIA N/A NIA N/A N/A N/A Circumferential Oriented Search Unit Calibration Signal Sweep Sound Path Reflector Amplitude %

    Division NIA N/A N/A N/A NIA N/A N/A N/A NIA N/A NIA N/A NIA N/A NIA N/A Reference/Simulator Block Gain Signal dB Reflector Amplitude%

    18 SDH 20%

    NIA NIA N/A N/A N/A N/A J--

    Sweep Sound Path Division 2.2 0.439" N/A N/A N/A N/A to/1+/ts Date Date 10-1S'"*1>

    Date

    \\.0 \\~\\,s Page 67

    Exelon Site/Unit:

    BRW Summary No.:

    2-R01.11.2032 Workscope:

    ISi Code:

    ASME XI, 2001 Ed, 2003 Ad Drawing No.:

    2FW-09 System ID:

    FW 2

    UT Calibratior.. _xamination Procedure:

    ER-AA-335-030 Outage No.:

    A2R18 Procedure Rev.:

    4 Report No.:

    A2R18-UT-015 Work Order No.:

    01757348-01 Page:

    2 of 4

    Cat./ltem:

    R*A/R1.11-3 Location:

    IMB LOOP A,R-42

    ==

    Description:==

    ELBOW - SG 2RC01 BA AF NOZZLE

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-

    Component ID: 2FW-09-25 Size/Length:

    6" /20.8" Thickness/Diameter:

    0.719" / 6" Limitations:

    Nozzle Configuration Start Time:

    1339 Finish Time:

    1416 Instrument Settings Search Unit Cal.

    Axial Oriented Search Unit Time Date Serial No.:

    0221JM Serial No.:

    SD1092 Checks Initial Cal.

    Calibration Signal Sweep Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech 1017 10/9/2015 Reflector Amplitude%

    Division Model:

    USN60SW Linearity:

    2015-L-003 Size:

    0.375" Model:

    Comp-G Inter. Cal.

    1347 10/9/2015 1" Notch 80%

    6.7 2.0" Delay:

    6.5678 Range:

    3" Freq.:

    5.0 MHz Center Freq.:

    NIA Inter. Cal.

    1359 10/9/2015 NIA N/A NIA N/A M'tl CalNel:

    0.1270 Pulser Type:

    Square Inter. Cal.

    N/A NIA NIA NIA NIA Exam Angle:

    60° Squint Angle:

    N/A Reject:

    Final Cal.

    1805 10/9/2015 NIA N/A NIA N/A Damping:

    500*0hms 0%

    Measured Angle:

    60° Mode:

    Shear Couplant NIA N/A NIA N/A PRF:

    Auto High SU Freq.:

    5.0 MHz Exit Point

    1. of Elements:

    0.35" 1

    Frequency:

    5.0 MHz Rectify:

    Fullwave Config.:

    Single Focus:

    -- Cal. Batch:

    N/A 15E082 Circumferential Oriented Search Unit Voltage:

    450 Pulse Width:

    100 Shape:

    Round Contour:

    N/A Type:

    Ultragel II Mfg.:

    Sonotech Wedge Style:

    MSWQC Ax. Gain (dB):

    40.5 Gire. Gain (dB):

    N/A Search Unit Cable Exam Batch:

    13M026 10 Screen Div.=

    3 in. of Sound Path Type:

    RG-174 Length:

    6 No. Conn.: o Type:

    Ultragel II Mfg.:

    Sonotech Calibration Block Scan Coverage Cal. Block No.

    22571 Upstream M Downstream L Scan dB: ~

    Reference Block Thickness 0.5" to 2.0" Dia.:

    Flat CW~]

    CCW ~l Scan dB: 50.5 Serial No.:

    33694 cs Cal. Blk. Temp. no Temp. Tool:

    29021141 Exam Surface:

    OD Type:

    1" Angle Beam Comp. Temp.

    82° Temp. Tool:

    29021145 Surface Condition:

    Ground Recordable lndication(s):

    Yes 1-J No

    [~

    (If Yes, Ref. Attached Ultrasonic Indication Report.)

    Results:

    Accept '°'

    Reject [ J Info, I Comments: None Percent Of Coverage Obtained > 90%:

    No-87.3%

    Reviewed Previous Data:

    Yes Examiner Level II Salley, Michael Date I Reviewer 101912015 S ff'1 ON CA.QIH ii./1-S Examiner Level N/A Signature Date I Site Review N/A

    rel'-... \\IV\\;\\'*("

    Other Level N/A N/A Signature Date I ANll Review L- \\::;"E. \\'---\\A-t.o. 1"3,.. ~

    Pt )'-)

    RS-20-012 Attachment 6 Calibration Signal Sweep Sound Path Reflector Amplitude%

    Division NIA N/A NIA N/A NIA N/A N/A N/A NIA N/A NIA N/A NIA N/A N/A N/A Reference/Simulator Block Gain Signal dB Reflector Amplitude%

    31 SDH 60%

    NIA N/A N/A N/A N/A N/A Sweep Sound Path Division 2.2 0.650" N/A N/A NIA N/A Date 10 ft+!' S Date Jo-1<::*1 Date 1...0\\u;-\\,5 Page 68

    -~

    xeio

    .. n L

    ~'i UT Calibration/l:Aamination Site/Unit:

    BRW 2

    Procedure:

    ER-AA-335-030 Outage No.:

    A2R18 Summary No.:

    2-R01.11.2032 Procedure Rev.:

    4 Report No.:

    A2R18-UT-015 Workscope:

    ISi Work Order No.:

    01757348-01 Page:

    3 of 4

    Code:

    ASME XI, 2001 Ed, 2003 Ad Cat/Item:

    R-A/R1.11-3 Location:

    IMB LOOP A,R-42 Drawing No.:

    2FW-G9

    ==

    Description:==

    ELBOW - SG 2RC01 BA AF NOZZLE System ID:

    FW

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-~~-~--------~---~--~--~--~--~-

    Component ID: 2FW-09-25 Size/Length:

    6" / 20.8" Thickness/Diameter:

    0.719" /6" Limitations:

    Nozzle Configuration Start Time:

    1339 Finish Time:

    1416 Instrument Settings Search Unit Cal.

    Axial Oriented Search Unit Time Date Serial No.:

    0221JM Serial No.:

    OOT2TW Checks Calibration Signal Sweep Sound Path Manufacturer:

    GE Inspection Technologies Manufacturer:

    KB-Aerotech Initial Cal.

    1018 10/9/2015 Reflector Amplitude%

    Division Model:

    USN 60 SW Linearity:

    2015-L-003 Size:

    0.375" Model:

    Comp-G Inter. Cal.

    1410 10/9/2015 1" Notch 80%

    7.3 2.905" Delay:

    7.6488 Range:

    4.0" Freq.:

    5.0 MHz Center Freq.:

    NIA Inter. Cal.

    1416 10/9/2015 NIA N/A NIA N/A M'tlCalNel:

    0.1270 Pulser Type:

    Square Inter. Cal.

    N/A N/A N/A NIA N/A Exam Angle:

    70° Squint Angle:

    N/A Final Cal.

    1806 10/9/2015 NIA N/A NIA N/A Damping:

    5000hms Reject:

    0%

    Measured Angle:

    70° Mode:

    Shear Couplant NIA N/A NIA N/A PRF:

    Auto High SU Freq.:

    5.0 MHz Exit Point 0.35"

    1. of Elements:

    1 Frequency:

    5.0 MHz Rectify:

    Fullwave

    -- Cal. Batch:

    15E082 Circumferential Oriented Search Unit Config.:

    Single Focus:

    N/A Voltage:

    450 Pulse Width:

    100 Ax. Gain (dB):

    38.5 Gire. Gain (dB):

    N/A 10 Screen Div.=

    4 in. of Sound Path Calibration Block Cal. Block No.

    22571 Thickness 0.5" to 2;0" Dia.:

    Flat Cal. Blk. Temp.

    770 Temp. Tool:

    29021141 Comp. Temp.

    82° Temp. Tool:

    29021145 Recordable lndication(s):

    Yes I J No !'lfi Results:

    Accept i,tl Reject I I Percent Of Coverage Obtained > 90%:

    Examiner Level 11 Salley, Michael Examiner N/A Other N/A Level N/A Level NIA RS-20-012 Attachment 6 No - 87.3%

    Shape:

    Round Contour:

    N/A Type:

    Ultragel II Mfg.:

    Sonotech Wedge Style:

    MSW QC Exam Batch:

    13M026 Search Unit Cable Type:

    RG-174 Length:

    6 No. Conn.: 0 Type:

    Ultragel II Mfg.:

    Sonotech Scan Coverage Upstream i,tl Downstream. l Scan dB: 44.5 Reference Block CW LJ ccw Scan dB: N/A Serial No.:

    33694 cs Exam Surface:

    OD Type:

    1" Angle Beam Surface Condition:

    Ground (If Yes, Ref. Attached Ultrasonic Indication Report.)

    Info [ !

    Reviewed Previous Data:

    Signature Comments: None Yes Date I Reviewer 1ot9/2015IL"1.... -., cAIJTHEfJ.5 L*/11 Date I Site Review

    l...~ ('n\\\\\\QC" Date I ANll Review L-t'"E 't-\\. ~"" P::. p,-t->,.,.._,.

    Calibration Signal Sweep Sound Path Reflector Amplitude%

    Division NIA N/A N/A N/A N/A N/A NIA NIA NIA N/A N/A N/A NIA N/A NIA N/A Reference/Simulator Block Gain Signal dB Reflector Amplitude%

    31 SDH 50%

    N/A NIA N/A N/A N/A NIA

    '1ir J__

    Sweep Sound Path Division 2.3 0.919" N/A N/A NIA NIA Date 10/t+/ tS Date llJ -I~ *IS° Date

    \\ D \\\\.;S:"\\ \\5" Page 69

    ,__ Exelon Supplemental Report Report No.:

    A2R18-UT-015 Page:

    4 of 4

    Summary No.: 2-R01.11.2032 Examiner: Salley, Michael vF f S Level:

    II Reviewer: L..,_ CciL Date: 10/1+/ls Site Review: ;:r,.,..., m;\\\\*C' -1'"1 ~

    T1f" Date:

    10 **CS**~

    Examiner: N/A Level:

    N/A

    ~~~~~~~~~~

    Other: N/A Level:

    N/A ANll Review:L~ µ.-. U\\i3A~ll-1 lV...t~ Date: \\.:. \\ '~\\,S-

    ~~~~~~~~~-

    CW1filf<1\\5rder: 01757348-01 Weld: 2FW-09-25 Sketch 1 : Coverage Plot Sketch or Photo:

    Flow 0.75" No Axial Exam:

    _.....;:::::..,~---"'."'°,--,......-

    0.25(0. 55 + 0.4 )/2

    __ ' -~x0. 2)/2=0. 15in' Exam Area: (0.25 x 0.25) + 0.8(0.25 + 0.20)/2 + 0.55(0.20 + 0.25)/2 + (0.9 x 0.25) = 0.59 in2 Axial Coverage: (0.59 - 0.15) I 0.59 = 7 4.6%

    Circ Coverage: 100%

    Total Coverage: (74.6 + 100)/2 = 87.3%

    Weld Crown Width: 1.3" Counterbore US:

    1.35" From Root Counterbore OS: None Detected RS-20-012 Attachment 6 0

    I 1"

    2" 3"

    I Page 70

    ISi Ultrasonic Scan Plan Component Information Site I Unit:

    Braidwood 2 Cal Std.:

    CS Alternate/ 1.0" Outage or Year:

    A2R18 /Fall 2015 Material: cs LTP#:

    Norn. Diameter:

    6.0" Component ID:

    2FW-09-25 Norn. Thickness:

    0.719" Procedure:

    ER-AA-335-030 R4 Configuration:

    Elbow to Nozzle System:

    Feedwater Weld Width:

    Measure Drawing / lso:

    2FW-09 Weld Length: 20.8" Code Class:

    1 Exam Volume:

    See R-A sketch Code Category:

    R-A Accessible Sides:

    1 Code Item:

    R1.11 Limitations: Single Sided Access Circ Exam: Maximum refracted angle to impinge on ID:

    51° Check Previous Date I Verify Measurements & Conditions I Report probe lift-off conditions.

    Equipment I Examination Information Probes Exams Angle Mode Size Frequency Axial I Perpendicular Circ I Parallel 45° Shear 0.375" 2.25 or 5.0 Yes Yes 60° Shear 0.375" 2.25 or 5.0 Note 1 Note 2 70° Shear 0.375" 2.25 or 5.0 Yes I Note 3 No

    1.

    If 45° probe cannot achieve 100% coverage by scanning across flush weld crown, then perform 60° axial exam.

    2. If 45° probe cannot achieve 100% coverage by scanning on flush or flat-topped weld crown, then perform 60° circ exam from base metal, skewed into weld root area. 60° will impinge on ID at skew angles >43°.
    3.

    70° axial exam due to single sided access.

    4. Take T & Cat LO, look for counterbore.
    5. Measure weld crown width.
    6.

    From previous data profile, this appears to be a single sided exam. Weld appears to be in the wrong location on previous coverage plot.

    Entered by Lev Ill Signature Date

    /\\

    Simon Crothers L~~~

    09/24/15

    • ( )V '1lt' q. SD.,c;-

    RS-20-012 Attachment 6 Page 71

    Exam Weld Component ID Description Requirements (System)

    (Figure No.)

    and Method Elbow-to-IWC-2500-7(a) 1Sl-39-08 Valve Weld Volumetric (SI)

    (UT)

    Valve-to-Pipe IWC-2500-7(a) 1Sl-39-08A Weld Volumetric (SI)

    (UT)

    Elbow-to-IWC-2500-7(a) 1Sl-39-25 Valve Weld Volumetric (SI)

    (UT)

    Valve-to-Pipe IWC-2500-7(a) 1Sl-39-25A Weld Volumetric (SI)

    (UT)

    Pipe-to-Valve IWC-2500-7(a) 1Sl-39-25B Weld Volumetric (SI)

    (UT)

    ATTACHMENT 7 Corrected Tables 13R-18.1 and 13R-18.2 Table IJR-18.1 Braidwood, Unit 1 List of Components with Limited Examination Coverage Exam Normal Operating Exam Angle/

    Category/

    Outage Material of Diameter/

    Conditions Frequency (MHz) I Actual Item Examined Construction Thickness (Pressure I Mode Coverage Number Temperature)

    Elbow: SA403 TP304 O' I 4.00 I Long R-A A1R16 Valve: SA479 4" I 0.531 "

    2485 psig 45' 12.25 1 Shear 50.0%

    R1.20 (PSI}

    TP316 176 deg-F 60' I 2.00 I Long Weld:

    ER308/308L Valve: SA479 TP316 O' I 4.00 I Long R-A A1R16 Pipe: SA376 4" I 0.531 "

    2485 psig 45' 12.25 1 Shear 50.0%

    R1.20 (PSI}

    TP304 176 deg-F 60' I 2.00 I Long Weld:

    ER308/308L Elbow: SA403 TP304 O' I 4.00 I Long R-A A1R16 Valve: SA479 4" I 0.531 "

    2485 psig 45' I 2.25 I Shear 50.0%

    R1.20 (PSI}

    TP316 176 deg-F 60' 12.00 I Long.

    Weld:

    45' I 5.00 I Shear ER308/308L Valve: SA479 TP316 O' I 4.00 I Long R-A A1R16 Pipe: SA376 4" I 0.531 "

    2485 psig 45' I 2.25 I Shear 50.0%

    R1.20 (PSI)

    TP304 176 deg-F 60' 12.00 I Long Weld:

    ER308/308L Pipe: SA376 TP304 R-A A1R16 Valve: SA479 4" I 0.531 "

    2485 psig 45' 12.25 1 Shear 50.0%

    R1.20 (PSI)

    TP316 176 deg-F 60' I 2.00 I Long Weld:

    ER308/308L Appendix VIII Remarks Qualified Exam Examination was limited due to valve configuration and one-sided exam.

    Yes (Reference 1, Attachment 2, Pages 2 and 3)

    Examination Results - No recordable indications.

    Examination was limited due to valve configuration and one-sided exam.

    Yes (Reference 1, Attachment 2, Pages 4 and 5)

    Examination Results - No recordable indications.

    Examination was limited due to valve configuration and one-sided exam.

    (Attachment 5, Pages 1 - 8)

    Yes Examination Results - Root geometry indication, one embedded weld flaw acceptable to IWB-3514 preservice examination acceptance standards.

    Examination was limited due to valve configuration and one-sided exam.

    Yes (Reference 1, Attachment 2, Pages 9 and 10)

    Examination Results - No recordable indications.

    Examination was limited due to valve configuration and one-sided exam.

    Yes (Reference 1, Attachment 2, Pages 11 and 12)

    Examination Results - No recordable Indications.

    Reference 1. Letter from D. Murray (Exelon Generation Company, LLC) to U.S. NRC, "Relief Request Associated with the Third Ten-Year lnservice Inspection Program Interval," dated August 27, 2019 (ML19239A156)

    Note: The following systems and their abbreviations are listed here: Auxiliary Feedwater (AF), Chemical and Volume Control System (CV), Pressurizer (RY), Feedwater (FW), Reactor Coolant (RC), Safety Injection (SI)

    Page 1 of 6

    Exam Weld Requirements Component ID Description (Figure No.)

    (System) and Method 1CV-22-30 Valve-to-Tee IWC-2500-7(a)

    (1CV109-Weld Volumetric 4/FW-1)

    (CV)

    (UT)

    Nozzle N1-to-IWB-2500-7 PZR Shell 1PZR-01-N1 Volumetric Weld (UT)

    (RY)

    Nozzle N4A-IWB-2500-7 1PZR to-PZR Shell Volumetric N4A Weld (UT)

    (RY)

    ATTACHMENT 7 Corrected Tables 13R-18.1 and 13R-18.2 Table IJR-18.1 Braidwood, Unit 1 List of Components with Limited Examination Coverage Normal Exam Operating Exam Angle/

    Category/

    Outage Material of Diameter/

    Actual Conditions Frequency (MHz) I Item Examined Construction Thickness (Pressure I Mode Coverage Number Temperature)

    Valve: SA351 CF8M R-A A1R18 Tee: SA403 2485 psig 45° 12.25 1 Shear 50.0%

    4" I 0.531 "

    60° I 2.00 I Long.

    R1.20 (PSI)

    WP304 200 deg-F Weld:

    ER308/308L Nozzle: SA508 CL.2A 0° I 2.25 I Long B-D A1R19 Shell: SA533 14" I 3.1 "

    2485 psig 45° I 2.25 I Shear 74.7%

    680 deg-F B3.110 (ISi)

    Gr.A CL.2 60° I 2.25 I Shear Weld: E9018 Nozzle: SA508 CL.2A 0° I 2.25 I Long B-D A1R19 Shell: SA533 6" I 3.1" 2485 psig 45° I 2.25 I Shear 68.7%

    B3.110 (ISi)

    Gr.A CL.2 680 deg-F 60° I 2.25 I Shear Weld: E9018 Appendix VIII Remarks Qualified Exam Examination was limited due to valve configuration and one-sided exam.

    Yes (Reference 1, Attachment 2, Pages 13 and 14)

    Examination Results - No recordable Indications.

    Examination limited in the "w" dimension of 6.0" at 290° due to proximity of heater penetration tubes.

    No (Attachment 2, Pages 1 - 5)

    Examination Results - No recordable Indications.

    Examination limited due to nozzle configuration.

    No (Attachment 2, Pages 6 - 10)

    Examination Results - No recordable Indications.

    Reference 1. Letter from D. Murray (Exelon Generation Company, LLC) to U.S. NRC, "Relief Request Associated with the Third Ten-Year lnservice Inspection Program Interval," dated August 27, 2019 (ML19239A156)

    Note: The following systems and their abbreviations are listed here: Auxiliary Feedwater (AF), Chemical and Volume Control System (CV), Pressurizer (RY), Feedwater (FW), Reactor Coolant (RC), Safety Injection (SI)

    Page 2 of 6

    Exam Exam Weld Requirements Category/

    Component ID Description (Figure No.)

    Item (System) and Method Number Elbow-to-IWC-2500-7(a)

    R-A 2Sl-39-11 Valve Weld Volumetric R1.20 (SI)

    (UT)

    Valve-to-Pipe IWC-2500-7(a)

    R-A 2Sl-39-11A Weld Volumetric R1.20 (SI)

    (UT)

    Elbow-to-IWC-2500-7(a)

    R-A 2Sl-39-28 Valve Weld Volumetric R1.20 (SI)

    (UT)

    Valve-to-Pipe IWC-2500-7(a)

    R-A 2Sl-39-28A Weld Volumetric R1.20 (SI)

    (UT)

    Pipe-to-Valve IWC-2500-7(a)

    R-A 2Sl-39-28B Weld Volumetric R1.20 (SI)

    (UT)

    Nozzle N4B-IWB-2500-7 2PZR to-PZR Shell B-D Volumetric N4B Weld 83.110 (RY)

    (UT)

    ATTACHMENT 7 Corrected Tables 13R-18.1 and 13R-18.2 Table 13R-18.2 Braidwood, Unit 2 List of Components with Limited Examination Coverage Normal Operating Outage Material of Diameter I Exam Angle/

    Actual Conditions Examined Construction Thickness (Pressure I Frequency I Mode Coverage Temperature)

    Elbow: SA403 TP304 o* I 4.00 I Long A2R16 Valve: SA479 2485 psig 4" I 0.531" 45* I 2.25 I Shear 50.0%

    (PSI)

    TP316 176 deg-F Weld:

    60° I 2.00 I Long.

    ER308/308L Valve: SA479 TP316 o* I 4.00 I Long A2R16 Pipe: SA376 2485 psig TP304 4" I 0.531" 176 deg-F 45* I 2.25 I Shear 50.0%

    (PSI)

    Weld:

    60° I 2.00 I Long.

    ER308/308L Elbow: SA403 o* I 4.00 I Long TP304 Valve: SA479 2485 psig 45* I 2.25 I Shear A2R16 4" I 0.531" 60° I 2.25 I Shear 50.0%

    (PSI)

    TP316 176 deg-F Weld:

    70° I 2.25 I Shear ER308/308L 60° I 2.00 I Long.

    Valve: SA479 TP316 o* I 4.00 I Long A2R16 Pipe: SA376 2485 psig TP304 4" I 0.531" 176 deg-F 45* I 2.25 I Shear 50.0%

    (PSI)

    Weld:

    60° I 2.00 I Long.

    ER308/308L Pipe: SA376 TP304 o* I 4.00 I Long A2R16 Valve: SA479 2485 psig 45* I 2.25 I Shear 50.0%

    TP316 4" I 0.531" 176 deg-F 60° I 2.25 I Shear (PSI)

    Weld:

    60° I 2.00 I Long.

    ER308/308L Nozzle: SA508 CL.2A A2R17 Shell: SA533 91.5" I 2485 psig 45* I 2.25 I Shear 88.5%

    2.0625" 680 deg-F o* I 2.25 I Long (ISi)

    Gr.A CL.2 Weld:

    E9018 Appendix VIII Remarks Qualified Exam Examination was limited due to valve configuration and one-sided exam.

    (Reference 1, Attachment 3, Yes Pages 2 and 3)

    Examination Results - No recordable Indications.

    Examination was limited due to valve configuration and one-sided exam.

    (Reference 1, Attachment 3, Yes Pages 4 and 5)

    Examination Results - No recordable Indications.

    Examination was limited due to valve configuration and one-sided exam.

    (Reference 1, Attachment 3, Yes Pages 6 and 7)

    Examination Results - Inside surface geometry indication.

    Examination was limited due to valve configuration and one-sided exam.

    (Reference 1, Attachment 3, Yes Pages 8 and 9)

    Examination Results - No recordable Indications.

    Examination was limited due to valve configuration and one-sided exam.

    Yes (Reference 1, Attachment 3, Pages 10 and 11)

    Examination Results - Root geometry indication.

    Examination was limited due to nozzle configuration and one-sided exam.

    No (Attachment 2, Pages 14

    • 17)

    Examination Results - No recordable Indications.

    Reference 1. Letter from D. Murray (Exelon Generation Company, LLC) to U.S. NRC, "Relief Request Associated with the Third Ten-Year lnservice Inspection Program Interval," dated August 27, 2019 (ML19239A156)

    Note: The following systems and their abbreviations are listed here: Auxiliary Feedwater (AF), Chemical and Volume Control System (CV), Pressurizer (RY), Feedwater (FW), Reactor Coolant (RC), Safety Injection (SI)

    Page 3 of 6

    Exam Exam Weld Component ID Description Requirements Category/

    (System)

    (Figure No.)

    Item and Method Number Nozzle N4C-2PZR to-PZR Shell IWB-2500-7 B-D N4C Weld Volumetric B3.110 (UT)

    (RY)

    Elbow-to-SG 2RC01BAAF IWC-2500-7(a)

    R-A 2FW-09-25 Nozzle Weld Volumetric R1.11 (FW)

    (UT)

    Nozzle N1-IWB-2500-7 2PZR-01-N1 to-PZR Shell Volumetric B-D Weld (UT)

    B3.110 (RY)

    Primary Nozzle Inner IWB-2500-7 2SG Radius Volumetric B-D SGN-01A B3.140 Section (UT)

    (RC)

    Tubesheet-2SG to-Barrel IWC-2500-2 C-A Volumetric SGC-02 Weld (UT)

    C1.30 (RC)

    ATTACHMENT 7 Corrected Tables 13R-18.1 and 13R-18.2 Table 13R-18.2 Braidwood, Unit 2 List of Components with Limited Examination Coverage Normal Operating Outage Material of Diameter I Conditions Exam Angle/

    Actual Examined Construction Thickness (Pressure I Frequency I Mode Coverage Temperature)

    Nozzle: SA508 A2R17 CL.2A 91.5" I 2485 psig 45* I 2.25 I Shear (ISi)

    Shell: SA533 2.0625" 680 deg-F o* / 2.25 / Long 88.5%

    Gr.A CL.2 Weld: E9018 Elbow: SA234 A2R18 Gr.WPB 1185 psig 45* I 5.00 I Shear (ISi)

    Nozzle: SA508 6" I 0.719" 567 deg-F 60° I 5.00 I Shear 87.3%

    CL.2A 70* I 5.00 I Shear Nozzle: SA508 CL.2A A2R19 Shell: SA533 26.10" I 2485 psig 45* I 2.25 I Shear 59.2%

    (ISi)

    Gr.A CL.2 2.5625" 680 deg-F 60° I 2.25 I Shear Weld: E9018 A2R19 SA216 29" I 2485 psig 33* / 2.25 / Long 85.0%

    (ISi)

    GrWCC 3.1875" 680 deg-F Tubesheet:

    A2R20 SA508 CL.2A 11.3' I 2485 psig o* I 2.25 1 Long Barrel: SA533 45* 12.25 1 Shear 88.4%

    (ISi)

    GR.A CL.2 3.3125" 680 deg-F 60° I 2.25 I Shear Weld: E8018-C3 Appendix VIII Remarks Qualified Exam Examination was limited due to nozzle configuration and one-sided exam.

    No (Attachment 2, Pages 18 - 21)

    Examination Results - No recordable Indications.

    Examination was limited due to nozzle configuration.

    Yes (Attachment 6, Page 67-71)

    Examination Results - No recordable Indications.

    Examination was limited due to nozzle configuration and the proximity of heater penetration tubes. Coverage plot No taken from NDE Data Sheet A2R13-UT-025.

    (Attachment 2, Pages 11 - 13)

    Examination Results - No recordable Indications.

    Examination was limited due to a permanent structure for 30" out of the No total 205".

    (Attachment 3, Pages 1 and 2)

    Examination Results - No recordable Indications.

    Examination was limited due to component configuration.

    No (Attachment 4, Pages 1 - 5)

    Examination Results - No recordable Indications.

    Reference 1. Letter from D. Murray (Exelon Generation Company, LLC) to U.S. NRC, "Relief Request Associated with the Third Ten-Year lnservice Inspection Program Interval," dated August 27, 2019 (ML19239A156)

    Note: The following systems and their abbreviations are listed here: Auxiliary Feedwater (AF), Chemical and Volume Control System (CV), Pressurizer (RY), Feedwater (FW), Reactor Coolant (RC), Safety Injection (SI)

    Page 4 of 6

    Exam Exam Weld Component ID Description Requirements Category/

    (System)

    (Figure No.)

    Item and Method Number 2AF-03-23 Elbow-to-IWC-2500-7(a)

    R-A Flange Weld Volumetric (FW-1)

    (AF)

    (UT)

    R1.20 Flange-to-IWC-2500-7(a) 2AF-03-24 Elbow Weld Volumetric R-A (FW-2)

    (AF)

    (UT)

    R1.20 Elbow-to-IWC-2500-7(a) 2AF-04-20 Flange Weld Volumetric R-A (FW-3)

    (AF)

    (UT)

    R1.20 Flange-to-IWC-2500-7(a) 2AF-04-21 Elbow Weld Volumetric R-A (FW-4)

    (AF)

    (UT)

    R1.20 2AF-02-23 Elbow-to-IWC-2500-7(a)

    R-A Flange Weld Volumetric (FW-1)

    (AF)

    (UT)

    R1.20 Flange-to-IWC-2500-7(a) 2AF-02-24 Elbow Weld Volumetric R-A (FW-2)

    (AF)

    (UT)

    R1.20 ATTACHMENT 7 Corrected Tables 13R-18.1 and 13R-18.2 Table 13R-18.2 Braidwood, Unit 2 List of Components with Limited Examination Coverage Normal Operating Outage Material of Diameter I Conditions Exam Angle/

    Actual Examined Construction Thickness (Pressure I Frequency I Mode Coverage Temperature)

    Elbow: SA234 2015 Gr.WPB 1185 psig 45* I 5.00 I Shear 4" I 0.337" 60° I 5.00 I Shear 87%

    (PSI)

    Flange: SA105 100 deg-F 70° I 5.00 I Shear Weld: ER70S-2 Flange: SA105 45* I 5.00 I Shear 2015 Elbow: SA234 4" I 0.337" 1185 psig 60° I 5.00 I Shear 87%

    (PSI)

    Gr.WPB 100 deg-F 70° I 5.00 I Shear Weld: ER70S-2 Elbow: SA234 45* I 5.00 I Shear 2015 Gr.WPB 4" I 0.337" 1185 psig 60° I 5.00 I Shear 88%

    (PSI)

    Flange: SA105 100 deg-F 70° I 5.00 I Shear Weld: ER70S-2 Flange: SA105 45* I 5.00 I Shear 2015 Elbow: SA234 4" I 0.337" 1185 psig 60° I 5.00 I Shear 88%

    (PSI)

    Gr.WPB 100 deg-F 70° I 5.00 I Shear Weld: ER70S-2 Elbow: SA234 2015 Gr.WPB 1185 psig 45* I 5.00 I Shear 4" I 0.337" 60° I 5.00 I Shear 90%

    (PSI)

    Flange: SA 105 100 deg-F 70° I 5.00 I Shear Weld: ER70S-2 Flange: SA 105 45* I 5.00 I Shear 2015 Elbow: SA234 4" I 0.337" 1185 psig 60° I 5.00 I Shear 90%

    (PSI)

    Gr.WPB 100 deg-F 70° I 5.00 I Shear Weld: ER70S-2 Appendix VIII Remarks Qualified Exam Examination was limited due to component configuration.

    Yes (Attachment 6, Pages 23 - 28)

    Examination Results - Root geometry indication.

    Examination was limited due to component configuration.

    Yes (Attachment 6, Pages 29 - 34)

    Examination Results - Root geometry indication.

    Examination was limited due to component configuration.

    Yes (Attachment 6, Pages 35 - 40)

    Examination Results - Root geometry indication, inside surface mismatch geometry indication.

    Examination was limited due to component configuration.

    Yes (Attachment 6, Pages 41 - 46)

    Examination Results - Root geometry indication, inside surface mismatch geometry indication.

    Examination was limited due to component configuration.

    Yes (Attachment 6, Pages 13 - 16)

    Examination Results - No recordable Indications.

    Examination was limited due to component configuration.

    Yes (Attachment 6, Pages 17 - 22)

    Examination Results - Root geometry indication.

    Reference 1. Letter from D. Murray (Exelon Generation Company, LLC) to U.S. NRC, "Relief Request Associated with the Third Ten-Year lnservice Inspection Program Interval," dated August 27, 2019 (ML19239A156)

    Note: The following systems and their abbreviations are listed here: Auxiliary Feedwater (AF), Chemical and Volume Control System (CV), Pressurizer (RY), Feedwater (FW), Reactor Coolant (RC), Safety Injection (SI)

    Page 5 of 6

    Exam Exam Weld Description Requirements Category/

    Component ID (Figure No.)

    Item (System) and Method Number 2AF-01-24 Elbow-to-IWC-2500-7(a)

    R-A Flange Weld Volumetric (FW-3)

    R1.20 (AF)

    (UT)

    IWC-2500-7(a) 2AF-01-25 Flange-to-R-A Elbow Weld Volumetric (FW-4)

    R1.20 (AF)

    (UT)

    Valve-to-Tee IWC-2500-7(a)

    R-A 2CV-21-58 Weld Volumetric R1.20 (FW-1)

    (CV)

    (UT)

    Tee-to-Pipe IWC-2500-7(a)

    R-A 2CV-21-57 Weld Volumetric R1.20 (FW-2)

    (CV)

    (UT)

    Pipe-to-Tee IWC-2500-7(a)

    R-A 2CV-21-56 Weld Volumetric R1.20 (FW-2)

    (CV)

    (UT)

    ATTACHMENT 7 Corrected Tables 13R-18.1 and 13R-18.2 Table 13R-18.2 Braidwood, Unit 2 List of Components with Limited Examination Coverage Normal Operating Exam Angle/

    Actual Outage Material of Diameter I Conditions Frequency I Mode Coverage Examined Construction Thickness (Pressure I Temperature)

    Elbow: SA234 45* I 5.00 I Shear 2015 Gr.WPB 4" I 0.337" 1185 psig 60° I 5.00 I Shear 90%

    Flange: SA105 100 deg-F (PSI) 70° I 5.00 I Shear Weld: ER70S-2 Flange: SA105 45* I 5.00 I Shear 2015 Elbow: SA234 4" I 0.337" 1185 psig 60° I 5.00 I Shear 89%

    Gr.WPB 100 deg-F (PSI) 70° I 5.00 I Shear Weld: ER70S-2 Valve: SA351 Gr.CF8M 45* 12.25 1 Shear 2015 Tee: SA403 2485 psig 60° I 2.25 I Shear 20.7%

    Gr.WP304 4" I 0.531 "

    200 deg-F 70° 12.25 1 Shear (PSI)

    Weld:

    60° I 2.00 I Long ER308/308L Tee: SA403 Gr.WP304 45* 12.25 1 Shear 2015 Pipe: SA312 2485 psig 60° I 2.25 I Shear 83.3%

    4" I 0.531 "

    (PSI)

    TP304 200 deg-F 70° 12.25 1 Shear Weld:

    60° I 2.00 I Long ER308/308L Pipe: SA312 TP304 45* 12.25 1 Shear 2015 Tee: SA403 4" I 0.531 "

    2485 psig 60° 12.25 1 Shear 83.3%

    (PSI)

    Gr.WP304 200 deg-F 70° I 2.25 I Shear Weld:

    60° 12.00 I Long ER308/308L Appendix VIII Remarks Qualified Exam Examination was limited due to component configuration.

    Yes (Attachment 6, Pages 1 - 6)

    Examination Results - Root geometry indication.

    Examination was limited due to component configuration.

    Yes (Attachment 6, Pages 7 - 12)

    Examination Results - Root geometry indication.

    Examination was limited due to component configuration.

    Yes (Attachment 6, Pages 61 - 66)

    Examination Results - No recordable Indications.

    Examination was limited due to component configuration.

    Yes (Attachment 6, Pages 53 - 60)

    Examination Results - Root geometry indication.

    Examination was limited due to component configuration.

    Yes (Attachment 6, Pages 47 - 52)

    Examination Results - No recordable Indications.

    Reference 1. Letter from D. Murray (Exelon Generation Company, LLC) to U.S. NRC, "Relief Request Associated with the Third Ten-Year lnservice Inspection Program Interval," dated August 27, 2019 (ML19239A156)

    Note: The following systems and their abbreviations are listed here: Auxiliary Feedwater (AF), Chemical and Volume Control System (CV), Pressurizer (RY), Feedwater (FW), Reactor Coolant (RC), Safety Injection (SI)

    Page 6 of 6