05000259/LER-1981-025-01, /01T-0:on 810521,during Scheduled Refueling Outage Three Main Steam Relief Valves Failed to Actuate W/Required 1% of Set Pressure During Bench Test.Cause Unknown.Valves Adjusted & Correct Valve Operation Verified

From kanterella
(Redirected from ML20004D668)
Jump to navigation Jump to search
/01T-0:on 810521,during Scheduled Refueling Outage Three Main Steam Relief Valves Failed to Actuate W/Required 1% of Set Pressure During Bench Test.Cause Unknown.Valves Adjusted & Correct Valve Operation Verified
ML20004D668
Person / Time
Site: Browns Ferry 
Issue date: 06/03/1981
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20004D662 List:
References
LER-81-025-01T, LER-81-25-1T, NUDOCS 8106090634
Download: ML20004D668 (2)


LER-1981-025, /01T-0:on 810521,during Scheduled Refueling Outage Three Main Steam Relief Valves Failed to Actuate W/Required 1% of Set Pressure During Bench Test.Cause Unknown.Valves Adjusted & Correct Valve Operation Verified
Event date:
Report date:
2591981025R01 - NRC Website

text

e a d e a 1 I H I P.1 J4.I.

U /D LICEN:

r. VENT Heew ;

p.

CCNillOI RLOCK.[

l l

l l

lh (PLE ASE PRINT OR TYPE ALL REoutRED INFoRMATioN) j a

i h. LJ LAI tl Bl al FI 1101 0101 -10101010101 - 1010 IGI 4 I i I i I i l i 101 I

I@

l L IF.F Pa%E t C()(1[

14

?S LICENSE Nuvat n 15

?G LICENSE rvrE Jo

%d C A I sa t # }r < * ?

{53]

UI,[,j lL @ l0 ]5 10 l0 10 l2 l5 l9 @l O l S l 2 l 1l 8 l 1 @l Oi 6l 0l 3l 8 l 1]@

evt.;rOBCHI HON At O PROB A L C NS ENCES 3 of the main i

[M] [With the unit in cold shuts'own during a scheduled refueling outage, pg l_ steam relie f valves failed to actuate within the required 1% of set pressure during g g l bench test.

(T.S. 4.6.D.1)

There was no danger to the health or safety of the

]

I

Previous similar events

BFRO-50-260/

l [7,E [_public, and no signiiicant chain of events.

80040; 296/80054.

j, g g i

EOI l

i3 m L_

MO

' 9 COMP VALVE i

3YS r E ?.1

CAUSE

CAUSE CCOE CCOE SUSCDCE COMPONENT CODE SUSCOCE SUSCOCE b.id

]c Ic I@ l Ej@ l B l@ lV l A lL lV lE lX l@ l Jl@ W @

4 l9

  1. f 72 IJ 18 i )

.O 4

9fuutNilAt OCCO*t Flf P;Cr nErnnT n EVISION me '/ 5 N r a f M t nFPont NO CODE fvpf Na 9,"g,9 igg 18Ill I-I 1012l51 lM i 0l ll ITI l_l 10 l

' "'c ";

_.' s 22 n

24 26 23

  • )

30 1'

32 M:rinN reiruns EFrfCY LHuTDOWN A TT ACHV E N T N P ft O-4 PRIME COMP.

CouPONENT T Av ers ts. f ir 5N 04 Pt AN r METHCD HUQ 't $

SUBMITTED ScRM DUB.

SUPPU E n MANUFACTupFn l E lgl'4X lg l35Z lg lJGZ lg l30l0j0 l g g [Y g lL l g lT l0 l2 l0 lq 3

40 41 47 43 44 di CAUSE DESCnlPTION AND CORRECTIVE ACTIONS j,inj l The cause of the event is unknown. The set pressure was reset and the proper l

g ij ; operation verified. Target Rock Model 7567F-100, cast steel, size 6 x 10, 7,;-) ; valve serial numbers 1017, 1070, and 1060. The cause is being investigated with Present evaluation indicates no safety problems posed by this l

g [the manufacturer.

1ilil [ event.

m 4

i ornen srAru-h Ns#"[vS8v#

'ib '?

C ocovEnv cE=mpricN

mat..

l NA l

lBl@lObservedduringbenchtest.

l2 l-l[_Hj(3) l0l0l0l@l

. 4rcor A2E@

A.,ou.,r os AC nvirv @ l

,,,,,, r e >

(OC AricN oe net:

n,.tc a,,r ru.,sE NA l

NA l

LLlL!l zl O LzJ@l 48) 44 4%

If3 11

.....mnm. n Pmen u 80 f ? 'il f I t

'yPF fi( St.f;t P T I O N j

liJ:ll0l0lOj@[Zj@[

NA m,

Pre t*'ONNt I of;jum[

NUP Tl it UF #).TitPIl# N '

l J

I' I Il0101Ol@l NA Itf I r

't 11 1/

J tde s6 ( til f e AM Af.I l e s i M 11 I T 's' 4 g/

NA d

i l

l "l

t 4'.s ItlP f it eq

[.T] l Zj@l m

1. i ! I Ni@l NA l

ll lll,!!!] Il l g% F V "4. 99 tP f i*)N r, a r,o mi 4

9 m

PHONE N A*.'E OF T'HE P AREH

.8106 09 n bb

~

o a

Tennessee Valley Authority Foru BF-17 Browns Ferry Muclen: Plant BF 15.2 3/24/81 LF.R SUPPLEMENTAL INFORMATION DFIto-T.O.

259 / 81025 Technical Specification involved 4.6.D.1 Reported Under Technical Specification ___ _

6.7.2.A.1 Date of Occurrence 5/21/81 Time of Occurrence 1430 __ Unit 1

Identification and Descripntion of Occurrence:

During a bench test with the unit in a scheduled refueling outage, 3 main steam relief valves f ailed to actuate within the required 1% of set pressure. They are as follows:

, VALVE SN SET PRESSURE AS FOUND 1017 1115 1020 1060

  • 1105 1118 1060
  • 1105 11'.1 1060
  • 1105 1119 1060
  • 1105 1114 1070 1115 1154
  • valve SN 1060 tested four times Conditions prior to Occurrence Unit I refueling outage Unit 2 at 100%

Unit 3 at 100%

Action specified in the Technical Specification Surveillance Requirements met due to inoperable equipment. Describe NA Apparent Cause of Occurrence Unknown At.inlyyic_ of Occurrence:

=se of There was no danger to the health or safety of the public, no rct activity, no damage to the plant or equipment, and no resulting #.g111ficant chain of events.

Corr _cetive Action:

The cause The valves were adjusted and the correct valve operation verified.

is being investigated by the manufacturer.

Failure Data:

BFRO-50-260/80040; 296/80054.

  • lt e t en tior. :

Period - Lifetime; Responsibility - Document Control Supervisor

  • Revision :

[

P00R ORl3ll\\il y,

,._s.