05000259/LER-1980-082-01, /01T-0:on 801031,drywell Pressure Transmitters 1-PT-64-50 & 1-PT-64-67 Were Not Qualified for Radiation Environ Following Loca,Per IE Bulletin 79-01B Requirements. Cause Not Stated.Models Gemac 552 & 556 Replaced

From kanterella
(Redirected from ML19343A816)
Jump to navigation Jump to search
/01T-0:on 801031,drywell Pressure Transmitters 1-PT-64-50 & 1-PT-64-67 Were Not Qualified for Radiation Environ Following Loca,Per IE Bulletin 79-01B Requirements. Cause Not Stated.Models Gemac 552 & 556 Replaced
ML19343A816
Person / Time
Site: Browns Ferry 
Issue date: 11/12/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19343A815 List:
References
IEB-79-01B, IEB-79-1B, LER-80-082-01T, LER-80-82-1T, NUDOCS 8011210548
Download: ML19343A816 (2)


LER-1980-082, /01T-0:on 801031,drywell Pressure Transmitters 1-PT-64-50 & 1-PT-64-67 Were Not Qualified for Radiation Environ Following Loca,Per IE Bulletin 79-01B Requirements. Cause Not Stated.Models Gemac 552 & 556 Replaced
Event date:
Report date:
2591980082R01 - NRC Website

text

s.

NRC FORM M4 u. ex %. EAR REftMLA10HY CoMMtwu-LICENSEE EVENT REPORT Q CONTROL BLOCK: l l l

l l

1 Ih (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATIONI (j

1 6

['o"Til I A I L i a I a l F I 11@16010 l-1010101010 l-1010 l@l 41 11 11 11 il@

I l@

7 8 9 LICENSEE CODE i4 LICENSE NUMSER 25 26 LICENSE TYPE JO

$ 7 C A F 58 CON'T 37RCE lX @l0IS10I0101215 19 @ ll !0 l3 11 18 10 @ l 11 11 il 21 8l Ol @

o 1 7

8 60 68 DOCKET NUM8ER GS 69 EVENT QATE le 75 REPCHTDATE AC EVENT DESCRIPTION AND PRO 8ABLE CONSEQUENCES h Q l Drywell pressure transmitters 1-PT-64-50 and 1-PT-64-67 were not qualified for l radiation environment following LOCA as defined in NRC Bulletin 79-01B.

Notification io i3l t o ini l received 10/31/80 at 1600.

(T.S. 3.2.F).'

There was no effect on the public health [TTs"] g or safety. There is no redundant system. Previous events: None.

o 6 l Io I7I I Lo La.j i

E

    1. iECo ' su'aC$ot COMPONENT CoOf SUS
  • EoI:'E O

SU E

Lol.S_]

I Il cl@ W@ L3_j @ l 11 si s I ml = l 111@ L7 j@ L.y @

7 8

9 to 1

12 13 18 is 20 SEcufNTIAL OCCURRENCE REPOHT R E. tS'ON LE R Ro EVENTvEAR REPORT No.

CoOE TYPE NO

@,afgr 18101 l-j 1018121 L<J 10 1 t I I TI l-l LoJ 21 22 23 24 26 27 28 29 30 Ji

'2 N AC 0 ONP NT FET HOUR $

$9 BTT POR b 8.

$U L MANI I Tl 8

L J@LZ J@

l zl@

LzJ@

l 0101010I II J@

LxJ@

Ls.JO I c I O I a i o-33 J4 JS 36 13 40 43 42 43 44 CAUSE OFSCRIPTION AND CCRRECTivE ACTIONS lt t o l l Transmitter models GEMAC 552 and 556 were replaced.

PT-64-50 was replaced on 10/31/80 ITTT1 I and PT-64-67 was replaced on 11/4/80 with Foxboro Model EllCM. The two transmitters Ii12i Ivere not qualified to meet the environmental conditions of a LOCA.

L,.t.Laj i I i 14') 1 7

6 9 ST s

% power OT>.ER STATUS 15 Rv DiSCGVERY DESCHi* Tion NA l

g gl Design Review I1 l' I d@ l 0 l 9 l 8 l@l

~

ColrENT AucuNTor ACTiviTv @ l LcCATies or aELEAst @

Activity atLEAsEo of REttAsE NA l

NA M LZj @ [,zJgl 7

8 9 to 1

44 45 PEH%ONNEL EXPO $URE$

NOVSER TYPE

DESCRIPTION

Fi ITI I 01010 l@l Z l@l NA PERSONNE L INJU IES

DESCRIPTION

1 01Nuu0ER10 l@l NA i a 7

i, i2 otsCR PT$oN T PE l zi@l NA i 9 7

e 9 to itSUE @ DESCRIPTION [N

l NA l

l l l l l l l l l t I l_

2 o 68 G9 7

8 9 in 80112105f7 PHONE:

NAME OF PREPAREH

Tennessee Valley Authority Form BF.17 Browns Ferry Nuclear Plant BF 15.'2 1/10/79 LER SUPPLEMENTAL INFORMATION BFRO 259 / 8082 Technical Specification Involved 3.2.F p

Reported Under Technical Specification NRC Bulletin 79-OlB Date of Occurrence 10/31/80 Time of Occurrence 1600 Unit 1

[

Identification and Description of Occurrence:

Drywell pressure transmitters 1-PT-64-50.and 1-PT-64-67 were not qualified for

~

radiation envircnment following LOCA as defined in NRC Bulletin 79-01B.

Conditions ' Prior to Occurrence:

Unit 1 at 98% power Unit 2 refueling Unit 3 at 96 power Action specified in the Technical Specification Surveillance Requirements met due to inoperable equipment. Describe.

None Apparent Cause of Occurrence:

Transmitters not qualified to meet LOCA environmental conditions as defined-by NRC Bulletin 79-01B.

Analysis of Occurrence:

There has been no effect on the public health or safety, no release of activity, no damage to plant equipment and no significant chain of events.

Corrective Action

Replaced transmitters'. Transmitters were also identified and replaced on Units 2 and 3.

Failure Data:

Jane

  • Retention:

eriod - Lifetime; Responsibility - Administrative Supervisor j

  • Revision:

W